Download XiIIIPlus/R110XI/R170Xi User Guide

Transcript
142
Troubleshooting
Printer Diagnostics
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default
values. These values are active only until power is turned off unless you save them
permanently in memory. If the factory default values are permanently saved, a media
calibration procedure must be performed, and you must reset the head resistance value and the
verifier and applicator port settings to their required values.
To perform a FEED and PAUSE self test, complete these steps:
1. Turn Off (O) the printer.
2. Press and hold FEED and PAUSE while turning the power On (I).
3. Hold FEED and PAUSE until the first control panel light turns off.
The printer configuration is temporarily reset to the factory default values. No labels print
at the end of this test.
Communications Diagnostics Test
Do not perform the following test until all configuration and calibration parameters have been
set. For configuration information, see Control Panel LCD Displays on page 57.
This test is controlled from the control panel LCD display. See Set Communications Mode
on page 73. Figure 58 shows a typical printout from this test. Turn the printer power Off (O)
and then back On (I) to exit this self test and return to normal operation.
Note • This test label prints upside-down.
Figure 58 • Communications Diagnostics Test Label
13383L-002 Rev. A
XiIIIPlus/R110Xi/R170Xi User Guide
12/2/05