Download AIR-CONDITIONER - Heronhill Air Conditioning Ltd
Transcript
Heronhill - for all your Toshiba requirements TOSHIBA FILE NO. A90-9503 SERVICE MANUAL AIR-CONDITIONER SPLIT BUILT-IN DUCT TYPE, HEAT PUMP RAV-162BH-PE/162AH-PE RAV-262BH-PE/262AH-PE RAV-262BH-PE/262AH8-PE RAV-362BH-PE/362AH8-PE RAV-462BH-PE/462AH8-PE SPLIT CEILING TYPE, HEAT PUMP RAV-162CH-PE/RAV-162AH-PE RAV-262CH-PE/RAV-262AH-PE RAV-262CH-PE/RAV-262AH8-PE RAV-362CH-PE/RAV-362AH8-PE RAV-462CH-PE/RAV-462AH8-PE SPLIT WALL TYPE, HEAT PUMP RAV-162KH(W)-PE/RAV-162AH-PE RAV-262KH(W)-PE/RAV-262AH-PE RAV-262KH(W)-PE/RAV-262AH8-PE SPLIT CASSETTE TYPE, HEAT PUMP RAV-132UH-PE RAV-162UH-PE/162AH-PE RAV-262UH-PE/262AH-PE RAV-262UH-PE/262AH8-PE RAV-362UH-PE/362AH8-PE RAV-462UH-PE/462AH-PE Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements CONTENTS 1. SPECIFICATIONS ............................................................................................................................................................... 3 2. CONSTRUCTION VIEWS ................................................................................................................................................ 15 3. WIRING DIAGRAM ........................................................................................................................................................... 22 4. SPECIFICATIONS OF ELECTRICAL PARTS ................................................................................................................. 32 5. REFRIGERANT PIPING DIAGRAM ................................................................................................................................ 41 6. REMOTE CONTROLLER ................................................................................................................................................. 46 7. OUTLINE OF CONTROL CIRCUIT ................................................................................................................................. 59 8. DESCRIPTION OF INDOOR UNIT CONTROL CIRCUIT ............................................................................................. 62 9. DESCRIPTION OF OUTDOOR UNIT CONTROL CIRCUIT ......................................................................................... 68 10. OPERATION OF AIR CONDITIONER FROM OUTDOOR UNIT .................................................................................. 73 11. EMERGENCY OPERATION ............................................................................................................................................. 74 12. APPLIED CIRCUIT ............................................................................................................................................................ 75 13. WIRING FOR GROUP OPERATION .............................................................................................................................. 75 14. PERFORMANCE CHARACTER ...................................................................................................................................... 76 15. EXPLODED VIEWS AND PARTS LISTS ........................................................................................................................ 79 SUMMARY • The units referred to within this manual conform with the protection requirements of Directives 89/336/EEC Electromagnetic Compatibility and 73/23/EEC Low Voltage. • Operating conditions of units are as follows: TEMPERATURE OUTDOOR TEMPERATURE -2 TO 43°C (COOL) -10 TO 21°C (HEAT) ROOM TEMPERATURE 18 TO 32°C (COOL) 15 TO 29°C (HEAT) ROOM HUMIDITY LESS THAN 80% (COOL) Note 1 : Cooling Capacity is based on the following temperature conditions: Indoor air inlet temperature 27°C DB, 19°C WB. Outdoor air inlet temperature 35°C DB. Note 2: Heating Capacity is based on the following temperature conditions: Indoor air inlet temperature 20°C DB. Outdoor air inlet temperature 7°C DB, 6°C WB. -2- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 1. SPECIFICATIONS MODEL ITEM Cooling capacity kW RAV-162BH-PE 4.5 Heating capacity kW 5.0 1 Phase 220-240 50 Power source V Hz COOLING HEATING Power consumption kW 2.3 2.2 Power factor % 90 90 Running current A 11.1 10.6 Starting current Operating noise (SPL) Refrigerant 60 A 42/39/36 50 I n d o o r u n i t (High, Med, Low) d B ( A ) Outdoor unit dB(A) Name of refrigerant R-22 Charge volume kg Add. volume (20-30m) g/m Larger side size mm 1.6 35 Capillary tube & Expansion valve Refrigerant control Ø12.7 Coupler style Flare Smaller side size Coupler style Standard length Interconnection pipe Maximum length (of one way) *1 6.4 mm Ø m Flare 7.5 30 m Maximum height Indoor unit height m 15 Outdoor unit height m 30 Condensate drain pipe diameter INDOOR UNIT Model Ø 32 (OD) RAV-162BH-PE mm Appearance colour Dimensions Black (Zinc galvanized steel + thermal insulator) Height mm 345 Width mm 700 Depth mm 800 Net weight kg 39 Heat exchanger type Indoor fan type Finned tube Multi-blade fan Air volume m 3/h Fan motor output W External static pressure 840 60 Standard mmAq 4 Max. motor mmAq 10 OUTDOOR UNIT Model Appearance colour Dimensions RAV-162AH-PE Bronze white (Munsell 6Y7.5/1) Height mm 740 Width mm 880 Depth mm 310 kg 61 Finned tube Net weight Heat exchanger type Propeller fan Outdoor fan type Air flow volume m 3/h Fan motor output W 2,700 39 Model Compressor Output PH250X3-4LS kW Protective device 2.0 High pressure switch, Fuse, Crankcase heater, Overload relay, Bimetal thermostat CEILING PANEL Model RBC-B161PE(W) Appearance colour Dimensions Height mm Silky mist (Munsell 1Y8.9/0.5) 40 Width mm 780 Depth mm 500 4 Net weight kg Air filter Washable Flexible duct RBC-FD202E Blowout unit RBC-BU1E(W) Suction canvas RBC-CA161BE Long-life filter kit RBC-LK161BE RBC-DK161BE-P Built-in duct filter kit Specifications are subject to change without notice. * Note 1: These mean actual length. -3- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements ITEM MODEL Cooling capacity kW Heating capacity kW RAV-262BH-PE 7.9 Phase Power source RAV-262BH-PE 7.1 V Hz 1 3 220-240 380-415 50 COOLING HEATING Power consumption kW 3.0 2.75 2.8 2.7 Power factor % 88 87 86 85 Running current A 14.8 13.8 4.7 4.6 Starting current Operating noise (SPL) Refrigerant COOLING HEATING A 80 25 43/40/37 I n d o o r u n i t (High, Med, Low) d B ( A ) Outdoor unit dB (A) Name of refrigerant Charge volume kg Add. volume (20-30m) g/m 53 R-22 2.35 60 Refrigerant control Capillary tube & Expansion valve Larger side size mm ø 15.9 Smaller side size mm ø 9.5 Coupler style Standard length m Flare 7.5 m 30 m 15 Coupler style Interconnection pipe Maximum length (of one way) Flare *1 Maximum height Indoor unit height Outdoor unit height Condensate drain pipe diameter m 30 ø 32 (OD) mm INDOOR UNIT Model RAV-262BH-PE Appearance colour Dimensions Black (zinc galvanized steel + thermal insulator) Height mm 345 Width mm 1,000 Depth mm 800 kg 53 Finned tube Multi-blade fan Net weight Heat exchanger type Indoor fan type Air volume m 3/h Fan motor output W 100 mmAq mmAq 10 External static pressure Standard Max. motor 1,140 4 OUTDOOR UNIT Model Appearance colour Dimensions RAV-262AH-PE Height mm 790 Width mm 880 Depth mm 310 kg 80 Finned tube Propeller fan Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h Fan motor output W Compressor 3,000 63 Model Output PH330X3-4MS kW YH330X3-MS 2.2 2.2 High pressure switch, Fuse, Bimetal thermostat, Crankcase heater, Inner overload relay Safety device CEILING PANEL Model Appearance colour Dimensions RAV-262AH8-PE Bronze white (Munsell 6Y7.5/1) Height Width mm mm Depth mm kg Net weight High pressure switch, Fuse, Overcurrent relay, Crankcase heater, Thermostat, Return-Lock RBC-B260PE(W) Silky mist (Munsell 1Y8.9/0.5) 40 1,080 500 6 Washable Air filter Flexible duct RBC-FD202E Blowout unit RBC-BU1E(W) Suction canvas RBC-CA260BE Long-life filter kit RBC-LK260BE RBC-DK261BE-P Built-in duct filter kit Specifications are subject to change without notice. * Note 1: These mean actual length. -4- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL ITEM RAV-362BH-PE RAV-462BH-PE Cooling capacity kW 10.0 12.5 Heating capacity kW 10.8 13.8 3 Phase Power source V Hz 3 380-415 380-415 50 50 COOLING 4.2 HEATING COOLING HEATING 3.6 5.15 4.9 Power consumption kW Power factor % 89 87 87 88 Running current A 6.8 6.0 8.5 8.0 Starting current Operating noise (SPL) Refrigerant A I n d o o r u n i t (High, Med, Low) d B ( A ) Outdoor unit dB (A) Name of refrigerant 50 46/43/40 55 55 R-22 R-22 3.9 Charge volume kg 3.4 Add. volume (20-50m) g/m 50 50 Capillary tube & Expansion valve Capillary tube & Expansion valve mm ø 19 (ø22) ø 19 (ø22) Smaller side size mm Flare ø 9.5 Flare ø 9.5 Coupler style Standard length m Flare 7.5 Flare 7.5 m 50 50 Indoor unit height m 20 20 Outdoor unit height m 50 50 ø 32 (OD) ø 32 (OD) RAV-362BH-PE RAV-462BH-PE Refrigerant control Larger side size *2 Coupler style Interconnection pipe 42 45/42/39 Maximum length (of one way) *1 Maximum height Condensate drain pipe diameter mm INDOOR UNIT Model Appearance colour Dimensions Black (zinc galvanized steel + thermal insulator) Height mm 345 345 Width mm 1,350 1,350 Depth 800 mm 800 Net weight kg 58 62 Heat exchanger type Indoor fan type mm Finned tube Finned tube Air volume m 3/h Multi-blade fan 1,820 Multi-blade fan 2,100 120 4 140 4 10 RAV-362AH8-PE 10 RAV-462AH8-PE W Fan motor output External static pressure OUTDOOR UNIT Model Standard Max. motor mmAq Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) Height mm 1,240 1,240 Width mm 930 930 Depth mm 385 385 kg 107 115 Finned tube Propeller fan Finned tube Propeller fan mmAq Appearance colour Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h 6,000 6,000 Fan motor output W 39+63 39+63 YH406JA YH506JA Compressor Model Output kW 3.0 Safety device CEILING PANEL Model High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay RBC-B460PE(W) Appearance colour Dimensions 3.75 High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay RBC-B460PE(W) Silky mist (Munsell 1Y8.9/0.5) Height mm Silky mist (Munsell 1Y8.9/0.5) 40 Width mm 1,430 1,430 Depth mm 500 7 500 Washable Washable Net weight kg Air filter 40 7 Flexible duct RBC-FD202E Blowout unit RBC-BÚ1E(W) Suction canvas RBC-CA460BE Long-life filter kit RBC-LK460BE Built-in duct filter kit RBC-DK461BE-P Specifications are subject to change without notice. * Note 1: These mean actual length. * Note 2: (ø22) should be used when length of pipe exceeds 30m. -5- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL ITEM RAV-162CH-PE Cooling capacity kW 4.5 Heating capacity kW 5.0 Phase 1 220-240 V Power source 50 Hz COOLING HEATING 2.2 Power consumption kW 2.3 Power factor % 90 90 Running current A 11.1 10.6 Starting current Operating noise (SPL) 60 A Indoor unit (High, Med, Low) Outdoor unit 42/39/36 dB(A) dB(A) 50 Name of refrigerant Refrigerant R-22 Charge volume kg Add. volume (20-30m) g/m Larger side size mm 1.6 35 Refrigerant control Capillary tube & Expansion valve Ø 12.7 Coupler style Flare Smaller side size Coupler style Standard length Interconnection pipe Maximum length (of one way) *1 6.4 mm Ø m Flare 7.5 30 m Maximum height Indoor unit height m 15 Outdoor unit height m 30 Condensate drain pipe diameter mm Ø INDOOR UNIT Model Appearance colour Dimensions 20 (ID) RAV-162CH-PE Silky mist Height mm 188 Width mm 1,030 Depth mm 640 Net weight kg 24 Finned tube Multi-blade fan Heat exchanger type Indoor fan type m 3/h Air volume Fan motor output 780 W 34 Air filter Washable OUTDOOR UNIT Model Appearance colour Dimensions RAV-162AH-PE Height mm Bronze white (Munsell 6Y7.5/1) 740 Width mm 880 Depth mm 310 kg Net weight 61 Heat exchanger type Outdoor fan type Finned tube Propeller fan Air flow volume m 3/h Fan motor output W 2,700 39 Model Compressor Output Protective device PH250X3-4LS kW 2.0 High pressure switch, Fuse, Crankcase heater, Overload relay, Bimetal thermostat Specifications are subject to change without notice. * Note 1 : These mean actual length. -6- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements ITEM MODEL Cooling capacity Heating capacity RAV-262CH-PE RAV-262CH-PE kW 7.1 kW 7.9 Phase Power source V Hz 1 3 220-240 380-415 50 COOLING HEATING Power consumption kW 3.0 2.75 2.8 2.7 Power factor % 88 87 86 85 Running current A 14.8 13.8 4.7 4.6 HEATING A Starting current Operating noise (SPL) COOLING Indoor unit Outdoor unit 80 53 dB (A) Name of refrigerant Refrigerant Charge volume kg Add. volume (20-30m) g/m R-22 2.35 60 Refrigerant control Capillary tube & Expansion valve Larger side size mm ø 15.9 Smaller side size mm ø 9.5 Coupler style Standard length m Flare 7.5 m 30 Coupler style Interconnection pipe Maximum length (of one way) Flare *1 Outdoor unit height Condensate drain pipe diameter INDOOR UNIT Model Maximum height Appearance colour Indoor unit height Dimensions m 15 m 30 mm ø 20 (ID) RAV-262CH-PE Silky mist Height mm 188 Width mm 1,230 Depth mm 640 kg 28 Finned tube Multi-blade fan Net weight Heat exchanger type Indoor fan type Air volume m 3/h Fan motor output Air filter W 1,200 34 Washable OUTDOOR UNIT Model RAV-262AH-PE Appearance colour Dimensions RAV-262AH8-PE Bronze white (Munsell 6Y7.5/1) Height mm 790 Width mm 880 Depth mm 310 kg 80 Finned tube Propeller fan Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h Fan motor output W Compressor 25 45/41/37 dB (A) 3,000 63 Model Output PH330X3-4MS kW 2.2 High pressure switch, Fuse, Bimetal thermostat, Crankcase heater, Inner overload relay Safety device YH330X3-MS 2.2 High pressure switch, Fuse, Overcurrent relay, Crankcase heater, Thermostat, Return-Lock Specifications are subject to change without notice. * Note 1 : These mean actual length. -7- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL ITEM RAV-362CH-PE RAV-462CH-PE Cooling capacity kW 10.5 13.0 Heating capacity kW 10.8 13.8 Phase Power source V Hz 3 3 380-415 380-415 50 50 HEATING COOLING HEATING Power consumption kW 4.2 3.6 5.15 4.9 Power factor % 89 87 87 88 Running current A 6.8 6.0 8.5 8.0 Starting current Operating noise (SPL) COOLING A Indoor unit (High, Med, Low) Outdoor unit dB (A) dB (A) Name of refrigerant Refrigerant 50 49/45/41 55 55 R-22 R-22 3.9 Charge volume kg 3.4 Add. volume (20-50m) g/m 50 50 Capillary tube & Expansion valve Capillary tube & Expansion valve mm ø 19 (ø22) ø 19 (ø22) Smaller side size mm Flare ø 9.5 Flare ø 9.5 Coupler style Standard length m Flare 7.5 Flare 7.5 m 50 50 Indoor unit height m 20 20 Outdoor unit height m 50 50 ø 20 (ID) ø 20 (ID) RAV-362CH-PE RAV-462CH-PE Silky mist Silky mist Refrigerant control Larger side size *2 Coupler style Interconnection pipe 42 47/43/40 Maximum length (of one way) *1 Maximum height Condensate drain pipe diameter mm INDOOR UNIT Model Appearance colour Dimensions Height mm 240 240 Width mm 1,430 1,630 Depth 640 mm 640 Net weight kg 39 44 Heat exchanger type Indoor fan type mm Finned tube Finned tube Air volume m 3/h Multi-blade fan 1,680 Multi-blade fan 2,100 Fan motor output Air filter W 75 Washable 75 Washable OUTDOOR UNIT Model Appearance colour Dimensions RAV-362AH8-PE RAV-462AH8-PE Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) Height mm 1,240 1,240 Width mm 930 930 Depth mm 385 385 kg 107 115 Finned tube Propeller fan Finned tube Propeller fan Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h 6,000 6,000 Fan motor output W 39+63 39+63 YH406JA YH506JA Compressor Model Output kW 3.0 High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay Safety device 3.75 High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay Specifications are subject to change without notice. * Note 1 : These mean actual length. * Note 2 : (ø22) should be used when the length of pipe exceeds 30m. -8- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL RAV-162KH(W)-PE ITEM Cooling capacity kW 4.5 Heating capacity kW 5.0 Phase Power source 1 V 220-240 50 Hz COOLING HEATING Power consumption kW 2.3 2.2 Power factor % 90 90 Running current A 11.1 10.6 Starting current Operating noise (SPL) 60 A Indoor unit (High, Med, Low) Outdoor unit dB(A) dB(A) 45/40/38 50 Name of refrigerant Refrigerant R-22 Charge volume kg Add. volume (20-30m) g/m Larger side size mm 1.6 35 Refrigerant control Capillary tube & Expansion valve Ø 12.7 Coupler style Flare Smaller side size Coupler style Standard length Interconnection pipe Maximum length (of one way) *1 mm Ø m Flare 7.5 6.4 30 m Maximum height Indoor unit height m 15 Outdoor unit height m 30 Condensate drain pipe diameter INDOOR UNIT Model mm Ø 20 (ID) RAV-162KH(W)-PE Appearance colour Dimensions Silky mist Height mm 370 Width mm 1,020 Depth mm 200 Net weight kg 19 Heat exchanger type Finned tube Transverse flow fan Indoor fan type Air volume m 3/h Fan motor output W 780 27 Air filter Washable OUTDOOR UNIT Model Appearance colour Dimensions RAV-162AH-PE Bronze white (Munsell 6Y7.5/1) Height mm 740 Width mm 880 Depth mm 310 Net weight kg 61 Heat exchanger type Outdoor fan type Finned tube Propeller fan Air flow volume m 3/h Fan motor output W 2,700 39 Model Compressor Output Protective device PH250X3-4LS kW 2.0 High pressure switch, Fuse, Crankcase heater, Overload relay, Bimetal thermostat Specifications are subject to change without notice. * Note 1 : These mean actual length. -9- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements ITEM MODEL Cooling capacity kW Heating capacity kW RAV-262KH(W)-PE 7.9 Phase Power source RAV-262KH(W)-PE 7.1 V 1 3 220-240 380-415 50 Hz COOLING HEATING Power consumption kW 3.0 2.75 2.8 2.7 Power factor % 88 87 86 85 Running current A 14.8 13.8 4.7 4.6 Starting current HEATING A Indoor unit Outdoor unit Operating noise (SPL) COOLING 80 53 Name of refrigerant Refrigerant Charge volume kg Add. volume (20-30m) g/m 25 46/42/38 dB (A) dB (A) R-22 2.35 60 Refrigerant control Capillary tube & Expansion valve Larger side size mm ø 15.9 Smaller side size mm ø 9.5 Coupler style Standard length m Flare 7.5 m 30 Coupler style Interconnection pipe Maximum length (of one way) Flare *1 Outdoor unit height Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Dimensions m 15 m 30 ø 20 (ID) mm RAV-262KH(W)-PE Maximum height Indoor unit height Silky mist Height mm 370 Width mm 1,350 Depth mm 200 kg 25 Finned tube Transverse flow fan Net weight Heat exchanger type Indoor fan type Air volume m 3/h Fan motor output Air filter W 1,200 27 Washable RAV-262AH-PE OUTDOOR UNIT Model Appearance colour Dimensions Height mm 790 Width mm 880 Depth mm 310 kg 80 Finned tube Propeller fan Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h Fan motor output W Compressor RAV-262AH8-PE Bronze white (Munsell 6Y7.5/1) 3,000 63 Model Output kW PH330X3-4MS YH330X3-MS 2.2 2.2 High pressure switch, Fuse, Bimetal thermostat, Crankcase heater, Inner overload relay Safety device High pressure switch, Fuse, Overcurrent relay, Crankcase heater, Thermostat, Return-Lock Specifications are subject to change without notice. * Note 1 : These mean actual length. -10- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL RAV-132UH-PE ITEM 1 Power source Phase V Power consumption Hz kW 0.066 Power factor % 93 Running current Starting current A 0.31 A 0.6 Operating noise (SPL) (High, Med, Low) 220-240 50 41/38/35 dB(A) R-22 Refrigerant Name of refrigerant mm Larger side size Ø12.7 Interconnection pipe Coupler style Flare Smaller side size Ø6.4 mm Flare Coupler style Condensate drain pipe diameter Ø32(OD) mm Black (zinc galvanized steel + Thermal insulator) Appearance colour Dimensions Height mm 300 Width mm 840 Depth mm 740 28 kg Net weight Finned tube Heat exchanger type Radial fan Indoor fan type 3 Air volume m /h 630 Fan motor output W 25 RBC-U262PG(W)-PE CEILING PANEL Model Silky mist (Munsell 1Y8.9/0.5) Appearance colour Dimensions Height mm 28 Width mm 1000 Depth mm 840 Net weight kg 7 Washable Air filter Specifications are subject to change without notice. -11- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL RAV-162UH-PE ITEM Cooling capacity kW 4.5 Heating capacity kW 5.0 Power source Phase V 1 220-240 50 Hz COOLING HEATING Power consumption kW 2.3 2.2 Power factor % 90 90 Running current A 11.1 10.6 Starting current Operating noise (SPL) 60 A Indoor unit (High, Med, Low) Outdoor unit dB(A) dB(A) 44/40/37 50 Name of refrigerant Refrigerant R-22 Charge volume kg Add. volume (20-30m) g/m Larger side size mm 1.6 35 Refrigerant control Capillary tube & Expansion valve Ø 12.7 Coupler style Flare Smaller side size Coupler style Standard length Interconnection pipe Maximum length (of one way) *1 mm Ø m Flare 7.5 6.4 30 m Maximum height Indoor unit height m 15 Outdoor unit height m 30 Condensate drain pipe diameter INDOOR UNIT Model mm Ø 32 (OD) RAV-162UH-PE Appearance colour Dimensions Black (zinc galvanized steel + thermal insulator) Height mm 300 Width mm 840 Depth mm 740 Net weight kg 29 Heat exchanger type Indoor fan type Finned tube Radial fan m 3/h Air volume Fan motor output 980 W 30 Air filter Washable OUTDOOR UNIT Model Appearance colour Dimensions RAV-162AH-PE Bronze white (Munsell 6Y7.5/1) Height mm 740 Width mm 880 Depth mm 310 Net weight kg 61 Finned tube Propeller fan Heat exchanger type Outdoor fan type Air flow volume m 3/h Fan motor output W 2,700 39 Model Compressor Output PH250X3-4LS 2.0 kW Protective device High pressure switch, Fuse, Crankcase heater, Overload relay, Bimetal thermostat CEILING PANEL Model RBC-U262PG(W)-PE Appearance colour Dimensions Silky mist (Munsell 1Y8.9/0.5) Height mm 28 Width mm 1,000 Depth mm 840 kg Net weight 8.5 Washable Air filter Specifications are subject to change without notice. * Note 1 : These mean actual length. -12- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements ITEM MODEL Cooling capacity kW Heating capacity kW Phase RAV-262UH-PE 7.9 V Power source RAV-262UH-PE 7.1 1 3 220-240 380-415 Hz 50 COOLING HEATING Power consumption kW 3.0 2.75 2.8 2.7 Power factor % 88 87 86 85 Running current A 14.8 13.8 4.7 4.6 Starting current Operating noise (SPL) COOLING HEATING A Indoor unit Outdoor unit 80 53 dB (A) Name of refrigerant Refrigerant R-22 Charge volume kg Add. volume (20-30m) g/m 2.35 60 Refrigerant control Interconnection pipe Capillary tube & Expansion valve Larger side size Coupler style mm ø 15.9 Smaller side size mm ø 9.5 Coupler style Standard length m Flare 7.5 m 30 Maximum length (of one way) Flare *1 Outdoor unit height Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Dimensions m 15 m 30 ø 32(OD) mm RAV-262UH-PE Maximum height Indoor unit height Black (zinc galvanized steel + thermal insulator) Height mm 300 Width mm 840 Depth mm 740 kg 29 Finned tube Radial fan Net weight Heat exchanger type Indoor fan type Air volume 1,260 m 3/h Fan motor output Air filter 45 W Washable OUTDOOR UNIT Model RAV-262AH-PE Height mm 790 Width mm 880 Depth mm 310 kg 80 Finned tube Propeller fan Net weight Heat exchanger type Outdoor fan type Air flow volume m 3/h Fan motor output W 3,000 63 Model Compressor Output kW PH330X3-4MS YH330X3-MS 2.2 2.2 High pressure switch, Fuse, Bimetal thermostat, Crankcase heater, Inner overload relay Safety device CEILING PANEL Model High pressure switch, Fuse, Overcurrent relay, Crankcase heater, Thermostat, Return-Lock RBC-U262PG(W)-PE Appearance colour Dimensions RAV-262AH8-PE Bronze white (Munsell 6Y7.5/1) Appearance colour Dimensions 25 45/41/37 dB (A) Silky mist (Munsell 1Y8.9/0.5) Height mm 28 Width mm 1,000 Depth mm 840 kg 8.5 Net weight Air filter Washable Specifications are subject to change without notice. * Note 1 : These mean actual length. -13- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements MODEL ITEM RAV-362UH-PE RAV-462UH-PE Cooling capacity kW 10.0 12.5 Heating capacity kW 10.8 13.8 Phase 3 3 380-415 50 380-415 50 Power source V Hz COOLING HEATING COOLING HEATING Power consumption kW 4.2 3.6 5.15 4.9 Power factor % 89 87 87 88 Running current A 6.8 6.0 8.5 8.0 Starting current Operating noise (SPL) A Indoor unit Outdoor unit dB (A) dB (A) Name of refrigerant Refrigerant 50 52/47/44 55 55 R-22 R-22 3.9 Charge volume kg 3.4 Add. volume (20-50m) g/m 50 50 Capillary tube & Expansion valve Capillary tube & Expansion valve mm ø 19 (ø22) ø 19 (ø22) Smaller side size mm Flare ø 9.5 Flare ø 9.5 Coupler style Standard length m Flare 7.5 Flare 7.5 m 50 50 Indoor unit height m 20 20 Outdoor unit height m 50 50 ø 32 (OD) ø 32 (OD) RAV-362UH-PE RAV-462UH-PE Refrigerant control Larger side size *2 Coupler style Interconnection pipe 42 50/45/42 Maximum length (of one way) *1 Maximum height Condensate drain pipe diameter mm INDOOR UNIT Model Appearance colour Dimensions Black (zinc galvanized steel + thermal insulator) Height mm 350 350 Width mm 1,130 1,130 Depth 740 mm 740 Net weight kg 53 53 Heat exchanger type Indoor fan type mm Finned tube Finned tube Centrifugal fan Centrifugal fan Air volume m 3/h W 1,680 1,860 Fan motor output Air filter OUTDOOR UNIT Model Appearance colour Dimensions Washable RAV-462AH8-PE Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) mm 1,240 1,240 Width mm 930 930 Depth mm 385 385 kg 107 115 Finned tube Finned tube Propeller fan 6,000 Propeller fan 6,000 Heat exchanger type Outdoor fan type m 3/h Air flow volume Fan motor output W Model Output kW 39+63 39+63 YH406JA YH506JA 3.0 High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay Safety device CEILING PANEL Model Appearance colour Dimensions 90 Washable RAV-362AH8-PE Height Net weight Compressor 80 3.75 High pressure switch, Fuse, Overload relay, Crankcase heater, Inner overload relay RBC-U462PG(W)-PE RBC-U462PG(W)-PE Silky mist (Munsell 1Y8.9/0.5) Silky mist (Munsell 1Y8.9/0.5) Height mm 28 28 Width mm 1,290 1,290 Depth mm 840 840 kg 10 10 Washable Washable Net weight Air filter Specifications are subject to change without notice. * Note 1 : These mean actual length. * Note 2: (ø22) should be used when the length of pipe exceeds 30m. -14- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 2. CONSTRUCTION VIEWS 2.1 2.1 2.1 2.1 2.1 Indoor unit RAV-162BH-PE RAV-262BH-PE RAV-362BH-PE RAV-462BH-PE Thermal insulator height 11mm around supply air port Unit dimension: 800 Air oulet Unit dimension: A Hanging bolt pitch: B Hanging bolt pitch: 565 Hanging bolt 6-ø4 Mounting screw hole ø 160 Provided at site Refrigerant pipe connection port (Larger side øF) ø 125 Knockout hole (rear) (Fresh air inlet) Refrigerant pipe connection port (Smaller side øG) Long-life filter kit (Option) Drain pipe connection port (Inner diameter: 32) Ceiling opening: D Panel outer dimension: E Suction canvas Ceiling opening: 470 (Port diameter: 25 nominal, for PVC pipes) Panel outer dimension: 500 (Option) Ceiling panel (Option) Wiring connection port Ensure that there is sufficient space around the indoor units for installation and servicing. [Indoor unit] (Unit: mm) Model A B F RAV-162BH-PE 700 750 12.7 RAV-262BH-PE 10001050 15.9 RAV-362/462BH-P 13501400 19.0 G H J K M 6.4 252 280 280 1 9.5 252 580 290 2 9.5 252 930 310 3 N 2 3 4 Inspection hole Provide an inspection hole around here. -15- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 2.2 Indoor unit Hanging plate (Left) RAV-162CH-PE RAV-262CH-PE RAV-362CH-PE RAV-462CH-PE Hanging bolt Less than 40 Hanging bolt pitch Drain piping joint Hard vinyl chloride pipe inner dia. 20mm Refrigerant piping joint (Liquid øF) Knock - out holes for piping and wiring (Hanging bolt pitch) Refrigerant piping joint (Gas øG) Hanging plate (Right) Outer hanging bolt pitch Minimum Right - side panel knock - out for piping and wiring (Horizontal installation) Air inlet Space required for service and installation Air filter Minimum Location slots 2-(4.5x9) Door Remote controller Greater than 400 Fax: 01823 665807 www.heronhill.co.uk Tel: 01823 665660 Alternative Knock - out hole for drain piping Hanging bolt hole 4 - (12x25) Slot Inner hanging bolt pitch Hanging bolt Less than 40 -16- Greaterthan500 Heronhill - for all your Toshiba requirements 2.3 Indoor Unit RAV-162KH(W)-PE RAV-262KH(W)-PE Refrigerant piping joint (Smaller side ø C) Refrigerant piping joint (Longer Side ø B) (Both sides) Piping hole Air oulet Drain pipe (Knockout hole) (4-way adjustable) Long hole Piping hole (Knockout hole) Model A B C RAV-162KH(W)-P 1020 12.7 6.4 RAV-262KH(W)-P 1350 15.9 9.5 Door Remote controller RAV-162KH(W)-PE Long hole More than 30 Anchor bolt hole 4-10x20 long hole RAV-262KH(W)-PE More than 300 More than 300 Long hole Space required for service Anchor bolt hole 4-10x20 long hole Installation board mounting bolt hole location -17- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Remote controller Long hole More than 15 Ceiling panel 2 Ceiling opening: 940 Panel outer dimension: 1000 Hanging bolt Panel outer dimension: 840 Ceiling opening: 780 Tel: 01823 665660 www.heronhill.co.uk Power supply connection port Drain pipe connection port Water supply check port N View Smaller side B Refrigerant pipe connection port (Larger side A) Refrigerant pipe connection port Heronhill - for all your Toshiba requirements 2.4 Indoor Unit Unit model RAV-132UH-PE RAV-162UH-PE RAV-262UH-PE Panel model RBC-262PG(W)-PE -18- Fax: 01823 665807 Tel: 01823 665660 Ceiling panel Z Ceiling opening: 1230 Panel outer dimension: 1290 www.heronhill.co.uk Remote controller Ceiling opening: 780 Power supply connection port Drain pipe connection port Water supply check port Panel outer dimension: 840 Door Long hole Hanging bolt (Smaller side ø9.5) Refrigerant pipe connection port (Larger side ø19) Refrigerant pipe connection port Z View Heronhill - for all your Toshiba requirements 2.5 Indoor Unit Unit model RAV-362UH-PE RAV-462UH-PE Panel model RBC-U462PG(W)-PE More than 15 -19- Fax: 01823 665807 Heronhill - for all your Toshiba requirements 2.6 Outdoor unit RAV-162AH-PE RAV-262AH-PE RAV-262AH8-PE Knock - out hole for drain (2-20 x 60 long hole) Hole for drain (2-ø19 hole) Refrigerant piping joint (larger side D) Refrigerant piping joint (Smaller side C) Earth screw Anchor bolt hole (4-12 x 18 long hole) Air outlet Carrying handle Electric parts box (M6) Terminal cover B A (Both sides) Blow out guide mounting hole (4-ø3 embossing) Space required for service (Space for wiring and piping) Outlet Outlet (Space for wiring and piping) When installed with the inlet faced to the wall side When installed with the outlet faced to the wall side (Unit: mm) Model A B C D RAV-162AH-PE 740 380 ø6.4 ø12.7 RAV-262AH-PE RAV-262AH8-PE 790 430 ø9.5 ø15.9 -20- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 2.7 Outdoor Unit RAV-362AH8-PE RAV-462AH8-PE Knock-out hole (Bottom) (2-30 x 80 long hole for drain disposal) Air inlet Refrigerant piping joint (Larger side ø 19) Refrigerant piping joint connection port (Smaller side ø 9.5) Air inlet Earth screw Air outlet (M6) Carrying handle (Both sides) Carrying handle (Front side only) Terminal cover Anchor bolt hole Air outlet (4 - 12 x 18 long hole) Blow out guide mounting hole (8 - ø3 embossing) Blow out guide mounting hole (8-ø3 embossing) Knock-out hole (ø 40) Space required for service (Space for wiring and piping) Outlet Outlet (Space for wiring and piping) When installed with the inlet faced to the wall side When installed with the outlet faced to the wall side -21- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 www.heronhill.co.uk F2 (3 Phase model) Power Supply 220/240V 50Hz Earth Screw F2 (1 Phase model) -22- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Power Supply 380/415V 3N 50Hz Earth Screw Outdoor unit Fan Motor Running Capacitor Transformer Fuse (PCB) RC TR F Name FM Symbol F K 14 TA TC Sensor Sensor K 1~14 Relay Symbol CN11 (FLOAT) CN03 (SERIAL) (N) (L1) CN10 (PUMP) UL K4 WHI RC L K3 M H K2 REMOCON K1 ( output ) Name CN01 (TRANS) YEL K1 BLU ORN Indoor unit CN12 BLK RED GRN/YEL GRY FM CN05 (TC) CN04 (TA) CN07 (FAN) YEL BLU ORN BLK BRW RED TR TC TA YEL BLU ORN BLK RED Tel: 01823 665660 (Fan speed increase option) FM YEL BLU ORN BLK BRW RED Remote Controller Connector assembly (accessory) Heronhill - for all your Toshiba requirements 3.1 RAV-162BH-PE/RAV-262BH-PE RAV-362BH-PE/RAV-462BH-PE 3. WIRING DIAGRAM Tel: 01823 665660 www.heronhill.co.uk F2 Power Supply 220/240V 50Hz Earth Screw F2 (1 Phase model) -23- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Power Supply 380/415V 3N 50Hz Earth Screw (3 Phase model) Outdoor unit Indoor unit Remote Controller Fan Motor Running Capacitor Transformer Fuse (PCB) RC TR F Name FM Symbol Name Geared Motor Sensor Sensor K1~K14 Relay GM TC TA Symbol K 11 K 14 K1 CN09(LOUVER) CN11 (FLOAT) CN03 (SERIAL) (N) (LI) F TR GM CN01 (TRANS) RC WHI K1 ( output ) L K3 K2 M H FM GRY GRN/YEL RED CN05 (TC) CN04 (TA) CN07 (FAN) YEL B L U ORN BLK UL K4 REMOCON CN12 TC TA Heronhill - for all your Toshiba requirements 3.2 RAV-162CH-PE/RAV-262CH-PE RAV-362CH-PE/RAV-462CH-PE www.heronhill.co.uk F2 (3 Phase model) Power Supply 220/240V 50Hz Earth Screw F2 (1 Phase model) -24- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Power Supply 380/415V 3N 50Hz Earth Screw Outdoor unit Indoor unit Fan Motor Running Capacitor Transformer Fuse (PCB) RC TR F Name FM Symbol Sensor Sensor K1~K14 Relay TC TA Symbol K 14 Name CN11 (FLOAT) CN03 (SERIAL) (N) (L1) F CN10 (PUMP) K1 K1 ( output ) CN01 (TRANS) WHI RC K4 UL L K3 M H TC K2 REMOCON CN12 RED TR WHI BLU ORN BLK Tel: 01823 665660 CN07 (FAN) CN05 (TC) CN04 (TA) FM G R N / Y E L YEL Remote Controller TC TA Heronhill - for all your Toshiba requirements 3.3 RAV-162KH(W)-PE RAV-262KH(W)-PE RED www.heronhill.co.uk Power Supply 220/240V 50Hz Earth Screw F2 (1 Phase model) -25- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Outdoor unit Indoor unit Fan Motor Running Capacitor Transformer Sensor Sensor Fuse (PCB) RC TR TA TC F Name DM FM Symbol Spark Killer 43 43 Symbol Relay CN11 (FLOAT) DM CS GM K 11 K 14 Drain Motor Float Switch Geared Motor Name CN09(LOUVER) CN03 (SERIAL) (N) (L1) F CN10 (PUMP) K1~K14 Relay 43 CS K1 GM K1 ( output ) CN01 (TRANS) L K3 K2 BLK BLU ORN RED FM GRN/YEL WHI RC CN05 (TC) CN04 (TA) M H CN07 (FAN) VIO YEL BLU ORN UL VIO K4 REMOCON CN12 YEL TR RED Tel: 01823 665660 WHI Remote Controller TC TA Heronhill - for all your Toshiba requirements 3.4 RAV-132UH-PE Tel: 01823 665660 www.heronhill.co.uk F2 Power Supply 220/240V 50Hz Earth Screw F2 (1 Phase model) -26- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Power Supply 380/415V 3N 50Hz Earth Screw (3 Phase model) Outdoor unit Indoor unit Fan Motor Running Capacitor Transformer Sensor Sensor Fuse (PCB) RC TR TA TC F Name FM Symbol Spark Killer 43 DM DM CS GM K 11 K 14 K1 Drain Motor Float Switch Geared Motor Name CN09(LOUVER) CN11 (FLOAT) CN03 (SERIAL) (N) (L1) Relay F F CN10 (PUMP) K1~K14 Relay 43 Symbol 43 CS TR GM CN01 (TRANS) VIO K1 ( output ) K3 L K2 M H BLU ORN BLK RED YEL BLU ORN BLK UL K4 REMOCON CN12 GRN/YEL WHI RC CN05 (TC) CN04 (TA) CN07 (FAN) FM YEL RED TC TA 3.5 RAV-162UH-PE RAV-262UH-PE WHI Remote Controller Heronhill - for all your Toshiba requirements Tel: 01823 665660 Earth Screw www.heronhill.co.uk F2 (3 Phase model) -27- Fax: 01823 665807 Broken lines show wiring at site. Do not operate the units with magnetic contactor pushed in. Shows terminal block and figures show terminal numbers. Power Supply 380/415V 3N 50Hz Outdoor unit Indoor unit Remote Controller 43 Fan Motor Running Capacitor Transformer Sensor Sensor Fuse (PCB) RC TR TA TC F Name DM FM Symbol Spark Killer 43 CS Symbol Relay DM CS GM Name GM CN01 (TRANS) Drain Motor Float Switch Geared Motor K1~K14 Relay 43 K 11 K 14 K1 CN09(LOUVER) CN11 (FLOAT) CN03 (SERIAL) (N) (LI) F CN10 (PUMP) TR L K3 K2 M H WHI GRN/YEL GRY FM RED CN05 (TC) CN04 (TA) CN07 (FAN) YEL B L U ORN BLK UL RC K1 ( output ) K4 REMOCON CN12 TC TA Heronhill - for all your Toshiba requirements 3.6 RAV-362UH-PE RAV-462UH-PE Heronhill - for all your Toshiba requirements 3.7 RAV-162AH-PE Indoor unit Outdoor unit Earth Screw TR Earth F2 RY05 F Wave Control Circuit RY07 BLK TE TL BLU BLK WHI WHI RED BLK BLK 63H RED 52C GRY RED FM WHI 0 WHI RCO 26HD 20SF 20SR CM 52C RCC 51C Power Supply 220/240V 50Hz CH 1. Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Don't operate the units with magnetic contactor pushed. Symbol 20SF Name Solenoid Coil (4 Way Valve) RY05, 07 Relay 51C Overload Relay 20SR Solenoid Coil (2 Way Valve) RCc Running Capacitor (Compressor) RCo Running Capacitor (Fan motor) Symbol Name Symbol Name CM Compressor F2 Fuse (T5A) 52C Magnetic Contactor 63H High Pressure Switch FMo Fan Motor (Out door) CH Crank Case Heater TL Sensor F Fuse (on PCB) TE Sensor TR Transformer 26HD Bimetal Thermostat -28- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 3.8 RAV-262AH-PE Indoor unit Outdoor unit Earth Screw TR Earth F2 RY05 F Wave Control Circuit RY07 BLK TE TL BLU BLK WHI WHI RED BLK BLK 63H RED RED FM 52C GRY WHI WHI 0 RCO 26HD 20SF 20SR CM 52C RCC 49C Power Supply 220/240V 1. CH 50Hz Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Don't operate the units with magnetic contactor pushed. Symbol 20SF Name Solenoid Coil (4 Way Valve) RY05, 07 Relay 49C Inner Overload Relay 20SR Solenoid Coil (2 Way Valve) RCc Running Capacitor (Compressor) RCo Running Capacitor (Fan motor) Symbol Name Symbol Name CM Compressor F2 Fuse (T5A) 52C Magnetic Contactor 63H High Pressure Switch FMo Fan Motor (Out door) CH Crank Case Heater TL Sensor F Fuse (on PCB) TE Sensor TR Transformer 26HD Bimetal Thermostat -29- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 3.9 RAV-262AH8-PE Indoor unit Outdoor unit Earth Screw TR Earth F RY05 BLK Wave Control Circuit RY07 TE TL BLU BLK WHI WHI RED BLK 63H BLK RED RED 52C GRY FM WHI WHI 0 RCO 51C 47C F2 20SF 49C 47C CM 51C CH Power Supply 380-415V 3N 1. 50Hz 52C Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. 2. When the three phases are not connected correctly, the reverse phase protector operates and the unit will not start. In this case check the three phase wiring. Don't operate the units with magnetic contactor pushed. Symbol 20SF Name Solenoid Coil RY05, 07 Relay Symbol Name Symbol Name CM Compressor F2 Fuse (T5A) 52C Magnetic Contactor 63H High Pressure Switch FMo Fan Motor (Out door) CH Crank Case Heater 49C Inner Overload Relay 51C Overload Relay TL Sensor F Fuse (on PCB) 47C Reverse Phase Protector TE Sensor TR Transformer RCo Running Capacitor -30- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 3.10 RAV-362AH8-PE RAV-462AH8-PE Indoor unit Outdoor unit Earth Screw TR Earth F2 BLK F RY05 Wave Control Circuit RY07 TE TL BLU BLK WHI WHI RED BLK BLK RED RED FM 52C WHI GRY 01 WHI RC01 63H 51C BLK BLK GRY 20SF RED RED FM 49C WHI 02 WHI RC02 CM 51C CH Power Supply 380-415V 3N 50Hz 52C 1. Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Don't operate the units with magnetic contactor pushed. Symbol 20SF Name Solenoid Coil RY05, 07 Relay 49C Inner Overload Relay 51C Overload Relay RC01, 02 Running Capacitor Symbol Name Symbol Name CM Compressor 63H High Pressure Switch 52C Magnetic Contactor CH Crank Case Heater FM01, 02 Fan Motor (Out door) F Fuse (on PCB) TL Sensor TR Transformer TE Sensor F2 Fuse (T5A) -31- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4. SPECIFICATIONS OF ELECTRICAL PARTS 4.1 RAV-162BH-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 5 Indoor unit sensor for heatexchanger temp. 2 TYPE SPECIFICATIONS SMF-230-60-4A Output (Rated) 60W, 4 pole, 230V, 1 phase, 50Hz EEP2G405HQA ST-9586 AC 400V, 4µF 187~264V Maximum input 38mA DTN-C103J40 °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW Maximum input 34mA 62.29 32.82 25 50 10.0 3.59 4.2 RAV-262BH-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 5 Indoor unit sensor for heatexchanger temp. 2 TYPE SPECIFICATIONS STF-200-100-4 Output (Rated) 100W, 4 pole, 200V, 1 phase, 50Hz EAG40M505UF ST-9586 AC 400V, 5µF 187~264V Maximum input 38mA DTN-C103J40 °C KW Maximum input 34mA 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 4.3 RAV-362BH-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 5 Indoor unit sensor for heatexchanger temp. 2 TYPE SPECIFICATIONS STF-200-120-4 Output (Rated) 120W, 4 pole, 200V, 1 phase, 50Hz EAG40M505UF ST-9586 AC 400V, 5µF 187~264V Maximum input 38mA DTN-C103J40 °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW Maximum input 34mA 62.29 32.82 25 50 10.0 3.59 4.4 RAV-462BH-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 2 5 Indoor unit sensor for heatexchanger temp. TYPE SPECIFICATIONS STF-200-140-4F Output (Rated) 140W, 4 pole, 200V, 1 phase, 50Hz EAG40M106UF ST-9586 AC 400V, 10µF 187~264V Maximum input 38mA DTN-C103J40 Maximum input 34mA °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 -32- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.5 RAV-162CH-PE No. 1 PARTS NAME 4 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) Geared motor 5 Sensor for room temperature 2 3 Indoor unit sensor for heatexchanger temp. 6 TYPE SPECIFICATIONS SMF-230-34-4E Output (Rated) 34W, 4 pole, 230V, 1 phase, 50Hz EEP2W255HQ AC 400V, 2.5µF ST-9586 187~264V MT8-3-6 AC 240V, 3W Maximum input 38mA DTN-C103J40 °C KW Maximum input 34mA 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 4.6 RAV-262CH-PE No. 1 PARTS NAME 4 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) Geared motor 5 Sensor for room temperature 2 3 Indoor unit sensor for heatexchanger temp. 6 TYPE SPECIFICATIONS SMF-230-34-4D Output (Rated) 34W, 4 pole, 230V, 1 phase, 50Hz EEP2W255HQ AC 400V, 2.5µF ST-9586 187~264V MT8-3-6 AC 240V, 3W Maximum input 38mA DTN-C103J40 °C KW Maximum input 34mA 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 4.7 RAV-362CH-PE No. 1 PARTS NAME 4 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) Geared motor 5 Sensor for room temperature 6 Indoor unit sensor for heatexchanger temp. 2 3 TYPE SPECIFICATIONS SMF-230-75-4U Output (Rated) 75W, 4 pole, 230V, 1 phase, 50Hz EEP2W255HQ AC 400V, 2.5µF ST-9586 187~264V MT8-3-6 AC 240V, 3W Maximum input 38mA DTN-C103J40 °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW Maximum input 34mA 62.29 32.82 25 50 10.0 3.59 4.8 RAV-462CH-PE No. 1 PARTS NAME 4 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) Geared motor 5 Sensor for room temperature 6 Indoor unit sensor for heatexchanger temp. 2 3 TYPE SPECIFICATIONS SMF-230-75-4B Output (Rated) 75W, 4 pole, 230V, 1 phase, 50Hz EVM45M305UF AC 400V, 3µF ST-9586 187~264V MT8-3-6 AC 240V, 3W Maximum input 38mA DTN-C103J40 Maximum input 34mA °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW 62.29 32.82 25 50 10.0 3.59 -33- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.9 RAV-162KH(W)-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 5 Indoor unit sensor for heatexchanger temp. 2 TYPE SPECIFICATIONS AF-230-27-4P EEP2H155HQA ST-9586 Output (Rated) 27W, 4 pole, 230V, 1 phase, 50Hz AC 400V, 1.5µF 187~264V Maximum input 38mA DTN-C103J40 °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW Maximum input 34mA 62.29 32.82 25 50 10.0 3.59 4.10 RAV-262KH(W)-PE No. 1 PARTS NAME 3 Indoor unit fan motor Running capacitor for indoor fan motor Transformer (Indoor unit) 4 Sensor for room temperature 2 5 Indoor unit sensor for heatexchanger temp. TYPE SPECIFICATIONS AF-230-27-4R EEP2H155HQA ST-9586 Output (Rated) 27W, 4 pole, 230V, 1 phase, 50Hz AC 400V, 1.5µF 187~264V Maximum input 38mA DTN-C103J40 Maximum input 34mA °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 -34- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.11 RAV-132UH-PE, RAV-162UH-PE, RAV-262UH-PE No. 1 PARTS NAME 4 5 6 7 Indoor unit fan motor Running capacitor for indoor fan motor Transformer for Indoor unit Relay Geared motor Drain pump Float switch 8 Sensor for room temperature 9 Indoor unit sensor for heatexchanger temp. 2 3 TYPE SPECIFICATIONS SMF-230-45A EVM45M305UF Output (Rated) 45W, 6 pole, 1 phase, 230V, 50Hz AC 400V, 2.5µF ST-9586 AC187~264V LY2F MT8-3-3 PAD-416A34TF FS-085-003B AC240V, 2ab AC 240V, 3W AC230V, 0.2A AC230V, 0.5A Maximum input 38mA DTN-C103J40 °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW Maximum input 34mA 62.29 32.82 25 50 10.0 3.59 4.12 RAV-362UH-PE No. 1 PARTS NAME 4 5 6 7 Indoor unit fan motor Running capacitor for indoor fan motor Transformer for Indoor unit Relay Geared motor Drain pump Float switch 8 Sensor for room temperature 2 3 Indoor unit sensor for heatexchanger temp. 9 TYPE SPECIFICATIONS SMF-230-90-4A Output (Rated) 90W, 6 pole, 1 phase, 230V, 50Hz EVM45M305UF AC 450V, 3µF ST-9586 AC187~264V LY2F MT8-3-3 PAD-416A34TF FS-085-003B AC240V, 2ab AC 240V, 3W AC230V, 0.2A AC230V, 0.5A Maximum input 38mA DTN-C103J40 °C KW Maximum input 34mA 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 °C KW –12 0 25 50 10.0 3.59 62.29 32.82 4.13 RAV-462UH-PE No. 1 PARTS NAME 4 5 6 7 Indoor unit fan motor Running capacitor for indoor fan motor Transformer for Indoor unit Relay Geared motor Drain pump Float switch 8 Sensor for room temperature 9 Indoor unit sensor for heatexchanger temp. 2 3 TYPE SPECIFICATIONS SMF-230-90-4A Output (Rated) 90W, 6 pole, 1 phase, 230V, 50Hz EEP2G405HQ1 AC 400V, 4µF ST-9586 AC187~264V LY2F MT8-3-3 PAD-416A34TF FS-085-003B AC240V, 2ab AC 240V, 3W AC230V, 0.2A AC230V, 0.5A Maximum input 38mA DTN-C103J40 Maximum input 34mA °C KW 15 20 25 30 40 16.1 12.6 10.0 8.0 5.2 –12 0 °C KW 62.29 32.82 25 50 10.0 3.59 -35- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.14 RAV-162AH-PE No. PARTS NAME TYPE SPECIFICATIONS Compressor 2 Outdoor unit fan motor 3 Running capacitor for outdoor fan motor 4 Magnetic contactor 5 High pressure switch ACB-2TBO4W Tripping pressure 30kg/cm²G pressure 23kg/cm²G 6 Soleniod coil for four-way valve CHV-AC240V AC 220-240V 7 Crankcase heater AC 240V, 28W 8 Sensor for defrosting Maximum input 9 PH250X3-4LS Output (Rated) 2.0 kW, 2 pole, 220/240V, 1 phase, 50Hz 1 SMF-230-39N-2 Output (Rated) 39W, 6 pole, 230V, 1 phase, 50Hz EEP2G405HQ FMca-1S AC 220-240V, 50Hz Fuse Maximum input 15.5mA coil for two-way 11 Soleniod valve NEV AC 240V capacitor for 12 Running compressor MT-44MP456W 14 Overload relay 15.5mA Resetting °C KW –12 10 67.5 21.3 –12 10 67.5 21.3 5A for cooling operation 10 Sensor in low ambient temperature 13 Transformer (Outdoor unit) AC 400V, 4 µF FT-67 OL-177GM15 °C KW AC 220-240V, 50Hz AC 440V 45µF 187-264V AC 240V, Tripping temp: 165°C, Resetting temp: 80°C -36- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.15 RAV-262AH-PE No. PARTS NAME TYPE SPECIFICATIONS 1 Compressor (Rated) 2.2 kW, 2 pole, 3 phase, 220/240V, PH330X3-4MS Output 50Hz 2 Outdoor unit fan motor SMF-230-63N-2 Output (Rated) 63W, 6 pole, 1 phase, 230V, 50Hz 3 Running capacitor for outdoor fan motor 4 Magnetic contactor 5 High pressure switch ACB-2TBO4W Tripping pressure 30kg/cm²G pressure 23kg/cm²G 6 Soleniod coil for four-way valve CHV-AC240V AC 220~240V 7 Crankcase heater AC 240V, 28W 8 Sensor for defrosting Maximum input 9 EEP2G405HQ FMca-1S Fuse coil for two-way 12 Solenoid valve 13 Transformer for outdoor unit AC 220~240V, 50Hz 15.5mA Resetting °C KW –12 10 67.5 21.3 –12 10 67.5 21.3 5A for cooling operation 10 Sensor in low ambient temperature 11 Bimetal thermostat AC 400V, 4µF Maximum input 15.5mA CS-7 NEV202DXF FT-67 Tripping temp: 110°C 90°C °C KW Resetting temp: AC 220-240V, 50Hz AC 187~264V -37- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.16 RAV-262AH8-PE No. PARTS NAME TYPE SPECIFICATIONS YH330X3-MS Output (Rated) 2.2kW, 2 pole, 380~415V, 3 phase, 50Hz 1 Compressor 2 Outdoor unit fan motor 3 Running capacitor for outdoor fan motor 4 Magnetic contactor 5 High pressure switch ACB-2TBO4W Tripping pressure 30kg/cm²G pressure 23kg/cm²G 6 Soleniod coil for four-way valve CHV-AC240V AC 220~240V 7 Crankcase heater AC 240V, 28W 8 Sensor for defrosting Maximum input 9 SMF-230-63N-2 Output (Rated) 39W, 6 pole, 230V, 1 phase, 50Hz EEP2G405HQ FMSA-1 Fuse AC 400V, 4 µF AC 220V~240V, 50Hz, Tripping current: 7.5A, Resetting manual 15.5mA Resetting °C KW 10 67.5 21.3 –12 10 67.5 21.3 5A for cooling operation 10 Sensor in low ambient temperature Maximum input 15.5mA °C KW 11 Thermostat CS-7 Tripping temp: 120°C, Resetting temp: 90°C 12 Transformer FT-67 AC 187~264V STR 4AB AC 400/440V 13 R t –12 l k -38- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.17 RAV-362AH8-PE No. PARTS NAME TYPE SPECIFICATIONS Output (Rated) 3.0 kW, 2 pole, 3 phase 380/415V, 50Hz 1 Compressor YH406JA Winding resistance 2.88 W, at 20°C 2 SMF-230-63N-2 Output (Rated) 63W, 6 pole, 1 phase, 230V, 50Hz SMF-230-39N-2 Output (Rated) 39W, 6 pole, 1 phase, 230V, 50Hz Outdoor unit fan motor 3 Running capacitor for outdoor fan motor 4 Magnetic contactor 5 High pressure switch ACB-2TBO4W Tripping pressure 30kg/cm²G pressure 23kg/cm²G 6 Soleniod coil CHV-AC240V AC 220~240V 7 Crankcase heater AC 240V, 58W 8 Outdoor unit sensor for heat-exchanger temp. Maximum input 9 Transformer for outdoor unit EEP2G405HQA114 FMSA-1 FT-67 AC 400V, 4 µF AC 230V, 50Hz, Tripping current 9A, Resetting manual Resetting °C –12 10 KW 67.5 21.3 °C –12 10 KW 67.5 21.3 15.5mA AC 187~264V 10 Fuse 5A for cooling operation 11 Sensor in low ambient temperature Maximum input 15.5mA -39- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 4.18 RAV-462AH8-PE No. PARTS NAME TYPE SPECIFICATIONS Output (Rated) 3.75kW, 2 pole, 3 phase, 380/415V, 50Hz 1 Compressor YH506JA Winding resistance 2.29 W at 20°C 2 SMF-230-63N-2 Output (Rated) 63W, 6 pole, 1 phase, 230V, 50Hz SMF-230-39N-2 Output (Rated) 39W, 6 pole, 1 phase, 230V, 50Hz Outdoor unit fan motor 3 Running capacitor for outdoor fan motor 4 Magnetic contactor FMSA-1 5 High pressure switch ACB-2TBO4W Tripping pressure 30kg/cm²G pressure 23kg/cm²G 6 Soleniod coil CHV-AC240V AC 220~240V 7 Crankcase heater AC 240V, 58W 8 Outdoor unit sensor for heat-exchanger temp. Maximum input EEP2G405HQA114 FT-67 AC 400V, 4 µF AC 230V, 50Hz, Tripping current 12A, Resetting manual 9 Transformer for outdoor unit 10 Fuse 5A 11 Sensor for cooling operation in low ambient temperature Maximum input Resetting °C –12 10 KW 67.5 21.3 °C –12 10 KW 67.5 21.3 15.5mA AC 187~264V 15.5mA -40- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 5. REFRIGERANT PIPING DIAGRAM 5.1 Indoor unit RAV-132UH-PE Cooling Heating Indoor unit Distributor strainer capillary tube ø2.0 x 200l x 2P Heat exchanger Strainer Refrigerant pipe (Smaller side) ø6.4mm (1/4" ) Refrigerant pipe (Larger side) ø12.7mm (1/2" ) -41- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 5.2 Indoor unit RAV-162BH-PE RAV-162CH-PE RAV-162KH(W)-PE RAV-162UH-PE Outdoor unit RAV-162AH-PE Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer Refrigerant pipe (Smaller side) ø6.4mm (1/4") Refrigerant pipe (Larger side) ø12.7mm (1/2") Packed valve Packed valve Strainer Line Pressure Capillary tube ø2.4 x 500l x 1P Cooling High pressure Low P1 Heating Low pressure Dryer Expansion valve Check valve Heat exchanger TL sensor 2-way valve Distributor TE sensor Strainer Check joint Capillary tube ø0.8 x 1000l x 1P Four-way valve High pressure switch Accumulator Compressor Outdoor unit INDOOR UNIT OUTDOOR UNIT MODEL CAPILLARY RAV-162BH-PE RAV-162CH-PE RAV-162KH(W)RAV-162UH-PE IDø 2x200 lx3P IDø 1.7x400 lx4P IDø 1.7x200 lx2P MODEL MAIN CAPILLARY BYPASS CAPILLARY RAV-162AH-P IDø 2.4x500 lx1P IDø 0.8x1000 lx1P IDø 2x200 lx2P -42- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 5.3 Indoor unit RAV-262BH-PE RAV-262CH-PE RAV-262KH(W)-PE RAV-262UH-PE Outdoor unit RAV-262AH-PE Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer TC Sensor Refrigerant pipe (Smaller side) ø9.5mm (3/8" ) Refrigerant pipe (Larger side) ø15.9mm (5/8" ) Packed valve Packed valve Strainer Check Valve Capillary tube Dryer 2-way valve Check valve TL sensor Heat exchanger Distributor Expansion valve TE sensor Check joint Bypass capillary tube Strainer Four-way valve High pressure switch Accumulator Compressor Outdoor unit INDOOR UNIT MODEL CAPILLARY RAV-262BH-PE RAV-262CH-PE RAV-262KH(W)RAV-262UH-PE IDø 2x200 lx4P IDø 2.2x200 l x6P IDø 1.7x150 lx3P OUTDOOR UNIT MODEL MAIN CAPILLARY BYPASS CAPILLARY RAV-262AH-P IDø 2.6x900 l x1P IDø 1x500 lx1P IDø 1.7x400 lx4P -43- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 5.4 Indoor unit RAV-262BH-PE RAV-262CH-PE RAV-262KH(W)-PE RAV-262UH-PE Outdoor unit RAV-262AH8-PE Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer TC Sensor Refrigerant pipe (Smaller side) ø9.5mm (3/8") Refrigerant pipe (Larger side) ø15.9mm (5/8") Packed valve Packed valve Line Pressure Strainer Cooling High pressure Low P1 Check valve Capillary tube ø2.6 x 700l x 1P Heating Low pressure Dryer Expansion valve Check valve Heat exchanger TL sensor Distributor TE sensor Check joint Strainer Four-way valve High pressure switch Muffler Accumulator Compressor Outdoor unit INDOOR UNIT OUTDOOR UNIT MODEL CAPILLARY RAV-262BH-PE RAV-262CH-PE RAV-262KH(W)RAV-262UH-PE IDø 2x200 lx4P IDø 2.2x200 l x6P IDø 1.7x150 l x3P MODEL CAPILLARY RAV-262AH8- IDø 2.6x700 l x1P IDø 1.7x400 l x4P -44- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 5.5 Indoor unit RAV-362BH-PE RAV-362CH-PE RAV-362UH-PE RAV-462BH-PE RAV-462CH-PE RAV-462UH-PE Outdoor unit RAV-362AH8-PE RAV-462AH8-PE Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer TC Sensor Refrigerant pipe (Smaller side) ø9.5mm (3/8") Refrigerant pipe (Larger side) ø19mm (3/4") Packed valve Packed valve Line Pressure Strainer Cooling High pressure Low P1 Dryer Heating Low pressure Capillary tube Expansion valve Check valve Heat exchanger TL sensor Distributor TE sensor Check joint Strainer Bypass Capillary tube Accumulator Four-way valve High pressure switch Muffler Compressor Outdoor unit INDOOR UNIT OUTDOOR UNIT MODEL CAPILLARY RAV-362BH-PE RAV-362CH-PE RAV-362UH-PE RAV-462BH-PE RAV-462CH-PE RAV-462UH-PE IDø 2x400 l x6P IDø 2x300 l x7P MODEL MAIN CAPILLARY BYPASS CAPILLARY RAV-362AH8- IDø 2.4x650 lx1P IDø 1.7x1000 lx1P RAV-462AH8- IDø 3x600 lx1P IDø 2x1000 lx1P IDø 2x300 l x8P IDø 2.2x200 l x6P IDø 2x200 l x8P IDø 2x300 lx8P -45- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6. REMOTE CONTROLLER 6.1 -46-46- Remote controller BUTTON ON/OFF INDICATOR OPERATION LED (RED) Run/Stop AUTO Auto Changeover Cooling Heating Heating (with indoor fan operation at defrost) Fan only COOL MODE SELECT MODE HEAT 1 HEAT 2 FAN ONLY AUTO FAN Auto Fan Speed Control Low Fan Speed Med. Fan Speed High Fan Speed LOW MED HIGH Temperature setting TEMP. (1) CLOCK (2) ON TIME TIME ADJUST TIME (3) OFF TIME ON ON Timer OFF Timer ON → OFF Timer OFF TIMER SELECT TIMER (1) Present Time Adjust (2) ON Time setting (3) OFF Time setting ON → OFF OFF → ON Timer 24H CYCLE Timer ON ← OFF CYCLE -46- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.2 Outline of remote controller's functions NO 1 KEY SWITCH [ON/OFF] OUTLINE OF SPECIFICATION REMARKS When this button is pushed once, the air conditioner is turned on, with the operation lamp coming on. If pushed once more, it will be turned off, the operation lamp going off. If pushed for 5 sec. in the mode of turning on the air conditioner, goes into test run mode. 2 Each time this button is pushed, the [MODE] setting is changed over cyclically, [AUTO] Þ [COOL] Þ [HEAT1] Þ [HEAT2] Þ [FAN ONLY] Þ [AUTO]. MODE SELECT If pushed continuously, the setting will be changed in one step every 0.5 sec. 3 Each time this button is pushed, the [FAN] setting is changed over cyclically, [AUTO] Þ [LOW] Þ [MED] Þ [HIGH] Þ [AUTO]. Fan speed If pushed continuously, the setting will be changed in one step every 0.5 sec. 4 In the 18-29° Control range Each time [+] this button is pushed, the [TEMP] setting of temperature is raised by 1°C. + – If [+] is pushed continuously, the setting will be raised by 1°C every 0.5 sec. Each time [– ] button is pushed, the setting of temperature is lowered by 1°C. If [ – ] is pushed continuously, the setting will be lowered by 1°C every 0.5 sec. 5 Each time [TIME ADJUST] button is pushed, the [TIME] display is changed cyclically. The time can be changed while the TIME display stays flashing. [CLOCK] [12:00] TIME ADJUST + – TIME ADJUST Þ (flashing) [CLOCK] [12:00] Þ (flashing) [ON TIME] [6:00] Þ (flashing) [OFF TIME] [18:00] If time is not set, 12:00 16:00 18:00 are set automatically. While the TIME display stays flashing, the time gains one minute upon each pressing of [+]. If [+] is pushed continuously, the time gains 10 minutes every 0.25 sec. While the TIME display stays flashing, the time goes back one minute upon each pressing of [– ]. If [ – ] is pushed continuously the time goes back 10 minutes every 0.25 sec. Each time the [TIMER SELECT] button is pushed, timer mode changes over cyclically, [ ] (CONTINUE) Þ [ON] Þ [OFF] Þ [ON Þ OFF] Þ [ON OFF] Þ [CYCLE] Þ [ ]. Þ If pushed continuously, the timer mode will be changed in one stop every 0.5 sec. 6 CHECK Pressing this key for 0.5 sec. provides [MALFUNCTION CHECK], indicating on liquid crystal the contents of inspection in the sequence of (times of compressor-on) Þ (contents of malfunction for #1 unit) Þ (contents of malfunction for #2 unit) Þ ....... The indication of the indoor unit which has not any malfunction content is skipped. Pressing this key for 5 sec. gives “Indoor microcomputer reset mode” to reset the indoor microcomputer by way of hardware. Pressing this key for 10 sec. gives “Check contents clear mode” to clear the contents of inspection stored in the remote controller provided, however, times of compressor-on is not cleared. 7 Reset By pressing the reset key, the remote controller is reset by way of hardware. (The setting/display are in initial values with the check memory cleared.) -47- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.3 Timer operation Continuous operation and timer operations are available. The setting of timer operation can be done as follows: ON, OFF, ON Þ OFF, OFF Þ ON, ON Þ OFF CYCLE. Þ 6.3.1 Time display The present time is always displayed The display of the ON/OFF time is only in setting the time. Once set, it will not change even after carrying out the timer operation until the timer is reset Initial set time 6.3.2 The present time The time of ON The time of OFF 12:00 16:00 18:00 How to set the time Liquid crystal As to (– ) and (+), change takes place by one minute by pressing once and 10 min./0.25 sec. by pressing continuously. How to set the present time 1) [TIME ADJUST] switch is pressed. [CLOCK] and Time figures flash. 2) Time is set by Time setting switch (–) or (+). The setting is finished when (–) or (+) buttons are released. Pressing [TIME ADJUST] three times gives the display of the present time. (If left as it is, after 15 sec. the display will go back to the present time). How to set ON TIME 1) [TIME ADJUST] switch is pressed twice. [ON TIME] and Time figures flash. 2) Time is set by Time setting switch (–) or (+). The setting is finished when (–) or (+) buttons are released. Pressing [TIME ADJUST] twice gives the display of the present time. (If left as it is, after 15 sec. the display will go back to the present time). How to set OFF TIME 1) [TIME ADJUST] switch is pressed three times. [OFF TIME] and Time figures flash. 2) Time is set by Time setting switch (–) or (+). The setting is finished when (–) or (+) buttons are released. Pressing [TIME ADJUST] gives the display of the present time. (If left as it is, after 15 sec. the display will go back to the present time). -48- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.3.3 How to set the timer operation The following can be chosen sequentially by pressing [TIMER SELECT] switch: 1) [TIMER] ON 2) [TIMER] OFF 3) [TIMER] ON Þ OFF 4) [TIMER] ON OFF 5) [TIMER] CYCLE Þ Timer mode display l Be sure to set the present time. l In case of reoperating after finishing timer operation. If [TIMER SELECT] is not altered, the timer operation will be performed again. Timer ON operation 1) [TIMER] ON is applied. 2) ON/OFF key is pressed. Then LED is lighted. When the set [ON TIME] comes, the operation starts and OPERATION display appears on the liquid crystal, and the [TIMER] ON display goes off. 3) LED and OPERATION display goes off upon pressing ON/OFF key for stopping and [TIMER] ON is displayed. Timer OFF operation 1) [TIMER ] OFF is applied. 2) ON/OFF key is pressed. Then LED is lighted and the operation starts with OPERATION displayed on the liquid crystal. 3) When the set [OFF TIME] comes, the operation stops and the LED, OPERATION display goes off with [TIMER] OFF displayed. Þ Þ OFF timer operation Þ ON 1) [TIMER] ON Þ OFF or [TIMER] ON 2) ON/OFF key is pressed. LED comes on and the operation is performed as below: OFF is applied. ON Þ [TIMER] ON OFF Display [TIMER] ON Þ Display OFF Present time ON TIME [TIMER] ON Þ OFF [TIMER] OFF ON Present time OFF OFF OFF TIME [TIMER] ON Þ OFF OFF TIME [TIMER] ON Þ [TIMER] ON Þ OFF ON TIME [TIMER] ON OFF Pressing ON/OFF key Repeated operation 1) [TIMER] CYCLE is applied. 2) ON/OFF key is pressed. Then LED is lighted and ON Þ OFF timer operation is repeated according to the ON time and OFF time (repeating every day as it is a 24-hour timer). 3) The operation key is pressed. LED goes off and operation stops. Þ Timer stand-by display and operation display Waiting on the timer is displayed by LED lighting while the actual operation is displayed by OPERATION on liquid crystal. MODE SELECT FAN SELECT COOL OPERATION Displaying actual option HIGH -49- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.4 Malfunction check monitor 6.4.1 The times of compressor ON as well as the check code are displayed on the time display area by pressing CHECK key. [CHECK] switch Provides check code display by pressing for one second and indoor microcomputer reset by pressing for 5 seconds. * Unit No. Remote controller clear by pressing the key for 10 sec. Check code is cleared (normally not used). (a) Reset key (pushed by a needle and the like). Resetting remote controller (to the initial setting). Check code (a) Judgement from operation status 1. 2 3. 4. 5. 6. 7. 8. 9 OPERATION STATUS COD CAUSE Compressor stays off in cooling: it is not turned off in Open-circuit in room temperature heating. sensor. Compressor stays off in heating: it is not turned off in 0C Short-circuit in room temperature cooling. sensor. Open-ciruit in indoor heat-exchanger Indoor fan stays off in heating. sensor. 0d Outdoor fan continues ON-OFF operation in Short-circuit in indoor heat-exchanger heating. sensor. Though indoor unit operates, outdoor unit remains in connecting cable 04 Abnormality off. between indoor and outdoor units. 4-way valve coil burnt out, pipe Indoor fan does not work in heating operation. 08 clogged, abnormality in indoor Warm air comes out in cooling operation. heat-exchange sensor. Refridgerant gas in shortage. Indoor fan at LOW speed in cooling operation with 09 abnormality in indoor heat-exchange the outdoor remaining in stoppage. sensor. or short-circuit in outdoor TE Full stop 18 Open sensor. or short-circuit in indoor TL Full stop 19 Open sensor. switch does not reset within Full stop 21 Pressure the set time. Abnormality in connecting cable I d it d t t t ll 99 b t t * Witht drain ll pumpd units i d only Note : If the red LED on the remote controller does not flash when the system is switched on, then the wiring to the outdoor unit needs to be checked to ensure that the three phases are wired in the correct sequence. (RAV-262AH8 unit only.) -50- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.4.2 How to read malfunction check monitor display By pressing [CHECK] key, times of No. 1 unit compressor-ON actuations as well as the check code information of 2 faults x 16 units are displayed on the time display area. (2 sec. per one phenomenon) < Times of compressor-ON > Ex. in case of the number of times of compressor actuations of 164. Display in 4 digits of hexadecimal notation 163 x 0 + 162 x 0 + 16 x 10 + 4 = 164 Display in 7 segments hexadecimal digit decimal digit < Check code information > Unit number The first detected Check code Ex. In case of room temperature sensor of No. 1 unit in trouble. For No. 15 unit, firstly heat exchanger temperature sensor and secondly float switch circuit are faulty. The last detected No display is made if there is no fault. -51- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.4.3 List of Check Codes ROOM TEMP. SENSOR (TA). Operation continuing 1. 2. Check the indoor temp. sensor. Check the indoor PC board. Operation continuing 1. 2. Check the indoor heat-exchanger sensor. Check the indoor PC board. Operation continuing 1. 2. If outdoor unit does not work at all. (1) Check the connecting cable correct wrong wiring. (2) Check the outdoor PC board. If operates normally. Between indoor terminal plates 2 and 3, return signal is: Available: Check the indoor PC board. Not available: Check the outdoor PC board. Operation continuing 1. 2. 3. 4. Check the 4-way valve. Check the 2-way valve and check valve. Fault with indoor heat exchanger sensor. Check the indoor PC board. Operation continuing 1. Compressor case thermostat, IOL, OL operation. (contactor OFF, compressor stops: AH8 Models) (contactor ON, compressor stops: AH Models) Indoor heat-exchange sensor out of place. Check the indoor PC board. Check that service valves are OPEN. Out of place, break, short-circuit. INDOOR HEAT-EXCHANGER SENSOR (TC). Out of place, break, short-circuit. RETURN SIGNAL NOT COMING TO INDOOR 1) Wrong wiring in connecting cable (serial signal). 4-WAY VALVE SYSTEM 1) Indoor heat-exchanger temperature rises, after starting cooling operation. 2) Indoor heat-exchanger temperature drops after starting heating operation. OTHER CYCLE SYSTEM 1) Indoor heat exchange temperature does not change after starting cooling/heating operation. 2) When transmitting instruction for stopping compressor by freeze preventing control. DEFROST SENSOR (TE) 2. 3. 4. Outdoor unit stops 1. (indoor fan L) 2. 1. 2. Full stop Check the charged amount of refrigerant gas. (Gas shortage → gas supplement, check for gas leaks) Indoor fan locked. Check the defrosting sensor. Check the outdoor PC board. Out of place, break, shortcircuit. -52- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements OUTDOOR HEAT-EXCHANGER SENSOR (TL) Full stop 1. 2. Check the outdoor heat-exchanger sensor. Check the outdoor PC board. Full stop 1. 2. Check the high pressure switch. Check the outdoor PC board. Full stop 1. 2. Check the compressor. Check the wiring of compressor. (lack of phase, short circuit) Check the voltage. Check the outdoor PC board. Out of place, break, short-circuit. HIGH PRESSURE SWITCH High pressure switch does not reset. 5 sec in cooling 30 sec in heating OTHER ABNORMALITY OF OUTDOOR UNIT 3. 4. Compressor does not operate. Start once, but soon after stop by OCR WRONG WIRING OF REMOTE CONTROL UNIT Full stop 1. 2. Check the wiring between remote control unit and indoor unit. Check the indoor unit PC board. Indoor unit does not operate at all. FLOAT SWITCH Outdoor unit stops 1. 2. 3. Float circuit out of position, break. Fault in drain pump. Drain pipe clogged. Check for indoor PC board. * With drain pump unit only. -53- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 6.5 Malfunction check 6.5.1 Using LED display on outdoor PC board LED display vs. check code Dip switch settings (DSW01) LED 1 (RED) 2 (YELLOW) 3 (YELLOW) Table-1 4 (YELLOW) 21 High pressure switch fault 18 Temp. sensor (TE) faulty 19 Temperature sensors TD/TL open/short circuit. Table-2 Number of protective device operations Table-3 Serial input data Table-4 Serial output data POSITIONS OF DIP SWITCH AND LED Dip Switch (SW01) PC Board LED D04 (orn) Serial input D05 (grn) Serial output -54- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements <Table-1> Dip switch settings LED 1 2 3 Judgement 4 Normal operation Timer short Full stop 21 High pressure switch fault 18, 19 Fault codes (Refer to Table-2) <Table-2> Dip switch settings LED 1 2 3 Judgement 4 Normal operation Number of protective device operations: one Number of protective device operations: two Number of protective device operations: three LEDs 3 & 4 flashing (1Hz) faults shown below. Number of protective device operations: four 18 Temperature sensor (TE) faulty 19 Temperature sensors (TD/TL) open/short circuit Full stop 21 Hi h ressure switch fault LED Status : on : :5Hz flash : :1Hz flash : off -55- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements <Table-3> Dip switch settings LED 1 2 3 Status of compressor 4 Stop Operating <Table-4> Dip switch settings LED 1 2 3 Status of compressor 4 Stop Operating -56- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 7. OUTLINE OF CONTROL CIRCUIT NO ITEM 1 Discrimination 2 Operation change-over OUTLINE REMARKS OUTLINE OF CONTROL Stopping air conditioner Performing automatic change-over Performing cooling operation Performing heating operation Performing heating operation with indoor fan operation at defrosting Heat 2 Fan only Controlling room temperature SPECIFICATIONS Operation mode is changed over according to operation mode select instruction from the remote controller. REMOTE CONTROLLER INSTRUCTION Stop Auto Cool Heat 1 3 OF Discrimination of outdoor unit is performed either in the reset of power source or when stopping from operating condition, and the controlling is changed over in accordance with the result of discrimination. Performing fan only operation 3-1 Adjusting range (°C) In cooling In heating Remote controller setting temperature 18 ~ 29 18 ~ 29 Operating temperature 18 ~ 29 20 ~ 31 3-2 Operating point is compressor - off. 3-3 Operating temperature accuracy: ± 1°C 3-4 Differential: 1 deg Correcting temperature compensation 3-5 Room temperature controlled in the heating operation can be corrected by 3-5 dip switch of indoor microcomputer. Dip switch Setting 1 2 Control temperature compensation ON ON ON OFF 0 deg 2 deg OFF ON OFF OFF 4 deg 6 deg Ts (Max) = 35°C -57- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements NO. 4 ITEM Fan speed control 4-1 4-2 4-2 4-3 4-2 OUTLINE OF SPECIFICATIONS REMARKS [HIGH], [MED], [LOW] and [AUTO] are available. [Ultra low] or [Stop] when compressor is turned off while heating is being performed. In the auto fan, the fan speed is changed by the difference between Ta and Ts, as shown below. [Stop] is cold draft prevented by Tc. -Cooling- 5 6 Cold draft preventing control Freeze preventing control (Low temp. release) -Heating- -Auto-changeover- When performing heating operation, indoor fan control is carried out as follows based on temperature detection of Tc sensor. C zone: Depending upon fan speed setting of the remote controller B zone: Indoor fan at “L” A zone: Fan stop When performing cooling operation, the following control is done based on temperature detection of Tc sensor. When starting the operation, the point P is made +3°C. When [J] zone is detected, timer counting starts. When [K] zone is detected, timer counting is discontinued and held on. When [I] zone is detected, timer is cleareed for returning back to ordinary operation. When timer counting becomes full time, the ourdooor unit stops and the point P is changed to +12°C to be covered by check display. When [I] zone is reached, the temperature is returned back to +3°C. Full Time MIN 7 min. MAX 20 min. -58- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements NO. 7 ITEM High temperature release control OUTLINE OF SPECIFICATIONS REMARKS When performing heating operation, the following control is done based on temperature detection of Tc sensor. In [M] zone, release signal is transmitted. Outdoor fan is controlled in accordance with the diagrams below The control point for A and C can be chosen from the below table: Dip Switch Setting 3 4 ON A/C (°C) ON ON OFF 54/52 58/56 OFF ON OFF OFF 60/58 L–α=0 (fan stop) Single release Release ON ON Release signal OFF Outdoor fan Release OFF For 3 minutes For 20 minutes H H-1 Reset operation L–α Duplicate release Release ON Release OFF ON Release signal OFF Outdoor fan For 20 minutes or less For 20 minutes or less For 3 minutes H H-1 H-2 H-3 L–α Reset operation Release ON Release OFF ON Release signal OFF Outdoor fan H H-1 H-2 H-3 For 20 minutes For 20 minutes For 20 minutes For 20 minutes Normal operation L–α When the high temperature release is received, the release control continues for 3 minutes at least even if release is performed on the way, and H-1 is performed for 20 minutes and the machine returns to normal operation. When the release signal continues for more than 3 minutes, H-1 operation of outdoor fan control is performed at the same time as releasing the release and the machine returns to normal operation. When the high temperature release is received during operation of H-1 for 20 minutes, operation of the previous time –1 of reset operation is performed for 20 minutes after release operation. If the release signal is not received during reset operation for 20 minutes, reset operation of +1 per 20 minutes is performed and the machine returns to normal operation. The high temperature release control is ignored during defrosting operation. Release of H–α discontinued:When stopping operation When changing over operation -59- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements NO. ITEM OUTLINE OF SPECIFICATIONS REMARKS 8 Residual heat removal When stoppage takes place in [HEAT 2] operation, indoor fan is operated in [LOW] for 30 sec. 9 Test operation If Remote controller's ON/OFF switch is pressed 5 seconds continuously, the unit goes into test run mode with the indoor fan in the [HIGH]. 10 High pressure release The following control is performed when high pressure switch of the outdoor unit is actuated. In cooling operation Compressor is turned off and if the high pressure switch does not reset for 5 seconds continuously thereafter, it is judged abnormal. In heating operation Compressor is turned off and if the high pressure switch does not reset for 30 seconds continuously thereafter, it is judged abnormal. If the switch resets within 30 sec., the compressor restarts 2 minutes and 20 sec. later and operates according to the diagram below. <Outdoor unit control> LED lamp comes on in abnormal condition, with abnormal code transmitted to indoor unit. 2 minutes and 20 sec. Compressor Outdoor fan ON OFF 120 sec. 30 sec. L–a=0 (fan stops) H L–a * W h e n t h e o u t d o o r f a n H i s r e s t r i c t e d t o ( H – a) i n t h e h i g h * t e m p e r a t u r e r e l e a s e , H i n t h e a b o v e f i g u r e i s ( H – a). In defrosting operation Compressor is turned off, the operation returning back to heating operation. 11 Protection at the time of Mg-SW fusing 12 Defrosting 12-1 In heating operation, defrosting 12-1 is made based on outdoor heat 12-1 exchange temperature Te. 12-2 When cumulative working time 12-2 of the compressor in [A] zone 12-2 has amounted to 55 minutes, 12-2 defrosting operation starts. 12-2 (25 minutes initially) 12-3 The longest defrosting time is 12-3 12 minutes, 60 sec. in the case 12-3 of turning into [B] zone, and 12-3 immediate returning back when 12-3 [C] zone is reached 13 Four-way valve reversal control The following control shall be performed when the compressor stops: The 4-way valve in the hold state shall be reversed 10 seconds before the restart delay timer counts the maximum count (2 minutes 20 seconds). After the restart delay timer counts the maximum value, the specified mode shall be selected. If the high pressure SW continues to operate for 5 seconds while the compressor is stopping, fusing of Mg-SW is detected and the outdoor fan is controlled as described below. When the four-way valve is OFF (including during defrosting operation) Turn ON the outdoor fan using “H”. When the four-way valve is ON Turn OFF the outdoor fan. (When the compressor is stopping, the outdoor fan should be OFF) <Outdoor unit control> -60- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements N ITEM 14 Low ambient cooling OUTLINE OF SPECIFICATIONS REMARKS <Outdoor unit control> 14-1 Control on outdoor fan is made TL sensor 14-1 to meet with cooling at low outdoor 14-1 temperature based on outdoor heat 14-1 exchange temperature TL. 14-2 Control by outdoor heat 14-2 exchange temperature TL 14-2 is illustrated on the right. 14-3 For first 2 minutes after starting 14-3 cooling operation the fan(s) 14-3 operate in “H” speed. +1 wave,–1 wave is (current number of waves) ± (1 wave) Air quantity A Zone H 1 minute and 30 B Zone Per sec. +1 wave Air quantity “M” automatic control C Zone Maintain D Zone – Per 20 sec. 1 wave Timer accuracy: 20 1 minute and 30 15 Check display +0 -10 +0 -10 sec. sec. Fault diagnosis is carried out by check for serial transmission and reception with outdoor unit as well as the self check by indoor microcomputer. And check code is transmitted to protective operation/remote controller based on the contents of it. In the remote controller, check code is displayed on the liquid crystal by pressing [CHECK] key. See other item: Using [TIME] display Unit NO. 16 Anti-restart timer 17 Group operation control Check code The outdoor unit delays restarting for 2 mins 20s to prevent short cycling compressor operation. Up to 16 units can be controlled in same setting condition by one remote controller. However, thermo-control function is independent. Respective delayed start time for preventing simultaneous large starting current can be obtained by different setting of the unit No. switch on the indoor PC board. -61- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 8. DESCRIPTION OF INDOOR UNIT CONTROL CIRCUIT 8.1 Serial signal indoor units) circuit (between outdoor SERIAL/ COMP and This is a circuit for transmitting and receiving the signals between the indoor and outdoor units in serial signal. As 230V is used for transmitting the signal, the microcomputer section is insulated by means of photo-coupler with the voltage reduced to 5V. CN03 WHI With AC interrupt, judgement is made as to the presence or absence of serial signal based on the reference pulse taken out from the voltage across R and S. AC interrupt Serial signal AC interrupt Serial input AC interrupt Serial input Serial output Float switch Blk / 8.2 ... are measurement points on the printed circuit board. provides flashing (orange) on LED in the serial input. Float switch circuit In normal condition in which float switch is not operated, 230V is applied across the pins 1 and 2. At this time, point is at the GND level. If the float switch is operated, will be at the level of 5V. -62- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 8.3 Sensor circuit This circuit detects the temperature by dividing voltage with resistance and sensor and bringing the voltage value into CPU, using the characteristics of the sensor that resistance varies with different temperatures. TA and TC have the /same circuit composition. TA sensor TC sensor When TA and TC are at 25°C approximately, the voltage level is some 2V both at points abnormal condition prevails such as opening or short-circuit of the sensor. 8.4 and . If / are at GND or 5V, 12V power source circuit Full-wave rectification by diode bridge (DB01) of alternate current supplied from power transformer followed by the provision of transistor (Q01) gives DC12V power source ( ). 8.5 5V watchdog timer circuit Built-in IC (TA8000S) is used to produce 5V power source ( ). Also, it sends signals to reset port ( ) of microcomputer which is in stand-by at 0V and starts its operation with the signal of 5V. Watchdog timer output ( ) gives the signal from microcomputer as illustrated below. This indicates that the microcomputer is working in normal routine. For example if the microcomputer is straying due to noise and so on, this waveform is not produced. In case there is no waveform, it plays the role of restoring normal condition by inputting the resetting “0V”+ to the microcomputer. To microprocessor Reset input Watchdog output 5V Watchdog timer output 0V 8.6 2~10m sec. Reset circuit This circuit makes indoor microcomputer reset by way of hardware when you keep pressing the check key of remote controller for longer than a predetermined period. It plays the role of resetting microcomputer from the remote controller when it strays. The point ( ), which is normally at the level of 5V drops down to the GND level in the reset operation. Serial input from remote controller -63- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 8.7 Serial signal circuit (Between remote controller and indoor unit) This is the circuit for transmitting and receiving the signals between the remote controller and indoor unit in serial signal. Point is a LED (green) which flashes when there are signals from the remote controller. At as illustrated below are output. 8.8 and , the signals Optional circuit A circuit which allows for the take-out of the signals of abnormal, operation and Compressor-ON. Point is a LED which lights at abnormal. The connector pin 4 outputs 12V. When you want to see the signal of compressor-ON, you can do it simply with the circuit below. Abnormal Operation Compressor ON Comp -64- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements Heater Fan Control Output Louver Output Drain pump RY14 G4U-1 RY07 G4U-1 RY02 AJE6412 RY03 AJE6412 RY01 AJE6412 RY13 G4U-1 RY11 G4U-1 8.9 To CPU D15 155176 Relay circuit The relay circuit consists of the diagram above. The relay performs the following functions: RY01 : Main switching relay RY02 : Changing over H/M of fan RY03 : L tap of fan RY04 : UL tap of fan RY11 : Turning louver on and off RY14 : Turning drain pump on and off ( - ) To CPU TA Shift TC Shift Unit Number 8.10 Model Change Switch circuit TA shift, TC shift and unit No. are changed over by the switch. TA shift and TC shift are set in factory with unit No. at “1”. In servicing, the setting should be made to the same TA/TC shift as the PC board attached originally. In case of operating one single unit, unit No. “1” will do. With the operation of many units (multi units control) the unit No. should be adjusted in such a way as 1, 2, 3 ........ -65- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements AC 240V 9.3 12V power source circuit Outdoor PC board produces full-wave rectification by diode bridge (DB50) followed by the provision of transistor (Q50) produces DC power source ( ) at 12V. 9.4 9.5 5V watchdog timer circuit Watchdog timer output Basically, the same description as the indoor PC board applies, provided, however, that the reset circuit is not added to the outdoor side. Reset input Sensor circuit This circuit detects the temperature by dividing voltage with resistance and sensor and bringing the voltage value into CPU, using the characteristics of the sensor that resistance varies with different temperatures. TE is for defrosting, while TL is for low ambient cooling operation. The following voltages are produced at each of the temperatures. 250 C 00 C TE 2.3V 3.8V TL 2.3V 3.8V When / are at GND or 5V, the sensors are either open or short-circuited. To CPU -70- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 9.6 Serial signal circuit (between indoor and outdoor units) Transmits and receives the signals between indoor and outdoor units in serial signals. As 230V is used for transmitting the signal, the microcomputer section is insulated with photo-coupler with 5V being supplied. (L) AC (N) Serial Input 5V Serial input 0 Output 5V 0 9.7 Serial output Abnormality-detecting circuit When high pressure switch is operated, abnormality is detected to stop the compressor. Abnormal input abnormal input 9.8 Relay circuit The relay circuit consists of the diagram on the right-hand side. RY05 : RY07 : High Pressure Switch 4-way valve ON/OFF Magnetic switch ON/OFF Relay control circuit -71- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 9.9 Fan speed control circuit To CPU The fan speeds are controlled by triac IC07. This allows the fan to operate at any one of 16 speeds. This function only occurs when the unit is in the cooling mode, zero waves equates to fan stop. and T. Waveform obtained between Example shown is for 4 waves. WHI RED WHI (Wiring for 2 fan motors) 16 waves 9.10 Lightning surge protection circuit The circuit on the right, protects the PCB from damage caused by a lightning surge. Varistors are connected between the live and neutral and live and earth lines to protect against voltage surges. I N -72- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 10. OPERATION OF AIR CONDITIONER FROM OUTDOOR UNIT It is possible to operate the air conditioner from the outdoor unit using switches provided on the outdoor PCB. • ‚ Set dip-switch (DSW01) bits 1 & 2 to ON position. STOP 10 OPERATION (orange LED off → orange LED flashing) Apply Short a short across CN28 and CN29 until D08 Led illuminate, remove the short. The led will then extinguish and the indoor unit will start. After a couple of minutes the outdoor unit will start, LEDs D07 and D10 will illuminate. OPERATION STOP (orange LED flashing → orange LED off) Short pins CN28 with CN29, LEDs D08 and D10 will extinguish. After indoor unit has stopped D07 will extinguish. ƒ Reset DSW01 bits 1 & 2 to OFF position for normal operation. -73- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 11. EMERGENCY OPERATION If the air conditioner develops a fault which stops it from operating normally, it is possible to operate the air conditioner using change-over connectors incorporated into the units. In this case, operation of the air conditioner is controlled by switching on and off the power supply. Details of how to change-over the units to operate in the emergency mode are shown below: • ‚ Switch off the power supply to the outdoor unit. Remove the electrical parts cover from the indoor unit. Pull out the connector of R phase (red) lead wire from terminal connect it with the connector of lead wire for fan motor K1 output (red). • and Note : If the indoor unit is a cassette model, the float switch connector must be removed from the PCB. Replace the electrical parts cover on the indoor unit. On the outdoor unit PCB, change the switch settings on dip switch DSW01 as follows: Cooling Mode ƒ Heating Mode Switch on the power supply to the outdoor unit. -74- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 12. APPLIED CIRCUIT (1) Display output CN13 An auxiliary display output circuit (+12V) is available at CN13 on the Indoor PC Board to display the operation for compressor, operation (Fan only) and abnormality. Compressor Operation (Fan only) Abnormality LED (Provide Locally) 13. WIRING FOR GROUP OPERATION Up to 16 units can be controlled as a group by one remote controller. • ‚ ƒ Align the phase sequence of the power supply to all outdoor units. Connect the terminals A, B, C on both of the remote controller and the indoor unit of No. 1 unit. Connect terminals B, C on both indoor units of No. 1 and No. 2 unit. Then connect in the same way No. 2 and No. 3, No. 3 and No. 4 .... up to No. 16 unit. Indoor unit No. 1 Indoor unit No. 2 Indoor unit No. 3 Indoor unit No. 16 Make sure of correspondence of terminal marks. Remote controller „ Remove the CN12-connector on the indoor PC board of No. 2 unit and up to No. 16 unit to prevent malfunction. CN 12 … CN01 Set each unit No. rotary switch on the indoor PC board. The unit connected to the remote controller should be set as No. 1 unit. Then set No. 2 and up to No. 16 so that start time of each unit is respectively delayed to prevent simultaneous starting current. CN 12 Rotary switch SW 02 SW 01 -75- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 14. PERFORMANCE CHARACTER 14.1 Cooling capacity Capacity Ratio (%) RAV-162AH-PE Ambient Temp. (Dry Bulb) ( o C) 3.60 3.82 4.05 4.28 4.50 4.73 4.95 5.18 5.40 (KW) RAV-262AH-PE RAV-362AH8-PE RAV-462AH8-PE RAV-262AH8-PE 5.68 6.04 6.39 6.75 7.10 7.46 7.81 8.17 8.52 8.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 10.00 10.63 11.25 11.88 12.50 13.13 13.75 14.38 15.00 Room Temp. (Wet Bulb) (o C) 14.2 Heating capacity Capacity Ratio (%) RAV-162AH-PE Ambient Temp. (Wet Bulb) ( o C) 6.00 5.75 5.50 5.25 5.00 4.75 4.50 4.25 4.00 3.75 3.50 3.25 3.00 2.75 Room Temp. (Dry Bulb) (o C) (KW) RAV-262AH-PE RAV-362AH8-PE RAV-462AH8-PE RAV-262AH8-PE 9.48 9.09 8.69 8.30 7.90 7.51 7.11 6.72 6.32 5.93 5.53 5.14 4.74 4.35 12.96 12.42 11.88 11.34 10.80 10.26 9.72 9.18 8.64 4.10 7.56 7.02 6.48 5.94 16.56 15.87 15.18 14.49 13.80 13.11 12.42 11.73 11.03 10.35 9.66 8.97 8.28 7.59 -76- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 14.1 Cooling capacity RAV-162AH-PE RAV-262AH-PE RAV-262AH8-PE Cooling Capacity Ratio Heating Capacity Ratio Outdoor Unit Height H (m) Outdoor Unit Height H (m) Indoor Unit Outdoor Unit Piping Length (m) Piping Length (m) RAV-362AH8-PE RAV-462AH8-PE Heating Capacity Ratio Outdoor Unit Height H (m) Outdoor Unit Height H (m) Cooling Capacity Ratio Piping Length (m) Piping Length (m) The broken line shows in case the piping length is 30m or less. -77- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 14.4 Piping length/additional refrigerant volume Piping length less than (m) 20 Model (RAV-) Additional amount of refrigerant at installation site (kg) 25 162AH-PE 262AH-PE 262AH8-PE 362AH8-PE Filled at factory 462AH8-PE 30 35 40 45 50 Recharge amount of interchange time (kg) 5 10 15 20 25 30 0.15 0.35 1.35 1.45 1.5 1.6 1.75 1.95 0.3 0.6 2.2 2.25 2.3 2.35 2.65 2.95 35 40 45 50 0.25 0.5 0.75 1.0 1.25 1.5 3.0 3.15 3.25 3.4 3.65 3.9 4.15 4.4 4.65 4.9 0.25 0.5 0.75 1.0 1.25 1.5 3.6 3.7 3.8 3.9 4.15 4.4 4.65 4.9 5.15 5.4 l The amount of refrigerant put into the outdoor unit at the factory is equivalent to the one that fills up 20m length of refrigerant pipe. l If the length of refrigerant pipe is 20m or less, addition of refrigerant at the installation site is unnecessary. If the length of the pipe exceeds 20m, add the refrigerant R-22. l Overcharge or undercharge of refrigerant in the outdoor unit will cause malfunction of the compressor. The prescribed amount of the replenishment of the refrigerant is shown in the table above. The permissible amount of refrigerant is the prescribed amount ±50g. l For RAV-362AH8-PE and RAV-462AH8-PE, the length of pipe exceeds 30m the size of pipe at the gas side must be raised one rank (eq 19.0 → 22.2). 14.5 Air flow distribution RAV-132UH-PE RAV-162UH-PE RAV-262UH-PE RAV-362UH-PE RAV-462UH-PE Piping joint Top view Indoor Unit Ceilling panel Not to block the A and B direction (longer side). Air flow direction & volume ratio MODEL RAV-132/162/262UH-PE RAV-362/462UH-PE No. of discharge way Air flow direction Air volume ratio (%) Air volume ratio (%) A 30 40 4-way B C 30 30 40 10 (Note) When installing more than one unit in the same room keep a 5m distance between each unit. D 10 10 3-way A B C 33 33 33 40 40 20 2-way A B 50 50 50 50 5m -78- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15. EXPLODED VIEWS AND PARTS LISTS 15.1 Indoor Unit RAV-162BH-PE RAV-262BH-PE RAV-362BH-PE RAV-462BH-PE Location No. Part No. 2 01 43160394 Connector-9P 202 43019604 Holder, Sensor 43155096 Capacitor, Electrolytic (RAV-262/362BH-PE) 203 4 31 2 01 4 9 Fan, Multi-Blade 43155097 Capacitor, Electrolytic (RAV-462BH-PE) 204 43A21009 M o tor, F a n (R AV -16 2 BH -PE ) 211 43A58002 Transtormer, Power 4 312 151 6 M o to r, Fa n (R AV -2 62 B H -P E ) 212 43A60001 Terminal, 4P 4 31 2 15 2 8 M o to r, Fa n (R AV -3 62 B H -P E ) 213 43A62001 Cover, Remocon 4 31 2 15 3 5 M o to r, Fa n (R AV -4 62 B H -P E ) 214 43A69002 PC, Board 43A44002 Ev a p ora to r (R AV -1 62 B H -P E ) 215 43A60002 Terminal, 3P 43144679 Ev a p ora tor (R AV -2 62 B H -P E ) 216 43191304 Drain Pan (RAV-162BH-PE) 43144692 Ev a p ora tor (R AV -3 62 B H -P E ) (R AV -4 62 B H -P E ) 43191305 Drain Pan (RAV-262BH-PE) 43191310 Drain Pan (RAV-362/462BH-PE) 205 206 Location No. Description 210 43144693 Ev a p ora tor 43A47001 Distributor (strainer) (RAV-162BH-PE) 43147443 Distributor (strainer) (RAV-262BH-PE) 43147532 Distributor (strainer) (RAV-362BH-PE) 43147533 Distributor (strainer) (RAV-462BH-PE) 207 43050377 S e n s o r (T A ) 208 4 31 5 01 9 9 S e n s o r (T C ) 209 43A69004 Remote Controller 217 Part No. Description 43155080 Capacitor, Electrolytic 43047527 Capillary Tube. 2.0DIA (RAV-162/262/362BH-PE) 43146432 Capillary Tube. 218 (RAV-162BH-PE) (RAV-462BH-PE) 42125135 Bearing 219 43125137 Coupling 220 43A88002 Manual -79- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.2 Indoor Unit RAV-162CH-PE RAV-262CH-PE RAV-362CH-PE RAV-462CH-PE Location No. Part No. Description Location No. Part No. 43144639 A s m E v a p o ra tor (RAV-162CH-PE) Description 201 4 3 10 7 21 4 Hinge 223 202 4 3 10 7 21 5 Sensor Fix Plate 223 43A44004 A s m E v a p o ra tor (RAV-262CH-PE) 203 4 3 10 7 21 6 Spring 223 431A4005 A s m E v a p o ra tor (RAV-362CH-PE) 204 43107223 Grille Shaft Left 223 43144650 A s m E v a p o ra tor 205 43107222 Grille Shaft Right 224 4 3 15 5 13 8 MF Capacitor (RAV-162/262/362CH-PE) 206 43107224 Grille Support Centre (RAV-462CH-PE) 207 4 3 10 9 32 1 In le t G rille L a rg e 208 43109322 In le t G rille S m a ll 209 43109324 H G rille A s m (RAV-362/462CH-PE) 224 4 3 15 5 12 0 MF Capacitor 225 43A69004 Remote Control (RAV-462CH-PE) 226 4 3 17 0 19 7 A s m H os e (RAV-162CH-PE) 227 4 31 721 21 A s m D ra in P a n (RAV-162CH-PE) 4 31 721 19 A s m D ra in P a n (RAV-262CH-PE) 209 43109320 H G rille A s m (RAV-262CH-PE) 227 209 43109327 H G rille A s m (RAV-362CH-PE) 227 4 3 17 2 12 2 A s m D ra in P a n (RAV-362CH-PE) (RAV-462CH-PE) 227 4 3 17 2 12 3 A s m D ra in P a n (RAV-462CH-PE) Plug 209 43109328 H G rille A s m 210 43109329 Vertical Grille 228 4 3 17 9 10 7 211 4 3 11 9 37 3 Bolt Cover 229 43180283 A ir F ilte r S m a ll 212 4 3 11 9 39 3 Shaft Holder 230 43180284 Air Filter Large 213 4 3 11 9 39 4 Lever 231 43A88002 Manual 214 4 3 12 0 17 2 Fan, Sirocco (RAV-162/262CH-PE) 232 43A21008 Geared Motor 214 4 3 12 0 17 4 M u lti B la d e F a n (RAV-362/462CH-PE) 233 43A62001 Cover, Remocon 215 43A21004 F a n M oto r (RAV-162CH-PE) 234 4 3 15 0 14 8 T A S e ns o r 215 43A21005 F a n M oto r (RAV-262CH-PE) 235 43A50002 T C S e ns o r 43102624 S id e C o v e r R ig h t A s m 215 43A21006 F a n M oto r (RAV-362CH-PE) 236 215 43A21007 F a n M oto r (RAV-462CH-PE) 237 43102625 S id e C o v e r L eft A s m 216 4 31 251 31 Bearing 238 4 31 178 12 H Plate 217 4 3 12 5 14 2 Coupling 239 43A58002 T ra n s fo rm e r 218 4 3 12 5 14 3 Shaft SS (RAV-162CH-PE) 240 43A60002 T e rm in a l 3 P 218 4 31 251 41 Shaft SS (RAV-262CH-PE) 241 43A60001 T e rm in a l 4 P 218 4 3 12 5 14 5 Shaft SS (RAV-362CH-PE) 242 43A69002 PC Board 218 4 3 12 5 14 4 Shaft SS 219 4 3 12 6 12 7 F a n Ca s e L o w er (RAV-462CH-PE) 243 43A47004 Asm Distributor (RAV-162CH-PE) (RAV-162/262CH-PE) 243 43047492 Asm Distributor (RAV-262CH-PE) 43A47006 Asm Distributor (RAV-362CH-PE) 219 4 3 12 6 12 9 F a n Ca s e L o w er (RAV-362/462CH-PE) 243 220 4 3 12 6 12 8 Fan Case Upper (RAV-162/262CH-PE) 243 43A47007 Asm Distributor (RAV-462CH-PE) (RAV-362/462CH-PE) 244 43047492 C a p illa ry T u b e 1 .7 D ia (RAV-162CH-PE) 220 4 3 12 6 13 0 Fan Case Upper 221 43139098 Connect Bar 244 43146432 C a p illa ry T u be 2 .2 D ia (RAV-262CH-PE) 222 43A39001 Connect Bar 244 43047527 C a p illa ry T u be 2 .0 D ia (RAV-362/462CH-PE) -80- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.3 Indoor Unit RAV-162KH(W)-PE/RAV-262KH(W)-PE Location No. Part No. 201 43A69004 Remote Controller 203 4 3 12 1 47 4 M o tor Location No. Part No. 2 15 43109364 Grille (RAV-162KH(W)-PE) 2 16 43109280 Grille, Vertical (RAV-262KH(W)-PE) Connection Rod Description Description (RAV-262KH(W)-PE) 203 4 31 214 91 M o tor 2 17 43139098 204 43A69002 PC Board 2 18 43022189 Bearing 205 43A58002 T ra n sfo rm e r, P o w e r 2 19 43196083 Bushing 206 43A60001 T e rm ina l, 4 P 220 4 31 2 01 3 5 F an , C ro s s F lo w (RAV-162KH(W)-PE) 207 4 31 551 01 Capacitor, Electrolytic 220 4 31 2 01 3 6 F an , C ro s s F lo w (RAV-262KH(W)-PE) 208 43A60002 T e rm im a l, 3 P 2 21 4 31 0 93 6 1 G rille , In le t 209 43122028 Nose, Fan Case (RAV-162KH(W)-PE) 222 43109362 G rille , In le t 209 43122029 Nose, Fan Case (RAV-262KH(W)-PE) 223 43180290 Air-Filter 210 4 31 501 18 S e n s o r, R o o m T e m p . 224 43102629 Cabinet, Side, Left 211 4 31 501 16 Sensor, Heat Exch. 225 43102628 Cabinet, Side, Right 212 43144667 Evaporator (RAV-162KH(W)-PE) 226 43063175 Holder, Sensor 212 43144666 Evaporator (RAV-262KH(W)-PE) 227 43019604 Holder, Sensor 213 4 31 721 12 Drain Pan (RAV-162KH(W)-PE) 229 43107234 Holder, Grille 213 4 31 721 14 Drain Pan (RAV-262KH(W)-PE) 230 43A62001 Cover Remocon 214 4 3 17 0 18 2 Hose, Drain 2 31 43A88002 Manual 215 43109363 Grille (RAV-262KH(W)-PE) (RAV-162KH(W)-PE) -81- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.4 Indoor Unit RAV-132UH-PE RAV-162UH-PE RAV-262UH-PE Location No. Part No. Holder, Sensor (TC) 229 4 3 15 0 19 9 S e n s o r (T C ) 4 31 541 41 Relay 230 4 31 512 17 Float Switch 43055275 Capacitor, Electrolytic 233 43A58002 T ra n sfo rm e r, P o w e r 43070146 Hose, Drain 235 4 3 16 0 25 1 Terminal Block 207 43097166 Nut 236 43A60001 T e rm in a l 4 P 221 4 3 12 0 16 6 Radial Fan 237 43A60002 T e rm in a l 3 P 222 4 3 12 1 62 7 Drain, Pump 239 43A62001 Cover, Remocon 223 43 A 21 0 01 M o to r, F a n 240 43A69002 PC Board 225 4 3 13 9 10 3 Rubber, Buffer 241 4 31 721 18 Drain Pan (RAV-132UH-PE) 226 43A44001 Evaporator (RAV-132UH-PE) 4 31 721 17 Drain Pan (RAV-162/262UH-PE) 43144665 Evaporator (RAV-162UH-PE) 242 4 3 17 9 10 4 Drain Filter 43144664 Evaporator (RAV-262UH-PE) 243 4 3 17 9 10 5 Plug 43146432 Capillary Tube (RAV-132UH-PE) 245 43A88002 Manual 43047527 Capillary Tube (RAV-162UH-PE) 249 4 3 10 7 21 2 Bolt 43047492 Capillary Tube (RAV-262UH-PE) 250 4 3 13 9 10 5 Washer 4 31 501 18 S e n s o r (T A ) 251 43A69004 Remote Controller 252 43033084 Location No. Part No. 202 43019604 204 205 206 227 228 Description Description Spark-killer -82- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.5 Indoor Unit RAV-362UH-PE RAV-462UH-PE Location No. Part No. Location No. 2 01 43A69004 Remote Controller 235 4 3 15 1 20 3 Float Switch 202 43A62001 Cover, Remocon 237 43055292 Capacitor, Electrolytic (RAV-362UH-PE) 203 43019604 Holder, Sensor 237 43155080 Capacitor, Electrolytic (RAV-462UH-PE) 204 43 15 4141 Relay 239 43A58002 T ra n sfo rm e r, P o w e r 205 43070146 Hose, Drain 240 43A60001 T e rm ina l, 4 P 2 18 4 31 2 01 6 4 Fan, Multi-blade 241 43A60002 T e rm ina l, 3 P 2 19 43 A 21 0 10 M o to r, F a n 244 4 3 17 0 19 2 Hose, Drain 222 4 31 2 16 2 7 D ra in, P u m p 246 4 31 721 16 Drain Pan 223 4 31 2 61 2 5 F an C a s e Lo w e r 247 4 3 17 9 10 4 Drain Filter 224 4 31 2 61 2 6 Fan Case Upper 248 4 3 17 9 10 5 Plug 225 4 31 4 46 6 1 Evaporator, Right (RAV-362UH-PE) 250 43A88002 Manual 225 43144660 Evaporator, Right (RAV-462UH-PE) 252 43A69002 PC Board 226 43144663 Evaporator, Left (RAV-362UH-PE) 253 43033084 226 43144662 Evaporator, Left (RAV-462UH-PE) 2 31 43047527 C a p illa ry T u b e 2 .0 D IA 233 43150 111 Sensor 234 4 31 5 01 4 8 Sensor Description Part No. Description Spark-killer -83- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.6 Ceiling panel RBC-U262PG(W)-PE RBC-U462PG(W)-PE Location No. Part No. 202 43407009 206 43407024 207 43407014 Slider 208 43407015 Lever 209 37507500 Lever 210 43409063 Intake-Grill Assy (RBC-U262PG(W)-PE) 43409059 Intake-Grill Assy (RBC-U462PG(W)-PE) 43409067 Holder. Shaft 211 Location No. Part No. Grille, Catch 214 43121550 Cam 215 43480533 Air-Filter (RBC-U262PG(W)-PE) 43480531 Air-Filter (RBC-U462PG(W)-PE) 43409070 Grille, Outlet (RBC-U262PG(W)-PE) 43409069 Grille, Outlet (RBC-U462PG(W)-PE) 220 43409075 Grille, Outlet, Small 227 43497009 Spring Holder Description 217 Description Geared-Motor (RBC-U462PG(W)-PE) -84- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements 15.7 Outdoor unit RAV-162AH-PE Location No. 1 Fan, Propeller Location No. 23 2 43A21003 Motor, Fan, AC230V, 50Hz 24 43155080 Capacitor, Electrolytic 3 43A43001 Condenser 25 4 43149212 Base, Spring, A 5 43049132 Spring, Buffer 26 43041845 Compressor, AC220/240V, 50Hz, PH250X3-4LS 43146454 Packed Valve (1/4") 6 43049132 Base, Spring, B 27 43146406 Packed Valve (1/2") 7 Part No. 43120156 Description 43A69003 PC Board 8 43A49001 Switch, High-Pressure 9 43060479 Terminal, 4P 10 11 43A60003 Terminal, 2P 43A60001 Terminal, 4P 12 43152334 13 43054286 Relay, Overload 14 43A19001 15 Magnetic Contactor Guard, Fan 43119368 Hanger 16 43A46004 Solenoid Coil 17 43162027 Cover, Electric Parts 18 43155115 Capacitor, Plastic Film, 45MFD, 440V 20 43107215 Holder, Sensor (TE) 21 43169600 Holder 22 43148105 Accumulator Part No. Description 43145082 Dryer 28 43147321 29 43146424 Expansion Valve Check Joint 30 43046198 Coil, 2-Way Valve 31 43146283 Checked Valve 33 43A58003 Transforrmer, Power 34 43046151 35 43193043 Spring Valve, 2-Way 36 43A50001 Sensor, Cond. Out (TL) 37 43150196 38 43146418 Valve 4-Way 39 43157167 Heater, Crankcase Sensor, Heat Exch. (TE) 41 43146459 Capillary Tube 42 44246235 Capillary Tube 43 43150122 Thermostat, Bimetal 44 43107215 Holder, Sensor (TL) -85- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements RAV-262AH-PE Location No. Part No. Location No. Description Part No. Description 1 43120156 Fan, Propeller 23 43145082 Dryer 2 43A21002 Motor, Fan, AC 230V, 50Hz 24 43155080 Capacitor,Plastic Film 3 43A43002 Condenser 25 43140318 Compressor, PH330X3-4MS 4 43049132 Base, Spring, B 26 43146451 Packed Valve (3/8") 5 43149198 Spring, Buffer 27 43146417 Packed Valve (5/8") 6 43149212 Base, Spring, A 28 43147321 Check Joint 7 43A69003 PC Board 29 43146433 Expansion Valve 8 43A49001 Switch, High-Pressure 30 43046156 Checked Valve 9 43060479 Terminal, 4P 31 43146283 Checked Valve 10 43A60004 Terminal, 2P 33 43A58003 Transforrmer, Power 11 43A60001 Terminal, 4P 34 43046151 Valve, 2-Way 12 43152334 Magnetic Contactor 35 43046198 Coil, 2-Way Valve 13 43150122 36 43A50001 Sensor, Cond. Out (TL) 14 43A19001 Guard, Fan 37 43150196 15 43119368 38 43193043 Spring 16 43A46004 Solenoid Coil 39 43157167 17 43162027 Cover, Electric Parts 40 44246236 Capillary Tube Thermostat, Bimetal Hanger Sensor, Heat Exch. (TE) Heater, Crankcase 18 43146418 Valve, 4-Way 41 43055379 Capillary, Electrolytic 20 43107215 Holder, Sensor (TE) 43 43146459 21 43169600 Holder 44 43107215 Holder, Sensor (TL) 22 43148114 Capillary Tube Accumulator -86- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements RAV-262AH8-PE Location No. Part No. Location No. Description Part No. Description 1 43120156 Fan, Propeller 22 43148114 2 43A21002 Motor, Fan, AC 230V, 50Hz 23 43145082 Dryer 3 43A43002 Condenser 24 43155080 Capacitor, Plastic Film 4 43049132 Base, Spring, B 25 43141302 5 43149198 Spring, Buffer Compressor, AC 380/415V, 50Hz, YH330X3-MS 6 43149212 Base, Spring, A 26 43146451 Packed Valve (3/8") 7 43A69003 PC Board 27 43146417 Packed Valve (5/8") 8 43A49001 Switch, High-Pressure 28 43147321 Check Joint 9 43060479 Terminal, 4P 29 43146433 Expansion Valve 10 43A60005 Terminal, 4P 30 43046156 Checked Valve 11 43A60001 Terminal, 4P 31 43146283 Checked Valve 12 43152345 Magnetic Contactor 33 43A58003 Transforrmer, Power 13 43050277 Thermostat, Bimetal 34 43154148 14 43A19001 36 43A50001 Sensor, Cond. Out (TL) Guard, Fan Accumulator Return Lock STR-4AB 15 43119368 Hanger 37 43150196 16 43A46004 Solenoid Coil 38 43193043 Spring Sensor, Heat Exch. (TE) 17 43162027 Cover, Electric Parts 39 43157167 18 43146418 Valve, 4-Way 41 43063195 Holder Thermostat, Bimetal Heater, Crankcase 20 43107215 Holder, Sensor (For TE) 43 43146459 Capillary Tube 21 43169600 Holder 44 43107215 Holder, Sensor (TL) -87- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements RAV-362AH8-PE RAV-462AH8-PE Location No. 1 2 3 4 5 5 6 6 7 7 8 9 10 10 11 12 13 14 14 15 16 17 18 18 Part No. 43A21002 43A21003 43120156 43A19001 43143638 43143636 43143639 43143637 43047492 43047527 43119368 43162027 43140404 43140506 43149198 43149212 43049132 43146362 43146438 43146451 43146416 43147321 43146498 43146499 Location No. 19 20 21 21 22 23 24 25 26 27 27 28 29 30 32 33 34 35 36 37 37 38 39 Description Motor, AC 230V, 50Hz, Fan Motor, AC 230V, 50Hz, Fan Fan, Propeller Guard, Fan Condenser, Lower Condenser, Lower Condenser, Upper Condenser, Upper Capillary Tube Capillary Tube Hanger Cover, Electric Parts Compressor, YH406JA Compressor, YH506JA Spring, Buffer Base, Spring, A Base, Spring, B Expansion Valve Expansion Valve Packed Valve (3/8") Packed Valve (3/4") Check Joint Valve, 4-Way Valve, 4-Way (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) Part No. 43146283 43145092 43148096 43148114 43155080 43060479 43A60005 43A60001 43107215 43152342 43152343 43150196 43A50001 43A69003 43A46004 43169600 43163016 43A49001 43157140 43146430 43146431 43107215 43A58003 Description Checked Valve Dryer Accumulator Accumulator Capacitor, Plastic Film Terminal, 4P Terminal, 4P Terminal, 4P Holder, Sensor (TL) Magnetic Contactor Magnetic Contactor Sensor, Heat Exch. (TE) Sensor, Cond. OUt (TL) PC Board Solenoid Coil Holder Support Switch, High-Pressure Heater, Crankcase Capillary Tube Capillary Tube Holder, Sensor (TE) Transformer, Power (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) (RAV-362AH8-PE) (RAV-462AH8-PE) -88- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807 Heronhill - for all your Toshiba requirements -89- Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807