Download TDK J Series JBW User's Manual
Transcript
(1/30) Conformity to RoHS Directive AC Input Single Output, General-Purpose, UL/C-UL/TÜV Approved J Series JBW(10 to 150W) FEATURES • Compact and low price. • Wide input voltage range. • Safety standards approved. • Corresponds to products with CE marking. • Full lineup of output power 10 to 150W • Open frame • Meets conducted noise standard FCC Class B. • Warranty period: 3 years • Specific bromine inflammable materials (PBDPEs, PBBs) are not included in use. • It is a product conforming to RoHS directive. APPLICATIONS Measuring equipment, robotics, automation equipment, information processing equipment, security systems, amusement equipment, etc. PRODUCT IDENTIFICATION SAFETY STANDARDS UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV), approved. EMC REGULATIONS • FCC Class-B, VCCI Class-B, EN-55011-B and EN55022-B meet. • Harmonic current requirement EN61000-3-2 meet(50 to 150W). JBW (1) 05 (2) – 2R0 (3) (1)Series name (2)Rated output voltage (3)Rated output current(R: Decimal point) PART NUMBERS AND RATINGS Output voltage (V) 5 12 15 24 10W Type Current(A) 2 0.9 0.7 0.5 Part No. JBW05-2R0 JBW12-0R9 JBW15-0R7 JBW24-0R5 15W Type Current(A) 3 1.3 1 0.7 Part No. JBW05-3R0 JBW12-1R3 JBW15-1R0 JBW24-0R7 30W Type Current(A) 6 2.5 2 1.3 Part No. JBW05-6R0 JBW12-2R5 JBW15-2R0 JBW24-1R3 Output voltage (V) 5 12 15 24 48 75W Type Current(A) 15 6.3 5.0 3.2 — Part No. JBW05-15R JBW12-6R3 JBW15-5R0 JBW24-3R2 — 100W Type Current(A) 20 8.5 6.7 4.3 — Part No. JBW05-20R JBW12-8R5 JBW15-6R7 JBW24-4R3 — 150W Type Current(A) 30 12.5 10 6.3 3.2 Part No. JBW05-30R JBW12-12R JBW15-10R JBW24-6R3 JBW48-3R2 50W Type Current(A) 10 4.3 3.5 2.1 Part No. JBW05-10R JBW12-4R3 JBW15-3R5 JBW24-2R1 • 3.3 and 48V models(75 to 150W type) are made to order. • Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (2/30) JBW10W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current∗ Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Fuse rating Surge current Leakage current Power factor Efficiency W V Hz A A A mA % % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Minimum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Parallel operation Series operation Output voltage external variable function Standards Safety standards Noise terminal voltage Input harmonics current requirement Constructions External dimensions mm Weight g Mounting method Case material JBW05-2R0 5V • 2A 10 JBW12-0R9 12V • 0.9A 10.8 JBW15-0R7 15V • 0.7A 10.5 JBW24-0R5 24V • 0.5A 12 85 to 265[Rating: 100 to 240]/110 to 370 47 to 440[Rating: 50 to 60](Single phase) 0.25typ./0.35max. [AC.100V]0.15typ./0.25max.[AC.240V] 2[AC.250V, built-in] 15typ.(20max.)[AC.100V]30typ.(40max.)[AC.240V] 1st surge current, cold start, reset after 1s minimum. 0.1typ./0.75max.[AC.100V, 60Hz]0.15typ./0.75max.[AC.240V, 60Hz] 0.6typ./0.45typ.[AC.100/240V] 71typ.[AC.100V] 78typ.[AC.100V] 79typ.[AC.100V] 82typ.[AC.100V] 71typ.[AC.240V] 79typ.[AC.240V] 80typ.[AC.240V] 83typ.[AC.240V] 5 12 15 Fixed Fixed Fixed 2 0.9 0.7 0 0 0 5.75min. 13.8min. 17.25min. 2.5min. 1.12min. 0.87min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +50°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80max. 120max. 120max. 120max. 150max. 150max. 700max.(200typ.)/700max.(200typ.) [AC.100/240V] 15typ/140typ [AC.100/240V] 24 Fixed 0.5 0 27.6min. 0.62min. 120max. 150max. No Zenor diode clamp method, output may latch up depending on the condition. Fold back type, automatic recovery. No No Impossible Inpossible No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. No 21× 36× 95[H× W× L] 50max. Can be attached to 1 side. No(PWB Material: CEM3) ∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range. • Optional input, output cable kits are available at a separate price. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (3/30) JBW10W Type SHAPES AND DIMENSIONS 2-ø3.4Mounting holes 95 21 7 5.2 Area For Spacer(ø6.0max.) 3max. 3.5 10 7 3.5 Solder Side TB1 TB2 + + _ _ 17.3 29±0.5 7 N JBW05-2R0 TDK 36 L Ser. No. LABEL 3.8 16.4 1.6 88±0.5 3.5 GND Pad Solder Side 7 Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION TB2 TB1 P3 L P2 N L 1 N 2 P4 6 5 + + _ _ P3 P2 3 P1 Japan Solderless Terminal Co., Ltd. Input Connector(TB1) VH Series Output Connector(TB2) XH Series LCE Input Connector(TB1) P101 Series Output Connector(TB2) P221 Series – P1 4 Connector made by + Power supply side connector Cable Side Housing Terminal B3P5-VH-B B4B-XH-2 VHR-5N XHP-4 SVH-21T-P1.1 SXH-001T-P0.6 P101-05-2/4 P221-04 H101-05 H221-04 T101 T221-01 Terminal No. 1 2 3 4 5 6 Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad Output terminal(–) Output terminal(+) Option Set Part No. 4EU20G054 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (4/30) JBW15W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current∗ Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Fuse rating Surge current Leakage current Power factor Efficiency W V Hz A A A mA % % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Minimum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Parallel operation Series operation Output voltage external variable function Standards Safety standards Noise terminal voltage Input harmonics current requirement Constructions External dimensions mm Weight g Mounting method Case material JBW05-3R0 5V • 3A 15 JBW12-1R3 12V • 1.3A 15.6 JBW15-1R0 15V • 1.0A 15 JAW24-0R7 24V • 0.7A 16.8 85 to 265[Rating: 100 to 240]/110 to 370 47 to 440[Rating: 50 to 60](Single phase) 0.36typ./0.43max.[AC.100V]0.2typ./0.24max.[AC.240V] 2[AC.250V, built-in] 15typ./19.5max.[AC.100V]30typ./41max.[AC.240V] 1st surge current, cold start, reset after 1s minimum. 0.2typ./0.75max.[AC.100V, 60Hz]0.3typ./0.75max.[AC.240V, 60Hz] 0.6typ./0.45typ.[AC.100/240V] 72typ.[AC.100V] 76typ.[AC.100V] 76typ.[AC.100V] 78typ.[AC.100V] 72typ.[AC.240V] 74typ.[AC.240V] 74typ.[AC.240V] 76typ.[AC.240V] 5 12 15 24 Fixed Fixed Fixed Fixed 3 1.3 1 0.7 0 0 0 0 5.75min. 13.8min. 17.25min. 27.6min. 3.15min. 1.37min. 1.05min. 0.74min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +50°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80max. 120max. 120max. 120max. 120max. 150max. 150max. 150max. 200max.(25typ.)/100max.(25typ.)[AC.100/240V] 200max.(40typ.)/100max.(40typ.)[AC.100/240V] 13typ./150typ. [AC.100/240V] No Zenor diode clamp method, output may latch up depending on the condition. Rectangular type, automatic recovery. No No Impossible Impossible No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. No 22.6× 50× 95[H× W× L] 80max. Can be attached to 1 side. No(PWB Material: CEM3) ∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range. • Optional input, output cable kits are available at a separate price. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (5/30) JBW15W Type SHAPES AND DIMENSIONS 22.6 95 4-ø3.4Mounting holes + + _ _ 50 TB3 3.5 7 7 N 43±0.5 TB1 JBW05-3R0 3.8 TDK 5.2 L 3max. 3.5 28 23.7 88±0.5 Ser. No. LABEL 7 18.5 1.6 7 Area For Spacer (ø6.0max.) GND Pad Solder Side Solder Side 3 Places Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION TB3 TB1 P3 L P2 N P1 P4 L 1 N 2 6 5 + + _ _ + P3 P2 – P1 3 Terminal No. 1 2 3 4 5 6 Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad Output terminal(–) Output terminal(+) Option Set Part No. 4EU20G054 4 Connector made by Japan Solderless Terminal Co., Ltd. Input Connector(TB1) VH Series Output Connector(TB3) XH Series LCE Input Connector(TB1) P101 Series Output Connector(TB3) P221 Series Power supply side connector Cable Side Housing Terminal B3P5-VH-B B4B-XH-2 VHR-5N XHP-4 SVH-21T-P1.1 SXH-001T-P0.6 P101-05-2/4 P221-04 H101-05 H221-04 T101 T221-01 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (6/30) JBW30W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current∗ Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Fuse rating Surge current Leakage current Power factor Efficiency W V Hz A A A mA % % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Minimum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Parallel operation Series operation Output voltage external variable function Standards Safety standards Noise terminal voltage Input harmonics current requirement Constructions External dimensions mm Weight g Mounting method Case material JBW05-6R0 5V • 6A 30 JBW12-2R5 12V • 2.5A 30 JBW15-2R0 15V • 2A 30 JAW24-1R3 24V • 1.3A 31.2 85 to 265[Rating: 100 to 240]/110 to 370 47 to 440[Rating: 50 to 60](Single phase) 0.65typ./0.86max.[AC.100V]0.35typ./0.48max.[AC.240V] 2[AC.250V, built-in] 15typ./30max.[AC.100V]30typ./60max.[AC.240V] 1st surge current, cold start, reset after 1s minimum. 0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz] 0.6typ./0.45typ.[AC.100/240V] 75typ.[AC.100V] 78typ.[AC.100V] 79typ.[AC.100V] 80typ.[AC.100V] 77typ.[AC.240V] 79typ.[AC.240V] 80typ.[AC.240V] 81typ.[AC.240V] 5 12 15 Fixed Fixed Fixed 6 2.5 2 0 0 0 5.6min. 13.3min. 16.6min. 6.3min. 2.7min. 2.1min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 2max.[Ambient temperature: –10 to +50°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80max. 120max. 120max. 120max. 150max. 150max. 650max.(350typ.)/320max.(130typ.)[AC.100/240V] 20typ./160typ.[AC.100/240V] 24 Fixed 1.3 0 26.5min. 1.4min. 120max. 150max. No Voltage shut-down type. Rectangular type(Winker operation), automatic recovery. No No Impossible Impossible No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. No 26× 55× 122[H× W× L] 150max. Can be attached to 1 side. No(PWB Material: CEM3) ∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range. • Optional input, output cable kits are available at a separate price. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (7/30) JBW30W Type SHAPES AND DIMENSIONS 4-ø3.4Mounting holes 122 GND Pad 2 Places Solder Side 26 112±0.5 6.5 3max. 30 TB1 45±0.5 55 TB2 _ _ + + 8 8 L 6.6 JBW05-6R0 TDK N 8 8 Ser. No. LABEL 5 16 5 21.4 1.6 Area For Spacer (ø6.0max.) Solder Side 2 Places Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION 4 TB1 P1 L P2 N P3 4 TB2 3 P1 N 2 P2 L 1 5 6 Connector made by Japan Solderless Terminal Co., Ltd. Input Connector(TB1) VH Series Output Connector(TB2) VH Series LCE Input Connector(TB1) P101 Series Output Connector(TB2) P101 Series _ _ + + Power supply side connector Cable Side Housing Terminal B3P5-VH-B B4P-VH-B VHR-5N VHR-4N SVH-21T-P1.1 SVH-21T-P1.1 P101-05-2/4 P101-04 H101-05 H101-04 T101 T101 P3 P4 – + Terminal No. 1 2 3 4 5 6 Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad Output terminal(–) Output terminal(+) Option Set Part No. 4EU20G057 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (8/30) JBW50W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current∗1 Maximum output power W Input conditions Input voltage Eac/Edc∗2 V Input frequency Hz Input current A Fuse rating A Surge current A Leakage current mA Power factor % Efficiency % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Minimum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Parallel operation Series operation Output voltage external variable function Standards Safety standards Noise terminal voltage Input harmonics current requirement Constructions External dimensions mm Weight g Mounting method Case material JBW05-10R 5V • 10A 50 JBW12-4R3 12V • 4.3A 51.6 JBW15-3R5 15V • 3.5A 52.5 85 to 265[Rating: 100 to 240]/120 to 375 47 to 66[Rating: 50 to 60](Single phase) 0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V] 3.15[AC.250V, built-in] 15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start 0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz] 0.99typ./0.93typ.[AC.100/240V] 77typ.[AC.100V] 80typ.[AC.100V] 80typ.[AC.100V] 79typ.[AC.240V] 81typ.[AC.240V] 81typ.[AC.240V] 5 12 15 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 10 4.3 3.5 0 0 0 5.75 to 6.9 13.8 to 16.8 17.2 to 21 10.5min. 5.4min. 4.4min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +50°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80max. 120max. 120max. 120max. 150max. 150max. 500max.(400typ.)/500max.(400typ.) [AC.100/240V] 20typ./20typ. [AC.100/240V] JBW24-2R1 24V • 2.1A 50.4 81typ.[AC.100V] 83typ.[AC.240V] 24 21.6 to 26.4 2.1 0 27.6 to 33.6 2.7min. 120max. 150max. No Voltage shut-down type. Rectangular type, automatic recovery. No No Impossible Possible No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. EN61000-3-2 meet. 26× 55× 190[H× W× L] 220max. Can be attached to 1 side. No(PWB Material: CEM3) ∗1 Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range. note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the input voltage. • Optional input, output cable kits are available at a separate price. ∗2 Please • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (9/30) JBW50W Type SHAPES AND DIMENSIONS GND Pad 2 Places Solder Side 4-ø4 Mounting holes 190 26 35.7 180±0.5 3max. 12.1 5 5 N 45±0.5 Ser. No. LABEL TB1 _ _ + + 47.7 5.5 8 5 8 8 7.1 17.2 55 TB2 L 5 21.4 1.6 8 Area For Spacer (ø6max.) Solder Side 2 Places RATING LABEL JBW05-10R TDK Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION 4 TB1 4 7 TB2 3 P4 P3 N P2 N P1 L L 2 1 5 6 _ _ + + – P3 P2 P1 + Terminal No. 1 2 3 4 5 6 7 Connector made by Japan Solderless Terminal Co., Ltd. Input Connector(TB1) VH Series Output Connector(TB2) VH Series LCE Input Connector(TB1) P101 Series Output Connector(TB2) P101 Series Power supply side connector Cable Side Housing Terminal B3P5-VH-B B4P-VH-B VHR-5N VHR-4N SVH-21T-P1.1 SVH-21T-P1.1 P101-05-2/4 P101-04 H101-05 H101-04 T101 T101 Option Set Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad Output terminal(–) Output terminal(+) Output voltage variable volume Part No. 4EU20G057 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (10/30) JBW75W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Fuse rating Surge current Leakage current Power factor Efficiency W V Hz A A A mA % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Standards Safety standards Noise terminal voltage Input harmonics current requirement CE marking Constructions External dimensions mm Weight g Mounting method Case material JBW05-15R 5V • 15A 75 JBW12-6R3 12V • 6.3A 75.6 85 to 265[Rating: 100-240]/120 to 370 47 to 66 1.6/0.8max.[100-240V] 3.15 30/60max.[100-240V] 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)] 0.99/0.95typ.[100-240V] 75/77typ. 78/80typ. [100-240V] [100-240V] JBW15-5R0 15V • 5.0A 75 JBW24-3R2 24V • 3.2A 76.8 79/81typ. [100-240V] 82/84typ. [100-240V] 5 12 15 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 15 6.3 5.0 5.75 to 6.9 13.8 to 16.8 17.2 to 21 15.8min. 6.6min. 5.2min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +60°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80 120 120 120 150 150 500max.(400typ.)/250max.(200typ.)[AC.100/240V] 20typ.[100-240V] 24 21.6 to 26.4 3.2(Peak4.2) 27.6 to 33.6 4.4min. 120 150 No Voltage shut-down type(Latch). Rectangular type, automatic recovery. No No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. EN61000-3-2 Planned compliance. 32× 55× 222[H× W× L] 290max. Can be attached to 1 side. CEM3 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (11/30) JBW75W Type SHAPES AND DIMENSIONS 29 222 5 212±0.5 1.6 5 3max. 5 4-ø3.5 (4.5) CP1 CP2 (25.9) 9max. 5 6 (50.9) 1 (5.3) (43.2) 1 (33) 3 45±0.5 55 5 (45.9) 9max. Area for spacer(ø6max.) Solder Side(2 Places) Ground pattern area(ø6max.) Solder Side(2 Places) Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION CP2 CP1 P1 L P1 P3 N 5 P5 3 CP1 · Japan Solderless Terminal Co., Ltd. VH Series B3P5-VH-B P2 1 2 CP2 4 3 5 6 1 – P3 P4 P5 + P6 · Japan Solderless Terminal Co., Ltd. VH Series B6P-VH-B Connector made by Japan Solderless Terminal Co., Ltd. Input Connector(CP1)VH Series Output Connector(CP2)VH Series Power supply side connector Cable Side Housing Terminal B3P5-VH-B B6P-VH-B VHR-5N VHR-6N SVH-21T-P1.1 SVH-21T-P1.1 Option Set Part No. 4EU20G085 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (12/30) JBW100W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Fuse rating Surge current Leakage current Power factor Efficiency W V Hz A A A mA % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Standards Safety standards Noise terminal voltage Input harmonics current requirement CE marking Constructions External dimensions mm Weight g Mounting method Case material JBW05-20R 5V • 20A 100 JBW12-8R5 12V • 8.5A 102 85 to 265[Rating: 100-240]/120 to 370 47 to 66 1.8/1.0max.[100-240V] 5 30/60max.[100-240V] 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)] 0.99/0.95typ.[100-240V] 78/80typ. 80/82typ. [100-240V] [100-240V] JBW15-6R7 15V • 6.7A 100.5 JBW24-4R3 24V • 4.3A 103.2 80/82typ. [100-240V] 82/85typ. [100-240V] 5 12 15 ±10% ±10% ±10% 20 8.5 6.7 5.75 to 6.9 13.8 to 16.8 17.2 to 21 21.0min. 10.6min. 8.38min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +60°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80 120 120 120 150 150 500max.(400typ.)/500max.(300typ.)[AC.100/240V] 20typ.[100-240V] 24 ±10% 4.3(Peak5) 27.6 to 33.6 5.38min. 120 150 No Voltage shut-down type(Latch). Rectangular type, automatic recovery. No No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. EN61000-3-2 Planned compliance. 35× 62× 222[H× W× L] 400max. Can be attached to 1 side. FR4 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (13/30) JBW100W Type SHAPES AND DIMENSIONS 222 212±0.5 Input connector 32 1.6 Output voltage adjustment trimmer 3max. 9 5.0 CP2 3 CP1 5 9max. 1 (51.5) 5 (4.7) 42.0 (17.9) 62 52±0.5 (5.8) 1 8 Output voltage connector 9max. Area for spacer(ø6max.) Solder Side(3 Places) (32.7) Ground pattern area(ø6max.) Solder Side(1 Place) Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION CP2 4 P1 7 5 3 1 3 2 CP1 1 P3 1 5 P5 6 L P6 8 P3 N P7 P5 Japan Solderless Terminal Co., Ltd. Input Connector(CP1)VH Series Output Connector(CP2)VH Series + Terminal No. 1 2 3 4 5 6 7 Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad Output terminal(–) Output terminal(+) Output voltage setting trim(+) P8 · Japan Solderless Terminal Co., Ltd. VH Series B8P-VH-B · Japan Solderless Terminal Co., Ltd. VH Series B3P5-VH-B Connector made by – P4 CP2 CP1 P1 P2 Power supply side connector Cable Side Housing Terminal B3P5-VH-B B8P-VH-B VHR-5N VHR-8N SVH-21T-P1.1 SVH-21T-P1.1 Option Set Part No. 4EU20G056 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (14/30) JBW150W Type SPECIFICATIONS AND STANDARDS Part No. Rated output voltage and current∗ Maximum output power Input conditions Input voltage Eac/Edc Input frequency Input current Surge current Leakage current Power factor Efficiency W V Hz A A mA % Output characteristics Output voltage Edc V Voltage variable range Edc V Maximum output current A Overvoltage threshold Edc V Overcurrent threshold A Source effect % Load effect % Voltage Temperature effect % stability Drift(Time effect) % Recovery % Ripple Ep-p mV Ripple noise Ep-p mV Start up time ms Hold up time ms Auxiliary functions Indicator display Overvoltage protection Overcurrent protection Remote ON-OFF Remote sensing Standards Safety standards Noise terminal voltage Input harmonics current requirement CE marking Constructions External dimensions mm Weight g Mounting method Case metal ∗ JBW05-30R 5V • 30A 150 JBW12-12R 12V • 12A 150 JBW15-10R 15V • 10A 150 85 to 265[Rating: 100-240]/120 to 370 47 to 66 2.7/1.5max.[100-240V] 30/60max.[100-240V] 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)] 0.99/0.95typ.[100-240V] 78/80typ. 81/83typ. 81/83typ. [100-240V] [100-240V] [100-240V] JBW24-6R3 24V • 6.3A 151.2 JBW48-3R2 48V • 3.2A 153.6 82/84typ. [100-240V] 82/84typ. [100-240V] 5 12 15 24 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 30 12.5 10 6.3(Peak7.5) 5.75 to 6.9 13.8 to 16.8 17.2 to 21 27.6 to 33.6 31.5min. 15.7min. 12.5min. 7.87min. 0.4max.[Within the input voltage range] 0.8max.[0 to 100% load] 1max.[Ambient temperature: –10 to +60°C] 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] ±4max.[50 to 100% sudden load change] 80max. 120max. 120max. 120max. 120max. 150max. 150max. 150max. 500max.(400typ.)/500max.(300typ.)[AC.100/240V] 25/35typ.[AC.100/240V] 48 43.2 to 52.8 3.2 55.2 to 67.2 3.36min. 150max. 350max. No Voltage shut-down type(Latch). Rectangular type, automatic recovery. No No UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved. FCC-B, VCCI-B, EN55011-B, EN55022-B meet. EN61000-3-2 Meet. 40× 75× 222[H× W× L] 550max. Can be attached to 1 side. FR4 Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (15/30) JBW150W Type SHAPES AND DIMENSIONS 222 37 (5) 212±0.5 5 (29.5) CP3 1 UP 7 1 CP2 (4) 6 5 (4) Input connector (47.2) 75 3max. 1 3 CP1 65±0.5 1.6 (32.7) (5) 5.0 9max. 9max. (4) Output voltage adjustment trimmer Area for spacer(ø6max.) Solder Side(3 Places) (27.9) Ground pattern area(ø6max.) Solder Side(1 Place) Dimensions in mm ±1mm : without specified dimensions TERMINAL DESIGNATION 4 1 5 3 1 3 2 CP1 1 CP3 5 7 1 CP1 P1 L P3 N CP2 6 6 · Japan Solderless Terminal Co., Ltd. VH Series B3P5-VH-B Connector made by Japan Solderless Terminal Co., Ltd. Input Connector(CP1)VH Series Output Connector(CP2)VH Series Output Connector(CP3)VH Series P1 P1 P2 P2 P3 P3 P4 7 P5 CP3 CP2 + P5 P4 P5 P6 P6 P7 · Japan Solderless Terminal Co., Ltd. VH Series B6P-VH-B – Terminal No. 1 2 3 4 5 6 7 Designations Input terminal(L) Input terminal(N) Frame ground terminal(G) Ground pad –Output terminal(–) +Output terminal(+) Output voltage setting trim(+) · Japan Solderless Terminal Co., Ltd. VH Series B7P-VH-B Power supply side connector Cable Side Housing Terminal B3P5-VH-B B6P-VH-B B7P-VH-B VHR-5N VHR-6N VHR-7N SVH-21T-P1.1 SVH-21T-P1.1 SVH-21T-P1.1 Option Set Part No. 4EU00G062 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (16/30) Characteristics, Functions, and Applications BLOCK DIAGRAMS JBW10W/15W/30W TYPES Input filter circuit L AC input N Input rectifier circuit Surge current limiting circuit Output rectifying and smoothing circuit Input smoothing circuit Overcurrent detection circuit Power switching circuit + DC OUT – Overvoltage protection Drive circuit PWM control circuit Output voltage control circuit JBW50W TYPE L AC input N Surge current limiting circuit Input filter circuit Input smoothing circuit Output rectifying and smoothing circuit Boost-up circuit PFC control circuit Overcurrent detection circuit + DC OUT – Power switching circuit Drive circuit Overvoltage detection circuit Control circuit Output voltage control circuit COMMON SPECIFICATIONS Temperature and humidity Operating(°C) Temperature range Operating available(°C) Storage(°C) Operating(%)RH Humidity range Storage(%)RH Vibration and shock 5 to 10Hz Vibration 10 to 200Hz Acceleration Shock Pulse duration Withstand voltage and insulation resistance Input terminal to ground terminal(G) Withstand voltage Input terminal to output terminal Output terminal to ground terminal(G) Input terminal to ground terminal(G) Insulation resistance Input terminal to output terminal Output terminal to ground terminal(G) –10 to +60 –20 to –10 –30 to +75 10 to 90[Maximum wet-bulb temperature: 35°C, without dewing] All amplitude 10mm[3 directions, each 1h] Acceleration 19.6m/s2 (2G)[3 directions, each 1h] 10 to 50W: 588m/s2 (60G)[3 directions, each 3 times]/75 to 150W: 588m/s2(60G)[Sine wave] 11±5ms Eac: 2kV, 1min[Normal temperature, normal humidity, cutout current 10mA] Eac: 3kV, 1min[Normal temperature, normal humidity, cutout current 10mA] Eac: 500V, 1min[Normal temperature, normal humidity, cutout current 10mA] Eac: 500V, 100MΩ min.[Normal temperature, normal humidity] • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (17/30) Characteristics, Functions, and Applications 10 to 50W TYPES OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS) 75 to 150W TYPES OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS) 75, 100W TYPES 80 100 70 60 80 Output power(%) Output power(%) 100 40 Available operating range (outside of warranty) 20 (E),(F) (C),(D) (A) 60 40 Available operating range (outside of warranty) 20 10 20 30 40 50 Ambient temperature(˚C) 60 71 0 –20 –10 INSTALLATIONS • Mounting the power supply at the four corners with metal spacers (2 corners for 10W models). • Maintain a min. 4mm clearance distance in order to satisfy insulation and high voltage safety requirements. • Lay an insulating sheet under the power supply in case a min. 8mm installation space cannot be secured between the PC board and the housing. • Provide a min. 4mm distance between heat sink or component surface and surrounding objects in order to cause a thermal convection. • Since components are mounted on the back (solder) side of the product, sufficient care should be taken when handling the power supply to protect the PC board from shock, vibration, torsion, etc. which can result in damage caused by cracked chip components. ; ;; 4mm min. Mounting screw dia.: 3mm 4mm min. + + 8mm min. 10 20 30 40 50 Ambient temperature(˚C) 100 60 50 40 Available operating range (outside of warranty) 20 0 –20 –10 0 10 20 30 40 50 Ambient temperature(˚C) 60 INSTALLATION DIRECTION (C) (B) (A) Standard installation Heat sink (E) IN Power supply 60 (E),(F) (C),(D) (A) 80 (D) 4mm min. 0 150W TYPE Output power(%) 0 Components –20 –10 (F) OUT UP Housing OUT IN Metal spacer ø6mm max. To install the power supply in a device, apply the standard installation direction (A) or (B). In case of an installation in other directions, please contact TDK. (A) (B) Component surface Component surface There are installation directions (B) to (F) as shown below in addition to the standard installation direction (A) for mounting the power supply on an apparatus. The installation (B), however, is inhibited because it will cause heat to be trapped inside the power supply. Derating of the output voltage and the ambient temperature for the installation directions (C) to (F) are not the same as for the direction (A). Please consult us if you need. The shaded portion indicates a side in which an output connector is arranged. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (18/30) Characteristics, Functions, and Applications RIPPLE NOISE MEASUREMENT CONDITIONS Output connector L Load + C1 C2 Output ripple and noise measurement point (20MHz) C1 : 100µF Electrolytic capacitor C2 : 0.1µF Film capacitor L : 150mm SERIES OPERATION (TO INCREASE OUTPUT VOLTAGE OR TO OBTAIN SEPARATE ±OUTPUT) When the output voltage of a single power supply is insufficient, several power supplies can be connected in series in order to obtain a higher voltage or separate ±outputs. If power supplies A and B in the illustration below are 5V each, a 10V output can be obtained in this connection. It should be noted that, however, the output current is limited to the lower rated current value of the power supplies A and B. There is no problem if the voltages of A and B are different from each other. D1 and D2 in the illustration designate diodes for preventing reverse voltage application. They are provided for preventing internal components of the power supply having the lower rated voltage from being damaged by an applied reverse voltage caused by a short circuit in the load or the like. Use diodes which meet the following requirements: Reverse withstanding voltage: Over twice that of the combined output voltage Forward current: Over twice that of the output current Forward voltage drop: As small as possible (e.g. Shottkey diode, etc.) INSULATION AND WITHSTAND VOLTAGE TESTS The insulation and withstand voltage tests may cause deterioration. Care must be taken for execution of the tests. The potential must be equal among input, output, and FG (frame ground) terminals. It is preferable to use testers that gently start up at the testON and automatically discharge charged energy at the test-OFF. Manual discharging after the tests should be through a resistor around 100kΩ to 1MΩ (Do not perform discharging at low impedance. It may cause deterioration.) In any case, take full countermeasures for electric-shock prevention. OTHER CONDITIONS • Unless conditions are otherwise specified in the specifications or standards, 25°C and rated input-output should be applied. SERIES CONNECTION FOR INCREASING OUTPUT VOLTAGE Power supply A + – D1 (A)∗ Power supply B Load + – D2 ∗ For obtaining separate ±outputs, (A) should be zero voltage. • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (19/30) Characteristics, Functions, and Applications AC.200V TYPE: INPUT CURRENT 0.5 0.20 0.4 0.16 170V 0.12 240V 265V 0.3 85V 100V 0.2 132V Input current(A) Input current(A) JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0 AC.100V TYPE: INPUT CURRENT 0.1 0 0.04 0 20 40 60 Load(%) 80 40 60 Load(%) 80 80 Efficiency(%) 132V 100V 85V 60 40 20 100 170V 200V 265V 60 40 20 0 20 40 60 Load (%) 80 0 100 AC.100V TYPE: POWER FACTOR 1.0 1.0 0.8 0.8 85V 100V 132V 0.6 0 20 40 60 Load (%) 80 100 AC.200V TYPE: POWER FACTOR 0.4 Power factor Power factor 20 100 80 0.6 170V 240V 265V 0.4 0.2 0.2 0.0 0 AC.200V TYPE: EFFICIENCY 100 Efficiency(%) 0 100 AC.100V TYPE: EFFICIENCY 0 0.08 0.0 0 20 40 60 Load (%) 80 100 AC.100V TYPE: SURGE CURRENT 0 20 40 60 Load (%) 80 100 AC.200V TYPE: SURGE CURRENT Vin=100V 11A Vin=240V 27.6A H : 5ms/Div V : 5A/Div Enlarged view H : 0.1ms/Div V : 5A/Div H : 5ms/Div V : 10A/Div Enlarged view H : 0.1ms/Div V : 10A/Div • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (20/30) Characteristics, Functions, and Applications JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0 AC.100/200V TYPE: –20°C START UP CHARACTERISTICS AC.100/200V TYPE: +60°C START UP CHARACTERISTICS AC.265V AC.265V AC.85V AC.85V H : 50ms/Div AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS H : 50ms/Div AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS Off Off 240V 170V 100V 100V 85V 85V H : 10ms/Div AC.100V/200V TYPE: –20°C OVERCURRENT CURVE H : 10ms/Div AC.100V/200V TYPE: +60°C OVERCURRENT CURVE 6 6 5 5 AC.85V 4 AC.132V 3 Output voltage(V) Output voltage(V) AC.85V AC.170V AC.265V 2 AC.265V AC.170V AC.132V 4 3 2 1 1 0 0 0 1 2 3 4 Load current(A) 5 6 0 1 2 3 4 Load current(A) 5 6 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (21/30) Characteristics, Functions, and Applications AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 40 40 35 35 30 30 25 25 Life(Years) Life(Years) JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0 AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 20 15 20 15 10 30˚C 10 5 40˚C 50˚C 60˚C 70˚C 100 5 0 20 40 60 Load(%) 80 AC.100V TYPE: HOLD UP TIME 0 20 40 60 Load(%) 80 40˚C 50˚C 60˚C 70˚C 100 AC.200V TYPE: HOLD UP TIME 10000 1000 1000 100 115V 100V 85V 10 Hold up time(ms) 10000 Hold up time(ms) 30˚C 240V 200V 170V 100 10 1 1 10 25 50 Load(%) 75 100 10 25 50 Load(%) 75 100 CONDUCTIVE NOISE EMISSION 80 [PEAK DATA] [dBµV] 70 60 VCCI-B(QP) 50 VCCI-B(AV) (FCC-B) 40 30 20 10 0 0.15 0.5 5 1 10 30 Frequency(MHz) • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (22/30) Characteristics, Functions, and Applications JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0 AC.100V TYPE: INPUT CURRENT AC.200V TYPE: INPUT CURRENT 0.5 0.25 170V 85V 100V 0.3 132V 0.2 0.20 Input current(A) Input current(A) 0.4 0.1 0 0 20 40 60 Load(%) 80 0 0 20 40 60 Load(%) 80 100 AC.200V TYPE: EFFICIENCY 100 80 80 132V 100V 85V 60 40 Efficiency(%) Efficiency(%) 0.10 100 100 20 170V 240V 265V 60 40 20 0 20 40 60 Load (%) 80 0 100 AC.100V TYPE: POWER FACTOR 1.0 1.0 0.8 0.8 85V 100V 132V 0.6 0.4 0.2 0.0 0 20 40 60 Load (%) 80 100 AC.200V TYPE: POWER FACTOR Power factor Power factor 0.15 0.05 AC.100V TYPE: EFFICIENCY 0 240V 265V 0.6 170V 240V 265V 0.4 0.2 0 20 40 60 Load (%) 80 0.0 100 AC.100V TYPE: SURGE CURRENT 0 20 40 60 Load (%) 80 100 AC.200V TYPE: SURGE CURRENT Vin=100V Vin=240V 30A 12.1A H : 5ms/Div V : 5A/Div Enlarged view H : 0.5ms/Div V : 5A/Div H : 5ms/Div V : 10A/Div Enlarged view H : 0.5ms/Div V : 10A/Div • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (23/30) Characteristics, Functions, and Applications JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0 AC.100/200V TYPE: –20°C START UP CHARACTERISTICS AC.100/200V TYPE: +60°C START UP CHARACTERISTICS AC.265V AC.265V AC.85V AC.85V H : 10ms/Div AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS H : 10ms/Div AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS Off Off 240V 240V 100V 100V H : 50ms/Div H : 50ms/Div 85V 85V H : 10ms/Div H : 10ms/Div H : 10ms/Div H : 10ms/Div AC.100V/200V TYPE: +60°C OVERCURRENT CURVE 7 7 6 6 5 Output voltage(V) Output voltage(V) AC.100V/200V TYPE: –20°C OVERCURRENT CURVE AC.85V 4 AC.240V AC.265V 3 2 AC.85V 4 AC.265V 3 AC.240V 2 AC.100V 1 0 AC.100V 5 1 0 1 2 3 Load current(A) 4 5 0 0 1 2 3 Load current(A) 4 5 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (24/30) Characteristics, Functions, and Applications AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 40 16 35 14 30 12 25 10 Life(Years) Life(Years) JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0 AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 20 15 10 30˚C 40˚C 50˚C 60˚C 70˚C 100 5 0 20 40 60 Load(%) 80 8 4 40˚C 2 50˚C 60˚C 70˚C 100 0 20 AC.100V TYPE: HOLD UP TIME 40 60 Load(%) 80 AC.200V TYPE: HOLD UP TIME 10000 1000 1000 Hold up time(ms) 10000 Hold up time(ms) 30˚C 6 100 115V 100V 10 240V 200V 170V 100 10 85V 1 10 25 50 Load(%) 75 1 100 10 25 50 Load(%) 75 100 CONDUCTIVE NOISE EMISSION [dBµV] [PEAK DATA] 100 90 80 70 60 VCCI(QP) 50 VCCI(AV) FCC-B 40 30 20 10 0 –10 0.15 0.5 1 5 10 20 30 Frequency [MHz] • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (25/30) Characteristics, Functions, and Applications JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0 AC.100V TYPE: INPUT CURRENT AC.200V TYPE: INPUT CURRENT 1.0 0.5 170V 0.4 85V 100V 0.6 132V 0.4 Input current(A) Input current(A) 0.8 0.2 0 0 20 40 60 Load(%) 80 20 40 60 Load(%) 80 100 100 132V 100V 85V 40 170V 240V 265V 80 Efficiency(%) 60 60 40 20 20 0 20 40 60 Load (%) 80 0 100 AC.100V TYPE: POWER FACTOR 0.8 0.8 85V 100V 132V 0.4 Power factor 1.0 0.6 0 20 40 60 Load (%) 80 100 AC.200V TYPE: POWER FACTOR 1.0 0.6 170V 240V 265V 0.4 0.2 0.2 0.0 0 AC.200V TYPE: EFFICIENCY 80 Efficiency(%) 0 100 100 Power factor 0.2 0.1 AC.100V TYPE: EFFICIENCY 0 240V 265V 0.3 0 20 40 60 Load (%) 80 0.0 100 AC.100V TYPE: SURGE CURRENT 0 20 40 60 Load (%) 80 100 AC.200V TYPE: SURGE CURRENT Vin=100V Vin=240V 31.2A 12.8A H : 5ms/Div V : 5A/Div H : 5ms/Div V : 10A/Div • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (26/30) Characteristics, Functions, and Applications JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0 AC.100/200V TYPE: –20°C START UP CHARACTERISTICS AC.100/200V TYPE: +60°C START UP CHARACTERISTICS AC.265V AC.265V AC.85V AC.85V H : 50ms/Div H : 50ms/Div AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS Off Off 170V 170V 100V 100V 85V 85V H : 10ms/Div H : 10ms/Div AC.100V/200V TYPE: –20°C OVERCURRENT CURVE AC.100V/200V TYPE: +60°C OVERCURRENT CURVE 7 7 6 AC.132V Output voltage(V) Output voltage(V) 6 5 AC.170V 4 3 AC.265V 2 5 AC.170V 4 3 AC.265V 2 AC.85V AC.85V 1 0 AC.132V 1 0 2 4 6 Load current(A) 8 10 0 0 2 4 6 Load current(A) 8 10 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (27/30) Characteristics, Functions, and Applications AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 16 8 14 7 12 6 10 5 Life(Years) Life(Years) JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0 AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 8 6 4 30˚C 2 40˚C 50˚C 60˚C 70˚C 100 0 20 40 60 Load(%) 80 4 2 0 20 1000 Hold up time(ms) 1000 Hold up time(ms) 10000 100 115V 100V 85V 10 60 Load(%) 80 75 240V 200V 170V 100 10 1 50 Load(%) 40 50˚C 60˚C 70˚C 100 AC.200V TYPE: HOLD UP TIME 10000 25 40˚C 1 AC.100V TYPE: HOLD UP TIME 10 30˚C 3 1 100 10 25 50 Load(%) 75 100 CONDUCTIVE NOISE EMISSION [dBµV] [PEAK DATA] 80 70 60 VCCI(QP) 50 VCCI(AV) FCC-B 40 30 20 10 0 –10 0.15 0.5 1 5 10 20 30 Frequency [MHz] • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (28/30) Characteristics, Functions, and Applications JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R AC.100V TYPE: INPUT CURRENT AC.200V TYPE: INPUT CURRENT 0.5 1.0 0.4 85V 100V 0.6 132V 0.4 Input current(A) Input current(A) 0.8 0.2 0.3 0.1 0 20 40 60 Load(%) 80 0 20 40 60 Load(%) 80 100 AC.200V TYPE: EFFICIENCY 100 100 132V 100V 85V 60 40 265V 240V 170V 80 Efficiency(%) 80 Efficiency(%) 0 100 AC.100V TYPE: EFFICIENCY 60 40 20 20 0 0 20 40 60 Load (%) 80 100 0 AC.100V TYPE: POWER FACTOR 20 40 60 Load (%) 80 100 AC.200V TYPE: POWER FACTOR 85V 100V 132V 1.0 170V 240V 265V 1.0 0.8 Power factor 0.8 Power factor 240V 265V 0.2 0 0 170V 0.6 0.4 0.6 0.4 0.2 0.2 0.0 0.0 0 20 40 60 Load (%) 80 0 100 AC.100V TYPE: SURGE CURRENT 20 40 60 Load (%) 80 100 AC.200V TYPE: SURGE CURRENT Vin=100V 16.2A Vin=240V 43A H : 5ms/Div V : 10A/Div H : 5ms/Div V : 20A/Div Enlarged view Enlarged view H : 0.2ms/Div V : 10A/Div H : 0.2ms/Div V : 20A/Div • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (29/30) Characteristics, Functions, and Applications JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R AC.100/200V TYPE: –20°C START UP CHARACTERISTICS AC.100/200V TYPE: +60°C START UP CHARACTERISTICS AC.265V AC.265V AC.85V AC.85V H : 50ms/Div H : 50ms/Div AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS Off Off AC.170V AC.170V AC.100V AC.100V AC.85V AC.85V H : 10ms/Div AC.100V/200V TYPE: +60°C OVERCURRENT CURVE 7 7 6 6 Output voltage(V) Output voltage(V) AC.100V/200V TYPE: –20°C OVERCURRENT CURVE H : 10ms/Div 5 4 3 5 4 3 2 2 AC.100V AC.100V 1 1 AC.240V AC.240V 0 0 0 4 8 12 Load current(A) 16 20 0 4 8 12 Load current(A) 16 20 • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm (30/30) Characteristics, Functions, and Applications AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 8 8 7 7 6 6 5 5 Life(Years) Life(Years) JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR 4 3 30˚C 4 3 30˚C 40˚C 1 50˚C 1 60˚C 50˚C 60˚C 0 0 20 40 60 Load(%) 80 20 100 AC.100V TYPE: HOLD UP TIME 40 60 Load(%) 80 100 AC.200V TYPE: HOLD UP TIME 1000 Hold up time(ms) 1000 Hold up time(ms) 40˚C 2 2 100 115V 100V 85V 10 1 10 25 50 Load(%) 75 100 240V 200V 170V 10 1 100 10 25 50 Load(%) 75 100 CONDUCTIVE NOISE EMISSION [dBµV] [PEAK DATA] 90 80 70 60 VCCI(QP) 50 VCCI(AV) FCC-B 40 30 20 10 0 0.15 0.5 1 5 10 20 30 Frequency [MHz] • All specifications are subject to change without notice. 004-02 / 20070523 / ea122_jbw.fm