8.12 Project Security
8.12.4
User Logoff
Requirements
You have logged into the security system of the HMI device.
Procedure
You have the following options for logging off:
• You operate an operator control that was configured for logoff.
• You will be logged off automatically if you are not operating the project and if the logoff
time has been exceeded
You will also be automatically logged off if you enter an incorrect password.
Result
You are no longer logged into the project. In order to operate an operator control with
password protection, you must first log on again.
8.12.5
Creating Users
8.12.5.1
Creating Users with Touch Operation
Requirement
You have opened a screen containing the user view.
You have user management permission or you are the administrator.
Notice
The following characters cannot be used in passwords:
• Space character
• Special characters * ? . % / \ ' "
8-38
TP 277, OP 277 (WinCC flexible)
Operating Instructions, 09/2007, 6AV6691-1DH01-0AB0