Download Tecumseh AJA2423YAADC Performance Data Sheet
Transcript
June 12, 2013 Revision: A Celseon® Air Cooled Condensing Unit Model: AJA2423YAAD* BoM: 2G201-** R-134a Line Connection* Pumpdown Air Suction Liquid 90 F 90% SCFM AJA2423YAADA 3/8” S 1/4” S N/A AJA2423YAADG 3/8” S 3/8” S 2.5 lbs AJA2423YAADH 3/8” S 3/8” S N/A AJA2423YAADK 3/8” S 1/4” S 15.0 14.0 11.1 11.7 185 AJA2423YAADC 3/8” S 3/8” S 2.5 lbs AJA2423YAADS 3/8” S 3/8” S N/A AJA2423YAADJ 3/8” S 3/8” S 2.5 lbs AJA2423YAADP 3/8” S 3/8” S 2.5 lbs * F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting Factory charge: 20 PSIG Nitrogen – MUST BE EVACUATED Model L Dimensions, inches W H 1/2 HP CH Oil Ch Oz. 26 Gr. Wt. Lbs. 62 64 62 62 64 62 64 64 Ambient Temperatures Evaporator T, 80°F 90°F °F PSIG BTUH Watts Cond T BTUH Watts -30 *9.8” 1177 389 -25 *6.9” 1575 459 90 735 93 1124 -20 *3.7” 1980 -15 0.1 2390 528 95 598 99 -10 1.9 -5 4.2 2801 668 3209 739 0 6.5 3611 5 9.0 10 11.9 100°F 110°F Cond T BTUH Watts Cond T BTUH Watts Cond T 311 97 321 233 104 217 154 111 387 100 701 316 107 307 244 114 1520 464 103 1088 399 110 685 335 117 1920 540 106 1479 483 113 1066 425 120 102 2321 618 109 1870 567 116 1447 516 123 106 2719 695 113 2257 651 120 1823 608 127 810 110 3110 773 117 2637 736 124 2192 699 131 4002 881 114 3489 851 121 3004 821 128 2548 791 135 4376 953 118 3852 930 125 3355 907 132 2886 884 139 60 Hz Performance Return gas temp. 40F, 5F sub cooling Note: * = Inches of Mercury below 1 Atmosphere June 12, 2013 Revision: A Specifications/ Parts: Unit Model Unit Bill of Material Refrigeration Range Design Pressure Low Design Pressure High Nominal Volts-Hz-Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size (amps) AJA2423YAADA 2G201-09 -40° F to +10° F 150 235 115-60-1 103 to 127 9.5 15 Compressor Model Comp. Bill of Material Compressor RLA/LRA Overload Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating AJA2419YXA AJ135AT-434-P2 7.3/68 External 820ARR3B92 85PR370E36 15MFD 370V(M) VDE 85PS110A15 270-324 MFD 110V Fan Motor Fan Motor RLA Fan Blade Fan Shroud/Guard Combo Condenser 810-10001 .38 515-10002 707-00004 506-10004 Unit Drawing Wiring Diagram DGU1971-03 91266-02 Replacement Kit: Relay Replacement Kit: O/L K71-13 K90-30 Unit Model Unit Bill of Material Receiver Tank Liquid Valve Suction Valve AJA2423YAADG 2G201-19 510-10000 56630 56630 Unit Model Unit Bill of Material Liquid Valve Suction Valve AJA2423YAADH 2G201-29 56630 56630 Unit Model Unit Bill of Material Power Cord AJA2423YAADK 2G201-39 85106-14 Unit Model Unit Bill of Material Receiver Tank Liquid Valve Suction Valve Power Cord AJA2423YAADC 2G201-59 510-10000 56630 56630 85106-14 Unit Model Unit Bill of Material Liquid Valve Suction Valve Power Cord AJA2423YAADS 2G201-69 56630 56630 85106-14 Unit Model Unit Bill of Material Receiver Tank Liquid Valve Suction Valve Filter Drier Sight Glass AJA2423YAADJ 2G201-79 510-10000 56630 56630 71116 70084 Unit Model Unit Bill of Material Receiver Tank Liquid Valve Suction Valve Power Cord Filter Drier Sight Glass AJA2423YAADP 2G201-89 510-10000 56630 56630 85106-14 71116 70084 June 12, 2013 Revision: A Electrical Diagram Page 3