Download APC NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure with Sides Black

Transcript
 600
MINIMUM COOLING
1991
THIS PANEL IS
CONSTRUCTED
WITH PERFORATED
MATERIAL
FOR ARR FLOW
C0000
C )
C )
DY Y Y
UJ -«—
PER U SPACE
|
|
|
|
|
|
| TOTAL OPEN AREA
|
|
| 141.20 SQ.CM)
|
|
|
|
|
|
|
|
|
|
|
|
5930.20 SQ.CM ||
E
(OPEN AREA
|
|
|
D
——.—
FRONT VIEW
1021
TT >
>, /
Y i
53 9 De
27 : Е
1051 ея о
DEPTH 0 Ds
W/O DOORS ао ое
o@9 - ó - Po
/
139" MAX /
588 3 PLACES /
~ ~~ — _ р
-—1244
1034——
TOP VIEW
(DOORS FULLY OPEN)
FOR RM PDU —
MOUNTING
DETAILS
REF. VIEW A
1000
AND COOLING
CLEARANCE
102
— 3 SIDE
BRACES
1092
—., 81 HOLE-TO-HOLE _
AT FACTORY SETTING
— — |
MINIMUM SERVICE
1000
MINIMUM SERVICE
AND COOLING
CLEARANCE
[-— —
2 PLACES
SIDE VIEW
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS.
THIS PANEL IS
CONSTRUCTED
WITH PERFORATED
MATERIAL
| FOR AR FLOW
! \ 00000
С )
С )
С )
С )
00000
TOTAL OPEN AREA
6689.80 SQ.CM
(OPEN AREA
PER U SPACE
159.30 SQ.CM)
REAR VIEW
2. CABLE ENTRY IS TOP OR BOTTOM OF UNIT.
3. FRONT AND REAR SERVICE ACCESS.
4. NET WEIGHT OF UNIT IS 124.5 Kg.
5. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS.
0.37
O=0=0=0=0=0=0=0=0=0=0=0=0=0=0=1[
AD
<
ьо=еое= соо ое ое ое ое 02 0 = о = о = 0 = 0 = 0 =
|
1
SQUARE / 107
_ {
el HE
44 Q o: 75
CONTINUOUS
PATTERN
EXCEPT
AT SIDE |
BRACES
o 0
I
1
a
311 `
5 PALCES 1956
| ñ ñ
0 0
Io 1
Tri ITA |
|! 200
| |1 4 PLACES
| o| Je |
111 ao
3 PLACES 0 Ce
Ti
If 11
eN
| |
I
95 0 0
a SL
| SL )?)| Я
| |
114 i |
y |
VIEW=A
RMPDU MOUNTING DETAILS
SUBJECT TO CHANGE WITHOUT NOTICE.
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART,
AS THE BASIS FOR THE MANUFACTURE OR SALE OF [TEMS
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING
IS BASED UPON LATEST AVAILABLE INFORMATION AND IS
ME NETSHELTER SX 42U ENCLOSURE | PS NO: AR3100 — ММ! [®_
WITH SIDES,
600mm W x 1070mm D DRAWN: BALAMURUGAN 07/02/06
MAIN MECHANICAL CHECKED: JMATTLIN 15/03/06 Pg
Г
PROJECT: SUBMITTAL DRAWING |SHEET 1 OF 3 (ENGINEER: C.LARSEN/SWAGH | |15/озуов |< —
APC
AMERICAN POWER CONVERSION
132 FAIRGROUNDS RD
WEST KINGSTON, RI 02892
240
75 E. - —
2 OPENINGS 3 OPENING REAR
(ob pea =. = E
еб ’ es a 500 e !
À Г 7 À
В oO о в = FRAME OPENING _ SAR
о О О о y
2 0PENNGS|| kb 0905000080 81 185 (FRONT de REAR) | CLEARANCE
| Oe 0 OO | de НН |
е O О о 895
зо о о в OPENING
do 0 О où BETWEEN -
це 0 0 op FRAME —— 49
o 0 oO ok VERTICALS
Tm a 0 Cl O |x 51
892 5 0 o ol —| | -=— SIDE ”0U” 737
OPENING ae О 054 1 54 SPACE RAIL TO RAIL
W/0 оо о в 5 OPENINGS 550 (OUTSIDE)
ROOF о Do OPENING CAN BE ADJUSTED
зе © Dor BETWEEN TO 934 MAX AND
loa a of | RAILS +05 540 MIN
o © goal 177 AT FACTORY - SER EN 390. —] WITH 6 INCREMENTS
IE: D sf || 5 OPENINGS SETTING
mao О О a | y
oO g as 450 MIN OPENING
M UoooooooŸÿ ©” PER ElA 310
so go [= авс о oO
| зв | |. | | À |
0 @:€ 5 2.00 NY
KT > Ñ JD 91 | =) ]
FRAME
567 VERTICAL FRONT
OPENING W/O ROOF — 64
FRONT BEZEL
CLEARANCE
CAN BE ADJUSTED |
TOP VIEW SECTION 8-8 T0 800 MAX AND
CABLE OPENINGS (VIEW FROM INSIDE CABINET, WITH 6
(COVERS REMOVED) LOOKING DOWN) INCREMENTS
NOTES: |" ese ox 420 ENCIOSURE DONE ARS100 — MM2 [7 —
1. ALL DIMENSIONS ARE IN MILLIMETERS. BE COPED, REPRODUCED OF USED IN WHOLE OR IN PART 600mm. W. x 1070mm D [oran BALAMURUGAN | To7/02/06
2. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS. CL eye TOP AND SECTION VIEWS |CHECKED: JMRTILN | 18/03/06 | "LOE | MN OWN
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING -|SHEET 2 0F 3 ENGINEER: C.LARSEN/S.WAGH 15/03/06 Y WEST KINGSTON, RI 02892
/\
~— 205 ——— 190 PALLET BRACKET (2) 301T-DOWN A.
ADJUSTABLE LEVELING FEET (4)
FRONT 7 ADJUSTABLE LEVELING FEET (4)
A |
1022
1106 1152 1151 LEVELING FEET
67 CENTER TO
LE CENTER
119 BOTTOM OPENING 1022 1105 941
CASTERS
729 831 776 CENTER TO
CENTER
70 =—
y
Y 4 N Y Г
> o _ © 0 Oo _ | _ ©
- © © ©_0© ye. 9 e eo © y
2 о ® © © ` 1 Oo % O [© 2 L
| © O © 0, Y Y | O RE R O |
REAR —
-— 190 —
-—— 300 — 401
-— CASTERS —
572 CETNER TO CENTER
BOTTOM VIEW BOTTOM VIEW
(WITH PALLET BRACKETS (WITH OPTIONAL BOLT—-DOWN BRACKETS
(CAN BE USED FOR ANCHORING)) FOR ANCHORING)
NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. THIS DRAMNG AND SPECIFICKTONS HEREN ARE THE | Ш MILE: NETSHELTER SX 42U ENCLOSURE | PS NO: AR3100 — MM3 REV. ®
/\ 2 ANCHORING BRACKETS CAN BE INSTALLED EITHER INSIDE OR OUTSIDE THE NETSHELTER. BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITH SIDES, DRAWN: BALAMURUCAN 07/02/06 APC
WHO REN PERMISSION: FROM APC. THIS DRM i oom mon vee ) CHECKED: J.MATTLIN 15/03/06 | PROJECTION AMERICAN POWER CONVERSION
3. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. UN ; , 103/06 | TT PAN PONER COMER
SUBJECT TO CHANCE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING [SHEET 3 OF 3 |ENGINEER: C.LARSEN/S.WAGH 15/03/06 | [0 WEST KINGSTON, RI 02892
1.42
36
TYP
ADJUSTABILITY RANGE
ENLARGED VIEW
NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
A 2. THIS DRAWING REPRESENTS NETSHELTER WITH OPTIONAL TROUGH AND PARTITION
ACCESSORIES. PARTITION CABLING AREA CAN BE ADJUSTED TO MEET CUSTOMERS
REQUIREMENTS.
3 INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES.
(0 ooooooo)
TOP VIEW
ee
\./
: :
FRONT VIEW
PARTITIÓNS —
(OPTIONAL)
| /
[a ———
19.88
— 6.15
505] [156]
CABLE TROUGH
7 (OPTIONAL) \
4.78
[121]
SUBJECT TO CHANGE WITHOUT NOTICE.
PROJECT: SUBMITTAL DRAWINGS |SHEET 4 0F4 | ENGINEER:
C LARSEN/S WAGH
03/23/06
| || || 7.23
| | OI, [184]
4.33 |
[110]
|
85.65
| [2175]
|
= LE |
ww EW - — wd 1
SIDE VIEW REAR VIEW
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: DWG NO: REV. ®
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT NETSHELTER SX 42U ARS100—MM4 | — NPC
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART,
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS ENCLOSURE WITH SIDES, 24Wx42DC | DRAWN BY: B ZAHN 03/21/06
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING WIRE TROUGH AND PARTITIONS VIEWS | CHECKED Br: J MATILIN 03/23/06) - AMERICAN PONER CONVERSION
IS BASED UPON LATEST AVAILABLE INFORMATION AND IS
132 FAIRGROUNDS RD
WEST KINGSTON, RI 02892
Related documents