Commissioning a project
7.7 Updating the operating system
7.7.2
Updating the Operating System using ProSave
Requirement
● The HMI device is connected to a PC on which ProSave is installed.
● When updating the operating system without reset to factory settings only:
The data channel is configured on the HMI device.
Procedure
Proceed as follows:
1. When updating the operating system with reset to factory settings only:
Switch off power to the HMI device.
2. Go to the Windows Start menu and start ProSave on the PC.
3. Select the HMI device type in the "General" tab.
4. Select the type of connection between the HMI device and the PC, then set the
connection parameters.
5. Select the "OS Update" tab.
6. Select whether to update the operating system with or without restoring the factory
settings by setting the "Reset to factory settings" check box accordingly.
7. Select the HMI device image file "*.img" under "Image path".
The HMI device image files are available under "WinCC flexible Images" in the
WinCC flexible installation folder or on the WinCC flexible installation CD.
The output area provides information on the version of the successfully opened HMI
device image file.
8. When updating without reset to the factory settings only:
Set "Transfer" mode on the HMI device.
If automatic transfer mode is enabled on the HMI device, the device automatically sets
"Transfer" mode when an update is initiated.
9. Select "Update OS" on the PC to run the operating system update.
10. When updating with reset to the factory settings only:
Switch on the power supply to the HMI device.
11. Follow the instructions in ProSave.
Result
A progress bar indicates the progress of the operating system update.
A message is displayed when the operating system update is successfully completed.
The HMI device no longer contains any project data.
See also
Overview (Page 152)
Configuring the data channel (Page 109)
Operating modes (Page 134)
Data Transmission Options (Page 136)
MP 277
Operating Instructions, 07/2014, A5E02479740-02
151
Similar
MP 277 - Service, Support
MP 277 - Service, Support
WirelessKey PROFESSIONAL manual
WirelessKey PROFESSIONAL manual
Descarga  - Service, Support
Descarga - Service, Support
X5 line c - Ascon S.p.A.
X5 line c - Ascon S.p.A.
"user manual"
Visualization of Dispatching Strategies
Visualization of Dispatching Strategies
TP 277, OP 277 (WinCC flexible) - Service, Support
TP 277, OP 277 (WinCC flexible) - Service, Support
Operating Instructions HMI device MP 177 (WinCC flexible)
Operating Instructions HMI device MP 177 (WinCC flexible)
Catalog ST 80 / ST PC 2010
Catalog ST 80 / ST PC 2010
SIMATIC HMI HMI Device TP 177A, TP 177B, OP
SIMATIC HMI HMI Device TP 177A, TP 177B, OP
900 kB - Nexus Marine
900 kB - Nexus Marine
- Murdoch Research Repository
- Murdoch Research Repository
X1 line c
X1 line c
"user manual"
WinAC RTX ODK User Manual - Service, Support
WinAC RTX ODK User Manual - Service, Support
RPX Lite (RPXL_CW), User Manual
RPX Lite (RPXL_CW), User Manual
Simatic S7-200
Simatic S7-200
SIMATIC HMI HMI device MP 377 (WinCC flexible)
SIMATIC HMI HMI device MP 377 (WinCC flexible)
Operator Control and Monitoring Devices
Operator Control and Monitoring Devices
NETLink PRO Compact Handbuch
NETLink PRO Compact Handbuch
Mobile Panel 277 RO - Service, Support
Mobile Panel 277 RO - Service, Support
KT4H Temperature Controller
KT4H Temperature Controller