Download Moxa Technologies NPort 5110 Series Specifications

Transcript
Serial Device Servers
Product Selection Guides
Combo Switch / Serial Device Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2
General-purpose Device Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-3
Industrial-grade Device Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-7
Embedded Device Servers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-8
General-purpose Device Servers
Introduction to Serial Device Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9
Case Study: Power Generation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Case Study: Automatic Meter Reading
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15
NPort® S8000 Series Combo switch / serial device server. . . . . . . . . . . . . . . . . . . . . . . 8-16
NPort® 5100 Series 1-port RS-232/422/485 serial device servers . . . . . . . . . . . . . . . . 8-20
NPort® DE-211/311 1-port RS-232/422/485 serial device servers . . . . . . . . . . . . . . . . 8-23
NPort® 5200 Series 2-port RS-232/422/485 serial device servers . . . . . . . . . . . . . . . . 8-25
NPort® 5400 Series 4-port RS-232/422/485 serial device servers . . . . . . . . . . . . . . . . 8-29
NPort® 5600 Rackmount Series 8/16-port RS-232/422/485 serial device servers . . . 8-32
NPort® 5600 Desktop Series 8-port RS-232/422/485 serial device servers . . . . . . . . . 8-35
Device Servers for Industrial Automation
NPort® IA5000 Series 1 and 2-port serial device servers for industrial automation . . . 8-38
Embedded Device Servers
MiiNePort E1 Series 10/100 Mbps embedded serial device servers . . . . . . . . . . . . . . . . 8-42
NE-4100 Series 10/100 Mbps embedded serial device servers. . . . . . . . . . . . . . . . . . . . 8-45
WE-2100T Series Wireless LAN embedded serial device servers . . . . . . . . . . . . . . . . . . 8-49
8
Serial Device
Servers
Serial-to-Ethernet Solutions
Combo Switch / Serial Device Server
NPort S8000: Ethernet Switch Specifications
NPort S8000: Device Server Specifications
Ethernet Interface
Standards
8
Network Protocols
Serial Device Servers > Product Selection Guides
MIB
Flow Control
Serial Interface
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100Base FX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
ICMP, IP, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP,
IGMPv1/v2 device, GVRP, SNMPv1/v2c/v3, DHCP Server/
Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP,
GMRP, LACP, RMON
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB,
Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
IEEE 802.3x flow control, back pressure flow control interface
Optical Fiber Interface
Type
Distance
Min. TX Output
Max. TX Output
Sensitivity
Multi-mode
0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
-20 dBm
-14 dBm
-34 to -30 dBm
4
64
Data Bits
Stop Bits
Parity
Flow Control
Baudrate
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
Operation Modes
Management
IP Routing
4 RS-232/422/485 ports
3 RJ45 copper ports, 2 multi-mode fiber ports
1 (8-pin RJ45 connector)
PWR1, PWR2, READY, MASTER, COUPLER, LINK4, LINK5
Alert Tools
Automatic Reboot
Trigger
Physical Characteristics
Metal
995 g
73.1 x 134 x 105 mm
Environmental Limits
Operating Temperature
Operating Humidity
Storage Temperature
0 to 60°C
5 to 95% RH
-40 to 85°C
Power Requirements
Input Voltage
Power Consumption
12 to 48 VDC
935mA @ 12 V, 470 mA @ 24 V
Regulatory Approvals
EMC
Safety
EMS
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
UL-508, UL (UL60950-1), LVD (EN60950-1)
IEC 61000-4-2, Level 4 (ESD)
IEC 61000-4-4, Level 4 (EFT)
IEC 61000-4-5 for serial port, Level 1 (Surge)
IEC 61000-4-5 for Power Line, Level 3 (Surge)
IEC 61000-4-5 for LAN port, Level 2 (Surge)
Reliability
Buzzer, RTC, WDT
Warranty
8-2
55 Ω, 120 Ω
Dedicated RS-232 console port (8-pin RJ45)
5, 6, 7, 8
1, 1.5, 2
None, Even, Odd, Space, Mark
RTS/CTS and XON/XOFF
50 bps to 921.6 Kbps
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Tx+, Tx-, Rx+, Rx-, GND
Tx+, Tx-, Rx+, Rx-, GND
Data+, Data-, GND
√
5 years (see www.moxa.com/warranty)
w w w. m o x a . c o m
Web Console, Telnet Console, Serial Console, Windows Search
Utility
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64,
Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP
Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR
4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
2.4.x, 2.6.x
Real COM, TCP Server, TCP Client, UDP, RFC2217
SNMP MIB-II
Static, RIP-I, RIP-II
Reliability
Port Summary
Housing
Weight
Dimensions
1 KΩ, 150 KΩ
Serial Communication Parameters
Configuration Options
NPort S8000: General Specifications
Serial Ports
Ethernet Switch Ports
Console Ports
LED Indicators
ADDC® (automatic data direction control)
Software
VID 1 to 4094
256
10/100BaseT(X) auto negotiation speed, F/H duplex mode, and
auto MDI/MDI-X connection
Turbo Ring, Master, Coupler, Reserve
2 relay outputs with current carrying capacity of 1A @ 24 VDC
DIP Switches
Alarm Contact
RS-485 Data Direction
Control
Pull High/Low Resistor
for RS-485
Terminator for RS-485
Console Port
RS-232
RS-422
RS-485-4w
RS-485-2w
Switch Interface
RJ45 Ports
Serial Line Protection
4
RS-232/422/485
DB9 male
15 KV ESD protection for all signals
2 KV isolation protection
Serial Signals
Switch Properties
Priority Queues
Max. Number of
Available VLANs
VLAN ID Range
IGMP Groups
Number of Ports
Serial Standards
Connectors
[email protected]
Built-in buzzer and RTC (real-time clock)
Built-in WDT (watchdog timer)
Industrial Networking Solutions
General-purpose Device Servers
NPort® 5110
NPort® 5110-T
NPort® 5130
NPort® 5150
NPort® DE-211
NPort® DE-311
NPort® 5210
NPort® 5210-T
NPort® 5230
NPort® 5230-T
--1
--RJ45
--1
--RJ45
--1
--RJ45
1
----RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1
----DB9-M
√
--1
--DB9-M
√
----1
DB9-M
√
----1
DB25-F
√
----1
DB9-F
√
2
----RJ45
√
1
1
--TB
√
---
---
---
---
---
---
---
Ethernet Interface
10BaseT Ports
10/100BaseT(X) Ports
100BaseFX
Connector
Magnetic Isolation
Protection
Serial Interface
8
Serial Device Servers > Product Selection Guides
RS-232 Ports
RS-232/422 Ports
RS-232/422/485 Ports
Connector
15 KV ESD Protection
2 KV Isolation
Protection
Serial Communication
Parameters
Flow Control
Baudrate
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
110 bps to 230.4 Kbps
50 bps to 921.6 Kbps
50 bps to 230.4 Kbps
110 bps to 230.4 Kbps
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c, HTTP,
SMTP
DHCP, BOOTP, Telnet, TCP, UDP, IP, ICMP,
ARP
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP
Web Console
√
√
√
---
---
√
√
Serial Console
Telnet Console
Windows Utility
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
√
√
√
--√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux 2.4.x, 2.6.x
Onsite Configuration
Mini Screen with Push
Buttons
---
---
---
---
---
---
---
Metal
340 g
52 x 80 x 22 mm
Metal
340 g
Metal
340 g
Metal (IP30)
480 g
67 x 100.4 x 22 mm
Metal (IP30)
480 g
Metal (IP30)
340 g
Metal (IP30)
360 g
Physical Characteristics
Housing
Weight
Dimensions
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
0 to 55°C or -40 to
75°C
5 to 95% RH
-20 to 85°C
5 to 95% RH
-20 to 85°C
5 to 95% RH
-20 to 85°C
5 to 95% RH
-20 to 85°C
5 to 95% RH
-20 to 85°C
5 to 95% RH
-40 to 85°C
5 to 95% RH
-40 to 85°C
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 30 VDC
9 to 30 VDC
12 to 48 VDC
12 to 48 VDC
128.7/72/--- mA
200/106/--- mA
200/106/--- mA
180/100/--- mA
---/150/--- mA
325/190/--- mA
325/190/--- mA
---
---
---
---
---
---
---
0 to 55°C
0 to 55°C
0 to 55°C or -40 to 75°C
Power Requirements
Input Voltage
Power Consumption @
12/24/48 VDC
Power Consumption @
100/240 VAC
Regulatory Approvals
CE (EN55022 and EN55024 Class A), FCC
Part 15 Subpart B Class A
UL (UL60950-1), TÜV (EN60950-1)
DNV
---
CE (EN55022 Class B, EN55024 Class B),
FCC Part 15 Subpart B
UL (UL60950), TÜV (EN60950)
----EN60601-1-2 Class
--B, EN55011
---
---
WDT only
246034 hrs
--347822 hrs
√
134850 hrs
√
106955 hrs
EMC
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
Safety
Marine
UL (UL60950-1), TÜV (EN60950-1)
-----
---
Medical
---
---
Reliability
Buzzer, RTC, WDT
MTBF
Warranty
WDT only
WDT only
279122 hrs
246505 hrs
5 years (see www.moxa.com/warranty)
[email protected]
--225529 hrs
w w w. m o x a . c o m
8-3
Serial-to-Ethernet Solutions
General-purpose Device Servers
NPort® 5232
NPort® 5232-T
NPort® 5232I
NPort® 5232I-T
NPort® 5410
NPort® 5430
NPort® 5430I
NPort® 5450
NPort® 5450I
--1
--RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
--2
--TB
√
--2
--TB
√
4
----DB9-M
√
--4
--TB
√
--4
--TB
√
----4
DB9-M
√
----4
DB9-M
√
---
√
---
---
√
---
√
RTS/CTS, XON/XOFF
RTS/CTS, XON/XOFF
RTS/CTS, XON/XOFF
Ethernet Interface
8
10BaseT Ports
10/100BaseT(X) Ports
100BaseFX
Connector
Magnetic Isolation
Protection
Serial Interface
Serial Device Servers > Product Selection Guides
RS-232 Ports
RS-232/422 Ports
RS-232/422/485 Ports
Connector
15 KV ESD Protection
2 KV Isolation
Protection
Serial Communication
Parameters
Flow Control
Baudrate
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
RTS/CTS, XON/XOFF
110 bps to 230.4 Kbps
RTS/CTS, XON/XOFF
50 bps to 921.6 Kbps
RTS/CTS, XON/XOFF
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c, HTTP, SMTP, SNTP, Rtelnet, ARP
Web Console
√
√
√
√
√
√
√
Serial Console
Telnet Console
Windows Utility
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
--√
√
--√
√
--√
√
--√
√
--√
√
--√
√
--√
√
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux 2.4.x, 2.6.x
Onsite Configuration
Mini Screen with Push
Buttons
---
---
√
√
√
√
√
Metal (IP30)
360 g
67 x 100.4 x 22 mm
Metal (IP30)
380 g
67 x 100.4 x 35 mm
Metal (IP30)
740 g
158 x 103 x 33 mm
Metal (IP30)
Metal (IP30)
Metal (IP30)
Metal (IP30)
Physical Characteristics
Housing
Weight
Dimensions
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
0 to 55°C or -40 to 75°C
5 to 95% RH
-40 to 85°C
0 to 55°C (32 to 131°F)
5 to 95% RH
-20 to 70°C
Power Requirements
Input Voltage
Power Consumption @
12/24/48 VDC
Power Consumption @
100/240 VAC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
280/150/--- mA
509.4/200/--- mA
350/190/--- mA
320/175/--- mA
530/280/--- mA
350/190/--- mA
554/294/--- mA
---
---
---
---
---
---
---
√
206903 hrs
√
206903 hrs
√
206903 hrs
Regulatory Approvals
EMC
CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B Class A
Safety
Marine
Medical
UL (UL60950-1), TÜV (EN60950-1)
DNV
-----
EN60601-1-2 Class B, EN55011
Reliability
Buzzer, RTC, WDT
MTBF
Warranty
8-4
√
√
102344 hrs
87083 hrs
5 years (see www.moxa.com/warranty)
w w w. m o x a . c o m
√
206903 hrs
√
206903 hrs
[email protected]
Industrial Networking Solutions
General-purpose Device Servers
NPort® 5610-8
NPort®
5610-8-48V
NPort® 5630-8
NPort® 5650-8
NPort®
5650-8-M-SC
NPort®
5650-8-S-SC
NPort® 5610-16
NPort®
5610-16-48V
--1
--RJ45
--1
--RJ45
--1
--RJ45
--1
--RJ45
----1 (multi-mode)
SC
----1 (single-mode)
SC
--1
--RJ45
--1
--RJ45
1.5 KV
1.5 KV
1.5 KV
1.5 KV
---
---
1.5 KV
1.5 KV
8
----RJ45
√
8
----RJ45
√
--8
--RJ45
√
----8
RJ45
√
----8
RJ45
√
----8
RJ45
√
16
----RJ45
√
16
----RJ45
√
---
---
---
---
---
---
---
---
Ethernet Interface
10BaseT Ports
10/100BaseT(X) Ports
100BaseFX Ports
Connector
Magnetic Isolation
Protection
Serial Interface
8
Serial Device Servers > Product Selection Guides
RS-232 Ports
RS-232/422 Ports
RS-232/422/485 Ports
Connector
15 KV ESD Protection
2 KV Isolation
Protection
Serial Communication
Parameters
Flow Control
Baudrate
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
50 bps to 921.6 Kbps
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
Web Console
√
√
√
√
√
√
√
√
Serial Console
Telnet Console
Windows Utility
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
--√
√
--√
√
--√
√
--√
√
--√
√
--√
√
--√
√
--√
√
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux 2.4.x, 2.6.x
Onsite Configuration
Mini Screen with Push
Buttons
√
√
√
√
√
√
√
√
Metal (IP30)
Metal (IP30)
3340 g
3160 g
440 x 45 x 198 mm
Metal (IP30)
3380 g
Metal (IP30)
3360 g
Metal (IP30)
3380 g
Metal (IP30)
3380 g
Metal (IP30)
3420 g
Metal (IP30)
3260 g
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
100 to 240 VAC,
47 to 63 hz
±48 VDC
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
±48 VDC
---/---/135 mA
---
---
---
---
---
---/---/135 mA
141/93 mA
---
152/98 mA
158/102 mA
174/113 mA
164/110 mA
141/93 mA
---
Physical Characteristics
Housing
Weight
Dimensions
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
Power Requirements
Input Voltage
Power Consumption @
12/24/48 VDC
Power Consumption @
100/240 VAC
Regulatory Approvals
EMC
Safety
Marine
Medical
CE (EN55022 Class A, EN55024), FCC
Part 15 Subpart B Class A,
IEC61000-4-12
UL (UL60950-1), TÜV (EN60950-1)
----EN60601-1-2 Class B, EN55011
CE (EN55022 Class A, EN55024), FCC
Part 15 Subpart B Class A,
IEC61000-4-12
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
---
---
---
---
---
---
√
118405 hrs
√
117584 hrs
√
116914 hrs
√
116914 hrs
√
94928 hrs
√
94417 hrs
Reliability
Buzzer, RTC, WDT
MTBF
Warranty
√
√
97294 hrs
96758 hrs
5 years (see www.moxa.com/warranty)
[email protected]
w w w. m o x a . c o m
8-5
Serial-to-Ethernet Solutions
General-purpose Device Servers
NPort® 5630-16
NPort® 5650-16
NPort®
5650-16-M-SC
NPort®
5650-16-S-SC
NPort®
5610-8-DT
NPort®
5610-8-DT-J
NPort®
5650-8-DT
NPort®
5650I-8-DT
NPort®
5650-8-DT-J
--1
--RJ45
--1
--RJ45
----1 (multi-mode)
SC
----1 (single-mode)
SC
--2
--RJ45
--2
--RJ45
--2
--RJ45
--2
--RJ45
--2
--RJ45
1.5 KV
1.5 KV
---
---
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
--16
--RJ45
√
----16
RJ45
√
----16
RJ45
√
----16
RJ45
√
8
----DB9-M
√
8
----RJ45
√
----8
DB9-M
√
----8
DB9-M
√
----8
RJ45
√
---
---
---
---
---
---
---
√
---
Ethernet Interface
8
10BaseT Ports
10/100BaseT(X) Ports
100BaseFX Ports
Connector
Magnetic Isolation
Protection
Serial Interface
Serial Device Servers > Product Selection Guides
RS-232 Ports
RS-232/422 Ports
RS-232/422/485 Ports
Connector
15 KV ESD Protection
2 KV Isolation
Protection
Serial Communication
Parameters
Flow Control
Baudrate
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
50 bps to 921.6 Kbps
Software
Network Protocols
Web Console
Serial Console
Telnet Console
Windows Utility
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c, HTTP, SMTP,
SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
√
√
√
√
--------√
√
√
√
√
√
√
√
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c, HTTP, SMTP, SNTP,
Rtelnet, ARP, RFC2217
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux 2.4.x, 2.6.x
Onsite Configuration
Mini Screen with Push
Buttons
√
√
√
√
√
Metal (IP30)
Metal (IP30)
3400 g
3460 g
440 x 45 x 198 mm
Metal (IP30)
3440 g
Metal (IP30)
3440 g
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 75°C
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
--152/98 mA
√
√
√
√
Metal (IP30)
Metal (IP30)
1760 g
1170 g
197 x 44 x 135.5 mm
Metal (IP30)
1770 g
Metal (IP30)
1850 g
Metal (IP30)
1710 g
0 to 55°C
5 to 95% RH
-20 to 75°C
0 to 55°C
5 to 95% RH
-20 to 70°C
0 to 55°C
5 to 95% RH
-20 to 70°C
0 to 55°C
5 to 95% RH
-20 to 70°C
0 to 55°C
5 to 95% RH
-20 to 70°C
100 to 240 VAC,
47 to 63 hz
100 to 240 VAC,
47 to 63 hz
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
---
---
---
611/300/140
mA
611/300/140
mA
615/300/156
mA
1066/510/200
mA
615/300/156
mA
158/102 mA
174/113 mA
164/110 mA
---
---
---
---
---
Physical Characteristics
Housing
Weight
Dimensions
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
0 to 55°C
5 to 95% RH
-20 to 70°C
Power Requirements
Input Voltage
Power Consumption @
12/24/48 VDC
Power Consumption @
100/240 VAC
Regulatory Approvals
EMC
Safety
Marine
Medical
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
UL (UL60950-1), TÜV (EN60950-1)
--------EN60601-1-2
EN60601-1-2
EN60601-1-2
EN60601-1-2
Class B,
Class B,
Class B,
Class B,
EN55011
EN55011
EN55011
EN55011
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
---
---
---
---
---
---
---
---
---
---
√
163356 hrs
√
163356 hrs
√
163356 hrs
√
163356 hrs
√
163356 hrs
Reliability
Buzzer, RTC, WDT
MTBF
Warranty
8-6
√
√
√
91483 hrs
104767 hrs
87528 hrs
5 years (see www.moxa.com/warranty)
w w w. m o x a . c o m
√
87528 hrs
[email protected]
Industrial Networking Solutions
Industrial-grade Device Servers
NPort® IA5150
NPort® IA5150-T
NPort® IA5150I
NPort® IA5150I-T
NPort® IA5150-M-SC
NPort® IA5150-M-SC-T
NPort® IA5150I-M-SC
NPort® IA5150I-M-SC-T
NPort® IA5150-S-SC
NPort® IA5150-S-SC-T
NPort® IA5150I-S-SC
NPort® IA5150I-S-SC-T
NPort® IA5250
NPort® IA5250-T
2
--RJ45
2
--RJ45
--1 (multi-mode)
SC
--1 (multi-mode)
SC
--1 (single-mode)
SC
--1 (single-mode)
SC
2
--RJ45
1.5 KV
1.5 KV
---
---
---
---
1.5 KV
1
DB9-M/TB
√
1
DB9-M/TB
√
1
DB9-M/TB
√
1
DB9-M/TB
√
1
DB9-M/TB
√
1
DB9-M/TB
√
2
DB9-M
√
---
√
---
√
---
√
---
Ethernet Interface
10/100BaseT(X) Ports
100BaseFX Ports
Connector
Magnetic Isolation
Protection
Serial Interface
8
Serial Device Servers > Product Selection Guides
RS-232/422/485 Ports
Connector
15 KV ESD Protection
2 KV Isolation
Protection
Serial Communication
Parameters
Flow Control
Baudrate
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
110 bps to 230.4 Kbps
Software
Network Protocols
Configuration Options
Windows Real COM
Drivers
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS, SNMP V1/V2c, HTTP, SMTP, SNTP
Web Console, Serial Console, Telnet Console, Windows Utility
Fixed TTY Drivers
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux Real TTY Drivers
Linux 2.4.x, 2.6.x
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
Physical Characteristics
Housing
Weight
Dimensions
Plastic (IP30)
360 g
29 x 89.2 x 118.5 mm
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
0 to 55°C or -40 to 75°C
5 to 95% RH
-40 to 85°C
Power Requirements
Input Voltage
Power Consumption
12 to 48 VDC
360 mA @ 12 V,
195 mA @ 24 V
12 to 48 VDC
420 mA @ 12 V,
215 mA @ 24 V
12 to 48 VDC
500 mA @ 12 V,
250 mA @ 24 V
12 to 48 VDC
510 mA @ 12 V,
260 mA @ 24 V
12 to 48 VDC
470 mA @ 12 V,
210 mA @ 24 V
12 to 48 VDC
490 mA @ 12 V,
250 mA @ 24 V
12 to 48 VDC
440 mA @ 12 V,
200 mA @ 24 V
Regulatory Approvals
EMC
Safety
Hazardous Location
ATEX
Marine
EMS
IEC
Dust-proof
CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
UL (UL60950-1), UL508, TÜV (EN60950-1)
UL/cUL Class 1 Division 2 Groups A, B, C and D
Class I, Zone 2
DNV
EN61000-4-2 (ESD), Level 3; EN61000-4-3 (RS), Level 3; EN61000-4-4 (EFT), Level 4; EN61000-4-5 (Surge), Level 3; EN61000-4-6 (CS), Level 3; EN61000-4-8;
EN61000-4-11; EN61000-4-12
IEC60068-2-27 (Shock); IEC60068-2-32 (Freefall); IEC60068-2-6 (Vibration)
IP30
IP30
IP30
IP30
IP30
IP30
IP30
Reliability
Buzzer, RTC, WDT
MTBF
Warranty
√
√
183747 hrs
195614 hrs
5 years (see www.moxa.com/warranty)
√
183747 hrs
√
195614 hrs
[email protected]
√
183747 hrs
w w w. m o x a . c o m
√
195614 hrs
√
194765 hrs
8-7
Serial-to-Ethernet Solutions
Embedded Device Servers
MiiNePort E1
MiiNePort E1-T
NE-4110S
Type
Drop-in module
Ready-to-go stand-alone modules
Dimensions
33.9 x 16.25 x 13.5 mm
57 × 40 mm
57 × 40 mm
57 × 40 mm
1
RJ45
1
RJ45
1
RJ45
1.5 KV
1.5 KV
Standard Compliance
Radio Frequency Type
Wireless Security
-------
Network Modes
NE-4110A
NE-4120S
NE-4120A
NE-4100T
WE-2100T
Small metal housing
57 × 40 mm
26-pin dual-in-line
package
45 × 36 mm
1
1
5-pin pin header
1
26-pin dual-in-line
1
44-pin dual-in-line
1.5 KV
1.5 KV
1.5 KV
1.5 KV
1.5 KV
-------
-------
-------
-------
-------
---
---
---
---
---
---
IEEE 802.11a/b/g
DSSS, CCK, DFDM
SEP, SPA, SPA2, 802.11i
Infrastructure (a/b/g),
Ad Hoc (b/g)
1 (data port)
-----
1 (console port)
1 (data port)
----1 (data port)
1 (data port)
---
--1 (data port)
2 (1 data port, 1 console port)
---------
4
4
4
Form Factor
54 x 40 x 13.3 mm
Ethernet Interface
8
10/100BaseT(X) Ports
Connector
Magnetic Isolation
Protection
WLAN Interface
Serial Device Servers > Product Selection Guides
Serial Interface
TTL Ports
RS-232 Ports
RS-232/422 Ports
Serial Communication
Parameters
Flow Control
Baudrate
Programmable GPIO
Pins
Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF
50 bps to 230.4 Kbps* (supports
non-standard baudrates)
110 bps to 230.4 Kbps
3
4
4
50 bps to 921.6 Kbps
---
Software
Network Protocols
ICMP, IP, TCP, UDP, DHCP, Telnet, HTTP, SNMP V1/V2c, SMTP
ARP, TFTP, Auto IP, BOOTP
ARP
Web/Serial/Telnet Console, Windows Utility
√
---
DNS, SNTP, SSH, HTTPS
Configuration Options
Serial Command Mode
Windows Real COM
Drivers
Fixed TTY Drivers
Linux Real TTY Drivers
Windows 95, 98, ME, NT, 2000, XP x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE 5.0/6.0, XP Embedded
Operation Modes
TCP Server, TCP Client, UDP, Real COM mode,
Modem Mode, RFC2217
Real COM, TCP Server, TCP Client, UDP
0 to 55°C or -40 to 85°C
5 to 95% RH
-40 to 85°C
0 to 55°C or -40 to 75°C
3.3 VDC (±5%)
160 mA @ 3.3 VDC max.
5 VDC (±5%)
5 VDC (±5%)
290 mA @ 5 VDC max.
EN55022:1998, Class B
(radiated & conducted emissions);
EN55024:1998
(direct & indirect ESD, electrical fast-transient/
burst immunity, power frequency magnetic
field immunity)
CE (EN55022 Class A), FCC Part 15 Subpart B Class A
---
---
---
---
√
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux 2.4.x, 2.6.x
Real COM, TCP Server,
TCP Client, UDP,
RFC2217
Environmental Limits
Operating Temparture
Operating Humidity
Storage Temperature
0 to 55°C
5 to 95% RH
-20 to 70°C
-20 to 70°C
Power Requirements
Input Voltage
Power Consumption
5 VDC (±5%)
5 VDC (±5%)
5 VDC (±5%)
3.3 VDC (±5%)
540 mA (at full speed)
Regulatory Approvals
EMC
CE (EN55022 and
EN55024 Class A, ETSI
EN 301 489-17, ETSI EN
301 489-1)
Reliability
Watchdog Timer
MTBF
Warranty
√
--5 years (see www.moxa.com/warranty)
√
290276 hrs
√
289573 hrs
* Baudrates up to 921.6 Kbps available by request
8-8
w w w. m o x a . c o m
[email protected]
√
289573 hrs
√
289573 hrs
√
288173 hrs
√
505288 hrs
Industrial Networking Solutions
Introduction to Serial Device Servers
Device server technology makes device networking easy
Device servers are used to connect serial devices to Ethernet LANs,
and are able to transmit data both to and from the serial device.
Moxa’s NPort® line of device servers are essentially pre-programmed
computers that have a real-time OS and built-in TCP/IP protocol suite
that allows you to access, manage, and configure remote facilities and
equipment from anywhere in the world over the Internet.
No Restrictions on Host Type or Operating System
Any host computer that supports the TCP/IP protocol can access the
NPort®’s serial ports, eliminating the need for special-purpose drivers.
In addition, you will not be held back by your PC’s limited number of
serial bus slots.
8
Real COM/TTY Drivers for Existing Software
Serial Device Servers > Introduction to Serial Device Servers
NPort® device servers also come with Real COM/TTY drivers for
accessing devices through a “virtual” COM or TTY port.
Serial Device Server Selection Table
Number of Serial
Ports
1
General-purpose Device Servers
RS-232
NPort® 5110
RS-422/485
RS-232/422/485
NPort® 5130
NPort® DE-211
NPort® DE-311
NPort® 5150
NPort® IA5150
NPort® IA5150-M-SC
NPort® IA5150-S-SC
Device Servers with
Optical Isolation
Device Servers for Wide
Temperature Applications
NPort® IA5150I
NPort® IA5150I-M-SC
NPort® IA5150I-S-SC
NPort® 5110-T
NPort® IA5150-T
NPort® IA5150I-T
NPort® IA5150-M-SC-T
NPort® IA5150-S-SC-T
NPort® IA5150I-M-SC-T
NPort® IA5150I-S-SC-T
2
NPort® 5210
NPort® 5232
NPort® 5230
NPort® IA5250
NPort® 5232I
NPort® 5210-T
NPort® 5230-T
NPort® 5232-T
NPort® IA5250-T
NPort® 5232I-T
4
NPort® 5410
NPort® 5430
NPort® 5450
NPort® 5430I
NPort® 5450I
---
8
NPort® 5610-8
NPort® 5610-8-48V
NPort® 5610-8-DT
NPort® 5610-8-DT-J
NPort® 5630-8
NPort® 5650-8
NPort® 5650-8-M-SC
NPort® 5650-8-S-SC
NPort® 5650-8-DT
NPort® 5650-8-DT-J
NPort® 5650I-8-DT
---
16
NPort® 5610-16
NPort® 5610-16-48V
NPort® 5630-16
NPort® 5650-16
NPort® 5650-16-M-SC
NPort® 5650-16-S-SC
---
---
Note: See Chapter 7, “Terminal Servers,” for information about our NPort® 6000 series and CN2600 series of serial-to-Ethernet terminal servers.
[email protected]
w w w. m o x a . c o m
8-9
Serial-to-Ethernet Solutions
NPort® Provides a Choice of Operation Modes
Socket Modes
8
TCP Server Mode
TCP Client Mode
When the NPort® is configured
for TCP Server Mode, each serial
1
port is assigned a unique IP:Port
TCP/IP
Ethernet
combination on the TCP/IP network,
2
and the NPort® waits passively
TCP Server
for a host computer to establish a
connection with the attached serial
RS-23
RS-232
device. TCP Server mode supports
up to 4 simultaneous connections,
Device
allowing multiple hosts to collect
1 Request a
data from the same serial device at
connection
2 Proceed with
the same time.
When the NPort® is configured
for TCP Client mode, the NPort®
1
establishes a TCP connection between
TCP/IP
Ethernet
the attached device and a specified
2
host computer when data is received
TCP Client
from the attached device. After the
data has been transferred, the NPort®
automatically closes the connection.
RS-2
RS-232
TCP Client mode supports up to 4
Device
simultaneous connections, allowing
1 Request a
multiple hosts to collect data from the
connection
2 Proceed with
same serial device at the same time.
data transmission
data transmission
Serial Device Servers > Introduction to Serial Device Servers
UDP Mode
UDP mode supports up to 4 IP groups. In UDP mode, the
attached device can exchange data simultaneously with up to
4 network destinations, and at a higher speed than when using
TCP. This mode is ideal for message display applications.
TCP/IP
Ethernet
Directly proceed with
data transmission
(no connection required)
Device
RS-232
R
Driver Modes
RFC2217 Mode
Real COM Mode
When configured for Real COM mode,
each serial port is assigned an IP:Port
combination that is mapped to a host
computer’s local COM or TTY port using
Moxa’s NPort® drivers. Legacy applications
can access the attached serial device using
the host’s local COM or TTY port, without
the need to modify serial COM software to
account for network protocols.
COM3=IP : Port
TCP/IP
Ethernet
Driver Mode
When the NPort® is configured for RFC2217 mode,
each serial port is assigned an IP:Port combination
that is mapped by RFC2217-compliant drivers to
a virtual COM port. The RFC2217 protocol defines
general COM port control options based on the
Telnet protocol. The NPort® supports any third
party driver that is RFC2217-compliant.
RS-232
RS
Device
Other Modes
Pair Connection Mode
When configured for Pair Connection mode, two NPort® device servers can be used to transmit RS-232 signals over Ethernet, and in this
way overcome the 15-meter limitation imposed by the RS-232 standard. One NPort® connects to the PC’s COM port, and the other NPort®
connects to the serial device. The two NPort® device servers are either connected to each other with a cross-over Ethernet cable, or are each
connected to an Ethernet LAN or WAN. Both data and modem control signals can be exchanged between the PC and device over Ethernet, but
DCD signals are not supported.
8-10
Ethernet Modem Mode
Reverse Telnet Mode
When configured for Ethernet
Modem mode, the serial port on
the NPort® behaves as if it were
attached to a modem, except that
data is transmitted over a network
instead of over phone lines. Ethernet
Modem Mode enables network
access for legacy software that was
originally designed to transmit data
by modem.
When configured for Reverse Telnet mode, the
NPort® device server’s serial ports provide
a connection to a server, with connections
initiated by a host over Ethernet. This is similar
to TCP server mode, except that Reverse
Telnet mode also provides Telnet-style CR/LF
conversion. Reverse Telnet mode can be used
for remote console management, in which the
NPort® is used to enable network access to
the serial console ports of different equipment,
such as routers, switches, and servers.
w w w. m o x a . c o m
[email protected]
Industrial Networking Solutions
Mode Selection Flowchart
Start
NO
YES Using socket
program?
TCP
Which protocol,
TCP or UDP?
Host application is
server or client?
Using legacy
COM-based software?
Host requires more
COM ports?
YES
NO
Using MOXA's
drivers?
UDP
Need to extend
serial transmission
range?
NO
NO
YES
YES
8
Client
Need to perform
console
management?
Server
NO
YES
NO
Reverse
Telnet
Contact your
saleperson.
YES
TCP Client
Mode
TCP Server
Mode
RFC2217
Mode or TCP
Server Mode
UDP Mode
Pair
Connection
Modes
RFC2217
Mode
Real COM
Mode
Typical Applications
Use only one IP address to control multiple serial devices over the network
Automatic or remote data acquisition can be accomplished with
NPort® 5000 device servers, which only require one IP address to
connect up to 16 serial devices to an Ethernet network. By specifying
the IP address and TCP port number, a host computer can access the
serial devices connected to the NPort® 5000 from over the network. In
the example shown here, data from the NPort® 5410’s first serial port
can be obtained by connecting to 192.168.10.2:4001.
Remote host
Local host
Ethernet
PLC
Serial Device Servers > Remote host
Need serial control
parameters?
Fire Alarm Temprature Entrance
Contral
Contral
Contral
Use server sharing from a central location for greater device management flexibility
Serial devices connected to the NPort® 5000 device server can
communicate over the network with more than one host computer.
Windows Host A
Windows Host B
Ethernet
RS-232
Host A’s
COM3
Host A’s
COM4
Host B’s
COM3
Host B’s
COM4
Centralize RS-422/485 serial device control
Up to 31 RS-485 devices, or 9 RS-422 devices, can be connected to
each serial port on the NPort® 5000 device server. The web console or
Windows utility can be used to configure RS-422 or RS-485 operation
for each port, with both 2-wire and 4-wire RS-485 supported.
[email protected]
Host A
Host B
Ethernet
NPort 5430/5430I
4-wire
RS-422
2- or 4-wire RS-485 Multidrop
w w w. m o x a . c o m
8-11
Serial-to-Ethernet Solutions
NPort® Administrator Makes Installation Easy
NPort® Administrator is designed to make it easy to install and
configure NPort® 5000 device servers over the network. Five groups
of functions are supported to allow off-line COM mapping, device
monitoring, and searching for NPort® device severs over the network.
Both NPort® Administrator and an IP Serial Library are bundled with
NPort®’s integrated software suite, giving you everything you need to
manage, monitor, and reconfigure your NPort® from remote locations.
Configuration Features
•
•
•
•
•
•
Broadcast search over the LAN for NPort® device servers
Select and configure the NPort®’s operation mode
Upgrade the NPort®’s firmware
Export and import the NPort’s configurations
Monitor the NPort’s status
Auto IP report
8
Serial Device Servers > 4-wire RS-422
Web Console Provides Exceptional Convenience
NPort® 5000 device servers are easily configured over the network with the web console or Telnet console.
Network Settings
Serial Settings
• IP, netmask, gateway
• Static IP, DHCP, BOOTP
• DNS server
•
•
•
•
Baudrate
Data bits, stop bit, parity
Flow control
Communication interface
Operation Settings
•
•
•
•
•
•
•
•
8-12
Operation mode
TCP alive check time
Inactivity time
Delimiter
Force transmit
Packet length
Allow driver control
Maximum connection
w w w. m o x a . c o m
[email protected]
Industrial Networking Solutions
IP Serial Library
What is IP Serial Library?
The IP Serial Library is a collection of Windows functions for NPort®
5000 device servers. Serial command sets and common subroutines
are provided. The purpose of the library is to help reduce complexity
and increase efficiency when programming serial communication
applications that run over a TCP/IP network. For example, Telnet
is limited because it can only transfer data but cannot monitor or
configure serial line parameters. The IP Serial Library can be used to
add new functionality to your Telnet sessions.
Use IP Serial Library for easier socket-based serial COM programming
For programmers who are familiar with serial communication, the IP
Serial Library provides well-designed function calls that have the same
style as Moxa’s PComm Library.
The IP Serial Library is amazingly simple and easy to understand.
By including the library in your VB, C, or Delphi programming
environment, you will be able to develop TCP/IP applications that can
control serial communication parameters.
When Real COM mode is used, the NPort® serial device servers use
two TCP ports for communication between an attached device and
a host computer’s Real COM driver. The two ports, a data port and a
command port, provide pure data transfer without requiring encoding
and decoding. With the IP Serial Library, only one port is used to
communicate with a user’s application, and no encoding or decoding
is required.
8
IP Serial Library Example
IP Serial API Function List
Server Control
Port Control
Input/Output Data
Port Status Inquiry
Miscellaneous
nsio_init
nsio_open
nsio_read
nsio_lstatus
nsio_break
nsio_end
nsio_close
nsio_SetReadTimeouts
nsio_data_status
nsio_break_on
nsio_resetserver
nsio_ioctl
nsio_write
---
nsio_break_off
nsio_checkalive
nsio_fl owctrl
nsio_SetWriteTimeouts
---
nsio_breakcount
---
nsio_DTR
---
---
---
---
nsio_RTS
---
---
---
---
nsio_lctrl
---
---
---
---
nsio_baud
---
---
---
---
nsio_resetport
---
---
---
[email protected]
w w w. m o x a . c o m
Serial Device Servers > 4-wire RS-422
char NPortip=“192.168.1.10”;
char buffer[255];int port = 1;
/*data buffer, 255 chars */
int portid;
/*port handle*/
nsio_init();
/*initialize IP Serial Library*/
portid = nsio_open(NPortip, port);
/*1st port, NPort IP=192.168.1.10 */
nsio_ioctl(portid, B9600, (BIT_8 | STOP_1 | P_NONE) );
/*set 9600, N81 */
sleep(1000);
/* wait for 1000 ms for data */
nsio_read(port, buffer, 200);
/* read 200 bytes from port 1 */
nsio_close(portid);
/* clost this serial port */
nsio_end();
/* close IP Serial Library */
8-13
Serial-to-Ethernet Solutions
CASE STUDY
Power Generation
Remote Monitoring and Control of a Windmill Generator
As concerns over global warming continue to grow, green technologies
are becoming increasingly popular. Wind turbine companies provide
an excellent alternative to burning fossil fuels by harnessing kinetic
energy from the wind and converting it into electricity. A typical wind
farm may include over 80 wind turbines, so maintaining efficient
and reliable networks to manage and control these installations is
imperative.
8
Serial Device Servers > Power Generation
Each wind turbine includes a generator and a variety of serial
components such as a water cooler, high voltage transformer,
ultrasonic wind sensors, yaw gear, blade bearing, pitch cylinder, and
hub controller. All of these components are controlled by a PLC and
communicate with the host on the ground. Due to the total integration
of these devices into an Ethernet network, one of our customers in
the wind turbine industry needed a serial-to-Ethernet solution that can
operate reliably for years without interruption.
Key Products
Application Requirements
• Must be able to connect with many serial devices, with total
integration of the devices into an Ethernet network.
• The system must exhibit high reliability and performance, and be
easy to maintain.
Why Moxa?
• Long MTBF with high reliability and effective system maintenance
• Small size for easy configuration
• High performance serial-to-Ethernet solution
Application Topology
• Small size for easy installation
• Versatile socket operation
modes, including TCP Server,
TCP Client, and UDP
• Easy-to-use Windows utility for
configuring multiple device
servers
• Supports 10/100M Ethernet
• Patented ADDC® (Automatic
Data Direction Control) for
2-wire and 4-wire RS-485
• Built-in 15 KV ESD protection
for all serial signals
• SNMP MIB-II for network
management
NPort® 5130
Fiber
Twisted Pair
Serial
8-14
w w w. m o x a . c o m
[email protected]
Industrial Networking Solutions
CASE STUDY
Automatic Meter Reading
Automatic Meter Reading for a Centralized Power Meter Application
Automated meter reading (AMR) technology automatically collects
data from devices such as electricity, water, and gas meters, and
transfers that data to a central database for billing or analysis.
• Data transmission from each group of power meters to the control
room
• Additional wiring space must be kept to a minimum
• Only a limited number of public IP addresses could be used for the
entire building
Key Products
NPort® 5130
Application Requirements
• Use the existing Ethernet infrastructure to transmit power meter
data
• Use NPort® 5130 device servers to connect power meters over
RS-485
Why Moxa?
• The NPort® 5130 offers an effective serial-to-Ethernet solution for
data transmission
• Do not need to spend additional effort and cost for wiring
Application Topology
• Real COM/TTY drivers for Windows
and Linux
• Standard TCP/IP interface and
versatile operation modes
• Easy-to-use Windows utility for
configuring multiple device servers
• Built-in 15 KV ESD protection for all
serial signals
• SNMP MIB-II for network management
• Configure by Telnet or web browser
• Adjustable termination resistor for
RS-485 ports
Electric Meter
[email protected]
w w w. m o x a . c o m
8
Serial Device Servers > Automatic Meter Reading
A particular tower in the Middle East has a large number of devices
and communication media on each floor. In addition, the control room
needs to gather and monitor a great deal of information, including
security alarm signals, air conditioner controls, signal controls, and
power meters. However, there was insufficient space to install serial
communication wiring to connect the power meters to the control
room. Since an Ethernet network was already installed, the client
wanted a solution that satisfied the following requirements:
Twisted Pair
Serial
8-15
Serial-to-Ethernet Solutions
NPort® S8000 Series
Combo switch / serial device server
› 4-port RS-232/422/RS-485 serial device server
NPort S8455I-MM-SC
• Serial QoS for configuring serial data transmission priority
• 2 KV (DC) isolation protection for each serial port
• Adjustable pull high/low resistor for RS-485 ports
› 5-port managed Ethernet switch built in
• Two fiber Ethernet ports and three Ethernet ports
• Ethernet redundancy with Turbo Ring® (recovery time < 20 ms)
or RSTP/STP (IEEE 802.1w/D) supported
• QoS, IGMP-snooping/GMRP, VLAN, LACP, SNMPv1/v2c/v3,
RMON supported
• Surge protection for serial, power, and Ethernet
8
Serial Device Servers > NPort® S8000 Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Overview
The first model available from the NPort® S8000 series is the NPort®
S8455I-MM-SC, which combines an industrial device server with a
full-function managed Ethernet switch. The NPort® S8455I-MM-SC
integrates 2 fiber ports, 3 Ethernet ports, and 4 RS-232/422/485 serial
ports, allowing you to save space in your cabinet, reduce your overall
power consumption, and reduce your costs since you will not need to
purchase separate switch and serial device server products.
Supports all NPort® 5000 Series Device Server Functions
The NPort® S8455I-MM-SC supports the complete array of NPort®
5000 series device server functions. Network your existing serial
devices by connecting up to 4 serial devices through each of the
5 Ethernet ports, with only basic configuration required. Data
transmission between the serial and Ethernet interfaces is bidirectional.
Full-function Managed Ethernet Switch
The NPort® S8455I-MM-SC has a built-in full-function managed
Ethernet switch that supports QoS, IGMP-snooping/GMRP, VLAN,
Port Trunking, SNMPv1/v2c/v3, and IEEE 802.1X, allowing you to
handle virtually any kind of application. Ethernet redundancy, which
is used to increase the reliability and availability of your industrial
Ethernet network, is provided by Moxa’s own Turbo Ring® technology
(recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D).
Couple Several Turbo Rings for Distributed Applications
For some systems, it may not be convenient to connect all devices in
the system to create one BIG redundant ring, since some devices could
be located at a remote site. The NPort® S8455I-MM-SC supports
8-16
w w w. m o x a . c o m
Turbo Ring’s “Ring Coupling” function, which allows you to separate
distributed devices into different smaller redundant rings, without a
control line, and in such a way that the smaller rings will still be able to
communicate with each other.
[email protected]
Industrial Networking Solutions
Rugged Design with Complete Protection
› UL508 safety
›
›
›
To meet customers’ critical application requirements, the NPort® S8455I-MMSC has been certified to meet the UL 508 national and international standard.
The UL 508 standard covers the safety requirements for industrial control
equipment.
3-way surge protection
The NPort® S8455I-MM-SC is equipped with a surge protector for power,
Ethernet interface, and serial interface for protection against voltage spikes.
Level 4 ESD
The NPort® S8455I-MM-SC supports high level, 8/15 KV, ESD protection to
avoid damage from static electricity.
2 KV Serial Isolation
Each serial port is protected by 2 KV of isolation against harmful currents from
high voltages caused by a difference in ground potential between points in a
communications system.
8
Roadway Traffic Monitoring and Control
Intelligent transportation systems (ITS) are playing a major role in
modern transportation construction, with ITS technology applied to
roadway traffic control systems. In general, ITS involves integrating
communication, control, and electronics technologies, and is used
to monitor and manage traffic flow, reduce congestion, provide
alternative routes to travelers, and enhance productivity to save lives,
time, and money. Traffic monitoring and control systems are usually
housed in a small cabinet located by the roadside or at an intersection.
Such systems usually include a camera for monitoring traffic, a traffic
light control system, as well as other devices. The NPort S8455I-MMSC is the best choice for traffic monitoring and control applications,
since the compact size and all-in-one switch/device-server design
saves a significant amount of space in a small cabinet.
Serial Device Servers > NPort® S8000 Series
Typical Applications
Solar Power Station
All solar power stations include three major devices—a power inverter,
a PLC, and meters. The power inverter converts the energy generated
by the plant into the power that is transmitted to end-users. The PLC
controls the sun tracking system of the base. These devices are often
serial devices, although some may be Ethernet-ready. Now you can
connect all of these Ethernet and serial devices to the control center
easily and economically with one With the NPort® S8455I-MM-SC.
The Ethernet redundancy function and ring structure increase the
reliability and availability of the system. The NPort® S8000 series is
definitely the best solution for this type of solar power system.
[email protected]
w w w. m o x a . c o m
8-17
Serial-to-Ethernet Solutions
Appearance
Power input (terminal block)
4 DIP switches for
Turbo Ring settings
Relay output, DI (terminal block)
LED indicators
Multi-mode fiber port
Serial port (DB9 male)
Ethernet port (RJ45)
8
General Specifications
Serial Device Servers > NPort® S8000 Series
Port Summary
Power Requirements
Serial Ports: 4 RS-232/422/485 ports
Ethernet Switch Ports: 3 RJ45 copper ports, 2 multi-mode fiber
ports
Console Ports: 1 (8-pin RJ45 connector)
LED Indicators: PWR1, PWR2, READY, MASTER, COUPLER, LINK4,
LINK5
Input Voltage: 12 to 48 VDC
Power Consumption: 935mA @ 12 V, 470 mA @ 24 V
Physical Characteristics
Housing: Metal
Weight: 995 g
Dimensions: 73.1 x 134 x 105 mm (2.88 x 5.27 x 4.13 in)
Environmental Limits
EMC: FCC Class A, CE Class A
Safety: UL-508
EMS:
IEC 61000-4-2, Level 4 (ESD)
IEC 61000-4-4, Level 4 (EFT)
IEC 61000-4-5 for serial port, Level 1 (Surge)
IEC 61000-4-5 for LAN port, Level 2 (Surge)
IEC 61000-4-5 for Power Line, Level 3 (Surge)
Warranty
Operating Temperature: 0 to 60°C (32 to 140°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Device Server Specifications
Serial Interface
Number of Ports: 4
Serial Standards: RS-232/422/485
Connectors: DB9 male
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 55 Ω, 120 Ω
Console Port: Dedicated RS-232 console port (8-pin RJ45)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS and XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
8-18
Regulatory Approvals
w w w. m o x a . c o m
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Software
Configuration Options: Web Console, Telnet Console, Serial
Console, Windows Search Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Operation Modes: Real COM, TCP Server, TCP Client, UDP,
RFC2217
Management: SNMP MIB-II
IP Routing: Static, RIP-I, RIP-II
Reliability
Alert Tools: Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
[email protected]
Industrial Networking Solutions
Ethernet Switch Specifications
Ethernet Interface
Optical Fiber Interface
Standards:
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100Base FX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Network Protocols: ICMP, IP, TCP, UDP, ARP, Telnet, DNS, HTTP,
SMTP, SNTP, IGMPv1/v2 device, GVRP, SNMPv1/v2c/v3, DHCP
Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP,
GMRP, LACP, RMON
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB,
Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control: IEEE 802.3x flow control, back pressure flow control
interface
Type: Multi-mode
Distance: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Min. TX Output: -20 dBm
Max. TX Output: -14 dBm
Sensitivity: -34 to -30 dBm
Switch Properties
Priority Queues: 4
Max. Number of Available VLANs: 64
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256
Switch Interface
RJ45 Ports: 10/100BaseT(X) auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection
DIP Switches: Turbo Ring, Master, Coupler, Reserve
Alarm Contact: 2 relay outputs with current carrying capacity of 1A
@ 24 VDC
Serial Device Servers > NPort® S8000 Series
Dimensions
105 mm (4.13 in)
113.8 mm (4.48 in)
125 mm (4.92 in)
73 mm (2.87 in)
8
2 mm (0.08 in)
Pin Assignment
Serial Port (DB9 male connector)
DB9 male connector
1 2 3 4 5
6 7 8 9
Console Port (RJ45)
Ethernet Port (RJ45)
PIN
RS-232
PIN
Signal
1
DSR
1
RXD+
2
RTS
2
RXD-
3
GND
3
TXD+
4
TxD
4
---
5
RxD
5
---
–
6
DCD
6
TXD-
–
–
7
CTS
7
–
–
8
RTS
8
PIN
RS-232
RS-422/485-4w
RS-485-2w
1
DCD
TxD-(A)
–
2
RxD
TxD+(B)
–
3
TxD
RxD+(B)
Data+(B)
4
DTR
RxD-(A)
Data-(A)
5
GND
GND
GND
6
DSR
–
7
RTS
8
CTS
8-pin RJ45 connector
1
8
Ordering Information
Available Models
Package Checklist
NPort S8455I-MM-SC: 5-port Ethernet switch and 4-port serial device server combo
•
•
•
•
•
[email protected]
NPort S8455I-MM-SC
Two power jack to TB power cables
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
w w w. m o x a . c o m
8-19
Serial-to-Ethernet Solutions
NPort® 5100 Series
1-port RS-232/422/485 serial devic
device servers
› Real COM/TTY drivers for Windows and Linux
› Standard TCP/IP interface and versatile operation modes
› Easy-to-use Windows utility for configuring multiple device
servers
› Built-in 15 KV ESD protection for all serial signals
› SNMP MIB-II for network management
› Configure by Telnet or web browser
› Adjustable termination resistor for RS-485 ports
8
Serial Device Servers > NPort® 5100 Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Overview
NPort® 5100 device servers are designed to make serial devices
network-ready in an instant. The small size of the servers makes
them ideal for connecting devices such as card readers and payment
terminals to an IP-based Ethernet LAN. Use the NPort® 5100 device
servers to give your PC software direct access to serial devices from
anywhere on the network.
Most Cost-effective Serial-to-Ethernet Solution
Using serial device servers to connect legacy serial devices to Ethernet
is now commonplace, and users expect device servers to be costeffective and to provide a broad selection of useful functions. With
their full support of Microsoft and Linux operating systems and solid
5-year warranty, the NPort® 5100 series device servers provide the
best choice for serial-to-Ethernet converters.
Standard TCP/IP Interface and Broad Choice of Operation Modes
The NPort® 5100 device servers can be configured for TCP Server,
TCP Client, UDP Server/Client, Pair Connection, or Ethernet Modem
mode, ensuring compatibility with software based on a standard
network API (e.g., Winsock or BSD Sockets).
Real COM/TTY Drivers for Existing Software
The Real COM/TTY drivers provided with the NPort® 5100
device servers allow you to continue using software designed for
communicating through COM/TTY ports. Installation and configuration
is painless, and allows your serial devices and PC to communicate
seamlessly over a TCP/IP network. Using Moxa’s Real COM/TTY
drivers is an excellent way to preserve your software investment,
while still allowing you to enjoy the benefits of networking your serial
devices.
Easy to Troubleshoot
NPort® 5100 device servers support SNMP V2, which can be used to
monitor all units over Ethernet. Each unit can be configured to send
trap messages automatically to the SNMP manager when user-defined
errors are encountered. For users who do not use SNMP manager, an
8-20
w w w. m o x a . c o m
e-mail alert can be sent instead. Users can define the trigger for the
alerts using Moxa’s Windows utility, or the web console. For example,
alerts can be triggered by a warm start, a cold start, or a change in
password.
[email protected]
Industrial Networking Solutions
Appearance
NPort® 5150
NPort® 5110
NPort® 5130
Ethernet
RJ45 10/100 Mbps
Reset button
Power input
Power jack
12 to 48 VDC
Ethernet
RJ45 10/100 Mbps
Reset button
Power input
Power jack 12 to 48 VDC
Power input
Power jack
12 to 48 VDC
Reset button
Ethernet
RJ45 10/100 Mbps
DK-35A DIN-Rail Kit
8
RS-232/422/485
Specifications
Ethernet Interface
RS-232
RS-422/485
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Physical Characteristics
Serial Interface
Number of Ports: 1
Serial Standards:
NPort® 5110: RS-232
NPort® 5130: RS-422/485
NPort® 5150: RS-232/422/485
Connector: DB9 male
Serial Line Protection: 15 KV ESD protection for all signals
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Serial Communication Parameters
Housing: Metal
Weight: 340 g
Dimensions:
Without ears: 52 x 80 x 22 mm (2.05 x 3.15 x 0.87 in)
With ears: 75.2 x 80 x 22 mm (2.96 x 3.15 x 0.87 in)
Environmental Limits
Serial Device Servers > NPort® 5100 Series
Available Accessory
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 85°C (-4 to 185°F)
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption:
NPort® 5110: 128.7 mA @ 12 V, 72 mA @ 24 V
NPort® 5130/5150: 200 mA @ 12 V, 106 mA @ 24 V
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF
Baudrate:
NPort® 5110: 110 bps to 230.4 Kbps
NPort® 5130/5150: 50 bps to 921.6 Kbps
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), TÜV (EN60950-1)
Serial Signals
Reliability
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
NPort® 5110: 279122 hrs
NPort® 5130: 246505 hrs
NPort® 5150: 246034 hrs
Software
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP
Configuration Options: Web Console, Serial Console (NPort
5110/5150 only), Telnet Console, Windows Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
[email protected]
w w w. m o x a . c o m
8-21
Serial-to-Ethernet Solutions
Dimensions
NPort® 5110
NPort® 5130
12-48
NPort® 5150
12-48
12-48
Port 1 RS-422/485
Port 1 RS-232/422/485
8
Serial Device Servers > NPort® 5100 Series
Pin Assignment
DB9 male connector
1 2 3 4 5
NPort® 5110 (RS-232)
NPort® 5130 (RS-422/485)
RS-232
PIN
RS-422/485-4w
RS-485-2w
1
DCD
1
TxD-(A)
–
1
DCD
TxD-(A)
2
RxD
2
TxD+(B)
–
2
RxD
TxD+(B)
–
3
TxD
3
RxD+(B)
Data+(B)
3
TxD
RxD+(B)
Data+(B)
4
DTR
4
RxD-(A)
Data-(A)
4
DTR
RxD-(A)
Data-(A)
5
GND
5
GND
GND
5
GND
GND
GND
6
DSR
6
–
–
6
DSR
–
–
7
RTS
7
–
–
7
RTS
–
–
8
CTS
8
–
–
8
CTS
–
–
6 7 8 9
PIN RS-232 RS-422/485-4w
RS-485-2w
–
Ordering Information
Available Models
NPort® 5110: 1-port RS-232 device server, 0 to 55°C operating temperature
NPort® 5130: 1-port RS-422/485 device server, 0 to 55°C operating temperature
NPort® 5150: 1-port RS-232/422/485 device server, 0 to 55°C operating temperature
NPort® 5110-T: 1-port RS-232 device server, -40 to 75°C operating temperature
Optional Accessories (can be purchased separately)
DK-35A: Mounting Kit for 35-mm DIN-Rail
8-22
NPort® 5150 (RS-232/422/485)
PIN
w w w. m o x a . c o m
[email protected]
Package Checklist
•
•
•
•
•
NPort® 5100 series device server
Power Adaptor (only for non-T models)
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
Industrial Networking Solutions
NPort® DE-211/311
1-port
p RS-232/422/485
/ /
serial device servers
› 3-in-1 serial port: RS-232, RS-422, or RS-485
› Versatile operation modes, including TCP Server, TCP Client,
UDP, Ethernet Modem, and Pair Connection
› Real COM/TTY drivers for Windows and Linux
› 10M and 100M Ethernet speeds detected automatically
› 2-wire RS-485 with patented Automatic Data Direction Control
(ADDC®)
› Built-in 15 KV ESD protection for all serial signals
NPort® DE-3
DE-311
NPort®
ort® DE-211
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
The NPort® DE-211 and DE-311 are 1-port serial device servers that
support RS-232, RS-422, 4-wire RS-485, and 2-wire RS-485. The
DE-211 supports 10 Mbps Ethernet connections and has a DB25
female connector for the serial port. The DE-311 supports 10/100
Mbps Ethernet connections and has a DB9 female connector for the
serial port.
Both device servers are ideal for applications that involve information
display boards, PLCs, flow meters, gas meters, CNC machines, and
biometric identification card readers.
Specifications
Ethernet Interface
Software
Number of Ports: 1
Speed:
NPort® DE-211: 10 Mbps, auto MDI/MDIX
NPort® DE-311: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Network Protocols: DHCP, BOOTP, Telnet, TCP, UDP, IP, ICMP, ARP
Configuration Options: Serial Console, Telnet Console, Windows
Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Serial Interface
Number of Ports: 1
Serial Standards: RS-232/422/485 (selectable by DIP Switch)
Connector:
NPort® DE-211: DB25 female
NPort® DE-311: DB9 female
Serial Line Protection: 15 KV ESD protection for all signals
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS, XON/XOFF
Baudrate: 50 bps to 230.4 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND (DE-211 only)
RS-485-2w: Data+, Data-, GND
Serial Device Servers > NPort® DE-211/311
Overview
8
Physical Characteristics
Housing: Metal, IP30 protection
Weight: 480 g
Dimensions:
Without ears: 67 x 100.4 x 22 mm (2.64 x 3.95 x 0.87 in)
With ears: 90.2 x 100.4 x 22 mm (3.55 x 3.95 x 0.87 in)
Environmental Limits
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements
Input Voltage:
DE-211: 12 to 30 VDC
DE-311: 9 to 30 VDC
Power Consumption:
NPort® DE-211: 180 mA @ 12 V, 100 mA @ 24 V
NPort® DE-311: 300 mA @ 9 V, 150 mA @ 24 V
[email protected]
w w w. m o x a . c o m
8-23
Serial-to-Ethernet Solutions
Regulatory Approvals
MTBF (meantime between failures):
NPort DE-211: 347822 hrs
NPort DE-311: 225529 hrs
EMC: CE (EN55022 Class B, EN55024 Class B), FCC Part 15
Subpart B
Safety: UL (UL60950), TÜV (EN60950)
Medical: EN60601-1-2 Class B, EN55011 (DE-311 only)
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions
ON
1 2
DIP
3
4
22.0 mm
(0.87 in)
NPort® DE-211
22.0 mm
(0.87 in)
NPort® DE-311
22.0 mm
(0.87 in)
22.0 mm
(0.87 in)
8
RESET 10/100M
Ethernet
DC-IN
SW
DC-IN
RESET 10BaseT
Ethernet
O 6 mm
(0.24 in)
PWR
PWR
O 4 mm
(0.16 in)
Link
O 6 mm
(0.24 in)
O 4 mm
(0.16 in)
Link
Ready
Ready
SW1
ON
21.3 mm
(0.8 in)
OFF
Serial
Connection SW2
Console
(19200,N,8,1)
SW3
OFF
OFF
RS-232
OFF
ON
ON
OFF
RS-422
RS-485 by RTS
ON
ON
RS-485 ADDC
Data
Comm.
Express
DE-211 RS-232/422/485 Device Server
Interface Mode
RS-232
Serial
O 7 mm
(0.28 in)
21.3 mm
(0.8 in)
SW1
Serial
Connection
ON
RS-232
Console
OFF
Data
Comm
SW2 SW3 SW4
12.5 mm
(0.49 in)
25 mm
(0.98 in)
100.4 mm
(3.95 in)
12.5 mm
(0.49 in)
25 mm
(0.98 in)
Express
DE-311 RS-232/422/485 Device Server
Serial Rx
Serial Interface Mode
OFF OFF
OFF
RS-232
OFF
ON
ON
RS-422
ON
OFF
ON
4-Wire RS-485 by RTS
ON
ON
ON
4-Wire RS-485 by ADDC
ON
OFF
OFF
2-Wire RS-485 by RTS
ON
ON
OFF
4-Wire RS-485 by ADDC
O 7 mm
(0.28 in)
Serial
SW
42.3 mm
(1.67 in)
ON
1 2 3
22.0 mm
(0.87 in)
42.3 mm
(1.67 in)
22.0 mm
(0.87 in)
Serial Device Servers > NPort® DE-211/311
100.4 mm
(3.95 in)
Serial Tx
67.0 mm
(2.64 in)
78 mm
(3.07 in)
67.0 mm
(2.64 in)
78 mm
(3.07 in)
90.2 mm
(3.55 in)
90.2 mm
(3.55 in)
Pin Assignment
NPort® DE-211
(RS-232/422/485, DB25 female connector)
NPort® DE-311
(RS-232/422/485, DB9 female connector)
13 Power GND for 12-30 VDC
12 Unreg. 12-30 VDC (in)
25
1 2 3 4 5
10 Power GND for 5 VDC
9 Reg. +5 VDC (out)
8 DCD (in)
7 SGND
6 DTR (out)
5 RTS (out)
4 CTS (in)
3 TxD (out)
2 RxD (in)
1 Do not use this pin*
RXDA(-) / DATAA(-)
RXDB(+) / DATAB(-)
DSR (IN) 20
TXDA (-) 15
TXDB (+) 14
PIN
1
2
3
4
5
6
7
8
9
6 7 8 9
RS-232
DCD
TxD
RxD
DSR
GND
DTR
CTS
RTS
----
RS-422/485-4w
RxD-(A)
RxD+(B)
TxD+(B)
TxD-(A)
GND
CTS-(A)
CTS+(B)
RTS+(B)
RTS-(A)
RS-485-2w
------Data+(B)
Data-(A)
GND
-------------
Ordering Information
Available Models
Package Checklist
NPort® DE-211: 1-port RS-232/422/485 device server with 10 Mbps Ethernet connection
NPort® DE-311: 1-port RS-232/422/485 device server with 10/100 Mbps Ethernet connection
Optional Accessories (can be purchased separately)
NP21101: DB25 male to DB9 female cable for RS-232 transmission, 30 cm (for DE-211)
NP21102: DB25 male to DB9 male cable for RS-232 transmission, 30 cm (for DE-211)
NP21103: DB25 male terminal block kit for RS-422/485 transmission (for DE-211)
TB-M25: DB25 male DIN-Rail wiring terminal (for DE-211)
TB-M9 (for DE-311): DB9 male DIN-Rail wiring terminal (for DE-311)
DK-35A: Mounting Kit for 35-mm DIN-Rail
8-24
w w w. m o x a . c o m
[email protected]
•
•
•
•
NPort® DE-211 or DE-311 serial device server
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
Industrial Networking Solutions
NPort® 5200 Series
2-port RS-232/422/485 serial device servers
› Small size for easy installation
› Versatile socket operation modes, including TCP Server, TCP
Client, and UDP
› Easy-to-use Windows utility for configuring multiple device
servers
› Supports 10/100M Ethernet
› Patented ADDC® (Automatic Data Direction Control) for 2-wire
and 4-wire RS-485
› Built-in 15 KV ESD protection for all serial signals
› SNMP MIB-II for network management
Standard TCP/IP Protocols and Choice of Operation Modes
NPort® 5200 device servers can operate in TCP Server, TCP Client, or
UDP operation mode, ensuring compatibility with software based on a
standard network API (Winsock, BSD Sockets).
Real COM/TTY Drivers for Existing Software
With the Real COM/TTY drivers that are provided with each NPort®,
software designed for communication with COM/TTY ports can be
instantly and seamlessly integrated into a TCP/IP network. This is an
excellent “no fuss” way to preserve your software investment and
enjoy the benefits of networking your serial devices.
Control Remote Serial Devices with TCP/IP or Traditional COM/TTY Port
By specifying the NPort® 5200’s IP address and port number, a
network sockets API can obtain access to the attached serial device
over the network, from any host computer that supports TCP/IP. For
Serial Device Servers > NPort® 5200 Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
8
legacy Windows or Linux software that is COM or TTY-based, Moxa’s
COM/TTY drivers provide a seamless way of operating over the
network.
COM Driver or Network Socket Operation
Remote Host
(Windows or Linux)
Internet
Local Host
(Windows or Linux)
Ethernet
192.168.10.2:4001
NPort® 5230/5232
2-wire RS-485
Up to 32 Serial Devices
[email protected]
w w w. m o x a . c o m
8-25
Serial-to-Ethernet Solutions
Appearance
NPort® 5232
Ethernet
RJ45 10/100 Mbps
Reset Button
NPort® 5230
NPort® 5210
Ethernet
RJ45 10/100 Mbps
Power Input
Terminal Block
12 to 48 VDC
Power Input
Terminal Block
12 to 48 VDC
Power Input
Terminal Block
12 to 48 VDC
Reset
Button
Reset Button
Ethernet
RJ45 10/100 Mbps
DK-35A DIN-Rail Kit
8
Available Accessory
Serial Device Servers > NPort® 5200 Series
DIN-Rail Kit
(Optional)
RS-422/485
RS-232
Specifications
8-pin RJ45, RS-232
Ethernet Interface
Software
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP
Configuration Options: Web Console, Serial Console (NPort®
5210/5230 only), Telnet Console, Windows Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Serial Interface
Number of Ports: 2
Serial Standards:
NPort® 5210: RS-232
NPort® 5230: 1 RS-232 port, 1 RS-422/485 port
NPort® 5232/5232I: RS-422/485
Connector:
NPort® 5210: RJ45 (8 pins)
NPort® 5230/5232/5232I: Terminal Block (5 contacts per port)
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort® 5232I/5232I-T)
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS (RS-232 only), DTR/DSR (NPort® 5210
only), XON/XOFF
Baudrate: 110 bps to 230.4 Kbps
Serial Signals
RS-232:
NPort® 5210: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
NPort® 5230: TxD, RxD, RTS, CTS, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
8-26
RS-422/485
w w w. m o x a . c o m
Physical Characteristics
Housing: Metal, IP30 protection
Weight:
NPort® 5210: 340 g
NPort® 5230/5232: 360 g
NPort® 5232I: 380 g
Dimensions:
NPort® 5210/5230/5232:
Without ears: 67 x 100.4 x 22 mm (2.64 x 3.95 x 0.87 in)
With ears: 90 x 100.4 x 22 mm (3.54 x 3.95 x 0.87 in)
NPort® 5232I:
Without ears: 67 x 100.4 x 35 mm (2.64 x 3.95 x 1.37 in)
With ears: 90 x 100.4 x 35 mm (3.54 x 3.95 x 1.37 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
[email protected]
Industrial Networking Solutions
Power Requirements
Reliability
Input Voltage: 12 to 48 VDC
Power Consumption:
NPort® 5210: 325 mA @ 12 V, 190 mA @ 24 V
NPort® 5230: 325 mA @ 12 V, 190 mA @ 24 V
NPort® 5232: 280 mA @ 12 V, 150 mA @ 24 V
NPort® 5232I: 509.4 mA @ 12 V, 200 mA @ 24 V
Alert Tools: Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
NPort® 5210: 134850 hrs
NPort® 5230: 106955 hrs
NPort® 5232: 102344 hrs
NPort® 5232I: 87083 hrs
Regulatory Approvals
Warranty
EMC: CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), TÜV (EN60950-1)
Marine: DNV
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions
NPort® 5210
8
NPort® 5230
22.0 mm
(0.87 in)
RESET
10/100M
Ethernet
V-
10/100M
Ethernet
RESET
Ready
O 4 mm
(0.16 in)
Link
P2
5230
5210
Industrial RS-232/422/485 Device Server
GND
R-/D-
T-
T+
P2 RS-485/422
GND
Tx
Rx
P1 RS-232
P2 RS-232
P1 RS-232
R+/D+
O 7 mm
(0.28 in)
21.3 mm
(0.8 in)
CTS
5210
Industrial RS-232 Device Server
12.5 mm
(0.49 in)
25 mm
(0.98 in)
P1
P2
(3.95 in)
P1
RTS
Link
100.4 mm
V+
12-48V
O 6 mm
(0.24 in)
Serial Device Servers > NPort® 5200 Series
V+
V-
12-48V
Ready
22.0 mm
(0.87 in)
42.3 mm
(1.67 in)
67 mm
(2.64 in)
78 mm
(3.07 in)
NPort® 5232I
90.2 mm
(3.55 in)
NPort® 5232
90 mm (3.54 in)
78 mm (3.07 in)
67 mm (2.64 in)
V+
V-
RESET
11.5 mm (0.45 in)
V+
V-
Link
RESET
12-48V
28.7 mm (1.13)
Ready
10/100M
Ethernet
P1
Ready
P2
Link
P1
5232
5210
5232I
5210
Ø4 mm
( 0.16 in)
Ø7 mm
( 0.28 in)
Ø6 mm
( 0.24 in)
GND
R-/D-
R+/D+
T-
P2 RS-485/422
GND
R-/D-
T+
T-
R+/D+
P1 RS-485/422
T+
GND
R-/D-
T+
T-
R+/D+
GND
R-/D-
T+
T-
P2 RS-485/422
R+/D+
Industrial RS-422/485 Device Server
100.4 mm (3.95 in)
43 mm (1.69 in)
25 mm (0.98 in)
P2
Industrial RS-422/485 Device Server
P1 RS-485/422
9 mm (0.35 in)
12-48V
10/100M
Ethernet
9 mm (0.35 in)
35 mm (1.38 in)
[email protected]
w w w. m o x a . c o m
8-27
Serial-to-Ethernet Solutions
Pin Assignment
NPort® 5210/5210-T (RS-232)
R+/D+
R-/D-
GND
GND
T+
Rx-
Tx- / Data-
GND
Rx+
Tx+ / Data+
R-/D-
GND
T-
R+/D+
Tx- / Data-
P2 RS-485/422
Tx+ / Data+
T-
GND
T+
Serial Device
Signals
Ordering Information
Available Models
Package Checklist
NPort® 5210: 2-port RS-232 device server, 0 to 55°C operating temperature
NPort® 5230: 2-port device server with 1 RS-232 port and 1 RS-422/485 port, 0 to 55°C
operating temperature
NPort® 5232: 2-port RS-422/485 device server, 0 to 55°C operating temperature
NPort® 5232I: 2-port RS-422/485 device server with 2 KV optical isolation, 0 to 55°C
operating temperature
NPort® 5210-T: 2-port RS-232 device server, -40 to 75°C operating temperature
NPort® 5230-T: 2-port device server with 1 RS-232 port and 1 RS-422/485 port, -40 to
75°C operating temperature
NPort® 5232-T: 2-port RS-422/485 device server, -40 to 75°C operating temperature
NPort® 5232I-T: 2-port RS-422/485 device server with 2 KV optical isolation, -40 to 75°C
operating temperature
•
•
•
•
•
Optional Accessories (can be purchased separately)
DK-35A: Mounting Kit for 35-mm DIN-Rail
DIN-Rail Power Supply: See page A-8 for details
Terminal Block: See page A-7 for details
8-28
P1 RS-485/422
NPort 5232/5232-T
NPort 5232I/5232I-T
Signals
GND
R-/D-
R+/D+
T+
GND
T-
Rx-
Rx+
CTS
RTS
P2 RS-485/422
GND
RTS
CTS
Tx
Rx
TxD
Serial Device Servers > NPort® 5200 Series
Serial Device
Signals
P1 RS-232
RxD
8
NPort 5230/5230-T
Signals
NPort® 5232/5232I/5232-T/5232I-T
(RS-422/485, terminal block connector)
Rx-
NPort® 5230/5230-T
(RS-232/422/485, terminal block connector)
Tx- / Data-
8
Tx+ / Data+
1
RS-232
DSR (in)
RTS (out)
GND
TxD (out)
RxD (in)
DCD (in)
CTS (in)
DTR (out)
Rx+
PIN
1
2
3
4
5
6
7
8
8-pin RJ45 connector
w w w. m o x a . c o m
[email protected]
NPort® 5200 series device server
Power jack to 3-pin terminal block adaptor
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
Industrial Networking Solutions
NPort® 5400 Series
4-port RS-232/422/485 serial device servers
› Easy IP address configuration with built-in LCD panel
› 10/100M auto-sensing Ethernet
› 4 serial ports, with support for RS-232, RS-422, and RS-485
› Built-in 15 KV ESD surge protection for all serial signals
› Versatile socket operation modes, including TCP Server, TCP
Client, and UDP
› Choice of configuration methods: Web console, Telnet console,
and Windows utility
› SNMP MIB-II for network management
› 2 KV isolation protection for NPort® 5430I/5450I
Network Readiness for up to Four Serial Devices
NPort® 5400 device servers can conveniently and transparently
connect up to four serial devices to an Ethernet network, allowing you
to network your existing serial devices with only basic configuration.
Data transmission between the serial and Ethernet interfaces is
bi-directional. By using NPort® device servers, you not only protect
your current hardware investment, but also allow for future network
expansion. You can both centralize the management of your serial
devices, and distribute management hosts over the network.
Independent Operation Mode for each Serial Port
NPort® 5400 device servers can be used to connect different devices
for remote data polling or event handling over a TCP/IP network. Each
serial port on the NPort® 5400 operates independently to provide
maximum versatility. For example, port 1 can operate in Driver mode,
port 2 in TCP Server mode, and ports 3 and 4 in TCP Client mode.
User-friendly LCD Panel for Easy Installation
Serial Device Servers > NPort® 5400 Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
8
An LCD panel is built into the NPort® 5400’s top panel, with four
buttons for inputting data, configuration, and selecting the operation
mode. The LCD panel displays the server name, serial number, and IP
address, and can be used to enter or modify parameters such as IP
address, netmask, and gateway.
Redundant DC Power Inputs
NPort® 5400 device servers support redundant power sources and
provide both a DC terminal block input and a DC power jack input. The
two power inputs not only provide power redundancy, but also allow
greater flexibility for use with different applications.
Adjustable Termination and pull High/Low Resistors
Termination resistors may be needed in some critical environments
to prevent the reflection of serial signals. When using termination
resistors, it is important to set the pull high/low resistors correctly
to prevent the electrical signal from being corrupted. Since no set of
resistor values is universally compatible with all environments, the
NPort® 5400 has four sets of DIP switches on the bottom panel to set
the termination and pull high/low resistor values.
[email protected]
w w w. m o x a . c o m
8-29
Serial-to-Ethernet Solutions
Appearance
NPort® 5410
Power Input
Power Jack
(1 to 48 VDC)
8
Power Input
Terminal Block
(12 to 48 VDC)
Reset Button
NPort® 5450/5450I
LEDs
LAN and Serial Status
LCD Panel
DK-35A DIN-Rail Kit
Serial Device Servers > NPort® 5400 Series
Available Accessory
Terminal
Block
DB9 male
DIN-Rail or Panel mounting
Optional DIN-Rail (35 mm)
Mounting Kit
DB9 male
Push Buttons
Specifications
Ethernet Interface
Software
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP, Rtelnet, ARP
Configuration Options: Web Console, Telnet Console, Windows
Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Serial Interface
Number of Ports: 4
Serial Standards:
NPort® 5410: RS-232
NPort® 5430/5430I: RS-422/485
NPort® 5450/5450I: RS-232/422/485
Connector:
NPort® 5410/5450/5450I: DB9 male
NPort® 5430/5430I: Terminal block
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort® 5430I/5450I)
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 120 Ω
Mini Screen with Push Buttons
LCD Panel: Liquid Crystal Display on the case
Push Buttons: Four push buttons for convenient on-site configuration
Physical Characteristics
Housing: Metal, IP30 protection
Weight: 740 g
Dimensions:
Without mounting kit: 158 x 103 x 33 mm (6.22 x 4.06 x 1.30 in)
With mounting kit: 176 x 103 x 33 mm (6.93 x 4.06 x 1.30 in)
Serial Communication Parameters
Environmental Limits
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 70°C (-4 to 158°F)
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
8-30
NPort® 5430/5430I
Ethernet
RJ45 10/100 Mbps
w w w. m o x a . c o m
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption:
NPort® 5410: 350 mA @ 12 V, 190 mA @ 24 V
NPort® 5430: 320 mA @ 12 V, 175 mA @ 24 V
NPort® 5430I: 530 mA @ 12 V, 280 mA @ 24 V
NPort® 5450: 350 mA @ 12 V, 190 mA @ 24 V
NPort® 5450I: 554 mA @ 12 V, 294 mA @ 24 V
[email protected]
Industrial Networking Solutions
Regulatory Approvals
MTBF (meantime between failures):
NPort® 5410: 205153 hrs
NPort® 5430: 201699 hrs
NPort® 5430I: 114540 hrs
NPort® 5450: 206903 hrs
NPort® 5450I: 206903 hrs
EMC: CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), TÜV (EN60950-1)
Marine: DNV
Medical: EN60601-1-2 Class B, EN55011
Warranty
Reliability
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Alert Tools: Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
Dimensions
O 3.2 mm
(0.13 in)
RESET
33 mm
(1.3 in)
4 Port Device Server
P4
P3
158 mm (6.22 in)
158 mm (6.22 in)
169 mm (6.67 in)
169 mm (6.67 in)
Serial Device
Signals
NPort® 5450/5450I (RS-232/422/485, DB9 male connector)
(RS-232/422/485, DB9 male connector)
1 2 3 4 5
6 7 8 9
PIN
1
2
3
4
5
6
7
8
GND
R- / D-
NPort 5430/5430I
Terminal Block
RS-232
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RS-422/RS-485-4w
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
-------
RS-485-2w
----Data+(B)
Data-(A)
GND
-------
GND
6 7 8 9
T-
1 2 3 4 5
NPort® 5430/5430I
(RS-422/485, terminal block connector)
RS-232
DCD
RxD
RxD
DTR
GND
DSR
TRS
CTS
---
T+
PIN
1
2
3
4
5
6
7
8
9
Rx-
NPort® 5410
(RS-232, DB9 male connector)
Rx+
Pin Assignment
Tx- / Data-
181 mm (7.14 in)
R+ / D+
P2
P1
Tx+ / Data+
39 mm 25 mm
(1.54 in) (0.98 in)
8
V+ V-
Serial Device Servers > NPort® 5400 Series
103 mm (4.06 in)
LAN
35.5 mm
(1.4 in )
5410
Ordering Information
Available Models
Package Checklist
NPort® 5410: 4-port RS-232 device server
NPort® 5430: 4-port RS-422/485 device server
NPort® 5430I: 4-port RS-422/485 device server with 2 KV optical isolation
NPort® 5450: 4-port RS-232/422/485 device server
NPort® 5450I: 4-port RS-232/422/485 device server with 2 KV optical isolation
•
•
•
•
NPort® 5400 series device server
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
Optional Accessories (can be purchased separately)
DK-35A: Mounting Kit for 35-mm DIN-Rail
DIN-Rail Power Supply: See page A-8 for details
Terminla Block: See page A-7 for details
Power Adaptor: See page A-9 for details
[email protected]
w w w. m o x a . c o m
8-31
Serial-to-Ethernet Solutions
NPort® 5600 Rackmount Series
8 and 16-port RS-232/422/485 serial device servers
› 8 or 16 serial ports supporting RS-232/422/485
› Standard 19-inch rackmount size
› 10/100M auto-sensing Ethernet
› Built-in 15 KV ESD protection for all serial signals
› Easy IP address configuration with LCD panel
› Choice of configuration methods: Web console, Telnet console,
and Windows utility
› Versatile socket operation modes, including TCP Server, TCP
Client, UDP, and Real COM
› SNMP MIB-II for network management
8
Serial Device Servers > NPort® 5600 Rackmount Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Overview
With the NPort® 5600 rackmount series, you not only protect your
current hardware investment, but also allow for future network
expansion by centralizing the management of your serial devices and
distributing management hosts over the network.
and reception, the NPort® drivers also support the RTS, CTS, DTR,
DSR, and DCD control signals.
LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located
on the RJ45 connector) provide a great tool for basic maintenance
tasks, and help engineers analyze problems in the field. The LEDs not
only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
Network Readiness for up to 16 Serial Devices
Only basic configuration is needed with the NPort® 5600 to connect
up to 16 serial devices to an Ethernet network.
19-inch Rackmount Device Server
Adjustable Termination and Pull High/Low Resistors
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports
on the front panel, and 8 or 16 RJ45 serial port connectors on the
rear panel. This makes the NPort® 5600 device servers suitable for
standard 19-inch rack mounting, allowing you to simplify operation,
maintenance, and administrative tasks.
When using termination resistors to prevent serial signal reflection,
it is important to set the pull high/low resistors correctly so that the
electrical signal is not corrupted. Since no set of resistor values is
universally compatible for all environments, the NPort® 5600 has DIP
switches on the bottom panel for setting the termination and pull high/
low resistor values.
Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the
NPort® 5600 recognizable as Real COM ports by Windows, or Real
TTY ports by Linux. In addition to supporting basic data transmission
Appearance
AC Power Input
100 to 240 VAC Input, 47 to 63 HZ
AC Power Switch
Ethernet RJ45 10/100 Mbps
Serial Ports (50 bps to 921.6 Kbps, RJ45 connectors)
NPort® 5610: RS-232
NPort® 5630: RS-422/485
NPort® 5650: RS-232/422/485
Connection Cable
RJ45 to DB9 Cable
(Optional Accessory)
Push Buttons
Mounting Plate
8-32
LCD Panel
w w w. m o x a . c o m
Reset Button
[email protected]
LED Indicators
System Status, Serial Tx/Rx
Industrial Networking Solutions
Specifications
Ethernet Interface
Physical Characteristics
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Housing: Metal, IP30 protection
Weight:
NPort® 5610-8: 3340 g
NPort® 5610-8-48V: 3160 g
NPort® 5630-8, 5650-8-S-SC, 5650-8-M-SC: 3380 g
NPort® 5650-8: 3360 g
NPort® 5610-16: 3420 g
NPort® 5610-16-48V: 3260 g
NPort® 5630-16: 3400 g
NPort® 5650-16: 3460 g
NPort® 5650-16-S-SC, 5650-16-M-SC: 3440 g
Dimensions:
Without ears: 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
With ears: 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
Optical Fiber Interface
Distance:
Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
Min. TX Output: -20 dBm (Multi mode), -5 dBm (Single mode)
Max. TX Output: -14 dBm (Multi mode), 0 dBm (Single mode)
Sensitivity: -34 to -30 dBm (Multi mode), -36 to -32 dBm (Single
mode)
Serial Interface
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 75°C (-4 to 167°F)
Power Requirements
Input Voltage:
NPort® 5610/5630/5650: 100 to 240 VAC, 47 to 63 hz
NPort® 5610-48V: ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
Power Consumption:
NPort® 5610-8/16: 141 mA @ 100 VAC, 93 mA @ 240 VAC
NPort® 5630-8/16: 152 mA @ 100 VAC, 98 mA @ 240 VAC
NPort® 5610-8/16-48V: 135 mA @ 48 VDC
NPort® 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort® 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC
NPort® 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
NPort® 5610 only: IEC61000-4-12
Safety: UL (UL60950-1), TÜV (EN60950-1)
Medical: EN60601-1-2 Class B, EN55011
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Reliability
Software
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet,
RFC2217
Configuration Options: Web Console, Telnet Console, Windows
Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Mini Screen with Push Buttons
LCD Panel: Liquid Crystal Display on the case
Push Buttons: Four push buttons for convenient on-site configuration
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
NPort® 5610-8: 97294 hrs
NPort® 5610-16: 94928 hrs
NPort® 5610-8-48V: 96758
NPort® 5610-16-48V: 94417 hrs
NPort® 5630-8: 118405 hrs
NPort® 5630-16: 91483 hrs
NPort® 5650-8: 117584 hrs
NPort® 5650-16: 104767 hrs
NPort® 5650-S-SC-8: 116914 hrs
NPort® 5650-S-SC-16: 87528 hrs
NPort® 5650-M-SC-8: 116914 hrs
NPort® 5650-M-SC-16: 87528 hrs
8
Serial Device Servers > NPort® 5600 Rackmount Series
Number of Ports: 8 or 16
Serial Standards:
NPort® 5610: RS-232
NPort® 5630: RS-422/485
NPort® 5650: RS-232/422/485
Connector: RJ45 (8 pins)
Serial Line Protection:
15 KV ESD protection for all signals
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Environmental Limits
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
[email protected]
w w w. m o x a . c o m
8-33
Serial-to-Ethernet Solutions
Dimensions
198 mm (7.8 in)
5610-16
Serial ports
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
45 mm
(1.77 in)
8
16
LA N
Serial Device Servers > NPort® 5600 Rackmount Series
AC POWER 100-240V,47-63Hz
440 mm (17.3 in)
480 mm (19 in)
Pin Assignment
(8-pin RJ45 connector)
1
NPort® 5610: RS-232
NPort® 5630: RS-422/485
NPort® 5650: RS-232/422/485
PIN
RS-232
PIN
RS-422/485-4w
RS-485-2w
PIN
RS-232
RS-422/485-4w
RS-485-2w
1
DSR
1
---
---
1
DSR
---
---
2
RTS
2
---
---
2
RTS
TxD+
---
3
GND
3
TxD+
---
3
GND
GND
GND
4
TXD
4
TxD-
---
4
TXD
TxD-
---
5
RxD
5
RxD-
Data+
5
RxD
RxD+
Data+
6
DCD
6
RxD+
Data-
6
DCD
RxD-
Data-
7
CTS
7
GND
GND
7
CTS
---
---
8
DTR
8
---
---
8
DTR
---
---
8
Ordering Information
Available Models
NPort® 5610-8: 8-port RS-232 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5610-8-48V: 8-port RS-232 rackmount device server with RJ45 connectors and 48 VDC power input
NPort® 5630-8: 8-port RS-422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5650-8: 8-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5650-8-M-SC: 8-port RS-232/422/485 rackmount device server with RJ45 connectors and 100BaseF(X) multi-mode fiber (SC connector)
NPort® 5650-8-S-SC: 8-port RS-232/422/485 rackmount device server with RJ45 connectors and 100BaseF(X) single-mode fiber (SC connector)
NPort® 5610-16: 16-port RS-232 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5610-16-48V: 16-port RS-232 rackmount device server with RJ45 connectors and 48 VDC power input
NPort® 5630-16: 16-port RS-422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5650-16: 16-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort® 5650-16-M-SC: 16-port RS-232/422/485 rackmount device server with RJ45 connectors and 100BaseF(X) multi-mode fiber (SC connector)
NPort® 5650-16-S-SC: 16-port RS-232/422/485 rackmount device server with RJ45 connectors and 100BaseF(X) single-mode fiber (SC connector)
8-34
Optional Accessories (can be purchased separately)
Package Checklist
CBL-RJ45F25-150: 8-pin RJ45 to DB25 female cable, 150 cm
CBL-RJ45M25-150: 8-pin RJ45 to DB25 male cable, 150 cm
CBL-RJ45F9-150: 8- pin RJ45 to DB9 female cable, 150 cm
CBL-RJ45M9-150: 8-pin RJ45 to DB9 male cable, 150 cm
•
•
•
•
•
w w w. m o x a . c o m
[email protected]
NPort® 5600 series device server
Power Cord (see Appendix A)
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
Industrial Networking Solutions
NPort® 5600 Desktop Series
8-port RS-232/422/485 serial device servers
› 8 serial ports supporting RS-232/422/485
› Compact desktop design
› 10/100M auto-detecting Ethernet
› Built-in 15 KV ESD protection for all serial signals
› Easy IP address configuration with LCD panel
› Choice of configuration methods: Web console, Telnet console, and
Windows utility
› Versatile socket operation modes, including TCP Server, TCP
Client, UDP, and Real COM
› SNMP MIB-II for network management
› Built-in speaker: Use your own voice as the alert when exceptions
8
occur
Overview
NPort® 5600-8-DT device servers can conveniently and transparently
connect 8 serial devices to an Ethernet network, allowing you to
network your existing serial devices with only basic configuration. You
can both centralize management of your serial devices and distribute
management hosts over the network. Since the NPort® 5600-8-DT
device servers have a smaller form factor compared to our 19-inch
models, they are a great choice for applications that need additional
serial ports, but for which mounting rails are not available.
Convenient Design for RS-485 Applications
The NPort® 5650-8-DT device servers support selectable 1 KΩ and
150 KΩ pull high/low resistors and a 120 Ω terminator. In some
critical environments, termination resistors may be needed to prevent
the reflection of serial signals. When using termination resistors, it
is also important to set the pull high/low resistors correctly so that
the electrical signal is not corrupted. Since no set of resistor values
is universally compatible with all environments, NPort® 5600-8-DT
device servers use DIP switches to allow users to adjust termination
and pull high/low resistor values manually for each serial port.
Convenient Power Inputs
LED Indicators to Ease Your Maintenance Tasks
The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the
RJ45 connector) provide a great tool for basic maintenance tasks and
help engineers analyze problems in the field. The NPort® 5600’s LEDs
not only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
Two Ethernet Ports for Convenient Cascade Wiring
The NPort® 5600-8-DT device servers come with two Ethernet ports
that can be used as Ethernet switch ports. Connect one port to the
network or server, and the other port to another Ethernet device. The
dual Ethernet ports eliminate the need to connect each device to a
separate Ethernet switch, reducing wiring costs.
Serial Device Servers > NPort® 5600 Desktop Series
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Automatic Warning Function by Speaker and/or E-mail
The built-in speakers can be used to alert administrators of problems
with the Ethernet links or power input. The web console indicates
which Ethernet link or power input has failed. An e-mail warning can
also be issued when an exception is detected. These functions are
valuable tools that enable maintenance engineers to react promptly to
emergency situations.
The NPort® 5650-8-DT device servers support both power terminal
blocks and power jacks for ease of use and greater flexibility. Users
can connect the terminal block directly to a DC power source, or use
the power jack to connect to an AC circuit through an adaptor.
[email protected]
w w w. m o x a . c o m
8-35
Serial-to-Ethernet Solutions
Appearance
LCD Panel
LED Indicators
Push Buttons
Ethernet Switch
RJ45 10/100 Mbps
8
Power Input
Both power Jack and
Terminal block 12-48VDC
Reset Button
RS-232 Console Port
Serial Device Servers > NPort® 5600 Desktop Series
Specifications
Ethernet Interface
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Number of Ports: 2
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Mini Screen with Push Buttons
Serial Interface
Number of Ports: 8
Serial Standards:
NPort® 5610-8-DT: RS-232
NPort® 5650-8-DT: RS-232/422/485
Connector:
NPort® 5610-8-DT/5650-8-DT/5650I-8-DT: DB9 male
NPort® 5610-8-DT-J/5650-8-DT-J: RJ45 (8 pins)
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort® 5650I-8-DT only)
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 120 Ω
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Software
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
DNS, SNMP V1/V2c, HTTP, SMTP, SNTP, Rtelnet, ARP, RFC2217
Configuration Options: Web Console, Telnet Console, Serial Console,
Windows Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
8-36
Serial Ports
NPort® 5610-8-DT: DB9, RS-232
NPort® 5650-8-DT: DB9, RS-232/422/485
NPort® 5610-8-DT-J: RJ45, RS-232
NPort® 5650-8-DT-J: RJ45, RS-232/422/485
w w w. m o x a . c o m
LCD Panel: Liquid Crystal Display on the case
Push Buttons: Four push buttons for convenient on-site configuration
Physical Characteristics
Housing: Metal, IP30 protection
Weight:
NPort® 5610-8-DT: 1760 g
NPort® 5610-8-DT-J: 1170 g
NPort® 5650-8-DT: 1770 g
NPort® 5650-8-DT-J: 1710 g
NPort® 5650I-8-DT: 1850 g
Dimensions:
Without ears: 197 x 44 x 135.5 mm (7.76 x 1.73 x 5.33 in)
With ears: 229 x 46 x 135.5 mm (9.01 x 1.81 x 5.33 in)
With DIN-Rail kit on bottom panel: 197 x 53 x 135.5 mm (7.76 x 2.09
x 5.33 in)
Environmental Limits
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 70°C (-4 to 158°F)
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption:
NPort® 5610-8-DT:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort® 5610-8-DT-J:
611 mA @ 12 V, 300 mA @ 24 V, 140 mA @ 48 V
NPort® 5650-8-DT:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
NPort® 5650I-8-DT:
1066 mA @ 12 V, 510 mA @ 24 V, 200 mA @ 48 V
NPort® 5650-8-DT-J:
615 mA @ 12 V, 300 mA @ 24 V, 156 mA @ 48 V
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), TÜV (EN60950-1)
[email protected]
Industrial Networking Solutions
Reliability
Warranty
Alert Tools: Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures): 163356 hrs
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions
44 mm
125 mm
25 mm
50 mm
5650-B-DT
Pin Assignment
DB9 male connector
1 2 3 4 5
6 7 8 9
8-pin RJ45 connector
1
8
NPort® 5610-8-DT (RS-232)
NPort® 5650-8-DT/5650I-8-DT (RS-232/422/485)
PIN
RS-232
PIN
RS-232
RS-422/485-4w
RS-485-2w
1
DCD
1
DCD
TxD-(A)
–
2
RxD
2
RxD
TxD+(B)
–
3
TxD
3
TxD
RxD+(B)
Data+(B)
4
DTR
4
DTR
RxD-(A)
Data-(A)
5
GND
5
GND
GND
GND
6
DSR
6
DSR
–
–
7
RTS
7
RTS
–
–
8
CTS
8
CTS
–
–
NPort® 5610-8-DT-J (RS-232)
PIN
RS-232
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
NPort® 5650-8-DT-J (RS-232/422/485)
PIN
1
2
3
4
5
6
7
8
RS-232
DSR
RTS
GND
TXD
RxD
DCD
CTS
DTR
RS-422/485-4w
--TxD+
GND
TxDRxD+
RxD-----
RS-485-2w
----GND
--Data+
Data-----
Serial Device Servers > NPort® 5600 Desktop Series
197 mm
209 mm
229 mm
8
Ordering Information
Available Models
NPort® 5610-8-DT: 8-port RS-232 desktop device server with DB9 male connectors and 48 VDC power input
NPort® 5610-8-DT-J: 8-port RS-232 desktop device server with RJ45 connectors and 48 VDC power input
NPort® 5650-8-DT: 8-port RS-232/422/485 desktop device server with DB9 male connectors and 48 VDC power input
NPort® 5650-8-DT-J: 8-port RS-232/422/485 desktop device server with RJ45 connectors and 48 VDC power input
NPort® 5650I-8-DT: 8-port RS-232/422/485 desktop device server with DB9 male connectors, 48 VDC power input, and 2 KV optical isolation
Optional Accessories (can be purchased separately)
Package Checklist
CBL-RJ45F25-150: 8-pin RJ45 to DB25 female cable, 150 cm
CBL-RJ45M25-150: 8-pin RJ45 to DB25 male cable, 150 cm
CBL-RJ45F9-150: 8-pin RJ45 to DB9 female cable, 150 cm
CBL-RJ45M9-150: 8-pin RJ45 to DB9 male cable, 150 cm
•
•
•
•
•
[email protected]
NPort® 5600 series device server
Power Adaptor (see Appendix A)
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
w w w. m o x a . c o m
8-37
Serial-to-Ethernet Solutions
NPort® IA5000 Series
1 and 2-port serial device servers for industrial automation
› Versatile socket operation modes, including TCP Server, TCP
Client, UDP
› Patented ADDC® (automatic data direction control) for 2-wire
and 4-wire RS-485
› Cascading Ethernet ports for easy wiring (applies only to RJ45
connectors)
› Redundant DC power inputs
› Warning by relay output and e-mail
› 10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode
with SC connector)
› IP30-rated housing
8
Serial Device Servers > NPort® IA5000 Series
The certification logos shown here apply to some or all of the
products in this section. For details, see “Regulatory Approvals”
under “Specifications” below.
Overview
NPort® IA device servers provide easy and reliable serial-to-Ethernet
connectivity for industrial automation applications. The device servers
can connect any serial device to an Ethernet network, and to ensure
compatibility with network software, they support a variety of port
operation modes, including TCP Server, TCP Client, and UDP. The
rock-solid reliability of the NPort® IA device servers makes them
an ideal choice for establishing network access to RS-232/422/485
serial devices such as PLCs, sensors, meters, motors, drives, barcode
readers, and operator displays. All models are housed in a compact,
rugged housing that is DIN-rail mountable.
Cascading Ethernet Ports Make Wiring Easy (10/100BaseTX models only)
The NPort® IA5150 and IA5250 device servers each have two Ethernet
ports that can be used as Ethernet switch ports. One port connects
directly to the network or server, and the other port can be connected
8-38
w w w. m o x a . c o m
to another NPort® IA device server or another Ethernet device. The
dual Ethernet ports help reduce wiring costs by eliminating the need to
connect each device to a separate Ethernet switch.
[email protected]
Industrial Networking Solutions
Redundant Power Inputs
The NPort® IA5000 device servers have two power inputs that can
be connected simultaneously to live DC power sources. If one power
source fails, the other source takes over automatically. Redundant
power inputs help assure non-stop operation of your device server.
Dual Power Inputs
Relay Output Warning and E-mail Alerts
The built-in relay output can be used to alert administrators of
problems with the Ethernet links or power inputs, or when there is a
change in the DCD or DSR serial signals. The web console indicates
Optical Fiber for Ethernet Communication
The NPort® IA5000 series includes 100BaseFX fiber models that
support transmission distances up to 2 km for multi-mode models,
and up to 40 km for single-mode models. Optical fiber is well-suited
for industrial applications because it is immune to electromagnetic
noise and interference. For environments that experience high ground
loop voltages, fiber provides the best isolation protection, and because
there is no danger of sparking, optical fiber is safer than copper wire to
use in hazardous environments.
8
Serial Device Servers > NPort® IA5000 Series
Power Failure Alarm
which Ethernet link or power input has failed, or which serial signal
has changed. An e-mail warning can also be issued when an exception
is detected. These functions are valuable tools that enable maintenance
engineers to react promptly to emergency situations.
Industrial-grade Certification
To ensure safe and reliable operation in industrial environments,
the NPort® IA5000 device servers have obtained various industrial
certifications, including an IP30 rating for mechanical protection,
UL508 safety certification for industrial control equipment, and
explosion-safe certifications for hazardous locations.
Certifications include UL/cUL Class 1 Division 2 Groups A,
B, C, D, and ATEX Class 1 Zone 2.
Appearance
Dual Power Input and
Relay Output
Reset
Reset
LED
Indicators
RS-422/485
RS-232
1-port
Copper
Ethernet
Fiber optic
Ethernet
RS-232/422/485
2-port
[email protected]
w w w. m o x a . c o m
8-39
Serial-to-Ethernet Solutions
Specifications
Ethernet Interface (NPort® IA5150/5150I/5250)
Environmental Limits
Number of Ports: 2
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Optical Fiber Interface (-M-SC and -S-SC models)
8
Fiber Port: 100 BaseFX, SC connector
Distance:
Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
Min. TX Output: -20 dBm (Multi mode), -5 dBm (Single mode)
Max. TX Output: -14 dBm (Multi mode), 0 dBm (Single mode)
Sensitivity: -34 to -30 dBm (Multi mode), -36 to -32 dBm (Single
mode)
Serial Interface
Serial Device Servers > NPort® IA5000 Series
Number of Ports:
NPort® IA5150: 1
NPort® IA5250: 2
Serial Standards: RS-232/422/485
Connector:
NPort® IA5150: DB9 male for RS-232, terminal block for RS422/485
NPort® IA5250: DB9 male for RS-232/422/485
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort® IA5150I, NPort® 5150I-M-SC,
NPort® 5150I-S-SC)
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF
Baudrate: 110 bps to 230.4 Kbps
Serial Signals
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption:
NPort® IA5150: 360 mA @ 12 V, 195 mA @ 24 V
NPort® IA5150I: 420 mA @ 12 V, 215 mA @ 24 V
NPort® IA5250: 440 mA @ 12 V, 200 mA @ 24 V
NPort® IA5150-S-SC: 470 mA @ 12 V, 210 mA @ 24 V
NPort® IA5150I-S-SC: 490 mA @ 12 V, 250 mA @ 24 V
NPort® IA5150-M-SC: 500 mA @ 12 V, 250 mA @ 24 V
NPort® IA5150I-M-SC: 510 mA @ 12 V, 260 mA @ 24 V
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
Safety: UL (UL60950-1), UL508, TÜV (EN60950-1)
Hazardous Location: UL/cUL Class 1 Division 2 Groups A, B, C and
D
ATEX: Class I, Zone 2
Marine: DNV
EMS:
EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12
Shock: IEC60068-2-27
Freefall: IEC60068-2-32
Vibration: IEC60068-2-6
Dust-proof: IP30
Reliability
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Software
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
Rtelnet, DNS, SNMP V1/V2c, HTTP, SMTP, SNTP
Configuration Options: Web Console, Serial Console, Telnet Console,
Windows Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Alert Tools: Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
NPort IA5150 Series: 183747 hrs
NPort IA5150I Series: 195614 hrs
NPort IA5250 Series: 194765 hrs
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Pin Assignment
PIN
1
2
3
4
5
6
7
8
RS-232/422/485
DB9 male port
1 2 3 4 5
Physical Characteristics
Housing: Plastic, IP30 protection
Weight:
NPort® IA5150: 360 g
NPort® IA5250: 380 g
Dimensions: 29 x 89.2 x 118.5 mm (0.82 x 3.51 x 4.57 in)
6 7 8 9
RS-422/485 Terminal
Block Wiring
5
8-40
w w w. m o x a . c o m
[email protected]
4
3
2
1
RS-232
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
PIN
1
2
3
4
5
RS-422/RS-485-4w
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
–
–
–
RS-485-2W
–
–
Data+(B)
Data-(A)
GND
–
–
–
RS-422/RS-485-4w
TxD+(B)
TxD-(A)
RxD+(B)
RxD-(A)
GND
RS-485-2w
–
–
Data+(B)
Data-(A)
GND
Industrial Networking Solutions
Dimensions
20.6 mm 29.91 mm
(0.81 in) (1.18 in)
NPort IA5150I-S-SC
NPort IA5150
NPort IA5150I-M-SC
NPort IA5150I
NPort IA5150-S-SC
NPort IA5250
NPort IA5150-M-SC
29 mm (1.14 in)
29 mm (1.14 in)
118.5 mm (4.67 in)
66.6 mm (2.62 in)
79.5 mm (3.13 in)
92.4 mm (3.64 in)
69.5 mm (2.74 in)
20 mm
(0.79 in)
NPort IA5150
NPort IA5150 I
NPort IA5150-S-SC
NPort IA5150-M-SC
NPort IA5150 I -S-SC
NPort IA5150 I -M-SC
89.2 mm (3.51 in)
NPort IA5250
25.9 mm
(1.02 in)
35 mm
(1.38 in)
Ordering Information
Available Models
NPort® IA5150: 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), 0 to 55°C operating temperature
NPort® IA5150I: 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP) and 2 KV optical isolation,
0 to 55°C operating temperature
NPort® IA5150-M-SC: 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors), 0 to 55°C operating
temperature
NPort® IA5150I-M-SC: 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical isolation,
0 to 55°C operating temperature
NPort® IA5150-S-SC: 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors), 0 to 55°C operating
temperature
NPort® IA5150I-S-SC: 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical isolation,
0 to 55°C operating temperature
NPort® IA5250: 2-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), 0 to 55°C operating temperature
NPort® IA5150-T: 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), -40 to 75°C operating
temperature
NPort® IA5150I-T: 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP) and 2 KV optical isolation,
-40 to 75°C operating temperature
NPort® IA5150-M-SC-T: 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors), -40 to 75°C operating
temperature
NPort® IA5150I-M-SC-T: 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical
isolation, -40 to 75°C operating temperature
NPort® IA5150-S-SC-T: 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors), -40 to 75°C operating
temperature
NPort® IA5150I-S-SC-T: 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical
isolation, -40 to 75°C operating temperature
NPort® IA5250-T: 2-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), -40 to 75°C operating
temperature
Optional Accessories (can be purchased separately)
Optical Fiber Patch Cord: See page A-14
Terminal Block for RS-422/485 ports: See page A-7
Power Jack to Terminal Block Cable: See page A-7
[email protected]
8
Serial Device Servers > NPort® IA5000 Series
35 mm
(1.38 in)
14.5 mm
(0.57 in)
14.5 mm
(0.57 in)
124.5 mm (4.9 in)
14.5 mm
(0.57 in)
25.9 mm
(1.02 in)
11.5 mm
(0.45 in)
Package Checklist
•
•
•
•
NPort IA series device server
Document and Software CD
Quick Installation Guide (printed)
Warranty Card
w w w. m o x a . c o m
8-41
on
Co
m
in
g
So
Serial-to-Ethernet Solutions
MiiNePort E1 Series
10/100 Mbps embedded serial device servers
› Same size as an RJ45 connector—only 33.9 x 16.25 x 13.5 mm
› Extremely low power consumption—only 160 mA @ 3.3 VDC input
› Uses the MiiNe, Moxa’s second generation SoC
› NetEZ technology makes integration incredibly easy
› Versatile choice of operation modes: Real COM, RFC2217, TCP
Server, TCP Client, UDP, and Modem
8
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Serial Device Servers > MiiNePort E1 Series
Overview
Moxa’s MiiNePort E1 embedded device servers are designed for
manufacturers who want to add sophisticated network connectivity
to their serial devices with minimal integration effort. The MiiNePort
E1 is empowered by the MiiNe, Moxa’s second generation SoC, which
supports 10/100 Mbps Ethernet, up to 921.6 Kbps serial baudrate,
a versatile selection of ready-to-use operation modes, and requires
only a small amount of power. By using Moxa’s innovative NetEZ
technology, the MiiNePort E1 can be used to convert any device with
a standard serial interface to an Ethernet enabled device in no time. In
addition, the MiiNePort E1 is the size of an RJ45 connector, making it
easy to fit into virtually any existing serial device.
The MiiNe—Moxa’s 2nd Generation SoC
The MiiNe was created to provide manufacturers with a competitive
embedded serial-to-Ethernet solution. The MiiNePort E1, which uses
the MiiNe for its SoC, is one of the world’s tiniest embedded device
servers, and has the lowest power consumption of any similar product.
The MiiNe has the following features:
•
•
•
•
Designed for 1 or 2-port serial-to-Ethernet applications
Uses a 32-bit ARM 7 core
Uses Moxa’s own advanced UART technology
Has 2 MB Flash and 4 MB SDRAM memory built in
NetEZ Technology
Moxa’s NetEZ technology gives serial device manufacturers a range of
powerful tools for integrating Ethernet capability into serial devices:
• SCM: The MiiNePort E1’s Serial Command Mode (SCM) enables
the device’s main system to reset the network and configure both
serial and Ethernet settings. This is done using simple command
frame format, and provides the convenience of being able to easily
configure the network settings at anytime.
8-42
w w w. m o x a . c o m
• AutoCFG: The MiiNePort E1 supports AutoCFG, which provides an
effortless way of configuring network settings of many devices
during mass production.
[email protected]
Industrial Networking Solutions
• MCSC: In some special circumstances, device end-users need the
device to be in Server mode and Client mode at the same time,
which requires that the embedded device server support
multi-channel communication. The MiiNePort E1’s Multi-Channel
Serial Communication (MCSC) feature uses a clever software
solution to provide the device with multi-channel functionality.
Moxa’s NetEZ technology makes the MiiNePort E1 the world’s most
user-friendly embedded device server by promising ease-of-use with
minimal integration work required.
MiiNePort E1 Starter Kit
Null Modem Cable
Power Cord
(US or Euro plug)
Cross-over
Ethernet Cable
Power Adaptor
(90 to 240 VAC,
12 VDC)
Document &
Software CD
Evaluation Board
Dimensions
(0
.0
4
in)
Recommended PC Board Layout
m
m
4 mm
(0.16 in)
1.5 mm
(0.06 in)
1.5 mm
(0.06 in)
13.5 mm
(0.53 in)
1.27 mm (0.05 in)
2.54 mm (0.1 in)
3.58 mm (0.14 in)
1.5 mm
(0.06 in)
in)
0.04
m (ø
m
ø1.1
33.9 mm (1.33 in)
24.1 mm (0.95 in)
13.5 mm (0.53 in)
14.52 mm (0.57 in)
in)
0.06
m (ø
m
ø1.6
2-
m
.9 m
.04
(ø0
in)
0
8-ø
10.84 mm
(0.43 in)
in)
0.13
m (ø
m
5
3.2
2-ø
6.35 mm (0.25 in)
2.54 mm (0.1 in)
11.8 mm (0.47 in)
10.84 mm 33.9 mm (1.33 in)
(0.43 in)
12.3 mm
(0.48in)
4.85 mm (0.19 in)
1.27 mm (0.05 in)
2.54 mm (0.1 in)
3.3 mm (0.13 in)
10.84 mm
(0.43 in)
17.19 mm (0.68 in)
19.73 mm (0.78 in)
22.74 mm (0.9 in)
32.4 mm (1.28 in)
16.25 mm (0.64 in)
18.22 mm (0.72 in)
16.25 mm (0.64 in)
1.5 mm (0.06 in)
ø1
24.54 mm (0.97 in)
8
Serial Device Servers > MiiNePort E1 Series
The MiiNePort E1 Starter Kit includes the MiiNePort E1 module, an
evaluation board, power adaptor, software, and serial and Ethernet
cables to allow quick and easy evaluation of all embedded device
server functions. The evaluation board is equipped with serial,
Ethernet, digital I/O, and power circuits to help you test your
MiiNePort E1 modules and applications.
12.3 mm
(0.48 in)
16.05 mm (0.63 in)
ø0.9 mm (ø0.04 in)
ø3.25 mm (ø0.13 in)
Pin Assignment
Pin
Function
Pin
Function
1
GND
5
Data In
2
VCC
6
Ready/RTSa
3
Reset
7
DIOb
4
Data Out
8
CTSc
a. Pin 6 can be configured as Ready/RTS (Request to Send), Ready/DO, or
RS-485 Tx Enabled (default is Ready/RTS)
b. Pin 7 can be configured as DIO, Modem Control Out, RS-485 Tx Enable, or
Reset to Default (default is DIO)
c. Pin 8 can be configured as CTS (Clear to Send), DI, or Modem Control In
(default is CTS)
[email protected]
w w w. m o x a . c o m
8-43
Serial-to-Ethernet Solutions
Specifications
Form Factor
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7, SVR
4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Operation Modes: TCP Server, TCP Client, UDP, Real COM mode,
Modem Mode, RFC2217
Type: Drop-in module
Dimensions: 33.9 x 16.25 x 13.5 mm (13.35 x 6.4 x 5.31 in)
Weight: 9 g
System Information
CPU: 32-bit ARM 7 Core
RAM: 4 MB built in
Flash: 2 MB built in
Environmental Limits
Ethernet Interface
8
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: RJ45 (with magnetics)
Magnetic Isolation Protection: 1.5 KV built-in
LEDs: 10BASE-T & 100BASE-TX Link Activity, Fault/In-Use
Power Requirements
Serial Device Servers > MiiNePort E1 Series
Serial Interface
Input Voltage: 3.3 VDC (±5%)
Power Consumption: 160 mA @ 3.3 VDC max.
Number of Ports: 1
Transmission Format: Standard TTL
Regulatory Approvals
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS, XON/XOFF
Baudrate: 50 bps to 230.4 Kbps* (supports non-standard baudrates)
* Baudrates up to 921.6 Kbps available by request
Serial Signals
TTL: TxD, RxD, RTS, CTS, RST (reset circuit), GND
Digital I/O Pins
EMC:
• Radiated & conducted emissions: Complies with Class B limits of
EN55022:1998
• Direct & Indirect ESD: Complies with EN55024:1998
• Electrical Fast Transient/Burst Immunity: Complies with
EN55024:1998
• Power Frequency Magnetic Field Immunity: Complies with
EN55024:1998
Shock: 500 g’s for non-operational shock
Vibration: 20 g’s for non-operational vibration
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
Warranty
GPIO: 3 programmable I/O pins (1 DO, 1 DI, 1 DI/O)
Software
Network Protocols: ICMP, ARP, IP, TCP, UDP, DHCP, HTTP, SNMP
V1/V2c, SMTP, TFTP, Auto IP, Telnet, BOOTP
Configuration Options: Web Console, Serial Console (Serial
Command Mode), Telnet Console, Windows Utility
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Ordering Information
Available Modules
MiiNePort E1: Embedded device server module for TTL devices supporting
10/100BaseT(x) with RJ45 connector, 0 to 55°C operating temperature
MiiNePort E1-T: Embedded device server module for TTL devices supporting
10/100BaseT(x) with RJ45 connector, -40 to 75°C operating temperature
• MiiNePort E1 Series module
Package Checklist (starter kits)
Available Starter Kits
•
•
•
•
•
•
•
•
•
MiiNePort E1-ST: Starter kit for the MiiNePort E1 Series
8-44
Package Checklist (modules)
w w w. m o x a . c o m
[email protected]
MiiNePort E1 module
MiiNePort E1-ST evaluation board
Universal power adaptor
2 power cords
Null modem cable
Cross-over Ethernet cable
Document and Software CD
Quick Installation Guide
Warranty Card
Industrial Networking Solutions
NE-4100 Series
10/100 Mbps embedded serial device servers
NE-4110S/4110A
NE-4120S/4120A
NE-4100T
› 10/100 Mbps Ethernet interface
› Up to 230.4 Kbps baudrate support
› Choice of operation modes: Real COM, TCP Server, TCP Client,
and UDP
› DHCP, BootP, Static IP, and ARP supported
› SNMP and e-mail alerts for event trapping and notification
› Half the size of a credit card—only 57 × 40 mm
› Low power consumption at 1.5W, with single +5V input
8
The certification logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifications” below.
Moxa’s NE-4100 embedded device servers are designed for
manufacturers who want to add sophisticated network connectivity
to their serial devices. Moxa’s embedded device servers can be used
to convert any device with a standard serial interface to an Ethernetenabled device in no time. The NE-4100 embedded device servers
support 10/100 Mbps Ethernet, and provide ready-to-use operation
modes, including TCP Server, TCP Client, and UDP. In addition, a
Real COM driver is included for backward compatibility with legacy
software.
SNMP and E-mail Alerts for Event Trap and Notification
NE-4100 embedded device servers can be configured to send an
SNMP trap or e-mail under the following conditions:
• Change in DSR/DCD line signal
• Change in IP address
• Change in password
• Cold/warm start
• Password authentication failure
Serial Device Servers > NE-4100 Series
Overview
On-site Configuration with Serial Command Mode
• Easy on-site configuration of network settings
• Simple command frame format
• Comprehensive command set for serial and network configuration
• Easily switch between software and hardware triggers
• Software reset
Typical Installation Examples
NE-4110: RJ45 Ethernet connector in
stand-alone form factor
NE-4120: Pin-header Ethernet in
stand-alone form factor
[email protected]
NE-4100T: Dual-in-line pin header in
drop-in form factor
w w w. m o x a . c o m
8-45
Serial-to-Ethernet Solutions
Powerful, User-friendly Utilities
Web-based Configuration
Configure and manage embedded device servers with
Moxa’s Windows Utility
NE-4100 embedded device servers can be configured with the
web console, which can be accessed from the web browser of any
networked computer.
Network Enabler Administrator is a powerful, Windows-based
configuration and management tool for NE-4100 embedded device
servers. With Network Enabler Administrator, users can modify IP
addresses, update communication parameters, and configure all other
settings over the network. This utility has the following useful features:
•
•
•
•
Search your LAN for embedded device servers
Export and import configuration parameters
Upgrade firmware over the network
Remotely monitor data traffic, serial line status,
and TCP/IP connections
• Configure SNMP and e-mail alerts
8
Serial Device Servers > NE-4100 Series
Search for installed
embedded device servers
System log for cold boot,
warm boot, etc.
Remotely configure serial, network, alarm, and other parameters
NE-4100 Starter Kit
The Network Enabler Starter Kit includes an evaluation board, power
adaptor, software, and serial and Ethernet cables to allow quick
and easy evaluation of all embedded device server functions. The
evaluation board is equipped with serial, Ethernet, digital I/O, and
power circuits to help you test your modules and applications.
Null Modem Cable
Power Cord
(US or Euro plug)
Cross-over
Ethernet Cable
Power Adaptor
(90 to 240 VAC,
12 VDC)
Document &
Software CD
Application Board
Dimensions and Pin Assignment
NE-4110S/4110A
NE-4120S/4120A
57 mm (2.24 in)
RJ45
CN
16-bit
Micro
Processor
PIN
1
2
3
6
w w w. m o x a . c o m
45 mm (1.77 in)
8
Signals
Tx+
TxRx+
Rx-
34 mm (1.34 in)
J1
1
40 mm (1.57 in)
34 mm (1.34 in)
40 mm (1.57 in)
8-46
J2
J3
57 mm (2.24 in)
45 mm (1.77 in)
[email protected]
J2
J1
Ethernet
Pin-header
J3
16-bit
Micro
Processor
1
2
3
4
5
Tx+
TxRx+
Rx-
Industrial Networking Solutions
NE-4110/4120 Series
NE-4110S/4120S
NE-4110A/4120A
J1
J1
J2
GND 14 13 VCC(+5V)
GND 12 11 VCC(+5V)
DIO0 10 9
10M_LED
DIO1 8
7
100M_LED
DIO2 6
5
Ready_LED
DIO3 4
3
Reset
TxD1 2
1
RxD1
NC
CTS0
DSR0
DTR0
10
8
6
4
RxD0 2
9
7
5
3
1
NC
RTS0
GND
TxD0
DCD0
NC
NC
NC
RxD- (Data-)
TxD+
10
8
6
4
2
9
7
5
3
1
NC
NC
GND
RxD+ (Data+)
For 2-wire RS-485
mode, Pin 3 is Data+,
Pin 4 is Data-
TxD-
NE-4110T
Pin No.
14
15
16
17
18
19
20
21
22
23
24
25
26
36 mm (1.42 in)
Signal
ETx+
ETxERx+
ERxLED 10M
TxD0
RxD0
RTS0
CTS0
Reset
GND
GND
TxD1
Signal
PIO0
PIO1
PIO2
PIO3
LED 100M
DCD0
DSR0
DTR0
GND
Ready LED
+5V
(45 × 36 mm, 26-pin DIL package,
+5V
2.54 mm pitch)
RxD1
45 mm (1.77 in)
Specifications
Form Factor
Type:
NE-4110/4120: Ready-to-go stand-alone modules
NE-4100T: 26-pin dual-in-line package
Dimensions:
NE-4110/4120: 57 × 40 mm (2.24 x 1.57 in)
NE-4100T: 45 × 36 mm (1.77 x 1.42 in)
Weight:
NE-4110S/4110A: 40 g
NE-4120S/4120A/4100T: 20 g
Ethernet Interface
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector:
NE-4110 Series: RJ45
NE-4120 Series: 5-pin pin header
NE-4100T: 26-pin dual-in-line
Magnetic Isolation Protection: 1.5 KV built-in
Serial Interface
Number of Ports: 2
Serial Standards:
Port 1:
NE-4110S/4120S: RS-232
NE-4110A/4120A: RS-422, RS-485-4w, RS-485-2w
NE-4100T: TTL
Port 2:
TTL console port
RS-485 Flow Control: ADDC® (automatic data direction control)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 110 bps to 230.4 Kbps
Serial Signals
TTL:
Port 1: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Port 2: TxD, RxD, GND
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
8
Serial Device Servers > NE-4100 Series
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Digital I/O Pins
GPIO: 4 programmable I/O pins
Software
Network Protocols: ICMP, ARP, IP, TCP, UDP, DHCP, Telnet, HTTP,
SNMP V1/V2c, SMTP
Configuration Options: Web Console, Serial Console, Telnet
Console, Windows Utility
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Operation Modes: Real COM, TCP Server, TCP Client, UDP
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 70°C (-4 to 158°F)
[email protected]
w w w. m o x a . c o m
8-47
Serial-to-Ethernet Solutions
Power Requirements
Input Voltage: 5 VDC (±5%)
Power Consumption: 290 mA @ 5 VDC max.
Regulatory Approvals
EMC: CE EN55022 Class A, FCC Part 15 Subpart B Class A
MTBF (meantime between failures):
NE-4100T: 288173 hrs
NE-4110A: 289573 hrs
NE-4110S: 290276 hrs
NE-4120A: 289573 hrs
NE-4120S: 285874 hrs
Reliability
Warranty
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Ordering Information
Available Modules
8
Serial Device Servers > NE-4100 Series
8-48
Package Checklist (modules)
NE-4110S: Device server module for RS-232 devices, supports 10/100BaseT(x) with
RJ45 connector
NE-4110A: Device server module for RS-422/485 devices, supports 10/100BaseT(x) with
RJ45 connector
NE-4120S: Device server module for RS-232 devices, supports 10/100BaseT(x) with
5-pin Ethernet pin header
NE-4120A: Device server module for RS-422/485 devices, supports 10/100BaseT(x) with
5-pin Ethernet pin header
NE-4100T: Device server module for TTL devices, supports 10/100BaseT(x) with DIL
package
Available Starter Kits
NE-4110-ST: Starter kit for the NE-4110S and NE-4110A
NE-4120-ST: Starter kit for the NE-4120S and NE-4120A
NE-4100-ST: Starter kit for the NE-4100T
w w w. m o x a . c o m
[email protected]
• NE-4100 series module
Package Checklist (starter kits)
• NE-4100-ST or NE-4110-ST or
NE-4120-ST evaluation board
• Universal power adaptor
• 2 power cords
• Null modem cable
• Cross-over Ethernet cable
• Document and Software CD
• Quick Installation Guide (printed)
• Warranty Card
Industrial Networking Solutions
WE-2100T Series
Wireless LAN embedded serial device servers
› Connects serial devices to IEEE 802.11a/b/g networks
› Choice of operation modes: Real COM, TCP Server, TCP Client,
UDP, and RFC2217
› Windows (including Vista!) real COM and Linux fixed TTY
drivers provided
› Wireless security with WEP, WPA, and WPA2
› Select any baudrate between 50 bps and 921.6 Kbps
› 9 programmable digital I/O channels
› SSL/SSH encryption for configuration
› Compact size and easily mounted housing
Overview
The WE-2100T is a secure and compact embedded wireless module
for connecting serial devices to access points in infrastructure mode,
or to other WE-2100T’s in ad-hoc mode. When using the WE-2100T,
complex RF know-how is not needed to connect serial devices to
a wireless Ethernet network. Encryption for secure data transfer is
supported, along with the 802.11a/b/g radio specifications.
Operation Modes for Embedded Applications
The WE-2100T supports Real COM, TCP Server, TCP Client, UDP,
and RFC 2217 operation modes, which are designed to fulfill the
requirements of embedded module applications. Complete driver
support for Real COM mode is included and easy to install.
On-site Configuration with Serial Command Mode
• Easy on-site configuration of network settings
• Simple command frame format
• Comprehensive command set for serial and network configuration
• Easily switch between software and hardware triggers
• Software reset
Serial Device Servers > WE-2100T Series
The certification logos shown here apply to some or all of the
products in this section. For details, see “Regulatory Approvals”
under “Specifications” below.
8
Specifications
Form Factor
Type: Small metal housing that encloses advanced ARM-based 32-bit
processor; supports both wireless and Ethernet connections
Dimensions: 54 x 40 x 13.3 mm (2.13 x 1.57 x 0.52 in)
Weight: 100 g
Automatic Network Selection
Wireless or Ethernet: The WE-2100T will activate the Ethernet
connection if detected at boot-up. If an Ethernet connection is not
detected, the WE-2100T will choose wireless as the communication
interface. Which interface to use can also be configured with the
WE-2100T’s configuration utilities.
Ethernet Interface
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 44-pin dual-in-line
Magnetic Isolation Protection: 1.5 KV built-in
WLAN Interface
Standard Compliance: IEEE 802.11a/b/g
Network Mode: Infrastructure mode (a/b/g), Ad-Hoc mode (b/g)
Spread Spectrum Technology: DSSS, CCK, OFDM
Transmit Power:
5.15 to 5.25 GHz: 15 dBm @ 6 Mbps; 12 dBm @ 54 Mbps 5.725 to
5.825 GHz: 15 dBm @ 6 Mbps; 12 dBm @ 54 Mbps
2.412 to 2.483 GHz: 17 dBm @ 6 Mbps; 15 dBm @ 54 Mbps
2.412 to 2.472 GHz: 18 dBm @ 1 to 11 Mbps
Receive Sensitivity:
5.15 to 5.25 GHz: 6 Mbps @ -90 dBm; 54 Mbps @ -72 dBm
5.725 to 5.825 GHz: 6 Mbps @ -89 dBm; 54 Mbps @ -72 dBm
2.412 to 2.483 GHz: 6 Mbps @ -90 dBm; 54 Mbps @ -73 dBm
2.412 to 2.472 GHz: 11 Mbps @ -87 dBm; 1 Mbps @ -94 dBm
Transmission Rate:
802.11a: 54 Mbps
802.11b: 11 Mbps
802.11g: 54 Mbps
Transmission Distance: Up to 100 meters (in open areas)
Wireless Security: AES, WEP 64/128-bit, WPA, WPA2, PSK, 802.11i
802.11i Authentication: TLS, PEAP/GTC, PEAP/MD5, PEAP/
MSCHAPv2, TTLS/PAP, TTLS/CHAP, TTLS/MSCHAP, TTLS/
MSCHAPv2, TTLS/EAP-MSCHAPv2, TTLS/EAP-GTC, TTLS/EAP-MD5,
LEAP
Channels:
North America: CH1 to CH11, 5150-5825 MHz
Europe: CH1 to CH13, 5150-5875 MHz
Japan: CH1 to CH14, 5150-5350 MHz
[email protected]
w w w. m o x a . c o m
8-49
Serial-to-Ethernet Solutions
Environmental Limits
Antenna Connector: Reverse SMA
Antenna Gain: 2 DBi
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 70°C (-4 to 158°F)
Serial Interface
Number of Ports: 1
Serial Standards:
Port 1: TTL
Port 2: TTL console port
Surface Temperature (at full baudrate of 921.6 Kbps)
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps (non-standard buadrates supported)
8
Serial Signals
TTL:
Port 1: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Port 2: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Software
Serial Device Servers > WE-2100T Series
Network Protocols: ICMP, IP, TCP, UDP, DHCP, Telnet, DNS, SNMP
V1/V2c, HTTP, SMTP, SNTP, SSH, HTTPS
Configuration Options: Web Console, Serial Console, Telnet Console,
Windows Utility, Serial command mode (configured through the data
port)
Windows Real COM Drivers: Windows 95, 98, ME, NT, 2000, XP
x86/x64, 2003 x86/x64, Vista x86/x64, 2008 x86/x64, Embedded CE
5.0/6.0, XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7,
UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX
5.x, HP-UX 11i
Linux Real TTY Drivers: Linux kernel 2.4.x, 2.6.x
Operation Modes: Real COM, TCP Server, TCP Client, UDP, RFC2217
Top Panel:
43.0°C, when air temp = 25°C
55.0°C, when air temp = 55°C
Bottom Panel:
44.5°C, when air temp = 25°C
67.0°C, when air temp = 55°C
Power Requirements
Input Voltage: 3.3 VDC (±5%)
Power Consumption:
921.6 Kbps (full speed): 540 mA
Idle: 190 mA
Ethernet mode: 670 mA
Inrush current: 2100 mA
Regulatory Approvals
EMC: CE (EN55022 and EN55024 Class A, ETSI EN 301 489-17, ETSI
EN 301 489-1)
Safety: UL (UL60950-1), TÜV (EN60950-1)
EMI: FCC Part 15 (Subpart B Class A, Subpart C, Subpart E)
Radio: CE (ETSI EN 301 893, ETSI EN 300 328), ARIB RCR STD-33,
ARIB STD-66
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
WE-2100T: 505288 hrs
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions and Pin Assignment
0.3 mm (0.01 in)
1.27 mm (0.05 in)
16.8 mm
(0.66 in)
13.3 mm
(0.52 in)
40 mm
(1.57 in)
9.63 mm
(0.38 in)
8.36 mm
(0.33 in)
18.25 mm
(0.72 in)
WE-2100T
V1.0
Moxa Technologies Co., Ltd.
BqfNL010000
00:90:E8:OA:B1:CB
Made in Taiwan
3.3V
3.3V
3.3V
Console_TxD
Console_RTS
Console_DTR
PIO0
PIO1
PIO2
PIO3
Data_TxD
Data_RTS
Data_DTR
Ready_LED
Fault_LED
Eth_Tx+
Eth_TxEth_Center_TAP
Eth_Center_TAP
Eth_Rx+
Eth_RxPIO8(WLAN strength 0)
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
GND
GND
GND
Console_RxD
Console_CTS
Console_DSR
Console_DCD
PIO4(WLAN strength 1)
PIO5(WLAN strength 2)
PIO6(WLAN strength 3)
PIO7(WLAN strength 4)
Data_RxD
Data_CTS
Data_DSR
Data_DCD
WLAN_Active_LED
SW_RESET
HW_RESET
Eth_100M_LED
Eth_10M_LED
Reserved
Reserved
Ordering Information
Available Modules
Package Checklist (module)
Package Checklist (starter kit)
WE-2100T: 1-port wireless module supporting
IEEE 802.11a/b/g
•
•
•
•
•
•
•
•
WE-2100T wireless module
IEEE 802.11a/b/g Antenna
Available Starter Kits
WE-2100T-ST: Starter Kit for the WE-2100T
8-50
w w w. m o x a . c o m
[email protected]
WE-2100T-ST evaluation board
WE-2100T wireless module
Power adaptor
Document and Software CD
Quick Installation Guide (printed)
Warranty Card