Download Honeywell Precision Barometer HPB
Transcript
HPB Honeywell Precision Barometer HPB The Honeywell Precision Barometer (HPB) offers outstanding value to instrument builders requiring accurate and stable barometric measurements in real-world conditions. The HPB uses proven silicon sensor technology with microprocessor-based signal compensation, eliminating the need to insulate or temperature-regulate the barometer. The HPB has a pressure range of 500 to 1200 hPa. The HPA, intended for altimeter applications, provides a pressure range of 0 to 17.6 psia. APPLICATIONS: AWOS Weather Systems Remote Meteorological Stations Ocean Data Buoys Environmental Data Logging Secondary Air Data Altimeters Outstanding Value Small, Rugged Design ±0.4 hPa Accuracy From -40 to 85ºC FEATURES AND BENEFITS ISO-9001 ISO-14001 High Accuracy 0.4 hPa max from -40 to 85C 0.03% FS max from -40 to 85C Two-tiered accuracy including temperature errors over -40 to 85C Multiple Interface Options Interface, Plug-and-Play for your system requirements. Easy TTL – for lowest power consumption (33 milliwatts) – HPB, 0.4 hPa or 0.8 hPa; HPA, 0.03% or 0.06% FS Max. Simplifies System Design – there is no need to insulate, temperatureregulate or provide additional signal compensation. RS-232 – receives commands and sends data to a single serial port of a computer. RS-485 – up to 89 units can be connected to a two-wire multidrop bus. Proven Honeywell Technology and Reliable – Honeywell has been building the world’s highest Stable performance silicon pressure sensors for over thirty years. HPB SPECIFICATIONS CASE OUTLINE (1) Performance Specifications Total Error Band : (from -40 to 85ºC) HPB200: ±0.4 hPa maximum HPB100: ±0.8 hPa maximum HPA200: ±0.03% FS maximum HPA100: ±0.06% FS maximum Temperature: ±1ºC (at sensing element) Temperature Range: Operating -40 to 85ºC (-40 to 185ºF) Storage: -55 to 90ºC (-67 to 194ºF) Sample Rate(3): 8.33ms to 51.2 min Resolution: 0.0011% FS(4) Response Delay: (1000/update rate) +1ms, minimum 17ms Long Term Stability(6): HPB: 0.25 hPa max per year HPA: 0.02% FS max per year Mechanical Specifications Pressure Ranges: HPB: 500 to 1200 hPa (1 hPa = 1 mbar) HPA: 0 to 17.6 psia Pressure Units(3): atm, bar, cmwc, ftwc, hPa, inHg, inwc, kg/cm², KPa, mBar, mmHg, MPa, mwc, psi, user, Icom, pfs Media Compatibility: Suitable for non-condensing, non-corrosive, and non-combustible gases. Weight: 5 oz. (142 gm) without fittings Electrical Specifications Output: TTL, RS-232, RS-485 Power Requirements: TTL Supply Voltage: 6 to 26 VDC RS-232, RS-485 Supply Voltage: 5.5 to 30 VDC Operating Current: RS-232/RS-485: 17-30mA; TTL: 6-9 mA Baud Rate(3): 1200, 2400, 4800, 9600, 14400, 19200, 28800 Bus Addressing(3): Address up to 89 units. Environmental Features(2) Humidity Sensitivity: Negligible Acceleration Sensitivity: Negligible Mechanical Shock: 1500g, 0.5ms half sine Temp Shock: 24 1-hour cycles, -40 to 85ºC Vibration: 0.5in or 20G’s, 20Hz – 2K Hz (1) Accuracy is the sum of worst case linearity, repeatability, hysteresis, thermal effects and calibration errors from -40 to 85ºC. Calibration is traceable to NIST. (2) Mechanical Shock tested per MIL-STD-883D, M2002.3, Cond. B. Vibration tested per MIL-STD-883D, M2007.2, Cond. A. (3) User Configurable. (4) Best resolution obtained with PFS (percent full scale) pressure units. (5) Demonstration kit includes unit, power supply/data cable (120V), demonstration software, TTL-to-RS232 converter (TTL only), and user manual. (6) Beyond max. total error band when continuously powered at 25±10°C, <90%RH and 28 to 32 inHg atmospheric pressure. Pin# Signal Name 1 RS-232(TD)/RS-485(B) 2 RS-232(TD)/RS-485(A) 3 Case Ground 4 Common Ground(GND) 5 DC Power In(+) 6 N/C Pin # Signal Name 1 TTL XMIT 2 TTL RCV 3 Case Ground 4 Common Ground(GND) 5 DC Power In(+) 6 Power Control ORDERING INFORMATION Honeywell Precision Barometer APPLICATION TYPE HPB Barometer Application, 500 to 1200 hPa (1 hPa = 1 mbar) HPA Altimeter Application, 0 to 17.6 psia ACCURACY BAROMETER ALTIMETER 200 ±0.4 hPa max ±0.03% FS max 100 ±0.8 hPa max ±0.06% FS max PRESSURE CONNECTION W Brass barbed (1/8 inch ID tubing) X Brass SwagelokTM (1/8 inch female) R Brass barbed, right angle (1/8 inch ID tubing) F Filter (blocks debris) HPB 200 W OUTPUTS 2D RS-232 5D RS-485 TT TTL ELECTRICAL CONFIGURATION AND CONNECTION A 6-pin plastic connector OPTIONS A Demonstration Kit(5) (RS-232, TTL only) B Mating Connector (See Below) C Power Supply/Data Cable (RS-232, TTL with Option G only, See Below) G TTL to RS-232 Converter (TTL only) 2D A -B Power Control (TTL Only) Find out more For more information on Honeywell’s Precision Pressure Transducers visit us online at www.pressuresensing.com or contact us at 1-800-601-3099 (International: 1-602-365-3099). Customer Service Email: D&[email protected]. Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. Honeywell Honeywell International Inc. 12001 Highway 55 Plymouth, MN 55441 www.pressuresensing.com ADS-14181 July 2014 ©2012 Honeywell International Inc.