Download Goodman Mfg R-410A User's Manual

Transcript
TECHNICAL MANU
AL
MANUAL
GPC 14 SEER R-410A
Package Air Conditioners
with R-410A
• Refer to Service Manual RS6300011 (Horizontal)
for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
• Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency**
**Note that these tax credits are subject to specific requirements set forth in the American Recovery and
Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult
a tax professional if they have questions about the applicability of these credits.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not
assume any responsibility for property damage or personal injury due to improper service procedures or
services performed by an unqualified person.
Copyright © 2009 Goodman Manufacturing Company, L.P.
RT6322007r2
August 2009
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
G
P
C
14
24
H
4
1
A
VOLTAGE:
1: 208-230v
1ph/60Hz
BRAND:
G: Goodman®
A
MINOR REVISION:
A: Initial Release
PRODUCT
FAMILY:
C: Cooling
Brand
REFRIGERANT:
4: R-410A
PRODUCT
TYPE:
Package Unit
PRODUCT
SERIES:
SEER Rating
CONFIGURATION:
H: Horizontal
MAJOR REVISION:
A: Initial Release
NOMINAL
CAPACITY
24: 24,000 BTUH
30: 30,000 BTUH
36: 36,000 BTUH
42: 42,000 BTUH
48: 48,000 BTUH
60: 60,000 BTUH
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
WARNING
2
Installation and repair of this unit
should be performed ONLY by
individuals meeting the requirements of an "entry level
technician" as specified by the Air-Conditioning, Heating,
and Refrigeration Institute (AHRI). Attempting to install
or repair this unit without such background may result
in product damage, personal injury or death.
WARNING
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
GPC1424H41A*
GPC1430H41A*
GPC1436H41A*
GPC1442H41A*
GPC1448H41A*
GPC1460H41A*
Models qualify for the 2009 and 2010 Federal Tax Credits
for Energy Efficiency**
**Note that these tax credits are subject to specific requirements set forth in the American
Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman
recommends that consumers consult a tax professional if they have questions about the
applicability of these credits.
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
WARNING
To prevent the risk of property
damage, personal injury, or death,
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
WARNING
3
PRODUCT DESIGN
GPC Package Cooling Units are designed for outdoor installations only in either residential or light commercial applications.
-
Due to their design Scroll Compressors are inherently
more tolerant of liquid refrigerant. NOTE: Even though the
compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded
start conditions may wash oil from the bearing surfaces
causing premature bearing failure.
-
Scroll Compressors use white oil which is compatible
with 3GS oil which may be used if additional oil is required.
-
Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be
found in the "Cooling Performance Data" section.
The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical
application a matching Roof Curb is recommended.
A return air filter must be installed behind the return air grille(s)
or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should
not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated
without return air filters.
A 3/4” PVC pipe is provided for removal of condensate water
from the indoor coil In order to provide proper condensate
flow, a drain trap is supplied and shipped loose inside the
unit for field installation. (Do not reduce the drain line size.)
Refrigerant flow control is achieved by use of restrictor orifices. GPC units use the FasTest Access Fitting System
with a saddle that is either soldered to the suction and liquid
lines or is fastened with a locking nut to the access fitting
box (core) and then screwed into the saddle. Do not remove the core from the saddle until the refrigerant
charge has been removed. Failure to do so could result in property damage or personal injury.
Location and Clearances
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.
10"
36"
The single phase units use permanent split capacitor (PSC)
design compressors. Starting components are therefore not
required for these units. A low microfarad run capacitor assists the compressor to start and remains in the circuit during operation.
WALL
UNIT
All GPC14 units have X-13 indoor blower motors that are energized by a 24V signal from the thermostat and are constant torque motors with very low power consumption. The X13 features an integral control module.
Air for condensing (cooling cycle) is drawn through the outdoor coil by a propeller fan, and is discharged vertically out
the top of the unit. The outdoor coil is designed for .0 static.
No additional restriction (ductwork) shall be applied.
Conditioned air is drawn through the filter(s), field installed,
across the coil and back into the conditioned space by the
indoor blower.
GPC1424-30H41* use Copeland Reciprocating Compressors.
GPC1436-60H41* use Copeland Scroll Compressors. There
are a number of design characteristics which are different
from the traditional reciprocating compressor.
4
36"
36"
Outside Slab Installation - Horizontal (H)
Minimum clearances are required to avoid air recirculation and
keep the unit operating at peak efficiency.
PRODUCT DESIGN
In installations where the unit is installed above ground level
and not serviceable from the ground (Example: Roof Top installations), the installer must provide service platform for service person with rails or guards in accordance with local codes
or ordinances or in their absence with the latest edition of the
Uniform Mechanical Code Section 305.
36"
UN
I
T
NOTE: Unit can also use roof curb.
PL
EN
UM
24"
PL
AT
F
OR
RB
CU
M
36"
Rooftop Installation - Horizontal (H)
WARNING
TO PREVENT POSSIBLE PROPERTY DAMAGE, THE
UNIT SHOULD REMAIN IN AN UPRIGHT POSITION
DURING ALL RIGGING AND MOVING OPERATIONS.
TO FACILITATE LIFTING AND MOVING IF A CRANE
IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE
SLING.
Refer to Roof Curb Installation Instructions for proper curb
installation. Curbing must be installed in compliance with
the National Roofing Contractors Association Manual.
5
PRODUCT DESIGN
GPC14[24-60]H41A*
HKR ELECTRICAL DATA
Circuit #1
Model and Heat Kit Usage
GPH1424H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
GPH1430H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
HKR15*,C*
GPH1436H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
HKR15*,C*
GPH1442H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
HKR15*,C*
HKR20*,C*
GPH1448H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
HKR15*,C*
HKR20*,C*
GPH1460H41A*
HKR05*,C*
HKR08*,C*
HKR10*,C*
HKR15*,C*
HKR20*,C*
Circuit #2
Minimum Circuit
Ampacity
at 208 / 240V
Maximum
Overcurrent
Protection (amps)
at 208 / 240V
Minimum Circuit
Ampacity
at 208 / 240V
Maximum
Overcurrent
Protection (amps)
at 208 / 240V
Actual
kW & BTU
at 240V
24 / 27
33 / 28
45 / 51
30 / 30
40 / 40
60 / 60
----------
----------
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
24 / 27
30 / 30
----
----
4.75 / 16,200
34 / 39
45 / 52
45 / 52
40 / 40
60 / 60
60 / 60
------22 / 25
------30 / 30
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
24 /
34 /
45 /
45 /
27
39
52
52
30 / 30
40 / 40
60 / 60
60 / 60
---------22 / 25
---------30 / 30
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
25 / 27
34 / 39
30 / 30
40 / 40
-------
-------
4.75 / 16,200
7.00 / 23,800
46 / 52
46 / 52
46 / 52
60 / 60
60 / 60
60 / 60
---22 / 25
43 / 49
---30 / 30
60 / 60
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500
25 /
34 /
46 /
46 /
46 /
28
40
53
52
52
30 / 30
40 / 40
60 / 60
60 / 60
60 / 60
---------22 / 25
43 / 49
---------30 / 30
60 / 60
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500
26 / 30
36 / 40
48 / 54
30 / 30
40 / 40
60 / 60
----------
----------
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
48 / 54
48 / 54
60 / 60
60 / 60
22 / 25
43 / 49
30 / 30
60 / 60
14.25 / 48,600
19.50 / 66,500
IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.
WARNING
6
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
PRODUCT DIMENSIONS
GPC14[24-60]H41A*
A
14.000
4.512
4.500
14.000
SUPPLY
6.500
14.000
RETURN
BACK VIEW
(DUCT OPENINGS)
66.542
B
34.075
Chassis
Small
Model
A
B
GPC1424
33
30½
GPC1430
33
30½
GPC1436
33
35½
GPC1442
33
35½
GPC1448
33
38½
GPC1460
33
38½
Medium
Large
Dimensions in inches
7
PACKAGE COOLING SPECIFICATIONS
COOLING
COOLING CAPACITY, BTUH
CAPACITY
SEER / EER
UNIT
VOLTAGE (NAMEPLATE)
ELECTRICAL
SPECIFICATION
GPC14[24-36]H41A*
GPC1424H41*
GPC1430H41*
GPC1436H41*
24,600
28,400
35,600
14.5 / 12.1
14.0 / 12.0
14.0 / 12.0
208-230/1/60
208-230/1/60
208-230/1/60
AMPS (TOTAL)
10.5
13.16
20.06
MINIMUM CIRCUIT AMPACITY
12.5
15.6
24.2
20
25
40
MAXIMUM OVERCURRENT PROTECTION
(1)
RECIP
RECIP
SCROLL
RATED LOAD AMPS
7.9
9.8
16.7
LOCKED ROTOR AMPS
41
55
79
CONDENSER
HORSEPOWER
1/6
1/4
1/4
FAN MOTOR
RPM
815
830
830
FULL LOAD AMPS
1.1
1.5
1.5
COMPRESSOR
TYPE
LOCKED ROTOR AMPS
CONDENSER FAN
BLADE DIAMETER (INCHES) / NUMBER OF BLADES
CONDENSER
FACE AREA - SQ. FT.
COIL
NUMBER OF ROWS
FINS PER INCH
1.7
3.0
3.0
22 / 3
22 / 3
22 / 3
13.4
13.4
13.4
1
1
1
24
24
24
1/2 - 5
1/2 - 5
1/2 - 5
FULL LOAD AMPS
1.5
1.86
1.86
LOCKED ROTOR AMPS
NA
NA
NA
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS
BLOWER
MOTOR
MOTOR SPEED TAP - COOLING
RPM
T2
T2
T2
1050
1050
1050
EVAPORATOR
DIAMETER X W IDTH (INCHES)
10 X 8
10 X 8
10 X 8
BLOWER
HI EFFICIENCY COOLING CFM
850
1,050
1,200
5 TON NOMINAL COOLING CFM
NA
NA
NA
FAN ONLY COOLING CFM
800
950
1,100
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
EVAPORATOR
FACE AREA - SQ. FT.
5.25
4.67
5.2
COIL
NUMBER OF ROWS
3
4
3
FINS PER INCH
16
16
14
GENERAL
FILTER SIZE - SQ. FT. *
20 x 20 x 1
20 x 25 x 1
25 x 25 x 1
INFORMATION
DRAIN SIZE (INCHES)
3/4"
3/4"
3/4"
EXPANSION DEVICE
ORIFICE (0.057)
ORIFICE (0.060)
ORIFICE (0.065)
83
78
80
REFRIGERANT CHARGE R-410A (Oz.)
3/4, 1, 1-1/4
3/4, 1, 1-1/4
3/4, 1, 1-1/4
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)
1/2
1/2
1/2
SHIPPING WEIGHT LBS.
310
310
370
OPERATING WEIGHT LBS.
300
300
360
POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
(1)
*
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
WARNING
8
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
PACKAGE COOLING SPECIFICATIONS
GPC14[42-60]H41*
GPC1442H41*
GPC1448H41*
GPC1460H41*
40,500
46,500
57,500
COOLING
COOLING CAPACITY, BTUH
CAPACITY
SEER / EER
UNIT
VOLTAGE (NAMEPLATE)
ELECTRICAL
AMPS (TOTAL)
22.2
24.2
30.7
SPECIFICATION
MINIMUM CIRCUIT AMPACITY
26.6
29.1
37.3
MAXIMUM OVERCURRENT PROTECTION (1)
COMPRESSOR
14.5 / 12.0
14.5 / 12.1
14.2 / 12.0
208-230/1/60
208-230/1/60
208-230/1/60
40
45
60
SCROLL
SCROLL
SCROLL
RATED LOAD AMPS
17.9
19.9
26.4
LOCKED ROTOR AMPS
112
109
134
TYPE
CONDENSER
HORSEPOWER
FAN MOTOR
RPM
FULL LOAD AMPS
LOCKED ROTOR AMPS
CONDENSER FAN
BLADE DIAMETER (INCHES) / NUMBER OF BLADES
CONDENSER
FACE AREA - SQ. FT.
COIL
NUMBER OF ROWS
FINS PER INCH
1/4
1/4
1/4
1075
1075
1075
1.4
1.4
1.4
2.9
2.9
2.9
22 / 4
22 / 4
22 / 4
17.0
19.1
19.1
1
1
2
24
21
16
1/2 - 5
3/4 - 5
3/4 - 5
FULL LOAD AMPS
2.9
2.9
2.9
LOCKED ROTOR AMPS
NA
NA
NA
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS
BLOWER
MOTOR
MOTOR SPEED TAP - COOLING
T2
T2
T2
RPM
1050
1050
1050
EVAPORATOR
DIAMETER X W IDTH (INCHES)
10 x 8
10 x 8
11 x 8
BLOWER
HI EFFICIENCY COOLING CFM
1,300
1,600
1,600
5 TON NOMINAL COOLING CFM
NA
NA
1,800
1,200
1,400
1,600
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
EVAPORATOR
FACE AREA - SQ. FT.
6.2
6.2
7.0
COIL
NUMBER OF ROWS
4
4
4
FAN ONLY COOLING CFM
FINS PER INCH
14
14
14
(2) 20 x 20 x 1
(2) 20 x 20 x 1
(2) 20 x 25 x 1
GENERAL
FILTER SIZE - SQ. FT. *
INFORM ATION
DRAIN SIZE (INCHES)
3/4"
3/4"
3/4"
EXPANSION DEVICE
ORIFICE (0.072)
ORIFICE (0.076)
ORIFICE (0.088)
REFRIGERANT CHARGE R-410A (Oz.)
POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
118
123
188
3/4, 1, 1-1/4
3/4, 1, 1-1/4
3/4, 1, 1-1/4
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)
1/2
1/2
1/2
SHIPPING WEIGHT LBS.
370
400
400
OPERATING WEIGHT LBS.
360
390
390
(1)
*
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
WARNING
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
9
GPC14[24-60]H41A*
ACCESSORIES
ACCESSORIES - GPC/GPH****H UNITS
Part Number
Description
OT18-60A
Outdoor Thermostat Kit w/Lockout Stat
OT/EHR18-60
Emergency Heat Relay Kit
HKR
Electric Heat Kit
PCCP101-103
Roof Curb
PCP101-103
Downflow Plenum Kit
PCP101-103R8
Downflow Plenum Kit w/ R-8 Insulation
PCEC101-103
Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103
PCEH101-103
Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103
PCMD101-103
Manual Damper - To Be Used With PCP101-103
PCMDM101-103
Motorized Damper - To Be Used With PCP101-103
GPHMD101-103
Manual Damper for Horizontal Applications
SQRPCH101
Square to Round Adapters 16"&14"
SQRPCH102-103
Square to Round Adapters 18"&14"
SQRPC101
Square to Round Adapter - For Use With PCCP101-103 Curb 16" Rounds
SQRPC102-103
Square to Round Adapter For Use With PCCP101-103 Curb 18" Rounds
PCFR101-103
External Horizontal Filter Rack
PCEF101-103
Elbow & Flashing w/ R-8 Liner
CDK36
Flush Mount Concentric Duct Kit
CDK36515
Flush Mount Concentric Duct Kit w/ Filter
CDK36530
Step Down Concentric Duct Kit
CDK36535
Step Down Concentric Duct Kit w/ Filter
CDK4872
Flush Mount Concentric Duct Kit
CDK4872515
Flush Mount Concentric Duct Kit w/ Filter
CDK4872530
Step Down Concentric Duct Kit
CDK4872535
Step Down Concentric Duct Kit w/ Filter
10
GPC14[24-60]H41A*
BLOWER PERFORMANCE DATA
Dry Coil Data
GPC1460H41**
GPC1448H41**
GPC1442H41**
GPC1436H41**
GPC1430H41**
GPC1424H41**
Model
Speed
T1
Volts
230
T2,T3
230
T4, T5
230
T1
230
T2,T3
230
T4, T5
230
T1
T2,T3
T4, T5
T1
T2,T3
T4, T5
T1
T2,T3
T4, T5
T1, T2, T3
T4, T5
230
230
230
230
230
230
230
230
230
230
230
E.S.P (In. of H2O)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
934
759
755
638
581
489
-
-
WATTS
95
77
76
73
83
90
-
-
CFM
990
837
801
744
696
652
601
-
WATTS
107
94
105
110
119
133
142
-
CFM
1061
989
947
925
876
-
-
-
WATTS
126
134
146
158
169
-
-
-
CFM
1022
929
894
829
797
748
695
643
WATTS
116
114
126
134
144
156
168
173
CFM
1103
1063
1012
962
937
-
-
-
WATTS
142
154
165
173
185
-
-
-
CFM
1285
1240
1202
1163
1124
1076
1046
1003
WATTS
205
218
231
244
257
268
280
288
CFM
1234
1111
1071
1024
933
922
-
-
WATTS
144
140
152
164
179
183
-
-
CFM
1287
1232
1186
1133
1099
1053
-
-
WATTS
162
175
187
201
213
221
-
-
CFM
1381
1325
1277
1233
1181
1144
-
-
WATTS
195
203
217
233
247
258
-
-
CFM
1272
1197
1145
1106
1055
998
947
906
WATTS
160
168
183
191
211
220
230
243
CFM
1357
1297
1244
1194
1147
1099
1049
1008
WATTS
188
202
213
228
245
255
267
284
CFM
1537
1478
1431
1386
1336
1293
1253
1208
WATTS
244
258
274
288
303
317
329
341
CFM
1418
1383
1349
1312
1275
1228
1178
1141
WATTS
242
258
273
282
299
308
320
338
CFM
1175
1635
1645
1515
1510
1450
1430
1400
WATTS
395
420
435
445
455
465
470
475
CFM
1845
1790
1715
1685
1590
1580
1530
1500
WATTS
490
505
520
535
550
560
570
575
CFM
1775
1635
1645
1515
1510
1450
1430
1400
WATTS
395
420
435
445
455
465
470
475
CFM
2025
1900
1840
1780
1725
1650
1620
1580
WATTS
575
595
620
630
645
655
660
670
NOTES:
1. Data shown is dry coil. Wet coil pressure drop is approx.
2. 0.1" H2 O, for 2 row indoor coil; 0.2” H2O, for 3 row indoor coil; and 0.3” H2 O, for 4 row indoor coil.
3. Data shown does not include filter pressure drop, approx. 0.08” H2 O.
4. Reduce airflow by 2% for 208V operation.
11
12
10
20
30
40
50
60
70
30
80
90
100
40
50
60
700
600 CFM
90
100
2000
2200
2400 CFM
1800
1600
1400
OUTPUT BTU/HR x 1000
80
1200
1100
1000
900
70
800
FORMULAS
110
120
130
140
BTU OUTPUT = CFM x 1.08 x RISE
BTU OUTPUT
RISE =
÷ CFM
1.08
BTU OUTPUT vs TEMPERATURE RISE CHART
150
BLOWER PERFORMANCE DATA
TEMPERATURE RISE
EXPANDED PERFORMANCE DATA
21.6
0.68
18
1.52
6.4
224
107
24.5
0.84
20
1.58
6.7
236
112
23.8
0.81
21
1.57
6.6
233
111
22.0
0.78
21
1.53
6.5
226
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
850
745
955
850
745
22.6
0.69
19
1.56
6.6
244
115
24.5
0.72
19
1.60
6.8
251
118
25.2
0.76
18
1.62
6.8
254
120
22.4
0.57
16
1.55
6.6
241
114
24.3
0.59
16
1.59
6.7
249
117
24.5
0.53
16
1.61
6.8
257
125
26.5
0.55
16
1.66
7.0
265
129
27.3
0.57
15
1.67
7.1
268
131
24.5
0.40
12
1.60
6.8
255
124
26.6
0.41
12
1.64
6.9
263
128
26.3
0.34
11
1.67
7.1
268
134
28.5
0.35
11
1.71
7.2
277
138
29.3
0.37
10
1.73
7.3
279
139
-
-
21.5
0.81
21
1.65
7.0
254
114
23.2
0.83
21
1.70
7.1
262
118
23.9
0.88
20
1.71
7.2
265
119
21.1
0.71
18
1.64
6.9
252
113
22.9
0.73
18
1.68
7.1
259
116
22.1
0.72
20
1.69
7.1
273
121
23.9
0.75
19
1.73
7.3
282
125
24.7
0.78
19
1.75
7.4
285
126
21.9
0.59
16
1.68
7.1
271
120
23.7
0.61
16
1.72
7.2
279
124
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
70
23.4
0.71
18
1.56
6.6
231
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
25.7
0.35
11
1.81
7.6
301
141
27.8
0.36
11
1.85
7.8
310
145
28.6
0.38
11
1.87
7.9
314
147
-
-
20.9
0.83
21
1.76
7.5
289
119
22.7
0.86
21
1.81
7.7
298
122
23.4
0.90
20
1.82
7.8
301
123
20.6
0.73
18
1.75
7.5
286
117
22.3
0.75
18
1.79
7.7
295
121
21.6
0.74
20
1.80
7.7
311
126
23.4
0.77
19
1.85
7.9
321
130
24.1
0.80
19
1.87
8.0
324
131
21.3
0.61
16
1.79
7.6
308
125
23.1
0.63
16
1.83
7.8
317
129
23.3
0.56
16
1.86
7.9
328
138
25.3
0.58
16
1.91
8.1
339
142
26.0
0.61
15
1.93
8.2
342
143
23.4
0.42
12
1.85
7.9
325
136
25.3
0.44
12
1.90
8.1
335
141
25.1
0.36
11
1.93
8.2
343
147
27.1
0.37
11
1.98
8.4
353
151
28.0
0.39
11
2.00
8.5
357
153
-
-
20.4
0.85
21
1.86
8.0
329
125
22.1
0.88
21
1.91
8.2
339
128
22.8
0.93
20
1.92
8.3
343
130
20.1
0.75
19
1.84
7.9
326
123
21.8
0.78
18
1.89
8.1
336
127
NOTE: Shaded area is ACCA (TVA) conditions
23.9
0.55
16
1.75
7.3
289
133
25.9
0.57
16
1.79
7.5
298
137
26.7
0.59
15
1.81
7.6
301
138
24.0
0.41
12
1.73
7.3
286
131
26.0
0.42
12
1.78
7.5
295
135
21.0
0.76
20
1.90
8.2
354
133
22.8
0.58
16
1.97
8.4
374
145
24.7
0.60
16
2.02
8.7
386
149
25.4
0.63
15
2.04
8.7
389
151
23.5
0.83
19
1.97
8.5
369
138
22.8
0.79
19
1.95
8.4
365
137
22.8
0.43
12
1.95
8.4
370
143
24.7
0.45
12
2.00
8.6
382
148
20.8
0.63
16
1.88
8.1
351
131
22.6
0.65
16
1.93
8.3
361
135
24.4
0.37
11
2.03
8.7
390
154
26.5
0.38
11
2.09
9.0
402
159
27.3
0.40
11
2.11
9.1
406
160
-
-
19.4
0.88
21
1.94
8.5
370
131
21.0
0.92
21
1.99
8.7
382
135
21.7
0.96
20
2.01
8.8
386
136
19.1
0.78
18
1.92
8.4
367
129
20.7
0.81
18
1.97
8.6
378
133
20.0
0.79
20
1.98
8.7
398
139
21.7
0.82
19
2.04
8.9
411
143
22.3
0.86
18
2.06
9.0
415
145
19.8
0.65
16
1.97
8.6
394
137
21.4
0.67
16
2.02
8.8
407
142
21.6
0.60
16
2.05
9.0
421
152
23.4
0.62
16
2.11
9.2
434
156
24.1
0.65
15
2.13
9.3
438
158
21.7
0.45
12
2.03
8.9
417
150
23.5
0.47
12
2.09
9.1
429
155
23.2
0.39
11
2.12
9.3
439
161
25.2
0.40
11
2.18
9.5
452
166
25.9
0.42
10
2.20
9.6
457
168
-
-
18.0
0.89
20
2.01
9.0
409
135
19.5
0.92
19
2.06
9.2
422
139
20.1
0.97
19
2.08
9.3
426
141
17.7
0.78
17
1.99
8.9
405
134
19.2
0.81
17
2.05
9.1
418
138
18.5
0.80
18
2.06
9.2
440
144
20.1
0.83
18
2.11
9.4
454
148
20.7
0.87
17
2.13
9.5
458
150
18.3
0.66
15
2.04
9.1
436
142
19.9
0.68
15
2.09
9.3
449
147
63
20.5
0.71
14
2.11
9.4
454
148
20.0
0.60
15
2.13
9.5
465
157
21.7
0.63
15
2.19
9.7
479
162
22.4
0.66
14
2.20
9.8
484
163
20.1
0.45
11
2.11
9.4
460
155
21.8
0.47
11
2.17
9.6
474
160
67
22.4
0.49
11
2.19
9.7
479
162
115
21.5
0.39
10
2.20
9.8
485
167
23.3
0.40
10
2.26
10.1
500
172
24.0
0.42
10
2.28
10.2
505
174
-
-
71
-
COOLING OPERATION
Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
24.1 25.0 27.4
23.5 24.4 26.7
23.0 23.8 26.1
22.4
23.2
25.5
21.3 22.1 24.2
19.7
S/T
0.74 0.62 0.43
0.77 0.64 0.45
0.79 0.66 0.46
0.82
0.68
0.47
0.85 0.71 0.49
0.85
Delta T
17
15
11
17
15
11
17
15
11
18
15
12
17
15
11
16
955
KW
1.57 1.60 1.66
1.70 1.73 1.79
1.81 1.85 1.91
1.91
1.95
2.02
1.99 2.04 2.11
2.06
AMPS
6.6
6.8
7.0
7.1
7.3
7.5
7.7
7.9
8.1
8.2
8.4
8.7
8.7
8.9
9.2
9.2
HI PR
233
251
265
262
282
298
298
321
338
339
365
386
382
411
434
422
LO PR
111
118
129
118
125
137
122
130
142
128
137
149
135
143
156
139
MODEL: GPC1424H41A*
COOLING PERFORMANCE DATA
GPC1424H41A*
13
14
EXPANDED PERFORMANCE DATA
85
80
22.4
0.85
24
1.54
6.5
229
109
25.4
0.97
24
1.61
6.8
241
115
24.6
0.93
25
1.60
6.8
238
114
22.7
0.89
25
1.56
6.6
231
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
850
745
955
850
745
23.2
0.86
25
1.59
6.7
249
117
25.1
0.89
24
1.63
6.9
256
121
25.9
0.94
23
1.64
7.0
259
122
22.8
0.80
23
1.58
6.7
246
116
24.8
0.83
22
1.62
6.8
254
120
24.3
0.78
23
1.64
6.9
263
128
26.3
0.81
23
1.69
7.1
271
132
27.1
0.85
22
1.70
7.2
273
133
24.4
0.65
20
1.63
6.9
260
127
26.4
0.67
19
1.67
7.1
268
131
25.9
0.63
20
1.70
7.2
274
136
28.1
0.65
20
1.74
7.4
282
140
28.9
0.69
19
1.76
7.4
285
142
26.1
0.49
16
1.68
7.1
271
135
28.3
0.50
15
1.73
7.3
279
139
22.2
0.93
25
1.68
7.1
259
116
24.1
0.96
25
1.72
7.3
267
120
24.8
1.00
24
1.74
7.3
270
121
21.8
0.88
24
1.67
7.0
257
115
23.7
0.92
23
1.71
7.2
265
119
22.6
0.89
25
1.72
7.2
279
124
24.5
0.93
25
1.76
7.4
288
128
25.3
0.97
24
1.78
7.5
290
129
22.3
0.83
23
1.70
7.2
276
123
24.2
0.86
22
1.75
7.4
285
126
23.7
0.81
24
1.78
7.5
295
135
25.7
0.84
23
1.82
7.7
304
139
26.5
0.88
22
1.84
7.7
307
141
23.8
0.67
20
1.76
7.4
292
134
25.8
0.70
20
1.81
7.6
301
138
25.3
0.65
20
1.84
7.7
307
144
27.4
0.68
20
1.89
7.9
317
148
28.2
0.71
19
1.90
8.0
320
150
25.5
0.50
16
1.82
7.7
304
143
27.6
0.52
16
1.87
7.9
314
147
21.7
0.95
25
1.79
7.7
295
121
23.5
0.98
25
1.84
7.9
304
125
24.2
1.00
23
1.86
7.9
307
126
21.3
0.91
24
1.78
7.6
292
120
23.1
0.94
23
1.82
7.8
301
123
22.1
0.92
25
1.83
7.8
317
129
24.0
0.95
25
1.88
8.0
327
133
24.7
1.00
24
1.90
8.1
330
134
21.8
0.85
23
1.82
7.8
314
127
NOTE:
23.6
0.88
22
1.87
8.0
324
131
27.0
0.54
16
2.00
8.5
357
153
22.5
0.97
24
1.92
8.3
343
130
23.0
0.91
23
1.97
8.5
369
138
24.6
0.74
20
2.04
8.8
390
151
26.3
0.55
16
2.11
9.1
406
160
23.2
0.83
24
1.90
8.1
335
141
25.1
0.86
23
1.95
8.3
345
145
25.8
0.90
22
1.96
8.4
349
146
24.7
0.67
20
1.96
8.4
349
150
26.8
0.70
20
2.01
8.6
360
154
27.6
0.73
19
2.03
8.7
364
156
21.2
0.98
26
1.89
8.1
336
127
22.9
1.00
25
1.94
8.4
346
131
23.6
1.00
23
1.96
8.4
350
132
21.6
0.95
25
1.93
8.3
361
135
23.4
0.98
25
1.99
8.6
373
139
24.1
1.00
23
2.00
8.6
376
141
22.6
0.85
24
2.00
8.6
382
148
24.5
0.88
23
2.05
8.8
393
152
25.2
0.93
23
2.07
8.9
397
154
24.1
0.69
21
2.07
8.9
398
157
26.1
0.72
20
2.13
9.1
410
162
26.9
0.75
19
2.14
9.2
414
164
23.3 24.9 20.8
21.3
22.7
24.3
0.69 0.52 0.93
0.88
0.71
0.53
20
16
24
23
20
16
1.88 1.94 1.87
1.92
1.98
2.05
8.0
8.3
8.1
8.3
8.5
8.8
332
346
332
358
378
394
139
148
126
134
146
156
Shaded area reflects AHRI rating conditions
25.2
0.72
20
1.93
8.2
342
143
20.1
1.00
25
1.97
8.6
378
133
21.8
1.00
24
2.03
8.9
389
137
22.4
1.00
22
2.04
8.9
393
139
19.8
0.97
24
1.96
8.6
374
132
21.4
1.00
23
2.01
8.8
386
136
20.5
0.98
25
2.02
8.8
407
142
22.2
1.00
24
2.07
9.1
419
146
22.9
1.00
22
2.09
9.2
423
148
20.2
0.91
23
2.00
8.8
403
140
21.9
0.94
22
2.06
9.0
415
145
21.5
0.89
23
2.09
9.1
429
155
23.3
0.92
23
2.15
9.4
443
159
24.0
0.96
22
2.16
9.5
447
161
21.6
0.74
20
2.07
9.0
425
153
23.4
0.77
19
2.13
9.3
438
158
* NOTE: Shaded area is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
24.2
0.88
23
1.58
6.7
236
112
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
22.9
0.72
20
2.16
9.4
448
165
24.8
0.75
20
2.22
9.7
462
170
25.6
0.78
19
2.24
9.8
466
172
23.1
0.55
16
2.14
9.4
443
163
25.0
0.57
16
2.20
9.6
457
168
18.6
1.00
23
2.05
9.1
417
138
20.2
1.00
22
2.10
9.4
430
142
20.8
1.00
20
2.12
9.5
435
143
18.3
0.98
22
2.03
9.0
413
136
19.8
1.00
21
2.08
9.3
426
141
19.0
0.99
23
2.09
9.3
449
147
20.6
1.00
22
2.15
9.6
463
151
21.2
1.00
20
2.17
9.7
468
153
18.7
0.92
21
2.07
9.3
445
145
20.3
0.95
21
2.13
9.5
458
150
63
20.9
1.00
20
2.15
9.6
463
151
19.9
0.89
22
2.17
9.6
474
160
21.5
0.93
22
2.22
9.9
489
165
22.2
0.97
21
2.24
10.0
494
167
20.0
0.75
18
2.15
9.6
470
158
21.6
0.77
18
2.21
9.8
484
163
67
22.3
0.81
17
2.22
9.9
489
165
115
21.2
0.72
19
2.24
10.0
495
170
23.0
0.75
19
2.30
10.3
510
176
23.7
0.79
18
2.32
10.4
515
177
21.4
0.56
15
2.22
9.9
490
169
23.1
0.58
14
2.28
10.2
505
174
71
23.8
0.61
14
2.30
10.3
510
176
COOLING OPERATION
Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
25.0 25.5 27.2 29.1 24.4 24.9 26.6 28.4 23.8 24.3 26.0 27.8 23.2
23.7
25.3
27.1 22.0 22.5 24.1 25.7 20.4
S/T
0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00
0.95
0.78
0.58 1.00 1.00 0.81 0.60 1.00
Delta T
22
21
19
15
23
22
19
15
23
22
19
15
22
22
19
15
21
22
19
15
20
955
KW
1.60 1.63 1.69 1.74 1.72 1.76 1.82 1.89 1.84 1.88 1.95 2.01 1.94
1.99
2.05
2.13 2.03 2.07 2.15 2.22 2.10
AMPS
6.8
6.9
7.1
7.4
7.3
7.4
7.7
7.9
7.9
8.0
8.3
8.6
8.4
8.6
8.8
9.1
8.9
9.1
9.4
9.7
9.4
HI PR
238
256
271
282
267
288
304
317
304
327
345
360
346
373
393
410
389
419
443
462
430
LO PR
114
121
132
140
120
128
139
148
125
133
145
154
131
139
152
162
137
146
159
170
142
MODEL: GPC1424H41A*
COOLING PERFORMANCE DATA
GPC1424H41A*
EXPANDED PERFORMANCE DATA
27.5
0.82
20
1.86
7.7
240
111
25.4
0.79
20
1.81
7.5
232
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1180
920
1050
28.3
0.86
19
1.88
7.8
242
113
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
920
28.3
0.74
18
1.90
7.9
258
119
26.1
0.71
19
1.85
7.7
250
115
29.1
0.77
18
1.92
7.9
260
120
25.8
0.58
15
1.84
7.6
248
114
30.6
0.56
15
1.96
8.1
272
129
28.3
0.54
15
1.92
7.9
264
126
31.5
0.58
14
1.98
8.2
275
131
28.3
0.40
11
1.90
7.8
261
124
32.9
0.36
10
2.03
8.4
284
138
30.3
0.35
10
1.98
8.2
275
134
33.9
0.38
10
2.05
8.5
287
139
-
26.8
0.85
20
2.01
8.3
269
118
24.8
0.82
20
1.96
8.1
261
114
27.6
0.90
19
2.03
8.3
272
119
24.4
0.72
18
1.94
8.0
258
113
27.6
0.76
18
2.06
8.5
289
125
25.5
0.74
19
2.00
8.2
281
121
28.5
0.80
18
2.07
8.5
292
126
25.2
0.61
15
1.99
8.2
278
120
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
24.9
0.70
17
1.80
7.4
230
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
32.1
0.37
10
2.20
9.0
319
146
29.6
0.36
11
2.14
8.8
309
141
33.1
0.39
10
2.22
9.1
322
147
-
26.2
0.88
20
2.14
8.9
306
122
24.2
0.84
20
2.09
8.7
297
119
27.0
0.92
19
2.16
9.0
309
124
23.8
0.74
18
2.07
8.6
294
117
27.0
0.78
19
2.19
9.1
329
130
24.9
0.76
19
2.14
8.9
319
126
27.8
0.82
18
2.21
9.2
332
131
24.6
0.62
15
2.12
8.8
316
125
29.2
0.59
15
2.27
9.4
347
142
26.9
0.57
15
2.21
9.2
337
138
30.1
0.62
15
2.29
9.5
351
143
27.0
0.43
12
2.19
9.1
334
136
31.3
0.38
10
2.34
9.8
362
151
28.9
0.37
11
2.28
9.5
351
147
32.3
0.40
10
2.36
9.8
366
153
-
25.6
0.90
20
2.26
9.5
348
128
23.6
0.87
21
2.20
9.3
338
125
26.3
0.95
19
2.28
9.6
352
130
23.2
0.77
18
2.18
9.2
334
123
NOTE: Shaded area is ACCA (TVA) conditions
29.9
0.58
15
2.12
8.7
305
137
27.6
0.56
15
2.07
8.5
296
133
30.8
0.61
15
2.14
8.8
309
138
27.7
0.42
12
2.05
8.4
293
131
28.5
0.61
15
2.39
10.0
396
149
26.3
0.59
16
2.33
9.8
384
145
29.3
0.64
15
2.41
10.1
400
151
27.1
0.85
18
2.33
9.8
378
138
26.3
0.81
19
2.31
9.7
375
137
24.3
0.78
19
2.25
9.5
363
133
26.3
0.44
12
2.31
9.7
380
143
24.0
0.64
15
2.23
9.4
360
131
30.6
0.39
11
2.47
10.4
413
159
28.2
0.38
11
2.41
10.1
400
154
31.5
0.41
10
2.49
10.5
417
161
-
24.3
0.94
20
2.36
10.1
392
135
22.4
0.90
20
2.30
9.8
380
131
25.0
0.98
19
2.38
10.2
396
136
22.0
0.80
18
2.28
9.7
376
129
25.0
0.84
18
2.41
10.3
422
143
23.1
0.81
19
2.35
10.1
409
139
25.8
0.88
18
2.43
10.4
426
145
22.8
0.66
15
2.33
10.0
405
138
27.1
0.64
15
2.50
10.7
445
156
25.0
0.61
15
2.43
10.4
432
152
27.9
0.67
14
2.52
10.7
450
158
25.0
0.46
12
2.41
10.3
427
150
29.0
0.41
10
2.58
11.0
464
167
26.8
0.39
11
2.52
10.7
450
162
29.9
0.43
10
2.61
11.1
469
168
-
22.5
0.95
19
2.44
10.7
433
139
20.8
0.91
19
2.38
10.4
420
135
23.2
0.99
18
2.47
10.8
437
141
20.4
0.80
16
2.36
10.3
416
134
23.2
0.85
17
2.50
10.9
466
148
21.4
0.82
17
2.44
10.6
452
144
23.9
0.89
16
2.52
11.0
470
150
21.2
0.67
14
2.41
10.5
447
142
63
23.6
0.73
13
2.50
10.9
466
148
22.9
0.70
14
2.48
10.8
461
147
25.1
0.64
14
2.59
11.3
492
162
23.1
0.62
14
2.52
11.0
477
157
25.8
0.67
14
2.61
11.4
497
163
23.2
0.46
11
2.50
10.9
472
155
67
25.9
0.50
10
2.59
11.3
492
162
25.1
0.48
11
2.56
11.2
487
160
115
26.9
0.41
10
2.68
11.7
513
172
24.8
0.40
10
2.61
11.4
498
167
27.7
0.43
9
2.70
11.8
518
174
-
71
-
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
27.8 28.8 31.6
27.2 28.2 30.9
26.5 27.5 30.1
25.9
26.8
29.4
24.6 25.5 27.9
22.8
S/T
0.76 0.63 0.44
0.79 0.66 0.46
0.81 0.67 0.47
0.83
0.70
0.48
0.87 0.72 0.50
0.87
Delta T
16
14
11
17
14
11
17
14
11
17
15
11
17
14
11
15
1180
KW
1.86 1.90 1.96
2.01 2.06 2.12
2.14 2.19 2.27
2.26
2.31
2.39
2.36 2.41 2.50
2.44
AMPS
7.7
7.9
8.1
8.3
8.5
8.7
8.9
9.1
9.4
9.5
9.7
10.0
10.1 10.3 10.7
10.7
HI PR
240
258
272
269
289
305
306
329
347
348
375
396
392
421
445
433
LO PR
111
119
129
118
125
137
122
130
142
128
137
149
135
143
156
139
MBh
27.0 28.0 30.7
26.4 27.4 30.0
25.8 26.7 29.3
25.1
26.1
28.5
23.9 24.7 27.1
22.1
S/T
0.73 0.61 0.42
0.75 0.63 0.43
0.77 0.64 0.45
0.80
0.66
0.46
0.83 0.69 0.48
0.83
Delta T
17
15
11
17
15
11
17
15
11
18
15
11
17
15
11
16
70
1050
KW
1.84 1.89 1.95
1.99 2.04 2.11
2.12 2.17 2.25
2.24
2.29
2.37
2.34 2.39 2.47
2.42
AMPS
7.6
7.8
8.0
8.2
8.4
8.6
8.9
9.1
9.3
9.4
9.6
10.0
10.0 10.2 10.6
10.6
HI PR
237
255
269
266
286
302
303
326
344
345
371
392
388
417
441
428
LO PR
110
117
128
117
124
135
121
129
141
127
135
148
133
142
155
138
MODEL: GPC1430H41A*
COOLING PERFORMANCE DATA
GPC1430H41A*
15
16
EXPANDED PERFORMANCE DATA
85
80
25.8
0.87
22
1.83
7.6
235
109
29.3
0.99
23
1.91
7.9
247
115
28.5
0.95
24
1.89
7.8
244
114
26.3
0.91
24
1.84
7.6
237
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1050
920
1180
1050
920
26.8
0.88
24
1.89
7.8
255
117
29.0
0.91
23
1.93
8.0
263
121
29.9
0.96
22
1.95
8.1
266
122
26.4
0.82
22
1.87
7.7
253
116
28.6
0.85
21
1.92
7.9
260
120
28.0
0.80
22
1.95
8.0
269
128
30.4
0.83
22
2.00
8.2
278
132
31.3
0.87
21
2.01
8.3
281
133
28.2
0.67
19
1.93
8.0
267
127
30.5
0.69
18
1.98
8.2
275
131
29.9
0.65
19
2.01
8.3
281
136
32.4
0.67
19
2.07
8.5
290
141
33.4
0.70
18
2.08
8.6
293
142
30.1
0.50
15
2.00
8.2
278
135
32.6
0.52
15
2.05
8.5
287
139
25.7
0.95
24
1.99
8.2
266
116
27.8
0.98
24
2.04
8.4
274
120
28.6
1.00
22
2.06
8.5
277
121
25.2
0.90
23
1.98
8.1
263
115
27.3
0.94
22
2.03
8.3
272
119
26.1
0.91
24
2.04
8.4
286
124
28.3
0.95
24
2.09
8.6
295
128
29.2
0.99
23
2.11
8.7
298
129
25.8
0.85
22
2.02
8.3
283
123
27.9
0.88
21
2.07
8.5
292
126
27.4
0.82
23
2.11
8.6
302
135
29.7
0.86
22
2.16
8.9
312
139
30.6
0.90
21
2.18
8.9
315
141
27.5
0.69
19
2.09
8.6
299
134
29.8
0.72
19
2.14
8.8
309
138
29.2
0.67
20
2.18
8.9
315
144
31.7
0.69
19
2.23
9.2
325
149
32.6
0.73
18
2.25
9.3
328
150
29.4
0.52
15
2.16
8.9
312
143
31.9
0.53
15
2.22
9.1
322
147
25.0
0.97
24
2.12
8.9
303
121
27.1
1.00
24
2.18
9.1
312
125
27.9
1.00
22
2.20
9.2
315
126
24.6
0.93
23
2.11
8.8
300
120
26.7
0.96
22
2.16
9.0
309
124
25.5
0.94
24
2.17
9.1
326
129
27.7
0.97
24
2.23
9.3
336
133
28.5
1.00
22
2.25
9.4
339
134
25.1
0.87
22
2.15
9.0
322
128
NOTE:
27.2
0.90
21
2.21
9.2
332
131
31.1
0.55
15
2.36
9.8
366
153
26.0
0.99
23
2.28
9.6
352
130
26.6
0.93
22
2.33
9.8
379
138
28.4
0.76
19
2.41
10.1
400
151
30.4
0.57
15
2.49
10.5
417
161
26.7
0.85
23
2.25
9.3
344
141
29.0
0.88
22
2.30
9.6
354
145
29.8
0.92
21
2.32
9.7
358
146
28.5
0.69
20
2.32
9.7
359
150
30.9
0.71
19
2.38
9.9
370
154
31.8
0.75
18
2.41
10.0
373
156
24.4
1.00
24
2.24
9.4
345
127
26.5
1.00
23
2.30
9.7
355
131
27.3
1.00
21
2.32
9.8
359
132
24.9
0.97
24
2.29
9.6
371
135
27.0
1.00
24
2.35
9.9
382
139
27.8
1.00
22
2.37
10.0
386
141
26.1
0.87
23
2.37
10.0
392
148
28.3
0.91
22
2.43
10.2
404
152
29.1
0.95
22
2.45
10.3
408
154
27.8
0.71
20
2.45
10.3
408
157
30.1
0.73
19
2.52
10.6
421
162
31.1
0.77
19
2.54
10.7
425
164
26.9 28.7 24.0
24.5
26.2
28.0
0.71 0.53 0.96
0.90
0.73
0.55
19
15
23
22
19
15
2.23 2.30 2.22
2.27
2.35
2.43
9.3
9.6
9.3
9.6
9.9
10.2
340
355
341
367
388
404
139
148
126
134
146
156
Shaded area reflects AHRI rating conditions
29.1
0.73
19
2.29
9.5
351
144
23.2
1.00
23
2.34
10.0
388
133
25.1
1.00
22
2.40
10.3
400
137
25.9
1.00
20
2.42
10.4
404
139
22.8
0.99
23
2.32
9.9
384
132
24.7
1.00
22
2.38
10.2
396
136
23.7
1.00
24
2.39
10.2
417
142
25.6
1.00
22
2.46
10.5
430
146
26.4
1.00
21
2.48
10.6
434
148
23.3
0.93
22
2.37
10.1
413
140
25.3
0.97
21
2.43
10.4
426
145
24.8
0.91
22
2.47
10.6
441
155
26.8
0.94
22
2.54
10.8
454
160
27.7
0.99
21
2.56
10.9
459
161
24.9
0.76
19
2.45
10.5
436
153
27.0
0.79
19
2.52
10.7
450
158
* NOTE: Shaded area is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
28.0
0.90
22
1.88
7.8
242
113
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
26.4
0.73
19
2.56
10.9
459
165
28.6
0.76
19
2.63
11.2
474
170
29.5
0.80
18
2.65
11.3
478
172
26.6
0.57
15
2.54
10.8
455
163
28.8
0.59
15
2.61
11.1
469
168
21.5
1.00
21
2.42
10.6
428
138
23.3
1.00
20
2.49
10.9
442
142
24.0
1.00
19
2.51
10.9
446
144
21.1
1.00
21
2.40
10.5
424
136
22.9
1.00
20
2.47
10.8
437
141
21.9
1.00
22
2.48
10.8
461
147
23.7
1.00
21
2.55
11.1
475
151
24.5
1.00
19
2.57
11.2
480
153
21.6
0.94
20
2.46
10.7
456
145
23.4
0.97
20
2.52
11.0
470
150
63
24.1
1.00
19
2.55
11.1
475
151
23.0
0.91
21
2.56
11.2
487
160
24.9
0.95
21
2.63
11.5
502
165
25.6
0.99
20
2.66
11.6
507
167
23.1
0.76
18
2.54
11.1
482
159
25.0
0.79
17
2.61
11.4
497
163
67
25.7
0.83
17
2.63
11.5
502
165
115
24.5
0.74
18
2.65
11.6
508
171
26.5
0.77
18
2.73
11.9
523
176
27.3
0.81
17
2.75
12.0
529
178
24.7
0.57
14
2.63
11.5
503
169
26.7
0.59
14
2.70
11.8
518
174
71
27.5
0.62
13
2.73
11.9
523
176
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
28.8 29.4 31.4 33.6 28.1 28.7 30.7 32.8 27.5 28.1 30.0 32.1 26.8
27.4
29.3
31.3 25.5 26.0 27.8 29.7 23.6
S/T
0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00
1.00
0.79
0.59 1.00 1.00 0.82 0.62 1.00
Delta T
21
20
18
14
22
21
18
14
21
21
18
14
21
21
18
14
20
20
18
14
18
1180
KW
1.89 1.93 2.00 2.07 2.04 2.09 2.16 2.23 2.18 2.23 2.30 2.38 2.30
2.35
2.43
2.52 2.40 2.46 2.54 2.63 2.49
AMPS
7.8
8.0
8.2
8.5
8.4
8.6
8.9
9.2
9.1
9.3
9.6
9.9
9.7
9.9
10.2
10.6 10.3 10.5 10.8 11.2 10.9
HI PR
244
263
278
290
274
295
312
325
312
336
354
370
355
382
404
421
400
430
454
474
442
LO PR
114
121
132
141
120
128
139
149
125
133
145
154
131
139
152
162
137
146
160
170
142
MODEL: GPC1430H41A*
COOLING PERFORMANCE DATA
GPC1430H41A*
EXPANDED PERFORMANCE DATA
34.4
0.83
22
2.33
10.5
238
107
31.8
0.80
22
2.27
10.3
231
104
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1349
1052
1200
35.5
0.87
21
2.35
10.6
241
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1052
35.5
0.74
20
2.38
10.8
256
114
32.7
0.71
20
2.32
10.5
249
111
36.5
0.77
19
2.40
10.8
259
116
32.4
0.58
17
2.30
10.4
246
110
38.4
0.56
16
2.45
11.0
271
125
35.4
0.54
17
2.39
10.8
263
121
39.5
0.59
16
2.47
11.1
273
126
35.5
0.41
13
2.37
10.7
260
120
41.2
0.36
11
2.54
11.4
282
133
38.0
0.35
12
2.47
11.1
274
129
42.4
0.38
11
2.56
11.5
285
134
-
33.6
0.86
22
2.51
11.3
267
114
31.1
0.83
22
2.45
11.0
259
110
34.7
0.90
21
2.53
11.3
270
115
30.5
0.73
19
2.43
10.9
257
109
34.6
0.77
20
2.57
11.5
288
121
32.0
0.74
21
2.50
11.2
279
117
35.7
0.80
20
2.59
11.6
290
122
31.6
0.61
17
2.48
11.1
276
116
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
31.3
0.70
19
2.25
10.2
229
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
40.2
0.37
11
2.74
12.2
317
140
37.1
0.36
12
2.67
11.9
307
136
41.4
0.39
11
2.76
12.3
320
142
-
32.8
0.88
22
2.67
12.1
304
118
30.3
0.85
22
2.60
11.8
295
114
33.8
0.92
21
2.69
12.2
307
119
29.8
0.74
19
2.58
11.7
292
113
33.8
0.78
20
2.73
12.3
327
126
31.2
0.76
21
2.66
12.0
317
122
34.8
0.82
20
2.75
12.4
330
127
30.9
0.62
17
2.64
11.9
314
121
36.6
0.59
17
2.82
12.7
345
137
33.8
0.57
17
2.75
12.4
335
133
37.7
0.62
16
2.84
12.8
349
138
33.8
0.43
13
2.73
12.3
332
132
39.3
0.38
11
2.92
13.1
360
146
36.3
0.37
12
2.84
12.8
349
142
40.5
0.40
11
2.94
13.2
364
147
-
32.0
0.91
22
2.81
12.8
346
124
29.6
0.87
23
2.74
12.5
336
120
33.0
0.95
21
2.84
12.9
350
125
29.1
0.77
20
2.72
12.4
332
119
NOTE: Shaded area is ACCA (TVA) conditions
37.5
0.58
17
2.65
11.8
304
132
34.6
0.56
17
2.58
11.5
295
128
38.6
0.61
16
2.67
11.9
307
133
34.7
0.42
13
2.56
11.4
292
127
35.7
0.61
17
2.97
13.4
393
144
33.0
0.59
17
2.90
13.1
382
140
36.8
0.64
16
3.00
13.5
397
145
34.0
0.85
20
2.90
13.2
376
133
33.0
0.81
20
2.88
13.1
373
132
30.4
0.78
21
2.80
12.7
361
128
33.0
0.44
13
2.87
13.0
378
138
30.1
0.64
17
2.78
12.6
358
127
38.3
0.39
12
3.07
13.9
410
153
35.4
0.38
12
2.99
13.5
398
149
39.5
0.41
11
3.10
14.0
414
155
-
30.4
0.94
22
2.93
13.5
389
130
28.1
0.91
22
2.86
13.2
378
126
31.4
0.99
21
2.96
13.6
393
131
27.6
0.80
19
2.84
13.1
374
125
31.3
0.84
20
3.00
13.8
419
138
28.9
0.81
21
2.92
13.4
407
134
32.3
0.88
19
3.03
13.9
423
140
28.6
0.67
17
2.90
13.3
402
133
33.9
0.64
17
3.10
14.2
443
151
31.3
0.61
17
3.02
13.8
429
146
34.9
0.67
16
3.13
14.3
447
152
31.4
0.46
13
3.00
13.7
425
145
36.4
0.41
11
3.21
14.7
462
161
33.6
0.39
12
3.12
14.3
448
156
37.5
0.43
11
3.24
14.8
466
162
-
28.2
0.95
20
3.04
14.2
430
134
26.0
0.91
21
2.96
13.8
417
130
29.0
0.99
20
3.06
14.3
435
136
25.6
0.80
18
2.94
13.7
413
129
29.0
0.85
19
3.11
14.5
463
143
26.8
0.82
19
3.03
14.1
449
139
29.9
0.89
18
3.13
14.6
468
144
26.5
0.67
16
3.00
14.0
445
137
63
29.6
0.73
15
3.11
14.5
463
143
28.7
0.70
15
3.08
14.4
458
142
31.4
0.64
15
3.21
14.9
489
156
29.0
0.62
16
3.13
14.6
474
151
32.4
0.67
15
3.24
15.1
494
158
29.1
0.47
12
3.10
14.4
470
150
67
32.4
0.51
11
3.21
14.9
489
156
31.5
0.48
12
3.18
14.8
484
155
115
33.7
0.41
11
3.32
15.4
510
166
31.1
0.40
11
3.24
15.0
495
161
34.7
0.43
10
3.35
15.6
515
168
-
71
-
COOLING OPERATION
Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
34.9 36.2 39.6
34.1 35.3 38.7
33.3 34.5 37.8
32.5
33.6
36.9
30.8 32.0 35.0
28.6
S/T
0.76 0.64 0.44
0.79 0.66 0.46
0.81 0.68 0.47
0.84
0.70
0.48
0.87 0.72 0.50
0.87
Delta T
18
16
12
18
16
12
18
16
12
18
16
12
18
16
12
17
1349
KW
2.33 2.38 2.45
2.51 2.57 2.65
2.67 2.73 2.82
2.81
2.88
2.97
2.93 3.00 3.10
3.04
AMPS
10.5 10.8 11.0
11.3 11.5 11.8
12.1 12.3 12.7
12.8
13.1
13.4
13.5 13.8 14.2
14.2
HI PR
238
256
271
267
288
304
304
327
345
346
372
393
389
419
442
430
LO PR
107
114
125
114
121
132
118
126
137
124
132
144
130
138
151
134
MBh
33.9 35.1 38.5
33.1 34.3 37.6
32.3 33.5 36.7
31.5
32.7
35.8
29.9 31.0 34.0
27.7
S/T
0.73 0.61 0.42
0.75 0.63 0.44
0.77 0.64 0.45
0.80
0.67
0.46
0.83 0.69 0.48
0.83
Delta T
19
16
12
19
17
13
19
17
13
19
17
13
19
16
12
18
70
1200
KW
2.31 2.36 2.43
2.49 2.54 2.63
2.65 2.71 2.80
2.79
2.85
2.95
2.91 2.97 3.07
3.01
AMPS
10.5 10.7 11.0
11.2 11.4 11.7
12.0 12.2 12.6
12.7
12.9
13.3
13.4 13.7 14.1
14.1
HI PR
236
254
268
265
285
301
301
324
342
343
369
389
386
415
438
426
LO PR
106
113
124
112
120
131
117
124
136
123
131
143
129
137
149
133
MODEL: GPC1436H41A*
COOLING PERFORMANCE DATA
GPC1436H41A*
17
18
EXPANDED PERFORMANCE DATA
85
80
32.4
0.87
25
2.29
10.4
233
105
36.7
1.00
25
2.39
10.8
245
111
35.7
0.95
26
2.37
10.7
243
110
32.9
0.92
26
2.31
10.5
236
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1200
1052
1349
1200
1052
33.6
0.88
26
2.36
10.7
254
113
36.4
0.92
26
2.42
10.9
261
117
37.4
0.96
25
2.44
11.0
264
118
33.1
0.82
24
2.34
10.6
251
112
35.8
0.85
23
2.40
10.8
259
116
35.1
0.80
24
2.43
11.0
268
124
38.1
0.83
24
2.50
11.2
276
127
39.2
0.87
23
2.52
11.3
279
129
35.3
0.67
21
2.41
10.9
265
122
38.3
0.69
20
2.48
11.1
273
126
37.5
0.65
21
2.51
11.3
279
132
40.6
0.67
21
2.58
11.6
288
136
41.8
0.70
20
2.60
11.7
291
137
37.8
0.50
16
2.49
11.2
277
130
40.9
0.52
16
2.56
11.5
285
134
32.2
0.95
27
2.49
11.2
264
112
34.8
0.98
26
2.55
11.4
273
116
35.9
1.00
24
2.57
11.5
275
117
31.6
0.90
25
2.47
11.1
262
111
34.2
0.94
25
2.53
11.3
270
115
32.8
0.92
26
2.54
11.4
285
120
35.5
0.95
26
2.61
11.7
293
123
36.6
1.00
25
2.63
11.8
296
124
32.3
0.85
24
2.52
11.3
282
118
35.0
0.88
24
2.59
11.6
290
122
34.3
0.83
25
2.63
11.7
301
131
37.2
0.86
24
2.69
12.0
310
135
38.3
0.90
23
2.72
12.1
313
136
34.5
0.69
21
2.60
11.6
298
129
37.4
0.72
21
2.67
11.9
307
133
36.6
0.67
21
2.71
12.1
313
139
39.7
0.70
21
2.78
12.4
323
143
40.9
0.73
20
2.81
12.5
326
145
36.9
0.52
17
2.69
12.0
310
138
40.0
0.54
16
2.76
12.3
320
142
31.4
0.97
27
2.65
12.0
301
117
34.0
1.00
26
2.72
12.3
310
120
35.0
1.00
24
2.74
12.4
313
122
30.9
0.93
25
2.63
11.9
298
116
33.4
0.96
25
2.69
12.2
307
119
32.0
0.94
26
2.71
12.2
324
124
34.7
0.97
26
2.78
12.5
334
128
35.7
1.00
24
2.80
12.6
337
129
31.5
0.87
24
2.68
12.1
320
123
NOTE:
34.2
0.90
24
2.75
12.4
330
127
39.0
0.55
16
2.94
13.2
364
147
32.6
0.99
25
2.84
12.9
350
125
33.3
0.93
24
2.90
13.2
376
133
35.6
0.76
21
3.00
13.5
397
145
38.1
0.57
17
3.10
14.0
414
155
33.5
0.85
25
2.80
12.6
342
136
36.3
0.88
24
2.87
12.9
352
140
37.4
0.92
23
2.89
13.0
356
141
35.8
0.69
21
2.89
13.0
356
144
38.7
0.71
21
2.97
13.3
368
149
39.9
0.75
20
2.99
13.4
371
150
30.6
1.00
27
2.79
12.7
343
123
33.2
1.00
25
2.86
13.0
353
126
34.2
1.00
23
2.89
13.1
357
128
31.2
0.97
26
2.85
12.9
369
131
33.8
1.00
26
2.93
13.3
380
135
34.8
1.00
24
2.95
13.4
384
136
32.7
0.87
25
2.95
13.3
389
142
35.4
0.91
25
3.02
13.6
401
147
36.5
0.95
24
3.05
13.8
405
148
34.9
0.71
22
3.05
13.8
406
152
37.8
0.74
21
3.13
14.1
419
156
38.9
0.77
20
3.15
14.2
423
158
33.7 36.0 30.1
30.8
32.9
35.1
0.71 0.53 0.96
0.90
0.73
0.55
21
17
25
24
21
17
2.77 2.87 2.77
2.83
2.92
3.02
12.5 12.9 12.6
12.8
13.2
13.6
338
353
339
365
385
402
134
143
121
129
141
150
Shaded area reflects AHRI rating conditions
36.5
0.73
21
2.84
12.8
349
138
29.1
1.00
25
2.91
13.4
385
129
31.5
1.00
24
2.98
13.7
397
133
32.5
1.00
22
3.01
13.8
401
134
28.6
0.99
25
2.88
13.3
382
127
31.0
1.00
24
2.96
13.6
393
131
29.7
1.00
26
2.97
13.7
415
137
32.1
1.00
25
3.05
14.0
428
141
33.1
1.00
23
3.08
14.1
432
142
29.2
0.93
24
2.95
13.6
411
135
31.7
0.97
23
3.03
13.9
423
140
31.1
0.91
25
3.07
14.1
438
149
33.7
0.94
24
3.15
14.4
451
154
34.7
0.99
23
3.18
14.5
456
155
31.2
0.76
21
3.05
14.0
434
148
33.8
0.79
20
3.13
14.3
447
152
* NOTE: Shaded areas is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
35.1
0.91
24
2.35
10.6
241
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
33.1
0.74
21
3.18
14.5
457
159
35.9
0.76
21
3.26
14.9
471
164
37.0
0.80
20
3.29
15.0
476
166
33.4
0.57
17
3.15
14.4
452
157
36.2
0.59
16
3.24
14.8
466
162
26.9
1.00
24
3.01
14.1
426
133
29.2
1.00
22
3.09
14.4
439
137
30.1
1.00
21
3.12
14.5
443
138
26.5
1.00
23
2.99
14.0
422
132
28.7
1.00
22
3.06
14.3
435
136
27.5
1.00
24
3.08
14.4
458
141
29.8
1.00
23
3.16
14.7
472
146
30.7
1.00
21
3.19
14.9
477
147
27.1
0.94
22
3.05
14.3
454
140
29.3
0.97
22
3.13
14.6
468
144
63
30.2
1.00
21
3.16
14.7
472
146
28.8
0.92
23
3.18
14.8
484
154
31.2
0.95
23
3.27
15.2
499
159
32.1
1.00
22
3.30
15.3
504
161
28.9
0.77
19
3.16
14.7
479
153
31.3
0.79
19
3.24
15.1
494
158
67
32.3
0.83
18
3.27
15.2
499
159
115
30.7
0.74
20
3.29
15.3
505
165
33.3
0.77
20
3.38
15.7
520
170
34.3
0.81
19
3.41
15.8
525
171
30.9
0.57
15
3.26
15.2
500
163
33.5
0.59
15
3.35
15.6
515
168
71
34.5
0.62
15
3.38
15.7
520
170
COOLING OPERATION
Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
36.1 36.9 39.4 42.1 35.3 36.0 38.5 41.2 34.4 35.2 37.6 40.2 33.6
34.3
36.7
39.2 31.9 32.6 34.8 37.2 29.6
S/T
0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00
1.00
0.80
0.59 1.00 1.00 0.83 0.62 1.00
Delta T
23
22
19
16
24
23
20
16
23
23
20
16
23
23
20
16
22
22
20
16
20
1349
KW
2.37 2.42 2.50 2.58 2.55 2.61 2.69 2.78 2.72 2.78 2.87 2.97 2.86
2.93
3.02
3.13 2.98 3.05 3.15 3.26 3.09
AMPS
10.7 10.9 11.2 11.6 11.4 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.0
13.3
13.6
14.1 13.7 14.0 14.4 14.9 14.4
HI PR
243
261
276
288
273
293
310
323
310
334
352
368
353
380
401
419
397
428
451
471
439
LO PR
110
117
127
136
116
123
135
143
120
128
140
149
126
135
147
156
133
141
154
164
137
MODEL: GPC1436H41A*
COOLING PERFORMANCE DATA
GPC1436H41A*
EXPANDED PERFORMANCE DATA
39.2
0.81
23
2.54
11.6
236
110
36.2
0.79
23
2.48
11.3
229
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1461
1139
1300
40.4
0.85
22
2.56
11.7
238
111
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1139
40.3
0.73
21
2.60
11.8
254
117
37.2
0.70
21
2.53
11.5
246
113
41.6
0.76
20
2.62
11.9
257
118
36.9
0.58
17
2.51
11.4
244
112
43.7
0.55
17
2.68
12.1
268
127
40.3
0.53
17
2.62
11.9
260
123
45.0
0.58
16
2.70
12.2
271
128
40.4
0.40
13
2.59
11.8
258
122
46.9
0.35
12
2.77
12.5
280
135
43.3
0.34
12
2.70
12.2
271
131
48.3
0.37
11
2.79
12.6
283
137
-
38.3
0.84
23
2.74
12.4
265
116
35.3
0.81
23
2.67
12.1
257
112
39.4
0.88
22
2.77
12.5
268
117
34.7
0.72
20
2.65
12.0
254
111
39.4
0.75
21
2.80
12.6
285
123
36.4
0.73
21
2.73
12.3
277
119
40.6
0.79
20
2.83
12.7
288
124
36.0
0.60
17
2.71
12.2
274
118
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
35.6
0.69
20
2.46
11.2
227
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
45.8
0.37
12
2.99
13.4
314
143
42.3
0.35
12
2.92
13.1
305
139
47.2
0.39
11
3.02
13.5
317
145
-
37.4
0.87
23
2.92
13.3
301
120
34.5
0.83
23
2.85
13.0
292
117
38.5
0.91
22
2.94
13.4
304
121
33.9
0.73
20
2.82
12.9
289
115
38.5
0.77
21
2.98
13.6
324
128
35.5
0.75
21
2.91
13.3
314
124
39.6
0.81
20
3.01
13.7
327
129
35.1
0.61
17
2.88
13.2
311
123
41.6
0.59
17
3.08
14.0
342
140
38.4
0.56
18
3.00
13.7
332
135
42.9
0.61
17
3.11
14.1
346
141
38.5
0.42
13
2.98
13.5
329
134
44.7
0.38
12
3.19
14.5
357
149
41.2
0.36
12
3.11
14.1
346
144
46.0
0.40
11
3.21
14.6
361
150
-
36.5
0.89
23
3.07
14.1
343
126
33.6
0.86
23
3.00
13.8
333
123
37.5
0.94
22
3.10
14.2
347
128
33.1
0.76
20
2.97
13.7
329
121
NOTE: Shaded area is ACCA (TVA) conditions
42.7
0.57
17
2.89
13.0
301
134
39.4
0.55
18
2.82
12.7
292
130
43.9
0.60
17
2.92
13.1
304
136
39.4
0.41
13
2.80
12.6
289
129
40.6
0.60
17
3.25
14.9
390
147
37.5
0.58
18
3.17
14.5
378
142
41.8
0.63
17
3.28
15.0
394
148
38.7
0.84
20
3.17
14.5
373
136
37.5
0.80
21
3.14
14.4
369
134
34.6
0.77
22
3.06
14.1
358
130
37.6
0.44
13
3.14
14.4
374
141
34.3
0.63
18
3.04
14.0
355
129
43.6
0.39
12
3.36
15.4
407
156
40.2
0.38
12
3.27
15.0
394
152
44.9
0.41
12
3.39
15.5
411
158
-
34.6
0.93
23
3.21
14.9
386
132
32.0
0.89
23
3.13
14.6
374
128
35.7
0.97
22
3.23
15.1
390
134
31.4
0.79
20
3.10
14.4
371
127
35.7
0.83
21
3.28
15.3
415
141
32.9
0.80
21
3.20
14.9
403
137
36.7
0.87
20
3.31
15.4
420
142
32.6
0.66
17
3.17
14.8
399
135
38.6
0.63
17
3.39
15.7
439
154
35.6
0.61
17
3.30
15.3
425
149
39.7
0.66
16
3.42
15.8
443
155
35.7
0.46
13
3.27
15.2
421
148
41.4
0.40
12
3.51
16.3
458
164
38.2
0.39
12
3.42
15.8
444
159
42.7
0.42
11
3.54
16.4
462
165
-
32.1
0.93
21
3.32
15.7
427
137
29.6
0.90
22
3.24
15.3
414
133
33.0
0.98
20
3.35
15.9
431
138
29.1
0.79
19
3.21
15.2
410
131
33.0
0.84
20
3.40
16.1
459
146
30.5
0.81
20
3.31
15.7
445
141
34.0
0.88
19
3.43
16.2
464
147
30.2
0.66
16
3.28
15.5
441
140
63
33.7
0.72
15
3.40
16.1
459
146
32.7
0.69
16
3.37
15.9
454
144
35.7
0.63
16
3.51
16.6
485
159
33.0
0.61
16
3.42
16.1
470
154
36.8
0.66
15
3.54
16.7
490
161
33.1
0.46
12
3.39
16.0
465
153
67
36.9
0.50
12
3.51
16.6
485
159
35.8
0.48
12
3.48
16.4
480
157
115
38.4
0.41
11
3.63
17.1
506
169
35.4
0.39
11
3.54
16.7
490
164
39.5
0.43
11
3.66
17.3
511
171
-
71
-
COOLING OPERATION
Design Subcooling, 8 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
39.7 41.1 45.1
38.8 40.2 44.0
37.8 39.2 43.0
36.9
38.3
41.9
35.1 36.4 39.8
32.5
S/T
0.75 0.63 0.43
0.78 0.65 0.45
0.80 0.67 0.46
0.82
0.69
0.48
0.86 0.71 0.49
0.86
Delta T
19
16
12
19
16
12
19
16
12
19
17
13
19
16
12
18
1461
KW
2.54 2.60 2.68
2.74 2.80 2.89
2.92 2.98 3.08
3.07
3.14
3.25
3.21 3.28 3.39
3.32
AMPS
11.6 11.8 12.1
12.4 12.6 13.0
13.3 13.6 14.0
14.1
14.4
14.9
14.9 15.3 15.7
15.7
HI PR
236
254
268
265
285
301
301
324
342
343
369
390
386
415
439
426
LO PR
110
116
127
116
123
134
120
128
140
126
134
147
132
141
154
137
MBh
38.5 39.9 43.8
37.6 39.0 42.7
36.7 38.1 41.7
35.8
37.1
40.7
34.1 35.3 38.7
31.5
S/T
0.72 0.60 0.41
0.74 0.62 0.43
0.76 0.64 0.44
0.79
0.66
0.45
0.82 0.68 0.47
0.82
Delta T
20
17
13
20
17
13
20
17
13
20
17
13
20
17
13
18
70
1300
KW
2.52 2.58 2.66
2.72 2.78 2.87
2.89 2.96 3.06
3.05
3.12
3.22
3.18 3.25 3.36
3.29
AMPS
11.5 11.7 12.0
12.3 12.5 12.9
13.2 13.5 13.9
14.0
14.3
14.7
14.8 15.1 15.6
15.6
HI PR
234
251
266
262
282
298
298
321
339
340
366
386
382
411
434
422
LO PR
108
115
126
115
122
133
119
127
138
125
133
145
131
139
152
136
MODEL: GPC1442H41A*
COOLING PERFORMANCE DATA
GPC1442H41A*
19
20
EXPANDED PERFORMANCE DATA
85
80
36.8
0.86
26
2.50
11.4
231
107
41.8
0.98
26
2.61
11.8
243
113
40.6
0.94
27
2.58
11.8
241
112
37.5
0.90
27
2.52
11.5
234
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1300
1139
1461
1300
1139
38.2
0.87
27
2.58
11.7
251
115
41.4
0.90
26
2.64
12.0
259
119
42.6
0.95
25
2.66
12.1
262
120
37.6
0.81
25
2.56
11.6
249
114
40.8
0.84
24
2.62
11.9
257
118
40.0
0.79
25
2.66
12.0
265
126
43.3
0.82
25
2.73
12.3
274
130
44.6
0.85
24
2.75
12.4
276
131
40.2
0.66
21
2.64
12.0
263
125
43.5
0.68
21
2.70
12.2
271
128
42.7
0.64
22
2.75
12.4
277
134
46.2
0.66
22
2.82
12.7
285
138
47.6
0.69
21
2.84
12.8
288
140
43.0
0.49
17
2.72
12.3
274
133
46.5
0.51
17
2.79
12.6
283
137
36.6
0.94
28
2.72
12.3
262
115
39.6
0.97
27
2.79
12.6
270
118
40.8
1.00
26
2.81
12.7
273
119
36.0
0.89
26
2.70
12.2
260
113
39.0
0.93
25
2.77
12.5
268
117
37.3
0.90
27
2.78
12.5
282
122
40.4
0.94
27
2.85
12.8
291
126
41.6
0.98
26
2.87
12.9
294
127
36.7
0.84
25
2.76
12.4
279
121
39.8
0.87
24
2.83
12.7
288
124
39.1
0.81
26
2.87
12.9
298
133
42.3
0.85
25
2.94
13.2
307
137
43.6
0.89
24
2.97
13.3
310
138
39.3
0.68
22
2.85
12.8
295
132
42.5
0.71
21
2.92
13.1
304
136
41.7
0.66
22
2.97
13.3
311
142
45.1
0.69
22
3.04
13.6
320
146
46.5
0.72
21
3.07
13.8
324
147
42.0
0.51
17
2.94
13.2
308
140
45.5
0.53
17
3.02
13.5
317
145
35.7
0.96
28
2.89
13.2
298
119
38.7
1.00
27
2.97
13.5
307
123
39.9
1.00
25
2.99
13.6
310
124
35.1
0.92
26
2.87
13.1
295
118
38.0
0.95
26
2.94
13.4
304
121
36.4
0.93
27
2.96
13.5
321
127
39.4
0.96
27
3.03
13.8
331
131
40.6
1.00
26
3.06
13.9
334
132
35.9
0.86
25
2.93
13.4
318
125
NOTE:
38.9
0.89
24
3.01
13.7
327
129
44.4
0.54
17
3.21
14.6
361
150
37.1
0.98
26
3.10
14.2
347
128
37.9
0.92
25
3.17
14.5
373
136
40.5
0.75
21
3.28
15.0
394
148
43.3
0.56
17
3.39
15.5
411
158
38.1
0.84
26
3.06
13.9
339
138
41.3
0.87
25
3.14
14.2
349
142
42.5
0.91
24
3.16
14.3
353
144
40.7
0.68
22
3.16
14.3
353
147
44.1
0.70
22
3.24
14.7
364
152
45.4
0.74
21
3.27
14.8
368
153
34.8
0.99
28
3.05
14.0
340
125
37.7
1.00
27
3.13
14.4
350
129
38.9
1.00
24
3.15
14.5
354
130
35.5
0.96
27
3.12
14.3
365
133
38.5
0.99
27
3.20
14.7
377
137
39.6
1.00
25
3.22
14.8
380
138
37.2
0.86
26
3.22
14.7
386
145
40.3
0.89
25
3.30
15.1
398
150
41.5
0.94
24
3.33
15.2
402
151
39.7
0.70
22
3.33
15.2
402
155
43.0
0.73
22
3.42
15.6
415
159
44.3
0.76
21
3.45
15.7
419
161
38.3 41.0 34.2
35.0
37.4
40.0
0.70 0.52 0.94
0.89
0.72
0.54
22
17
26
25
22
17
3.03 3.13 3.02
3.09
3.19
3.30
13.8 14.2 13.9
14.2
14.6
15.1
335
350
336
362
382
398
137
146
124
132
144
153
Shaded area reflects AHRI rating conditions
41.5
0.72
21
3.11
14.1
346
141
33.1
1.00
27
3.18
14.8
382
131
35.9
1.00
25
3.26
15.2
394
135
36.9
1.00
23
3.29
15.3
398
136
32.5
0.98
26
3.15
14.7
378
130
35.2
1.00
25
3.23
15.1
390
134
33.7
0.99
27
3.25
15.1
411
139
36.6
1.00
26
3.34
15.5
424
144
37.6
1.00
24
3.36
15.6
428
145
33.2
0.92
25
3.22
15.0
407
138
36.0
0.95
24
3.31
15.4
420
142
35.3
0.90
26
3.36
15.6
434
152
38.3
0.93
25
3.45
16.0
448
157
39.4
0.97
24
3.48
16.1
452
158
35.5
0.75
21
3.33
15.4
430
151
38.5
0.78
21
3.42
15.8
443
155
* NOTE: Shaded areas is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
39.9
0.89
25
2.56
11.7
238
111
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
37.7
0.73
22
3.48
16.1
453
162
40.8
0.75
22
3.57
16.5
467
167
42.1
0.79
21
3.60
16.7
471
169
38.0
0.56
17
3.45
16.0
448
160
41.1
0.58
17
3.54
16.4
462
165
30.7
1.00
25
3.29
15.6
422
136
33.2
1.00
23
3.38
16.0
435
140
34.2
1.00
22
3.41
16.1
439
141
30.1
0.99
24
3.26
15.5
418
134
32.6
1.00
23
3.35
15.9
431
138
31.3
1.00
25
3.37
15.9
454
144
33.9
1.00
24
3.46
16.3
468
149
34.9
1.00
22
3.49
16.5
473
150
30.8
0.93
23
3.34
15.8
450
143
33.4
0.96
23
3.43
16.2
464
147
63
34.4
1.00
22
3.46
16.3
468
149
32.7
0.90
24
3.48
16.4
480
157
35.5
0.94
23
3.57
16.8
494
162
36.5
0.98
23
3.60
17.0
499
164
32.9
0.75
20
3.45
16.3
475
156
35.6
0.78
20
3.54
16.7
490
161
67
36.7
0.82
19
3.57
16.8
494
162
115
34.9
0.73
21
3.60
17.0
500
168
37.8
0.76
20
3.70
17.4
516
173
39.0
0.80
20
3.73
17.6
521
175
35.2
0.56
16
3.57
16.8
495
166
38.1
0.59
16
3.67
17.3
511
171
71
39.2
0.61
15
3.70
17.4
516
173
COOLING OPERATION
Design Subcooling, 8 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2
39.0
41.7
44.6 36.3 37.1 39.6 42.4 33.6
S/T
0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.93 0.76 0.57 1.00
0.96
0.78
0.59 1.00 1.00 0.81 0.61 1.00
Delta T
24
23
20
16
25
23
20
16
25
24
20
16
24
24
21
16
23
23
20
16
21
1461
KW
2.58 2.64 2.73 2.82 2.79 2.85 2.94 3.04 2.97 3.03 3.14 3.24 3.13
3.20
3.30
3.42 3.26 3.34 3.45 3.57 3.38
AMPS
11.8 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.5 13.8 14.2 14.7 14.4
14.7
15.1
15.6 15.2 15.5 16.0 16.5 16.0
HI PR
241
259
274
285
270
291
307
320
307
331
349
364
350
377
398
415
394
424
448
467
435
LO PR
112
119
130
138
118
126
137
146
123
131
142
152
129
137
150
159
135
144
157
167
140
MODEL: GPC1442H41A*
COOLING PERFORMANCE DATA
GPC1442H41A*
EXPANDED PERFORMANCE DATA
45.0
0.83
21
2.94
12.7
236
110
41.5
0.80
22
2.87
12.4
229
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1800
1400
1600
46.3
0.87
21
2.97
12.8
238
112
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
46.3
0.74
20
3.01
13.0
254
118
42.8
0.71
20
2.93
12.7
246
114
47.7
0.78
19
3.03
13.1
256
119
42.3
0.59
16
2.91
12.6
243
113
50.1
0.56
16
3.10
13.4
268
128
46.3
0.54
16
3.03
13.1
260
124
51.6
0.59
15
3.13
13.5
270
130
46.4
0.41
12
3.00
13.0
257
123
53.8
0.36
11
3.20
13.8
279
137
49.7
0.35
11
3.12
13.5
271
133
55.4
0.38
11
3.23
14.0
282
138
-
43.9
0.86
22
3.17
13.7
264
117
40.6
0.83
22
3.09
13.3
256
113
45.3
0.90
21
3.20
13.8
267
118
39.9
0.73
19
3.07
13.2
254
112
45.2
0.77
20
3.24
14.0
285
124
41.8
0.74
20
3.16
13.6
276
120
46.6
0.80
19
3.27
14.1
287
125
41.3
0.61
16
3.13
13.5
273
119
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
40.8
0.70
19
2.85
12.3
226
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
52.6
0.37
11
3.45
14.9
313
144
48.5
0.36
11
3.37
14.5
304
140
54.1
0.39
11
3.48
15.0
317
146
-
42.9
0.88
22
3.37
14.7
301
121
39.6
0.85
22
3.29
14.4
292
118
44.2
0.92
21
3.40
14.8
304
122
38.9
0.75
19
3.26
14.2
289
116
44.2
0.79
20
3.44
15.0
324
129
40.8
0.76
20
3.36
14.7
314
125
45.5
0.82
19
3.47
15.2
327
130
40.4
0.62
16
3.33
14.5
311
124
47.8
0.59
16
3.56
15.5
342
141
44.1
0.57
17
3.47
15.1
331
137
49.2
0.62
16
3.59
15.6
345
142
44.2
0.43
13
3.44
15.0
328
135
51.3
0.38
11
3.68
16.0
356
150
47.4
0.37
11
3.58
15.6
346
146
52.8
0.40
11
3.71
16.2
360
152
-
41.9
0.91
22
3.55
15.6
343
127
38.6
0.87
22
3.46
15.2
332
124
43.1
0.95
21
3.58
15.8
346
129
38.0
0.77
19
3.43
15.1
329
122
NOTE: Shaded area is ACCA (TVA) conditions
49.0
0.58
16
3.34
14.4
300
136
45.2
0.56
17
3.26
14.0
291
131
50.4
0.61
16
3.37
14.5
303
137
45.3
0.42
13
3.23
13.9
289
130
46.6
0.61
16
3.75
16.5
389
148
43.0
0.59
17
3.65
16.1
378
144
48.0
0.64
16
3.78
16.6
393
149
44.4
0.85
19
3.66
16.1
372
137
43.1
0.81
20
3.63
16.0
369
136
39.8
0.78
20
3.54
15.6
358
131
43.1
0.45
13
3.62
15.9
374
142
39.4
0.64
17
3.51
15.5
354
130
50.1
0.40
11
3.87
17.0
406
158
46.2
0.38
12
3.77
16.6
394
153
51.6
0.41
11
3.90
17.2
410
159
-
39.8
0.94
22
3.70
16.6
385
134
36.7
0.91
22
3.61
16.1
374
129
41.0
0.99
21
3.73
16.7
389
135
36.1
0.80
19
3.57
16.0
370
128
40.9
0.84
20
3.78
16.9
415
142
37.8
0.81
20
3.69
16.5
402
138
42.2
0.88
19
3.81
17.1
419
143
37.4
0.67
16
3.65
16.4
398
136
44.3
0.64
16
3.91
17.4
438
155
40.9
0.61
17
3.81
17.0
425
150
45.6
0.67
16
3.94
17.6
442
157
41.0
0.46
12
3.78
16.9
420
149
47.6
0.41
11
4.04
18.1
457
165
43.9
0.40
11
3.94
17.6
443
160
49.0
0.43
11
4.07
18.2
461
167
-
36.8
0.95
20
3.83
17.5
426
138
34.0
0.92
20
3.73
17.0
413
134
37.9
1.00
19
3.86
17.6
430
139
33.4
0.81
18
3.70
16.9
409
133
37.9
0.85
18
3.91
17.9
458
147
35.0
0.82
19
3.81
17.4
444
143
39.1
0.89
18
3.95
18.0
463
148
34.6
0.67
15
3.78
17.2
440
141
63
38.7
0.73
14
3.91
17.9
458
147
37.5
0.70
15
3.88
17.7
454
145
41.0
0.64
15
4.05
18.4
484
160
37.9
0.62
15
3.94
17.9
469
156
42.3
0.67
15
4.08
18.6
489
162
38.0
0.47
12
3.91
17.8
465
154
67
42.4
0.51
11
4.04
18.4
484
160
41.1
0.48
11
4.01
18.2
479
159
115
44.0
0.41
10
4.18
19.1
505
171
40.7
0.40
11
4.08
18.6
489
166
45.4
0.43
10
4.22
19.2
510
173
-
71
-
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
45.6 47.2 51.7
44.5 46.1 50.5
43.4 45.0 49.3
42.4
43.9
48.1
40.3 41.7 45.7
37.3
S/T
0.76 0.64 0.44
0.79 0.66 0.46
0.81 0.68 0.47
0.84
0.70
0.48
0.87 0.73 0.50
0.88
Delta T
18
15
12
18
16
12
18
16
12
18
16
12
18
15
12
17
1800
KW
2.94 3.01 3.10
3.17 3.24 3.34
3.37 3.44 3.56
3.55
3.63
3.75
3.70 3.78 3.91
3.83
AMPS
12.7 13.0 13.4
13.7 14.0 14.4
14.7 15.0 15.5
15.6
16.0
16.5
16.6 16.9 17.4
17.5
HI PR
236
254
268
264
284
300
301
324
342
342
369
389
385
415
438
426
LO PR
110
117
128
117
124
135
121
129
141
127
135
148
133
142
155
138
MBh
44.2 45.9 50.2
43.2 44.8 49.1
42.2 43.7 47.9
41.2
42.7
46.7
39.1 40.5 44.4
36.2
S/T
0.73 0.61 0.42
0.75 0.63 0.44
0.77 0.65 0.45
0.80
0.67
0.46
0.83 0.69 0.48
0.84
Delta T
18
16
12
19
16
12
19
16
12
19
16
12
19
16
12
17
70
1600
KW
2.92 2.98 3.08
3.14 3.21 3.32
3.34 3.42 3.53
3.52
3.60
3.71
3.67 3.75 3.87
3.80
AMPS
12.6 12.9 13.3
13.6 13.8 14.3
14.6 14.9 15.4
15.5
15.9
16.3
16.4 16.8 17.3
17.3
HI PR
233
251
265
262
282
297
298
320
338
339
365
385
381
410
433
421
LO PR
109
116
127
116
123
134
120
128
139
126
134
146
132
141
153
137
MODEL: GPC1448H41A*
COOLING PERFORMANCE DATA
GPC1448H41A*
21
22
EXPANDED PERFORMANCE DATA
85
80
42.3
0.87
24
2.90
12.5
231
108
48.0
1.00
24
3.01
13.1
243
114
46.6
0.95
25
2.99
13.0
240
113
43.0
0.92
26
2.92
12.6
233
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1600
1400
1800
1600
1400
43.8
0.88
25
2.98
12.9
251
116
47.5
0.92
25
3.05
13.2
259
120
48.9
0.96
24
3.08
13.3
261
121
43.2
0.82
23
2.96
12.8
248
115
46.8
0.85
23
3.03
13.1
256
119
45.9
0.80
24
3.07
13.3
265
127
49.7
0.83
24
3.15
13.6
273
131
51.2
0.87
23
3.18
13.7
276
132
46.1
0.67
20
3.05
13.2
262
126
50.0
0.69
20
3.13
13.5
270
130
49.0
0.65
21
3.17
13.7
276
135
53.1
0.67
20
3.25
14.1
285
139
54.7
0.70
20
3.28
14.2
288
141
49.3
0.50
16
3.15
13.6
274
134
53.4
0.52
16
3.23
14.0
282
138
42.0
0.95
26
3.14
13.5
262
115
45.5
0.99
26
3.22
13.9
270
119
46.9
1.00
24
3.25
14.0
272
120
41.3
0.91
25
3.12
13.4
259
114
44.7
0.94
24
3.20
13.8
267
118
42.8
0.92
26
3.21
13.8
282
123
46.4
0.95
25
3.29
14.2
290
127
47.8
1.00
24
3.32
14.3
293
128
42.2
0.85
24
3.19
13.7
279
122
45.7
0.88
23
3.27
14.1
287
125
44.8
0.83
24
3.31
14.2
297
134
48.6
0.86
24
3.40
14.6
307
138
50.0
0.90
23
3.43
14.7
310
140
45.1
0.69
20
3.29
14.1
294
133
48.8
0.72
20
3.37
14.5
304
137
47.8
0.67
21
3.42
14.7
310
143
51.8
0.70
21
3.51
15.1
320
147
53.4
0.73
20
3.54
15.2
323
149
48.2
0.52
16
3.40
14.6
307
141
52.2
0.54
16
3.48
15.0
317
146
41.0
0.97
26
3.34
14.6
298
120
44.4
1.00
26
3.43
15.0
307
124
45.8
1.00
23
3.46
15.1
310
125
40.3
0.93
25
3.31
14.5
295
119
43.7
0.96
24
3.40
14.8
304
122
41.8
0.94
26
3.42
14.9
320
128
45.3
0.97
25
3.50
15.3
330
132
46.6
1.00
24
3.53
15.4
333
133
41.2
0.87
24
3.39
14.8
317
126
NOTE:
44.6
0.90
23
3.47
15.2
327
130
51.0
0.55
16
3.71
16.2
360
152
42.6
0.99
24
3.58
15.8
346
129
43.5
0.93
23
3.66
16.1
372
137
46.5
0.76
20
3.78
16.6
393
149
49.7
0.57
16
3.91
17.2
410
159
43.8
0.85
24
3.53
15.4
338
139
47.4
0.88
24
3.62
15.8
349
144
48.8
0.92
23
3.65
15.9
352
145
46.7
0.69
21
3.64
15.9
353
148
50.6
0.71
21
3.74
16.3
364
153
52.1
0.75
20
3.77
16.4
367
155
40.0
1.00
26
3.52
15.5
339
126
43.3
1.00
25
3.61
15.9
349
130
44.6
1.00
23
3.64
16.0
353
131
40.8
0.97
26
3.60
15.8
365
134
44.2
1.00
25
3.69
16.3
376
138
45.5
1.00
23
3.72
16.4
380
140
42.7
0.88
25
3.71
16.3
385
146
46.3
0.91
24
3.81
16.8
397
151
47.7
0.95
23
3.84
16.9
401
152
45.6
0.71
21
3.84
16.9
402
156
49.4
0.74
21
3.94
17.3
414
161
50.8
0.77
20
3.97
17.5
418
162
44.0 47.0 39.3
40.2
42.9
45.9
0.71 0.53 0.96
0.90
0.73
0.55
20
16
25
24
21
16
3.50 3.61 3.49
3.57
3.68
3.81
15.2 15.8 15.4
15.7
16.2
16.8
335
349
336
361
381
398
138
147
125
133
145
154
Shaded area reflects AHRI rating conditions
47.7
0.74
20
3.59
15.6
345
142
38.0
1.00
25
3.67
16.4
381
132
41.2
1.00
24
3.76
16.8
393
136
42.4
1.00
22
3.79
17.0
397
138
37.3
1.00
24
3.64
16.3
378
131
40.5
1.00
23
3.73
16.7
389
135
38.7
1.00
25
3.75
16.8
410
141
42.0
1.00
24
3.85
17.2
423
145
43.2
1.00
22
3.88
17.4
427
146
38.2
0.93
23
3.72
16.6
406
139
41.3
0.97
23
3.81
17.1
419
143
40.6
0.91
24
3.87
17.3
433
153
44.0
0.94
24
3.97
17.7
447
158
45.3
0.99
23
4.01
17.9
451
160
40.8
0.76
20
3.84
17.1
429
152
44.2
0.79
20
3.94
17.6
442
157
* NOTE: Shaded areas is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
45.8
0.91
24
2.97
12.9
238
112
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
43.3
0.74
21
4.00
17.9
452
163
46.9
0.76
21
4.11
18.4
466
168
48.3
0.80
20
4.14
18.5
471
170
43.6
0.57
16
3.97
17.7
447
162
47.2
0.59
16
4.07
18.2
461
167
35.2
1.00
23
3.79
17.3
421
137
38.1
1.00
22
3.89
17.8
434
141
39.3
1.00
20
3.93
17.9
439
142
34.6
1.00
23
3.76
17.2
417
135
37.5
1.00
22
3.86
17.6
430
139
35.9
1.00
24
3.88
17.7
453
145
38.9
1.00
22
3.98
18.2
467
150
40.0
1.00
20
4.02
18.3
472
151
35.4
0.94
22
3.85
17.5
449
144
38.3
0.98
21
3.95
18.0
463
148
63
39.5
1.00
20
3.98
18.2
467
150
37.6
0.92
23
4.01
18.2
479
159
40.7
0.95
22
4.11
18.7
494
164
41.9
1.00
21
4.15
18.9
499
165
37.8
0.77
19
3.98
18.1
474
157
40.9
0.79
19
4.08
18.6
489
162
67
42.1
0.83
18
4.11
18.7
494
164
115
40.1
0.74
20
4.15
18.9
499
169
43.4
0.77
19
4.26
19.4
515
174
44.7
0.81
18
4.29
19.6
520
176
40.4
0.57
15
4.11
18.7
494
167
43.7
0.59
15
4.22
19.2
510
173
71
45.1
0.62
14
4.26
19.4
515
174
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
47.2 48.2 51.5 55.0 46.1 47.1 50.3 53.8 45.0 46.0 49.1 52.5 43.9
44.8
47.9
51.2 41.7 42.6 45.5 48.6 38.6
S/T
0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00
1.00
0.80
0.60 1.00 1.00 0.83 0.62 1.00
Delta T
23
22
19
15
24
22
19
15
23
22
19
15
22
23
19
16
21
22
19
15
20
1800
KW
2.99 3.05 3.15 3.25 3.22 3.29 3.40 3.51 3.43 3.50 3.62 3.74 3.61
3.69
3.81
3.94 3.76 3.85 3.97 4.11 3.89
AMPS
13.0 13.2 13.6 14.1 13.9 14.2 14.6 15.1 15.0 15.3 15.8 16.3 15.9
16.3
16.8
17.3 16.8 17.2 17.7 18.4 17.8
HI PR
240
259
273
285
270
290
307
320
307
330
349
364
349
376
397
414
393
423
447
466
434
LO PR
113
120
131
139
119
127
138
147
124
132
144
153
130
138
151
161
136
145
158
168
141
MODEL: GPC1448H41A*
COOLING PERFORMANCE DATA
GPC1448H41A*
EXPANDED PERFORMANCE DATA
55.6
0.77
25
3.70
15.7
238
108
51.3
0.75
25
3.61
15.3
231
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1800
1400
1600
57.3
0.81
24
3.73
15.8
241
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
57.3
0.69
23
3.79
16.0
256
115
52.9
0.67
23
3.69
15.6
249
111
59.0
0.73
22
3.82
16.2
259
116
52.3
0.55
19
3.66
15.5
246
110
62.0
0.52
19
3.91
16.5
271
125
57.2
0.51
19
3.81
16.1
263
121
63.9
0.55
18
3.94
16.7
273
126
57.3
0.38
14
3.78
16.0
260
120
66.5
0.34
13
4.04
17.1
282
133
61.4
0.33
13
3.94
16.7
274
129
68.5
0.35
12
4.07
17.2
285
135
-
54.3
0.80
25
4.00
16.9
267
114
50.2
0.77
25
3.90
16.4
259
110
56.0
0.84
24
4.03
17.0
270
115
49.3
0.68
22
3.87
16.3
257
109
55.9
0.72
23
4.09
17.3
288
121
51.6
0.69
23
3.99
16.8
279
118
57.6
0.75
22
4.12
17.4
291
122
51.1
0.57
19
3.95
16.7
276
116
* IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
50.5
0.66
22
3.58
15.2
229
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
65.0
0.35
13
4.37
18.4
317
141
60.0
0.34
13
4.26
17.9
307
137
66.9
0.37
13
4.41
18.6
320
142
-
53.0
0.82
25
4.26
18.2
304
118
49.0
0.79
26
4.15
17.8
295
115
54.6
0.86
24
4.30
18.4
307
120
48.1
0.70
22
4.12
17.6
292
114
54.6
0.74
23
4.36
18.6
327
126
50.4
0.71
24
4.25
18.2
317
122
56.3
0.77
22
4.40
18.8
330
127
49.9
0.58
19
4.21
18.0
314
121
59.1
0.56
19
4.51
19.2
346
137
54.6
0.54
19
4.39
18.7
335
133
60.9
0.58
18
4.55
19.4
349
139
54.7
0.40
15
4.35
18.6
332
132
63.4
0.36
13
4.66
19.9
360
146
58.6
0.35
13
4.54
19.4
350
142
65.3
0.38
13
4.70
20.1
364
148
-
51.8
0.85
25
4.49
19.4
346
124
47.8
0.82
26
4.38
18.9
336
121
53.3
0.89
24
4.53
19.6
350
126
47.0
0.72
22
4.34
18.7
333
119
NOTE: Shaded area is ACCA (TVA) conditions
60.6
0.54
19
4.23
17.8
304
132
55.9
0.52
19
4.12
17.3
295
128
62.4
0.57
18
4.26
17.9
307
134
56.0
0.39
14
4.08
17.2
292
127
57.7
0.58
19
4.75
20.5
394
144
53.2
0.55
19
4.63
19.9
382
140
59.4
0.60
18
4.79
20.7
397
146
54.9
0.80
22
4.64
20.0
376
134
53.3
0.76
23
4.60
19.9
373
132
49.2
0.73
24
4.48
19.3
361
128
53.3
0.42
15
4.59
19.8
378
139
48.7
0.60
19
4.44
19.2
358
127
61.9
0.37
13
4.92
21.2
410
154
57.1
0.36
13
4.79
20.7
398
149
63.8
0.39
13
4.96
21.4
415
155
-
49.2
0.88
25
4.69
20.6
390
130
45.4
0.85
25
4.57
20.0
378
126
50.6
0.92
24
4.73
20.8
393
132
44.6
0.75
22
4.53
19.9
374
125
50.6
0.79
23
4.80
21.1
419
139
46.7
0.76
23
4.67
20.5
407
134
52.1
0.83
22
4.84
21.3
423
140
46.2
0.62
19
4.63
20.3
403
133
54.8
0.60
19
4.96
21.7
443
151
50.6
0.58
19
4.83
21.2
429
147
56.4
0.63
18
5.01
21.9
447
153
50.7
0.43
14
4.79
21.0
425
145
58.8
0.38
13
5.14
22.5
462
161
54.3
0.37
13
5.00
21.9
448
156
60.6
0.40
12
5.18
22.7
466
163
-
45.5
0.89
23
4.86
21.7
430
135
42.0
0.86
24
4.73
21.2
418
131
46.9
0.93
22
4.90
21.9
435
136
41.3
0.75
20
4.69
21.0
413
129
46.9
0.80
21
4.97
22.3
463
143
43.3
0.77
22
4.84
21.7
449
139
48.3
0.83
21
5.02
22.5
468
145
42.8
0.63
18
4.80
21.5
445
138
63
47.8
0.69
17
4.97
22.3
463
143
46.4
0.65
17
4.93
22.1
459
142
50.8
0.60
18
5.14
23.0
489
157
46.8
0.58
18
5.01
22.4
474
152
52.3
0.63
17
5.19
23.2
494
158
46.9
0.44
13
4.97
22.2
470
150
67
52.4
0.47
13
5.14
23.0
489
156
50.9
0.45
13
5.10
22.8
484
155
115
54.5
0.39
12
5.32
23.8
510
167
50.3
0.37
12
5.18
23.2
495
162
56.1
0.41
12
5.37
24.0
515
168
-
71
-
COOLING OPERATION
Design Subcooling, 6 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
56.3 58.4 64.0
55.0 57.0 62.5
53.7 55.7 61.0
52.4
54.3
59.5
49.8 51.6 56.5
46.1
S/T
0.71 0.60 0.41
0.74 0.62 0.43
0.76 0.63 0.44
0.78
0.65
0.45
0.81 0.68 0.47
0.82
Delta T
21
18
14
21
18
14
21
18
14
21
18
14
21
18
14
19
1800
KW
3.70 3.78 3.91
4.00 4.09 4.23
4.26 4.36 4.51
4.49
4.60
4.75
4.69 4.80 4.96
4.86
AMPS
15.7 16.0 16.5
16.9 17.2 17.8
18.2 18.6 19.2
19.4
19.9
20.5
20.6 21.1 21.7
21.7
HI PR
238
256
271
267
288
304
304
327
345
346
373
393
390
419
443
430
LO PR
108
115
125
114
121
132
118
126
137
124
132
144
130
139
151
135
MBh
54.7 56.7 62.1
53.4 55.4 60.7
52.2 54.1 59.2
50.9
52.7
57.8
48.3 50.1 54.9
44.8
S/T
0.68 0.57 0.39
0.71 0.59 0.41
0.72 0.60 0.42
0.75
0.62
0.43
0.78 0.65 0.45
0.78
Delta T
21
19
14
22
19
14
22
19
14
22
19
14
22
19
14
20
70
1600
KW
3.67 3.75 3.88
3.97 4.06 4.19
4.23 4.32 4.47
4.46
4.56
4.71
4.65 4.76 4.92
4.82
AMPS
15.6 15.9 16.4
16.7 17.1 17.6
18.1 18.5 19.1
19.2
19.7
20.3
20.4 20.9 21.5
21.6
HI PR
236
254
268
265
285
301
301
324
342
343
369
390
386
415
438
426
LO PR
107
114
124
113
120
131
117
125
136
123
131
143
129
137
150
133
MODEL: GPC1460H41A*
COOLING PERFORMANCE DATA
GPC1460H41A*
23
24
EXPANDED PERFORMANCE DATA
85
80
52.3
0.82
28
3.64
15.4
233
106
59.3
0.93
28
3.80
16.1
245
111
57.6
0.89
29
3.77
16.0
243
110
53.2
0.86
30
3.67
15.6
236
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1600
1400
1800
1600
1400
54.2
0.83
30
3.75
15.9
254
113
58.7
0.86
29
3.85
16.3
262
117
60.5
0.90
28
3.88
16.5
264
118
53.4
0.77
27
3.72
15.8
251
112
57.9
0.80
26
3.82
16.2
259
116
56.8
0.75
28
3.88
16.4
268
124
61.5
0.78
27
3.98
16.8
276
128
63.3
0.81
26
4.01
17.0
279
129
57.1
0.63
23
3.84
16.2
265
123
61.8
0.65
23
3.94
16.7
273
126
60.6
0.61
24
4.01
17.0
279
132
65.6
0.63
24
4.11
17.4
288
136
67.6
0.66
23
4.14
17.5
291
137
61.0
0.47
19
3.97
16.8
277
131
66.1
0.48
18
4.08
17.2
285
135
51.9
0.89
30
3.97
16.7
265
113
56.3
0.92
30
4.07
17.2
273
116
58.0
0.97
29
4.10
17.3
275
117
51.0
0.85
28
3.93
16.6
262
112
55.3
0.88
28
4.03
17.0
270
115
52.9
0.86
30
4.05
17.1
285
120
57.4
0.89
29
4.16
17.5
294
124
59.1
0.93
28
4.20
17.7
296
125
52.2
0.80
27
4.02
17.0
282
119
56.5
0.83
27
4.13
17.4
291
122
55.4
0.78
28
4.19
17.6
301
131
60.1
0.80
28
4.30
18.1
310
135
61.9
0.84
27
4.34
18.2
313
136
55.7
0.65
24
4.15
17.5
298
130
60.4
0.67
23
4.26
17.9
307
134
59.2
0.63
24
4.33
18.2
314
139
64.1
0.65
24
4.45
18.7
323
144
66.0
0.68
23
4.48
18.9
326
145
59.6
0.48
19
4.29
18.1
310
138
64.5
0.50
19
4.41
18.6
320
142
50.7
0.91
30
4.23
18.1
301
117
54.9
0.95
30
4.34
18.5
310
121
56.6
0.99
29
4.37
18.7
313
122
49.8
0.87
28
4.19
17.9
298
116
54.0
0.90
28
4.30
18.4
307
120
51.7
0.88
30
4.32
18.5
324
125
56.0
0.91
29
4.43
19.0
334
128
57.7
0.96
28
4.47
19.1
337
130
50.9
0.82
27
4.28
18.3
321
123
NOTE:
55.2
0.85
27
4.40
18.8
331
127
63.0
0.52
19
4.70
20.1
364
148
52.7
0.93
28
4.53
19.6
350
126
53.8
0.87
27
4.64
20.0
376
134
57.5
0.71
24
4.80
20.7
398
146
61.5
0.53
19
4.96
21.4
415
155
54.1
0.79
28
4.47
19.1
342
136
58.6
0.82
28
4.58
19.6
352
140
60.4
0.86
27
4.62
19.7
356
142
57.7
0.64
24
4.62
19.7
357
145
62.6
0.67
24
4.74
20.3
368
149
64.4
0.70
23
4.78
20.4
371
151
49.5
0.94
31
4.45
19.2
343
123
53.6
0.98
30
4.57
19.8
353
127
55.2
1.00
28
4.61
19.9
357
128
50.4
0.91
30
4.56
19.7
369
131
54.6
0.94
30
4.68
20.2
380
135
56.3
0.99
28
4.72
20.4
384
136
52.8
0.82
28
4.71
20.3
389
143
57.2
0.85
28
4.84
20.8
401
147
58.9
0.89
27
4.88
21.0
405
149
56.3
0.67
25
4.87
21.0
406
152
61.0
0.69
24
5.00
21.6
419
157
62.9
0.72
23
5.05
21.8
423
158
54.4 58.2 48.6
49.7
53.1
56.7
0.66 0.50 0.90
0.84
0.69
0.51
24
19
29
27
24
19
4.43 4.58 4.42
4.52
4.67
4.83
18.9 19.6 19.1
19.5
20.1
20.8
339
353
339
365
386
402
135
143
122
130
141
151
Shaded area reflects AHRI rating conditions
58.9
0.69
23
4.55
19.4
349
139
47.0
0.98
30
4.65
20.4
386
129
50.9
1.00
29
4.77
21.0
397
133
52.4
1.00
27
4.81
21.1
401
134
46.2
0.93
28
4.61
20.2
382
128
50.0
0.97
28
4.73
20.8
394
132
47.9
0.94
30
4.76
20.9
415
137
51.9
0.98
29
4.88
21.4
428
141
53.5
1.00
27
4.93
21.6
432
143
47.2
0.87
27
4.71
20.7
411
136
51.1
0.91
27
4.84
21.3
423
140
50.2
0.85
28
4.92
21.5
438
150
54.4
0.88
28
5.05
22.1
452
154
56.0
0.93
26
5.09
22.3
456
156
50.4
0.71
24
4.88
21.3
434
148
54.6
0.74
23
5.01
21.9
447
153
* NOTE: Shaded areas is AHRI Rating Conditions
IDB: Entering Indoor Dry Bulb Temperature
KW = Total system power
High and low pressures are measured at the liquid and suction access fittings.
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
56.6
0.85
28
3.73
15.8
241
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
53.5
0.69
24
5.09
22.3
457
159
58.0
0.72
24
5.23
22.9
471
164
59.7
0.75
23
5.27
23.1
476
166
53.9
0.53
19
5.05
22.1
452
158
58.4
0.55
19
5.18
22.7
466
163
43.5
0.99
28
4.82
21.5
426
133
47.2
1.00
27
4.95
22.1
439
137
48.6
1.00
25
4.99
22.3
444
139
42.8
0.94
26
4.78
21.4
422
132
46.3
0.98
26
4.90
21.9
435
136
44.4
0.95
28
4.93
22.1
458
142
48.1
0.99
27
5.06
22.7
473
146
49.5
1.00
25
5.10
22.9
477
148
43.7
0.88
25
4.89
21.9
454
140
47.4
0.91
25
5.02
22.5
468
145
63
48.8
0.96
24
5.06
22.7
473
146
46.5
0.86
26
5.10
22.8
484
155
50.3
0.89
26
5.24
23.4
499
160
51.9
0.93
25
5.28
23.6
504
161
46.7
0.72
22
5.05
22.6
479
153
50.6
0.74
22
5.19
23.2
494
158
67
52.1
0.78
21
5.24
23.4
499
160
115
49.6
0.70
23
5.28
23.6
505
165
53.7
0.72
22
5.42
24.2
520
170
55.3
0.76
21
5.47
24.5
526
172
49.9
0.54
18
5.23
23.4
500
163
54.1
0.56
17
5.37
24.0
515
168
71
55.7
0.58
17
5.42
24.2
520
170
COOLING OPERATION
Design Subcooling, 6 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
58.3 59.6 63.7 68.1 57.0 58.2 62.2 66.5 55.6 56.8 60.7 64.9 54.3
55.4
59.2
63.3 51.5 52.7 56.3 60.1 47.7
S/T
0.89 0.84 0.68 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.72 0.54 1.00
0.92
0.75
0.56 1.00 0.95 0.77 0.58 1.00
Delta T
27
25
22
18
27
26
22
18
27
26
22
18
28
26
23
18
26
26
22
18
24
1800
KW
3.77 3.85 3.98 4.11 4.07 4.16 4.30 4.45 4.34 4.43 4.58 4.74 4.57
4.68
4.84
5.00 4.77 4.88 5.05 5.23 4.95
AMPS
16.0 16.3 16.8 17.4 17.2 17.5 18.1 18.7 18.5 19.0 19.6 20.3 19.8
20.2
20.8
21.6 21.0 21.4 22.1 22.9 22.1
HI PR
243
262
276
288
273
294
310
323
310
334
352
368
353
380
401
419
397
428
452
471
439
LO PR
110
117
128
136
116
124
135
144
121
128
140
149
127
135
147
157
133
141
154
164
137
MODEL: GPC1460H41A*
COOLING PERFORMANCE DATA
GPC1460H41A*
COOLING PERFORMANCE DATA
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
25
WIRING DIAGRAMS
GPC14[24-60]H41A*
PU
NOTE #3
BK
BK
1
C
2
PU
PU
3
BL
208 240
BK
BL
24V
RD
C
WARNING
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
BL
BK
BK
2
0
8
2
4
0
/
1
/
L2
T2
RD
SEE NOTE 5
L1
T1
RD
YL
GND
GR
BK
60
RD
RD
YL
PU
LVJB
YL
RD BR
WH
BL
YL
H
BL
C F
RCCF
GR
WH
GR
PLF
3
6
9
2
5
8
1
4
7
BR
PU
YL
RD
GR
WH
Y
R
G
W1
BR
BL
W2
C
++
BR
RD
BK
SA
(IF USED) SEE NOTE 4
CONTROL
BOX
RD
BK
YL
T
H
E
R
M
O
S
T
A
T
PU BR BK
WH GR
YL
S C R
C L G N
1 2 3 4 5
CM
COMP
HPS
WH
SEE NOTE 2
EM
L1
L2
SUPPLY VOLTAGE
208-240/1/60
T2
C
C
R
T1
C COMP
C
S
H
COMPONENT LEGEND
C
CM
COMP
EM
GND
LVJB
PLF
RCCF
RCCF
F
S.A.
SA
TR
HPS
CM
NOTE #4
IF USED
NOTE #2
L
N
EM
1
G
3
2
208-240
NOTE #4
3
2
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
HIGH PRESSURE SWITCH
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW
1
TR
24V
NOTES:
1 EM C
2
3
SEE NOTE #2
4
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY.
++ USE N.E.C. CLASS 2 WIRE
5
6
PLF
C
HPS
R
W2
W1
Y
G
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
C
THERMOSTAT
208-240/1/60 0140G00871 REV. B
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
26