Download Cooper Lighting Metalux MB254 User's Manual

Transcript
COOPER LIGHTING - METALUX
DESCRIPTION
The MB series is a functional and multi-purpose narrow profile fluorescent
High-Bay that incorporates premium performance with durable
construction. Designed for T5 fluorescent technology, the MB series offers
both high performance and application versatility with three optical
configurations for general and aisle applications.
®
Type
Catalog #
Project
Date
Comments
Illumination solution in commercial, industrial and retail applications, MB
series can be used in warehouses and retail store distribution centers.
Prepared by
SPECIFICATION FEATURES
A ... Construction
Die formed channel from 20 gauge
prime cold rolled steel. Numerous
KOs for ease of installation. End
plate quickly converts to snap-in
channel connector for continuous
row alignment. Push-in style
lampholders snap in to installed
tracks. Channel/wireway cover
positively secured with mechanical
fastener.
D ... Channel/Wireway Cover
Heavy gauge prime cold rolled
steel. Tight fit for ease of
maintenance.
F ... Mounting
Suspension is convenient and
flexible with the SS Aircraft Cable
"Y" Toggle Mounting Kits. Adjustment for luminaire mounting
height is provided at luminaire
rather than structure. Order a rigid
exterior connector/coupling with
pre-punched holes to facilitate
easy installation of coupled
sections up to 32' long.
E ... Reflector
Specular Miro reflectors for precise
light control minimum 95% total
reflectivity. Three optical
distribution patterns are available:
Focus - SC less than .9
Task - .9 less than or equal to SC
less than 1.2
Normal - 1.2 less than or equal to
SC less than or equal to 1.4
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
Option
Integral occupancy sensor available and provides from 600 sq. ft.
up to 1250 sq. ft. of coverage in a
maximum mounting height of 40'.
MB
154
254
C ... Finish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor.
A
B
C D
4' OR 8' MICROBAY*
1 OR 2 LAMP
T5 Lamp Technology
Task Beam
Focus Beam
Normal Beam
*Patent Pending
E
3-9/32"
[84mm]
Focus Beam
4-5/16"
[110mm]
LAMP CONFIGURATIONS
Focus Beam 1 or 2 Lamp T5
Task Beam 1 Lamp T5
Task Beam 2 Lamp T5
Normal Beam 1 or 2 Lamp T5
X
X
X
X
1-31/32" [51mm]
3-9/32"
[84mm]
X=2-11/16"
[69mm]
1"
[26mm]
4-5/16"
[110mm]
1-3/16"
[30mm]
5-7/8"
[150mm]
X=2-11/16"
[69mm]
X=2-11/16"
[69mm]
7-7/32" [184mm]
1-31/32" [51mm]
3-9/32"
[84mm]
1-3/16"
[31mm]
4-5/16"
[110mm]
X=2-11/16"
[69mm]
MOUNTING DATA
Input Watts @ 120V:
1-31/32" [51mm]
3-9/32"
[84mm]
1-7/16"
[37mm]
4-5/16"
[110mm]
ISOMETRIC VIEW
7/8" [23mm] K.O. (3)
Ceiling Stand-Off
Embossments
E N E R G Y D ATA
Electronic Ballast & STD Lamps
154 (62)
254 (117)
454 (229)
8T154 (117)
8T254 (229)
Luminaire Efficacy Rating
LER = 69
Catalog Number: MB-154T5
1-3/4" x 3-1/4" K.O. (1)
Ground Screw Bump
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.47
2-11/16"
[69mm]
43-3/4" [1112mm]
Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
48" [1220mm]
7/8" [22mm] K.O. (3)
1-3/4" x 3-1/4" K.O. (1)
Ceiling Stand-Off Embossments
Ground Screw Bump
2-11/16"
[68mm]
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
91-3/4" [2330mm]
96" [2438mm]
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
Safe and convenient means of
disconnecting power
ADF060486
10/06/2008 10:47:32 AM
MB
PHOTOMETRICS
MB-254-TB-UNV-EBT1
(1) Electronic Ballast
(2) 54W T5 lamp
4400 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 0.9 x
mounting height
Efficiency 95.3%
Test Report:
10579
LER =69
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.47
||
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
113
104
95
87
79
72
67
62
57
52
49
113
99
87
77
68
60
54
49
44
39
36
113
95
80
69
60
52
45
40
35
31
28
113
92
75
63
53
45
39
34
30
26
23
111
101
92
84
77
70
65
60
55
51
47
111
97
85
75
67
59
53
48
43
39
35
111
93
79
68
59
51
45
40
35
31
28
111
90
74
62
53
45
39
34
30
26
23
Candela
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3550
3526
3479
3399
3285
3142
2968
2767
2539
2296
2030
1749
1459
1150
852
553
285
85
5
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
106 106
93 90
82 77
72 66
64 58
57 50
51 44
46 39
42 35
38 30
34 27
101
89
78
70
62
55
50
45
40
36
33
97
86
76
67
60
53
48
44
39
35
32
95
80
67
57
49
41
36
31
27
23
21
106
87
72
61
52
44
39
34
29
26
23
101
87
74
65
56
49
43
38
34
30
27
101
85
71
60
52
44
38
33
29
25
23
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
%Fixture
2285
3626
6319
8379
8388
26.0
41.2
71.8
95.2
95.3
27.2
43.2
75.3
99.9
100.0
3550
3199
2863
2716
2518
2267
2098
1995
1855
1813
1689
1524
1432
1317
1060
773
498
2450
69
||
Efficiency 105%
Test Report:
227P132
LER =-74
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.24
C o e f fi c i e n t s o f U t i l i z a t i o n
20%
Zonal Lumen Summary
Lumens
3550
3363
2995
2787
2637
2460
2202
1995
1830
1677
1505
1414
1251
1081
974
741
468
223
50
Average
0-Deg
cd/sm
188780
169445
140863
96146
26928
Average
45-Deg
cd/sm
32821
33582
33957
35988
25590
97
84
72
63
55
48
42
38
33
30
27
97
82
69
59
51
43
38
33
29
25
22
Average
90-Deg
cd/sm
35803
36677
42208
38836
30619
MB-154-FB-UNVEB51-U
(1) Electronic Ballast
(1) 54W T5 lamp
4400 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 0.5 x
mounting height
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
125
115
105
97
89
83
77
73
68
64
61
125
110
97
86
77
70
64
59
55
51
48
125 125
105 101
90 84
78 71
69 62
61 55
56 49
51 45
46 41
43 37
40 35
122
112
102
94
87
81
76
71
67
63
59
122
107
95
84
76
69
63
58
54
50
47
122
103
88
77
68
61
55
50
46
43
40
Candela
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3538
3528
3477
3393
3275
3126
2944
2734
2498
2239
1961
1663
1357
1043
729
438
197
39
0
50%
50 30 10
30%
50 30 10
50
117
103
91
81
73
67
62
57
53
49
46
112
99
88
78
71
65
60
55
52
48
45
107
95
84
76
69
63
58
54
50
47
44
117
99
86
75
66
60
54
49
46
42
39
117
96
81
70
61
54
49
44
40
37
35
112
96
83
73
65
59
53
49
45
42
39
112
93
79
68
60
53
48
44
40
37
34
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
%Fixture
1775
2479
3657
4632
4632
40.4
56.3
83.1
105.3
105.3
38.3
53.5
79.0
100.0
100.0
3538
3281
2542
1786
1322
915
714
613
564
543
537
534
534
534
535
473
312
135
0
20%
122
100
83
71
62
55
49
44
41
37
35
Lumens
3538
3409
2970
2349
1777
1376
1020
752
596
504
449
416
396
378
364
353
289
131
0
Average
0-Deg
cd/sm
22714
20798
17703
12139
3210
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
Average
45-Deg
cd/sm
5113
5203
6416
9784
10782
10%
30 10
107
93
81
71
64
57
52
48
44
41
38
107
91
77
67
59
53
48
43
40
37
34
0%
0
105
88
75
65
57
51
46
42
38
35
33
Average
90-Deg
cd/sm
5509
6678
9064
13110
11111
ADF060486
10/06/2008 10:47:32 AM
ORDERING INFORMATION
S A M P L E N U M B E R : M B - 1 3 2 - N B - U N V- E B 8 1- U
Tandem
Blank=
4' Length
8T=
8' Length
Ballast Type (1)
T5 Systems
EBT =T5 Linear Electronic Program Rapid
Start. Total Harmonic Distortion < 10%(5)
No. of Ballast
1 or 2
EHT =T5 Linear Electronic Program Rapid Start
High Ambient.
Total Harmonic Distortion < 10%(6)
No. of Ballast
1 or 2
DIM=Consult Factory(6)
Series
MB= Micro-Bay
Number of Lamps
(Not included)
1=1 Lamp
2=2 Lamps
Lamp Types
54T5=54W T5HO (4') Lamp
Reflector
FB=Focus Beam
TB=Task Beam (Medium)
NB=Normal Beam
Voltage
UNV=Universal 120-277 Voltage
UNC=Universal 347/480 Voltage(4)
Options
PI/CPI=Plug-In (1, 2 or 3)
(see ordering information below)
C3=3' Power Cord
C6=6' Power Cord
PC3-=3' Power Cord & Plug (Specify Voltage) (3)
PC6-=6' Power Cord & Plug (Specify Voltage) (3)
Packaging
U=Unit Pack
Accessories (order separately)
GRIPPLE-Y- =Y Mounting Toggle, #2 Cable (Specify 10' or 30')
(Row Mount)
GRIPPLE-TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30')
(Stand Alone)
MB-EXT-LONG-CONN-KIT-U=Rigid Connector Support for Continuous
Channel Installation
MS=Aisle Coverage Motion Sensor (3) (6)
MSO=360° Coverage Motion Sensor (3) (6)
MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage Motion Sensor,
Center Mount Hardware, 120/277V
MB-SENSOR-KIT-END/MT-U=Aisle Coverage Motion Sensor, End
Mount Hardware, 120/277V
MB-SENSOR-KIT-END/480V-U=Aisle Coverage Motion Sensor,
End Mount Hardware, 480V
Options
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed (2)
NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Voltage to be specified with emergency ballast option.(3) Voltage must be specified when ordered with plugs, motion or
emergency ballasts. (4) 2 lamp ballast configurations only in UNC versions. (6) Dimming ballast must be specified at time of order.
PI OPTION ORDER INFORMATION
Catalog
Number
Suffix
PI 1 BLK
PI 2 BLU
PI 2 BLK
Number of
Circuits
1
2
2
Circuit
Wired To
Ballast
Black
Blue
Black
PI 3 RED
PI 3 BLU
PI 3 BLK
3
3
3
Red
Blue
Black
Catalog Numbering System
The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections
together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:
PI-1 = One Circuit - 2 Wires: one black, one white
PI-2 = Two Circuits - 3 Wires: one black, one blue, one white
PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white
When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in
fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using
cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered
separately if PI option is chosen.
PI1 - Single Circuit Plug-In
P I 2 - Tw o C i r c u i t P l u g - I n
SAMPLE NUMBER: PI1BLK-WG
SAMPLE NUMBER: PI2BLK-WG
PI1= Single
Circuit
BLK=Black Hot
NG= No Ground (ground provided
by fixture body)
WG= With Ground (separate
ground wire in harness)
SAMPLE NUMBER: PI3BLK-WG
BLK=Black Hot
BLU=Blue Hot
RED=Red Hot
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
BLK=Black Hot
BLU=Blue Hot
Leave Blank=Single
Neutral
2NEU=Two Neutrals
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
PI3 - Three Circuit Plug-In
PI3= Three
Circuit
PI2= Two
Circuit
Leave Blank=Single
Neutral
2NEU=Two Neutrals
NG= No Ground
(ground provided by
fixture body)
WG= With Ground
(separate ground wire
in harness)
NG= No Ground (ground provided
by fixture body)
WG= With Ground (separate
ground wire in harness)
SHIPPING INFORMATION
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Catalog No.
Wt.
MB-154T5
6 lbs.
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADF060486
10/06/2008 10:47:32 AM