 | 1092
| 1070
600 0.37
485HOLE TO HOLE
750 М ARNE AT FACTORY SETTING SQUARE / Ц
A
I Г
| | FOR RM PDU | | | o a|| |!
| | MOUNTING NUE ° | | | 1 1
| | DETAILS IN 8 | | | 44 | ÍA 160
| | REF. VIEW A | ЮО a I TERN 1 т
1 о al
i | I 1
neo 1000 — NE — 1000 — | | NT SDE м
! MMT DERFORATED | MINIMUM SERVICE MINIMUM SERVICE | BRACES 1 1
MATERIAL AND COOLING í AND COOLING ~ THIS PANEL IS Hoo
FOR AR FLOW CLEARANCE 0 © CLEARANCE НТН PERFORATED : : о
| 00000 5 | | 7 1
| 00000 WIE LE | FOR AR, FLOW o o
O2 i | \ I 1
1 1 NA a al
| 0000 | 102 ; ; | 9 0 1 | 1
2258 | | —3 SIDE D 0 | | p 1 I
TOTAL OPEN AREA E
| 9004.10 SQCM | BRACES Pod | A | с > о Ue
| во | | т | OOOOO 1 1 |
OPEN AREA = If = о о
y | e U SPACE | E с В | | | 311 1 ! 200
187.60 SQ.CM) TOTAL OPEN AREA 5 PLACES 1 ! 5 PLACES
В | | В | | 9892.50 SQ.CM 1 т
| о о
| | | | | (OPEN AREA 1 1
PER U SPACE
| | 958 al | 206.10 SQ.CM) Е Cs
2 PLACES | о о
| | | | | | 1 1
|! ! ! ! а а
a | | 2222
Ih
| | i | | | т т
36 9 a с
FL ' || 0 à
o o Ts I I
al al
—1 5| [8
FRONT VIEW SIDE VIEW REAR VIEW ! !
I I
1275 al |9
„7 — Xx VA Ш > | 0
N > ° 374 = Un
V 111 1 1
— I I
| 3 PLACES al |
E HIE
a 0000000 : = o 6
215 RE e
105 Е т
DEPTH a я я "5 о o
W/O DOORS x x alo
7 Pi: E il JL
a о о o о п
à a ooooooan a — 114
— — NOTES: VIEW=A
/ 1. ALL DIMENSIONS ARE IN MILLIMETERS. RMPDU MOUNTING DETAILS
139° MA / 2. CABLE ENTRY IS TOP OR BOTTOM OF UNIT.
738 3 PLACES / 3. FRONT AND REAR SERVICE ACCESS.
/ 4, NET WEIGHT OF UNIT IS 169 Ko.
1 „7 5. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS.
«a 2 pd
-_ | ——-
1294—
1559 THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: NETSHELTER SX 48U ENCLOSURE | PWE NO: AR3157 — MM1 REV. — ©
“У PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT 750mm W x 1070mm D APC
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART
TOP VIEW AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITH SIDES DRAWN: BALAMURUGAN | | 07/02/06
DOORS FULLY OPEN WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING MAIN MECHANICAL CHECKED: J.BERGESCH 23/02/06 PROJECTION AMERICAN POWER CONVERSION
(DOORS FULLY OPEN) IS BASED UPON LATEST AVAILABLE INFORMATION AND IS A 132 FAIRGROUNDS RD
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING | SHEET 1 OF 3 |ENGINEER: C.LARSEN/S.WAGH 23/02/06 | 1 WEST KINGSTON, RI 02892
75 240
2 OPENINGS - OPENING REAR
SN,
еще ое В ов al oo oo] — 92 = = = = = = = = =
TO 0 So OPENING 1 © o J
I | = ое es | I - 650 - |
0 De ~ FRAME OPENNG ————— | 178
164 о о ое | 165 ‘ (FRONT AND REAR) > REAR
2 OPENINGS | a OH 9999000 © | | | CLEARANCE
| co E 0 eo | — | — !
о 0 0 о JA o À
= es ]
oO Do 895 > 20 9
5 0 о в o OPENING 193 |
co D © a BETWEEN FRAME
- © 1 © 7 VERTICALS 128
892 ео о в ; - SIDE "OU”
OPENING ое оп Don 54 SPACE — 737
W/O ео y Doa 5 OPENINGS 455 RAIL TO RAIL
ROOF о п 1608) сс SIDE OPENING 476 (OUTSIDE)
- u ов BETWEEN RAILS FOR CAN BE ADJUSTED
оо 1. lL AT FACTORY || NETWORKING {| TO 934 MAX AND
3 © ов | | SETTING APPLICATIONS 540 MIN
j WITH 6 INCREMENTS
oO Do y 171
о О О o | D OPENINGS 465
= Bb Do y HOLE TO HOLE
co 0 Doo — PER EIA 310 7
о О 0D OO oOo Oo oOo ada О о o 451 5
nc | ое MIN OPENING
| s 0 o Do | | DM! PER EIA 310 ‘ |
е®-® ° 2.00 BS |
aE e !
> a 51 | UL ——————
FRAME
717 VERTICAL FRONT 64
OPENING W/O ROOF — FRONT BEZEL
CLEARANCE
CAN BE ADJUSTED |
TO 800 MAX AND
TOP VIEW SECTION B-8 51 MIN
CABLE OPENINGS (VIEW FROM INSIDE CABINET NCREMENTS
(COVERS REMOVED) LOOKING DOWN
NOTES: бет ог ВЕС FONT CoMETON AD <p por | | NETSHELTER $ 480 ENCLOSURE |” 7 AR3157—MM2 — APC
1. ALL DIMENSIONS ARE IN MILLIMETERS. BE COPED, REPRODUCED OF USED IN WHOLE OR IN PART WITH SIDES DRAM onion [ojos]
2. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS. Co TOP AND SECTION VIEWS |CHECKED: JBERGESCH | [28/02/06 | SUN CORSO
SUBJECT TO CHANCE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING |SHEET 2 0F 3 ENGINEER: C.LARSEN/S.WAGH 23/02/06 | 1 WEST KINGSTON, RI 02892
/\
280 190 PALLET BRACKET (2) 245 260 /\
BOLT-DOWN BRACKET (4)
19 FRONT ADJUSTABLE LEVELING FEET (4) —18
| CAE / FRONT ADJUSTABLE LEVELING FEET (4)
| — 1 ©
© © O
о © O
29 a N
1024
LEVELLING FEET
1154 1152 CENTER TO
107 CENTER
717
776 BOTTOM OPENING 1024 1107 949
ne 4 837 mon 4 | CENTER TO
CENTER
70 —+—
| Г = —
[ al ой _ © 0) | © _ _ _ o
9 99900 у ое о о вю
о © O O OO 5 © 0 ® o po Е
0 O0, ‘ o| = O
REAR REAR
L 1090 - 330 -
722 551
CASTERS
CENTER TO
CETNER
BOTTOM VIEW BOTTOM VIEW
(WITH PALLET BRACKETS (WITH OPTIONAL BOLT—DOWN BRACKETS
(CAN BE USED FOR ANCHORING) FOR_ANCHORING)
NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. TMS DRAM AND SPECFICNTONS HEREN ARE THE er LE NETSHELTER SX 48U ENCLOSURE | 2" NO: AR3157 — MM3 REV. — ©
/\ 2 ANCHORING BRACKETS CAN BE INSTALLED EITHER INSIDE OR OUTSIDE THE NETSHELTER. BE COPED, REPRODUCED OR USED IN WHOLE DR IN PART, 750mm W x 1070mm Docu ARUN | 7/02/06 APC
3. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. NTC WIEN PERSON SOM AFC: Te AVI BOTTOM VIEWS CHECKED овен | з/у | РОСТО | re ss cos
SUBJECT TO CHANGE WITHOUT NOTICE, PROJECT: SUBMITTAL DRAWING [SHEET 3 OF 3 |ENGINEER: C.LARSEN/S.WAGH 23/02/06 |" - WEST KINGSTON, RI 02892
156
CABLE TROUGH _ 505. PARTITIONS
(OPTIONAL) (OPTIONAL)
tN ( | ——
IY | | У | лы
110 - Но
| 2442
: : Ol | A
FRONT_VIEW SIDE VIEW REAR VIEW
=
72
TYP
ADJUSTABILITY RANG
ENLARGED VIEW
(Ob ooooooao
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS.
: : 2. THIS DRAWING REPRESENTS NETSHELTER WITH OPTIONAL TROUGH AND PARTITION
==. ACCESSORIES.
= — A 3. AVAILABLE CABLING AREA CAN BE ADJUSTED TO MEET CUSTOMERS REQUIREMENTS.
4 INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES.
TOP VIEW
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: DWG NO: AR31 57—MM4 er ®
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT NETSHELTER SX 48U — NPC
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, ,
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS ENCLOSURE WITH SIDES, 30Wx42D | DRAWN BY: B ZAHN 03/22/06
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING TROUGH AND PARTITION VIEWS CHECKED BY: J BERGESCH 04/05/06 AMERICAN POWER CONVERSION
IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 4 OF4 | ENGINEER: C LARSEN/S WAGH 04/05/06 WEST KINGSTON, RI 02892