 This guide contains step-by-step instructions for installing
Microsoft® Windows™ Server 2003/Microsoft™ Windows™ 2000
Advanced Server or Red Hat” Linux on a single RAID volume
using available disks. If you plan to use a different operating
system, need a more advanced RAID configuration, or need
safety and regulatory information, you should refer to the
Hardware and Software Guides. You can find these guides
on the Resource CD accompanying the Intel* RAID Controller
SRCS28X. These guides and other supporting documents
(including a list of supported server boards) are also located on
the web at; http://support.intel.com/support/motherboards/server.
If you are not familiar with ESD (Electrostatic Discharge)
procedures used during system integration, please see
your Hardware Guide for complete ESD procedures.
For more details on Intel® RAID controllers please see:
www.intel.com/go/serverbuilder
What you will need
- SATA hard disk drives
- Intel® RAID Controller SRCS28X
- Server board with a PCI-X compatible slot (recommend use of a 64-bit, 133 MHz slot)
- Intel® RAID Controller SRCS28X Resource CD
Important Information
You can find the Hardware and Software Guides on the Resource CD that
accompanied the Intel® RAID Controller SRCS28X.
These guides and other supporting documents (including a list of
Building Value With Intel
Alarm Information
Server Products, Programs and Support
Get the high-value server solutions you need by Intel® ServerBuilder is your one-stop shop For information about the alarms
taking advantage of the outstanding value Intel for information about all of Intel's Server and how to turn silence or disable
provides to system integrators: Building Blocks such as: the alarm, see the reverse side
* High-quality server building blocks e Product information including product of this document.
e Extensive breadth of server building blocks briefs and technical product
e Solutions and tools to enable e-Business specifications
* Intel? Server Management e Sales tools such as videos and
* Comprehensive training services presentations
* Worldwide 24x7 technical support e Training information, such as the Intel®
(AT&T Country Code + 866-655-6565)' Online Learning Center
e World-class service, including a three-year e Support Information and much more
limited warranty and Advanced Warranty
Replacement!
For more information on Intel's added-value ‘Available only to Intel® Channel Program
server offerings, visit the Intel® ServerBuilder Members, part of Intel® e-Business Network.
website at: www.intel.com/go/serverbuilder
Install Battery Backup Install the Intel® Attach SATA Cables
Module (optional) RAID Controller
oO Plug battery cable into SRCS28X IN the
module connector as shown. Server board
Position module as shown and
plug into RAID card connector.
O Attach With three screws from 1. Power down the system, 1. Connect one end of the SATA cable
back side of RAID card. See your disconnect power cord(s), to SATA connector located on the
Battery Backup Module documentation and remove the system cover. Intel® RAID Controller SRCS28X.
for additional installation information.
2. Install the Intel® RAID Note: Refer to the "Intel® RAID
Controller SRCS28X into an Controller SRCS28X Diagram" on
available PCI-X slot. Side 2 of this Quick Start User's Guide
for SATA connector locations.
Note: See your Server Chassis
The following RAID adapters were detected in your system-Please select one and press start to
configure.
Adapter Haj.
intel Intell) RAID BIOS Console Configuration Hizard
Configuration Hizard guides you through the steps for configuring the RAID
system easily and efficiently. The steps are as follows:
1. Array definitions Group physical drives into arrays.
Zo Logical Drive definitions Define logical drives using those arrays.
3. Conficuration Preview Preview configuration before it is saved.
Please choose appropriate contiguration type:
© Clear Configuration Allows wou to clear existing configuration only.
fet Mew Configuration Clears the existing configuration. If you have any existing data
Ш in the earlier defined drives, the data will be lost.
{Add Configuration Retains the old configuration and then adds new drives to the
configuration: This is the safest operation
as it does not result in any data loss.
MAMMA - C89413-002
mip Next | Xx Cancel |
Select Appropriate action. | Step 1/5 |
- Operating System: (Microsoft* Windows* Server 2003/Microsoft* Windows* 2000 supported server boards) are located on the web at: doc a n for acc 2 connect я © oy mo of the fi
Advanced Server or Red Hat* Linux) Installation Media http://support.intel.com/support/motherboards/server. card installation procedure(s). cable 10 1he fives or arive
enclosure.
®
Use the Intel® RAID BIOS Console to Create a RAID Volume
Note: As necessary, refer to “Choosing the Right RAID Level” on Side 2 4. After a brief pause, the RAID BIOS Console screen will appear. 6. For this example, we used Custom Configuration. Click Next. 8. You can define further arrays or click Accept Arrays if finished
of this Quick Start User's Guide for a brief description of RAID levels. Click on Configuration Wizard. (For further information, refer to the Software Guide on the and then click Next.
1. Power on the system and press <Ctrl> + <G> when the screen PESTE Console Logical Configuration Resource CD.) Intel(r) RAID BIOS Console Config Wizard - Array definition |
й [|
below appears. a Al Bl E ES | E UE 2] Inteltr) RAID BIOS Console Configuration Hizard `
И Array Definition: To add drives to an Array, hold Control key while selecting
RAID Controller BIOS Version C480 (Build December 15, 2083) AID BIOS Oe Wizard can define the most efficient configuration for your systentAuto Configuration), Ready drives and click on Accept Array. Drive addition can be
TE ; ; if ienced user, Hizard can tak through the st ; ; |
EEE AE A я taper Properties Physical Drives | or ou are au user, Hizard can take you through the steps undone by selecting the Reclain button
[ PCI 4/2 1 DRAM =64HB (SDRAM) 2 = |
МИЛО LR SO ee LIE WDZ500J D-DOFYBO = ооо — el Custom Configuration: Lllows you to define all aspects of the ПО vv = = 0 - ООО НОНО
Г Pel 1 7 Korb = rt O Uh 4 Scan Devices = AU Online: 233470 BB WBC WPR2S00JD-00FY BO ar EE configuration, arrays, logical drives, and € EE | Array O :RO=253080MB, R5=715410MB
[ PCI 4/2 1 Port-3 —- WDC [Near O ee dc) : AC: Online: 239470 ME WDC WDZ500JE- OOFYBO | their parameters. Or Online: 238470 ME @ Fort OÙ: Online: 2364 OME
| oe eco lear) To of Te Thee ER host adapter, @ Logical Drives : AO: Online: 232470 MEWDE — WDpes0ChTD- O0FTEO | © Auto Configuration: With Redundancy Lutomatically creates redundant arrays and 1: online: 235470 ME ea Port i: Online: 235470ME6
: A0: Online: 238470 MB WDC WDZ500JP 0OFYEO Î (Recommended) logical drives, where possible, and sets their 2: Online: 238470 HE es Fort 2:0nline: 235470MB
@ Physical Drives parameters. 3: Online: 238470 ME @ Port 3: Online: 238470MB
| | Auto Conficuration: Without Redundancy Aiutomatically creates non-redundant arrays
@ Configuration Wizard | and logical drives, and sets their parameters.
@ Ldapter Selection |
>>>>>> Press <CtrI><G> to enter the RAID BIOS Console <<<<<<< [- Physical View | ky Reset . § Accept Array | 4 Reclaim |
opyright (c) LSI Logic Corp. All rights reserved * LS ias ME: Optimal |
@ Exit | qu Back | mp Next | X Cancel |
. . | An Back mig Next | > Cancel
2. The following two messages will appear at the bottom of the |
screen: “Intel® RAID BIOS Console will start after POST completes”, |
“Please wait to start Intel® RAID BIOS Console ...” |
|} Select Appropriate configuration type. Step 2/5 | Select Ready drives and add to array. Step 3/5 |
3. When Intel® RAID BIOS Console starts, it will display the Intel®
RAID Controller SRCS28X installed in the system.
Click on the "Adapter No." radio button, then click Start. | 7. Add physical drives to the array by holding the control key while 9. Select the RAID Level from the pull-down box. Select the Stripe
sen 5. Select New Configuration and click Next. clicking on ready drives. Once you have selected all of the drives Size. Enter in the size of the logical drive. Click Accept.
you wish to add to the array, click Accept Array and then click Next.
Define Logical Drives using the arrays defined in the
Array Definition: To add drives to an Array, hold Control key while selecting Previous screen.
Ready drives and click on Accept Array. Drive addition can be
intel Inteltr) RAID BIOS Console Config Wizard — Logical Drive definition
Intel(r) RAID BIOS Console Config Hizard — Array definition
. . Logical Drive 8 Configuration
undone by selecting the Reclaim button. 9 9
RAID Level | RAIDS "| @frray 0 :RO-S53600ME, R5=715410HE
Stripe Size | 64 EB w
Read Policy | |[HoReadähead w] Maximum size of drive
Write Policy [rice In] located here
Cache Policy | Direct Io - w
Span | Disable w
ry Reset $ Accept Array | 4 Reclaim | Array n: RAID Level = Size Available
= Select Size | 15410 | "ME
4n Back | un Next | > Cancel |
+ iccept кз Reset |
41 Back | mig Мент | x Cancel |
Select Ready drives and add to array. Step 3/5 | Choose parameters for new Logical Drive. | Step 4/5 |
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2005, Intel Corporation. All rights reserved.
Related documents