Download TDK ZACT-ME Series User's Manual
Transcript
(1/2) Conformity to RoHS Directive EMC Filters for AC Power Line For Triple-phase, Large-size Box Cased ZACT-ME Series FEATURES • While reducing the filter size, the highly efficient thermal design allows the handling of large currents with high attenuation. • They are highly effective at preventing both the radiation and penetration of EMC noise. The parts are, therefore, highly immune to externally generated noise and do not, themselves, serve as sources of radiated noise • For the frequency band set by CISPR, attenuation is shown for both differential mode and common mode noise components. • Can withstand voltages of AC.1250V between the lines, and AC. 2000V between the line to ground. • It is a product conforming to RoHS directive. SAFETY STANDARDS Standard and standard No. U.S.A. Canada Part No. Europe CSA UL UL1283 NEMKO CSA C22.2 No.8 LR76849C ZACT2230-ME EN60939 P08208997 APPLICATIONS Computers, HDDs, electronic exchange devices, NC control devices, inverters for motor, etc. SHAPES AND DIMENSIONS K R1 R2 S1 S2 T1 T2 øG E I A H øH B J F C D Dimensions in mm Part No. A ZACT2230-ME 120 • Case: metal, terminal: stud B 200 C 115 D 260 E 100 F 220 øG M6 H 5.5 I 64 J 66 K 240 ELECTRICAL CHARACTERISTICS Part No. Rated voltage Eac(V) Rated current(A) Test voltage Eac(V)[Between terminal and case] Insulation resistance(MΩ) [DC. 500V, 1min/between terminal and case] Leakage current(mA)[250V • 60Hz] DC resistance(mΩ) Operating temperature range(°C)[Including self-temperature rise] With derating over(°C) Temperature rise(°C) Differential mode at 40dB Attenuation frequency range (MHz)[+5 to +35°C] Common mode at 40dB Weight(kg) ZACT2230-ME 250 30 2000 100min. 1max. 40max. –25 to +85 45 35max. 0.15 to 10 0.15 to 10 5 • Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. • All specifications are subject to change without notice. 005-01 / 20090226 / e9111_zact_me.fm (2/2) TYPICAL ELECTRICAL CHARACTERISTICS ATTENUATION vs. FREQUENCY CHARACTERISTICS ZACT2230-ME PULSE ATTENUATION CHARACTERISTICS 100 Differential mode Attenuation (dB) 80 Differential mode 60 Common mode 40 Output voltage (V) 100 20 0 80 60 Pulse width: 1µs 40 0.3 1 3 10 Frequency (MHz) 30 Pulse width: 0.2µs 20 0 0.1 Pulse width: 0.6µs 0 500 1000 Input voltage (V) 1500 2000 100 CIRCUIT DIAGRAM R2 R R1 T1 R: Bleeder resistor S2 R R S1 T2 Case GND CAUTIONS • When there is a danger of a high energy pulse voltage (over 2kV for over 1µs), use a surge absorbing element such as a varistor, or arrestor on the EMC filter power supply input side. • All specifications are subject to change without notice. 005-01 / 20090226 / e9111_zact_me.fm