Download DeviceNet™ Netmeter DeviceNet NetMeter™

Transcript
DeviceNet™
NetMeter
DeviceNet NetMeter™
DeviceNet™ Netmeter
DeviceNet™
Specifications
• Diagnostic/troubleshooting tool
• Analyzes both power and bit stream information
• Hand held with simple user interface
Diagnostics
The DeviceNet NetMeter empowers
untrained personnel to diagnose and
• Empowers untrained
troubleshoot network installations
personnel to diagnose
quickly and easily, without risk.
and troubleshoot the
Completely passive on the network,
network quickly
POWER SUPPLY:
CONNECTORS:
and easily
the meter analyzes the data and
power lines on your DeviceNet net-
BAND RATES:
ANALOG ACCURACY
ANALOG RANGE:
• Simplifies network wide
work. In seconds, both network-wide
and device specific
and device-specific traffic as well as
information with easy
power monitoring information is
user interface for fast
captured and displayed on a simple,
diagnostics and
straightforward user interface. Auto
troubleshooting
Search checks bus errors, bus traffic,
• Certifies proper
bus power voltage, shield voltage,
operation of new
common mode voltage, CAN_H/L
DeviceNet installations
Differential, CAN_H and CAN_L
quickly
ANALOG SAMPLE RATE:
SIGNAL ERROR THRESHOLD:
TWO OPERATIONAL MODES OF USE
BUS LOAD MEASUREMENT:
BUS MESSAGE RATE
MEASUREMENT:
Electrician Mode (simple)
ERROR RATE MEASUREMENT:
Voltage and summarizes network
1.
PLUG IN AND SET NETMETER ROTARY SWITCH TO “AUTOSEARCH”
health with helpful troubleshooting
2.
IDENTIFY NETWORK HEALTH
– HAPPY FACE = HEALTHY
icons.
NETWORK 11 – 30V DC < 60mA
BATTERIES 2 X AA ALKALINE BATTERIES
6 HOURS OF OPERATION APPROX. 1 YEAR
DATA RETENTION
QTY (1) MICRO-MICRO CONNECTOR AND
QTY (1) MICRO-MINI
125K, 250K AND 500K (AUTO –DETECT)
BUS POWER ± 100mV, BUS SIGNAL ± 20mV
BUS POWER 0 TO 25V WITH
OVER/UNDER RANGE INDICATION
BUS SIGNAL -5 TO 10 WITH
OVER/UNDER RANGE INDICATION
BUS POWER 1 KHZ BUS SIGNAL IDEAL
SAMPLE PT±250 nS
PER DEVICENET SPEC FOR NETWORK
POWER
DETECTS BUS IDLE IN REAL TIME
DETECTS 100% OF INDIVIDUAL CAN
FRAMES IN REAL TIME
DETECTS 100% OF INDIVIDUAL ERROR
FRAMES IN REAL TIME
– NEUTRAL FACE = NOMINAL
– SAD FACE = FAULTY
3.
SCROLL THROUGH FAULTS. REFER TO
USER MANUAL TO LINK THESE FAULTS
TO MOST LIKELY NETWORK PROBLEMS
OR FREEZE AND LOCK SETTINGS FOR THE
PLANT CONTROL ENGINEER TO REVIEW
MODES
PRESENT MAXIMUM MINIMUM PEAKVALUE
TO-PEAK
NetMeter™ offers
• simple user interface
DeviceNet Expert Mode (advanced)
• great value proposition for the features
• passive on network, cannot create faults or bus errors on network through usage
1.
• links faults found to extensive diagnostic of cross-reference likely network fixes for fast real world troubleshooting
• generates statistics for troubleshooting intermittent faults
• high accuracy
• includes mating cordsets DND21A-M010 and DND22A-M010
• prevents downtime as it detects marginal conditions prior to them causing faults
2.
SCROLL THROUGH DEVICENET PARAMETERS FOR EACH ACTIVE
DEVICENET NODE (MAC ID)
– COMMUNICATION ERRORS (RATE, CUMULATIVE #)
– BANDWIDTH (% OF FULL USAGE)
– POWER SUPPLY AND SHIELD VOLTAGES
– DATA BIT QUALITY (DOMINANT, RECESSIVE, +, -, DIFFERENTIAL
VOLTAGE, CMV)
CHECK VALUES (BOTH NUMERIC AND ICONS)
– HAPPY FACE = WITHIN SPEC
70
PART NUMBER
DESCRIPTION
DN-MTR
NETMETER – MONITORS BITSTREAM
TRAFFIC; POWER LINES FOR DEVICENET
DN-MTR-BAG
CONVENIENCE BAG FOR
DEVICENET METER
1-877-268-3700 SALES AND SERVICES BY GROSS AUTOMATION
x
x
x
BUS
TRAFFIC
x
x
x
BUS PWR
VOLTAGE
x
x
x
SHIELD
VOLTAGE
x
x
x
COMMON
MODE
VOLTAGE
x
x
x
– SAD FACE = OUT OF LIMIT
CAN_H
VOLTAGE
x
x
x
REFER TO USER MANUAL TO LINK THESE FAULTS TO MOST
LIKELY NETWORK PROBLEMS
CAN_L
VOLTAGE
x
x
x
www.bradharrisionsales.com
x
x
CAN_H/L
DIFFERENTIAL
– NEUTRAL FACE = VERY CLOSE TO LIMIT
3.
BUS
ERROR
FA X 1 - 8 7 7 - 2 6 8 - 9 7 0 0
71