MP 277 - Service, Support Download

Transcript
Configuring the device
6.2 Enabling and disabling SecureMode
6.2
Enabling and disabling SecureMode
SecureMode prevents unauthorized access to the desktop and the taskbar of the HMI
device. In SecureMode, all functions on the desktop and the taskbar of the HMI device are
locked.
Procedure
Enabling SecureMode
1. Assign a password in the Control Panel for the HMI device.
2. If no password has been assigned for the HMI device, double-click the following icon on
the desktop.
SecureMode is enabled. The text "secure mode" appears on the desktop.
Disabling SecureMode
1. If a password is assigned for the HMI device, then delete it.
2. If no password has been assigned for the HMI device, operate the "Taskbar" button once
in the Loader.
6.3
Control Panel
6.3.1
Overview
Control Panel of the HMI device
You can configure the following settings in the Control Panel of the HMI device:
● Date/time
● Screen saver
● Regional settings
● Transfer settings
● Network settings
● Delay time
● Password
MP 277
74