Transcript
MOD Bus (RS485) Common Speed Sensing (Max 50VAC) J1939 and RS485 require 120Ω impedance shielded A Speed Input is used with 120Ω 120Ω twisted pair cable. magnetic pickups, flywheel Generator B Example: Belden 7895A alternator, or tachometer. CAN Bus (J1939) Example: Belden 9841 NOT required for generators Shield or electronic engines. High 120Ω 120Ω Low +BAT Max 575VAC Emergency Stop A )+( +Battery Ground )-( 10 9 8 7 6 J6 5 4 3 2 1 Review user manual for 1 more detailed information 2 B C on wiring and controller 3 Battery (5.5-36V) J4 N configuration. 4 8 9 10 11 12 13 14 Fuel +BAT 1 2 3 4 5 6 7 J7 A Switch Input B B C N Switch Input C Max 5A Switch Input D Switch Input E A 1 Switch Output D Sensor Input B (0 - 750Ω) +BAT Sensor Input C (Universal) Sensor Input A (0 - 7,500Ω) B Crank Switch Output E J1 2 C J3 3 1 2 3 4 5 6 7 8 CT COMMON 4 USB Connection J5 If current readings are unstable with this configuration, attempt connecting the CT Glow Common's to the negative terminal of the battery. Load Switch Output F Sensor Input D (Universal) Ensure the connecting wire is as short as possible. +BAT Start / Stop Contacts Switched Inputs can be configured to detect Engine Temperature Oil Pressure Fuel Level DC Load (Max 1A) Sensor DC Load DC Load Input (Max 1A) (Max 1A) battery, ground, or open. Main Connector J4-1 +Battery J4-2 +Battery J4-3 Ground J4-4 Ground J4-5 Switch Input A J4-6 Switch Input B J4-7 Switch Input C J3-1 J4-8 Switch Output A J4-9 Communication Connector Generator Connector (A) J6-1 RS485-A J5-1 Gen. Current (A) J6-2 RS485-B J5-2 Gen. Current (B) Switch Input D J6-3 Reserved J5-3 Gen. Current (C) J3-2 Switch Input E J6-4 CAN High J5-4 CT Common Switch Output C J3-3 Switch Output D J6-5 CAN Low J4-10 Switch Output B J3-4 Switch Output E J6-6 CAN Ground Generator Connector (V) J4-11 Sensor Ground J3-5 Switch Output F J6-7 Speed Input J7-1 Gen. Phase A Project Name Wiring Diagrams J4-12 Sensor Input A J3-6 Sensor Power (5V) J6-8 Speed Reference J7-2 Gen. Phase B Drawing Name TG410 Example Drawing Number DWG1501 J4-13 Sensor Input B J3-7 Sensor Ground J6-9 Reserved J7-3 Gen. Phase C DRAWING NOTES Expansion Connector NOTE 1: NOTE 2: NOTE 3: NOTE 4: NOTE 5: NOTE 6: J4-14 Sensor Input C J3-8 Sensor Input D J6-10 RS485 Ground J7-4 Neutral NOTE 7: Your application and wiring may vary. Refer to full user manual for detailed information on using your controller www.dynagen.ca/support. NOTE 8: THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION AND/OR TRADE SECRETS WHICH ARE THE PROPERTY OF DYNAGEN TECHNOLOGIES INC. THIS DOCUMENT MAY NOT BE REPRODUCED OR TRANSMITTED TO OTHERS IN ANY MANNER, NOR MAY ANY USE OF THE INFORMATION ON THIS DOCUMENT BE MADE, EXCEPT FOR THE SPECIFIC PURPOSES FOR WHICH IT IS TRANSMITTED TO THE RECIPIENT, WITHOUT THE PRIOR WRITTEN CONSENT OF DYNAGEN TECHNOLOGIES INC. Drawing Revision 1.4.0 Drawing Scale Not To Scale Drawing Size ANSI-B / Ledger Created On 12/19/2012 Modified On 01/13/2014 Created By Everett Pattison Modified By Everett Pattison