Download Cooper Lighting Metalux MB254 User's Manual
Transcript
COOPER LIGHTING - METALUX DESCRIPTION The MB series is a functional and multi-purpose narrow profile fluorescent High-Bay that incorporates premium performance with durable construction. Designed for T5 fluorescent technology, the MB series offers both high performance and application versatility with three optical configurations for general and aisle applications. ® Type Catalog # Project Date Comments Illumination solution in commercial, industrial and retail applications, MB series can be used in warehouses and retail store distribution centers. Prepared by SPECIFICATION FEATURES A ... Construction Die formed channel from 20 gauge prime cold rolled steel. Numerous KOs for ease of installation. End plate quickly converts to snap-in channel connector for continuous row alignment. Push-in style lampholders snap in to installed tracks. Channel/wireway cover positively secured with mechanical fastener. D ... Channel/Wireway Cover Heavy gauge prime cold rolled steel. Tight fit for ease of maintenance. F ... Mounting Suspension is convenient and flexible with the SS Aircraft Cable "Y" Toggle Mounting Kits. Adjustment for luminaire mounting height is provided at luminaire rather than structure. Order a rigid exterior connector/coupling with pre-punched holes to facilitate easy installation of coupled sections up to 32' long. E ... Reflector Specular Miro reflectors for precise light control minimum 95% total reflectivity. Three optical distribution patterns are available: Focus - SC less than .9 Task - .9 less than or equal to SC less than 1.2 Normal - 1.2 less than or equal to SC less than or equal to 1.4 B ... Electrical* Ballasts are Class "P" and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations. Option Integral occupancy sensor available and provides from 600 sq. ft. up to 1250 sq. ft. of coverage in a maximum mounting height of 40'. MB 154 254 C ... Finish Multistage iron phosphate pretreatment ensures maximum bonding and rust inhibitor. A B C D 4' OR 8' MICROBAY* 1 OR 2 LAMP T5 Lamp Technology Task Beam Focus Beam Normal Beam *Patent Pending E 3-9/32" [84mm] Focus Beam 4-5/16" [110mm] LAMP CONFIGURATIONS Focus Beam 1 or 2 Lamp T5 Task Beam 1 Lamp T5 Task Beam 2 Lamp T5 Normal Beam 1 or 2 Lamp T5 X X X X 1-31/32" [51mm] 3-9/32" [84mm] X=2-11/16" [69mm] 1" [26mm] 4-5/16" [110mm] 1-3/16" [30mm] 5-7/8" [150mm] X=2-11/16" [69mm] X=2-11/16" [69mm] 7-7/32" [184mm] 1-31/32" [51mm] 3-9/32" [84mm] 1-3/16" [31mm] 4-5/16" [110mm] X=2-11/16" [69mm] MOUNTING DATA Input Watts @ 120V: 1-31/32" [51mm] 3-9/32" [84mm] 1-7/16" [37mm] 4-5/16" [110mm] ISOMETRIC VIEW 7/8" [23mm] K.O. (3) Ceiling Stand-Off Embossments E N E R G Y D ATA Electronic Ballast & STD Lamps 154 (62) 254 (117) 454 (229) 8T154 (117) 8T254 (229) Luminaire Efficacy Rating LER = 69 Catalog Number: MB-154T5 1-3/4" x 3-1/4" K.O. (1) Ground Screw Bump Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.47 2-11/16" [69mm] 43-3/4" [1112mm] Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 48" [1220mm] 7/8" [22mm] K.O. (3) 1-3/4" x 3-1/4" K.O. (1) Ceiling Stand-Off Embossments Ground Screw Bump 2-11/16" [68mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 91-3/4" [2330mm] 96" [2438mm] Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. Safe and convenient means of disconnecting power ADF060486 10/06/2008 10:47:32 AM MB PHOTOMETRICS MB-254-TB-UNV-EBT1 (1) Electronic Ballast (2) 54W T5 lamp 4400 lumens Spacing criterion: (II) 1.2 x mounting height, ( ) 0.9 x mounting height Efficiency 95.3% Test Report: 10579 LER =69 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.47 || C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 113 104 95 87 79 72 67 62 57 52 49 113 99 87 77 68 60 54 49 44 39 36 113 95 80 69 60 52 45 40 35 31 28 113 92 75 63 53 45 39 34 30 26 23 111 101 92 84 77 70 65 60 55 51 47 111 97 85 75 67 59 53 48 43 39 35 111 93 79 68 59 51 45 40 35 31 28 111 90 74 62 53 45 39 34 30 26 23 Candela 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 3550 3526 3479 3399 3285 3142 2968 2767 2539 2296 2030 1749 1459 1150 852 553 285 85 5 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 106 106 93 90 82 77 72 66 64 58 57 50 51 44 46 39 42 35 38 30 34 27 101 89 78 70 62 55 50 45 40 36 33 97 86 76 67 60 53 48 44 39 35 32 95 80 67 57 49 41 36 31 27 23 21 106 87 72 61 52 44 39 34 29 26 23 101 87 74 65 56 49 43 38 34 30 27 101 85 71 60 52 44 38 33 29 25 23 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp %Fixture 2285 3626 6319 8379 8388 26.0 41.2 71.8 95.2 95.3 27.2 43.2 75.3 99.9 100.0 3550 3199 2863 2716 2518 2267 2098 1995 1855 1813 1689 1524 1432 1317 1060 773 498 2450 69 || Efficiency 105% Test Report: 227P132 LER =-74 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.24 C o e f fi c i e n t s o f U t i l i z a t i o n 20% Zonal Lumen Summary Lumens 3550 3363 2995 2787 2637 2460 2202 1995 1830 1677 1505 1414 1251 1081 974 741 468 223 50 Average 0-Deg cd/sm 188780 169445 140863 96146 26928 Average 45-Deg cd/sm 32821 33582 33957 35988 25590 97 84 72 63 55 48 42 38 33 30 27 97 82 69 59 51 43 38 33 29 25 22 Average 90-Deg cd/sm 35803 36677 42208 38836 30619 MB-154-FB-UNVEB51-U (1) Electronic Ballast (1) 54W T5 lamp 4400 lumens Spacing criterion: (II) 1.2 x mounting height, ( ) 0.5 x mounting height rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 125 115 105 97 89 83 77 73 68 64 61 125 110 97 86 77 70 64 59 55 51 48 125 125 105 101 90 84 78 71 69 62 61 55 56 49 51 45 46 41 43 37 40 35 122 112 102 94 87 81 76 71 67 63 59 122 107 95 84 76 69 63 58 54 50 47 122 103 88 77 68 61 55 50 46 43 40 Candela 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 3538 3528 3477 3393 3275 3126 2944 2734 2498 2239 1961 1663 1357 1043 729 438 197 39 0 50% 50 30 10 30% 50 30 10 50 117 103 91 81 73 67 62 57 53 49 46 112 99 88 78 71 65 60 55 52 48 45 107 95 84 76 69 63 58 54 50 47 44 117 99 86 75 66 60 54 49 46 42 39 117 96 81 70 61 54 49 44 40 37 35 112 96 83 73 65 59 53 49 45 42 39 112 93 79 68 60 53 48 44 40 37 34 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp %Fixture 1775 2479 3657 4632 4632 40.4 56.3 83.1 105.3 105.3 38.3 53.5 79.0 100.0 100.0 3538 3281 2542 1786 1322 915 714 613 564 543 537 534 534 534 535 473 312 135 0 20% 122 100 83 71 62 55 49 44 41 37 35 Lumens 3538 3409 2970 2349 1777 1376 1020 752 596 504 449 416 396 378 364 353 289 131 0 Average 0-Deg cd/sm 22714 20798 17703 12139 3210 Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 Average 45-Deg cd/sm 5113 5203 6416 9784 10782 10% 30 10 107 93 81 71 64 57 52 48 44 41 38 107 91 77 67 59 53 48 43 40 37 34 0% 0 105 88 75 65 57 51 46 42 38 35 33 Average 90-Deg cd/sm 5509 6678 9064 13110 11111 ADF060486 10/06/2008 10:47:32 AM ORDERING INFORMATION S A M P L E N U M B E R : M B - 1 3 2 - N B - U N V- E B 8 1- U Tandem Blank= 4' Length 8T= 8' Length Ballast Type (1) T5 Systems EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10%(5) No. of Ballast 1 or 2 EHT =T5 Linear Electronic Program Rapid Start High Ambient. Total Harmonic Distortion < 10%(6) No. of Ballast 1 or 2 DIM=Consult Factory(6) Series MB= Micro-Bay Number of Lamps (Not included) 1=1 Lamp 2=2 Lamps Lamp Types 54T5=54W T5HO (4') Lamp Reflector FB=Focus Beam TB=Task Beam (Medium) NB=Normal Beam Voltage UNV=Universal 120-277 Voltage UNC=Universal 347/480 Voltage(4) Options PI/CPI=Plug-In (1, 2 or 3) (see ordering information below) C3=3' Power Cord C6=6' Power Cord PC3-=3' Power Cord & Plug (Specify Voltage) (3) PC6-=6' Power Cord & Plug (Specify Voltage) (3) Packaging U=Unit Pack Accessories (order separately) GRIPPLE-Y- =Y Mounting Toggle, #2 Cable (Specify 10' or 30') (Row Mount) GRIPPLE-TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30') (Stand Alone) MB-EXT-LONG-CONN-KIT-U=Rigid Connector Support for Continuous Channel Installation MS=Aisle Coverage Motion Sensor (3) (6) MSO=360° Coverage Motion Sensor (3) (6) MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage Motion Sensor, Center Mount Hardware, 120/277V MB-SENSOR-KIT-END/MT-U=Aisle Coverage Motion Sensor, End Mount Hardware, 120/277V MB-SENSOR-KIT-END/480V-U=Aisle Coverage Motion Sensor, End Mount Hardware, 480V Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (2) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Voltage to be specified with emergency ballast option.(3) Voltage must be specified when ordered with plugs, motion or emergency ballasts. (4) 2 lamp ballast configurations only in UNC versions. (6) Dimming ballast must be specified at time of order. PI OPTION ORDER INFORMATION Catalog Number Suffix PI 1 BLK PI 2 BLU PI 2 BLK Number of Circuits 1 2 2 Circuit Wired To Ballast Black Blue Black PI 3 RED PI 3 BLU PI 3 BLK 3 3 3 Red Blue Black Catalog Numbering System The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows: PI-1 = One Circuit - 2 Wires: one black, one white PI-2 = Two Circuits - 3 Wires: one black, one blue, one white PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered separately if PI option is chosen. PI1 - Single Circuit Plug-In P I 2 - Tw o C i r c u i t P l u g - I n SAMPLE NUMBER: PI1BLK-WG SAMPLE NUMBER: PI2BLK-WG PI1= Single Circuit BLK=Black Hot NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) SAMPLE NUMBER: PI3BLK-WG BLK=Black Hot BLU=Blue Hot RED=Red Hot Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral BLK=Black Hot BLU=Blue Hot Leave Blank=Single Neutral 2NEU=Two Neutrals Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral PI3 - Three Circuit Plug-In PI3= Three Circuit PI2= Two Circuit Leave Blank=Single Neutral 2NEU=Two Neutrals NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) SHIPPING INFORMATION For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Catalog No. Wt. MB-154T5 6 lbs. Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADF060486 10/06/2008 10:47:32 AM