SPECIFICATION
•
Input voltage: AC120V 60Hz
•
Rated power: 57W
•
HEPA type: 99.5%
•
Ideal area: 269 sq. ft.
•
Noise level (dbA): High 48 / Med 39 / Low 28
•
Wind capacity (CFM): Strong 115 / Middle 74 / Silent 50
•
Unit weight: 11.7 lbs
•
Product size: 16.14 x 6.89 x 17.13 in.
CORRECT DISPOSAL OF THIS PRODUCT
Products bearing the crossed out bin symbol are not to be
disposed with your general household waste. For the correct
collection and treatment of these products, take them to the
collection points designated by your local authority. Alternatively
contact the retailer who sold you the product.
HEPA Air Purifier with
Ion Flow Technology
AC-7014G (Green)
AC-7014W (White)
Thank you for your purchase.
Please read this manual thoroughly before use.
Please keep in a safe place for future reference.
CONTENTS
SAFETY INSTRUCTION
IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING.
SAFETY INSTRUCTION ……………………………… 1
CAUTIONS CONCERNING OPERATION .…………. 1
1. Place the unit on a flat level floor. Unit may not work properly on an
uneven floor.
2. Keep unit away from heat sources such as stoves, radiators or heaters.
AIR PURIFICATION SYSTEM ……………………….. 2
3. Place unit in an area that is out of the reach of children.
PARTS IDENTIFICATION ………………………………2
4. DO NOT use the unit if the power cord or plug is damaged or the
FUNCTION …………………………………………….. 3
connection to the wall outlet is loose. If the power cord is damaged, it
OPERATION …………………………………………… 4
must be replaced by the manufacturer or similarly qualified person in
MAINTAINENCE ………………………………………. 5
REPLACEMENT FILTERS AND UV BULB ……….
5
order to avoid a hazard.
5. Always unplug the unit before cleaning.
6. DO NOT move or tilt the unit while in operation. Turn off and unplug
ASSEMBLY ……………………………………………. 6
WARRANTY
before moving.
7. NEVER immerse the unit in water or any other liquid. Keep unit away
from any water sources such as vases and drinking cups.
8. DO NOT insert fingers or foreign objects into the air intake or air outlet.
9. DO NOT operate when using aerosol insecticides or in rooms where
there is oily residue, incense, sparks from lit cigarettes, chemical fumes
FEATURES
1. Washable Pre-Filter
or under a humid condition.
10. This unit is designed for indoor use only. Keep away from direct sunlight.
2. Anti-Bacterial Pre-Filter
3. HEPA Filter
CAUTIONS CONCERNING OPERATION
4. Carbon Filter
•
NEVER operate the unit without the filter.
•
DO NOT wash and reuse the HEPA filter.
•
DO NOT block the air intake and outlets.
•
DO NOT sit or place objects on top of the unit.
5. UV Lamp + TiO2 Filter
6. Ion Flow Technology
7. CADR: 105
NOTE: this appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities; or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
1
AIR PURIFICATION SYSTEM
FUNCTION
•
Pre-Filter (black sponge): Captures the larger particles to
enhance the durability and performance of the other filters.
•
Anti-Bacterial Pre-Filter: First stage of capturing and
removing bacteria and microorganisms.
•
HEPA filter: A high-efficiency air filter that captures 99.5%
of airborne pollutant particles as small as 0.3 microns,
including spores, pollen, mold, pet dander and dust.
•
Activated Carbon Filter: Helps remove household odors.
•
TiO2 (Titanium Oxide) Filter + UV: Photo catalytic
oxidation is achieved when UV ray combines with a TiO2coated filter. This process creates hydroxyl radicals and
super-oxide ions, which are highly reactive electrons. These
electrons aggressively combine with other elements in the
air, such as bacteria and volatile organic compounds (VOC),
which are harmful pollutants. Once bound together, the
chemical reaction takes place between the super-charges
ion and the pollutant, effectively “oxidizing” or burning the
pollutant. This breaks the pollutant down into harmless
carbon dioxide and water molecules.
•
UV Light: Sterilizes the air by breaking down
microorganisms, such as germs, viruses, bacteria, fungi,
mold, etc. Effectively destroys the nucleic acids in these
microorganisms so their DNA is disrupted and destroyed.
•
Ion Flow Technology: Generates negative ions to attract
particles, such as dust, bacteria, pollen and many other
allergens, which are positively charged. Once bonded, the
particles become heavy and falls to the ground and out of
your respiratory system.
Ion Flow
PARTS IDENTIFICAION
Ion Flow
2
3
OPERATION
MAINTAINENCE
For optimum performance of this air cleaner, please clean unit
and filters periodically. Before cleaning, be sure to turn unit off
and unplug the power cord.
TIMER
indicator lights
Housing
• Wipe the body with soft and clean cloth. For more stubborn
stains, use a soft cloth dampened with warm water.
• Never use volatile fluids, such as paint thinner, polishing
powders, benzene, etc.
UV/ION FLOW
button &
indicator light
TIMER button
SPEED button
& indicator light
POWER ON/OFF
button
Power ON/OFF button:
ƒ Turn unit on/off
ƒ When powered on, indicator light is lit
SPEED button and indicator light:
ƒ Fan speed selection. Press to select fan speed:
Medium (orange) → High (red) → Low (green)
ƒ Unit starts up at Medium speed.
TIMER button and TIMER indicator lights:
ƒ Press to set timer: 2Hr → 4Hr → 8Hr
UV/ION FLOW button:
ƒ Turn UV/Ion Flow function On and Off
4
Pre-Filter (black sponge)
• Remove front panel and clean with handheld vacuum or
brush attachment of large vacuum.
• If excessively dirty, remove from HEPA filter frame and wash.
Only the black sponge is washable.
• When washing, use a soft brush with lukewarm water. Do
not use metal brushes or scrubs.
• After washing, allow to air dry in shade until completely dry.
HEPA Filter / Carbon Filter / TiO2 Filter
• These filters are NOT washable and should be replaced
periodically depending on usage and environment. On
average, replace once every 3 to 6 months.
• Filter life is greatly reduced with in poor environments.
Presence of cigarette smoke or pet dander can quickly clog
filters, please check filters regularly and replace as needed.
• Please dispose replaced filters according to local disposal
regulations.
REPLEACEMENT FILTERS AND UV BULB
Model: HEPA-7014 (Pre-filter+Anti-bacteria pre-filter+HEPA)
Model: CARBON-7014 (Carbon filter)
Model: TiO2-7014 (TiO2 filter)
Model: LAMP-7014 (UV bulb)
5
ASSEMBLY
To remove front panel, pull and lift upwards.
Your Guarantee
If this product is found to be faulty as a result of faulty materials or
workmanship within one year from date of purchase, it will be repaired free of
charge.
Filters must be placed in correct order:
This guarantee is subject to the following terms:
• Sunpentown must be notified of the fault.
• Proof of purchase must be presented to Sunpentown’s nominated
representative.
• The warranty will be void if the product if modified, misused or repaired
by an unauthorized person.
• The warranty after repair will not be extended beyond the original oneyear period.
• All replacement parts will be new or reconditioned.
• Parts, which are replaced, become the property of Sunpentown.
• The warranty applies for the use of the product in the USA only.
What is NOT COVERED:
•
•
•
Replace front panel, align clips at bottom and push in gently:
•
•
Warranty does not include freight charges.
Incidental or consequential damage caused by possible defects with this
product.
Damage to product caused by improper power supply voltage, accident,
fire, floods or acts of nature.
Failure of product resulting from unauthorized modifications to the
product.
Improper installation or failure to perform the necessary maintenance.
This GUARANTEE is in addition to your Statutory Rights
SUNPENTOWN INTERNATIONAL INC.
Tel: 1-800-330-0388
[email protected]
www.sunpentown.com