Download Enterasys ssr-gsx31-04 Expansion Module

Transcript
DECLARATION OF CONFORMITY
NOTICE
Enterasys Networks and its licensors reserve the right to make changes in specifications and other
information contained in this document without prior notice. The reader should in all cases consult
Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER
(INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS
MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS
AND ITS LICENSORS HAVE BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE
POSSIBILITY OF SUCH DAMAGES.
Enterasys Networks, Inc.
35 Industrial Way
Rochester, NH 03866-5005
Application of Council Directive(s):
Manufacturer’s Name:
Manufacturer’s Address:
European Representative Name:
European Representative Address:
Conformance to Directive(s)/
Product Standards:
 2001 by Enterasys Networks, Inc.
All Rights Reserved
Printed in the United States of America
Equipment Type/Environment:
Order Number: 9033748-02 October 2001
X-Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors. All
other product names mentioned in this manual may be trademarks or registered trademarks of their
respective companies.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté
par le ministère des Communications du Canada.
VCCI NOTICE
This is a class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 55024
EN 60950
EN 60825
Networking Equipment, for use in a
Commercial or Light Industrial Environment.
Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above
directives.
SSR-GLX39-04 & SSR-GSX31-04
Table 3
The SSR-GLX39-04 and SSR-GSX31-04 are 4-port, T-Series Gigabit Line Cards for the XP-8000 and
XP-8600 switch routers. The SSR-GLX39-04 connects to 1000Base-LX fiber and the SSR-GSX31-04
connects to 1000Base-SX fiber.
SPECIFICATIONS
Ports
Transmit Power
Minimum
-17 dBm
Minimum
-9.5 dBm
Maximum
0 dBm
Maximum
-4 dBm
1000Base-LX Fiber
Network Interfaces
Receiver Sensitivity
SC connector—850 nm Short-Wavelength Transceiver
SC connector—1300 nm Long-Wavelength Transceiver
50/125 µm Multimode Fiber-Optic Cables
62.5/125 µm Multimode Fiber-Optic Cables
10/125 µm Singlemode Fiber-Optic Cables
Minimum
-20 dBm
Minimum
-11.5 dBm
Maximum
-3 dBm
Maximum
-3 dBm
Transmit Power
LEDs
Number of Flows/Routes
Table 5
Layer-2 Entries = 512,000 (memory size = 32 MB)
Layer-3 Entries = 256,000 (memory size= 16 MB)
Switch Method
LED Indicators
LED
Condition
Status
Offline
On
The line card is offline (powered off) and ready to hotswap.
This LED also lights briefly whey you reboot or reset the XP but
turns off as soon as the control module discovers the
SSR-GLX39-04 or SSR-GSX31-04.
Online
On
The SSR-GLX39-04 or SSR-GSX31-04 is ready to receive,
process, and send packets (if configured).
Per-Port Link
Green
Indicates that the port hardware detected the cable plugged into
the port and a good link is established.
Intermittent
Red
The port received an error during operation.
Red
The port hardware detected a cable plugged into the port, but a
bad link was established.
Queue Buffer
Packet memory size: 8MB
Safety
Physical Dimensions
Meets the requirements of UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950,
73/23/EEC, and EN 60825.
Size: 3.94 cm H x 19.68 W x 27.94 D (1.55 in. H x 7.75 W x 11 D)
Weight: 1.4 kg (3.0 lbs)
Electromagnetic Compatibility
Power Consumption
Compliant with the requirements of FCC Part 15, CSA C108.8, EN 55022, VCCI V-3, EN 55024, 89/
336/EEC, and EN 500082-1.
BTU/hr = 273.63
AC Volt Amps = 81
NOTE: If your system uses a redundant power configuration or only
one power supply, you will not be able to support more than 4 cards in
the XP-8000 and 10 in the XP-8600.
Temperature
Off
No link from the port exists.
Per-port Rx
Green
The port’s transceiver is receiving packets.
Orange
The port’s transceiver is receiving flow-control packets.
Per-port Tx
Green
The port’s transceiver is transmitting packets.
Orange
The port’s transceiver is transmitting flow-control packets.
Per-port AN
Green
The line card auto-negotiated the operating mode of the link
between full-duplex and half-duplex.
Intermittent
Orange
Auto-negotiation is in progress.
Operating: 41° to 104° F (5° to 40° C)
Storage: -22° to 164° F (-30° to 73° C)
Humidity
15% to 90% (non-condensing)
CONNECTIVITY GUIDELINES
Table 1 1000Base-SX Multi-Mode Fiber Specifications
Fiber Diameter
Modal Bandwidth
Range
Connector
62.5/125 µm
160 MHz/km
2-220 m (7-722 ft)
SC
Table 2
CLASS A ITE NOTICE
1000Base-SX Fiber
Receiver Sensitivity
Table 4
4 1000Base-SX or 1000Base-LX SC connectors
50/125 µm
WARNING: This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
OPTICS
Address-based and Flow-based.
AGENCY STANDARDS
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment uses,
generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause interference in which case the user will be required to correct the
interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
89/336/EEC
73/23/EEC
Enterasys Networks, Inc.
35 Industrial Way
PO Box 5005
Rochester, NH 03867
Mr. Jim Sims
Enterasys Networks Ltd.
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England
200 MHz/km
2-275 m (7-902 ft)
400 MHz/km
2-500 m (7-1641 ft)
SC
500 MHz/km
2-550 m (7-1805 ft)
SC
Orange
Indicates a problem with auto-negotiation configuration.
Red
An auto-negotiation failure occurred.This fault may occur if the
link partner does not support full-duplex operation.
Off
Auto-negotiation is disabled or the link is down.
SC
1000Base-LX Single-Mode Fiber Specifications
Fiber Diameter
Modal Bandwidth
Range
Connector
62.5/125 µm
160 MHz/km
2-220 m (7-722 ft)
SC
200 MHz/km
2-275 m (7-902 ft)
SC
50/125 µm
10/125 µm SMF
400 MHz/km
2-500 m (7-1641 ft)
SC
500 MHz/km
2-550 m (7-1805 ft)
SC
N/A
2-5000 m (7 ft-3.1 m)
SC
1
2
INSTALLING THE MODULE
ELECTRICAL HAZARD: Only qualified personnel should perform
installation procedures.
NOTE: You may install the SSR-GLX39-04 or SSR-GSX31-04 in any
line card slot except the CM slot which supports a control module
only.
The connector pins are assigned as follows:
Table 6
CAUTION: The SSR-GLX39-04 and SSR-GSX31-04 are easily
damaged by electrostatic discharge.
To prevent electrostatic damage, observe the following guidelines:
Do not remove the module from its packaging until you are ready to
install it.
Do not touch any of the module’s pins, connectors or components.
Hold the module only by its edges or front panel.
Wear an anti-static wristband connected to a suitable earth ground whenever handling
the module.
Store or transport this module only in appropriate anti-static packaging.
•
•
•
•
•
Pin
Connection
Rx
When mated with the cable connector, the SC connector is keyed to run the proper Tx
to Rx and Rx to Tx fibers.
Hotswap
You may install this module into a live system without powering off the device. However,
you may not remove an active module from a live system except under the following
conditions:
•
Press the Hotswap button. The Online LED will turn off and the Offline LED will
turn on.
•
After unpacking SSR-GLX39-04 or SSR-GSX31-04, check the contents of the box to be
sure you received the following items:
One SSR-GLX39-04 or SSR-GSX31-04 module in anti-static bag
One disposable anti-static wristband
•
•
1.
Tools
Enter the following from the CLI and click enter: Enable -> System -> Hotswap ->
Out -> Slot -> #. The Online LED will turn off and the Offline LED will turn on.
2.
CAUTION: You may install the SSR-GLX39-04 or SSR-GSX31-04 in
the chassis with the chassis powered up. However, before removing
an existing line card, hotswap the line card as described previously.
This installation requires the following tools:
If a cover plate is installed in the line module slot, remove the cover plate: loosen the
captive screws on each side of the coverplate and pull out the plate.
Align the backsheet of the line card between the card guides as shown in Figure 1.
NOTE: Make sure that the circuit card is between the card guides.
Check both tracks.
Phillips screwdriver
3.
4.
5.
Slide the line card all the way into the slot, firmly but gently pressing the line card
fully in place to ensure that the pins on the back of the line card are completely seated
in the backplane.
Tighten captive screws. Align the captive screws with the holes in the face of the
module and tighten the screws to secure the SSR-GLX39-04 or SSR-GSX31-04 to the
chassis.
Repeat the above steps for additional cards.
Preliminary Setup
Figure 1 Install the Module
Firmware Image Requirements
Version 8.3.0.0 or later.
CLI Setup
Enter the following commands at the CLI before implementing any configurations.
1. Type the following from Enable mode to enter Configuration mode
Enable -> Configure #
2. You may now begin configuring ports on the SSR-GLX39-04 or SSR-GSX31-04.
Refer to the Enterasys X-Pedition Command Line Interface Reference Manual for
details.
•
•
•
•
•
Offline LED turns on and remains on until card is online.
Port LEDs turn on momentarily and the CLI indicates that the system discovered the
line card in proper slot.
CLI indicates all ports are initialized and offline LED turns off.
Online LED lights.
Link LED is active for connected lines.
Common Errors
•
•
•
The line card is not inserted properly or seated completely in the chassis
Connectors for the connected lines are not seated properly.
Attached device is not configured to match configuration mode of module (i.e., autonegotiation, speed, duplex).
Helpful CLI Commands for Debugging
OR...
Instructions
Equipment Checklist
Anti-static wristband
Proper Boot Sequence
Rx/Tx Pin Assignments
Tx
Handling the Module
TROUBLESHOOTING
Connector Pin Assignments
Card Guides
Circuit Card
OFFLINE
ONLINE
T
T
T
T
R
R
R
R
L
L
L
L
A
A
A
SSR-CM2
Console
A
CONTROL MODULE
10/100 Mgmt
Metal Plate
•
•
•
•
System show hardware
System show version
Port show port status gi.x.y (where x is the chassis slot that contains the line card and
y is a specific port number on the card).
System show bootlog
For additional information about installing this module or to learn more about what
capabilities are included in the firmware release you are using, visit the Enterasys
Networks web site.
T
To view the current mode for a particular port, enter the following (where x is the chassis
slot that contains the line card and y is a specific port number on the card):
XP# port show port status gi.x.y
3
R
OFFLINE
L
ONLINE
A
4
Web Site: http://www.enterasys.com/
Getting Help
For additional support related to the Common CLI syntax or this document, contact
Enterasys Networks using one of the following methods:
World Wide Web
http://www.enterasys.com/
Phone
(603) 332-9400
Internet mail
[email protected]
FTP
Login
Password
ftp://ftp.enterasys.com
anonymous
your email address
To acquire the latest image for
this product and any available
release notes
http://www.enterasys.com/download
Additional documentation
http://www.enterasys.com/support/manuals
To send comments or suggestions concerning this document, contact the
Technical Writing Department via the following email address:
[email protected]
Please include the document Part Number in the email message.
•
•
•
•
•
•
The default mode for each port on the XP-8000 and XP-8600 is:
Full duplex/ 1000 mbs/ autonegotiation on
Quick Start
ADDITIONAL INFORMATION
Before contacting Enterasys Networks for technical support, have
the following information ready:
Default Module Settings
SSR-GLX39-04
SSR-GSX31-04
Your Enterasys Networks service contract number
A description of the failure
A description of any action(s) taken to resolve the problem (e.g., changing mode
switches, rebooting the unit)
The serial and revision numbers of all involved Enterasys Networks products in the
network
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of trouble (if known)
5
9033748-02