Download Rheem X-13 Sales Fact Sheet

Transcript
SALES FACT SHEET
RBHP- AIR HANDLERS
• Models featuring R-22 Refrigerant
• Models featuring Earth-Friendly
R-410A Refrigerant
• Models featuring Electric Heat without Indoor
Cooling Coil
earth friendly refrigerant
Features
Quiet and efficient X-13 motor technology
Only 35" tall and 4-way convertible for all those tight spaces
■ Available from factory in upflow and horizontal configurations
■ Nominal airflow up to 0.5" external static pressure with
reduced airflow up to 1.0" external static pressure
®
■ Factory installed MultiFlex coils
■ Sturdy double wall construction with .5 inch [12.7 mm] of
foil faced insulation for excellent sound and insulating
characteristics
■ Permanent, easily accessible and washable filter furnished
standard
■ Circuit breaker (standard on units with more than 11 kW)
meets U.L. and cUL requirements for service disconnect
■ Factory installed auxiliary electric heat provides exact heat
for indoor comfort over a variety of applications
■ Watt restrictors, standard on RBHP-17 models above 6 kW and
on RBHP-21, RBHP-24 and RBHP-25 models above 11 kW,
stage supplemental heat so that only the necessary amount is
engaged to maintain comfort in the conditioned space
■ Fan settings for selectable, customized cooling airflow over
a wide variety of applications
■
■
GENERAL TERMS OF LIMITED WARRANTY
Rheem® will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
Indoor Coils leaks caused by factory defects . . . . . . . . . . . . . .Five (5) Years
Electric Heating Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years
Any Other Part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years
For Complete Details of the Limited Warranty, including Applicable Terms & Conditions, See
Your Local Installer or Contact the Manufacturer for a Copy.
R
B
H
P — 17 J
00
Rheem
Classification
B = Blower Unit
Application
H = Heat Pump Air Handler
Design Series
P = X-13 Motor
Cabinet Size
17 = 17.5" [431.8 mm]
21 = 21.0" [533.4 mm]
24 = 24.5" [609.6 mm]
25 = 24.5" [635 mm]
Available Models
featuring R-22
Refrigerant
Available Models
featuring R-410A
Refrigerant
RBHP-17A00NHD
RBHP-17J06SHD
RBHP-17J07SHD
RBHP-17J17SHD
RBHP-21A00NHD
RBHP-21J06SHD
RBHP-21J07SHD
RBHP-21J11SHD
RBHP-21J14SHD
RBHP-24A00NHD
RBHP-24J06SHD
RBHP-24J07SHD
RBHP-24J11SHD
RBHP-24J14SHD
RBHP-24J18SHD
RBHP-25A00NHE
RBHP-25J11SHE
RBHP-25J14SHE
RBHP-25J18SHE
RBHP-25J21SHE
RBHP-17A00NH1
RBHP-17J06SH1
RBHP-17J07SH1
RBHP-17J11SH1
RBHP-21A00NH2
RBHP-21J06SH2
RBHP-21J07SH2
RBHP-21J11SH2
RBHP-21J14SH2
RBHP-24A00NH4
RBHP-24J06SH4
RBHP-24J07SH4
RBHP-24J11SH4
RBHP-24J14SH4
RBHP-24J18SH4
RBHP-25A00NH7
RBHP-25J11SH7
RBHP-25J14SH7
RBHP-25J18SH7
RBHP-25J21SH7
Rheem Heating, Cooling and Water Heating
P.O. Box 17010, Fort Smith, AR 72917
N
H
D
Coil Code
A = No Coil
Cabinet Width
Coil Refrigerant
Code
Type
D
E
1
2
4
7
R-22
R-22
R-410A
R-410A
R-410A
R-410A
17
21
24
25
RCHJ-24A1GH17 RCHJ-36A1GH21 RCHJ-48A1GH24
RCHJ-60A1GH24
RCHL-24A2GH17
RCHL-36A1GH21
RCHL-48A1GH24
RCHL-60A1GH24
Airflow
Horizontal Multi-Position
Control
N = No Circuit Protection (Single Circuit)
S = Circuit Breaker (Single Circuit)
Electric Heat
00 = No Heat
14 = 14.0 kW
06 = 4.9 kW
18 = 17.5 kW
07 = 7.0 kW
21 = 21.0 kW
11 = 10.0 kW
Voltage
A = 115V-1-60
J = 208/240V-1-60
Available Models
(without coils)
RBHP-17J11SHA
RBHP-21J14SHA
RBHP-24J18SHA
RBHP-25J21SHA
Starting at:
Price
PRINTED IN U.S.A.
$
FORM NO. H11-527-SFS REV. 3
DC
5-09
Related documents