Download Model 700TF(I)
Transcript
Planning Information Model 700TF(I) All Freezer Electronic digital control panel Seamless molding Adjustable spill-proof glass shelves Adjustable door shelves Model 700TF Stationary shelf Location of serial number Magnetic door / drawer gaskets Automatic ice maker (Model 700TFI) Upper freezer storage drawer Front venting with removable kickplate Lower freezer storage drawer Model 700TFI with Ice Maker With the installation of a harness kit, these appliances are Star-K compliant to meet strict religious regulations in conjunction with specific instructions found on star-k.org. You may purchase this harness kit through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. The Sub-Zero Model 700TF and 700TFI integrated design accepts custom wood or stainless steel door and drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes—classic, platinum and carbon. Ergonomically, this unit works—doors above the counter and drawers below counter level. The shallow depth enables you to view everything quickly and you can grab those items and be out of the unit quickly. The drawers have full extension and are a nice way to bring the items to you and not have to bend down and look inside for your package. As with the two drawer freezer this tall cousin can be ordered with or without the automatic ice maker. The door swing must be specified when ordering this unit. Dimensions in parentheses are in millimeters unless otherwise specified. 10/05 1 Planning Information Model 700TF(I) F E AT U R E S Tall freezer unit with upper cabinet freezer and freezer storage drawers Door alarm will let you know with an audible beeping if a door or drawer is left open Model 700TFI has automatic ice maker Top storage drawer has a removable divider Integrated design for "point-of-use" refrigeration anywhere in the home The exclusive dual action hinge has a built-in 90˚ door stop Refrigeration system ensures the best food storage and energy efficiency Meets strict Department of Energy requirements Electronic digital controls are up front and easy to use UL approved for US and Canada Flat to the ceiling bright lighting in cabinet and drawers Adjustable spill-proof glass shelves Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com OVERALL DIMENSIONS 27" 24" (686) (UNIT DIMENSION) (610) (UNIT DIMENSION) TOP OF ROUGH OPENING 14"(356) 13/16" (21) 24" (610) DOOR MOUNTING DETAIL DOOR / DRAWER CLOSED DOOR / DRAWER CLOSED 80"* (2032) 90˚ 3/8" 789/16"* (10) (1995) 19 1/2"* 25 1/2"* (495) (648) 105˚ 25 7/8" (657) 131/4" 1/2" (337) (13) DRAWER MOUNTING DETAIL 4 5/8"* (117) 90˚ DOOR OPENING TOP VIEW 341/2"* 101/4" (876) *DOOR/DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION (260) 203/8" MAXIMUM DOOR OPENING 93/4" (518) (248) 4" FRONT VIEW (102) SIDE VIEW *1/2" (13) +_ ADJUSTMENT IN LEVELING LEGS Dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information Model 700TF(I) S P E C I F I C AT I O N S Model 700TF(I) All Freezer Overall Width 27" (686) Overall Height 80" (2032) Overall Depth 24" (610) MODEL OPTIONS All Freezer All Freezer with Automatic Ice Maker 700TF Freezer Capacity 15.3 cu ft (433 L) Minimum Height (levelers in) 700TFI Door Clearance 25 1/2" (648) Drawer Clearance 19 1/2" (495) PA N E L O P T I O N S Electrical Requirements Integrated (custom panels) Plumbing Requirements 115 V AC, 60 Hz, 15 amp circuit Classic Stainless Steel Finish /S Water Supply Platinum Stainless Steel Finish /P Carbon Stainless Steel Finish /B Annual Energy Usage (based on 8.29 cents per kilowatt hour) Stainless steel door and drawer front panels are ordered and shipped as sales accessories and include tubular handles. 79 1/2" (2019) Shipping Weight Special Note 1/ 4" copper line 20–100 psi 652 kWh / $ 55 360 lbs (163 kg) Door and drawer panels and handles are available in three stainless steel finishes Specifications are subject to change without notice. ACCESSORIES Tubular handles in classic, platinum and carbon stainless steel Dual installation heater kit (TTDUAL or BBDUAL) Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Model 700TF(I) I N S TA L L AT I O N S P E C I F I C AT I O N S TOP VIEW 11/2" (38) TOP VIEW 6" ANTI-TIP BRACKET (152) 131/2" 25" (343) (635) CL 151/2" (394) 27" 9" (686) ANTI-TIP BRACKET 131/2" (343) 27" CL (686) WATER LINE SIDE ENTRY LOCATIONS (229) WATER LINE BOTTOM ENTRY LOCATION 11/2" 11/2" (38) (38) 27" 25" (686) (635) LOCATE ELECTRICAL WITHIN SHADED AREA – ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI-TIP BRACKET LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA 41/2" 80" (2032) 3" (114) (76) 1/4" (6) 13" (330) 9" (229) 21/2" (64) 3/4" (19) 151/2" (394) NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD ANTI-TIP BRACKET FRONT VIEW WATER LINE SIDE ENTRY LOCATION SIDE VIEW Dimensions may vary by ± 1/8" (3). DIMENSIONS Finished Rough Opening Width 27" (686) Finished Rough Opening Height 80" (2032) Finished Rough Opening Depth 25" (635)* Location of Electrical Within shaded area Location of Plumbing (Model 700TFI only) Within shaded area * The depth of the Model 700TF(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Model 700TF(I) I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. The depth of Model 700TF(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration. The anti-tip bracket must be installed to prevent the unit from tipping forward. Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets. Refer to the full-scale illustrations at the end of this section for specifics on panels and door openings. Door panels can grow beyond the 80" (2032) height to accommodate any size of door as long as you stay below the recommended door panel weight limit of 40 lbs (18 kg). Door panels must be a minimum of 5/8" (16) thick. The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of 5/8" (16) thick. For the bottom drawer, the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser. We recommend using D-style handles, which should be located on the opposite side from the hinge, centered on the cabinet door and the top, center area of the drawer panel. Two Integrated units may be installed next to one another. Refer to page 11 for additional information. For Integrated models with an automatic ice maker, rough in the water supply line. Connect a 1/4" OD copper line to the house supply, being sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit. Dimensions in parentheses are in millimeters unless otherwise specified. Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently. When routing the water through the side walls, you must place the water line within 1/2" (13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip bracket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration for placement of the water line. Do not route water supply line in front of the compressor tray. The tray must be slid forward for service. Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration. A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary. All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration. Do not use an extension cord or two prong adapter. Electrical ground is required. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The Integrated Installation Guide packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly. 5 Planning Information Model 700TF(I) I N T E G R AT I N G C A B I N E T RY C A B I N E T RY A P P L I C AT I O N S Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the doors and/or drawers. As you look at styles of cabinets, keep some important facts in mind: Weight Limitations – The door panel cannot exceed 40 lbs (18 kg) and each drawer panel must not exceed 12 lbs (5 kg). Panel Thickness – Door and drawer panels must be a minimum of 5/8" (16) thick. The height of the door panel can grow beyond 45 3/8" (1153) and exceed the 80" (2032) overall height as long as you stay below the recommended door panel weight limit. The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. We recommend using D-style handles. For the cabinet door, handles must be located near the edge of the panel opposite the hinge, centered top to bottom. Locate handles in the top center area of the drawer panels. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. As the reveal between cabinets and the Integrated unit decreases, the potential exists for severe finger pinching or crushing if a hand or fingers are placed in the opening when the door is closing. Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Model 700TF(I) I N T E G R AT I N G C A B I N E T RY F R A M E D C A B I N E T RY A P P L I C AT I O N S Framed cabinetry applications present you with different questions to address. The illustrations on this page show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country. Also refer to the fullscale illustrations at the end of this section for specifics on door openings. FRAMED CABINETRY SUB-ZERO UNIT CABINET FRAME CABINET DOOR 24 (610) TO WALL PANEL 1/8" (3) REVEAL IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Refer to the illustrations. 27 (686) 1 Traditional Frame – full overlay. 2 T SUB-ZERO UNIT CABINET FRAME 24 Illustrations on the following pages give dimensions for an Integrated base or tall unit installed within a framed cabinetry beaded inset application. Review the illustrations, giving particular attention to the overall panel specifications. Also refer to the full-scale illustrations at the end of this section for specifics on door openings. (610) TO WALL 1 CABINET DOOR PANEL 1/8" (3) REVEAL 27 (686) 2 Traditional Frame – standard overlay. S T SUB-ZERO UNIT 24 (610) TO WALL CABINET FRAME 1 CABINET DOOR 1/8" (3) REVEAL PANEL 2 27 (686) Traditional Frame – 3/8" (10) offset. Dimensions in parentheses are in millimeters unless otherwise specified. 7 Planning Information Model 700TF(I) F R A M E D C A B I N E T RY – B E A D E D I N S E T A P P L I C AT I O N The illustration shows an Integrated tall unit installed within a framed cabinetry beaded inset application. 24" (610) SUB-ZERO UNIT CABINET DOOR TO WALL IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly. DOOR PANEL A A TOP VIEW A) ALL REVEALS ARE 1/8" (3) B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS C) BOTTOM RAIL MUST BE REMOVABLE 27" (686) *DIMENSIONS MAY VARY 26 3/4" (679) PANEL WIDTH 11/2" (38) 47 7/8" 84" (1216) (2624) SHADED AREA INDICATES STATIONARY STYLES AND RAILS 80"* (2032) A B 13 9/16" (345) A B 341/2" (876)* 15 1/16" 11/2" (383) (38) A C 4"* 27" 11/2" (686) (38) 11/2" (38) FRONT VIEW (102) 4" (102) 24" (610) SIDE VIEW Installation of an Integrated tall unit within framed cabinetry. *Dimensions may vary. Dimensions in parentheses are in millimeters unless otherwise specified. 8 Planning Information Model 700TF(I) F R A M E L E S S C A B I N E T RY A P P L I C AT I O N S The illustration below shows a hypothetical installation of a Integrated tall unit within frameless cabinetry. Review the illustration, giving particular attention to the overall panel specifications. Also refer to the full-scale illustrations at the end of this section for specifics on door openings. IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly. FRAMELESS CABINETRY 26 3/4"* (679) 24" PANEL WIDTH (610) A 45 3/8" (1153) 80"* (2032) 79 7/8"* (2029) A 13 9/16" (345) A 341/2" (876)* 16 11/16"* (424) 4"* (102) 27" TOE KICK (686) SIDE VIEW FINISHED OPENING A) ALL REVEALS ARE 1/8" (3) *DIMENSIONS MAY VARY Installation of an Integrated tall unit within frameless cabinetry. *Dimensions may vary. Dimensions in parentheses are in millimeters unless otherwise specified. 9 Planning Information Model 700TF(I) PA N E L C O N S I D E R AT I O N S The illustrations below provide panel width dimensions for installation of a single tall unit and for installing two tall units side by side. When 5/8" (16) or thicker panels are used and a reveal less than 1/4" (6) is maintained, the door panels may cause damage to the Sub-Zero unit when the door is open at the maximum 105˚ door stop. You should use the built-in 90˚ door stop to prevent damage. IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible, but panel dimensions need to be adjusted accordingly. 27 (686) * 1 (3) min 8 REVEAL * 1 (3) min 8 REVEAL 26 43 (679) 3 4 (19) PANEL 25 87 (657) 25 (635) CABINETRY OR SIDE PANEL 24 (610) 25 (635) APPLIANCE DOOR WIDTH CABINETRY OR SIDE PANEL TO BACK OF UNIT SUB-ZERO UNIT * *SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL 54 (1372) * 1 (3) min 8 REVEAL 13 (681) 26 16 13 (681) 26 16 * 1 (3) min 8 REVEAL * 1 (3) min 8 REVEAL 3 4 (19) PANEL 25 25 C (635) CABINETRY OR SIDE PANEL 24 (610) Panel width dimensions for installation of two tall units side by side. 3 4 (19) PANEL (635) CABINETRY OR SIDE PANEL Panel width dimensions for installation of a single tall unit. DOOR DOOR SUB-ZERO UNIT SUB-ZERO UNIT TO BACK OF UNIT *SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL Dimensions in parentheses are in millimeters unless otherwise specified. 10 Planning Information Model 700TF(I) CABINETS 25 (635) I N S TA L L AT I O N O P T I O N S 27 (686) TOP VIEW 2 Installation without side panels. C The illustrations on this page show some typical installations and their dimension considerations. The depth dimension in the illustrations may vary depending on cabinet styles, treatment of countertops or other design options. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustrations. CABINETS 25 (635) 2 27 (686) MINIMUM 5/8" (16) SIDE PANELS D UA L I N S TA L L AT I O N S Installation with side panels. CABINETS 25 (635) T If two or more Integrated models are installed side by side where there is 2" (51) or less of space between the units, a heater kit is recommended— TTDUAL for two tall units installed side by side and BBDUAL for two base units or a base unit and a tall unit installed side by side. These optional components are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. 54 (1372) TOP VIEW Installation of two units side by side. C CABINETS 25 (635) 2 M 27 (686) MINIMUM 5/8" (16) SIDE PANELS Installation at end of run. Dimensions in parentheses are in millimeters unless otherwise specified. 11 Planning Information Model 700TF(I) D O O R PA N E L H E I G H T The height of the door panel can grow beyond 45 3/8" (1153) and exceed the 80" (2032) overall height, as long as you stay below the recommended door panel weight limit of 40 lbs (18 kg) for 27" (868) wide units and 53 lbs (24 kg) for the Model 736TC(I). The illustration below shows how the panel may grow and what you need to consider doing to finish the area in back of the door panel. IMPORTANT NOTE: The valance you use to finish the area behind the door panel must stay behind the front plane of the finished molding as shown in the illustration. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration. U P P E R VA L E N C E D E TA I L 25 (635) TO WALL 1 21 (38) DECORATIVE VALANCE CANNOT EXTEND BEYOND THE FRONT OF THIS PLANE DECORATIVE VALANCE 1 4 (6) REMOVABLE MOLDING BY SUB-ZERO 45 83 (1153) TO BOTTOM OF DOOR PANEL TOP HINGE 80* (2032) TO FLOOR *FINISHED HEIGHT OF 80" (2032) IS TO TOP OF SUB-ZERO MOLDING Dimensions in parentheses are in millimeters unless otherwise specified. 12 Planning Information Model 700TF(I) TOE KICK CLEARANCE The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). IMPORTANT NOTE: You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser. The illustration below shows the area below the lower drawer where the operating mechanical equipment of the Integrated unit is housed. IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration. TO E K I C K A R E A D E TA I L 9 1016 (268) PANEL 1 2 (13) 11 1616 (424) PANEL 11 9 16 (246) 10 (254) OPTIONAL BASE MOLDING MUST BE REMOVABLE 4 24 (102) (610) TO WALL 2 85 TO 4 (67) (102) Dimensions in parentheses are in millimeters unless otherwise specified. FLOOR 13 Planning Information SUB-ZERO DOOR SUB-ZERO DOOR Model 700TF(I) F U L L - S C A L E T E M P L AT E FRAMED CABINETRY IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. 24 (610) TO BACK 24 OF UNIT (610) TO BACK OF UNIT LINE OF INTERFERENCE* LINE OF INTERFERENCE* 105˚ maximum door opening – 1/4 scale (top view) LINE OF INTERFERENCE* LINE OFDOOR INTERFERENCE* AT MAXIMUM OPENING AT MAXIMUM DOOR OPENING MOUNTING BRACKET SCREW MOUNTING BRACKET SCREW 1 (3) MIN. 8 1 (3) REVEAL MIN. 8 REVEAL PANEL PANEL 3 4 (19) 3 4 (19) APPLIANCE DOOR WIDTH 25 87 (657) 25 87 (657) APPLIANCE DOOR WIDTH SUB-ZERO DOOR SUB-ZERO DOOR 24 (610) 24 (610) TO BACK BACK OF TO UNIT OF UNIT LINE OF INTERFERENCE* LINE OF INTERFERENCE* SIDE MOLDING AND SIDE MOLDING AND INSTALLATION HARDWARE INSTALLATION HARDWARE PROVIDED BY SUB-ZERO PROVIDED BY SUB-ZERO FLUSH FLUSH FURNITURE FURNITURE FINISH FINISH Door closed – full scale (top view) Dimensions in parentheses are in millimeters unless otherwise specified. *If the panel is thicker than 3/4" (19), it is recommended that you utilize the built-in 90˚ door stop to prevent damage to the panel and face frame. 14 Planning Information SUB-ZERO DOOR SUB-ZERO DOOR 3/4" (19) DOOR PANEL Model 700TF(I) 3/4" (19) DOOR PANEL COUNTERTOP SIDE PANEL F U L L - S C A L E T E M P L AT E COUNTERTOP SIDE PANEL FRAMELESS CABINETRY IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. 24 (610) TO WALL 24 (610) TO WALL LINE OF INTERFERENCE* LINE OF INTERFERENCE* 105˚ maximum door opening – 1/4 scale (top view) Adjacent side panel and countertop application 1 (3) MIN. 8 1 (3) REVEAL MIN. 8 LINE OF INTERFERENCE* LINE OFDOOR INTERFERENCE* AT MAXIMUM OPENING AT MAXIMUM DOOR OPENING REVEAL MOUNTING BRACKET SCREW MOUNTING BRACKET SCREW 3 4 (19) 3 4 (19) PANEL PANEL 25 87 (657) APPLIANCE DOOR WIDTH 25 87 (657) APPLIANCE DOOR WIDTH SUB-ZERO DOOR SUB-ZERO DOOR 24 (610) 24 (610) TO BACK OF TO UNIT BACK OF UNIT LINE OF INTERFERENCE* LINE OF INTERFERENCE* SIDE MOLDING AND SIDE MOLDING AND INSTALLATION HARDWARE INSTALLATION HARDWARE PROVIDED BY SUB-ZERO PROVIDED BY SUB-ZERO Door closed – full scale (top view) Dimensions in parentheses are in millimeters unless otherwise specified. *If the panel is thicker than 3/4" (19), it is recommended that you utilize the built-in 90˚ door stop to prevent damage to the panel and face frame. 15