Download TDK ZACT-ME Series User's Manual

Transcript
(1/2)
Conformity to RoHS Directive
EMC Filters for AC Power Line
For Triple-phase, Large-size Box Cased ZACT-ME Series
FEATURES
• While reducing the filter size, the highly efficient thermal design
allows the handling of large currents with high attenuation.
• They are highly effective at preventing both the radiation and
penetration of EMC noise. The parts are, therefore, highly
immune to externally generated noise and do not, themselves,
serve as sources of radiated noise
• For the frequency band set by CISPR, attenuation is shown for
both differential mode and common mode noise components.
• Can withstand voltages of AC.1250V between the lines, and AC.
2000V between the line to ground.
• It is a product conforming to RoHS directive.
SAFETY STANDARDS
Standard and standard No.
U.S.A.
Canada
Part No.
Europe
CSA
UL
UL1283
NEMKO
CSA C22.2 No.8
LR76849C
ZACT2230-ME
EN60939
P08208997
APPLICATIONS
Computers, HDDs, electronic exchange devices, NC control
devices, inverters for motor, etc.
SHAPES AND DIMENSIONS
K
R1
R2
S1
S2
T1
T2
øG
E
I
A
H
øH
B
J
F
C
D
Dimensions in mm
Part No.
A
ZACT2230-ME
120
• Case: metal, terminal: stud
B
200
C
115
D
260
E
100
F
220
øG
M6
H
5.5
I
64
J
66
K
240
ELECTRICAL CHARACTERISTICS
Part No.
Rated voltage Eac(V)
Rated current(A)
Test voltage Eac(V)[Between terminal and case]
Insulation resistance(MΩ)
[DC. 500V, 1min/between terminal and case]
Leakage current(mA)[250V • 60Hz]
DC resistance(mΩ)
Operating temperature range(°C)[Including self-temperature rise]
With derating over(°C)
Temperature rise(°C)
Differential mode at 40dB
Attenuation frequency range
(MHz)[+5 to +35°C]
Common mode at 40dB
Weight(kg)
ZACT2230-ME
250
30
2000
100min.
1max.
40max.
–25 to +85
45
35max.
0.15 to 10
0.15 to 10
5
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
005-01 / 20090226 / e9111_zact_me.fm
(2/2)
TYPICAL ELECTRICAL CHARACTERISTICS
ATTENUATION vs. FREQUENCY CHARACTERISTICS
ZACT2230-ME
PULSE ATTENUATION CHARACTERISTICS
100
Differential mode
Attenuation (dB)
80
Differential mode
60
Common mode
40
Output voltage (V)
100
20
0
80
60
Pulse width: 1µs
40
0.3
1
3
10
Frequency (MHz)
30
Pulse width: 0.2µs
20
0
0.1
Pulse width: 0.6µs
0
500
1000
Input voltage (V)
1500
2000
100
CIRCUIT DIAGRAM
R2
R
R1
T1
R: Bleeder resistor
S2
R
R
S1
T2
Case GND
CAUTIONS
• When there is a danger of a high energy pulse voltage (over 2kV
for over 1µs), use a surge absorbing element such as a varistor,
or arrestor on the EMC filter power supply input side.
• All specifications are subject to change without notice.
005-01 / 20090226 / e9111_zact_me.fm