Download Siemens BH17 7ER Installation guide

Transcript
Mobility and Logistics, Traffic Solutions
Sopers Lane, Poole, Dorset, BH17 7ER
The other boards in the system are powered over the RJ45 GSPI cables.
It is important that only supplied RJ45 cables are used as the cable must
carry all of the supply current. (Certain cheaper RJ45 cables are known to
have very thin conductors which will cause a problem if used on a Stratos
Outstation).
5.6
Controller Serial Connection
The Stratos Outstation can be connected to the TR 2523 port of a traffic controller using
the correct RS232 interface cable and baud rate as shown in the tables below:
Supplier
Controller
RS232 Baud Rate
RS232 Cables (see Table 25)
Siemens
ST950
19200
Standard
ST800
19200
Standard
ST900
19200
Standard
ST750
19200
Standard
ST700
19200
Standard
T400
1200
Standard
T500
1200
Standard
MPC
1200
Standard + Extension
MTC
1200
Standard + Extension
Sentinel
1200
Standard
Optima
1200
Loopback
TSC3
1200 (19200*)
Loopback
TRX
9600 (19200*)
Loopback
PTC-1
9600 (19200*)
Loopback
TSP
1200 (19200*)
Loopback
TM150
115200
Loopback
Microsense /
Telent
Peek
Motus
TM150 2P
115200
Loopback
* This baud rate can be set by the BDR handset command.
Table 24 – Controller RS232 Baud Rates and Cable Variants
RS232
Cable
Description
Part Number
Standard
This is a 1.6 metre cable for controllers which drive 667/1/47176/100
hardware flow control signals DTR & RTS. The cable
terminates in 25-way D-type plug.
This cable is supplied as standard with the outstation.
Security classification Unrestricted
Page
55 of 84
Version
1
Status
Issued
Last Editor
Carl Rabe
Date
11-Dec-2014
Document Name
Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc