Download AirStage ARXC36L Specifications
Transcript
Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE Series The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. OUTDOOR UNITS Various Line-up for each buildings 4HP 5HP 6HP AJ*A36LALH AJ*A45LALH AJ*A54LALH AJ* : AJY (FUJITSU), AJH (GENERAL) Building owners Installers End users Service and Management companies Wide lineup of indoor units and controllers to support a variety of properties. INDOOR UNITS 02 Compact Cassette Cassette Compact Duct Slim Duct (Drain Pump internal) Low Static Pressure Duct / Duct High Static Pressure Duct Floor / Ceiling Ceiling Compact Wall Mounted (EEV internal / EEV external) Wall Mounted Small Office Large Homes CONTROLLERS Central Controller Central Remote Controller Individual Controller Group Remote Controller Touch Panel Controller System Controller (Software) Wireless Remote Controller Simple Remote Controller Wired Remote Controller 03 FEATURES Efficiency in actual operation The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load Load curve (a typical office building) Building load (%) 100 80 60 40 20 0 0 3 6 9 12 15 18 21 24 Time (h) High EER / COP 4.53 High part load performance (6HP class) 4.20 4.00 3.60 3.95 3.45 66 % UP 4 HP : EER 5 HP : COP 6 HP 50% 5.73 100% 3.45 EER Cooling part load 04 46 % UP 50% 5.75 100% 3.95 COP Heating part load Conditions : Connected indoor units: AUXA30LALH+AUXD24LALH Cooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB Heating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB Large propeller fan DC inverter control High performance and low noise realized by large propeller and optimization of angle. Efficiency is improved by mounting of new active filter module. DC fan motor Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted. Subcool heat exchanger Pressure Cooling performance is improved by mounting of dual tube heat exchanger. effect Large heat exchanger Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. Optimized refrigerant flow design Highly accurate parts Enthalpy DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. High Compressor efficiency High efficiency compressor motor Cooling performance improved DC Twin Rotary compressor Compressor capacity High 05 FEATURES Operation Performance is Efficiently Controlled. Room temperature set point limitation Economy operation The minimum and maximum temperature range can be set. The temperature setting is offset automatically over a certain period of time. Heating (°C) Cooling 30 Set Temp. Down Heating Set Temperature MAX. - 4°C 28 Down Down Down Economy operation Control Temperature 26 Economy operation 24 Set Temp. 22 Economy operation Economy operation Control Temperature 20 18 MAX. +2°C Cooling Set Temperature 16 Up Up 14 12 10 Original Set Temp. Set point limitation setting Capacity save operation The power consumption at peak is cut down. Setting range 80% Capacity Capacity save Setting level 60% 40% 0% Central Remote Controller Time Wasteful Operation is Prevented. Auto Off function This prevents waste of energy. OFF OFF OFF 18:00 06 20:00 22:00 Heating capacity (kW) Powerful Heating Heating capacity is improved at low outdoor temperature by our advanced technology. J-II series (6HP) 16.6 33% Current model (6HP class) UP ! -20 -10 0 7 Outdoor temperature (°C) Low Noise Design Low noise design of outdoor unit Low noise mode Significantly reduced noise by optimized airflow structure design of outdoor unit. Outdoor unit can be switched to silent mode, depending on the installation environment. Current model 56dB J-II series (4~ 6HP) 53dB Noise level Rated noise value -5dB ~ -6dB Low noise mode 6HP class (Cooling) Time Various Comfort Control Function Easy auto changeover function Non-stop oil recovery operation Auto louver grill (Option for Slim Duct) At the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature. The product continues to operate without stopping the cooling or heating operation during oil recovery modes. Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet Temp. (°C) Cooling operation Heating operation With Auto Louver Set Temp. J-II series 35 ON 30 Operation stopped at oil recovery Heating operation Function setting is required. 1 indoor unit (Master) can apply this function. Current model Time ON 25 20 OFF Temperature(°C) 40 15 Time 07 FEATURES Central Control of Small Office, Shop, etc. Building Management System A/C central controller Convertor for BMS Control Network Convertor for LONWORKS ® UTY-VLGX Network Convertor UTY-VGGX BACnet ® Gateway (Software) Group Remote Controller UTY-CGG* UTY-ABGX Max. controllable 18 indoor units Lighting facilities Ventilation system Central Remote Controller Security system UTY-DCG* Max. controllable 100 indoor units Touch Panel Controller UTY-DTG* Max. controllable 400 indoor units System Controller (Software) UTY-APGX Max. controllable 1,600 indoor units G*: GY (FUJITSU), GG (GENERAL) Control system composition example VRF network system Building control computer Central Remote Controller or Network Convertor for LONWORKS ® System Controller (Software) BACnet ® Gateway (Software) 08 Touch Panel Controller Network Convertor Group Remote Controller Individual and Central Control of Large Homes Central Remote Controller Wireless Remote Controller Wired Remote Controller UTY-LNH* UTY-RNK* UTY-DCG* • Automatic display of number of connected indoor unit • Max. controllable 100 units or Group Remote Controller UTY-CGG* Simple Remote Controller • Max. controllable 18 indoor units UTY-RSK* UTY-RHK* With operation mode Without operation mode K*: KY (FUJITSU), KYT (FUJITSU), KG (GENERAL) H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL) Control system composition example Central Remote Controller or Wired Remote Controller Group Remote Controller Wired Remote Controller + Simple Remote Controller Simple Remote Controller IR Receiver Unit + Wireless Remote Controller Wireless Remote Controller Wired Remote Controller + Wireless Remote Controller 09 FEATURES Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Actual piping length Height difference between outdoor 120 m max. and indoor units Piping length from first separation tube to the farthest indoor unit Height difference between indoor and indoor units 30 m max. 15 m max. 40 m max. Total piping length 180 m max. High Capacity Connection Number of connectable indoor unit 4 HP 2 to 6 units Indoor unit 5HP 2 to 8 units 6 HP 2 to 9 units Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Cooling : -5°C~46°C Heating : -20°C~21°C 12 types, 52 models (°C) 50 40 Heating 21°C 30 20 10 -20°C area Operation possible in heating. 0 -10 -20 10 Cooling 46°C -5°C -20°C Connectable indoor unit capacity range 130 % max. Easier Installation Easy piping connection Flexible installation of outdoor unit Improvement of the reliability by decreasing the flare connection. Corresponds to the outdoor unit concentration installation. Flare connection J-II series Previous model EV kit Terminal box Power supply cable Flare connection Reduced installation intervals by front access Power supply (Indoor ) Power supply (Outdoor ) Easy wiring connection • Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires) Flexible installation by 4 way pipe direction • Improvement of wiring installation by common with V-II power supply method. Convenient Commissioning Support Automatic address setting function Connection check function The address of each indoor unit can be automatically set by button switch of outdoor unit. Possible to confirm whether wiring connection and address setting are correct by check run function for a short time. 3 7 1 0 2 4 5 6 • Display connected indoor unit numbers • Duplicately set address number of indoor unit can be displayed Press the push button of outdoor unit. Easy to connect with V-II communication system J-II system V-II system Connects without a converter It is possible to connect directly with the transmission cable of the V-II system without convertor. 11 FEATURES Design for Easy Maintenance Easy to read 7-segment LED Confirm detail operational and trouble status without using specific equipment Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen. Wired Remote Controller Faulty unit number (Remote controller address) Error code 7-segment LED SU MO TU WE TH FR SA Simple Remote Controller Remote controller address Error code Movable PCB panel Easier for maintenance work behind the PCB Emergency Stop Function Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped. Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped. Central Remote Controller or Emergency stop function Touch T hP Panell Controller Trouble diagnosis by Service Tool Emergency stop function Emergency stop function Transmission cable (Non-polar 2 wires) Connection to Service Tool • Detail operation status and recent error history can be checked and analyzed by using Service Tool. Service Tool UTY-ASGX • Last 5 min. operation memory can be also recorded. USB adaptor (Field supplied) Equipment Detail (Diagram) 12 Software OUTDOOR UNITS Specifications AJ*A36LALH Model name Capacity range HP Maximum connectable indoor unit AJ*A45LALH AJ*A54LALH 4 5 6 6 8 9 Power source 1Ø, ~ 230 V, 50 Hz 11.2 14.0 Heating 12.5 16.0 18.0 Cooling 2.80 3.89 4.49 4.56 Cooling Capacity Input power kW kW 15.5 Heating 2.76 3.81 EER Cooling 4.00 3.60 3.45 COP Heating 4.53 4.20 3.95 6,200 6,400 6,900 50 51 53 52 53 55 Air flow rate W/W m 3/h High Cooling Sound pressure level dB(A) Heating Heat exchanger fin Blue fin mm Dimensions (H×W×D) Weight kg Refrigerant charge kg Liquid Connection pipe diameter 1,334 x 970 x 370 117 4.8 5.3 9.52 mm Gas 15.88 Cooling Operation range 19.05 -5 to 46 °CDB Heating -20 to 21 Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function might work when using it outside the operation range. AJ* : AJY (FUJITSU), AJH (GENERAL) Dimensions 166 650 154 AJ*A36LALH / AJ*A45LALH / AJ*A54LALH 32 (410) 40 51(Gas) 370 43(Liquid) (Unit : mm) 36 970 32 370 12 Terminal blocks (Transmission) 907 3-Way valve (Liquid) 1000 1334 Terminal blocks (Power) 21 Ø28 (Cable port) Ø28 (Cable port) Pipe port 55 A Detail 21 65 Ø28 (Cable port) Ø28 (Cable port) Pipe port A 50 14 15 50 142 155 120 50 25 95 50 le port) 131 87 21 Ø28 (Cab Pipe port 65 227 341 305 89 279 ((Liquid valve)) 297 (Gas valve) le port) ab Ø28 (C 70 111 3-Way valve (Gas) 50 438 Pipe & cable port 13 622 AJ* : AJY (FUJITSU), AJH (GENERAL) INDOOR UNIT Indoor Unit Lineup 12 Types, 52 Models, Capacity range from 2.2kW to 14.0kW Capacity range (kW) Model code 2.2 2.8 3.6 4.5 7 9 12 14 AUXB07LALH AUXB09LALH AUXB12LALH AUXB14LALH ARXB07LALH ARXB09LALH ARXB12LALH ARXB14LALH ARXD07LATH ARXD09LATH ARXD12LATH ARXD14LATH AB*A12LBTH AB*A14LBTH AS*A09LACH AS*A12LACH AS*A14LACH AS*E09LACH AS*E12LACH AS*E14LACH Compact Cassette Cassette Compact Duct Slim Duct (Drain pump internal) Low Static Pressure Duct Duct High Static Pressure Duct Floor / Ceiling Ceiling Compact Wall Mounted (EEV internal) AS*A07LACH Compact Wall Mounted (EEV external) AS*E07LACH With this model, connection of EV kit is necessary Wall Mounted * : Y(FUJITSU), H(GENERAL) 14 Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs. 5.6 7.1 9.0 11.2 12.5 14.0 18 24 30 36 45 54 AUXB18LALH AUXB24LALH AUXD18LALH AUXD24LALH AUXA30LALH AUXA36LALH AUXA45LALH AUXA54LALH ARXB24LATH ARXB30LATH ARXB36LATH ARXB45LATH ARXA24LATH ARXA30LATH ARXA36LATH ARXA45LATH ARXC36LATH ARXC45LATH AB*A36LBTH AB*A45LBTH ARXB18LALH ARXD18LATH AB*A18LBTH ARXD24LATH AB*A24LBTH AB*A30LBTH AS*A18LACH AS*A24LACH AB*A54LBTH AS*A30LACH 15 INDOOR UNIT Compact Cassette AUXB07LALH AUXB14LALH AUXB09LALH AUXB18LALH AUXB12LALH AUXB24LALH Grille is an option Powerful wide air flow & Quiet operation High efficiency 2-stage turbo fan 2-stage turbo fan Previous turbo fan 1-stage A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. + 2-stage 2 stage Heat exchange efficiency: 20 %UP Wind velocity Fast Slow Quiet quality High lift drain pump Optimization of wing form (laminar wing type) and wing number (7 blades each) Ceiling panel Height 700mm Designed by CFD-analysis (fluid) simulations Quiet Laminar wing Airflow runs through smoothly along the laminar wing No airflow separation Quiet Optional parts Adoption of laminar wing Spin direction Air Outlet Shutter Plate: UTR-YDZB Fresh Air Intake Kit: UTZ-VXAA Insulation Kit For High Humidity: UTZ-KXGC Airflow direction Specifications AUXB07LALH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Med Sound pressure level m3/h 2.2 2.8 3.6 4.5 5.6 7.1 2.8 3.2 4.1 5.0 6.3 8.0 25 25 29 35 36 84 540 550 600 680 710 1,030 450 530 590 580 830 350 350 390 390 400 450 High 34 35 37 38 41 50 30 30 34 34 35 44 25 25 27 27 27 30 Med dB(A) mm kg Weight Liquid (Flare) Gas (Frare) mm mm kg Note : Specifications are based on the following conditions. 16 15 17 ø6.35 ø9.52 ø12.70 ø15.88 UTG-UFYC-W (FUJITSU brand); UTG-UFGC-W (GENERAL brand) Model name Dimensions (H x W x D) 245 x 570 x 570 ø25 (I.D) ; ø32 (O.D.) Drain Weight AUXB24LALH 450 Dimensions (H x W x D) Grille (option) AUXB18LALH 1Ø, 230V ~, 50Hz Low Low Connection pipe diameter AUXB14LALH AUXB12LALH AUXB09LALH V/ø/Hz 50 x 700 x 700 2.6 Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Cassette AUXD18LALH AUXA36LALH AUXD24LALH AUXA45LALH AUXA30LALH AUXA54LALH Grille is an option Powerful, wide airflow and quiet operation High efficiency turbo fan with 3-dimensional blade High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling. 450mm 500mm Previous blade 3-dimensional blade Heat exchanger < Motor side > Heat exchanger Separation phenomenon of airflow causes noise < Motor side > Wind velocity Fast Quiet No airflow separation Uneven airflow Slow : Spin direction : Airflow direction : Turbulent flow noise Improvement of the airflow distribution The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Front part Optional parts Ceiling Bottom view Rear part Much less temperature irregularity happens by spreading airflow widely Round louvre IR Receiver Kit : Air Outlet Shutter Plate : Panel Spacer : Insulation Kit for High Humidity : Wide Panel : Fresh Air Intake Kit : UTY-LRH*B1 UTR-YDZC UTG-BGYA-W UTZ-KXGA / UTZ-KXGB UTG-AGYA-W UTZ-VXGA H* : HY(FUJITSU), HG(GENERAL) Specifications AUXD18LALH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Med Sound pressure level AUXD24LALH m3/h AUXA54LALH 5.6 7.1 9.0 11.2 12.5 14.0 6.3 8.0 10.0 12.5 14.0 16.0 39 46 59 80 99 119 1,150 1,280 1,600 1,800 1,900 2,000 1,040 1,300 1,300 1,370 1,370 870 870 1,100 1,100 1,100 1,100 High 36 38 40 44 46 47 30 33 38 38 39 39 29 29 33 33 33 33 Med Weight dB(A) mm 246 x 840 x 840 kg 23 288 x 840 x 840 27 Liquid (Flare) Gas (Frare) ø9.52 mm UTG-UGYA-W (FUJITSU brand); UTG-UGGA-W (GENERAL brand) Model name Dimensions (H x W x D) ø19.05 ø15.88 ø25 (I.D.) ; ø32 (O.D.) Drain Weight AUXA45LALH 940 Dimensions (H x W x D) Grille (option) AUXA36LALH 1Ø, 230V ~, 50Hz Low Low Connection pipe diameter AUXA30LALH V/ø/Hz mm kg Note : Specifications are based on the following conditions. 50 x 950 x 950 5.5 Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 17 INDOOR UNIT Compact Duct ARXB07LALH ARXB14LALH ARXB09LALH ARXB18LALH ARXB12LALH Small and compact indoor unit suitable for many applications Low noise level Low static pressure mode Model 7 Static pressure range Pa Noise level (Low speed) dB(A) 9 12 14 18 30 30 0 to 50 24 27 25 Normal mode Airflow drop prevention Airflow A low noise level has been achieved for each capacity Low noise realized Static pressure (Pa) Compact design Flexible installation Ultra-slim duct air conditioner for easy installation Floor concealed Ceiling concealed Height 217mm Slim size (217mm) allows installation even where the space behind the ceiling is narrow. Air-intake Optional parts Bottom side Back side Air-intake at back side makes it possible to reduce the noise effectively. Remote Sensor Unit : UTD-RS100 IR Receiver Unit : UTB-*WC Drain Pump Unit : UTZ-PX1BBA *WC : YWC, TWC Specifications ARXB07LALH Model No. Power source Cooling Capacity Heating Input power kW W High Med Air flow rate m3/h Low Static pressure range Pa Standard static pressure High Sound pressure level ARXB09LALH *1 Med dB(A) Low Dimensions (H x W x D) Weight Gas (Frare) ARXB18LALH 2.2 2.8 3.6 4.5 5.6 2.8 3.2 4.0 5.0 6.3 46 55 63 90 96 370 440 590 800 890 310 370 500 750 810 280 340 450 700 730 0 to 50 0 to 50 0 to 50 0 to 50 0 to 50 25 25 25 25 25 29 31 30 33 36 26 29 28 32 34 24 27 25 30 30 mm 217 x 663 x 595 kg 18 mm Drain 18 ARXB14LALH 1Ø, 230V ~, 50Hz Liquid (Flare) Connection pipe diameter ARXB12LALH V/ø/Hz Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 217 x 953 x 595 25 ø6.35 ø9.52 ø12.70 ø15.88 ø25 (I.D.) ; ø32 (O.D.) *1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table. Slim Duct ARXD07LATH ARXD14LATH ARXD09LATH ARXD18LATH ARXD12LATH ARXD24LATH •Slim design with drain pump •Increase static pressure range Slim design Auto Louver Grille Kit (Option) This model is slim design, it can install at the place where a ceiling is narrow. Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Auto Louver Grille Drain port Slim Duct Height 198mm Drain pump built-in Drain pump Air-intake Wired Remote Controller Air intake direction can be selected to match the installation site. Wireles Remote Controller Flexible installation Back side Bottom side Floor concealed Ceiling concealed Depending on the installation site, air-intake at back side makes it possible to reduce the noise effectively. Selectable wide range static pressure Static pressure range 0 to 90 Pa 24 model is 0 to 50Pa External Static Pressure[Pa] By using DC fan motor, it is possible to change the static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller. 120 Available air flow rate range @ Hi speed (ARXD12LATH) 60 0 400 Optional parts IR Receiver Unit: Remote Sensor Unit: Auto Louver Grille Kit Normal 11 steps 500 600 Air Flow [m3/h] 700 UTB-*WC UTD-RS100 UTD-GXSA-W (for ARXD07/09/12/14LATH) UTD-GXSB-W (for ARXD18LATH) UTD-GXSC-W (for ARXD24LATH) 800 *WC : YWC, TWC Specifications ARXD07LATH Model No. Power source Cooling Capacity Heating Input power kW W High Med Air flow rate m3/h Low Static pressure range Pa Standard static pressure High Sound pressure level *1 Med dB(A) Low kg Weight Liquid (Flare) Connection pipe diameter Gas (Frare) ARXD24LATH 7.1 2.2 2.8 3.6 4.5 5.6 2.8 3.2 4.0 5.0 6.3 8.0 44 50 54 92 83 122 550 600 600 800 940 1,330 490 550 510 710 840 1,240 440 480 450 610 750 1,100 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50 25 25 25 25 25 25 28 29 30 34 34 35 25 26 27 32 32 32 22 24 24 28 28 29 198 x 900 x 620 198 x 1,100 x 620 198 x 700 x 620 18 19 ø15.88 ø12.70 Drain Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 27 23 ø9.52 ø6.35 mm ARXD18LATH 1Ø, 230V ~, 50Hz mm Dimensions (H x W x D) ARXD14LATH ARXD12LATH ARXD09LATH V/ø/Hz ø25 (I.D.) ; ø32 (O.D.) *1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table. 19 INDOOR UNIT Low Static Pressure Duct/Duct Low Static Pressure Duct Duct ARXB24LATH ARXA24LATH ARXB30LATH ARXA30LATH ARXB36LATH ARXA36LATH ARXB45LATH ARXA45LATH Airflow Line-up of low-noise and high-power models, compatible with a wide range of static pressure Two-direction drain piping Duct type Duct indoor unit Two-direction drain piping Low Static Pressure Duct type 0 Static pressure Easy maintenance See below for the case of rear suction type Low Static Pressure Duct type New model Previous model Optimum model for hotels or bedrooms 1 1 3 4 4 An ultra low-noise model that achieves a quiet interior. Perfect for hotels or bedrooms with limited air duct installation space. Two different levels can be selected according to the static pressure range. 29dB 1.Control box 2.Fan casing 3.Fan 4.Motor 3 2 2 Bottom panel: 2 pieces ARXB30 Low Large bottom panel: 1 piece Duct type Powerful model with a flexible design Optional parts With a powerful motor, appropriate for a wide range of static pressure. Flexible air duct installation is possible in a large space such as an office. Max. Remote Sensor Unit : UTD-RS100 Long-Life Filter : UTD-LF25NA Flange (Square) : UTD-SF045T 150Pa Flange (Round) : UTD-RF204 IR Receiver Unit : UTB-*WC Drain Pump Unit : UTZ-PX1NBA *WC : YWC, TWC Specifications ARXB24LATH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Med m3/h Low Static pressure range Pa Standard static pressure High Sound pressure level ARXB30LATH V/ø/Hz Med dB(A) Low kg Weight Gas (Frare) ARXA30LATH ARXA36LATH ARXA45LATH 1Ø, 230V ~, 50Hz 9.0 11.2 12.5 7.1 9.0 11.2 12.5 10.0 12.5 14.0 8.0 10.0 12.5 14.0 145 198 253 338 190 188 312 312 1,100 1,410 1,710 1,970 1,280 1,280 1,720 1,720 920 1,280 1,600 1,790 1,210 1,210 1,670 1,670 810 1,150 1,470 1,670 1,130 1,130 1,600 1,600 0 to 80 0 to 80 0 to 80 0 to 80 30 to 150 30 to 150 30 to 150 30 to 150 40 50 50 60 100 100 100 100 31 34 37 41 38 40 43 43 27 32 35 38 36 38 41 41 25 29 33 36 34 36 39 39 270 x 1,135 x 700 270 x 1,135 x 700 45 43 45 43 ø9.52 ø9.52 mm Drain Note : Specifications are based on the following conditions. 20 ARXA24LATH 8.0 Liquid (Flare) Connection pipe diameter ARXB45LATH 7.1 mm Dimensions (H x W x D) ARXB36LATH 1Ø, 230V ~, 50Hz ø15.88 ø19.05 ø25 (I.D.) ; ø32 (O.D.) ø15.88 ø19.05 ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. High Static Pressure Duct ARXC36LATH ARXC45LATH These indoor units allow for high airflow quantities Low noise design Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan. Easy installation (Compact size & Lightweight) A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. Volume Weight 47.5% 40% down down (unit: mm) 1,050 New model (ARXC36L) Previous model 500mm 400 400 ARXC36L : 45kg 800mm Metal fan ø240mm Previous model : 75kg Heat exchanger 400mm Heat exchanger 800 400mm Plastic fan ø225mm 1,250 500 Casing (Metal Sheet) Casing (Plastic) Previous model: Metal fan [53.1dB(A)] New model: Plastic fan [45dB(A)] (At 100Pa : Actual noise measurement value) 45dB(A) ARXC36L Optional parts Long-Life Filter : UTD-LF60KA IR Receiver Unit : UTB-*WC Remote Sensor Unit : UTD-RS100 *WC : YWC, TWC Specifications ARXC36LATH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Med m3/h Low Static pressure range Pa Standard static pressure High Sound pressure level Med dB(A) 12.5 14.0 405 427 2,600 3,500 1,950 3,000 1,450 2,460 100 to 200 100 to 250 100 100 45 49 38 45 mm kg Weight Liquid (Flare) Connection pipe diameter 11.2 12.5 Gas (Frare) 42 32 Low Dimensions (H x W x D) ARXC45LATH 1Ø, 230V ~, 50Hz V/ø/Hz 400 x 1,050 x 500 45 47 ø9.52 (Flare) mm Drain Note : Specifications are based on the following conditions. ø19.05 (Flare) ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 21 INDOOR UNIT Floor / Ceiling Type AB*A12LBTH AB*A14LBTH AB*A18LBTH AB*A24LBTH The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs Flexible installation Easy maintenance Example for floor installation Example for ceiling installation Floor console Under ceiling Double auto swing High power DC fan motor A combination of up/down and right/left directional swing allows three-dimensional air direction control. • High power • Wide rotation range • High efficiency RIGHT and LEFT SWING UP and DOWN SWING 3 2 1 4 1 5 2 Compact design 3 4 Symmetrical, slim and compact design. 5 steps selectable 655 4 steps selectable 990 199 (Unit : mm) Specifications AB*A12LBTH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Sound pressure level Med m3/h AB*A24LBTH 3.6 4.5 5.6 7.1 4.0 5.0 6.3 8.0 30 42 74 99 660 780 1,000 1,000 570 640 720 820 490 550 580 680 High 36 40 46 47 32 36 39 42 28 34 35 37 Med dB(A) mm Dimensions (H x W x D) kg Weight Liquid (Flare) Gas (Frare) mm Drain AB* : ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. 22 AB*A18LBTH 1Ø, 230V ~, 50Hz Low Low Connection pipe diameter AB*A14LBTH V/ø/Hz 199 x 990 x 655 27 25 ø6.35 ø9.52 ø12.70 ø15.88 ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. Ceiling Type AB*A30LBTH AB*A36LBTH AB*A45LBTH AB*A54LBTH Easily concealed in any installation Installation Open Concealed Wall mounted (Field Supplied) General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. Double auto swing and wide airflow Condensate lift-up mechanism (Option) Auto airflow direction and auto swing Optional drain lift-up mechanism allows flexible installation. Right and left Max. 500mm Fresh air intake Up and down 5 steps selectable Indoor 1 2 Optional parts 3 4 4 steps selectable Drain Pump Unit : UTR-DPB24T Flange : UTD-RF204 Specifications AB*A30LBTH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Sound pressure level Med m3/h AB*A45LBTH AB*A54LBTH 1Ø, 230V ~, 50Hz 9.0 11.2 12.5 14.0 10.0 12.5 14.0 16.0 66 85 131 180 1,630 1,690 2,010 2,270 1,370 1,400 1,600 1,780 Low 1,140 1,170 1,230 1,280 High 42 45 48 51 38 38 42 45 33 34 35 36 Med dB(A) Low mm Dimensions (H x W x D) kg Weight 240 x 1,660 x 700 Gas (Frare) 48 47 Liquid (Flare) Connection pipe diameter AB*A36LBTH V/ø/Hz ø9.52 mm Drain AB* : ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. ø19.05 ø15.88 ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 23 INDOOR UNIT Compact Wall Mounted Type EEV internal EEV external AS*A07LACH AS*E07LACH AS*A09LACH AS*E09LACH AS*A12LACH AS*E12LACH AS*A14LACH AS*E14LACH Simple design with energy saving. Compact design Air conditioner filter features Long-life* ion deodorization filter New model The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. 790mm *The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty. 275mm Apple-catechin filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. 215mm Easy maintenance More Comfort & Convenience • Powerful cooling & heating by using DC fan motor • Auto-restart function memorizes the operating mode as before, once the power supply is restored. • Comfortable timer (ON, OFF, PROGRAM, SLEEP) Removable & washable panel Specifications AS*A07LACH Model No. Power source V/ø/Hz Cooling Capacity Heating Input power kW W High Air flow rate Sound pressure level Med m3/h AS*A14LACH AS*E07LACH AS*E09LACH AS*E12LACH AS*E14LACH 1Ø, 230V ~, 50Hz 2.2 2.8 3.6 4.5 2.2 2.8 3.6 4.5 2.8 3.2 4.1 5.0 2.8 3.2 4.1 5.0 16 16 19 30 15 16 20 28 490 500 560 670 490 500 560 680 450 450 480 490 450 450 480 490 370 370 420 420 370 370 420 420 High 35 36 39 44 34 35 38 43 33 33 35 37 32 32 34 35 27 27 31 32 26 26 30 30 Med dB(A) mm Dimensions (H x W x D) kg Weight Liquid (Flare) Gas (Frare) mm Drain EV Kit (option) AS* : ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. 24 AS*A12LACH 1Ø, 230V ~, 50Hz Low Low Connection pipe diameter AS*A09LACH 275 x 790 x 215 275 x 790 x 215 9 9 ø6.35 ø6.35 ø12.70 ø12.70 ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) - UTR-EV09XB Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. UTR-EV14XB Wall Mounted Type AS*A18LACH AS*A24LACH AS*A30LACH Simple & Elegant Appearance Design “Vertical airflow” provides powerful floor level heating Air conditioner filter features Vertical airflow (m) 2.1 Ion Deodorization Filter (24/30) (24/30) Organic coating fin used heat exchanger 1 0 Apple-catechin Filter 0 3 6 9 12(m) (˚C) 46 Outside air conditions: 2°C 60% Operation contents: Heating Set temperature (Max set temp) 30°C, Air flow Hi Vertical flap: Downward Horizontal flap: Center o Power diffuser (full open) 33 32 31 30 Pre Filter 29 Antibacterial deodorizing pre-filter with special ceramic powder “Horizontal airflow” does not blow cool air directly at the occupants in the room Long-life* Ion Deodorization Filter Horizontal airflow (m) 2.1 (24/30) (24/30) 1 The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) 0 Power diffuser 0 3 6 Outside air conditions: 35°C 40% Operation contents: Cooling Set temperature (Min set temp) 18°C, Air flow Hi Vertical flap: Upward Horizontal flap: Center 9 15 16 Using different filters at both sides 12(m) (˚C) 17 Easy maintenance Simplification of drain pan cleaning improves maintenance-ability. 18 Apple-catechin Filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. Specifications AS*A18LACH Model No. Power source Cooling Capacity Heating Input power kW W High Air flow rate Sound pressure level Med m3/h AS*A30LACH 5.6 7.1 8.0 6.3 8.0 9.0 35 64 91 840 1,100 1,240 770 910 980 Low 690 730 770 High 41 48 52 39 43 45 35 35 35 Med dB(A) Low mm Dimensions (H x W x D) kg Weight Liquid (Flare) Connection pipe diameter AS*A24LACH 1Ø, 230V ~, 50Hz V/ø/Hz Gas (Frare) 320 x 998 x 228 15 ø9.52 mm Drain AS* : ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. ø15.88 ø12 (I.D.) ; ø16 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 25 CONTROLLER Control Systems System diagram The V-II system supports every users needs by offering a variety of Control systems, including individual control, central control and building management control options. Building Management Air Conditioning Central Control System Controller (Software) UTY-APGX Air Conditioning Individual Control Wired Remote Controller UTY-RNK* System Outdoor unit USB Adaptor *2 Indoor unit (Field supplied) Internet or Public Telephone Line Simple Remote Controller UTY-RSK* Remote/Monitoring side Touch Panel Controller UTY-DTG* Signal Amplifier UTY-VSGX Simple Remote Controller UTY-RHK* Without master control Central Remote Controller UTY-DCG* IR Receiver Unit UTB-YWC General-purpose Building Control Computer Wireless Remote Controller UTY-LNH* Group Remote Controller UTY-CGG* Network Convertor Connectable to various sized BMS/BAS*1 IR Receiver Kit UTY-LRH*B1 UTY-VGGX BACnet ® Gateway (Software) UTY-ABGX USB Adaptor *2 (Field supplied) or Network Convertor (BMS / LONWORKS® ) UTY-VLGX External Switch Controller UTY-TEKX Card-key For single split (Field supplied) Web Monitoring Tool (Software) UTY-AMGX Service Tool (Software) UTY-ASGX USB Adaptor*2 Internet or Public Telephone Line (VRF system side) Network Convertor UTY-VGGX (Field supplied) USB Adaptor*2 (Field supplied) * : Y(FUJITSU), G(GENERAL) (Monitoring side) *1. BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation. The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway) 26 Transmission line (VRF Network) LONWORKS ® Network Remote controller line Ethernet USB cable Signal line(Single split system) Group Remote Controller line Comparison table of Controllers Item Model name Max. controllable remote controller groups Wired Remote Simple Remote Simple Remote*1 Wireless Remote Group Remote Central Remote Controller Controller Controller Controller Controller Controller Touch Panel System Controller Software Controller UTY-RHK* UTY-RSK* UTY-RHK* UTY-LNH* UTY-CGG* UTY-DCG* UTY-DTG* UTY-APGX 1 1 1 1 8 100 400 1600 *2 *2 *2 *2 *2 Max. controllable indoor units 9 9 9 9 18 100 400 1600 Max. controllable groups - - - - - 16 400 1600 - Air conditioning control function On / Off - Operation mode setting Fan speed setting Room temp. setting Room temp. set point limitation - Display - - - - - - - - - Right/left air direction flap setting - - - - Group setting - - - - - - RC prohibition - - - - - - Anti freeze setting - - - - - - - - - - Failure - Defrosting - Current time - - Day of week - - - - - R.C. prohibition Cooling/heating priority - Address display - Schedule timer Timer - Up/down air direction flap setting Economy mode setting - - - Week - - - On/off per day 4 - - - 4 20 20 72 On/off per week 28 - - - 28 140 140 504 Period Week Week Year Year - - - - - - Sleep timer - - - - - - - Program timer - - - - - - - 10 10 On/off timer - - - - 2 Min. unit of timer setting (Minutes) 30 - - 5 10 10 Status monitoring system - - - - - - - - - - - - - - - Day off Electricity charge calculation Control - Test operation Error history - *3 *3 Emergency stop - - - - - - Control via internet - - - - - - - E-mail notification for malfunction - - - - - - - - K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL) *1 "Operation mode" setting is not available for this model. *2 In the case of connection constitution for only J-II. *3 This function is available only through external input. control. 27 CONTROLLER Wired Remote Controller Max. controllable 9 UTY-RNK* indoor units The room temperature can be controlled by detecting the temperature accurately from the built-in sensor •Simple operation with Built-in Weekly / Daily Timer. •Control up to 9 indoor units. •Up to 2 wired remote controllers can be connected to a single indoor unit. Accurate and comfortable Built-in timers Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements. Weekly timer: Possible to set ON/OFF time to operate twice each day of the week. Setback timer: Possible to set temperature for two times spans and for each day of the week. At "Weekly timer" + "Set back timer" setup Example of changing sensor Indoor unit Remote Sensor in the bedroom Diagnosis check function Day Wired Remote Controller in the living room Two methods are available for determining the cause of failure in the event of a malfunction occurs: Night Wired remote controller Remote sensor The detecting point can be easily changed Simple installation Displayed temperature is set temperature. Components are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed. Simple Remote Controller Max. controllable 9 UTY-RSK* indoor units UTY-RHK* (Without ability to change operation mode) Compact remote controller provides access to basic functions UTY-RSK* •Up to 9 indoor units can be controlled with one remote controller. •Suitable for hotels or offices as it is easily operated with no complex functions. User-friendly operation UTY-RHK* Without ability to change operation mode Functions •A large On / Off button is provided in the centre of the remote controller for easy operation. •Background light enables easy operation in a darkened room. •Following an error display, diagnostics can be carried out on the controller. UTY-RSK* Model UTY-RHK* On / Off Fan control Operation mode *1 Room temp. setting *1: "Operation mode" setting is not available. It is recommend to use together with other type controller. Specifications Model No. Power Source Dimensions (H x W x D) (mm) Weight (g) DC12V is supplied by the indoor unit. K*: KY(FUJITSU), KYT(FUJITSU), KG(GENERAL) 28 UTY-RNK* UTY-RSK* DC 12V DC 12V UTY-RHK* DC 12V 120 x 120 x 18 120 x 75 x 14 120 x 75 x 14 160 90 (100 : UTY-RSKYT) 90 (100 : UTY-RHKYT) Wireless Remote Controller Max. controllable 9 UTY-LNH* indoor units Selectable Simple and sophisticated operations with a choice of 4 daily timers 4 daily timers •A single controller controls up to 9 indoor units. UTY-LNH* Built-in timers System addressing Select from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours. During installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting. Transmission line Indoor unit Wireless Remote Controller Outdoor unit Easy operation setting Code selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.) Wide and precise IR Receiver Unit UTB-*WC Duct type indoor unit Necessary to control for all duct type by Wireless Remote Controller IR Receiver Unit *WC : YWC, TWC Wireless Remote Controller IR Receiver Kit UTY-LRH*B1 Cassette type indoor unit can be controlled with Wireless Remote Controller Wireless Remote Controller IR Receiver Kit Specifications Model No. Battery or Power source Dimensions (H x W x D) (mm) Weight (g) UTY-LNH* UTB-*WC 1.5V (R03 / LR03 / AAA) x 2 DC 12V UTY-LRH*B1 DC 12V 158 x 56 x 20 122 x 60 x 26.5 213.8 x 213.8x 25.7 70 150 140 DC12V is supplied by the indoor unit. H*: HY(FUJITSU), HG(GENERAL) 29 CONTROLLER Group Remote Controller Max. controllable UTY-CGG* group R.C. in a VRF network system 64 Max. controllable 8 Group control of indoor units with simple operation remote controller groups •Up to 8 remote controller groups can be controlled by one Group Remote Controller. •Up to 64 Group Remote Controllers can be connected in one VRF network system. Control up to 8 remote controller groups •Single Group Remote Controller controls and monitors up to 8 remote controller groups. Hotel floor Network Convertor Guest room Group Remote Controller 1 Hotel 2 Simple Remote Controller Office floor Office & Lounge Office room Meeting room Office room Wireless Remote Controller Restaurant Wired Remote Controller Wireless Remote Controller Wired Remote Controller Restaurant Wired Remote Controller Group Remote Controller 1 : To control office floor and hotel floor (8 remote controller groups). Group Remote Controller 2 : To control hotel floor (5 remote controller groups). Lobby •Network Convertor is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers) Network Convertor UTY-VGGX High performance and compact size Built-in weekly timers ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually. The weekly timer is provided as a standard function. 1. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. Allows separate settings for each day of the week. Central control ON/OFF control Weekly timer Specifications Model No. Power Source Dimensions (H x W x D) (mm) Weight (g) DC12V is supplied by a network converter. G*: GY(FUJITSU), GG(GENERAL) 30 Lobby UTY-CGG* DC 12V 120 x 120 x 18 200 Central Remote Controller Max. controllable 100 UTY-DCG* Indoor units Max. controllable Central control of small- and medium-sized buildings and tenants. 16 groups • Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • Automatic display switching for the number of connected units • Operation guidance display • Automatic switching of function menu • Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish. System overview • It allows multiple indoor units grouping (Max.16 groups controlled) • Interlock with external device Group : Hallway Group : 3F Group : Division A Group : Division B Group : Division C Group : Tenant B Group : Tenant C Group : 2F Group : Tenant A Emergency stop function • External input / output contact • Detachable power supply unit Functions Diverse control of indoor units • Individual control • Remote controller prohibition (All, On/Off,Mode, Temp.,Timer,Filter) • Room temperature set point upper and lower limitation Weekly timer Set temp. Weekday Automatic clock adjustment 28°C 26°C Weekend Holiday 28°C 26°C 26°C 26°C 28°C 28°C 8:00 12:00 13:00 18:00 21:00 Time Setting pattern 1 Easy Installation Setting pattern 2 Ceiling SW BOX • The control panel and power supply unit can be installed separately. • For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Power supply unit Power supply unit Control panel Control panel Wall Wall Control panel + Power supply unit Specifications UTY-DCG* Model No. Power Source Dimensions (H x W x D) (mm) Weight (g) Control Panel Power Supply Unit DC 5 V 100-240V, 50-60Hz, Single phase 120 x 162 x 26 99 x 135 x 40 308 355 PACKING LIST Packing List Control Panel / Power Supply Unit / Connecting cable, etc. G*: GY(FUJITSU), GG(GENERAL) 31 CONTROLLER Touch Panel Controller Max. controllable 400 UTY-DTG* indoor units •Large-sized 7.5-inch TFT color •LCD Easy finger touch operation •Stylish shape and design to suit all application •No additional component is required for installation •Up to 400 indoor units can be controlled •Selectable 2 display types (Icon / List) in monitoring mode •Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish. Real size screen image Easy operation Versatility • Large and wide-angled LCD is easily viewable even at a distance • Easy-to-understand icon-driven Graphical User Interface (GUI) • Wide range of simple-to-understand icons CSV format data edited by PC can be imported to Touch Panel Controller. Data transfer available by USB • Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon • Up-to-date status display • Background color identifies current control operation Blue for monitoring, green for operational control • Flat touch screen is easily cleaned • Non-glare coating on touch panel controller minimizes fingerprint marking 32 System overview Up to 400 indoor units can be controlled Group A Group B It allows multiple indoor unit grouping Emergency stop control Air conditioner can be turned off through the external input control Emergency stop function Functions • Up to 400 indoor units can be controlled • It allows multiple indoor units grouping • Schedule timer function is standard (20 patterns per day) • Emergency stop function(through the external input control) • Temperature upper and lower limit setting • The clock of each indoor unit correct setting Individual control Flexible grouping Schedule control Indoor units operation monitoring Automatic clock adjustment The time setting of each controller can be set in batch automatically. Easy installation & maintenance Switch box Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed. Mounted plate • Correctable mechanism for tilting (horizontal) after the installation of the body No additional component is required for installation • There is no need for the installation space of power supply adaptor and transmission adaptor etc. Easy-to-remove front cover Specifications Model No. Power Source Dimensions (H x W x D) (mm) Weight (g) Interface UTY-DTG* 100-240V 50/60Hz 260 x 246 x 54 2,150 USB 2.0 G*: GY(FUJITSU), GG(GENERAL) 33 CONTROLLER System Controller Software Max. controllable 4 UTY-APGX VRF network systems Max. controllable System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. 400 outdoor units Max. controllable 1,600 • Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled. indoor units • Supports VRF S series, V series, V-ll series and J-II series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met. • Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish) Remote centralized control System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site. Remote central control 1 VRF Explorer can control or monitor up to 10 sites. VRF Explorer Building management company, management center, etc. VRF Controller A maximum of 10 locations, such as offices or factories VRF Controller On site central control Internet or Telephone Line or LAN Max. 4 VRF network systems per site Internet or Telephone Line or LAN 1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously). VRF Explorer Building Management VRF Explorer Company A (In charge of Central Monitoring Screen for all Properties the day shift) VRF Explorer VRF Explorer Building Management Company B (In charge of the night shift) Internet or Telephone Line or LAN VRF Explorer Office Management Center VRF Controller VRF Explorer Security Company Headquarters Management Center Special Property Detailed Monitoring Screen User friendly view and operation Monitoring located site Main operation monitoring screen Monitor mode (Site) Monitor mode (Building) 34 Operation monitoring of each site Management functions Monitor mode (Floor) Schedule setting Monitor mode (List) Functions Energy saving management Option UTY-PEGX:software Peak cut operation Outdoor unit capacity save Indoor unit rotation operation Controls overall operation while maintaining comfort according to the overall power consumption target value. Sets an upper limit of outdoor unit capacity and performs capacity save operation at peak times. Reduces annual power consumption by operating indoor units in rotation. Outdoor unit stop range Forced thermostat off range Target power consumption Indoor unit rotation screen Power consumption Outdoor unit capacity control screen Ideal control line (Use of Shows change in power average power consumption) consumption by time Outdoor unit capacity upper limit Time Electricity charge apportionment Others Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant. When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option) •Batched stop •Divers control of indoor units •Oprating & control record •Schedule control •Error display & E-mail nitification •Prohibition setting Billing management for users for a set period of time, such as for hotels System Controller CT Option Signal transmission line 1Ø, 2wire 230V, 50Hz DPM Room 301 Room 302 Room 303 Room 201 Room 202 Room 203 Room 101 Room 102 Room 103 Outdoor unit 1Ø, 2wire 230V, 50Hz Specifications UTY-APGX Model No. Personal Computer AT compatible machine that runs Microsoft® Windows® Operating System Microsoft® Windows® XP Professional (Service Pack 3 or later / English version), Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*), Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*) *English, Chinese, French, German, Spanish, Russian, Polish CPU Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher HDD 40 GB or more of free space (5 GB for VRF Explorer PC) Memory 2 GB or more (VRF Controller), 1 GB or more (VRF Explorer) Interface USB port is required for each of the followings for Server PC ; • Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet. Accelerator Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0 Other Software Required Adobe® Reader® 9.0 or later PACKING LIST Wibe Key Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included. CD-ROM Software protection key to be inserted in a USB slot running System Controller. System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key. Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R 35 CONVERTOR & ADAPTOR Network Convertor UTY-VGGX •This network convertor is to be used for connecting single split system or group remote controller with the VRF network system. •Please select the function by switching the dip switch during the installation. Installation example •Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. •Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc. •A single network convertor can be used to connect and control up to 16 single units. Network Convertor Group of Single Split USB adaptor VRF network system Single Split System Controller Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models. Big Multi Used for connecting Group Remote Controller 4 group remort controllers can be connected to a single Network convertor. Network Convertor Group Remote Controller * 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors, Central remote controller and Touch panel controllercan be connected in one VRF network system. VRF network system Specifications Model No. Power Source Power Consumption (W) Dimensions (H X W X D) (mm) Weight (g) 36 UTY-VGGX 50-60Hz 220-240V 8.5 67 x 288 x 211 1,500 Model No. Power Source Power Consumption (W) Dimensions (H X W X D) (mm) Weight (g) UTY-VLGX 220-240V 50/60Hz 4.5 67 x 288 x 211 1,500 Network Convertor for LONWORKS ® Max. controllable Max. controllable 4 128 Units to BMS UTY-VLGX indoor units •For connection between VRF network system and a LONWORKS ® open network for management of small to medium-sized BMS and VRF network system. •The unit permits central monitoring and control of a VRF network system from a BMS through a LONWORKS ® interface. •Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS ® Installation example General-purpose building control computer (LONWORKS® device) Max. 4 Network Convertor Transmission specifications (BMS side) Max. 100 Max. 128 indoor units outdoor units Transmission speed 78kbps Transceiver FT-X1 (Echelon® Corporation) Transmission way form Lighting facilities Network Convertor Security system Free topology None (It attaches at the terminal of a network.) Terminal resistor VRF network system 1 Max. 100 Max. 128 indoor units outdoor units Automatic fire alarm interface Ventilation system LONWORKS® Network BACnet ® Gateway VRF network system 2 Software UTY-ABGX Max. controllable Max. controllable 4 400 VRF network systems Max. controllable outdoor units 1,600 indoor units •The VRF network system can be incorporated into a Building Management System. •Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks. •Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC) BACnet® / IP over Ethernet. •Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway. •Supports VRF S/V series, V-II series and J-II series Installation example BACnet VRF network system 1 CD-ROM (Software) Software Protection Key ® The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests. BACnet ® Operator Workstation (B-OWS) USB adaptor*1 (Field supplied) Indoor unit Outdoor unit Lighting facilities VRF network system 2 Security system USB adaptor (Field supplied) ® BACnet Gateway Indoor unit Outdoor unit Max. 4 VRF network systems (UTY-ABGX) USB adaptor (Field supplied) USB adaptor (Field supplied) CD-ROM Software (Software) Protection Key Automatic fire alarm interface Ventilation system = BACnet® Gateway for each system. = USB cable = Transmission line (VRF Network) = Ethernet *1: USB adaptor is U10 USB Network Interface of Echelon® Corporation. Specifications UTY-ABGX Model No. Personal Computer AT compatible machine that runs Microsoft® Windows® Operating System Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*) Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*) Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*) *English, Chinese, French, German, Spanish, Russian, Polish •64-bit version of Windows® are not supported. CPU Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher HDD 40 GB or more of free space Memory 2 GB or more Interface USB port (x 2-5) is required Ethernet port is required Other Software Required Adobe® Reader® 9.0 or later PACKING LIST Packing List CD-ROM / Wibu Key Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R 37 CONVERTOR & ADAPTOR Signal Amplifier UTY-VSGX •Transmission Line length can be extended up to 3,600m for with multiple Signal Amplifiers. •Up to 8 signal amplifiers can be installed in a VRF network system. •A signal amplifier is required, (1) When the total wiring length of the transnission line exceeds 500m. (2) When the total number of units on the transnission line exceeds 64. Installation example B C A E Signal Amplifier External Switch Controller UTY-TEKX Air conditioner switching can be controlled by connecting other sensor switches •In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms. •Card-key or other sensor switches are available as a field supplied parts. Electrical wiring Auto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode. Room temp. Installation example T2 Indoor Unit Heating Time T1 = ON, T2 = OFF Note 1. Please choose a thermosensor switch which can be set up for T1 and T2. SU MO TU WE TH FR SA 7 3 6 9 12 15 18 21 Sensor SW (Field supplied) To individual dry contact Card-key Cooling T1 External Switch Controller (UTY-TEKX) Note 2. The remote controller's operation is prior to the auto mode operation. 1 2 3 E COM SW1 SW2 Remote Controller Line External input Card-key (Field supplied) External Switch Controller Sensor SW Indoor Unit 1 2 3 E COM SW1 SW2 Remote Controller Line External input Sensor SW (Field supplied) External Switch Controller Specifications Model No. Power Source Power Consumption (W) Dimensions (H X W X D) (mm) Weight (g) 38 UTY-VSGX 220-240V 50/60Hz 4.5 67 x 288 x 211 1,500 Model No. Power Source Dimensions (H X W X D) (mm) Weight (g) DC12V is supplied by the indoor unit. UTY-TEKX DC 12V 120 x 75 x 30 90 SERVICE & MONITORING Service Tool Software Max. Monitor and controll Max. Monitor and controll indoor units outdoor units 400 UTY-ASGX 100 Extensive monitoring and analysis functions for installation and maintenance •Operation status can be checked and analyzed to detect even the smallest abnormalities •Storage of data on system operation status on a PC allows access even from off site. •Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels •This software can be connected to any point of transmission line with USB adaptor (field supplied). •Supports VRF S/V series, V-II series and J-II series. Wiring connection (Field supplied) Functions USB adaptor (Field supplied) •Equipment Detail (Diagram) Transmission line Refrigerant piping •Equipment Detail (List) •Operation History •Error History •Remote File Download •System List •Commissioning Tool •Network Topology Analyzer Indoor unit Indoor unit Web Monitoring Tool •Remote setting •System Time Setting •Central Release •Model Name Writer •Error Memory Reader •Time Guard Information •Software Version acquire and display Software VRF network system can be supported 4 1,600 UTY-AMGX Product features indoor units •Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks. can be supported •Error notification can be automatically transmitted to several locations using the internet*1. •Requires either a dedicated internet connection or public telephone line. •Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location. •The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool. •Monitoring side computer is not required to install special software, requires only general web browser. •Supports VRF S/V series , V-II series and J-II series. *1: Use of internet mail system required. Web Monitoring System Support 4 VRF network systems USB adaptors Monitoring Side Internet or Public Telephone Line USB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units. Suitable for large-scale buildings or hotels. VRF Network System Side Outdoor unit Transmission line Web Monitoring Tool USB adapter (Field supplied) Indoor unit VRF Network System 1 VRF Network System 2 VRF Network System 3 VRF Network System 4 Max. 400 Indoor unit Max. 400 Indoor unit Max. 400 Indoor unit Max. 400 Indoor unit Specifications Model No. UTY-ASGX Operating System Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium, Business Edition (English version), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version) Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher CPU 10 GB or more of free space HDD Memory UTY-AMGX AT compatible machine that runs Microsoft® Windows® Personal Computer 1 GB (Vista, 7), 512 MB (XP) or more 40 GB or more of free space 1 GB or more USB port for U10 USB Network Interface and Software protection key. Interface USB port (for U10 USB Network Interface Max.4, Software protection key) Following interface is required for remote connection: Public Telephone LIne : Modem is required Internet using LAN : Ethernet port is required Software Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later Hardware CD-ROM drive PACKING LIST Packing List CD-ROM / Wibu Key Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R 39 OTHERS VRF System Design 1. Quick model selection and design tool "Design Simulator" for VRF Fujitsu General offers software which quickly performs model selection and creates material for model estimation in the VRF initial design stage. "Design Simulator" has functions which automatically select the proper model for the required capacity, automatically draft piping diagrams and wiring diagrams, and also automatically calculate the additional refrigerant charge amount, automatically generates the reports necessary for estimation. Operation is also easily performed by drag & drop and full-fledged model design estimates can be quickly made. Features • Automatic model selection of indoor unit and outdoor unit • Simple drag & drop operation • Automatic generation of piping diagrams and wiring diagrams • Automatic calculation of additional refrigerant charge amount • Auto CAD Data (DXF), Revit Mep Data (RFA) export • Automatic report generation (Word, Excel) • Multi-language capability Design Simulator for FUJITSU VRF 2. 2D (DXF), 3D (RFA) contents data Two kinds of model data, DXF data and RFA data, necessary in detailed design are offered. These data can be procured from the Fujitsu General web site and Design Simulator RFA data 40 FGL Web site Optional Parts Controllers Wired Remote Controller Simple Remote Controller Simple Remote Controller UTY-RNK* UTY-RSK* UTY-RHK* With operation mode Without operation mode Wireless Remote Controller IR Receiver Unit IR Receiver Kit UTY-LNH* UTB-YWC UTB-TWC UTY-LRH*B1 For All Duct type For Cassette type Group Remote Controller Central Remote Controller Touch Panel Controller UTY-CGG* UTY-DCG* UTY-DTG* System Controller Software UTY-APGX K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL) Convertors / Adaptors Network Convertor Network Convertor BACnet ® Gateway UTY-VGGX for LONWORKS® UTY-VLGX UTY-ABGX CD-ROM (Software) Signal Amplifier External Switch Controller UTY-VSGX UTY-TEKX Software Software Protection Key 41 OTHERS Optional Parts Connection Tube Separation Tube Header Header UTR-BP090X UTR-H0906L UTR-H0908L Gas Pipe Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe Liquid Pipe Header 3-6 Branches UTR-H0906L 3-8 Branches UTR-H0908L Model name Others Indoor unit type Item Round Compact Duct Slim Duct - - Flange Square Remote Sensor Unit Long-Life Filter Auto Louver Grille Kit Drain Pump Unit Wide Panel - Duct UTD-RF204 UTD-RF204 UTD-RS100 - - UTD-GXSA-W UTD-GXSB-W UTD-GXSC-W UTD-SF045T UTD-SF045T UTD-RS100 UTD-RS100 UTD-RS100 UTD-LF25NA UTD-LF25NA UTD-LF60KA - - UTZ-PX1NBA UTZ-PX1NBA - Air Outlet Shutter Plate - Panel Spacer - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UTR-DPB24T - UTG-AGYA-W UTG-AGYA-W UTR-YDZC UTR-YDZC UTG-BGYA-W UTG-BGYA-W UTG-UFYC-W UTG-UFGC-W UTG-UGYA-W UTG-UGGA-W UTG-UGYA-W UTG-UGGA-W UTZ-KXGC UTZ-KXGB UTZ-KXGA UTZ-VXAA UTZ-VXGA UTZ-VXGA - - - - - - - - - - Fresh Air Intake Kit - EV Kit - - - - Insulation Kit for High Humidity - - - - - - Wall Mounted - - - - Compact Wall Mounted - - - - Ceiling - - - Floor / Ceiling - UTR-YDZB - Cassette - - Grill Kit - Slim Cassette UTD-RF204 - UTZ-PX1BBA High Static Compact Duct Cassette - - UTD-RS100 - Low Static Duct - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UTR-EV09XB UTR-EV14XB 42 Flange (Round) Flange (Square) Remote Sensor Unit UTD-RF204 UTD-SF045T UTD-RS100 For Low Static Pressure Duct type / Duct type / Ceiling type For Low Static Pressure Duct type / Duct type For All Duct type New amenity space can be offered by installing the Remote sensor. Long-Life Filter Long-Life Filter Auto Louver Grille Kit UTD-LF25NA UTD-LF60KA For Low Static Pressure Duct type / Duct type For High Static Pressure Duct type UTD-GXSA-W (for ARXD07/09/12/14LATH) UTD-GXSB-W (for ARXD18LATH) UTD-GXSC-W (for ARXD24LATH) For Slim Duct type Drain Pump Unit Drain Pump Unit Wide Panel UTZ-PX1BBA UTR-DPB24T UTG-AGYA-W For Compact Duct type For Ceiling type For Cassette type UTZ-PX1NBA Indoor unit 950 For Low Static Pressure Duct type / Duct type Panel 600 600 Air Outlet Shutter Plate Air Outlet Shutter Plate Panel Spacer UTR-YDZB UTR-YDZC UTG-BGYA-W For Compact Cassette type For Cassette type For Cassette type Shuts the air outlet when only using as 3 blow out. Shuts the air outlet when only using as 3 blow out. (mm) 50mm Panel spacer Grille Kit Grille Kit Insulation Kit for High Humidity UTG-UFYC-W UTG-UFGC-W UTG-UGYA-W UTG-UGGA-W UTZ-KXGA For Cassette type UTZ-KXGB For Slim Cassette type UTZ-KXGC For Compact Cassette type Insulation Kit For Compact Cassette type For Cassette type Fresh Air Intake Kit Fresh Air Intake Kit EV Kit UTZ-VXAA UTZ-VXGA UTR-EV09XB (for AS*E07/09LACH) UTR-EV14XB (for AS*E12/14LACH) For Compact Cassette type For Cassette type For Compact Wall Mounted type (EEV external type) 43 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co., Ltd. ISO 9001 Certified number : 01 100 79269 ISO 14001 Certified number : 272043 Fujitsu General (Shanghai) Co., Ltd. ISO 9001 Certified number : 00608Q11061R2M ISO 14001 Certified number : 00609E20454R2M Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. “ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan, the U.S.A. and other countries or areas. *Echelon ®, LONWORKS ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE). The colors may be different from the actual colors because this catalog is printed matter. Product specifications are subject to change without notice. Distributed by : Copyright© 2011 Fujitsu General Limited. All rights reserved. 6NNJ22-1201E