Download American Standard 7871.712.002 Installation Guide

Transcript
Installation
Instructions
Spread Lavatory Faucet with the
Speed Connect™ Drain
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
7871.702
7871.712
7871.722
7871.732
7881.702
7881.712
7881.722
7881.732
Certified to comply with ANSI A112.18.1
Speed Connect Drain*
U S 6 0 4 0 4 R ev. 1 . 3
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Screwdriver
1
INSTALL SPOUT
Channel Locks
CAUTION
Adjustable Wrench
Tubing Cutter
Turn off hot and cold water
supplies before beginning.
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure
the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting
hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
1A
Fig. A.
1
2
3
INSTALL VALVE BODY
7
Place RUBBER RING (9) into SCUTCHEON (10).
Install LOCKNUT (11) onto VALVE BODY (8).
From under side of mounting surface, install VALVE BODY (8) through valve
mounting holes. Threads of VALVE BODY (8) should extent at least 5/16
of a inch above mounting surface top. Fig. B. Thread ESCUTCHEON (10)
onto VALVE BODY (8) until snug against internal stop. If necessary, adjust
LOCKNUT (11).
Hand tighten LOCKNUT (11) to secure VALVE BODY (8).
Repeat above steps for opposite VALVE BODY (8A).
4
SLOT
5
6
12
1
10
9
5/16'' MIN.
10
MOUNTING
SURFACE
9
8A
Fig. B.
11
8
8
11
7871 SERIES
1
2
POP-UP DRAIN
Fig. A.
Fig. B.
Remove CLEAR PLASTIC COVER (1).
1
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
3
DRAIN
BODY
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
2
3
REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
4
Fig. A.
1
Fig. B.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
4
2
3
4
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
REAR OF SINK
DRAIN
OUTLET
1
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
6
FLANGE GASKET AND POP-UP KNOB
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
4
3
5
1
2
Fig. A.
Fig. B.
1
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
U S 6 0 4 0 4 R e v. 1 . 3
2
7
ATTACH CABLE CONNECTOR
Fig. A.
Fig. B.
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
1
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
2
1-1/4” O.D.
8
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
1
Note: If STOPPER (2) does not open and close properly then refer
to the “troubleshooting section” of these instructions.
2
9
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED
AND MUST BE PURCHASED SEPARATELY.
Thread TEE BODY (4) to SPOUT SHANK (5).
Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use
adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1A
5
COUPLING
NUT
1
1/2" PIPE THREAD
7
4
6
3/8 O.D.
BULL-NOSE
RISERS
2
FLEXIBLE
SUPPLIES
HOT
6A
7A
COLD
3
COMPRESSION
NUT
FERRULE
3/8 COMPRESSION
CONNECTION
U S 6 0 4 0 4 R e v. 1 . 3
3
10
INSTALL HANDLES (Lever)
4
Turn VALVE into OFF position.
3
Push ADAPTER (1) into HANDLE
BASE (2) in a way that the male
square on the ADAPTER (1) fits
in the female square of the
HANDLE BASE (2).
6
2
Push HANDLE BASE (2) and
ADAPTER (1) onto VALVE STEM (5).
1
Check alignment, if not satisfactory
aligned;
5
Push out ADAPTER (1) carefully.
Turn ADAPTER (1) either 45˚ or 90˚
so that male square on ADAPTER (1)
catches different female square in
HANDLE BASE (2).
Secure HANDLE BASE (2) with HANDLE SCREW (3).
4
4
3
6
Push ADAPTER (1) into HANDLE
BASE (2) in a way that the male
square on the ADAPTER (1) fits
in the female square of the
HANDLE BASE (2).
7
3
Push HANDLE BASE (2) and
ADAPTER (1) onto VALVE STEM (5).
2
WASHER
(PORCELIAN
CROSS
HANDLE ONLY)
Check alignment, if not satisfactory
1
aligned;
Push out ADAPTER (1) carefully.
5
Turn ADAPTER (1) either 45˚ or 90˚
so that male square on ADAPTER
(1) catches different female square
in HANDLE BASE (2).
Secure HANDLE BASE (2) and METAL
CROSS (6) or PORCELAIN CROSS (7) with HANDLE SCREW (3).
Push INDEX CAP (4) in hole of METAL CROSS (6) or
PORCELAIN CROSS (7).
Push INDEX CAP (4) in hole of LEVER BALL (6).
11
INSTALL HANDLES (Cross)
Turn VALVE into OFF position.
1
5
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
3
Remove AERATOR (3).
1
Operate both HANDLES (1) to flush water
lines thoroughly.
Replace AERATOR (3).
4
12
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (5) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
WASTE
OUTLET
2
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
COLD
“P” TRAP
HOT
13
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER.DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
14
2
1
2
SERVICE
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Remove IINDEX (1) and HANDLE SCREW (2).
Pull HANDLE (3) off.
Remove ADAPTER (4).
Remove SPRING CLIP (5).
Lift STOP WASHER (6), turn 90˚ and replace.
Replace SPRING CLIP (5).
Replace ADAPTER (4), HANDLE (2),
SCREW (2), and INDEX (1).
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
4
3
90˚
7
5
U S 6 0 4 0 4 R e v. 1 . 3
4
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
Fig. A.
Fig. B. Fig. C.
CAM
1
DOWN
1
RE-ATTACH
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
Fig. F.
REMOVE
CAM CAP
U S 6 0 4 0 4 R ev. 1 . 3
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
LOGO
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
LOGO
180˚
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
FRONT OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
CAM
INSTALL CAM
Fig. K.
INSTALL
CAM CAP
U S 6 0 4 0 4 R ev. 1 . 3
6
Spread Lavatory Faucet
with Pop-up Drain
013311-YYY0A
INDEX CAP (SET)
013307-YYY0A
METAL CROSS HANDLE
MODEL NUMBERS
918428-0070A
HANDLE SCREW
7871 SERIES
7881 SERIES
M962542-YYY0A
LIFT ROD & KNOB
042692-0070A
PORCELAIN
CROSS
HANDLE
918428-0070A
HANDLE
SCREW
M962461-YYY0A
LIFT ROD & KNOB
908501-YYY0A
CROSS HANDLE BASE
060353-YYY0A
PORCELAIN
LEVER HANDLE
021470-YYY0A
INDEX CAP
013306-YYY0A
AERATOR
918428-0070A
HANDLE SCREW
M961719-YYY0A
SPOUT
ESCUTCHEON
KIT
M961733-0070A
SPOUT MTG KIT
916503-YYY0A
LEVER HANDLE
BASE
060354-YYY0A
METAL
LEVER HANDLE
066070-YYY0A
AERATOR
M961733-0070A
SPOUT MTG KIT
923002-0070A
HANDLE ADAPTER
M961725-YYY0A
SPOUT KIT
7871 SERIES
M961724-YYY0A
SPOUT KIT
7881 SERIES
013312-YYY0A
VALVE
ESCUTCHEON KIT
994053-0070A
VALVE
M962544-YYY0A
STOPPER
ASSEMBLY
M906617-0070A
ATTACHMENT NUT
M964890-0070A
CABLE ASSEMBLY
M953006-0070A
TEE & HOSE KIT
M962457-YYY0A
FLANGE
ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M922872-0070A
CAM SEAT INSERT
024220-0070A
SUPPLY NUT
M962430-0070A
CAM ASSEMBLY
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
066116-YYY0A
DRAIN STOPPER
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
066118-0070A
PIVOT ROD KIT
066117-YYY0A
2" FLANGE KIT
051376-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
070847-0070A
CLIP
M913207-0070A
TAILPIECE INSERT
Replace the "YYY" with
appropriate finish code
CHROME
POLISHED BRASS
SATIN (PVD)/CHROME
VELVET
VELVET/BRASS
SATIN NICKEL
SATIN/BRASS
CHROME/BRASS
002
099
221
285
287
295
297
299
A919661-0020A
TAILPIECE
M962458-0070A
DRAIN MOUNTING KIT
M961711-0070A
TAILPIECE INSERT
HOT LINE FOR HELP
070532-0040A
TAILPIECE
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
POP-UP DRAIN ASSEMBLY
BEFORE 04/06
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
U S 6 0 4 0 4 R ev. 1 . 3
7