Transcript
Integrated
Blower/Battery
User Manual
Donning Personal Protective
Equipment (PPE)
Quick Loc
Belt
Filters
TM
Sentinel XL HP Clear Hood
Powered Air Purifying Respirator
(PAPR) System
1
Charge Battery Pack
4
A
A
A. Plug battery charger into socket
at back of the battery pack and
connect to an electrical outlet.
Charge battery pack for
approximately five hours before
use. The battery charger LED will
flash green when charging is
complete.
2
Prepare Filters for Use
A
Breathing
Hose
Check Air Flow
B
A. Ensure canisters are installed
on the blower. Switch blower
on. A short beep should sound.
Place flow meter in the blower’s
hose connector.
B. If the upper portion of the black
cone is above the indication line
on the flow meter, the system is
ready for use
5
A
Attach Breathing Hose
B
Hood
Battery
Charger
Flow
Meter
7
Donning Hood
A
B
C
D
A. Open Clear Hood opening.
B. Place over head.
C. Tuck inner skirts under Tyvek suit.
Zip Tyvek suit closed.
D. Smooth outer skirt in place. Peel
back tabs at the inner base of the
skirt (2 on front, 2 on back) and
press adhesive to the Tyvek Suit.
Note: Refer to Owners’ Manual
for detailed instructions.
Filters Replacement
A. Remove sealed cap from filters.
3
Turn Blower ON
A
A. Screw female hose connector
of breathing hose to male
connector on blower. Hand tighten.
B. Screw other end of breathing
hose to connector on male
connector on head cover.
Hand tighten.
6
A
Donning Blower Unit
A
A. After Decon, turn filters
counterclockwise. Unscrew filters
and discard.
Before installing new filter check
gasket for any damage.
B
Waist Belt Removal
A
A. Depress switch on top of blower.
A short beep should sound and
light the red LED continuously.
Audible beeping and blinking
red LED light indicates low
battery. Leave contaminated
area and recharge.
www.ilcdover.com
Customer Service: (800) 631-9567
A. Turn on blower and place waist
belt with blower attached around
waist.
B. Snap buckle closed. Adjust waist
belt by pulling belt outward until
snug.
TM
Donning Sentinel XL HP PAPR System
B
A. After removing filters, grasp waist
belt plate and depress both sides
of plate tabs while pulling outward.
B. Remove waist belt.
6000-71270-01 Rev JAN 2011
ECO 112-0124-01