Download Lightolier C12E28FL-PL User's Manual

Transcript
C12E28FL-PL
Calculite® HID Lensed Downlight
Page 1 of 3
12" Aperture, ED28 (Enclosed), Metal Halide, Prismatic or Fresnel Lens
10
4
8
1
5
2
3
7
9
6 11
20" (508 mm) to 30" (762 mm)
10-3/4"
(273 mm)
16-3/8" (416 mm)
13" (330 mm)
23-3/4" (603 mm) 320-400W
21-1/4" (540 mm) 175-250W
11"
(280 mm)
13-3/4"
(349 mm)
Vertical
Adjustment:
5/8" (16 mm
2 7/8" (73 m
Top View
Ceiling Cutout: 12 9/16” (256 mm) Dia.
Reflector Trim
C12E28PLWHW
Prismatic Lens, White Step Baffle.
C12E28FLWHW
Fresnel Lens, White Step Baffle.
2" (50 mm) max.
Ceiling Thickness
12" (305 mm) Dia.
13-1/4" (337 mm) Dia.
Frame-In Kit
Lamp (Enclosed, Coated)
C1217MHPU
C1225MHPU
C1232MHPU
C1240MHPU
C1217MHU
C1225MHU
C1240MHU
175W
250W
320W
400W
175W
250W
400W
Features
1. Reflector: Specular anodized aluminum, 16 ga. Removable from inside
fixture for access to splices and ballast.
2. Lens: Prismatic (C12E28PLWHW) or Fresnel (C12E28FLWHW) lens.
Regressed 2 1/4" from ceiling line.
3. Die-Cast Baffle: Painted white, deep conical step baffle for low brightness,
supports lens. Small Allen-head set screw provides secure attachment for
use where vandal resistant luminaires are required.
4. Torsiontite Springs: Permit removal of lens assembly without tools.
5. Socket Cup: Heat dissipating die-cast aluminum with medium base pulse
rated porcelain socket with nickel plated screw shell. Positive locking attachment, without tools, to reflector assures proper optical alignment of lamp.
6. Mounting Frame: 0.048" (18-ga.) galvanized steel, includes pre-installed
mounting bars.
7. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
8. Vertical Adjustment Mechanism: accommodates mounting to virtually
any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by
others). Single locking feature secures all adjustments. Alignment holes
and markings allow fixture to be preset prior to installation.
9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30"
long; lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation
in 24" O.C. grid systems. Attaches to steel/wood joists without accessories.
10. Ballast: Dual voltage (120V/277V) magnetic. Assembly is accessible from
below without tools for inspection and replacement.
11. Junction Box: 0.048" (18ga.) galvanized steel. UL listed for maximum of (8)
No. 12 AWG, 90°C through branch circuit conductors; allows inspection from
below
12. Thermal Protector: (not shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Magnetic, 120V/277V Pulse Start
Magnetic, 120V/277V Pulse Start
Magnetic, 120V/277V Pulse Start
Magnetic, 120V/277V Pulse Start
Magnetic, 120V/277V
Magnetic, 120V/277V
Magnetic, 120V/277V
ED28, BT28 PS MH
ED28, BT28 PS MH
ED28, BT28 PS MH
ED28, BT28 PS MH
ED28, BT28 MH
ED28, BT28 MH
ED28, BT28 MH
Electrical (Cont.)
Ballast
175W PS MH
250W PS MH
320W PS MH
400W PS MH
175W MH
250W MH
400W MH
ANSI Code
M137
M138
M132
M135
M57
M58
M59
Voltage
120/277
120/277
120/277
120/277
120/277
120/277
120/277
Max. Amps
2.20/0.90
2.80/1.20
3.40/1.50
4.10/1.80
2.00/0.90
2.60/1.10
3.90/1.70
Input Watts
205
290
370
465
205
290
460
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.
Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Wet Locations), CSA (magnetic ballast only), I.B.E.W.
For 320W/400W, install fixtures with minimum spacing: 4 feet from
center-to-center of adjacent luminaries; 3 inch from top of luminaire to overhead building member; 2 feet from luminaire center to side building member.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Electrical
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or
Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W
and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature,
Type 1 Outdoor rating.
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
C12E28FL-PL
Calculite® HID Lensed Downlight
Page 2 of 3
12" Aperture, ED28 (Enclosed), Metal Halide Prismatic or Fresnel Lens
FRESNEL LENS/ WHITE BAFFLE - 175W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 12900 LMS., ADVANCE BALLAST
ANGLE
0
0
5
10
15
60°
20
25
30
35
40
45
50
55
60
65
70
75
80
85
30°
90
1,500
3,000
4,500
6,000
** EFFICIENCY = 48.8% **
SC = .9
MEAN CP
8996
5781
5575
5247
4882
4348
3584
2713
1883
1250
859
608
448
341
259
201
142
47
14
0
LUMENS
529
1372
1647
1214
692
414
263
141
20
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
601630
CEILING
55
387161
WALL
65
303788
RCR
75
271565
85
79179
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
3547
27.5
56.38
4
0-40
4761
36.91
75.68
5
0-60
5867
45.49
93.26
0-90
6292
48.78
100
6
40-90
1530
11.86
24.32
7
60-90
424
3.29
6.74
8
90-180
0
0
0
9
0-180
6292
48.78
100
10
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.58
.55
.52
.49
.47
.44
.42
.40
.38
.36
.34
.58
.54
.50
.46
.43
.40
.37
.35
.33
.31
.29
.58
.52
.48
.43
.40
.37
.34
.32
.30
.28
.26
.58
.51
.46
.41
.38
.35
.32
.30
.28
.26
.24
.57
.53
.49
.45
.42
.39
.37
.35
.32
.30
.29
.57
.50
.45
.41
.38
.35
.32
.30
.27
.26
.24
.54
.50
.47
.44
.41
.39
.36
.34
.32
.30
.28
.54
.49
.44
.40
.37
.34
.32
.29
.27
.25
.24
.52
.49
.46
.43
.40
.38
.36
.33
.31
.30
.28
.52
.47
.43
.40
.37
.34
.32
.29
.27
.25
.24
.49
.45
.41
.38
.36
.33
.31
.28
.26
.25
.23
LUMINAIRE INPUT WATTS = 205
CERTIFIED TEST REPORT NO. 2554FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
FRESNEL LENS/ WHITE BAFFLE- 250W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 19475 LMS., UNIVERSAL BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
2,000
4,000
6,000
8,000
MEAN CP
7764
7645
7434
7120
6350
5182
3901
2741
1841
1276
908
668
506
385
299
210
71
21
0
LUMENS
728
1986
2386
1763
1026
617
391
209
31
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
893382
CEILING
55
576797
WALL
65
450887
RCR
75
400904
0
85
120690
1
2
ZONAL LUMENS AND PERCENTAGES
3
ZONE LUMENS % LAMP %LUMINAIRE
0-30
5099
26.18
55.82
4
0-40
6861
35.23
75.11
5
0-60
8504
43.67
93.1
6
0-90
9135
46.91
100
40-90
2273
11.67
24.89
7
60-90
630
3.24
6.9
8
90-180
0
0
0
9
0-180
9135
46.91
100
10
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.56 .56 .56 .56
.55 .55
.52 .52
.50 .50
.53 .51 .50 .49
.51 .48
.49 .47
.47 .45
.50 .48 .46 .44
.47 .43
.45 .42
.44 .41
.47 .44 .42 .40
.43 .39
.42 .39
.41 .38
.45 .41 .38 .36
.41 .36
.40 .36
.39 .35
.42 .38 .35 .33
.38 .33
.37 .33
.36 .32
.40 .36 .33 .31
.35 .31
.35 .30
.34 .30
.38 .33 .30 .28
.33 .28
.32 .28
.32 .28
.36 .31 .28 .26
.31 .26
.30 .26
.30 .26
.34 .29 .26 .24
.29 .24
.29 .24
.28 .24
.32 .28 .25 .23
.27 .23
.27 .23
.27 .23
0
.47
.43
.40
.37
.34
.31
.29
.27
.25
.23
.22
LUMINAIRE INPUT WATTS = 290
** EFFICIENCY = 46.9% **
SC = .9
CERTIFIED TEST REPORT NO. 2557FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
FRESNEL LENS/ WHITE BAFFLE - 320W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 30100 LMS., ADVANCE BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
2,750
5,500
8,250
11,000
** EFFICIENCY = 42.6% **
SC = .9
MEAN CP
10463
10298
10043
9696
8873
7298
5523
3882
2614
1810
1287
953
724
557
433
307
128
31
1
LUMENS
981
2715
3355
2497
1456
878
564
311
52
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
1267525
CEILING
55
822644
WALL
65
652886
RCR
75
588204
85
177806
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
7050
23.42
55.05
4
0-40
9547
31.72
74.54
5
0-60
11882
39.47
92.77
0-90
12808
42.55
100
6
40-90
3260
10.83
25.46
7
60-90
926
3.08
7.23
8
90-180
0
0
0
9
0-180
12808
42.55
100
10
Coefficients of Utilization
80%
70%
50%
30%
70 50 30 10
50 10
50 10
50 10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.51
.48
.45
.43
.41
.38
.36
.34
.33
.31
.29
.51
.47
.43
.40
.37
.35
.32
.30
.28
.26
.25
.51
.45
.41
.38
.35
.32
.30
.27
.25
.24
.22
.51
.44
.40
.36
.33
.30
.28
.26
.24
.22
.20
.49
.46
.42
.39
.37
.34
.32
.30
.28
.26
.25
.49
.44
.39
.35
.32
.30
.28
.25
.24
.22
.20
.47
.44
.41
.38
.36
.33
.31
.29
.27
.26
.24
.47
.42
.38
.35
.32
.30
.27
.25
.23
.22
.20
.45
.42
.40
.37
.35
.33
.31
.29
.27
.25
.24
.45
.41
.37
.34
.32
.29
.27
.25
.23
.22
.20
.43
.39
.36
.33
.31
.28
.26
.24
.23
.21
.19
LUMINAIRE INPUT WATTS = 370
CERTIFIED TEST REPORT NO. 2558FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
FRESNEL LENS/ WHITE BAFFLE - 400W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 35000 LMS. ADVANCE BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
3,750
7,500
11,250
15,000
** EFFICIENCY = 49.2% **
SC= .9
MEAN CP
15666
15225
14335
13279
11715
9625
7341
5183
3500
2420
1711
1256
950
719
559
396
138
41
0
LUMENS
1443
3728
4433
3331
1946
1160
731
394
60
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
CEILING
45
1695165
55
1084702
WALL
65
842680
RCR
75
758600
0
85
235481
1
2
ZONAL LUMENS AND PERCENTAGES
3
ZONE LUMENS % LAMP %LUMINAIRE
0-30
9603
27.44
55.75
4
0-40
12933
36.95
75.08
5
0-60
16040
45.83
93.12
6
0-90
17225
49.22
100
7
40-90
4291
12.26
24.92
60-90
1185
3.39
6.88
8
90-180
0
0
0
9
0-180
17225
49.22
100
10
CERTIFIED TEST REPORT NO. 2561FR, DATE: MAR 22, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
Coefficients of Utilization
80%
70%
50%
30%
70 50 30 10
50 10
50 10
50 10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.59
.56
.52
.50
.47
.45
.42
.40
.38
.36
.34
.59
.54
.50
.46
.43
.40
.38
.35
.33
.31
.29
.59
.53
.48
.44
.40
.37
.35
.32
.30
.28
.26
.59
.51
.46
.42
.38
.35
.32
.30
.28
.26
.24
.57
.53
.49
.46
.43
.40
.37
.35
.32
.31
.29
.57
.51
.45
.41
.38
.35
.32
.30
.28
.26
.24
.55
.51
.47
.44
.42
.39
.36
.34
.32
.30
.28
.55
.49
.44
.41
.37
.34
.32
.30
.27
.25
.24
.52
.49
.46
.43
.41
.38
.36
.33
.31
.30
.28
.52
.48
.44
.40
.37
.34
.32
.29
.27
.25
.24
.49
.45
.42
.39
.36
.33
.31
.28
.26
.25
.23
LUMINAIRE INPUT WATTS = 460
Job Information
Type:
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Calculite® HID Lensed Downlight
Page 3 of 3
C12E28FL-PL
12" Aperture, ED28 (Enclosed), Metal Halide or Prismatic Fresnel Lens
PRISMATIC LENS- 175W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 12900 LMS., ADVANCE BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
1,750
3,500
5,520
7,000
** EFFICIENCY = 47.2% **
SC = .8
MEAN CP
6780
6578
6049
5291
4420
3463
2522
1734
1149
765
522
352
248
195
138
79
36
11
0
LUMENS
620
1492
1605
1121
620
331
192
88
16
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
536031
CEILING
55
303825
WALL
65
227960
RCR
75
152040
85
61798
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
3716
28.81
61.08
4
0-40
4837
37.5
79.51
5
0-60
5788
44.87
95.13
0-90
6084
47.17
100
6
40-90
1246
9.66
20.49
7
60-90
296
2.3
4.87
8
90-180
0
0
0
9
0-180
6084
47.17
100
10
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.56
.53
.51
.48
.46
.44
.42
.39
.38
.36
.34
.56
.52
.49
.45
.43
.40
.38
.35
.33
.31
.30
.56
.51
.47
.43
.40
.37
.35
.32
.30
.29
.27
.56
.50
.45
.41
.38
.35
.33
.31
.29
.27
.25
.55
.51
.48
.45
.42
.39
.37
.35
.33
.31
.29
.55
.49
.45
.41
.38
.35
.33
.30
.28
.27
.25
.52
.49
.46
.43
.41
.39
.36
.34
.32
.31
.29
.52
.48
.44
.40
.37
.35
.32
.30
.28
.26
.25
.50
.47
.45
.42
.40
.38
.36
.34
.32
.30
.29
.50
.46
.43
.40
.37
.34
.32
.30
.28
.26
.25
.47
.44
.41
.38
.36
.33
.31
.29
.27
.26
.24
LUMINAIRE INPUT WATTS = 205
CERTIFIED TEST REPORT NO. 2555FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
PRISMATIC LENS- 250W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 19475 LMS., UNIVERSAL BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
2,125
4,250
6,375
8,500
** EFFICIENCY = 47.4% **
SC = .9
MEAN CP
8614
8519
8224
7721
6846
5413
3961
2739
1818
1217
830
560
398
308
220
129
60
20
0
LUMENS
808
2162
2503
1768
984
526
306
142
27
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
852701
CEILING
55
483130
WALL
65
361094
RCR
75
246762
85
111021
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
5473
28.11
59.32
4
0-40
7241
37.19
78.48
5
0-60
8752
44.94
94.85
0-90
9227
47.38
100
6
40-90
1986
10.2
21.52
7
60-90
475
2.44
5.15
8
90-180
0
0
0
9
0-180
9227
47.38
100
10
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.56
.54
.51
.48
.46
.44
.41
.39
.37
.35
.34
.56
.52
.49
.45
.42
.40
.37
.35
.33
.31
.29
.56
.51
.47
.43
.40
.37
.34
.32
.30
.28
.26
.56
.50
.45
.41
.38
.35
.32
.30
.28
.26
.24
.55
.51
.48
.45
.42
.39
.37
.35
.32
.30
.29
.55
.49
.44
.41
.37
.35
.32
.30
.28
.26
.24
.53
.49
.46
.43
.41
.38
.36
.34
.32
.30
.28
.53
.48
.43
.40
.37
.34
.32
.30
.28
.26
.24
.50
.47
.45
.42
.40
.37
.35
.33
.31
.30
.28
.50
.46
.43
.39
.37
.34
.32
.29
.28
.26
.24
.47
.44
.41
.38
.35
.33
.31
.29
.27
.25
.23
LUMINAIRE INPUT WATTS = 290
CERTIFIED TEST REPORT NO. 2556FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
PRISMATIC LENS - 320W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 30100 LMS., ADVANCE BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
3,750
7,500
11,250
15,000
** EFFICIENCY = 44.5%
SC = .8
MEAN CP
14920
14486
13317
11664
9775
7649
5553
3810
2513
1681
1138
771
554
426
306
174
78
18
0
LUMENS
1365
3290
3544
2463
1358
725
425
193
31
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
1177083
CEILING
55
665377
WALL
65
499041
RCR
75
332156
85
103373
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
8198
27.24
61.21
4
0-40
10662
35.42
79.6
5
0-60
12744
42.34
95.15
0-90
13394
44.5
100
6
40-90
2732
9.08
20.4
7
60-90
649
2.16
4.85
8
90-180
0
0
0
9
0-180
13394
44.5
100
10
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.53
.50
.48
.46
.43
.41
.39
.37
.36
.34
.32
.53
.49
.46
.43
.40
.38
.35
.33
.31
.30
.28
.53
.48
.44
.41
.38
.35
.33
.31
.29
.27
.25
.53
.47
.42
.39
.36
.33
.31
.29
.27
.25
.24
.52
.48
.45
.42
.40
.37
.35
.33
.31
.29
.28
.52
.46
.42
.39
.36
.33
.31
.29
.27
.25
.24
.49
.46
.44
.41
.39
.36
.34
.32
.31
.29
.27
.49
.45
.41
.38
.35
.33
.31
.29
.27
.25
.23
.47
.45
.42
.40
.38
.36
.34
.32
.30
.28
.27
.47
.43
.40
.37
.35
.32
.30
.28
.27
.25
.23
.44
.41
.39
.36
.34
.31
.30
.28
.26
.24
.23
LUMINAIRE INPUT WATTS = 370
**CERTIFIED TEST REPORT NO. 2559FR, DATE: MAR 21, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
PRISMATIC LENS - 400W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 35000 LMS. ADVANCE BALLAST
ANGLE
0
5
10
15
20
60°
25
30
35
40
45
50
55
60
65
70
75
80
85
90
30°
5,000
10,000
15,000
20,000
** EFFICIENCY = 50.4% **
SC = .8
MEAN CP
19667
19072
17547
15345
12839
10059
7317
5028
3325
2217
1504
1006
712
557
395
226
103
29
0
LUMENS
1798
4328
4660
3251
1794
948
551
251
44
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
1553151
CEILING
55
869063
WALL
65
652850
RCR
75
432092
85
166222
0
1
ZONAL LUMENS AND PERCENTAGES
2
ZONE LUMENS % LAMP %LUMINAIRE
3
0-30
10786
30.82
61.2
4
0-40
14037
40.11
79.64
5
0-60
16779
47.94
95.2
0-90
17625
50.36
100
6
40-90
3588
10.25
20.36
7
60-90
846
2.42
4.8
8
90-180
0
0
0
9
0-180
17625
50.36
100
10
CERTIFIED TEST REPORT NO. 2560FR, DATE: MAR 22, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
Coefficients of Utilization
80%
70
50
30
70%
10
50
10
50%
50
10
30%
50
10
0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
.60
.57
.54
.52
.49
.47
.45
.42
.40
.38
.36
.60
.56
.52
.48
.45
.43
.40
.38
.35
.33
.32
.60
.54
.50
.46
.43
.40
.37
.35
.33
.30
.29
.60
.53
.48
.44
.41
.38
.35
.33
.30
.28
.27
.59
.55
.51
.48
.45
.42
.40
.37
.35
.33
.31
.59
.52
.48
.44
.40
.37
.35
.32
.30
.28
.27
.56
.52
.49
.46
.44
.41
.39
.37
.35
.33
.31
.56
.51
.46
.43
.40
.37
.35
.32
.30
.28
.27
.54
.51
.48
.45
.43
.40
.38
.36
.34
.32
.31
.54
.49
.46
.42
.39
.37
.34
.32
.30
.28
.26
.50
.47
.44
.41
.38
.36
.33
.31
.29
.27
.26
LUMINAIRE INPUT WATTS = 460
Job Information
Type:
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504