MP 277 - Service, Support Download

Transcript
Configuring the device
6.8 Setting the uninterruptible power supply
6.8
Setting the uninterruptible power supply
UPS monitoring is an option you load as an add-on with ProSave.
A UPS ensures that the HMI device is shut down in a controlled manner after a buffer time in
the event of a power failure. This avoids the loss of data. The following uninterruptible power
supplies are supported:
● SITOP DC UPS modules as of a rated power value of 6 A, e.g. 6EP1931-2DC42
Configure the USB port for UPS monitoring.
Requirement
● The UPS is connected to the 24 V input and a USB port.
● You have opened the "Configuration" tab in the "UPS Properties" dialog box with the
"UPS" icon.
①
②
③
④
Text box for the time after which the "Battery mode activated" message is displayed
Check box for enabling battery mode
Text box for the time after which the "Faulty port" message is displayed
Check box for the "Faulty port" message
Procedure
1. If you want to enable battery mode, activate the "Battery mode" check box.
2. Enter the time for terminating applications in the "min" and "s" text boxes.
You will receive a message when UPS takes effect. Applications such as HMI Runtime
and WinAC MP are then terminated depending on the time entered.
3. If the port to which the UPS is connected is faulty and you therefore want to receive a
message, activate the "Port disturbed" check box.
4. Select the message you want from the list box.
5. Enter the time after which the "Faulty port" message is displayed in the "min" and "s" text
boxes.
Port monitoring for the UPS is set.
MP 277
104
Operating Instructions, 07/2014, A5E02479740-02
Similar
MP 277 - Service, Support
MP 277 - Service, Support
WirelessKey PROFESSIONAL manual
WirelessKey PROFESSIONAL manual
Descarga  - Service, Support
Descarga - Service, Support
X5 line c - Ascon S.p.A.
X5 line c - Ascon S.p.A.
"user manual"
Visualization of Dispatching Strategies
Visualization of Dispatching Strategies
TP 277, OP 277 (WinCC flexible) - Service, Support
TP 277, OP 277 (WinCC flexible) - Service, Support
Operating Instructions HMI device MP 177 (WinCC flexible)
Operating Instructions HMI device MP 177 (WinCC flexible)
Catalog ST 80 / ST PC 2010
Catalog ST 80 / ST PC 2010
SIMATIC HMI HMI Device TP 177A, TP 177B, OP
SIMATIC HMI HMI Device TP 177A, TP 177B, OP
900 kB - Nexus Marine
900 kB - Nexus Marine
- Murdoch Research Repository
- Murdoch Research Repository
X1 line c
X1 line c
"user manual"
WinAC RTX ODK User Manual - Service, Support
WinAC RTX ODK User Manual - Service, Support
RPX Lite (RPXL_CW), User Manual
RPX Lite (RPXL_CW), User Manual
Simatic S7-200
Simatic S7-200
SIMATIC HMI HMI device MP 377 (WinCC flexible)
SIMATIC HMI HMI device MP 377 (WinCC flexible)
Operator Control and Monitoring Devices
Operator Control and Monitoring Devices
NETLink PRO Compact Handbuch
NETLink PRO Compact Handbuch
Mobile Panel 277 RO - Service, Support
Mobile Panel 277 RO - Service, Support
KT4H Temperature Controller
KT4H Temperature Controller