Transcript
SIZE:84*145MM SAFETY PRECAUTIONS Advanced Upper Arm Blood Pressure Monitor Model 1137 Instruction Manual OVERVIEW QUICK-START GUIDE • Babies, young children or individuals who cannot express their consent are not suitable for blood pressure measurement. Avoid smoking, eating or exercising for 30 minutes before taking a measurement. • Individuals with serious arteriosclerosis are not suitable for blood pressure measurement. Measurement may be taken on either arm; however, if possible, always take measurements on the left arm. • Blood pressure readings may fluctuate during pregnancy. Pregnant women should consult their doctor before taking measurement. • If there are unusual values, please consult your doctor before taking medical action. • Handling batteries properly: - As soon as batteries wear out, replace them with new batteries. - Do not use old and new batteries together. - Align the polarities of batteries correctly. - When the unit will not be used for more than 3 months, remove the batteries. Otherwise, batteries may leak and cause damage to the unit. Never unplug the power cord with wet hands. - Use only the original AC adapter designed for this unit. Average Values (Set) Memory Recall (Up) 1. Sit upright in a chair with your feet on the floor. 1. The battery cover is located on the bottom of the unit. To open the battery cover, push it inward and lift up. - Set the correct date and time before taking a measurement. 2. Insert 4 AA batteries with the polarities as indicated. 1. Press and hold the ”AVG ” button for a few seconds until the Year display flashes. 3. Replace the battery cover. Press it lightly until the lock securely clicks into place. 2. Press the“MEMO ” or ”PAGE ” button to select the current year. 4. Press the “ON/OFF” button to turn on the unit. Then press the “START” button. The cuff will automatically inflate and the measurement will start. Battery Indicator Diastolic Pulse Symbol WHO Light Indicator Memory recall (1~99 readings) Pulse Value Cuff Connector Package Contents Features • Irregular Heartbeat Detector • Blood Pressure Mode and Clock Mode • 4 User / 396 Total Memory • 4 Alarm Clock Settings 5. When the measurement is complete, the cuff will automatically deflate and your systolic and diastolic pressure values and pulse rate will display. • 5 Mode Averaging Function – Hour, Day, Week, Month, and Overall AC Adapter - Reset date and time after replacing batteries. 4 Note: - You will not be able to set the alarm if Clock Function is set to “OFF”. - You can set a maximum of 4 alarms. 4. Follow the same steps to set the Month, Date, Hour and Minute. 5. “ON” and “OFF” will then flash. This is to have the clock display when the unit is not in use; you can choose Clock Function “ON” or “OFF”. Press “MEMO ” or ” PAGE ” button to select. Press the ”AVG ” button to confirm. Note: If you select Clock Function “ON”, you will continue at the Alarm Setting section. Otherwise, setting will end. Note: - Avoid smoking, eating or exercising for 30 minutes before taking a measurement. - Do not move or talk during measurement. - Measurement may be taken on either arm; however, if possible, always take measurements on the left arm. Note: - Press the “ ” button anytime during clock setting/ alarm setting to start over if an error occurs. - Each alarm lasts 45 seconds, or you can turn it off by pressing the “ ” button. 3.3 User Setting This unit allows a maximum of 4 users to store measurement records in different User Pages. Press “PAGE ” button to switch between User Page 1, 2, 3 and 4. 3.4 Taking a Measurement 3.1 Sitting Correctly 6. To disable Alarm, Press the ”MEMO ” or ”PAGE ” button to select “OFF” and press the ”AVG ” button to confirm. 7. To set 1st Alarm, Press the ”MEMO ” or ”PAGE ” button to select “ON”. Press the “AVG ” button to confirm. 8. When Hour digit flashes, press the “MEMO ” or “ PAGE ” button to select Hour. Press the “AVG ”button to confirm. 9. When Minute digit flashes, press the “MEMO ” or “PAGE ” button to select Minute. Press the “AVG ” button to confirm. 10. Follow the same steps to set the 2nd, 3rd, and 4th Alarms. 4 x AA Alkaline Batteries 5 TAKING A MEASUREMENT 2.4 Setting the Alarm Large Adult Arm Cuff Standard Arm Cuff Main Unit • WHO (World Health Organization)Blood Pressure Indicator with 6-color LED 3 3. Press the “AVG ” button to confirm Year Setting. Note: Remove the batteries when using the AC adaptor. START 3. Pull on the end of the cuff until it wraps securely around your upper arm. Place your arm on a table so that the cuff will be at the same level as your heart. 2 Note: Plug the AC 6V adaptor into the AC adaptor jack located at the side of the device. next to the blood pressure cuff port. POWER 2. Remove thick or tight-fitting clothing from the upper arm. • Operated by 4 AA batteries or AC Adapter (included) 2.3 Setting the Date and Time 2.2 Connect AC Adaptor Systolic Time • Auto-off Power Saving Feature 1137-INS-LAB-RevA09 2.1 Battery Installation Date User 1~4 Memory Read these instructions before using your Blood Pressure Monitor. Save these instructions for future reference. PREPARATION Page Select (Down) Do not move or talk during measurement. • Handling the AC adapter: - Display Monitor 1. Relax. 2. Sit upright in a chair with your feet on the floor. 3. Remove thick or tight-fitting clothing from the upper arm. Do not roll up your sleeve if it is too tight. 4. Place your arm on a table so that the cuff will be at the same level as your heart. 3.2 Applying the Arm Cuff 1. Place your elbow on a table with the palm facing upward. Wrap the arm cuff around the upper left arm. 2. Pull on the end of the cuff until it wraps securely around your upper arm. Do not over tighten the cuff. Allow 1-2 cm or ½ inch between the bottom of the cuff and your elbow joint. 3. Make sure the cuff is at the same level as your heart. (Left arm) Mark cloth 1. Press the “ ” button to turn on the unit. Then press the “START” button. The cuff will automatically inflate and the measurement will start. 2. When the measurement is complete, the cuff will automatically deflate, and your systolic and diastolic pressure values and pulse rate will display. 3. Remove the arm cuff and take note of your measurement results. Note:You can press the “ at any time. ” button to stop measurement 3.5 Heartbeat Readings Besides Systolic and Diastolic values, Pulse will also be displayed after a measurement Pulse 6 7 8 9 Keep 1~2cm between elbow joint and arm cuff 10 SIZE:84*145MM Irregular Heartbeat Regular but Above Normal Heartbeat This unit has a unique feature that alerts user of irregular heartbeat detection during measurement. Note:An irregular heartbeat is defined as a heartbeat rhythm that has a variation of more than 25% from the average rhythm detected during measurement. If the monitor detects a pulse rate above 100 beats per minute during measurement, the monitor will display the pulse value and “HI” symbol alternately. Example: (102 / HI) MEMORY FUNCTIONS 3.6 WHO Light Indicator This unit features a 6-color LED light indicator to display blood pressure level in accordance with the WHO (World Health Organization) classification. mmHg 4.1 View Past Readings Grade 3 hypertension(severe) (Red) Diastolic Pressure 110 If an irregular rhythm occurs twice or more during the same measurement, the display screen will show the pulse value and “IH” symbol alternately. Example: (90 / IH) 105 1. Press the “MEMO ” button to enter memory function. 2. If the User Page is not what you want to view, press the “PAGE ” button to select. 3. Press the “MEMO ” button to display the next sets of values for the user selected. Past readings are displayed from the most recent to the oldest. 4. This blood pressure monitor can store up to 99 sets of past readings for each user (4 x 99). Grade 2 hypertension(moderate) (Yellow) 100 95 90 85 80 Grade 1 hypertension(mild) (Purple) High- normal(Green) Normal (Sky Blue) Optimal(Blue) 120 130 Note:Please consult your doctor if irregular heartbeat occurs often. 140 150 160 170 180 Systolic Pressure Regular but Below Normal Heartbeat WHO Classification Color Optimal -----------------------Blue Normal ------------------------Sky Blue High-normal -----------------Green Mild hypertension ----------Purple Moderate hypertension ---Yellow Severe hypertension -------Red If the monitor detects a pulse rate below 60 beats per minute during measurement, the monitor will display the pulse value and “LO” symbol alternately. Example: (58 / LO) After measurement, the last set of measured values will be saved automatically after measurement when the unit is turned off by pressing “ ” button or by automatic power-off after 3 minutes. mmHg 4.2 View Average Readings Symbol on Display Average Values of 1 h One Hour 1 d One Day 7 d One Week 30 d One Month ALL All Readings 4.3 Delete Past Readings User can delete all the past readings stored in each User Page. 1. Press the “PAGE ” button to select the User Page you want to delete. 2. Press and hold the “MEMO ” & “PAGE ” button simultaneously for 5 seconds. Symbol of “ALL EE” will be displayed and all past readings stored in that User Page will be deleted. 1. Press the “AVG ” button to enter Average function. 2. If the User Page is not what you want to view, press the “PAGE ” button to select. 3. Press the “AVG ” button to view different Average Values. 5 different Average Values are available: WHO Light Indicator Example: If your measurement reading is 122/75, the LED light will display the color in blue. 11 12 TROUBLESHOOTING Symptom Possible Cause Solution No display when you press the Power/Start button Batteries are worn out Replace with new batteries Battery polarities are incorrect Re-align batteries in correct polarities “Err P” displays Failure to inflate Ensure the cuff is properly connected; replace the air tube if it is broken “Err 1” displays Deflating too rapidly Return for service “Err 2” displays Movement during measurement Do not move during measurement Signal interference Remove interfering source, e.g. mobile phones, magnets Incorrect results Measure again “Err 3” displays STORAGE & MAINTENANCE • Keep the unit away from direct sunlight, extreme temperatures, humidity or moisture. • Use a dry or slightly water-dampened cloth to clean the unit. • Do not use alcohol, benzene, thinner or other volatile liquids to clean the unit. • Do not wash the arm cuff or expose it to liquid. • Remove the batteries from the unit when it will not be used for more than 3 months. Note: If your problem cannot be solved by the above, consult a GF Health Products, Inc. representative. Refer to the Warranty section of this manual for more information. DO NOT disassemble the unit. 13 SPECIFICATIONS Model No. Measurement Method Measurement Range 1137 Oscillometric Pressure: 20 – 280 mmHg Pulse Rate: 40 – 195 beats/min Accuracy Pressure: +/- 3 mmHg Pulse Rate: +/- 5% Inflation Pump driven Pressure Detection Semi-conductor 4 x AA batteries or AC/DC adaptor Power Supply Auto Power Off 3 minutes after last operation Storage Environment -4°F to 140°F, 10% to 95% RH Operation Environment 50°F to 104°F, 30% to 85% RH 7.7” (L) x 5.0” (W) x 2.4” (H) or External Dimensions 19.5(L) x 12.6(W) x 6.2(H) cm Net Weight 380g (batteries excluded) Cuff Dimensions Standard Cuff accommodates 22-34 cm arm circumference; Large Adult Cuff accommodates up to 42 cm arm circumference Package Contents Standard Cuff, Large Adult Cuff, Instruction Manual, 4 AA alkaline batteries, AC Adapter Note: Specifications are subject to modification without prior notice. 16 17 18 14 15 LIFETIME LIMITED WARRANTY GF Health Products, Inc. offers a lifetime limited warranty on defects in material and workmanship for this product, except as noted below: This product warranty does not cover damage caused by misuse or abuse, the attachment of any unauthorized accessory, alteration to the product, or any other conditions whatsoever that are beyond the control of GF Health Products, Inc. GF Health Products, Inc. shall not be responsible for any type of incidental, consequential, or special damage. To obtain warranty service on your Lumiscope Model 1137 Advanced Upper Arm Blood Pressure Monitor, please contact the Lumiscope Repair Department at 1-800-672-8293. There is a $15 fee for return shipping and handling. Please make checks payable to GF Health Products, Inc. Upon receipt, we will repair or replace, as appropriate, the Advanced Upper Arm Blood Pressure Monitore and return it to you. This warranty does not include any labor charges incurred in replacement part(s) installation or any associated freight or shipping charges to GF Health Products, Inc. Warranty is solely through the Repair Department. Service of this product by anyone other than the Repair Department voids warranty. 19 GF Health Products, Inc. 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www.grahamfield.com © December 2009 GF Health Products, Inc. Made in China