Transcript
DataLink 600 Category 7+ S/FTP 100 Ohm Horizontal LAN Cables Tested to 1000 MHz FREQ. Insertion Loss NEXT PS NEXT EL FEXT PS EL FEXT RL TCL EL-TCTL PS ANEXT PS AFEXT MHz dB/100m dB dB dB/100m dB/100m dB dB dB dB dB 1 4 8 10 16 20 25 31.25 62.5 100 150 200 250 300 400 500 600 700 800 1000 Max Min NS 3.74 5.24 5.86 7.41 8.29 9.29 10.41 14.88 19.02 23.56 27.47 30.97 34.19 40.01 45.26 50.10 54.63 58.92 66.93 78.0 78.0 78.0 78.0 78.0 78.0 78.0 78.0 75.5 72.4 69.8 67.9 66.4 65.2 63.4 61.9 60.7 59.7 58.9 57.4 Min 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 72.5 69.4 66.8 64.9 63.4 62.2 60.4 58.9 57.7 56.7 55.9 54.4 Min Min Min Min Min Min Min 78.0 83.3 77.2 75.3 71.2 69.3 67.3 65.4 59.4 55.3 51.8 49.3 47.3 45.8 43.3 41.3 39.7 38.4 37.2 35.3 75.0 80.3 74.2 72.3 68.2 66.3 64.3 62.4 56.4 52.3 48.8 46.3 44.3 42.8 40.3 38.3 36.7 35.4 34.2 32.3 20.0 23.0 24.5 25.0 26.0 25.0 24.3 23.6 21.5 20.1 18.9 18.0 17.3 17.3 17.3 17.3 17.3 16.6 16.1 15.1 40.0 40.0 40.0 40.0 38.0 37.0 36.0 35.1 32.0 30.0 28.2 27.0 26.0 NS NS NS NS NS NS NS 35.0 23.0 16.9 15.0 10.9 9.0 7.0 5.1 NS NS NS NS NS NS NS NS NS NS NS NS 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 65.8 64.8 64.0 62.5 67.0 67.0 67.0 67.0 67.0 67.0 65.2 63.3 57.3 53.2 49.7 47.2 45.2 43.7 41.2 39.2 37.6 36.3 35.1 33.2 DataLink 600 Transmission Properties and Electrical Specifications Note: Values above 600Mhz are nominal,for reference only Characteristic Impedance DC Resistance Resistance unbalance Capacitance Cap. Unbalance (wire to ground) Voltage rating Dielectric strength Velocity of Propagation (NVP) Propagation delay Delay Skew Insulation Resistance Coupling attenuation Screening Attenuation Transfer Impedance 100±5 Ohm @ 1-1000 MHz 93.0 Ohm/Km max. 2% max. 45 pF/m nom. @ 1 KHz 1500 pF/Km max. @ 1 KHz. 72 Vdc max. 700 Volts/1 minute min rms 77-80% 500 + 36/f1/2 @ 1-1000 MHz. 25 nS/100m max @ 1-1000 MHz. 5000 MegaOhm•Km min. @ 500 Vdc 85 dB min @ 30-100 MHz 85-20Log(f/100) @100-600 MHz 60 dB min @ 30-600 MHz 10 mOhm/m max @ 1-30 MHz 30 MOhm/m max @ 30-100 MHz Ordering Information HCS P/N 4x2x23# S/FTP CAT 7+ PVC Grey, Tested to 1000 MHz 4x2x23# S/FTP CAT 7+ PVC Grey, Tested to 1000 MHz 4x2x23# S/FTP CAT 7+ LS0H Grey, Tested to 1000 MHz 4x2x23# S/FTP CAT 7+ LS0H Grey, Tested to 1000 MHz 2x(4x2x23#) CAT 7+ S/FTP PVC Grey,Tested to 1000 MHz 2x(4x2x23#) CAT 7+ S/FTP PVC Grey,Tested to 1000 MHz 2x(4x2x23#) CAT 7+ S/FTP LS0H Grey, Tested to 1000 MHz 2x(4x2x23#) CAT 7+ S/FTP LS0H Grey, Tested to 1000 MHz Flame Test conformance F=0: IEC 60332-1 F=C: IEC 60332-3-24 OD mm Weight Kg/Km Cal. Value Kj/m 7.0 7.0 7.0 7.0 7.0x14.2 7.0x14.2 7.0x14.2 7.0x14.2 48 48 48 48 100 100 100 100 660 660 660 660 1320 1320 1320 1320 F=D: IEC 60332-3-25 Note: Standard jacket color: Light Gray RAL 7035. Other colors available upon request. Connecting Networks.™ www.hescs.com Packaging 500m Drum 1000m Drum 500m Drum 1000m Drum 500m Drum 1000m Drum 500m Drum 1000m Drum Notes FIG-8 FIG-8 FIG-8 FIG-8 HES Cabling Systems H07-F0411-DP H07-F0411-DM H07-F0412-DP H07-F0412-DM H07-F0813-DP H07-F0813-DM H07-F0814-DP H07-F0814-DM Description 95