Download Ikelite 6082 underwater camera housing
Transcript
C_GZ-MG 230 IKE L IT E VI D EO CA SE PREPARATION S U P P L E M E N T A L I N S T RU C T I O N S F O R # 6 0 8 1 C a n o n VI X I A H G 2 0 #6 08 2 C ano n V I X I A HG21 P AC K A GE D W I T H H O U S I N G This supplemental set of instructions describes additional features specific to your housing model. Prior to testing the system in the water, please read this supplement along with the general instruction manual to become familiar with its features and functions. Ikelite Video Cases are slightly negative in salt water for stability. This housing has been water pressure tested at the factory and has a working depth of 60m 200. H O U S I N G C O NT R O L S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ • Power On/Off • Start/Stop Zoom • Snap Shot Power SnapShot • Zoom Eyepiece HG21 only • Mode Dial Control • Joy Stick • Joy Stick O Joy Stick Port Joy Stick O • Function Button Function Button • Viewfinder HG21 only Bottom Bar Base Start/Stop Viewfinder HG21 Only Mode Dial Control • External UR/Pro Color Filter • Silicone Lubricant • Lens Shade External Color Filter Lens Shade C O L O R F I L T E R_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The installation and usage of the external UR/Pro color filter is described in the general instruction manual. O P T I O N AL W I D E AN G L E L E N S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The housingMs port accepts optional 67mm threaded waterproof Wide-Angle lenses such as the Ikelite #6420 W-20, Epoque DCL-20 and Inon UWL-100 Type 2. These waterproof lenses secure to the outside of the lens port. Should you elect to use an optional waterproof lens, carefully thread the lens on the front of the lens port on the housing. The lens threads are very fine; DO NOT cross thread. It should screw on very easily. If it is difficult to turn, you are cross threading. E X T E R NA L W I D E - A N G L E P O R T O P T I O N _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The Ikelite #6480 WP-80 is a complete unit, no additional lens or port is required. The Wide Angle Port replaces the housings original port and cannot be removed and replaced underwater. The WP-80 is useable above water for up to 90 degree field of view, underwater for up to 80 degree field of view exact angle of coverage varies with camera model. I N T E R N A L W I D E -A N G L E L E N S O P T I O N _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Special ports are available for use with the Raynox HD-5050 Pro high definition wide-angle lens. optional ports sold separately as dome port #9304 or flat lens port #9304.1. Raynox HD-5050 Pro lens not included. Lens n o t available for purchase through Ikelite. S U PE R - E Y E V I E W F I N D E R H G 2 1 O n ly _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ See exactly what the camera sees underwater using the cameras electronic viewfinder in conjunction with the Ikelite Super-Eye, which is permanently mounted in the eyeport on the clear back plate. The Super-Eye extends the viewfinder image to provide enhanced viewing underwater. L C D M O N IT O R / E X T E R N AL M I R R O R _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The cameras LCD monitor can be viewed thru the rear of the housing. Open the LCD monitor on the camera. Once the camera is secured to the camera tray, press the LCD screen against the shade secured to the back of the housing. M A I N O - R I NG # 0 1 0 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ O-rings last several years if properly maintained. Control seals should not need to be replaced as long as the control shafts are kept clean and lightly lubricated. B AT T E R Y AN D T AP E _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Install a fully charged Canon battery on the camera: BP-809 BP-819 F I NA L P R E P A R A T I O N _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Remove the lens cap, lens hood and cord from the camera. Otherwise, they may interfere with the housing seal. The cameras auto focus feature is utilized underwater. For best results, move in close to your subject and use the wide angle range to shoot thru as little water as possible. The full zoom range is accessible underwater. Chart shows recommended initial settings underwater. CA M ER A Power On/Off Zoom Lever Focus SET T I N G L Camera On L Wide Angle Setting L Auto Mode INSTALLATION continued I N S E R T I N G TH E C A M E R A _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Check that the clean o-ring is properly positioned on the lip of the clear back plate. Place the lid snaps in the open position. Once the camera is mounted to the tray and the camera strap is secured underneath the tray, pull the housing controls out to provide clearance for the camera. Align the back plate with the clear housing and slowly place the back plate against the housing. DO NOT force this installation; if the controls are out of the way and everything is lined up properly, the camera and tray will fit easily inside. Make certain that the tray is completely in the housing. The front should be flat against the housing and NOT tilted on one side. HO US I N G C ON T RO L S_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Slide the housing controls back in place making sure they properly align with the D O NO T fasten one camera functions. Fasten the opposite lid snaps at the same time--D at a time. INSTALLATION C A M E R A T RA Y_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The camera mounts to the tray, which extends from the back plate of the housing. DO NOT remove the tray from the back plate. The camera strap MUST be positioned underneath the camera tray as noted below. 1. Remove camera strap from front loop on the camera. 2. Open the camera LCD screen. 3. Place the camera against the stabilizing pins on the tray. Secure camera with the tripod mounting bolt. The camera should fit easily on the tray and should be parallel with the sides of the tray. 4. Loop the camera strap underneath the camera tray and attach the open end of the strap around the spring pin on the housing back. Operate each control to see how it works with the camera. Some controls such as start/stop will be used frequently. Other controls may seldom be utilized. Refer to your camera owners manual for the proper function of each camera control. Look thru the back to be sure that you can see into the viewfinder. When using the housing controls, especially the start/stop, DO N OT use excessive force because you could damage the camera. C A UT I O N Remove the lens cap and cord from the camera. Otherwise, the cord may interfere with the housing seal. If the housing controls are not properly positioned, they could interfere with the housing seal. 5. Press the LCD screen against the shade on the back. Camera Camera I KE L I T E U N D E R W A T E R S Y S T E M S Front Loop 50 West 33rd Street • PO Box 88100 • Indianapolis, IN 46208 USA • 317.923.4523 Email: [email protected] • www.ikelite.com Front Loop Flap Open Mounting Tray Flap Open Camera Strap Camera Strap Mounting Tray Spring Pin R e m o v e t h e c a m e ra s t r a p f ro m t h e f r o n t l oo p on t h e c a me r a. Lo op t h e ca m er a s t r a p u n d e r n e a t h t h e c a m e r a t r a y a nd a t t a c h t h e o p e n e n d o f t he s t r a p a ro u n d t h e s p r i n g p i n o n t h e h ou s i n g b ac k w i t h t h e f l ap o p en . Spring Pin 6081-82-01-1108