Download User Manual

Transcript
User Manual
Unicorn 60X0
Analog IP Gateway
4 or 8 FXO Ports
Hanlong Technology Co., Ltd
http://www.hanlongtek.com
Table of Content
1
WELCOME ................................................................................................................ 3
1.1
Gateway Unicorn 60x0 Overview .................................................................. 3
1.2
Safety Compliances....................................................................................... 3
1.3
Warranty ........................................................................................................ 4
2
PACKAGING ............................................................................................................. 4
2.1
Connect The Unicorn 60x0 ............................................................................ 4
3
APPLICATION DESCRIPTION ................................................................................. 6
3.1
Functional Diagram of IP-PBX & Unicorn 60x0 ............................................. 6
3.2
Unicorn 600x&Unicorn 60x0 Scenario/Toll- Free Calling Between Locations 7
4
FEATURES................................................................................................................ 7
4.1
Software Features Overview ......................................................................... 7
4.2
Hardware Specification.................................................................................. 9
5
CONFIGURATION GUIDE......................................................................................... 9
5.1
Configuration With Web Browser................................................................... 9
5.1.1
Accessing The Web Configuration Menu.............................................. 9
5.2
End User Configuration ............................................................................... 10
5.2.1
Status Page Definitions .......................................................................11
5.2.2
Basic Settings Page ............................................................................11
5.3
Super User Settings .................................................................................... 12
5.3.1
Super Configuration Page Definitions................................................. 13
5.3.2
Profiles ............................................................................................... 14
5.3.3
Configuring The FXO Channels.......................................................... 21
5.4
Saving The Configuration Changes............................................................. 22
5.5
Rebooting From Remote ............................................................................. 23
6
7
8
FIRMWARE UPGRADE........................................................................................... 23
RESTORE FACTORY DEFAULT SETTINGS.......................................................... 24
TECHNICAL SUPPORT CONTACT........................................................................ 25
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 2 of 25
Last Updated 8/2010
1 WELCOME
Thank you for purchasing the Hanlong Unicorn 60x0 IP Analog FXO Gateway. The
Unicorn 60x0 is a cost effective, easy to use and easy to configure IP communications
solution for any business. The Unicorn 60x0 supports popular voice Codecs and is
designed for full SIP compatibility and interoperability with 3rd party SIP providers, thus
enabling you to fully leverage the benefits of VoIP technology, integrate a traditional phone
system into a VoIP network, and efficiently manages communication costs.
This manual will help you learn how to operate and manage your Unicorn 60x0 Analog IP
Gateway and make the best use of its many upgraded features including simple and quick
installation, multi-party conferencing, etc. This IP Analog Gateway is very easy to manage
and scalable, specifically designed to be an easy to use and affordable VoIP solution for
the small – medium business or enterprise.
1.1
Gateway Unicorn 60x0 Overview
The Unicorn 60x0 offers an easy to manage, feature rich IP communications solution for
any small business or businesses with virtual and/or branch locations who want to
leverage their broadband network and/or add new IP Technology to their current phone
system. The Hanlong Enterprise Analog VoIP Gateway Unicorn 60x0 series converts
SIP/RTP IP calls to traditional PSTN calls and vice versa. There are two models - the
Unicorn 6040 and Unicorn 6080, which have either 4 or 8 FXO ports respectively. The
installation is the same for either model.
Caution: Changes or modifications to this product not expressly approved by Hanlong
Technology, or operation of this product in any way other than as detailed by this User
Manual, could void your manufacturer warranty.
Information in this document is subject to change without notice. No part of this document
may be reproduced or transmitted in any form or by any means, electronic or mechanical,
for any purpose without the express written permission of Hanlong Technology.
1.2
Safety Compliances
The Unicorn 60x0 is compliant with various safety standards including FCC/CE. Its power
adaptor is compliant with UL standard.
Warning: use only the power adapter included in the Unicorn 60x0 package. Using an
alternative power adapter may permanently damage the unit.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 3 of 25
Last Updated 8/2010
1.3
Warranty
Hanlong has a reseller agreement with our reseller customer. End users should contact
the company from whom you purchased the product for replacement, repair or refund.
If you purchased the product directly from Hanlong, contact your Hanlong Sales and
Service Representative for a RMA (Return Materials Authorization) number. Hanlong
reserves the right to remedy warranty policy without prior notification.
2 PACKAGING
Unpack and check all accessories. The Unicorn 60x0 package contains:

One Unicorn 60x0 VoIP adapter

One universal power supply

One Ethernet cable
2.1
Connect The Unicorn 60x0
Managing the Unicorn 60x0 gateway and connecting the unit to the VoIP network is very
simple. Follow these four (4) steps to connect your Unicorn 60x0 gateway to the Internet
and access the unit’s configuration pages.
1. Connect PSTN Line to the FXO1-FXO8 ports.
2. Insert the Ethernet cable into the WAN port of Unicorn 60x0 and connect the other end
of the Ethernet cable to an uplink port (a router or a modem, etc.)
3. Connect a PC to the LAN port of Unicorn 60x0 for initial configuration or if it is being
used as a router.
4. Plug the power adapter into the Unicorn 60x0 and into a power outlet.
Figure 1:
Diagram of Unicorn 60x0 Back Panel
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 4 of 25
Last Updated 8/2010
TABLE 1:
Definitions Of The Unicorn Connectors
LAN (or PC)
Connect your PC to this port. It will then be assigned an
IP address from your Router/DHCP Server. The
Unicorn 60x0 acts as a switch only.
WAN (or LAN)
Connect to the internal LAN network or Public Internet.
RESET
Factory Reset button. Press for 7 seconds to reset
factory default settings.
POWER IN
Power adapter connection
FXO1 - FXO8
FXO ports to be connected to physical PSTN lines from
a traditional PSTN PBX or PSTN Central Office.
Figure 2:
Diagram Of Unicorn 60x0 Display Panel
TABLE 2:
Definitions Of The Unicorn Display Panel
Power LED
Indicates Power.
Remains ON when Power is connected and turned ON.
Ready LED
Remains ON after boot-up.
LAN LED
Indicates LAN (or WAN) port activity
WAN LED
Indicates PC (or LAN) port activity
LEDs 1 - 8
Indicate status of the respective FXO Ports on the back
panel
Busy - ON
Available - OFF.
NOTE:
All LEDs display green when ON.
During a firmware upgrade or configuration download the following LED pattern will be
observed:
Power, WAN LEDs will be ON. The RUN LED will keep flashing during download and
while the new files are written. The entire process may take between 5 to 15 minutes. The
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 5 of 25
Last Updated 8/2010
firmware upgrade is complete when you can login into the web configuration pages.
3 APPLICATION DESCRIPTION
3.1
Functional Diagram of IP-PBX & Unicorn 60x0
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 6 of 25
Last Updated 8/2010
3.2
Unicorn 600x&Unicorn 60x0 Scenario/TollFree Calling Between Locations
4 FEATURES
Unicorn 60x0 is a next generation IP voice and video gateway that features full
interoperability with leading IP-PBXs, SoftSwitches and SIP platforms. The Gateway
series offers superb voice and video quality, traditional telephony functionality, simple
configuration, feature rich functionality and an additional video port that enables the
gateway to act like a video surveillance gateway.
4.1


Software Features Overview
4 and 8 FXO port gateways
External power supply
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 7 of 25
Last Updated 8/2010








Two RJ-45 ports (switched or routed)
TFTP and HTTP firmware upgrade support
Multiple SIP accounts, multiple SIP profiles (choice of 2 profiles per account)
Supports Audio Codecs: G711U/A, G723, G729A/B and GSM
G.168 – echo cancellation
Flexible DTMF transmission: In Audio, RFC2833, SIP Info or any combination of the 3
Selectable, multiple LBR coders per channel
T.38 compliant
TABLE 3:
Unicorn 60x0 Software Features
Unicorn 60x0 FXO Analog Gateway Series
IP settings
Telephone Interfaces
Network Interface
LED Indicators
Voice over Packet
Capabilities
Voice Compression
DHCP Server/Client
Fax over IP
QoS
IP Transport
PSTN Signaling
DTMF Method
IP Signaling
Provisioning
Control
Management
Short and long haul
Unicorn 6040:
4 ports; 4 SIP accounts w/ choice of 3 SIP Server profiles
Unicorn 6080:
8 ports; 8 SIP accounts w/ choice of 3 SIP Server profiles
Round-robin port scheduling to ensure available lines to
access PSTN networks
4 or 8 FXO, RJ11
Two (2) 10M/100 Mbps, RJ-45
Power and Line LEDs
G.168 compliant Echo Cancellation, Dynamic Jitter
Buffer, Modem detection & auto-switch to G.711
G.711U, G711A, G.723, G.729A/B, G.726
Switch Mode and PPPoE
T.38 compliant Group 3 Fax Relay up to 14.4kpbs and
auto-switch to G.711 for Fax Pass-through
Diffserve, TOS, 802.1 P/Q VLAN tagging
RTP/RTCP and RTSP
FXO Loop start, Current Disconnect.
Flexible DTMF transmission method,
User interface of In-audio, RFC2833, and SIP Info
SIP (RFC 3261)
TFTP and HTTP
TLS and SIPS (pending)
Syslog support,remote management using Web browser
REN3: Up to150 ft on 24 AWG line
Caller ID
Bellcore Type 1 & 2, ETSI, BT, NTT, and DTMF-based
CID
Polarity Reversal / Wink
Yes (Detection only). The PSTN lines will need to be
subscribed to PR service from the Service Provider.
EMC
Unicorn 60x0: EN55022 Class B, CFR Part 15 Class B,
EN55024;
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 8 of 25
Last Updated 8/2010
Unicorn 6040: FCC, CE (in addition)
Unicorn 60x0: EN60950-1 Unicorn 6080: UL60950-1 (in
addition)
Safety
4.2
Hardware Specification
TABLE 4: Hardware Specification Of Unicorn 60X0
LAN interface
LED
Universal Switching
Power Adaptor
Dimension
Weight
Temperature
Humidity
Compliance
2xRJ45 10/100Mbps
4 or 8 LEDs
(GREEN)
Input: 100-240V AC, 50/60Hz, 0.5A Max
Output: 9V DC, 2A
UL certified
225mm (L) x 172mm (W) x 42mm (H)
0.29 lbs (3.5 oz)
32~104°F
/ 0~40°C
10% - 90% (non-condensing)
FCC, CE
5 CONFIGURATION GUIDE
5.1
Configuration With Web Browser
The Unicorn 60x0 has an embedded Web server that will respond to HTTP GET/POST
requests. It also has embedded HTML pages that allow a user to configure the gateway
through any common web browser.
The GUI interface can be download at bellow:
http://www.hanlongtek.com/books/6080_gui.rar
This gui include bellow pages:
1. SCREENSHOT OF DEVICE STATUS PAGE
2. SCREENSHOT OF BASIC OPTIONS PAGE
3. SCREENSHOT OF SUPPER OPTIONS PAGE
4. SCREENSHOT OF PROFILE 1 PAGE
5. SCREENSHOT OF PROFILE 2 PAGE
6. SCREENSHOT OF FXO PORTS PAGE
5.1.1 Accessing The Web Configuration Menu
The Unicorn 60x0 HTML configuration menu can be accessed via LAN or WAN port:
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 9 of 25
Last Updated 8/2010
From the LAN port:
1. Directly connect a computer to the LAN port.
2. Open a command window on the computer
3. Type in “ipconfig /release”, the IP address etc. becomes 0.
4. Type in “ipconfig /renew”, the computer gets an IP address in 192.168.22.x segment by
default
5. Open a web browser, type in the default gateway IP address. http://192.168.22.1.
You will see the login page of the device.
From the WAN port:
The WAN port HTML configuration option is disabled by default from factory. To access
the HTML configuration menu from the WAN port:
1. Enable the “WAN Port Web Access” option via IVR option 12.
2. Find the WAN IP address of the Unicorn 60x0 using voice prompt menu option 02.
3. Access the Unicorn 60x0 Web Configuration page by the following URI via WAN port:
http:// Unicorn 60x0 -IP-Address (the Unicorn 60x0 IP-Address is the WAN IP address for
the Unicorn 60x0).
NOTE: If using a web browser to enter the configuration page, strip the leading “0”s
because the browser will parse in octet. (i.e. if the IP address is: 192.168.001.014, please
type in: 192.168.1.14).
5.2
End User Configuration
Once the HTTP request is entered and sent from a Web browser, the user will see a log in
screen. There are two default passwords for the login page:
User
Password:
Level:
End User Level
Administrator Level
1234
Only Status and Basic Settings
admin
Browse all pages
FIGURE 3: Screen-Shot Of Unicorn 60x0 Log-In Screen
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 10 of 25
Last Updated 8/2010
5.2.1 Status Page Definitions
DEVICE STATUS
Setting Options
Definitions
MAC Address
The device ID, in HEX format. This is a very important ID for
ISP troubleshooting.
WAN IP Address
This field shows IP address of device
Product Model
Show product model of this device
Software Version
Information of software
System Uptime
Show system uptime since last reboot
PPPoE Link Up
Indicates where the PPPoE connection is up if the
Uicorn2101 is connected to the DSL modem.
NAT
Indicate the NAT type behind which the device is when the
stun feature is defined.
Port Status
Indicate the current status of the device such as hook
(on/off),registion(registered/unregistered) etc.
5.2.2 Basic Settings Page
Setting options
BASIC OPTIONS SETTING
Definitions
Web Port
Default is 80.
IP Address
There are 3 modes under which the Unicorn 600x can
operate:
- If DHCP mode is enabled, then all the field values for the
Static IP mode are not used (even though they are still
saved in the chipset's memory). The Unicorn 600x will
acquire its IP address from the first DHCP server it
discovers from the office/home network it is connected to.
-To use the PPPoE feature, the PPPoE account settings
need to be set. The Unicorn 600x will attempt to establish
a PPPoE session if any of the PPPoE fields have been
entered with data.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 11 of 25
Last Updated 8/2010
- If Static IP mode is enabled, then the IP address, Subnet
Mask, Default Router IP address, DNS Server 1 (primary),
DNS Server 2 (secondary) fields will need to be
configured by the user. These fields are reset to zero by
default.
Time Zone
This parameter controls how the displayed date/time will
be adjusted according to the specified time zone.
Allow DHCP Option 2
If set yes and under DHCP mode,the device will try to get
to override Time Zone
option 2 from DHCP configure and overwrite Time Zone.
setting
Daylight Savings Time
This parameter controls whether the displayed time will be
daylight savings time or not. If set to Yes, then the
displayed time will be 1 hour ahead of normal time.
Device Mode
This parameter controls whether the device is working in
NAT router mode or Bridge mode. Need save the setting
and reboot the device before the setting start to work
LAN Subnet Mask
Sets the LAN subnet mask. Default value is 255.255.255.0
LAN DHCP Base IP:
Base IP for the LAN port which functions as a Gateway for
the subnet. Default value is 192.168.22.1
DHCP IP Lease Time:
Value is set in units of hours. Default value is 120hr (5
Days) The time IP address are assigned to the LAN clients
Port Map
Forwards a matching (TCP/UDP) port to a specific LAN IP
address with a specific (TCP/UDP) port
End User Password
This contains the password to access the
Configuration Menu. This field is case sensitive.
Web
If set to “Yes”, the unicorn600x will respond to the PING
Reply to ICMP on WAN
command from other computers, but it also is vulnerable
port
to the DOS attack. Default is No.
Wan Side Http Access
5.3
If this parameter is set to “No”, the HTML configuration
update via WAN port is disabled.
Super User Settings
The end-user needs to login to the Super user configuration page the same way as for the
basic configuration page.
FIGURE 4: Screenshot Of Super User Configuration
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 12 of 25
Last Updated 8/2010
5.3.1 Super Configuration Page Definitions
Setting options
Super Options
Definitions
Admin Password
This contains the password to access the Advanced
Web Configuration page. This field is case sensitive.
Only the administrator can configure the “Advanced
Settings” page. Password field is purposely left blank for
security reasons after clicking update and saved. The
maximum password length is 26 characters,only digit or
letter.
Home NPA
Local area code for North American Dial Plan.
Layer3 Qos
This field defines the layer 3 QoS parameter which can
be the value used for IP Precedence or Diff-Serv or
MPLS. Default value is 48.
Layer2 Qos
Value used for layer 2 VLAN tag. Default setting is blank
Data VLAN Tag
When using Bridge Mode, Data VLAN Tag is supported.
when your PC connect to LAN Port, data (from your PC
to switch) will be tagged with "Data VLAN Tag".
Stun sever is:
IP address or Domain name of the STUN server.
Keep-alive interval
This parameter specifies how often the Unicorn600x
sends a blank UDP packet to the SIP server in order to
keep the “hole” on the NAT open. Default is 20 seconds.
Minimum value is 20 seconds.
Firmware Upgrade
and Provisioning:
Upgrade or provisioning through TFTP or TFTP server.
--Upgrade Via:select HTTP or TFTP mode.
--Allow DHCP Option: support 66,128,150. If select
yes,device will get server information from DHCP option
and ignore the Config Server Path.
Option 66--TFTP server name(if you select Upgrade
Via->TFTP), HTTP server name(if you select Upgrade
Via->HTTP)
Option 128--TFPT Server IP address.(if you select
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 13 of 25
Last Updated 8/2010
Upgrade Via->TFTP), HTTP Server IP address(if you
select Upgrade Via->HTTP)
Option 150--TFTP server address.(if you selectUpgrade
Via->TFTP), HTTP server address(if you select
Upgrade Via->HTTP)
Authenticate Conf File
configure file would be authenticated before acceptance
if set to Yes
NTP server
This parameter defines the URI or IP address of the
NTP server which is used by the Unicorn 600x to set the
current date/time.
Allow DHCP Option 42 If set Yes,device can get NTP server from DHCP option
to override NTP server 42.
Syslog Sever
The IP address or URL of System log server. This
feature is especially useful for the ITSP (Internet
Telephone Service Provider)
Syslog level
Default is blank, the feature is useful for the Internet
Telephone Service Provider.
Download
Configuration
Device User can download configuration from the web page
and save to configuration file.
Call Progress Tones
Using these settings, users can configure tone
frequencies and cadence according to their preference.
By default they are set to North American frequencies.
Configure these settings with known values to avoid
uncomfortable high pitch sounds. ON is the period of
ringing (“On time” in ‘ms’) while OFF is the period of
silence. In order to set a continuous tone, OFF should
be zero. Otherwise it will ring ON ms and a pause of
OFF ms and then repeat the pattern.
Example configuration for N.A. Dial tone:
f1=350@-13,f2=440@-13,c=0/0;
Syntax: f1=freq@vol, f2=freq@vol,
c=on1/off1-on2/off2-on3/off3; [...] (Note: freq: 0 4000Hz; vol: -30 - 0dBm)
Restore
Configuration
User can restore the before configuration from the
configuration file saved at local pc
5.3.2 Profiles
Profiles are basically IP PBX / SIP Server configuration templates. If you have more than
one IP PBX system or SIP Server that you would like to use with the Unicorn 60x0, then
you can configure Profile 1 or 2. Note – Make sure you select the correct profile for each
channel under Channels WEBPAGE.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 14 of 25
Last Updated 8/2010
PROFILE PAGE DEFINITIONS
Settings Options
Definitions
Account active
SIP Server
Outbound Proxy
When set to Yes this profile is activated
SIP Server’s URI or IP address
SIP Outbound Proxy Server’s URI or IP address
This parameter defines whether the Unicorn 600x NAT
traversal mechanism will be activated or not.
If Choosing No,nothing to do.
If Choosing No, but send keep-alive, the Unicorn 600x will
periodically (every 20 seconds or so) send a blank UDP
packet (with no payload data) to the SIP server to keep the
“hole” on the NAT open.
NAT Traversal
If choosing STUN and a STUN server is also specified, then
the Unicorn 600x will behave according to the STUN client
specification. Under this mode, the embedded STUN client
inside the Unicorn 600x will attempt to detect if and what
type of firewall/NAT it is sitting behind through
communication with the specified STUN server. If the
detected NAT is a Full Cone, Restricted Cone, or a
Port-Restricted Cone, the Unicorn 600x will attempt to use
its mapped public IP address and port in all its SIP and SDP
messages. If choosing STUN with no specified STUN
server, the Unicorn 600x will periodically (every 20 seconds
or so) send a blank UDP packet (with no payload data) to
the SIP server to keep the “hole” on the NAT open.
If choosing UPNP, the embedded UPNP client inside the
Unicorn 600x will attempt to mapping ports with the router
by upnp protocol.
If set to “Yes”, Unicorn60x0 will use the first account among
Ports Using The Profile
the FXO PORTS of using the same profile.
Share With One
If set to “No”, you need configure one port one account in
Common Account
FXO PORTS page.
Auto Select Idle Port
(For Outgoing Call)
If set to “Yes”, Unicorn60x0 will auto-select an idle Line to
make outbound call to PSTN.
If set to “No”, you need configure one port one account in
FXO PORTS page, then it is the business of SIP SERVER
that it decide which idle FXO Port for outbound call.
Use DNS SRV
Default is No. If set to Yes the client will use DNS SRV for
server lookup
User ID is Phone
Number
If the Unicorn 600x has an assigned PSTN telephone
number, this field should be set to “Yes”. Otherwise, set it to
“No”. If “Yes” is set, a “user=phone” parameter will be
attached to the “From” header in SIP request
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 15 of 25
Last Updated 8/2010
SIP Registration
This parameter controls whether the Unicorn 600x needs
to send REGISTER messages to the proxy server. The
default setting is “Yes”.
Unregister on Reboot
Default is “No.” If set to “Yes”, then the SIP user will be
unregistered on reboot.
Register Expiration
This parameter allows the user to specify the time frequency
(in minutes) the Unicorn 600x refreshes its registration with
the specified registrar. The default interval is 60 minutes (or
1 hour). The maximum interval is 65535 minutes (about 45
days).
Outgoing call without
Registration
Default is No. If set to “Yes,” user can place outgoing calls
even when not registered (if allowed by ITSP) but is unable
to receive incoming calls.even when not registered (if
allowed by ITSP) but is unable to receive incoming calls.
Local SIP port
This parameter defines the local SIP port the Unicorn 600x
will listen and transmit. The default value for FXS port 1 is
5060. The default value for FXS 2 port is 5062.
Local RTP port
This parameter defines the local RTP-RTCP port pair the
Unicorn 600x will listen and transmit. It is the base RTP port
for channel 0. When configured, channel 0 will use this port
_value for RTP and the port_value+1 for its RTCP; channel
1 will use port_value+2 for RTP and port_value+3 for its
RTCP. The default value for FXS port 1 is 5004. The default
value for FXS 2 port is 5008.
Use Random Port
This parameter, when set to Yes, will force random
generation of both the local SIP and RTP ports. This is
usually necessary when multiple Unicorn 600x are behind
the same NAT.
Refer-To Use Target
Contact
Default is NO. If set to YES, then for Attended Transfer, the
“Refer-To” header uses the transferred target’s Contact
header information.
DTMF Payload Type
This parameter sets the payload type for DTMF using
RFC2833
DTMF in Audio
This parameter specifies the mechanism to transmit DTMF
digit in audio which means DTMF is combined in audio
signal(not very reliable with low-bit-rate codec),
Default is YES.
DTMF via RFC2833
This parameter specifies the mechanism to transmit DTMF
digit via RTP (RFC2833).
Default YES.
DTMF via SIP INFO
This parameter specifies the mechanism to transmit DTMF
digit via SIP INFO.
Default is NO.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 16 of 25
Last Updated 8/2010
Proxy-Require
SIP Extension to notify SIP server that the unit is behind the
NAT/Firewall.
USE NAT IP
NAT IP address used in SIP/SDP message. Default is
blank.
Preferred Vocoder
The Unicorn600x supports up to 5 different Vocoder types
including G.711 A-/U-law, G.726 (Supports bit rates 32K),
G.723.1, G.729A/B. The user can configure Vocoders in a
preference list that will be included with the same
preference order in SDP message. The first Vocoder is
entered by choosing the appropriate option in “Choice 1”.
The last Vocoder is entered by choosing the appropriate
option in “Choice 6”.
This field contains the number of voice frames to be
transmitted in a single packet. When setting this value, the
user should be aware of the requested packet time (used in
SDP message) as a result of configuring this parameter.
This parameter is associated with the first vocoder in the
above vocoder Preference List or the actual used payload
type negotiated between the 2 conversation parties at run
time. e.g., if the first vocoder is configured as G723 and the
“Voice Frames per TX” is set to be 2, then the “ptime” value
in the SDP message of an INVITE request will be 60ms
Voice Frames per TX
because each G723 voice frame contains 30ms of audio.
Similarly, if this field is set to be 2 and if the first vocoder
chosen is G729 or G711 or G726, then the “ptime” value in
the SDP message of an INVITE request will be 20ms. If the
configured voice frames per TX exceeds the maximum
allowed value, the Unicorn 600x will use and save the
maximum allowed value for the corresponding first vocoder
choice. The maximum value for PCM is 10(x10ms) frames;
for G726, it is 20 (x10ms) frames; for G723, it is 32 (x30ms)
frames; for G729/G728, 64 (x10ms) and 64 (x2.5ms) frames
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 17 of 25
Last Updated 8/2010
respectively.
G723 Rate
This defines the encoding rate for G723 vocoder. By default,
6.3kbps rate is chosen.
VAD
Default is No. VAD allows detecting the absence of audio
and conserve bandwidth by preventing the transmission of
"silent packets" over the network.
Symmetric RTP
Default is No. When set to Yes the device will change the
destination to send RTP packets to the source IP address
and port of the inbound RTP packet last received by the
device.
FAX Mode
Default is T.30(Fax Pass-Through), or T.38 (Auto Detect)
FoIP
Fax Tone Detection
Mode
Default is Callee. This decides whether Caller or Callee
sends out the re INVITE for T.38 or Fax Pass Through.
Jitter Buffer Type
Select either Fixed or Adaptive based on network
conditions.
Jitter Buffer Length
Select Low, Medium or High based on network conditions.
Dial Plan
Dial Plan Rules:
1. Accept Digits: 1,2,3,4,5,6,7,8,9,0 , *, #, A,a,B,b,C,c,D,d
2. Grammar: x - any digit from 0-9;
a. xx+ - at least 2 digits number;
b. xx. ?at least 2 digits number;
c. ^ - exclude;
d. [3-5] - any digit of 3, 4, or 5;
e. [147] - any digit 1, 4, or 7;
f. <2=011> - replace digit 2 with 011 when dialing
Example 1: {[369]11 | 1617xxxxxxx} Allow 311, 611, 911,
and any 10 digit numbers of leading digits 1617
Example 2: {^1900x+ | <=1617>xxxxxxx} Block any number
of leading digits 1900 and add prefix 1617 for any dialed 7
digit numbers
Example 3: {1xxx[2-9]xxxxxx | <2=011>x+} Allow any length
of number with leading digit 2 and 10 digit-numbers of
leading digit 1 and leading exchange number between 2 and
9; if leading digit is 2, replace leading digit 2 with 011 before
dialing.
3. Default: Outgoing - {x+}
Example of a simple dial plan used in a Home/Office in the
US:
{ ^1900x. | <=1617>[2-9]xxxxxx | 1[2-9]xx[2-9]xxxxxx |
011[2-9]x. | [3469]11 }
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 18 of 25
Last Updated 8/2010
Explanation of example rule (reading from left to right):
^1900x. - prevents dialing any number started with 1900
<=1617>[2-9]xxxxxx - allows dialing to local area code (617)
numbers by dialing 7 numbers and 1617 area code will be
added automatically
1[2-9]xx[2-9]xxxxxx |- allows dialing to any US/Canada
Number with 11 digits length
011[2-9]x. - allows international calls starting with 011
[3469]11 - allow dialing special and emergency numbers
311, 411, 611 and 911
Note: In some cases user wishes to dial strings such as
*123 to activate voice mail or other application provided by
service provider. In this case * should be predefined
inside dial plan feature and the Dial Plan should be: { [x*]+ }.
More information can be availabled at Dail Plan Notes.
Send Anonymous
If this parameter is set to “Yes”, the “From” header in
outgoing INVITE message will be set to anonymous,
essentially blocking the Caller ID from displaying.
Anonymous Call
Rejection
Default is No. If set to Yes, incoming calls with anonymous
Caller ID will be rejected with 486 Busy message.
Session Expiration
The session timer extension enables SIP sessions to be
periodically “refreshed” via a re-INVITE request.
Once the session interval expires, if there is no refresh via a
re-INVITE message, the session will be terminated.
Session Expiration is the time (in seconds) at which the
session is considered timed out, if no successful session
refresh transaction occurs beforehand. The default value is
180 seconds. Default is 180 seconds.
Min-SE
The minimum session expiration (in seconds). Default is 90
seconds.
Caller Request Timer
If selecting “Yes” the device will use session timer when it
makes outbound calls if remote party supports session
timer.
Default is NO.
Callee Request Timer
If selecting “Yes” the phone will use session timer when it
receives inbound calls with session timer request.
Default is NO.
If selecting “Yes” the device will use session timer even if
the remote party does not support this feature. Selecting
Force Timer
“No” will allow the device to enable session timer only when
the remote party support this feature.
To turn off Session Timer, select “No” for Caller Request
Timer, Callee Request Timer, and Force Timer.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 19 of 25
Last Updated 8/2010
Default is NO.
UAC Specify Refresher
As a Caller, select UAC to use the device as the refresher,
or UAS to use the Callee or proxy server as the refresher.
Default is Omit
UAS Specify Refresher
As a Callee, select UAC to use caller or proxy server as the
refresher, or UAS to use the device as the refresher.
Default is UAC.
Session Timer can be refreshed using INVITE method or
UPDATE method.
Force INVITE
Select “Yes” to use INVITE method to refresh the session
timer.
Default is NO.
Send 200 OK Until FXO
Has Detected Polarity Default No. Check with your PSTN carrier before set to Yes
Reversal
FXO Pick Up Incoming
Call After Receive 200 Default No.
OK Form Server
Special Feature
Choose the selection to meet some special requirements
from Soft Switch vendors.
Default is standard.
Volume Amplification
Voice path volume adjustment.
Rx is a gain level for signals transmitted by FXS
Tx is a gain level for signals received by FXS.
Default = 0dB for both parameters. Loudest volume: +6dB
Lowest volume: -6dB.
User can adjust volume of call on either end using the Rx
Gain Level parameter and the Tx Gain Level parameter
located on the FXS Port Configuration page.
If call volume is too low when using the FXS port (ie. the
ATA is at user site), adjust volume using the Rx Gain Level
parameter under the FXS Port Configuration page.
If voice volume is too low at the other end, user may
increase the far end volume using the Tx Gain Level
parameter under the FXS Port Configuration page.
PSTN AC Termination
You can select the AC termination by Country or by
Impedance.
Caller ID Scheme
select caller ID to suit standard of different area.
An adjustable value for the Caller ID signal to help this
Caller ID Minimum RX
device to recognize Caller ID from different networks. (-50
Level (dB)
-0dB. Default -30dB)
Caller ID Transport
Type
Hanlong Technology Co., Ltd
According to customer’s choice CID information will be
transferred from PSTN network to VoIP network using
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 20 of 25
Last Updated 8/2010
following rules:
1. via SIP from - PSTN CID is in the SIP From field
2. via P-Asserted-Identity - SIP From field uses the
pre-configured account user Id. PSTN CID is in the
P-Asserted-Identity field
3. Send anonymous - SIP From field uses "anonymous".
PSTN CID is put in the P-Asserted-Identity field
4. Disable - PSTN CID will not be sent. SIP From field uses
the pre-configured account user ID
PIN for PSTN Calls
Enter digits to authorize calling PSTN numbers from VOIP,
default is no.
PIN for VOIP Calls
Enter digits to authorize calling VOIP terminals from PSTN,
default is no.
5.3.3 Configuring The FXO Channels
Configuring the FXO channels on the Unicorn 60x0 is an easy process. Follow the GUI
interfaces. The Device Status page terms are defined in FXO Ports page
Setting Options
FXS PORT SETTING
Meaning
FXO Port
FXS Port Number
SIP User ID
User account information, provided by VoIP service
provider (ITSP). Usually in the form of digit similar to
phone number or actually a phone number.
Authenticate ID
SIP service subscriber’s Authenticate ID used for
authentication. Can be identical to or different from
SIP User ID.
Password
SIP service subscriber’s account password for
Unicorn 600x to register to (SIP) servers of ITSP.
Name
Name
Profile ID
Select the corresponding Profile ID (1/2)
Unconditional Call
Forward to VOIP
Enable PSTN
Disconnect Tone
Detection
PSTN Disconnect
Tone
Hanlong Technology Co., Ltd
Calls are unconditionally forwarded to the specified
VoIP phone number once users dial the FXO port PSTN
number
If set to Yes, arrived Busy Tone is used as the
disconnect signal.
This configuration should be configured by the VoIP
service provider. Some country use single frequency
tone to signal PSTN disconnection, some country use
double frequency tone. This setting can be configured
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 21 of 25
Last Updated 8/2010
to suit the telephone company’s standard in different
country.
Enable Polarity
Reversal Disconnect
Enable Terminate Call
After PSTN Silence
Timeout
PSTN Silence Timeout
If set to Yes, the Polarity Reversal is used as the
disconnect signal.
If set Yes, the device terminate the call when Silence
timer expire.
Silence timer value, default is 60 minutes.
Number of Rings
Number of rings for a PSTN incoming call to FXO port
before FXO port picks up, default 2
Min Delay Before Dial
PSTN(ms)
Default is 500ms. This needs to be equal to or greater
than the Current Disconnect threshold setting. Once the
threshold is reached the gateway can dial out. This
parameter should only be used if there are PSTN line
detection issues.
DTMF Digit
Volume(dB)
Default value is 11dB.
DTMF Digit
Length(x10ms)
Digit length and Dial Pause are port digit dialing
configurations; FXO needs to dial out digits for VOIP to
PSTN 1 stage calls, and unconditional call forward to
PSTN, and route to PSTN. Digit Length is the play time
for each digit.
Note: In order to receive the caller ID information, the
delay should be set to a value larger than the delay
required to complete the PSTN caller ID delivery.
Please note that the value will be multiplied by 10ms.
DTMF Dial
Pause(x10ms)
Dial pause is the time between 2 digits for the same
scenario as explained above.
Please note that the value will be multiplied by 10ms.
Stage Method(1/2)
This configuration is applicable for VoIP to PSTN calls
and indicates one or two stage dialing methods.
Unconditional Call
Forward to PSTN
5.4
Calls are unconditionally forwarded to the specified
PSTN phone number once users dial the FXO port
VoIP number. Each port can be setted independence.
Saving The Configuration Changes
Once a change is made, press the “Update” button in the Configuration Menu. The
Unicorn 60x0 will display the following screen to confirm that the changes have been
saved. To activate changes, reboot or power cycle the Unicorn 60x0 after all changes are
made.
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 22 of 25
Last Updated 8/2010
FIGURE 5: Screen-Shot Of Save Configuration
5.5
Rebooting From Remote
The administrator can remotely reboot the unit by pressing the “Reboot” button at the
bottom of the configuration menu. The following screen will indicate that rebooting is
underway.
FIGURE 6: Screen-Shot Of Rebooting
The user can re-login to the unit after waiting for about 30 seconds.
6 FIRMWARE UPGRADE
To upgrade software, Unicorn 60x0 can be configured with a TFTP server where the new
code image is located. The TFTP upgrade can work in either static IP or DHCP mode
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 23 of 25
Last Updated 8/2010
using private or public IP address. It is recommended to set the TFTP server address in
either a public IP address or on the same LAN with the Unicorn 60x0.
There are two ways to set up the TFTP server to upgrade the firmware, namely through
voice menu prompt or via the Unicorn 60x0’s Web configuration interface. To configure the
TFTP server via voice prompt, follow section 5.1 with option 06, once set up the TFTP IP
address, power cycle the ATA, the firmware will be fetched once the ATA boots up.
To configure the TFTP server via the Web configuration interface, open up your browser to
point at the IP address of the Unicorn 60x0. Input the admin password to enter the
configuration screen. From there, enter the TFTP server address in the designated field
towards the bottom of the configuration screen.
Once the TFTP server is configured, please power cycle the Unicorn 60x0.
TFTP process may take as long as 1 to 2 minutes over the Internet, or just 20+ seconds if
it is performed on a LAN. Users are recommended to conduct TFTP upgrade in a
controlled LAN environment if possible. For those who do not have a local TFTP server,
Hanlong technology provides a NAT-friendly TFTP server on the public Internet for
firmware upgrade. Please check the Service section of Hanlong’s Web site to obtain this
TFTP server’s IP address.
NOTES:
When Hanlong ATA boot up, it will send TFTP or HTTP request to download configuration
files, there are two configuration files, one is “cfg.txt” and the other is “cfg001fc1xxxxxx”,
where “001fc1xxxxxx” is the MAC address of the Unicorn 60x0. These two files are for
initial automatically provisioning purpose only, for normal TFTP or HTTP firmware upgrade,
the following error messages in a TFTP or HTTP server log can be ignored.
7 RESTORE FACTORY DEFAULT SETTINGS
There are two (2) methods for resetting your unit:
Reset Button
Reset default factory settings following these four (4) steps:
1. Unplug the Ethernet cable.
2. Locate a needle-sized hole on the back panel of the gateway unit next to the power
connection.
3. Insert a pin in this hole, and press for about 8 seconds.
4. Take out the pin. All unit settings are restored to factory settings.
IVR Command
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 24 of 25
Last Updated 8/2010
Reset default factory settings using the IVR Prompt (Table 5):
1. Dial “***” for voice prompt.
2. Enter “99” and wait for “reset” voice prompt.
3. Enter 862584658050
NOTE:
1. Factory Reset will be disabled if the “Lock keypad update” is set to “Yes”.
2. Please be aware by default the Unicorn 60x0 WAN side HTTP access is disabled. After
a factory reset, the device’s web configuration page can be accessed only from its LAN
port.
8 TECHNICAL SUPPORT CONTACT
Email: [email protected]
Hanlong Technology Co., Ltd
Unicorn 60x0 User Manual
Firmware 1.0.0.29
Page 25 of 25
Last Updated 8/2010