Download USER MANUAL FOR EXPLOSION PROTECTED LOW
Transcript
d.o.o. 10090 Zagreb, Medarska 69 tel. 049 222900, fax 049 426450 e-mail: [email protected] USER MANUAL FOR EXPLOSION PROTECTED LOW VOLTAGE SWITCHGEAR AND CONTROL GEAR ASSEMBLYES type SKX 16/.., SKX 18/.., SKX20/.. No: TEPEx.RS.030 Rev : 1 Date: 06.2014 MANUFACTURER TEP Ex d.o.o. , Medarska 69, HR-10090 Zagreb tel. 049/222-900, fax 049/426-450, e-mail: tepextepex.hr, www.tepex.hr PURPOSE Explosion protected control units type SKX 16 – SKX 20, independently or in combination coupled record (combination), are intended for the management, distribution and signaling in the power circles:: in hazardous areas due to the presence of flammable and explosive gases, vapors or mists in Zones 1 and 2 in hazardous areas due to the presence of flammable and explosive dust in Zones 21, 22 TYPE OF PROTECTION The explosion protection ensure utilizing types of protection: - EN 60079-0:2012, EN 60079-1:2007, EN 60079-7:2007, EN 60079-11:2012, EN 60079-18:2009, EN 60079-31:2009. Apparatus category and marking of explosion-protection: Certificate: Marking: EXA 14 ATEX 029 2465 II 2G Ex d e mb ia/ib IIC T4 - T6 Gb II 2D Ex tb IIIC T80C Db Apparatus category and marking of explosion-protection: Ambient temperature: -20ºC ≤ Ta ≤ +50ºC Degree of protection: IP 66 Resistance to shock: IK 08 CONSTRUCTION In and on Ex e enclosure or combination of multiple enclosures, interconnected by bushing, are mounted " Ex e d m ia/ib" and Ex e built-in components and actuator and indicators. There are no limitation in orientation of encosure/combination of multiple enclosures, (longer side of enclosure is mounted horizontally or vertically) and the manner of which the mounting is set to the surface. In horizontal orientation of enclosure, built-in components and actuator and indicators are mounted in maximum two rows. In vertical orientation of enclosure , built-in components and actuator and indicators are mounted in maximum: - SKX 16 - 2 rows - SKX 18 - 3 rows - SKX 20 - 5 rows The actual nuber of mounted rows depends on the device configuration. Circuit breaker 3p/4p Ith = 40 A, 80 A with its matching actuatuator or block NH 00 main fuse always occupies two hole rows, Actuator and indicators – circuit breaker which are not connected with the actuaror, always occupie one and a half row. In one row there can be maximaly be: - SKX 16 - 6 pols, horizontal and vertical orientation of the enclosure, - SKX 18 - 12 pols vertical, 8 pols horizontal orientation of the enclosure, - SKX 20 - 18 pols vertical, 12 pols horizontal orientation of the enclosure. Permitted installation and current loading of terminals is determined with table of maximum losses of terminal boxes SKX16/E. Table is expanded with 50 mm2 and 70 mm2 terminals, and same data is valid as for 35 mm2 terminals. Possible combinations, number and distribution of actuators and indicators and built-in components are determined by certification drawings. 1 A B 80 SKX 20 SKX 18 A C C 110 110 D A 110 110 SKX 18 2,3 250 250 502 ±0.5 400 2,3 B D K 110 1260 600 SKX 20 110 2,3 D SKX 16 C 80 255 SKX 16 B Built-in components are installed in enclosures with screw fitting connection to steel base plate 2 mm, in such way that they provide clearance according to standards (creepage distances are determined by component construction) minimum 12 mm of clearance between Ex e terminals and minimum 50 mm between Ex e and EX i terminals. Control units, generally, are not factory-wired. When they are shipped wired, wiring is done with H07V-K type cables with appropriate cross-section with lug fastons. Distribution of intrinsic safe and non- intrinsic safe wiring is done separately, without mutual crossings. Certified Ex e cable glands, chosen according to cable type are used for cable entries. If metal cable glands are used, an external earthing terminal is mounted next to them. Unused cable entries are closed with EX e plugs. For intrinsic safe circuits blue (RAL 5012) terminals are used. For cable entry of intrinsic safe circuits into enclosure cable glands with blue cable glands nut is used. Device is designed in accordance with EN 60493-1:1991.+A1:2004, EN 60947-7-1,2,3:2002, and all other connected standards. Example of design SKX combination 2 TECHNICAL DATA Rated insulation voltage Ui : Nominal current Ith : PE terminals (inside the enclosure): Cover screw: Cable glands: Surface resistance: Energy shock: Colour: Dimensions LxWxH (without cable glands): Mounting dimensions: 690 V AC (terminal type SL.. Ui=400V AC) up to 80A max. 2x4 mm2+2x2,5 mm2 , 3x4 mm2 , 2x6 mm2 – solid, stranded, flexible Screw M6x30 (Z4) - 4.8 A2 Tightening torque 1,5 Nm Tightening torque of cable gland nut and body, depending on the size, according to the manufacturer's instructions < 109 Ω 7J Black , RAL 9005 SKX 16: 255x250x120/160 mm SKX 18: 400x250x120/160 mm SKX 20: 600x250x120/160 mm With screw through hole 12/7mm SKX 16: 235 x 200 mm SKX 18: 380 x 200 mm SKX 20: 580 x 200 mm Dimension drawings for moulded plastic enclosures (without cable glands ): 255 120 162 SKX 16/ 250 3 162 400 120 SKX 18/ 250 600 120 162 SKX 20/ 250 4 ACTUATORS AND INDICATOR ELEMENTS: TYPE DESCRIPTION MOUNTING DIMENSION 42 90 70 0 OTVOR U STIJNCI POKLOPCA SWITCH ACTUATOR 5 23 SMO 17/. - manufacturer: TEP Ex d.o.o. - explosion protection: I M2 II 2GD Ex e I/II IP66 - certificate: HREx T 06.025U ,2 ±0 I I 0 II 0 I III 32±0,5 SMO 17/1 SMO 17/2 0 1 SMO 17/3 1 2 I III 3 SMO 17/6 SMO 17/4 1 2 II SMO 17/5 2 3 3 4 4 SMO 17/7 5 SMO 17/8 1 2 5 4 3 6 SMO 17/9 64,5±0,1 76 - manufacturer: TEP Ex d.o.o. - explosion protection: II 2GD Ex e II IP66 - certificate: HREx T 06.026U 56 -0,2 +0,5 12 FRONT ELEMENT OF MEASURING INSTRUMENTS SAM 72 II I II 3,5 76 34 38 PUSCHBUTTON ACTUATOR 2,8 +0,2 0 Type SPO 01/. 0 16 +0,2 SPO 01/. - manufacturer: TEP Ex d.o.o. - explosion protection: - II 2GD EEx e II T80°C IP66 - certificate: HREx T 04.020U SPO 01/01 SPO 01/02 30 +0,2 0 SPO 01/03 SPO 01/04 SPO 01/05 SPO 01/06 SPO 01/07 SPO 01/08 SPO 01/09 SPO 01/10 0 I II red green white START STOP ON OFF 38 0 16 +0,2 SPO 02/. 20 2,8 +0,2 0 - manufacturer: TEP Ex d.o.o. - explosion protection: II 2GD EEx e II T80°C IP66 - certificate: HREx T 04.020U 38 18 FRONT ELEMENT OF SIGNAL LAMP Type SPO 02/. 30 +0,2 0 SPO 02/01 RED TRANSP. SPO 02/02 GREEN TRANSP. SPO 02/03 YELLOW TRANSP. SPO 02/04 KEY-OPERATED PUSHBUTTON ACTUATOR 56 21 2,8 +0,2 0 0 16 +0,2 GHG 410 1904 R0012 - manufacturer: CEAG GmbH - explosion protection: certificirano unutar GHG 41...R... II 2G/D EEx e II IP66 - certificate: PBT 00 ATEX 3117 TRANSPARENT 30 +0,2 0 5 MUSHROOM-HEAD PUSHBUTTON ACTUATOR (EMERGENCY-STOP) GHG 410 1905 R0006 - manufacturer: CEAG GmbH - explosion protection: II 2G/D EEx e II IP66 - certificate: PBT 00 ATEX 3117 KEY-OPERATED MUSHROOM-HEAD PUSHBUTTON ACTUATOR (EMERGENCY-STOP) O38 0 16 +0,2 2,8 30 +0,2 0 21 2,8 +0,2 0 0 16 +0,2 GHG 410 1905 R0005 21 +0,2 0 - manufacturer: CEAG GmbH - explosion protection: II 2G/D EEx e II IP66 - certificate: PBT 00 ATEX 3117 SWITCH ACTUATOR 30 +0,2 0 56 30 21 2,8 +0,2 0 - manufacturer: CEAG GmbH - explosion protection: II 2G/D EEx e II IP66 - certificate: PBT 00 ATEX 3117 CABLE GLAND 30 +0,2 0 30 0 16 +0,2 GHG 410 1944 R0010 33 +0,2 - manufacturer: TEP Ex d.o.o. - explosion protection: II 2GD EEx e II IP66 - certificate: HREx T 00.005X M25x1.5 SPU 25 (M25) 25,5 -0,4 44 CABLE GLAND GHG 960 1955 - manufacturer: CEAG GmbH - explosion protection: II 2GD EEx e II IP66 - certificate: PBT 99 ATEX 3101X, PTB 99 ATEX 3128X A,5 A,5 +0,2 -0,4 +0,2 -0,4 A A A = M16-M40 CABLE GLAND - manufacturer: ELFIT S.p.A - explosion protection: II 2GD EEx d IIC Eex e II IP66/67 - certificate: CESI 02 ATEX 081 X SPC 25 M25 GHG 960 A,5 A A = M16-M40 OK30 +0,2 A 25,5 -0,4 - manufacturer: TEP Ex d.o.o. - explosion protection: II 2GD EEx e II IP66 - certificate: HREx T 04.009 PLUG - manufacturer: CEAG GmbH - explosion protection: II 2GD EEx e II IP66 - certificate: PBT 99 ATEX 3130 +0,2 -0,4 3 PLUG A,5 +0,2 -0,4 18 FGA1 – FGA4 M25x1.5 A A,5 +0,2 -0,4 A A,5 +0,2 -0,4 A = M16-M40 6 BUILD-IN COMPONENTS: TYPE DESCRIPTION + technical data WIRING DIAGRAM DIMENSION SMS 03/1 SMS 03/4 SMS 03/5 SMS 03/6 SMS 03/. - 80 35 manufacturer: TEP Ex d.o.o. explosion protection: I M2 Ex de I II 2G Ex de IIC rated voltage: 660V rated current: 16A rated section: 2,5mm2 certificate: HREx T 01.016U SMS 03/3 SMS 03/2 70 - SMS 03/12 5 CONTROL SWITCH 4 72 SMS 03/7 80 SMS 03/10 SMS 03/8 SMS 03/9 SMS 03/11 060 062 CONTROL SWITCH 48 72 065 061 063 50 GHG 23. GHG 29. manufacturer: CEAG GmbH explosion protection: II 2G Ex de IIC - rated voltage: 690V - rated current: 10/20A - rated section: 2,5/6 mm2 - certificate: GHG 23. - PTB 98 ATEX 1116U GHG 29. - PTB 98 ATEX 1118U 4,5 - 4 067 62 70 011 034 7 037 049 023 019 033 024 SLP - manufacturer: TEP Ex d.o.o. explosion protection: I M2 Ex de I II 2GD Ex de IIC rated voltage: 20-250V AC/DC Imax: 20mA rated section: 2,5mm2 certificate: HREx T 06.027U 45 21 13 23 11 21 14 22 14 24 12 22 PBT/02 PBT/03 34 PBT/01 62 68 80 - 13 45 PBT/. manufacturer: TEP Ex d.o.o. explosion protection: I M2 Ex de I II 2GD Ex de IIC T6 - rated voltage: 690V - rated current: 16A - rated section: 2,5mm2 - certificate: HREx T 06.028U SIGNAL LAMPS X1 X2 34 - 12 PUSHBUTTON 62 68 POTENTIONMETER 56 32 66 90 AM 45/72, VM 45/72 - manufacturer: CEAG GmbH - explosion protection: II 2G EEx em IIC EEx ib Iic - measuring range: AM: n/1A 0-20mA 0-25A direct 4-20mA VM: n/1A 6-415V 6-660V - scale: 0-600A, 20 tipova - connection terminal: 1,54mm2 - certificate: PBT 99 ATEX 2032U 52 58 70 GHG 41. manufacturer: CEAG GmbH explosion protection: II 2G Ex de IIC - rated voltage: 250V - resistance range: 100-10 000Ω - scale: 0-100% - connection terminal: 2,5mm2 - certificate: PBT 97 ATEX1081U MEASURING INSTRUMENTS 70 - 8 SL 5 - 10 manufacturer: TEP Ex d.o.o. explosion protection: I M2 Ex e I II 2GD Ex e IIC rated voltage: 400V connection terminal: 4mm2 certificate: HREx T 05.002U 19 26 - 50 MANTLE TERMINALS 57 96 SL 8 - manufacturer: TEP Ex d.o.o. explosion protection: I M2 Ex e I II 2GD Ex e IIC rated voltage: 400V connection terminal: 4mm2 certificate: HREx T 05.002U 60 - 16 MANTLE TERMINALS 44 84 TERMINALS EURO 4/35 EURO 1625/35 5 terminals 4 mm2 with rail 357,5 TH - manufacturer: MORSETTITALIA - explosion protection: II 2GD EEx e II - certificate: KEMA 03ATEX2118 U - 2 terminals 16 mm2 with rail TH 35-7,5 - manufacturer:MORSETTITA LIA - explosion protection: II 2GD EEx e II - certificate: KEMA 03ATEX2118 U NH 00 MAIN FUSE type: NH0 300XX, NH0 301XX - manufacturer: CEAG GmbH - explosion protection: II2G Ex de IIC - certificate: PTB 99 ATEX 1066U HSC 300 40 HSC 300 80 HSC 400 40 HSC 400 80 MAIN CURRENT SWITCH type: HSC ... .. - manufacturer: CEAG GmbH - explosion protection: II2G Ex de IIC certificate: PTB 99 ATEX 1031U 9 MAINTANCE, REPAIR AND OVERHAUL Maintenance is performed in accordance with EN 60079-17:2007, the national rules and user policy. Repair and overhaul is performed in accordance with EN 60079-19:2007 and applicable national rules. Repairs that affect the explosion protection, may only be carried out by TEP Ex or a qualified electrician in compliance with the national rules. Modifications to the control unuts or changes of its design are not permitted. Every improper usage, as well as every unofficial repair or modification of the product, release the manufacturer of all responsibilities.. MARKING Explosion protected control units, types SKX 12 - SKX 15, are labeled with: - marking labels HR-10090 1) SKX ../... Ui = ...2) V 2465 Zagreb Ith = ...2) A IP66 II 2G Ex d e ia/ib mb IIC T4 - T6 Gb 3) II 2D Ex tb IIIC T80°C Db EXA 14 ATEX . . . 4). - MA/MR ....5) DAT....6) warning label: WARNING DO NOT OPEN WHEN ENERGIZED 94,5 42 RESPONSIBILITY AND AUTHORIZATION Responsibility and authorization are defined by the "Regulation on technical supervision over the electrical stations, installations and equipment intended for usage in potentially explosive atmospheres" . This Manual represents the most relevant information about the product. Adequate national laws and regulations supplement it. TheZagreb person in charge 0722 is required to secure its employment in the HR - 10090 industrial unit. Every improper usage, as well SKX as every repair or restoration of the product, release the . ./ . . unofficial .1) . . . V2)restructuring, . . . A3) IP66 manufacturer of all responsibilities. II 2G Ex de IIC T6 Gb II 2D Ex t IIIC T80°C Db 6) CESI 12 ATEX ... 4) MA/MR .......5) DATE ...... STORAGE AND TRANSPORT Transport and storage is only allowed in the original packaging, on the way pointed out on the carton box. Control units with measuring instruments type AM72, VM72 OR All rights reserved. II 2G II 2D Ex de mb IIC T6 Gb Ex t IIIC T80°C Db Control units with terminals type SL5, SL8, TH 35 5x4mm2 II 2G Ex e II T6 Gb II 2D Ex t IIIC T80°C Db Control units with Ex i terminals 5x4mm2 II 2G Ex ia/ib IIC T6 Ga/Gb 06.2014. / Rev. 01 10