Download Teledyne Portable Pollution Emissions Monitor 9950 User's Manual

Transcript
TELEDYNE
ANALYTICAL INSTRUMENTS
MODEL
One System . . .
Multiple Solutions . . .
Reliable Combustion and Pollution Monitoring in a Compact, Affordable Package
PORTABLE
POLLUTION EMISSIONS MONITOR
Model 9950
Portable Pollution Emissions Monitor
Reliable Combustion and Pollution
Monitoring in an Affordable Package
Model 9950 is a full-featured monitor offering fast,
cost-effective analysis of stack gas emissions. As many
as five parameters can be displayed at once, allowing
the operator to optimize combustion efficiency while
minimizing pollution. Teledyne incorporates advanced
microprocessor technology which provides a menudriven interface with all functions through front panel
controls and a large LCD display. In other words, we put
all the best features in one affordable package.
High accuracy is expected of any pollution
emissions monitor, but the 9950 accomplishes the task
in record time. This model provides an emissions
analysis and a hard copy printout in less than 5 minutes
with an accuracy of better than +/-3% of full scale.
Self-Contained and Easy to Operate
Light weight and compact with both an internal
battery and AC powered operation, the Model 9950 is
housed in a rugged aluminum case, tough enough for
the worst you have to offer. Completely portable, the
monitor is ideal for spot-checking in even the most
difficult environments. Typical applications include
boilers, furnaces, fireboxes and compressor engines,
and other stationary combustion processes.
Features:
❍ Analyzes O2, CO, SO2, NO, NO2, and stack
temperature - Calculates CO2, combustion
efficiency and pollutants emitted.
❍ Long-term stability and performance
❍ Microprocessor-based design
Precise Measurement of Combustion
Efficiency and Pollution Levels
Enter the fuel type to be measured by means of the
5-button panel and take a sample. Model 9950
automatically calculates the net combustion efficiency
making it easy for you to fine-tune the combustion
process and reduce unwanted emissions.
SO2 and NOx (NO + NO2 ) measurements provide
valuable data about combustion process performance
versus emission standards. In addition, the Model 9950
calculates the concentration of CO2 for any given fuel to
assist with adjustments.
Hard copy printouts of emissions concentrations
are available at the push of a button to document
compliance with various state and federal regulations.
❍ RS-232 serial interface
❍ Logical, menu-driven LCD graphic readout with
5 button front panel
❍ Internal battery or AC-powered operation
❍ Lightweight (27 pounds) and compact
❍ Heavy-duty, aluminum case
❍ Integral sample pumps
❍ Printer for emissions results
❍ 99-test memory
Easy Calibration & Test Data Storage
An auto-zero feature for the gas sensors takes
even more of the work out of your hands. Span settings
are carried out by means of front-panel control switches,
and keypad controls remain functional during setup,
allowing the operator to select any analysis parameters
or fuels as necessary. All settings remain in memory –
even when power is turned off – and will be stored until
amended by the user or the analyzer is deliberately "cold
started" to clear the memory.
The 9950 stores up to 99 individual tests (including
a complete set of measurements and boiler ID number)
which are maintained in a non-volatile memory and can
be retrieved for printout for downloading via the RS-232
serial port.
Sample Integrity is Never in Question
Model 9950 accomplishes sample conditioning
through a fully integrated handling system capable of
delivering stack gas to the analyzer without
compromising integrity. A stainless steel probe is
connected to the monitor by a flexible hose. A highefficiency vane pump draws the sample through the
probe and into a coalescing filter where particulates and
condensates are removed prior to analysis, assuring you
the highest accuracy possible. Water and particulate
matter are automatically pumped from the system.
Measured Parameters
Range*
Resolution
Accuracy
Oxygen (02)
0-25%
Electrochemical cell
Expected Life - 24-36 months
0.1%
+/-1%FS**
Carbon Monoxide
0-2000 ppm
Electrochemical cell
Expected Life - 24-36 months
1ppm*
+/-3%FS**
0-1000 ppm
Sulfur Dioxide (SO2)
Electrochemical cell
Expected Life - 24-36 months
1ppm*
+/-3%FS**
Nitric Oxide (NO)
0-2000 ppm
Electrochemical cell
Expected Life - 24-36 months
1ppm*
+/-3%FS**
Nitrogen Dioxide (NO2)
0-200 ppm
Electrochemical cell
Expected Life - 24-36 months
1ppm*
+/-3%FS**
Combustion Gas Temperature 0-850°C
K-type thermocouple
continuous
0-1200°C
intermittent
1°C
Ambient Temperature
1°C
0-50°C
1°C
(for less than 85% relative humidity)
0-40°C
(for 85% relative humidity-printer specifications)
Calculations
Range
Resolution
Accuracy
Carbon Dioxide (CO2)
0-20%
0.1%
+/-5%
Combustion Efficiency
0-100%
0.1%
Pollutant Emissions
0-9.999
0.001
lbs / million BTU
varies with application
+/-3%
* Please contact factory regarding non-standard ranges.
** At constant temperature once thermal equilibrium is achieved.
Options
SO2
NO
Probe and hose lengths
NOTE: longer lengths may not fit within case
Selected optimal ranges for the
CO / SO2 / NO / NO2 analysis are available
Remote display unit
O2
CO
L IN
ICA PEM
T
LY 9950
NA
E A ODEL
N
Y
M
ED
NO2
TEL
/98
2:
M
18 P
1/19
S
NT
ME
U
STR
IL
%
2O
.: # .: 70.1 ˚F
O
20
L N . EFF
8
E
FU BU MP.:
M
CO CK TE %
4.8 M
STA
P
O2: 987 P
%
:
5
.
O
C : 11 PM
2
PM
2P M
CO
3P
P
:
2):
NO : 1 P +NO
2
(NO
NO
X 1 PPM
O
N :
SO2
Real Technical Support
Specifications
As with any Teledyne product, you are one phone call
away from assistance with Model 9950. Whether in the
field or in the factory, a Teledyne Field Service Engineer
can assist with questions. Simply refer to the phone
numbers below for a Teledyne representative in your
area. Also, the instruction manual included with every
product offers quick reference for any process required of
the 9950. Clear, easy-to-read instructions with charts and
illustrations guide every step of the process to assure
accurate results and maximum safety.
Operating Temperature:
0-50°C; not to be used for more than 8
hours above 40°C
Digital Outputs:
Measured and stored data; RS-232 serial
interface, 1200 baud rate; 8 data bits;
1 stop bit; no parity
User Interface:
LCD; 30 characters wide by 7 lines;
5 soft keys; menu-driven program
Fuels:
15 User selectable
Natural gas
No. 2 fuel oil
No. 4 fuel oil
No. 6 fuel oil
Anthracite coal
Bituminous coal
Lignite coal
Kerosene
Propane
Butane
Wood chips - 50%H2O
Wood chips - 0% H2O
Coke oven gas
Blast furnace gas
Sewer gas
Power Requirements:
AC power mains and/or internal battery;
90-255 VAC at 50-60 Hz; rechargeable
12VDC battery; low battery indicator on
LCD display (8 hours on one charge)
Data Logging:
Archives up to 99 tests
Probe:
316 stainless steel; K-type thermocouple;
3/8" OD; 13" / 33cm insertion length;
10' / 3m neoprene hose
Printer:
2-1/4" / 5.7cm wide thermal paper, line
feed button
Packaging:
Suitcase-type, heavy-duty aluminum
case. Case holds probe, 10' / 3m hose
and instruction manual.
Dimensions:
18" W x 13"D x 6" H
45.7cm W x 33cm D x 15.25cm H
Weight (approx.):
27 lbs. / 12.27 kg
Teledyne Analytical Instruments
World Leader in Gas and Liquid Analysis
With over 40 years of analytical instrument experience,
Teledyne supplies sensors, custom engineered
analyzers and complete monitoring systems to satisfy
unique applications.
Optional remote display unit available
TELEDYNE
ANALYTICAL INSTRUMENTS
A Teledyne Technologies Company
16830 Chestnut Street
City of Industry, California 91748, USA
TEL: 626-934-1500
FAX: 626-934-1651
TOLL FREE: 888-789-8168
Visit Our Web Site at:
www.teledyne-ai.com
© 1998 Teledyne Analytical Instruments, A Teledyne Technologies Company.
All rights reserved. Printed in the USA.
5/98LD
Regional Office
Tokyo, Japan ..............................................81-33-239-9090
Warranty
Instrument is warranted for 1 year against defects in material
or workmanship
NOTE: Specifications and features will vary with application. The above are
established and validated during design, but are not to be construed as test
criteria for every product. All specifications and features are subject to change
without notice.