Download Operating Instructions Busch-Dimmer® Memory - Busch

Transcript
1473-1-7932 │ Rev. 01 │ 17.12.2012
Operating Instructions
Busch-Dimmer®
Pos : 2 /#N eus truktur #/Online-Dokumentation (+KN X)/Titelbl ätter/Di mmer/Titelbl att - 6550 @ 22\mod_1331881639539_15.doc x @ 203338 @ @ 1
Memory Touch-Type
Controller
6550 U-101
6550
=== Ende der Liste für T extmar ke Cover ===
Operating Instructions
Busch-Dimmer ®
Pos : 4 /#N eus truktur #/Online-Dokumentation (+KN X)/Inhalts verz eic hnis (--> Für alle D okumente <--)/Inhalts verz eichnis @ 19\mod_1320649044386_15.doc x @ 109653 @ @ 1
1
2
3
4
5
6
7
8
Safety ....................................................................................................................................................................... 3
Intended use ............................................................................................................................................................ 3
Environment ............................................................................................................................................................. 3
Operation ................................................................................................................................................................. 4
4.1
General ................................................................................................................................................... 4
4.2
Normal operation..................................................................................................................................... 4
4.3
Parallel operation (extension unit) ........................................................................................................... 4
4.4
Button mode ............................................................................................................................................ 5
4.5
Operation with Busch Watchdog flush-mounted sensors - type designation in the Busch Watchdog
program................................................................................................................................................... 5
4.6
Extension units ........................................................................................................................................ 5
4.7
Extension unit operation.......................................................................................................................... 6
4.8
Operation with the Busch Watchdog Presence 6813- ... or 6813/11-...................................................... 6
4.9
Comfort timer control element 6455 ........................................................................................................ 6
4.10
Adjusting the basic brightness (if necessary) .......................................................................................... 7
4.11
Restoring the memory function after a mains power failure .................................................................... 7
Technical data.......................................................................................................................................................... 8
Setup and function ................................................................................................................................................... 8
6.1
Features of function and equipment ........................................................................................................ 8
6.2
Possible combinations ............................................................................................................................ 9
Installation and electrical connection ..................................................................................................................... 10
7.1
Requirements for the electrician ........................................................................................................... 10
7.2
Mounting ............................................................................................................................................... 11
7.3
Installation with IR remote control ......................................................................................................... 12
7.4
Mounting with Busch Watchdog Flush-Mounted Sensors ..................................................................... 13
7.4.1
Mounting height / application ................................................................................................................ 13
7.5
Electrical connection ............................................................................................................................. 14
7.6
Extension unit input (parallel operation) ................................................................................................ 14
Commissioning ...................................................................................................................................................... 16
8.1
Setting the operating mode on the slide switch ..................................................................................... 16
8.2
IR control element ................................................................................................................................. 16
8.3
Fault rectification ................................................................................................................................... 17
=== Ende der Liste für T extmar ke TOC ===
Operating Instructions | 1473-1-7932
—2—
Operating Instructions
Busch-Dimmer ®
Safety
Pos : 6 /#N eus truktur #/Online-Dokumentation (+KN X)/Ü bersc hriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.doc x @ 103357 @ 1 @ 1
1
Safety
Pos : 7 /#N eus truktur #/Online-Dokumentation (+KN X)/Sicherheits hinweis e und Hi nweis e (--> F ür all e D okumente <--)/Warnhinweis e/Sicherheit - 230 V @ 18\mod_1302606816750_15.doc x @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos : 8 /#N eus truktur #/Online-Dokumentation (+KN X)/Ü bersc hriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bes timmungsgemäß er Gebrauc h @ 18\mod_1302763321316_15.doc x @ 103483 @ 1 @ 1
2
Intended use
Pos : 9 /#N eus truktur #/Online-Dokumentation (+KN X)/Bes timmungsgemäß er Gebrauc h (--> Für alle Dokumente <--)/Bus ch-Di mmer /Besti mmungsgemäß er Gebr auch @ 23\mod_1335350449857_15.doc x @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter
"Setup and function".
Pos : 10 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/U - Z/U mwelt @ 18\mod_1302614158967_15.doc x @ 103383 @ 1 @ 1
3
Environment
Pos : 11 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Hinweis e - U mwelt/Hi nweis - U mwelt - Hi nweis El ektr ogeräte @ 18\mod_1302763973434_15.doc x @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos : 12 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Hinweis e - U mwelt/Hi nweis - U mwelt - Entsorgung Elektroger äte @ 20\mod_1325760695972_15.doc x @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos : 13 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
—3—
Operating Instructions
Busch-Dimmer ®
4
Operation
Operation
Pos : 14 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/A - F /Bedi enung @ 11\mod_1279185541649_15.doc x @ 83043 @ 1 @ 1
Pos : 15 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/Di mmer/Bedi enung - 6550 @ 22\mod_1331884277318_15.doc x @ 203458 @ 22222222222 @ 1
4.1
General
Lighting systems can be switched or dimmed directly via the touch-type controller or alternatively via additionally
connected push-buttons (extension units). For operation, the flush-mounted insert has operating elements
attached.
Note
The brightness value set last is retained after the switch-off (memory function). The memory
touch-type controller only starts to control after the first operation from "bright" to "dark", the
dimming direction being reversed with each stop. At maximum brightness, the memory touch-type
controller stops, at minimum brightness the dimming direction changes.
If the dimmer is switched "brighter", the dimming direction is from minimum to maximum
brightness.
4.2
Normal operation
For operating mode "Normal operation" the sliding switch must be set on I - compare chapter "Commissioning".
Activation
•
Tap briefly on the control element.
The brightness value last set (memory value) will be automatically set.
After each dimming process the dimming direction is reversed and it is set darker or brighter.
Increasing the brightness
•
Keep the control element pressed.
The current brightness value is adjusted brighter until the maximum brightness value has been reached.
Reducing the brightness
•
Keep the control element pressed.
The current brightness value is adjusted darker until the minimum brightness value has been reached. If the
control element continues to be pressed, the dimming direction changes and it is adjusted brighter again until
the maximum brightness value has been reached.
Deactivation
•
Tap briefly on the control element.
The current brightness value is saved as a memory value and the lighting system is deactivated.
4.3
Parallel operation (extension unit)
•
Press the control element of the extension unit.
All memory touch-type controllers are switched and dimmed simultaneously via the extension unit.
Lighting systems can also be operated with uniform brightness values:
•
Keep the control element of the extension unit pressed for 10 seconds.
The lighting systems are set to the maximum brightness value and can then be operated "synchronously".
Operating Instructions | 1473-1-7932
—4—
Operating Instructions
Busch-Dimmer ®
Operation
4.4
Button mode
Only valid for 6550 U …
For operating mode "Button mode" the sliding switch must be set on II - compare chapter "Commissioning".
For button mode the relay output acts as NO contact button. Button mode can be implemented both via the
mechanical control elements, the IR control element 6066- ... and via the extension unit input.
•
Tapping: The relay is activated for a brief period.
•
Holding: The relay switches for the duration of the activation.
4.5
Operation with Busch Watchdog flush-mounted sensors - type designation in the Busch
Watchdog program
Note
In these operating instructions both the Busch Watchdog (Art. No. 6810-21 ... -10 ...) and the
comfort sensors (Art. No. 6800- ... -10 ... (M)) are designated as "flush-mounted sensors."
•
Please pay attention to the correct type assignment in the description.
The type designation can be found on the rear side of the respective device.
After the interruption or activation of the mains voltage the memory touch-type controller switches the connected
loads in dependence of the type of sensor as follows:
Flush-mounted sensor type
ON period
6810-21 … -10 …
80 seconds
6800- … -104(M) or higher
Dependent on the setting at the flush-mounted sensor (at least 1
minute at a time setting of < 1 minute). Exception is short-time
pulse
.
Note
The On period is independent of the brightness set on the sensor.
4.6
Extension units
The following are possible extension units:
Normally-open contact button, e.g. 2020 US (Switching / dimming possible via extension unit button. If a
Busch-Watchdog attachment is used with the 6550 U-10, ... only switching is possible).
– Flush-mounted insert 6805 U in combination with Busch Watchdog 180 sensors
Operating Instructions | 1473-1-7932
—5—
Operating Instructions
Busch-Dimmer ®
Operation
4.7
Extension unit operation
In connection with flush-mounted sensors, extension unit operation is possible via two models:
Activation via NO contact button
Extension unit insert 6805 UPassive extension unit operation by means of NO push-button
The function performed on the NO contact push-button causes the connected loads to be switched on as follows:
Flush-mounted sensor type
ON period
6810-21… - 10 …
80 seconds
6800- … - 104(M) or higher
Depending on the setting on the flush-mounted sensor
Note
The On period is independent of the brightness set on the sensor.
Deactivation / dimming is not possible via the extension unit. Multiple activation when the lighting
is switched on leads to a "reset" of the previously expired time.
Active extension unit operation (Busch Watchdog) with 6805 U and flush-mounted sensors
Since the main unit and extension unit each have a separate twilight value setting the current brightness
conditions at the mounting position can be taken into consideration individually.
The actual switch-OFF delay results when adding the time set on the main unit and on the extension unit. In
connection with flush-mounted sensors 6800- ... -104(M) or higher, it is recommended to operate the extension
units with the short-pulse time setting when the times set on the main unit are to be precisely adhered to.
Note
Further information on the respective flush-mounted sensor is contained in the respective
operating instructions.
4.8
Operation with the Busch Watchdog Presence 6813- ... or 6813/11Detailed information is contained in the respective operating instructions.
4.9
Comfort timer control element 6455
Detailed information is contained in the respective operating instructions.
Operating Instructions | 1473-1-7932
—6—
Operating Instructions
Busch-Dimmer ®
Operation
4.10
Adjusting the basic brightness (if necessary)
With the 6550 U-10 ..., the basic brightness is set via the attached control element. With the 6550, it is set via a
button connected to terminal 1.
1. Keep the control element pressed for approximately 30 seconds to enter the programming mode.
The memory touch-type controller has switched to "Programming mode" when it jumps automatically to a
minimum brightness value.
2. Set the lighting to the desired brightness value and then release the button.
Approximately 30 seconds after releasing the button the memory touch-type controller jumps automatically
back to maximum. This indicates that the setting process has been carried out correctly.
If this is not the case, please repeat the adjustment of the basic brightness.
4.11
Restoring the memory function after a mains power failure
During a mains power failure the memory touch-type controller loses the previously set brightness value and
switches on with the maximum brightness at its next operation. The memory function is lost.
Procedure for restoring the memory function:
1. Adjust the lighting according to the desired intensity.
2. Switch the lighting off.
During the next activation the previous value is saved and set automatically.
Pos : 16 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
—7—
Operating Instructions
Busch-Dimmer ®
Technical data
Pos : 17 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/S - T /Technisc he Daten @ 11\mod_1279185386320_15.doc x @ 83019 @ 1 @ 1
5
Technical data
Pos : 18 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Technisc he Daten/Di mmer/Technisc he Daten - 6550 @ 22\mod_1331882282394_15.doc x @ 203398 @ @ 1
General
Nominal voltage
230 V AC ± 10 %, 50 Hz
Nominal power
700 W / VA
Nominal current
4 A cos ϕ 0,9 or 3 A cos ϕ 0,5
Power consumption
1 W / VA
Extension unit input
230 V AC ± 10 %, 50 Hz
Control voltage
1 ... 10 V DC
Control current
Maximum 50 mA DC
Module width
2 MW (1 MW = 18 mm) applies only to Modular DIN Rail Component (MDRC)
Ambient temperature range
0 ...35 °C
Pos : 19 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ 1 Leerzeil e Abs tand ++++++++++++ @ 24\mod_1337929289045_0.doc x @ 213673 @ @ 1
Pos : 20 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/A - F /Aufbau und Funkti on @ 11\mod_1279185435352_15.doc x @ 83027 @ 1 @ 1
6
Setup and function
Pos : 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Lastarten/Lastarten Gl üh | Halo | NV-Hal o mit konv-Trafo @ 23\mod_1335534706839_15.doc x @ 208833 @ @ 1
The device is intended for the activation of the following types of loads:
230 V incandescent lamps
230 V halogen lamps
Low-voltage halogen lamps with conventional transformers
Pos : 22 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ 1 Leerzeil e Abs tand ++++++++++++ @ 24\mod_1337929289045_0.doc x @ 213673 @ @ 1
Pos : 23 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/A - F /Funkti ons- und Aus stattungs mer kmal e @ 23\mod_1336557630140_15.doc x @ 209136 @ 2 @ 1
6.1
Features of function and equipment
Pos : 24 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/Di mmer/F unkti onen - 6550 @ 22\mod_1331886596807_15.doc x @ 203534 @ @ 1
•
•
•
•
•
3-wire connection system (neutral conductor is required)
For LED control via ballasts
Without control element
Non-illuminable
With integrated inrush-current limiter
Pos : 25 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
—8—
Operating Instructions
Busch-Dimmer ®
Setup and function
Pos : 26 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/G - L/Kombinati ons möglichkeiten @ 19\mod_1320312769153_15.doc x @ 109520 @ 2 @ 1
6.2
Possible combinations
Pos : 27 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Kombi nations möglichkeiten/Di mmer/Kombinati ons möglichkeiten - 6550 @ 22\mod_1331886640744_15.doc x @ 203549 @ @ 1
Flush-mounted
MDRC
6550 U-101
6550
X
X
6597
6597
X
2020 US
X
3099
X
2021/6 UK
X
6066- …
X
6543- …
Note
When using control element 6543- …, remove the plugged-in illuminating element since it cannot
be illuminated when combined with memory touch-type controller 6550 U-10 … .
Pos : 28 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
—9—
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
Pos : 29 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/M - O/M ontage und el ektrisc her Anschl uss @ 23\mod_1336477157864_15.doc x @ 209033 @ 1 @ 1
7
Installation and electrical connection
Pos : 30 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 23\mod_1336558868201_15.doc x @ 209164 @ @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos : 31 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - F ac hkenntniss e @ 23\mod_1336559183027_15.doc x @ 209179 @ 2 @ 1
7.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
•
Incorrect installation endangers your life and that of the user of the electrical system.
•
Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
•
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
•
Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos : 32 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
— 10 —
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
Pos : 33 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/M - O/M ontage @ 18\mod_1302615960458_15.doc x @ 103424 @ 2 @ 1
7.2
Mounting
Pos : 34 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - 230 V @ 18\mod_1302606816750_15.doc x @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos : 35 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/alle Geräte/M ontage - U P-Dos en - D IN 49073-1 oder geeignetes Aufputzgehaeus e - Ohne Doc vari abl e @ 25\mod_1340354979636_15.doc x @ 219890 @ @ 1
The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or
suitable surface-mounted housings.
Pos : 36 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/alle Geräte/M ontage - H uts chi enen nac h D IN EN 500022 - Ohne Doc vari abl e @ 20\mod_1325766045140_15.doc x @ 136603 @ @ 1
The MDRC must only be installed on mounting rails according to DIN EN 500022. The MDRC is latched onto the
mounting rail.
Pos : 37 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/Di mmer/Montage - 6550 @ 22\mod_1331883464194_15.doc x @ 203413 @ 223 @ 1
Note
We recommend using a flush-mounted box with an installation depth of 60 mm. In combination
with Presence Watchdog 6813- ..., it must be installed on the ceiling of a room.
Warning
Electric voltage!
There is the risk of personal injury and damage to property. The control output (1 ... 10 V) of the
memory touch-type controller is no low-voltage safety (SELV).
Operating Instructions | 1473-1-7932
— 11 —
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
7.3
Installation with IR remote control
The memory touch-type controller 6550 U-10 ... can be used as a component within the IR remote control system.
In this case, the memory touch-type controller must be combined with the IR remote control element 6066- ...
When installing with remote control the installation site should lie within the IR receiving range - see Fig. 1 and
Fig. 2. Please note that the IR receiving range may vary due to extraneous light (e.g., sunlight, illumination).
Coverage in connection with IR control element 6066- ...
Fig. 1:
Coverage
Fig. 2:
Detection range
Detection range in connection with IR control element
6066- ...
Operating Instructions | 1473-1-7932
— 12 —
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
7.4
Mounting with Busch Watchdog Flush-Mounted Sensors
The memory touch-type controller 6550 U-10 can be used in combination with the Busch-Watchdog 180 flushmounted sensors 6810-21 -10 ..., 6800- ... -104(M) or higher. In this case, a switching function (ON/OFF) is
possible, but no dimming function.
The mounting height depends on the selection of the flush-mounted sensor - table. For further information on
mounting height, the adjustment of the flush-mounted sensors, see the relevant operating instructions of the
respective flush-mounted sensor. For push-button operation please note the following:
– The phase of the extension unit and the phase of the supply voltage must be the same and be connected to
an electric circuit.
– When laying lines, ensure that there is sufficient distance between the control lines and load lines (at least
5 cm).
– The maximum line length of the extension unit cables is 100 m.
– Changing the line routing of existing two-way circuits and cross connections is not necessary.
7.4.1
Mounting height / application
To guarantee an optimum function of the flush-mounted sensors, please observe the following table.
F lus h-mounted s ens or
Mounting height, applic a tion
ty pe
6810-21…-101,
6800- … -104
B uilt-in pos ition of c onnec ting s c r ews
6550U -10 …
0.8 – 1.2 m
Bottom
0.8 – 1.2 m (stairwell)
6800- … -104M
2.0 – 2.5 m (room monitoring)
Top
Pos : 38 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
— 13 —
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
Pos : 39 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/A - F /El ektrisc her Ansc hluss @ 21\mod_1328177051724_15.doc x @ 138042 @ 2 @ 1
7.5
Electrical connection
Pos : 40 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Ansc hlus s/Di mmer/Ansc hluss - 6550 @ 22\mod_1331884024926_15.doc x @ 203443 @ 2 @ 1
Caution
Risk of damaging the device due to excessive voltage!
When using different phases for the supply input L and the extension unit input 1, the voltage there
could be too high (380 V).
Connect supply input L and the push-buttons for extension unit input 1 to the same phase.
Note
If a protective conductor connection is used, ensure that it is properly connected to the lamp and
to the electronic ballast units.
7.6
Extension unit input (parallel operation)
Parallel operation - Fig. and Fig. 3
The memory touch-type controller can be operated via an extension unit. In the process, the following must be
observed:
– The maximum cable length depends on the admissible ripple voltage of the extension unit inputs. The ripple
voltage, however, must not exceed 100 V. In practice this corresponds to a cable length of approx. 100 m.
– The number of the push-buttons (e.g. 2020 US) at a cable length of 100 m is unlimited.
If illuminated push-buttons (e.g. 2020 USGL) are used, only push-buttons with a separate N-connection are
admissible. Contact-parallel illumination is not admissible.
– Do not install control and load line in the one cable, to prevent unwanted switching processes.
For one electronic ballast
For several electronic ballasts
Fig. :
Activation of the 6550 U-10 ... (flush-mounted version)
Operating Instructions | 1473-1-7932
— 14 —
Operating Instructions
Busch-Dimmer ®
Installation and electrical
connection
For one electronic ballast
For several electronic ballasts
Fig. 3:
Activation of the 6550 (rail-mounted version)
Fig. 4:
6550 U-10 … for activation of several electronic ballasts >= 50 mA
Note
Relay a serves for contact amplification, and is not included in the scope of supply.
Pos : 41 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
— 15 —
Operating Instructions
Busch-Dimmer ®
Commissioning
Pos : 42 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/G - L/Inbetriebnahme @ 11\mod_1279185496977_15.doc x @ 83035 @ 1 @ 1
8
Commissioning
Pos : 43 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Inbetriebnahme/Di mmer/Inbetriebnahme - 6550 @ 22\mod_1331884004379_15.doc x @ 203428 @ 22 @ 1
8.1
Setting the operating mode on the slide switch
Only valid for 6550 U-10…
The memory touch-type controller offers two different
operating modes - see also chapter "Operation".
– Normal mode = Setting bottom I (delivery status)
– Button mode = Setting top II
Fig. 5:
8.2
Slide switch
IR control element
Only valid for IR remote control
Mounting the IR control element
1. In the case of IR control element 6066-..., set the desired address first – see Fig. 6.
2. Plug the control element onto the flush-mounted version of the memory touch-type controller.
Ensure that the IR control element does not jam in the frame.
Dismounting the IR control element
•
Use the notches on the right and left of the control element to lever it off.
Addressing of the IR control element
The address of IR control element 6066-… is is set on
number 1 at the factory.
1. If necessary, change the address on the rear of the
control element via the address wheel.
2. Observe the "IR receiving range" when addressing - Fig.
1 and Fig. 2.
Fig. 6:
Addressing
Pos : 44 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-7932
— 16 —
Operating Instructions
Busch-Dimmer ®
Commissioning
Pos : 45 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/S - T /Stör ungs bes eitigung @ 21\mod_1330945986708_15.doc x @ 201048 @ 2 @ 1
8.3
Fault rectification
Pos : 46 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Stör ungs bes eitigung/Di mmer/Störungsbes eitigung - 6550 @ 22\mod_1331886174784_15.doc x @ 203519 @ @ 1
Diagnosis
Possible cause
Fault rectification
The device is permanently set to maximum
Control voltage (1 V ... 10 V) is not
Connect the control voltage (1 V ... 10 V)
brightness
connected
–
Light does not come on
Switch the mains power supply OFF / ON
Minimum brightness is set too high
Adjustment minimum brightness
Control voltage (1 V ... 10 V) has short-
Rectify short-circuit
circuited
–
Switch the mains power supply OFF / ON
Minimum brightness is set too low
Adjustment minimum brightness
Line-side fuse is defective
Replace fuse
Fluorescent lamp is defective
Replace fluorescent lamp
Electronic ballast is defective
Replace electronic ballast
Controller is defective
Replace controller
Only valid for 6550 U-10…
Diagnosis
Possible cause
Fault rectification
LED of control element (6066-...) is OFF
Infrared detection range influenced by
Remove extraneous light
extraneous light (e.g. sunlight,
illumination)
LED of 6066-... flashes continuously
No mains power
Connect mains power
Infrared detection range influenced by
Remove extraneous light
extraneous light (e.g. sunlight,
illumination)
LED of 6066-... does not flash at
No incoming signal
Check reception of infrared signal
transmission signal
Battery of IR remote control or wall-
Replace battery
mounted transmitter is empty
Receiver outside if transmission signal
Check infrared detection range
=== Ende der Liste für T extmar ke Content ===
Operating Instructions | 1473-1-7932
— 17 —
Operating Instructions
Busch-Dimmer ®
A member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.com
[email protected]
Central sales service:
Phone:
+49 (0) 2351 956-1600
Fax:
+49 (0) 2351 956-1700
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained therein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright© 2012 Busch-Jaeger Elektro GmbH
All rights reserved
=== Ende der Liste für T extmar ke Bac kc over ===
1473-1-7932 | Rev. 01 | 17.12.2012
Pos : 48 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Rüc ksei ten (--> Für alle Dokumente <--)Rüc ks eite - Busc h-J aeg er - Allgemein (2013-01-03 09:23:43) @ 28\mod_1347009779995_15.doc x @ 232282 @ @ 1