Transcript
Cell Type HR-3URS Specifications Type : Nickel-Metal Hydride Battery 14.35 mm Size : AA Consumer Type Typical 2300mAh Minimum 2100mAh Capacity 1) Nominal Voltage 1.2V Constant Charging Voltage x Time Maximum Charging Current 50.4 mm Ambient Temp. Dimensions (with tube) D 14.35 mm H 50.4 mm Quick Charge 2) CV=1.64V x app.15min. Max.Current=10A Charge 2) CV=1.70V x app.70min. Max.Current=2.3A Charge Quick Charge 2) Condition 10°C - 40°C Charge 2) 0°C - 40°C Discharge Condition 0°C - 50°C Less than 30days -20°C - 50°C Storage Less than 90days Condition -20°C - 40°C Less than 1year -20°C - 30°C Internal Impedance 3) (after discharge to E.V.=1.0V) Weight Approx. 25mΩ(at 1000Hz) Approx. 30 g 4) Size 4) :(Diameter) x (Height) 14.35(D) x 50.4(H) mm 1)Single cell capacity under the following condition. Charge : CC;230mA+CV;CV=1.75V, Total Timer;16h, Discharge : 460mA(E.V.=1.0V) 2)Use recommended charging system. 3)After a few charge and discharge cycles under the above 1) condition 4)With tube. Typical Characteristics Charge Discharge 1.8 16 10° 1.5 40° 25° 40° 12 25° 1.4 10° 8 Cell Voltage (V) 1.6 Charge : 1.64V/10A x 16min Rest : 1h Discharge : 460mA, 1150mA, 2300mA, 4600mA (E.V.=1.0V) Ambient Temp. : 20°C 1.5 20 Current (A) 1.7 Cell Voltage (V) 1.6 24 Charge : 1.64V/10A x 16min Ambient Temp. : 10°C,25°C,40°C 1.4 1.3 1.2 1.1 1.3 4 1.0 1.2 0 0.9 460mA 1150mA 2300mA 4600mA 0 2 4 6 8 10 12 Charge Time (min.) 14 16 18 0 500 1000 1500 2000 Discharge Capacity (mAh) 2500