G90 GSM & MMS alarm manual
Quick programming
Installation
1、Insert SIM card, which MMS is activated, without PIN code.
2、Plug in power, +12V, and turn on. It sounds 2 beeps and 1 beep around 20
seconds later to indicate system is ready. If 2 beeps not heard, remove the
power, check, re-insert the SIM, and re-power after 3 minutes.
3、You can ask your operator for correct mms setting
4、Follow the examples to program system
Send sms:“000000M#090012345,090123455 [email protected]” to the SIM
card number in G90.
Key in: “000000 M#0932345678,0935111111,0930333333
[email protected]“
Send this short message to console phone number
Confirmation: administrator will receive a SMS for confirmation as
“M: #0932345678,0935111111,0930333333 [email protected]“to indicate
programming is successful. #0932345678 represents this is the administrator
phone number. ,09351111111 and 0930333333 are general user.
(Note: Administrator does not need password to program and operate the
system; password is necessary for other user(s) to perform the work.
Commands
1. The commands in the table to operate the system
(1)
(3)
(5)
(7)
(9)
N - Program password
E - Program receiver email address
D - Check System Settings
<m><n> -SMS to check images
U –Accessories alarm
(2)
(4)
(6)
(8)
M –Program receiver phone number
A1/A0 –Arm/Disarm
T - Listen-in
C - Default settings
2、Setting examples
N: To Program Password (default password 000000)
Send“000000N111111”SMS to main unit phone number
Confirmation: user will receive a SMS for confirmation as N: 111111
M: To Program Receiver’s Phone Number
Send“000000M#0932345678, 0935111111”SMS to main unit phone number
2
G90 GSM & MMS alarm manual
Confirmation: user will receive a SMS for confirmation as
“M:#0932345678,0935111111” to indicate programming is successful.
Send“000000M” SMS to main unit phone number
Confirmation: user will receive a SMS for confirmation as M-deleted
E: To Program Email Address
Send“[email protected],[email protected]”SMS to main unit phone
number
Confirmation: user will receive a SMS for confirmation as
“E:[email protected],[email protected]” to indicate programming is
successful.
Send“000000E” SMS to main unit phone number, users will receive a SMS for
confirmation as E-deleted
To Activate/Release the System
Send“000000A1” SMS to main unit phone number
Confirmation: user will receive a SMS for confirmation as “detector on” to
indicate programming is successful.
Send“000000A0” SMS to console phone number
Confirmation: user will receive a SMS for confirmation as “detector off”
To check the pictures by sending SMS
Password+m+n
The main unit will send mms to user’s mobile phone and E-mail.
M refers to one of video input.(There are 4 in total and it is from 1 to 4)
N refers to 1-7 pictures.
Ex.: Sending 00000011 to the SIM card number in the system. User’s will
receive 1 picture taken by video 1.It will display the information in the mms.
D: To Check System Settings
Send“000000D” SMS to main unit phone number
Confirmation: user will receive a SMS for confirmation of what you have
programmed.
T: To listen in (need to connect one Mic.)
Send“000000T+phone number” SMS to main unit phone number
In 1 minute, system will call the phone number and the users can listen in the
premise.
If you just send 000000T, the system will call the phone which sends the sms.
3
G90 GSM & MMS alarm manual
Ⅰ、Products introduction
1、1 Introduction
This system is a brand new Hi-Tech product in the wireless communication
era, it has integrated mobile transmission technology and IR image monitoring
and thermo detection such kinds of security technologies.
It has breaking thru the limitation of conventional CCTV system that
transmitting by hardwire cable/modem which is difficult to install and has
higher cost and limited by the installation environment, it also has problem of
easy to be invaded.
This product combines the future mobile user’s needs to let any mobile phone
user (must have GPRS/MMS/SMS function) can use their mobile phone and
mailbox function to back up the image information (to avoid the destroy of
evidences), can real-time receives the alarm messages from any remote
location by the devices or monitoring the real-time voice and image from the
site for immediate identification. It meets various demands from sectors of
household, office, factory, stores….etc.
1、2 Features

IR & camera detecting, the double detection technology can eliminate
the false alarm caused by environmental reasons.

Can connect one to four cameras

Send pictures to your mobile phone or E-mail when it alarms.

Use mobile phone or computer to check the picture anytime wherever.

With IR night vision camera, it provides full time 24 hours day and
night monitoring function.

Remote listen in function

Send pictures and auto-dial to inform the users when it alarms.

Remote control the system, easy to operate
4
G90 GSM & MMS alarm manual
1、3 Products pictures
1、Remote control antenna
6、Power indicate light
2、GSM antenna
7、Power input
3、COM1 port
8、GSM Network indicate light
4、4 video input connection
9、COM2 port
5、SIM socket
1、4 Package List
Standard packing:
(1) One Main unit
(2) Two Antennas
(3) One adaptor
(4) Two remote controls
(5) One user manual
Optional:
(1) 1-4 box cameras
(2) PIR
(3) Other sensors/detectors
(4) Remote control (At most can match 10 pcs)
Please check all components in the package.
5
G90 GSM & MMS alarm manual
1 、5 Major Technical Parameters
PIC Format
JPEG
Resolution
320×240
Remote Effective Range < 100 m
Working Temperature
0-50℃
Relative Humidity
10-90%,non-condense
2、Operation
2、1 Major Function
2、1、1 Active reviewing function
( 1) By Calling
Make sure the feature of MMS is activated for both caller and the main unit.
You just call the unit phone number, and it will hang up the call. After taking a
picture of the premise, it will send the picture to the caller and the first email
address if any email address has been programmed.
Note: You can only check the main unit by calling. If you want to check other
cameras, you need to send sms to check it. If the user already sends sms to
check different cameras, the default checking route by sms will be changed.
Ex.: The you sent sms 00000021 to the main unit, you will see one picture
from video-2.
(2) By Sending SMS
SMS content: Password+Video1+picture quantity
EX.: sending 00000012 to the main unit SIM card number
000000 is the factory default password,1 stands for Video 1.
2 stands for sending 2 pictures to the user’s mobile phone and mail box.
Note:
If none phone number is programmed as alert receiver, any mobile phone with
feature of MMS activated can perform this function.
Only the administrator and user(s) can do so when receiver phone numbers
are programmed, while SMS plus password for other user(s).
2、1、2 Infrared Heat & Motion Detection
Infrared heat & motion is active under system arming mode to detect any motion
object in the premise. If any motion object, i.e. intruder, is detected, system
will send 3 pictures to designated receiver (The first mms is 1 picture, and two
6
G90 GSM & MMS alarm manual
in the second mms). After sending pictures, system calls receiver and it will
call for 5 times if nobody answers the phone. It will alarm again in 10 minutes
when it detects the intruders.
2、1、3Listen in(Need to connect a Mic.)
You just need to send the SMS to the console, and you will receive call back
for the receiver to listen in the sound of premise. You can send SMS: “T+
telephone number or mobile phone number,” in one minute console will phone
the number behind of the “T”. Users answer it and they can monitor the voice
of the scene. Send SMS: “T”, console will call the mobile phone number which
sends SMS.
2、2 Remote control guide
2、2、1 Button instruction
1.Arm
2.Disarm
3.Test
Button 1: Arm
You should operate the remote control unit within 100 meters, transmission
range, to activation the system. Once the button pressed, the console will
sound continuous two beeps, and system enter armed mode after 1 minute.
Button 2: Disarm
You should operate the remote control unit within 100 meters, transmission
range, to release the system. Once the button pressed, the console will sound
a long beep, and system enter disarmed mode.
Button 3: Testing
You should operate the remote control unit within 100 meters, transmission
range, to release the system. Once the button pressed, the console will sound
7
G90 GSM & MMS alarm manual
beep a twice, and system enter disarmed mode. If press and hold the button
for 3 seconds, system will enter or exit factory testing mode.
In testing mode, the system will beep one time when receive the sms, and will
beep twice when send the mms.
2、2、2 Enrollment
If you are not able to operate the remote control unit(s) normally after
System resetting or adding new one(s), you need to re-enroll the remote
control unit (s) to system. Instruction is shown as follows.
(1) Connect the input Power to the system.
(2) After two beeps, press any button within 15 seconds. You will hear one
beep to indicate that it is successful. It can match 10 controls at most.
(3) If the remote control lost or you want to one of them to be disabled. You
can reset the controllers. Sending sms password+C to the system and
follow the ways of (2).
(4) Note: We suggest that the users disarm the system when the system is off.
Because if it is armed, the system will detect the users and alarm
immediately when power on the alarm.
2、3 Extension units operations
You can install 9 extension units within 100 meters of the main unit. The
extension units can be wireless smoke detectors and wireless door/window
sensor. It will send sms to the user when it alarms.
The users should match the extension units to the main unit first.
After power on the main unit and heard two beeps, power on the wireless
detectors and trigger it within 15 seconds. A beep from the main unit indicates
that it matches successfully.
3、Important notice
3、1 SMS setting
(1) Administrator does not need password to program and operate the system,
while password is necessary for other user(s) to perform.
(2) When the SMS content edited in English, it is within 140 bytes. In Chinese,
within 70 words (including figure, letter and other signs), or it will make
8
G90 GSM & MMS alarm manual
settings false.
(3) It doesn’t matter whether the letter in the SMS command is capital or not.
(4) Password is 6 digits from 0-9.
(5) Receivers for phone are 6 and 3 for E-mail at most.
(6) When program several phone numbers and E-mail at the same time, there
must be a space or, or * between them. (Make sure that all these be input in
English)
(7) User can set several functions at the same time and also can set the
system one by one.
(8) The E-mail address must be English letters, digits or underline. With an
interval sign can program others after the mail address. The users can set at
most 3 mail box. The new mailbox will replace the former mail programmed
before. If you program more than one mailbox, programming them at the
same time.
3、2 MMS Access Method
( 1) Follow the below stated sms format in order to make the system work in
different countries.
( 2) Short message form: Password g Homepage(PORT),IP address,APN,( IP
Port),(User Name),(Password),
Be careful that: Content in bracket is default number, ,it is ignorable if not
have.
The ‘,’can not be ignored.
eg: The Establish content of short message for New World of HONG KANG:
000000ghttp://mmsc.nwmobility.com:8002/,192.168.111.1,mms,9201,,,
The short massage content reference to parameters provided by
telecommunic- ation company.
The parameters maybe different in different country and different area,it
depend on the telecommunication company corresponding to the SIM card in
it.
New World
Operator
New World
Access Point (APN) mms
Homepage
http://mmsc.nwmobility.com:8002
IP address
192.168.111.1
Login name
\
Password
\
IP Port
9201
9
G90 GSM & MMS alarm manual
(3) Explain of the short message:
1: “000000” is the default password of host monitor;
2: “g” is command character
3: “http://mmsc.nwmobility.com:8002/” is the Homepage, some times call the
MMSC URL “8002” as the http port, when the port is “80”, it can be ignored.
4: “192.168.111.1” is IP address, Gateway IP address.
5: “mms” is APN, APN is abbreviate of Access point name
6: If the port is “9201”,it can be ignored, but the’,’ followed can not be ignored.
So the short massage above can also be written as:
000000ghttp://mmsc.nwmobility.com:8002/,192.168.111.1,mms,,,,
7: User Name and Password can be ignored if not have, but the’, ’followed
cannot be ignored.
4、Port
4、1 Port
Power: 12V power supply Center positive
GSM Antenna
Antenna: Remote antenna
SIM Card: SIM socket
10
G90 GSM & MMS alarm manual
ISP: Program updating port
Vide o1-Video 04
LED1: Power LED indicate light
LED2: GSM network Light
COM1 definition:
1, 2:Mic. Input connection
3, 4: Flash light driver connection,2 positive,3 negative( Alarm light
connection)
5, 6: Siren connection, 5 positive,6 negative
7, 8: Backup battery connection,7 positive,8 negative
COM2 definition:
1:12V power
2: Negative
CH1
3: PIR input
4: PIR input
5:12V Power
6: Negative
CH2
7: PIR input
8: PIR input
9:12V Power
10: Negative
11: PIR input
12: PIR input
13:12V Power
14: Negative
15: PIR input
16: PIR input
CH3
CH4
4、2 Port parameter
4.2.1 Main parameter
Power: 12V/DC, 1A
Backup battery: 12V, 3.5A plumbic acid battery
Standby current: 40mA (without including extension units)
Max work current: 0.35A (By average, without including flash and siren)
Video signal requirements:
Input CVBS (complex video signals, support PAL, NTSC)
IR requirements: 12V DC Output form: dry contact, N.C
Smoke detector: Voltage: 12V/ DC
Output form: Dry contact ,N.C
Flash light: Voltage: 12V/DC
11
G90 GSM & MMS alarm manual
Siren:
Voltage: 12V/DC
12