Download Mitsubishi 20-MYA Specifications

Transcript
AIR-COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS
DATA BOOK
Series :
PE(H)
Cooling only
Heat pump
Model
PE-7MYC
PE-8MYC
PE-10MYC
PE-15MYC
PE-20MYC
Service ref.
PE-7MYC-EU
PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU
PE-20MYC-EU
PEH-5MYA
PEH-7MYA
PEH-8MYA
PEH-10MYA
PEH-15MYA
PEH-20MYA
PEH-5MYA-EU
PEH-7MYA-EU
PEH-8MYA-EU
PEH-10MYA-EU
PEH-15MYA-EU
PEH-20MYA-EU
CONTENTS
SAFETY FOR USE ------------------------------------------------------2
A COMPLETE LINE UP ------------------------------------------------4
FEATURES-----------------------------------------------------------------5
DESCRIPTIONS----------------------------------------------------------5
MECHANICAL SPECIFICATIONS ----------------------------------6
TYPICAL INSTALLATION EXAMPLE ------------------------------6
MODEL-DESIGNATION BREAKDOWN ---------------------------7
SPECIFICATIONS -------------------------------------------------------8
ELECTRICAL DATA ----------------------------------------------------11
SELECTION PROCEDURE -----------------------------------------16
CAPACITY TABLES ----------------------------------------------------18
CAPACITY REDUCTION RATIO DUE
TO CHANGES IN PIPING LENGTH ------------------------------36
OPERATION RANGE--------------------------------------------------37
FAN PERFORMANCE-------------------------------------------------38
SOUND DATA------------------------------------------------------------41
APPROXIMATION FOR SOUND POWER
LEVEL AT SUPPLY DUCT FLANGE OF UNIT------------------42
OUTLINE DIMENSIONS----------------------------------------------43
WIRING DIAGRAMS---------------------------------------------------50
ELECTRICAL OPERATION FLOW CHARTS -------------------63
REFRIGERANT SCHEMATICS-------------------------------------66
SAFETY & CONTROL DEVICES ----------------------------------67
SPECIAL ORDER ------------------------------------------------------69
PHYSICAL DATA--------------------------------------------------------70
INSTALLATION ----------------------------------------------------------79
INSTRUCTIONS FOR USE ------------------------------------------96
HOW TO OPERATE -------------------------------------------------101
LOW AMBIENT COOLING PARTS;
OPTION;PAC-205FC (Fan controller)----------------------------104
SPECIFICATION GUIDELINES -113
Specifications subject to change without notice.
-1-
SAFETY FOR USE
Before conducting installation work, please read this ''SAFETY FOR USE'' carefully
for correct installation.
Since the caution items shown here contain important description relative to safety, please
observe them without fail.
Warning
Erroneous handling gives a high possibility to induce serious results such as
death or heavy injury.
Caution
Erroneous handling may induce serious injury depending on the situation.
After reading, please keep it with you together the Instruction Manual, and read it again at the
movement of the unit.
Warning
Never repair the unit, remodel or transfer it to
another site by yourself.
If they are performed improperly, water leakage, electric
shock or fire may result. If you need to have the unit
repaired or moved, consult your dealer.
Ask your dealer or specialized subcontractor
for installation.
Conducting installation work by yourself improperly
may cause a fire, electric shock or water leakage.
For installation, conduct the work correctly by
following the Installation Manual.
Improper installation may cause a fire, electrical shock
or water leakage.
Use only the specified refrigerant (R-22) to charge
the refrigerant circuit.
Do not mix it with any other refrigerant and do not
allow air to remain in the circuit.
Air enclosed in the circuit can cause high pressure resulting
in a rupture and other hazards.
Install the unit on a spot sufficiently durable against
the unit weight.
Insufficient durability can cause an injury by the falling
down of unit.
Ventilate the room if refrigerant leaks during
Installation.
The refrigerant heated generates poisonous gas by
decomposition which can cause poisoning.
All electric work must be performed by licensed
technician, according to local regulations and the
instructions given in this manual.
The units should be powered by dedicated power
lines.
Power lines with insufficient capacity or improper
electrical work may result in electric shock or fire.
After completing installation work, make sure that
refrigerant gas has not leaked.
If refrigerant gas has leaked and exposed to fan heater,
stove, oven and so on, it may generate noxious gases.
Please do the gas leakage inspection before starting.
Use only the specified cables for wiring. The
connections must be made secured without
tension the terminals.
Improper connection or fastening can cause a fire or
electrical shock.
The unit should be installed according to the
instructions in order to minimize the risk of damage
from earthquakes, typhoons or strong winds.
Improper installation work can cause an injury by the
falling down of the unit.
Take a proper measure to suppress the critical
concentration of refrigerant if leaked when
installing the unit in a small room.
The limit density is made not to be exceeded even if the
refrigerant leaks by any chance.
You are necessary to ventilation measures to prevent
the accident. If the refrigerant leaks, hypoxia accident
may caused.
For the countermeasure to be taken, consult your
dealer.
The outdoor unit must be installed on stable, level
surface, in a place where there is no accumulation
of snow , leaves or rubbish.
The outdoor unit should be installed in a location
where air and noise emitted by the unit will not
disturb the neighbors. The indoor unit should be
securely installed.
If the unit is loosely mounted, it may fall, and cause injury.
The terminal block cover of unit must be firmly
attached to prevent entry of dust and moisture.
Improper mounting of the cover cause electric shock or
fire.
The heating of refrigerant is noted.
When the refrigerant touches the fire etc., it was decomposed and a poisonous gas is generated.
Do not use the welding machine etc., in the room close up
of the installation of the air conditioner.
Use only optional parts authorised by Mitsubishi
Electric.
If the accessories are installed improperly, water
leakage, electric shock or fire may result.
Ask your dealer or an authorised company to install
them.
-2-
Caution
Arrange the configuration of wiring not to bring up
the panel and terminal cover, and fasten the panel
and terminal cover securely.
The poor mounting of the panel or terminal cover may
cause the heat generation of the terminal connection,
a fire or electrical shock.
Never install on the place where a combustible
gas might leak.
The gas may ignite or explode when the gas leaks and
collects in surround of the unit.
When the unit is installed at telecommunication
centers or hospitals, take a proper provision
against noise.
The erroneous operation of air conditioner may be
induced by inverter equipment, independent power
device, medical equipment or communication
equipment.
Do not wash the unit with water.
If washed with water, electric shock may be caused.
Do not handle the switch with wet hands.
Otherwise electric shock can be resulted.
Be very careful about unit transportation.
The unit should not be carried by only one person if it is
more than 20kg. It occasionally causes the damage of
the unit and health to be impaired.
Some unit use PP bands for packing. Do not use any PP
band for delivery purpose. It may cause the injury.
Do not touch the heat exchanger fins with your bear hands.
Doing so may cut your hands.
When carrying in outdoor unit, be sure to support it at four
points. Carrying in and lifting with 3-point support may
make outdoor unit unstable, resulting in a fall of it.
Be sure to safety dispose the packing materials.
Packing materials, such as catches and other metal or
wooden parts, may cause stabs or other injuries.
For special use as for foods, animals/plants,
precision equipment or art objects, the applicability
should be confirmed beforehand.
As the use for the applications other than that
designed originally may result in the deterioration of the
quality. Consult your dealer in this regard.
Do not use the unit under a special atmosphere.
Installing the unit at the following places may cause a
trouble, a place where is much machine oil, salt ,
humidity or dust, spa district, a place full of sulfur gas,
volatile gas, or corrosive gas, a place near high
frequency processing machine.
Thermal insulation of the drain pipes is necessary
prevent dew condensation.
If the drain pipes are not properly insulated,
condensation will result and drip on ceiling, floor or other
possessions.
Do not leave the mounting base being damaged.
The damaged base may cause the falling down of the
unit which may give injury.
The unit should be securely installed level surface.
When the unit inclines, it causes the water leak and the
breakdown.
Please confirm the horizontal with the spirit level.
Turn on the main power switch more than 6 hours
before starting operation.
Do not turn the main power switch OFF during seasons
of heavy use, doing so can result in failure.
Install drain piping (hose) according to this
Installation Manual to ensure proper drainage.
Improper drain piping (hose) may cause water leakage
and damage to furniture or other possessions.
Do not touch the compressor or refrigerant piping
without wearing glove on your hands.
Touching directly such part can cause a burn or
frostbite as it becomes high or low temperature
according to the refrigerant state.
The unit must be properly earth connected.
Do not connect the earth wire to gas pipe, city water
pipe, lightning rod or telephone earth wire.
Improper earth connection may cause electrical shock.
Do not touch the metal edges inside the unit
without wearing glove on your hands.
Touching directly it may injure your hands.
When installing at a watery place, provide an
electric leak breaker.
Failure to mount the electric leak breaker may cause
electrical shock.
Do not remove the panel or the fan guard from the
unit when it is running.
You could be injured if you touch rotating, hot or highvoltage parts.
Use breaker or fuse with proper capacity.
Make sure that each appliance has a main power
switch.
Using a wire or copper wire instead of proper capacity
can cause fire or trouble.
Other appliances connected to the same line could cause
an overload.
Do not operate the air conditioner without the air
filter set place.
Dust may accumulate, and cause a failure.
For the power lines, use standard cables of
sufficient current capacity.
Otherwise, current leakage, overheating or fire may
occur.
At emergency (if you smell something burning), stop
operation and turn the power source switch off.
Continuing the operation without eliminating the
emergency state may cause a machine trouble, fire, or
electrical shock.
After stopping operation, be sure to wait for five
minutes before turning off the main power switch.
Otherwise, water leakage or unit failure may occur.
When installing the power lines, do not apply
tension to the cables.
The tighten or loosen the connections may cause
generate heat and cause fire.
Remote controller is not installed for the place
where direct sunshine strikes.
Remote controller should be pushed with finger
Remote controller may be broken.
Do not place objects under the units to avoid
damage of condensation.
When the room is high humidity or when the drain pipe
is clogged, water may drip from the indoor unit.
-3-
A COMPLETE LINE UP
Cooling capacity
Heating capacity
(PEH only)
PEH-5
PE(H)-7
PE(H)-8
PE(H)-10
PE-15/PEH-15
PE(H)-20
kW
14.4
17.9
22.0
28.8
47.0/44.0
57.6
Btu/h
49,150
61,100
75,100
98,300
160,400/150,200
196,600
kcal/h
12,400
15,400
18,900
24,800
40,500/37,900
49,500
kW
14.4
18.8
22.0
28.8
44.0
57.6
Btu/h
49,150
64,100
75,100
98,300
150,200
196,600
kcal/h
12,400
16,200
18,900
24,800
37,900
49,500
Note: Cooling & heating capacities are based following conditions.
Cooling: Indoor:27 DB, 19
WB; Outdoor: 35 DB
Heating: Indoor:21 DB; Outdoor: 7
DB, 6 WB (PEH only)
Cooling and Heating capacities are based 5m pipe length
Indoor unit
Example PEH-8
Outdoor unit
Example PUH-8
-4-
FEATURES
Highly efficient operation
Labour saving installation
The EER(Energy Efficiency Ratio) on these models
is greatly improved by revised design specifications
and by being manufactured stringently to Mitsubishi
Electric high quality standards.
The unit operation can commence immediately after
connecting to the power supply, refrigerant piping,
drain piping, ducting and control system.
Wide electrical control capability
Comfort heating (PEH only)
All models are flexible mechanical control configulation.
In addition Global Remote Controller is prepared
on standard.
The Global Remote Controller give the below function.
• Cool/Heat/Fan/Auto Changeover
3 pattern select (Change to switch inside R/C)
· Cool/Fan
· Cool/Heat/Fan
· Cool/Heat/Fan/Auto Changeover
(Heat and Auto Change over one only PEH)
• 2 step control (PE(H)-15, 20 only)
• Compressor Anti-short cycle timer (3 min)
• Programmable weekly timer
ON/OFF time setteing on 7-days
• Real time clock
• Built in Return air temperature Sensor
(Option : Outside sensor)
• Power failure comeback
• Error indicator
· Room temperature sensor Error
• Key Lock
Key lock except ON/OFF key
The PEH models are designed to provide effective
heating even when the outside temperature is down
to -10˚C.
High sensible cooling capacity
The sensible cooling capacity has been significantly
improved through balanced optimised heat
exchanger design.
Flexibility of Supply Air Delivery
PE, PEH-15,20 feature belt driven Supply Air fans
enabling accurate matching of actual airflow rates
to the specified quantities. Accurate commissioning
is assisted by the capability to change pulleys and
belts if necessary to achieve the desired air balance.
Low ambient cooling (Special order)
In applications with relatively high internal loads,
there may be a requirement for all series to
operate on cooling at low ambient conditions.
Special order parts is available to maintain the
refrigeration circuit in balance at outdoor temperatures
as low as -5˚C.
Please consult your local Mitsubishi Electric Sales
office for application advice on these parts.
Grobal Remote Controller
DESCRIPTIONS
With the development of all series demands
for such features as light weight, compactness,
increased capacity, appropriate static pressure, air
flow control, and having flexibility of inter facing
energy saving electronic controls, Mitsubishi
Electric have met market expectations.
Mitsubishi Electric air conditioners series PE(H)/PU(H)
are available in a wide range of sizes and models to
enables the designer to select the best model for
each application.
All series units are completely assembled, wired and
strictly tested at the factory.
- 5-
MECHANICAL SPECIFICATIONS
General
Condenser Coils
All units are factory assembled, piped, internally wired.
They are also tested and checked under a strict quality
control system in the factory.
Exterior surfaces of all units of outdoor unit are
phosphatized, zinc-coated steel with powder coating
and ivory white baked enamel finish.
Unnecessary power input due to higher discharge
pressure is avoided by high performance designs of
cross-finned coil.
Condenser coils are made of 9.52mm OD, 0.35mm
thick seamless copper tubes mechanically bonded to
0.12mm thick aluminium fins and factory pressure
and leak tested at 3.3MPa.
Refrigeration Controls
Refrigeration controls include condenser fan,
evaporator fan and compressor contactors.
Compressors
All units have high efficiency type hermetic line starting
compressors.
Compressors are equipped with thermal overload
protector, over-current relay and high pressure
protection control.
Crankcase heaters are standard.
Evaporator Fans
The sirocco fans are made of galvanized steel or plastic
and balanced to proved accurate air flow performance
at low noise level.
Condenser Fan
The direct-drive propeller fan is dynamically balanced,
to ensure smooth airflow.
A weatherproof three-phase squirrel cage induction
motor is used to drive the condenser fan.
Evaporator Coils
Highly efficient cross-finned coil are applied to provide a
larger cooling capacity with low air speed on the coil.
Coils are made of 9.52mm OD and 0.35mm thick
seamless copper tubing mechanically bonded to 0.12mm
thick aluminium fins and are factory leak tested at a
pressure of 3.3MPa. They are provided with strainers
attached to the capillary tubes to further ensure a clean
system.
TYPICAL INSTALLATION EXAMPLE
PU(H)
PE(H)
PE(H)
PU(H)
- 6-
MODEL-DESIGNATION BREAKDOWN
P E - 10 M Y C 1
Service reference
Design Sequence
Electrical Supply
Y = 3 phase 380~415V 50Hz 4 wires
of PE(H)-7 Indoor unit
( InY =case
1 phase 220~240V 50Hz 2 wires )
Compressor Horsepower
5 = 5 HP
7 = 7 HP
8 = 7.5 HP
10= 10 HP
15= 15 HP
20= 20 HP
Series Number
PE = Indoor unit
PEH = Indoor unit
PU = Outdoor unit
PUH = Outdoor unit
-7-
SPECIFICATIONS
Cooling only
PE-7~20MYC
PE-7MYC
PE-8MYC
PE-10MYC
PE-15MYC
PE-20MYC
PE-7MYC-EU
PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU
PE-20MYC-EU
kW
Btu/h
kcal/h
17.9
61,100
Sensible cooling capacity
(Gross)
kW
Btu/h
kcal/h
14.3
48,800
22.0
75,100
18,900
17.6
60,100
15,100
28.8
98,300
24,800
23.0
78,500
19,800
47.0
160,400
40,400
37.6
128,300
32,300
57.6
196,600
49,500
46.1
157,300
39,600
Total cooling capacity
(Net)
kW
Btu/h
kcal/h
17.2/17.1
58,700/58,300
21.4
73,000
18,400
27.8
94,900
23,900
45.5/45.3
155,200/154,600
39,100/39,000
56.1/55.2
191,400/188,300
48,200/47,500
Model name
Service
reference
Total cooling capacity
(Gross)
Power supply
kg
Service
reference
Width
Depth
Height
Net weight
Indoor coil
Indoor fan
Indoor fan motor
Motor output
Indoor fan air flow
External static
pressure
Sound pressure level
Drain connection
Outdoor unit
Model name
mm
mm
mm
kg
Width
Depth
Height
Net weight
Compressor
No. ✕ Motor output
Crankcase heater
Outdoor coil
Outdoor fan
Outdoor fan motor
No. ✕ Motor output
Outdoor fan air flow
Sound pressure level
Protection devices
3N~ 380~415V 50Hz
3N~ 380~415V 50Hz
0-100
0-50-100
5.7
5.0
R-22
8.7
Capillary tube
PE-7MYC
PE-8MYC
PE-10MYC
PE-15MYC
PE-20MYC
PE-7MYC-EU
PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU
PE-20MYC-EU
Galvanized steel
1,615
1,690
1,415
67
650
428
70
2 ✕ 4.8
2 ✕ 9.7
1,993
865
706
84
180
212
Cross fin coil
Centrifugal (plastic) - Direct drive
Centrifugal (plastic) - Belt drive
Three phase induction motor
Single phase induction motor
3.7
0.7
1.0
kW
2.2
0.21
CMM
60
70
90
140
180
CFM
2,119
2,472
3,179
4,945
6,358
L/S
1,000
1,167
1,500
2,333
3,000
5/12.5
mmAq
10/20
6.2/12.5
50/125
Pa
62/125
100/200
55
56
59
61
62
dB(A)
mm
25.4
Service
reference
External finish
Dimension
14,800/14,700
%
Refrigerant control
Indoor Unit
Model name
External finish
Dimension
12,300
~ 220~240V 50Hz
3N~ 380~415V 50Hz
Indoor
Outdoor
Capacity step
Refrigerant
Refrigerant charge
15,400
PU-7MYC
PU-8MYC
PU-7MYC1-EU(S)
PU-8MYC1-EU(S)
kW
W
kW
CMM
CFM
L/S
dB(A)
PU-15MYC
202
1 ✕ 5.0
62
205
230
285
Hermetic line start(reciprocating)
1 ✕ 5.5
1 ✕ 7.5
2 ✕ 5.5
62
72
2 ✕ 62
Cross fin coil
Propeller-Direct drive
Three phase induction motor
2 ✕ 0.09
2 ✕ 0.15
190
210
220
6,711
7,415
7,770
3,167
3,000
3,667
65
65
65
High pressure switch, freeze & frost protection, Fuse
Over current relay (comp & indoor fan, outdoor fan)
Internal thermostat (comp & indoor fan, outdoor fan)
1 ✕ 0.24
240
8,477
4,000
67
Note1. Cooling capacity and sound pressure level are based on the following conditions.
Indoor;27˚CDB,19˚CWB, Outdoor;35˚CDB
Cooling capacity is based 5m pipe length.
2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit.
3. Gross capacity do not include a deduction for evaporator fan motor heat.
4. The measuring point of the Sound pressure level is 1m from the unit front surface.
5. Specification subject to change without notice.
-8-
PU-20MYC
PU-10MYC1-EU(S) PU-15MYC1-EU(S)
Acrylic resin coating (Munsell 5Y 8/1)
1,400
998
700
980
1,230
mm
mm
mm
kg
PU-10MYC
PU-20MYC1-EU(S)
1,996
998
961
360
2 ✕ 7.5
2 ✕ 72
2 ✕ 0.24
480
16,954
8,000
68
PEH-5,7,8MYA
Model name
Service
reference
Total cooling capacity
(Gross)
Heat pump
kW
Btu/h
kcal/h
Sensible cooling capacity
(Gross)
kW
Btu/h
kcal/h
Total cooling capacity
(Net)
kW
Btu/h
kcal/h
Heating capacity
(Gross)
kW
Btu/h
kcal/h
Heating capacity
(Net)
kW
Btu/h
kcal/h
Power supply
Indoor
Outdoor
Capacity step
Refrigerant
Refrigerant charge
Refrigerant control
Indoor Unit
Model name
PEH-7MYA
PEH-8MYA
PEH-5MYA-EU
PEH-7MYA-EU
PEH-8MYA-EU
14.4
49,100
12,400
11.5
39,200
9,900
13.9
47,400
12,000
17.9
61,100
15,400
14.3
48,800
12,300
17.2/17.1
58,700/58,300
14,800/14,700
22.0
75,100
18,900
17.6
60,100
15,100
21.4
73,000
18,400
13.9
47,400
12,000
14.4
49,100
12,400
3N~ 380~415V 50Hz
3N~ 380~415V 50Hz
18.0
61,400
15,500
18.7/18.8
63,800/64,100
16,100/16,200
~ 220~240V 50Hz
3N~ 380~415V 50Hz
21.4
73,000
18,400
22.0
75,100
18,900
3N~ 380~415V 50Hz
3N~ 380~415V 50Hz
0-100
R-22
%
kg
5.0
5.7
6.6
Capillary tube
Service
reference
External finish
Dimension
PEH-5MYA
PEH-5MYA
PEH-7MYA
PEH-8MYA
PEH-5MYA-EU
PEH-7MYA-EU
PEH-8MYA-EU
Galvanized steel
Width
Depth
Height
Net weight
Indoor coil
Indoor fan
Indoor fan motor
Motor output
Indoor fan air flow
External static
pressure
Sound pressure level
Drain connection
Outdoor unit
Model name
Service
reference
External finish
Width
Dimension
Depth
Height
Net weight
Compressor
Motor output
Crankcase heater
Outdoor coil
Outdoor fan
Outdoor fan motor
No. ✕ Motor output
Outdoor fan air flow
Sound pressure level
Protection devices
mm
mm
mm
kg
1,095
1,415
650
428
60
67
70
Cross fin coil
Centrifugal (plastic) - Direct drive
Three phase induction motor
Three phase induction motor Single phase induction motor
kW
CMM
CFM
L/S
mmAq
Pa
dB(A)
mm
0.45
42
1,483
700
0.7
70
2,472
1,167
6.2/12.5
62/125
56
5/12.5
50/125
55
25.4
PUH-5MYE
PUH-7MYC
PUH-8MYC
PUH-8MYE
PUH-5MYE1-EU
PUH-7MYC2-EU
PUH-8MYC2-EU
PUH-8MYE1-EU
mm
mm
mm
1,000
550
1,175
kg
150
kW
W
3.73
kW
CMM
CFM
L/S
dB(A)
0.21
60
2,119
1,000
Acrylic resin coating (Munsell 5Y 8/1)
1,400
700
980
214
211
Hermetic line start(reciprocating)
5.5
62
Cross fin coil
Propeller-Direct drive
Three phase induction motor
1 ✕ 0.15
2 ✕ 0.09
95
167
3,355
5,898
1,583
2,783
57
65
High pressure switch, freeze & frost protection, Fuse
Over current relay (comp & indoor fan, outdoor fan)
Internal thermostat (comp & indoor fan, outdoor fan)
Note 1. Cooling, heating capacities and sound pressure level are based on the following conditions.
Cooling
indoor; 27˚CDB, 19˚CWB, outdoor :35˚CDB
Heating
indoor; 21˚CDB,
outdoor :7.0˚CDB, 6.0˚CWB
Cooling and heating capacities are based 5m pipe length.
2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit.
3. Gross capacity do not include a deduction for evaporator fan motor heat.
4. The measuring point of the Sound pressure level is 1m from the unit front surface.
5. Specification subject to change without notice.
-9-
1,250
550
1,175
188
1 ✕ 0.35
200
7,063
3,333
65
PEH-10,15,20MYA
Heat pump
Model name
Service
reference
Total cooling capacity
(Gross)
kW
Btu/h
kcal/h
Sensible cooling capacity
(Gross)
kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
Total cooling capacity
(Net)
Heating capacity
(Gross)
kW
Btu/h
kcal/h
Heating capacity
(Net)
kW
Btu/h
kcal/h
Power supply
PEH-15MYA
PEH-20MYA
PEH-10MYA-EU
PEH-15MYA-EU
PEH-20MYA-EU
27.8
94,900
23,900
27.8
94,900
23,900
27.8
94,900
44.0
150,200
37,900
35.2
120,200
30,200
42.5/41.7
145,000/142,300
36,600/35,900
41.7
142,300
35,900
43.2/44.0
147,400/37,200
150,100/37,800
3N~ 380~415V 50Hz
3N~ 380~415V 50Hz
23,900
27.8
94,900
23,900
28.8
98,300
24,800
Indoor
Outdoor
Capacity step
Refrigerant
Refrigerant charge
Refrigerant control
Indoor Unit
Model name
57.6
196,600
49,500
46.0
157,000
39,600
56.1/55.1
191,400/188,000
48,200/47,400
55.1
188,000
47,400
56.6/57.6
193,100/196,500
48,700/49,500
0-100
%
0-50-100
R-22
kg
9.9
2 ✕ 9.7
2 ✕ 6.6
11.0
Capillary tube
Service
reference
External finish
Dimension
PEH-10MYA
PEH-10MYA
PEH-15MYA
PEH-20MYA
PEH-10MYA-EU
PEH-15MYA-EU
PEH-20MYA-EU
Galvanized steel
Width
Depth
Height
Net weight
Indoor coil
Indoor fan
Indoor fan motor
Motor output
Indoor fan air flow
External static
pressure
Sound pressure level
Drain connection
Outdoor unit
Model name
Service
reference
External finish
Width
Dimension
Depth
Height
Net weight
Compressor
No. ✕ Motor output
Crankcase heater
Outdoor coil
Outdoor fan
Outdoor fan motor
No. ✕ Motor output
Outdoor fan air flow
Sound pressure level
Protection devices
mm
mm
mm
kg
1,615
650
428
84
1,690
1,993
865
706
180
212
Cross fin coil
kW
CMM
CFM
L/S
mmAq
Pa
Centrifugal (plastic) - Direct drive
Centrifugal (plastic) - Belt drive
Three phase induction motor
1.0
2.2
3.7
140
180
90
4,945
6,358
3,179
1,500
2,333
3,000
10/20
6.2/12.5
62/125
59
dB(A)
mm
62
25.4
PUH-10MYC
PUH-10MYE
PUH-15MYC
PUH-20MYC
PUH-10MYC2-EU
PUH-10MYE1-EU
PUH-15MYC2-EU
PUH-20MYC2-EU
mm
mm
mm
1,400
700
980
kg
240
Acrylic resin coating (Munsell 5Y 8/1)
1,250
550
1,175
431
221
1 ✕ 7.5
72
kW
W
kW
CMM
CFM
L/S
dB(A)
100/200
61
472
Hermetic line start(reciprocating)
2 ✕ 5.5
2 ✕ 62
Cross fin coil
Propeller-Direct drive
Three phase induction motor
0.35
200
7,063
3,333
2 ✕ 0.15
190
6,711
3,167
1,951
1,080
1,200
65
2 ✕ 7.5
2 ✕ 72
2 ✕ 0.35
2 ✕ 185
2 ✕ 6,534
2 ✕ 3,083
69
High pressure switch, freeze & frost protection, Fuse
Over current relay (comp & indoor fan, outdoor fan)
Internal thermostat (comp & indoor fan, outdoor fan)
Note 1. Cooling, heating capacities and sound pressure level are based on the following conditions.
Cooling
indoor; 27˚CDB, 19˚CWB, outdoor :35˚CDB
Heating
indoor; 21˚CDB,
outdoor :7.0˚CDB, 6.0˚CWB
Cooling and heating capacities are based 5m pipe length.
2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit.
3. Gross capacity do not include a deduction for evaporator fan motor heat.
4. The measuring point of the Sound pressure level is 1m from the unit front surface.
5. Specification subject to change without notice.
- 10 -
ELECTRICAL DATA
PE-7~20MYC-EU
Cooling
VOLT
PE-7
240V
PE8~20
415V
PE-7
230V
PE8~20
400V
PE-7
220V
PE8~20
380V
ITEM
PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU
PU-7MYC1-EU PU-8MYC1-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU
17.4/17.6
10.1
7.8
21.1/22.0
7.1/7.2
29.1/29.6
19.0
14.2
37.3/39.1
14.2/14.6
83
74
76
78
119
82
83
140
74
2 × 9.2
2 × 7.65
8.6
6.8
6.0
×15.95
2
16.0
12.3
10.7
2 × 12.45
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
Pa
50/125
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.7/0.8
2.8/3.2
0.4
0.7
0.6
1.2
0.4
0.7
1.0
2.0
0.5
1.0
1.5/1.7
3.1/3.5
0.6
1.2
1.5/2.4
3.0/4.8
2 × 0.6
2 × 1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
7.1/7.2
14.7/15.2
77
7.8
14.7
77
86
10.1
19.6
74
85
17.4/17.6
30.2/30.6
83
123
21.1/22.0
38.7/40.5
79/78
145
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
6.0
11.1
6.8
12.8
8.6
16.6
2X7.65
2X12.9
2X9.2
2X16.6
Pa
50/125
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.7/0.8
2.9/3.4
0.4
0.7
0.6
1.2
0.4
0.7
1.0
2.0
0.5
1.0
1.5/1.7
3.2/3.6
0.6
1.2
1.5/2.4
3.1/4.9
2X0.6
2X1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
7.1/7.2
15.5/15.9
81
7.8
15.5
76
91
10.1
20.7
74
90
17.4/17.6
31.8/32.3
83
131
21.1/22.0
40.8/42.7
78
152
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
6.0
11.6
6.8
13.4
8.6
17.6
2 × 7.65
2 × 13.65
2 × 9.2
2 × 17.55
Pa
50/125
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.7/0.8
3.1/3.5
0.4
0.8
0.6
1.3
0.4
0.8
1.0
2.1
0.5
1.0
1.5/1.7
3.4/3.8
0.6
1.2
1.5/2.4
3.3/5.2
2 × 0.6
2 × 1.2
- 11 -
PEH-5,7,8MYA-EU
Cooling
VOLT
ITEM
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
PEH-7
240V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
415V INDOOR FAN INPUT
kW
A
%
A
kW
A
PEH-5MYA-EU PEH-7MYA-EU
PEH-8MYA-EU
PUH-5MYE1-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU
7.8
7.9
5.49
7.1/7.2
14.2
14.7
9.6
14.2/14.6
76
75
80
83
83
69
74
6.8
6.8
4.7
6.0
12.3
12.3
8.1
10.7
Pa
50/125
50/125
62/125
62/125
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.54
1.0
0.25
0.5
0.7/0.8
2.8/3.2
0.4
0.7
0.6
1.2
0.4
0.7
0.6
1.2
0.5
1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
5.49
10.0
79
72
7.1/7.2
14.7/15.2
77
7.8
14.7
77
86
7.9
15.2
75
86
kW
A
4.7
8.5
6.0
11.1
6.8
12.8
6.8
12.8
Pa
50/125
50/125
62/125
62/125
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.54
1.0
0.25
0.5
0.7/0.8
2.9/3.4
0.4
0.7
0.6
1.2
0.4
0.7
0.6
1.2
0.5
1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
5.49
10.6
80
75
7.1/7.2
15.5/15.9
81
7.8
15.5
76
91
7.9
16.0
75
91
kW
A
4.7
8.9
6.0
11.6
6.8
13.4
6.8
13.4
Pa
50/125
50/125
62/125
62/125
kW
A
kW
A
0.54
1.1
0.25
0.6
0.7/0.8
3.1/3.5
0.4
0.8
0.6
1.3
0.4
0.8
0.6
1.3
0.5
1.3
PEH-7
230V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
400V INDOOR FAN INPUT
PEH-7
220V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
380V INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
- 12 -
PEH-5,7,8MYA-EU
Heating
VOLT
ITEM
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
PEH-7
240V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
415V INDOOR FAN INPUT
kW
A
%
A
kW
A
PEH-5MYA-EU PEH-7MYA-EU
PEH-8MYA-EU
PUH-5MYE1-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU
6.5
4.5
6.6
6.2/6.3
12.4
8.6
12.9
13.2/13.6
73
73
71
83
69
83
74
5.5
3.71
5.5
5.1
10.5
7.1
10.5
9.7
Pa
50/125
50/125
62/125
62/125
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.54
1.0
0.25
0.5
0.7/0.8
2.8/3.2
0.4
0.7
0.6
1.2
0.4
0.7
0.6
1.2
0.5
1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
4.5
8.9
73
72
6.2/6.3
13.7/14.2
77
6.5
12.8
73
86
6.6
13.4
71
86
kW
A
3.71
7.4
5.1
10.1
5.5
10.9
5.5
11.0
Pa
50/125
50/125
62/125
62/125
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
0.54
1.0
0.25
0.5
0.7/0.8
2.9/3.4
0.4
0.7
0.6
1.2
0.4
0.7
0.6
1.2
0.5
1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
4.5
9.5
72
75
6.2/6.3
14.5/14.9
81
6.5
13.6
73
91
6.6
14.1
71
91
kW
A
3.71
7.8
5.1
10.6
5.5
11.5
5.5
11.5
Pa
50/125
50/125
62/125
62/125
kW
A
kW
A
0.54
1.1
0.25
0.6
0.7/0.8
3.1/3.5
0.4
0.8
0.6
1.3
0.4
0.8
0.6
1.3
0.5
1.3
PEH-7
230V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
400V INDOOR FAN INPUT
PEH-7
240V COMPRESSOR INPUT
RUN CURRENT
PEH- INDOOR side
5, 8
External static pressure
380V INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
- 13 -
PEH-10,15,20MYA-EU
Cooling
VOLT
PEH10~20
415V
PEH10~20
400V
PEH10~20
380V
ITEM
PEH-10MYA-EU
PEH-15MYA-EU PEH-20MYA-EU
PUH-10MYC2-EU PUH-10MYE1-EU PUH-15MYC2-EU PUH-20MYC2-EU
16.1/16.9
10.1
10.2
20.8/21.8
29.5/30.9
19.0
19.3
37.4/39.3
76
74
74
77
119
82
82
140
2 × 9.15
2 × 6.8
8.6
8.7
2 × 16.1
16.0
16.1
2 × 12.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.0
0.5
1.0
1.0
2.0
0.5
1.2
1.5/2.3
2.7/4.1
2 × 0.5
2 × 1.2
1.5/2.5
2.8/4.7
2 × 0.5
2 × 1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
10.1
19.6
74
85
10.2
19.9
74
85
16.1/16.9
30.6/32.1
76
123
20.8/21.8
38.8/40.8
77
145
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
8.6
16.6
8.7
16.7
2 × 6.8
2 × 12.7
2 × 9.15
2 × 16.75
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.0
0.5
1.0
1.0
2.0
0.5
1.2
1.5/2.3
2.8/4.3
2 × 0.5
2 × 1.2
1.5/2.5
2.9/4.9
2 × 0.5
2 × 1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
10.1
20.7
68
90
10.2
21.0
68
90
16.1/16.9
32.1/33.7
70
131
20.8/21.8
40.9/42.9
71
152
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
8.6
17.5
8.7
17.6
2 × 6.8
2 × 13.3
2 × 9.15
2 × 17.6
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.1
0.5
1.1
1.0
2.1
0.5
1.3
1.5/2.3
2.9/4.5
2 × 0.5
2 × 1.3
1.5/2.5
3.1/5.1
2 × 0.5
2 × 1.3
- 14 -
PEH-10,15,20MYA-EU
Heating
VOLT
PEH10~20
415V
PEH10~20
400V
PEH10~20
380V
ITEM
PEH-10MYA-EU
PEH-15MYA-EU PEH-20MYA-EU
PUH-10MYC2-EU PUH-10MYE1-EU PUH-15MYC2-EU PUH-20MYC2-EU
13.7/14.5
8.3
8.6
16.2/17.2
25.5/26.9
16.1
16.4
31.3/33.2
75
72
73
72
115
82
82
136
2 × 5.6
6.8
7.1
2 × 6.85
13.1
13.2
2 × 10.2
2 × 13.05
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.0
0.5
1.0
1.0
2.0
0.5
1.2
1.5/2.3
2.7/4.1
2 × 0.5
2 × 1.2
1.5/2.5
2.8/4.7
2 × 0.5
2 × 1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
8.3
16.6
72
85
8.6
16.9
73
85
13.7/14.5
26.5/28.0
75
119
16.2/17.2
32.5/34.5
72
141
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
6.8
13.6
7.1
13.7
2 × 5.6
2 × 10.65
2 × 6.85
2 × 13.6
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.0
0.5
1.0
1.0
2.0
0.5
1.2
1.5/2.3
2.8/4.3
2 × 0.5
2 × 1.2
1.5/2.5
2.9/4.9
2 × 0.5
2 × 1.2
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
8.3
17.5
72
90
8.6
17.8
73
90
13.7/14.5
27.8/29.4
75
126
16.2/17.2
34.3/36.3
72
148
COMPRESSOR INPUT
RUN CURRENT
INDOOR side
External static pressure
kW
A
6.8
14.3
7.1
14.4
2 × 5.6
2 × 11.15
2 × 6.85
2 × 14.25
Pa
62/125
62/125
100/200
100/200
INDOOR FAN INPUT
RUN CURRENT
OUTDOOR FAN INPUT
RUN CURRENT
kW
A
kW
A
1.0
2.1
0.5
1.1
1.0
2.1
0.5
1.3
1.5/2.3
2.9/4.5
2 × 0.5
2 × 1.3
1.5/2.5
3.1/5.1
2 × 0.5
2 × 1.3
- 15 -
SELECTION PROCEDURE
1. Model Selection (With actual examples)
First step, to select the approximate model:
Based on the cooling load and the cooling capacity listed in the capacity table, select the applicable model.
Second step, to select the model:
To select the model, the following conditions must be known:
(1) Total cooling load or sensible cooling load
(2) Indoor conditioned temperature (WB*1, DB)
(3) Designed outdoor temperature (DB)*2
(4) Designed air flow
(5) Designed external static pressure (= Wind pressure loss of air duct)*3
Notes:
*1. The correct WB is required since it has a serious effect on the capacity.
*2. The cooling capacity decreases as the outdoor temperature increases. Therefore, the estimated highest
temperature during an air conditioning time frame is the "designed outdoor temperature". However, it is
recommended that the abnormal outdoor temperature which may occur once or twice a year be excluded from
the calculation to avoid selection of an excessively large capacity model.
*3. The wind pressure loss of an air duct should be calculated correctly. If a value having an excessive allowance is
used, an excessively large model will be selected. Moreover, an excessively high air flow will be induced during
actual operation causing the generation of high operating sounds and carry-over of condensed water.
(Step-1) Confirmation of operation range
Confirm that the conditions given above for the model to be selected are within the operation
range listed on Page 37.
(Step-2) Calculation of actual air flow, external static pressure, and fan motor input
Based on the designed air flow and external static pressure, obtain the actual air flow, actual
external static pressure, and fan motor power input from the fan performance table for the model
selected. For an explanation of how to use the fan performance table, see the following
examples.
Example: PE-8MYC, 50Hz
Example 1. (To operate with values near to the designed air flow and external static pressure.)
Condition : Designed air flow 70CMM
Designed external static pressure 60Pa
Calculation : The designed point is A. Therefore, duct
resistance line passing A is dotted line.
Fan Performance Curve 50Hz
Fan speed
(Pa)
(rpm)
Therefore, actual point is B for ∆ connection
450
Recommended Range
Actual air flow = 77CMM
400
For connection
1400
Actual external static pressure = 70Pa
operation line
350
Note:
Duct resustance line is secondary curve.
1300
Total static pressure
B
300
1200
A
250
60Pa
1100
200
For connection
operation line
1000
150
100
Inte
rn
P
al S
900
50
800
0
50
- 16 -
55
60
65
70
Air flow (CMM)
75 77 80
(Step-3) Calculation of net capacity
Based on the indoor conditioned temperature (WB,DB), designed outdoor temperature (DB), and the
actual air flow obtained in Step-2, obtain the gross capacity from the gross capacity tables (pages
18~35). Then, calculate the net capacity from the formula below by using the fan motor input obtained
in Step-2.
Net capacity (kW) = Gross capacity (kW) - Fan motor input (kW)
Example: PE-8MYC
Condition:
Indoor conditioned temp. : 26˚CDB, 19˚CWB
Designed outdoor temp. : 40˚CDB
Actual air flow : 77CMM
Fan motor input : 0.6kW (See P.11)
Calculation :
The sections of the gross capacity table applicable
for the above conditions are shown right.
OUTDOOR DB˚C
INDOOR INDOOR
DB˚C
40.0
WB˚C
Q kW
SHC kW
SHF
T/I kW
19
21.3
9.7
0.46
8.3
26
Factor for Various Air Flow
PE-8MYC-EU
COOLING
At 26˚CDB, 19˚CWB of Indoor,
Q = 21.3, SHC = 9.7, T/I = 8.3
AIR VOLUME
CMM
60
70
80
L/S
1,000
0.976
0.991
0.963
1,167
1.0
1.0
1.0
1,330
1.025
1.009
1.044
CAPACITY
TOTAL INPUT
SHC
Therefore, when air flow is 77(CMM)
Q = 21.3 ✕ (1+(1.025 - 1.0) ✕ 7/10*) ÷ 21.7(kW)
SHC = 9.7 ✕ (1+(1.044 - 1.0) ✕ 7/10*) ÷ 10.0(kW)
T/I = 8.3 ✕ (1+(1.009-1.0))✕ 7/10*) ÷ 8.4(kW)
Note * : 7/10 = (77-70)/(80-70)
Therfore, the net capacity is,
Net total cooling capacity = 21.7 (kw) - 0.6(kW)
= 21.1 (kW)
Net sensible cooling capacity = 10.0 (kW) - 0.6 (kW)
= 9.4 (kW)
2. Efficiency Calculation
• Refrigerant cycle energy efficienty
• System energy efficienty
(1) COP =
Gross total cooling capacity (kW)
Compressor input (kW)
(1) COP =
Net cooling capacity (kW)
Compressor input (kW)
(2) EER =
Gross total cooling capacity (kW)
Total input (kW)
(2) EER =
Net cooling capacity (kW)
Total input (kW)
1kW = 3412Btu/h
Notes:
1. COP : Coefficient of performance
2. EER : Energy efficiency ratio
3. Temperature condition of COP, EER (ARI Standard Ratings)
Indoor entering air temp. : 80˚FDB (=27˚CDB), 66˚FWB(=19˚CWB)
Outdoor entering air temp. : 95˚FDB (=35˚CDB)
4. Total input = Compressor input + Indoor fan motor input + Outdoor fan motor input (page 11).
- 17 -
- 18 -
19.0
24
17.3
21
18.5
17.3
20
23
19.0
24
17.9
18.5
23
22
17.9
17.3
20
22
16.1
19
17.3
18.5
23
21
17.9
22
16.1
19
17.3
15.6
18
21
17.3
21
17.3
17.3
20
20
16.1
15.0
17
19
14.5
16
15.6
16.1
19
18
15.6
14.5
16
18
13.9
15
15.0
15.0
17
17
14.5
13.9
15
16
Q kW
WB ˚C
7.3
8.6
9.9
11.2
12.4
4.8
6.2
7.5
8.9
10.1
12.1
3.7
4.8
6.2
7.4
9.1
10.6
3.8
5.1
6.7
8.0
9.3
11.0
3.9
5.2
6.8
8.3
10.1
4.2
5.5
7.2
SHCkW
20.0
4.8
4.8
4.7
4.7
4.6
4.8
4.8
4.7
4.7
4.6
4.6
4.8
4.7
4.7
4.6
4.6
4.5
4.7
4.6
4.6
4.5
4.5
4.5
4.6
4.5
4.5
4.5
4.4
4.5
4.5
4.4
T/I kW
18.5
18.0
17.4
16.8
16.8
18.5
18.0
17.4
16.8
16.8
15.6
18.0
17.4
16.8
16.8
15.6
15.1
16.8
16.8
15.6
15.1
14.6
14.1
15.6
15.1
14.6
14.1
13.5
14.6
14.1
13.5
Q kW
7.2
8.5
9.6
11.0
12.2
4.7
6.1
7.3
8.7
10.0
12.0
3.6
4.7
6.1
7.3
8.9
10.4
3.7
5.0
6.6
7.9
9.1
10.9
3.8
5.2
6.7
8.2
9.9
4.1
5.4
7.0
SHCkW
25.0
0.39
0.47
0.55
0.66
0.73
0.26
0.34
0.42
0.52
0.59
0.77
0.20
0.27
0.36
0.43
0.57
0.69
0.22
0.30
0.42
0.52
0.62
0.77
0.24
0.34
0.46
0.58
0.73
0.28
0.38
0.52
SHF
AIR VOLUME
CAPACITY
TOTAL INPUT
SHC
PEH-5MYA-EU
COOLING
35
584
0.969
0.989
0.967
CMM
L/S
700
1.0
1.0
1.0
42
SHC:SENSIBLE HEAT CAPACITY
0.38
0.46
0.55
0.65
0.72
0.25
0.33
0.42
0.51
0.59
0.75
0.20
0.27
0.36
0.43
0.57
0.68
0.22
0.29
0.42
0.52
0.62
0.76
0.24
0.34
0.45
0.57
0.72
0.28
0.38
0.52
SHF
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PEH-5MYA-EU
17.9
17.3
16.8
16.2
16.2
17.9
17.3
16.8
16.2
16.2
15.1
17.3
16.8
16.2
16.2
15.1
14.6
16.2
16.2
15.1
14.6
14.1
13.6
15.1
14.6
14.1
13.6
13.1
14.1
13.6
13.1
Q kW
7.0
8.3
9.6
10.8
12.0
4.7
6.0
7.2
8.6
9.8
11.9
3.6
4.6
6.0
7.1
8.8
10.3
3.6
4.8
6.4
7.7
9.0
10.7
3.7
5.0
6.5
7.9
9.7
4.0
5.2
6.9
SHCkW
30.0
0.39
0.48
0.57
0.67
0.74
0.26
0.35
0.43
0.53
0.61
0.79
0.21
0.28
0.37
0.44
0.58
0.70
0.22
0.30
0.42
0.53
0.63
0.79
0.25
0.34
0.46
0.58
0.74
0.28
0.39
0.53
SHF
13.5
14.0
14.4
13.0
13.5
14.0
14.4
15.5
15.5
14.0
14.4
15.5
15.5
16.0
16.6
14.4
15.5
15.5
16.0
16.6
17.1
15.5
15.5
5.0
5.1
5.1
5.0
5.0
5.1
5.1
5.2
5.2
5.1
5.1
5.2
5.2
5.3
5.4
5.1
5.2
5.2
5.3
5.4
5.4
5.2
5.2
17.1
13.0
5.0
5.4
12.6
4.9
16.6
13.5
5.0
5.4
13.0
5.0
16.0
12.6
4.9
5.3
Q kW
T/I kW
OUTDOOR DB˚C
35.0
6.9
8.1
9.3
10.6
11.7
4.6
5.9
7.0
8.4
9.7
11.7
3.4
4.5
5.8
6.9
8.5
10.0
3.5
4.6
6.2
7.5
8.7
10.4
3.6
4.9
6.3
7.8
9.5
3.8
5.0
6.7
SHCkW
0.40
0.49
0.58
0.68
0.75
0.27
0.35
0.44
0.54
0.62
0.81
0.21
0.28
0.37
0.44
0.59
0.71
0.22
0.30
0.43
0.54
0.65
0.80
0.25
0.35
0.47
0.60
0.76
0.28
0.39
0.53
SHF
12.8
13.3
13.7
12.4
12.8
13.3
13.7
14.7
14.7
13.3
13.7
14.7
14.7
15.2
15.7
13.7
14.7
14.7
15.2
15.7
16.3
14.7
14.7
5.4
5.4
5.5
5.3
5.4
5.4
5.5
5.5
5.6
5.4
5.5
5.5
5.6
5.7
5.8
5.5
5.5
5.6
5.7
5.8
5.8
5.5
5.6
16.3
12.4
5.3
5.8
12.0
5.3
15.7
12.8
5.4
5.8
12.4
5.3
15.2
12.0
5.3
5.7
Q kW
T/I kW
834
1.025
1.009
1.028
50
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 125Pa”.)
5.1
5.1
5.0
4.9
4.9
5.1
5.1
5.0
4.9
4.9
4.8
5.1
5.0
4.9
4.9
4.8
4.8
4.9
4.9
4.8
4.8
4.7
4.7
4.8
4.8
4.7
4.7
4.6
4.7
4.7
4.6
T/I kW
Cooling Capacity (Standard Air Flow)
40.0
6.6
7.9
9.1
10.3
11.5
4.3
5.6
6.8
8.2
9.4
11.5
3.3
4.4
5.6
6.7
8.4
9.8
3.3
4.5
6.0
7.4
8.5
10.1
3.4
4.7
6.1
7.6
9.3
3.7
4.9
6.5
SHCkW
0.41
0.50
0.60
0.70
0.78
0.27
0.36
0.45
0.56
0.64
0.84
0.21
0.29
0.38
0.46
0.61
0.74
0.23
0.30
0.44
0.55
0.67
0.82
0.25
0.36
0.48
0.61
0.77
0.29
0.39
0.54
SHF
6.3
6.2
6.1
6.0
6.0
6.3
6.2
6.1
6.0
6.0
5.9
6.2
6.1
6.0
6.0
5.9
5.9
6.0
6.0
5.9
5.9
5.8
5.8
5.9
5.9
5.8
5.8
5.7
5.8
5.8
5.7
T/I kW
15.3
14.8
14.3
13.8
13.8
15.3
14.8
14.3
13.8
13.8
12.9
14.8
14.3
13.8
13.8
12.9
12.5
13.8
13.8
12.9
12.5
12.1
11.7
12.9
12.5
12.1
11.7
11.3
12.1
11.7
11.3
Q kW
46.0
6.5
7.7
9.2
10.6
11.9
4.4
5.6
6.8
8.3
9.5
11.3
3.4
4.4
5.8
6.9
8.4
10.0
3.3
4.6
6.0
7.4
8.6
10.3
3.5
4.7
6.1
7.7
9.3
3.6
4.9
6.4
SHCkW
0.43
0.52
0.64
0.76
0.86
0.28
0.38
0.47
0.60
0.69
0.88
0.23
0.31
0.42
0.50
0.65
0.80
0.24
0.33
0.46
0.59
0.71
0.88
0.27
0.38
0.50
0.65
0.82
0.30
0.42
0.57
SHF
6.7
6.7
6.6
6.5
6.4
6.7
6.7
6.6
6.5
6.4
6.4
6.7
6.6
6.5
6.4
6.4
6.3
6.5
6.4
6.4
6.3
6.3
6.2
6.4
6.3
6.3
6.2
6.1
6.3
6.2
6.1
T/I kW
CAPACITY TABLES
- 19 -
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.3
3.3
9.1
9.1
9.0
9.0
8.9
8.9
8.8
8.8
8.7
8.7
18
19
20
21
22
23
24
25
26
27
4.2
4.2
4.2
4.3
4.3
4.4
4.4
4.4
4.5
4.5
14.3
14.2
14.2
14.1
14.1
14.0
14.0
13.9
13.9
13.8
13.7
13.6
16
17
18
19
20
21
22
23
24
25
26
27
12.3
12.3
12.2
12.2
12.2
12.1
12.1
12.0
12.0
11.9
11.8
3.4
3.5
3.5
3.5
3.5
3.5
3.6
3.6
3.6
3.6
3.7
15.6
15.7
15.8
15.9
15.9
16.0
16.1
16.1
16.2
16.3
16.3
16.4
17.7
17.8
18.0
18.1
18.1
18.2
18.3
18.4
18.5
18.5
18.6
18.6
18.7
Q kW
5.8
5.8
5.7
5.6
5.6
5.6
5.5
5.5
5.4
5.4
5.2
5.1
5.2
T/I kW
HEATING
PEH-5MYA-EU
35
584
0.987
1.021
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
700
1.0
1.0
42
Factor for Various Air Flow
834
1.011
0.983
50
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 125Pa”.)
5.2
5.1
5.1
5.0
5.0
4.9
4.9
4.9
4.8
4.8
4.7
4.7
4.7
T/I kW
4.1
4.1
4.1
4.0
3.9
3.9
3.9
3.8
3.8
3.8
3.8
3.7
3.7
T/I kW
0.0
15.0
12.3
3.4
10.0
16.4
* Q:HEATING CAPACITY
4.6
4.5
4.2
14.3
15
DB ˚C
12.4
3.4
OUTDOOR WB ˚C
10.2
10.2
10.3
10.3
10.4
10.4
10.5
10.5
10.6
10.6
10.7
10.7
10.7
Q kW T/I kW Q kW
3.1
9.1
17
5.0
3.1
9.2
16
INDOOR
3.1
9.2
Q kW
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
15
DB ˚C
INDOOR
PEH-5MYA-EU
Heating Capacity
(Standard Air Flow)
- 20 -
5.6
5.7
5.8
0.89
0.72
0.60
0.48
13.3
11.5
9.6
7.3
18.4
19.3
19.9
21.2
22.0
17
18
19
20
21
18
19
6.3
6.5
6.1
6.3
6.4
6.5
6.8
6.3
6.4
6.5
6.6
6.9
6.4
6.5
0.49
0.25
0.80
0.66
0.50
0.41
0.22
0.89
0.70
0.59
0.48
0.28
0.84
0.74
9.4
5.3
14.9
12.8
10.3
8.7
5.1
17.2
14.2
12.4
10.5
6.7
17.2
15.6
19.3
20.4
21.2
18.7
19.3
20.4
21.2
22.1
23.0
19.3
20.4
21.2
22.1
23.0
24.0
20.4
21.2
5.9
6.1
6.2
5.8
5.9
6.1
6.2
6.3
6.4
5.9
6.1
6.2
6.3
6.4
6.6
6.1
6.2
0.34
0.25
0.79
0.66
0.50
0.41
0.30
0.22
0.87
0.68
0.58
0.47
0.37
0.28
0.84
0.73
5.5
15.2
13.0
10.6
8.9
6.9
5.3
17.3
14.5
12.7
10.7
8.9
6.9
17.7
16.0
19.3
19.9
21.2
22.0
22.8
23.7
19.9
21.2
22.0
22.8
23.7
24.7
21.2
22.0
20
21
22
23
19
20
21
22
23
24
20
21
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
50
830
0.975
0.989
0.964
CMM
L/S
Factor for Various Air Flow
PE-7MYC-EU
PEH-7MYA-EU
0.43
1,000
1.0
1.0
1.0
60
SHC:SENSIBLE HEAT CAPACITY
10.3
6.9
0.41
8.5
20.5
7.0
0.48
10.3
21.3
70
1,167
1.024
1.009
1.040
(
0.44
7.3
35.0
7.2
0.50
9.0
17.9
7.4
0.43
8.4
19.6
7.5
0.50
10.1
20.4
9.9
0.45
7.8
7.7
0.55
11.6
21.2
22.2
7.5
0.66
7.4
0.77
15.1
19.6
13.4
7.3
0.88
16.6
18.8
20.4
7.8
0.29
6.4
22.2
7.7
7.4
0.61
12.0
19.6
0.39
7.3
0.73
13.7
18.8
8.4
7.2
0.94
16.8
17.9
21.2
7.7
0.23
4.8
21.2
7.5
7.3
0.53
9.9
18.8
0.32
7.2
0.69
12.3
17.9
6.4
7.0
0.83
14.2
17.2
20.4
7.4
0.26
5.1
19.6
7.3
7.0
0.62
10.7
17.2
0.36
6.9
0.75
12.4
16.5
6.8
6.8
0.94
14.8
15.8
18.8
7.2
7.0
6.9
6.8
6.7
6.9
6.8
6.7
T/I kW
0.29
0.40
0.55
0.70
0.90
0.33
0.46
0.63
SHF
5.2
6.9
9.0
11.0
13.5
5.5
7.2
9.5
SHCkW
17.9
17.2
16.5
15.8
15.1
16.5
15.8
15.1
Q kW
40.0
7.7
0.51
8.7
17.0
8.0
0.43
8.1
18.7
20.0
)
0.46
8.3
9.7
19.2
8.2
0.56
11.4
20.3
21.2
18.4
8.1
0.67
17.6
8.0
0.80
14.9
18.7
13.1
16.9
7.9
0.92
16.5
17.9
19.5
20.0
8.3
0.30
6.4
21.2
19.2
18.4
8.1
0.51
9.9
19.5
8.2
17.6
8.0
0.63
11.7
18.7
0.40
16.9
7.9
0.75
13.4
17.9
8.2
16.0
7.7
0.96
16.3
17.0
20.3
19.2
8.2
0.23
4.6
18.4
17.6
16.9
16.0
15.5
17.6
16.9
16.0
15.5
14.8
14.2
16.0
15.5
14.8
14.2
13.6
14.8
14.2
13.6
Q kW
20.3
8.1
7.9
0.54
9.6
17.9
0.32
7.7
0.71
12.0
17.0
6.2
7.6
0.85
14.1
16.5
19.5
8.0
0.26
4.9
18.7
7.9
7.6
0.64
10.5
16.5
0.37
7.5
0.77
12.1
15.7
6.6
7.3
0.97
14.5
15.0
17.9
7.7
7.6
7.5
7.3
7.2
7.5
7.3
7.2
T/I kW
0.29
0.41
0.56
0.71
0.93
0.34
0.46
0.64
SHF
5.0
6.8
8.8
10.7
13.2
5.3
6.9
9.1
SHCkW
17.0
16.5
15.7
15.0
14.3
15.7
15.0
14.3
Q kW
In case of “indoor fan external static pressure: ESP = 125Pa”.
If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I value of this table”.
10.1
7.2
0.54
11.9
22.1
23.1
7.0
0.64
6.9
0.75
15.4
20.5
13.7
6.8
0.86
17.0
19.7
21.3
7.3
0.29
6.6
23.1
7.2
6.9
0.60
12.2
20.5
0.38
6.8
0.71
14.0
19.7
8.5
6.7
0.91
17.1
18.7
22.1
7.2
0.23
5.0
22.1
7.0
6.8
0.51
10.1
19.7
0.31
6.7
0.67
12.6
18.7
6.6
6.6
0.82
14.7
18.0
21.3
6.9
0.25
5.2
20.5
6.8
6.7
0.50
9.3
18.7
0.35
6.6
0.62
11.1
18.0
7.0
6.4
0.74
12.7
17.2
19.7
6.3
0.93
15.3
16.5
6.6
6.4
6.3
6.2
6.4
6.3
6.2
T/I kW
6.7
0.40
0.54
0.68
0.88
0.33
0.45
0.62
SHF
OUTDOOR DB˚C
0.29
7.2
9.3
11.3
13.9
5.7
7.4
9.8
SHCkW
30.0
5.3
18.7
18.0
17.2
16.5
15.8
17.2
16.5
15.8
Q kW
T/I:TOTAL INPUT
6.9
24.0
6.6
0.42
10.5
24.7
24
6.8
0.53
12.2
23.0
6.4
0.52
12.3
23.7
23
6.6
6.3
0.62
14.1
22.8
22
0.63
6.8
6.6
13.9
0.38
0.31
22.1
8.7
6.8
6.4
6.1
0.61
11.3
18.7
0.35
6.0
0.73
13.0
17.9
7.1
5.9
6.3
6.1
6.0
5.9
5.8
6.0
5.9
5.8
T/I kW
0.90
0.28
0.39
0.53
0.67
0.86
0.33
0.44
0.61
SHF
15.5
5.4
7.3
9.5
11.5
14.2
5.8
7.7
10.1
SHCkW
25.0
17.2
19.3
5.9
15.8
0.28
18.7
5.8
17.7
5.6
17.9
17.2
16.5
5.7
16
5.6
19.9
0.39
0.53
0.67
5.5
17.9
5.7
19
7.5
9.7
11.8
0.85
17.2
5.6
19.3
17.7
16
14.4
0.32
16.5
Q kW
5.5
T/I kW
18
16.9
15
6.0
0.44
0.61
SHF
18.4
18.4
17
7.9
10.3
SHCkW
17
17.7
16.9
15
16
Q kW
WB ˚C
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PE-7MYC-EU , PEH-7MYA-EU
Cooling Capacity (Standard Air Flow)
46.0
9.3
11.1
12.7
14.4
16.2
6.2
7.9
9.5
11.2
12.9
15.8
4.3
5.9
7.7
9.2
11.5
13.6
4.7
6.3
8.4
10.2
11.8
14.1
4.8
6.5
8.5
10.3
12.9
5.0
6.6
8.9
SHCkW
SHF
0.47
0.58
0.69
0.82
0.96
0.31
0.41
0.52
0.63
0.76
0.99
0.23
0.32
0.44
0.55
0.72
0.88
0.26
0.37
0.52
0.66
0.79
0.99
0.30
0.42
0.57
0.73
0.95
0.34
0.47
0.65
9.0
8.9
8.7
8.6
8.5
9.0
8.9
8.7
8.6
8.5
8.3
8.9
8.7
8.6
8.5
8.3
8.2
8.6
8.5
8.3
8.2
8.1
8.0
8.3
8.2
8.1
8.0
7.9
8.1
8.0
7.9
T/I kW
- 21 -
5.3
5.4
5.5
0.70
0.57
0.46
9.9
21.6
22.5
23.4
24.4
25.3
26.1
22.5
23.4
5.6
5.7
5.4
5.5
5.6
5.7
5.8
6.0
5.5
5.6
5.7
5.8
6.0
6.1
5.6
5.7
0.34
0.25
0.76
0.63
0.50
0.41
0.30
0.23
0.81
0.67
0.56
0.45
0.36
0.28
0.83
0.71
7.7
5.8
15.8
13.6
11.3
9.5
7.3
5.7
17.5
15.1
13.2
11.0
9.2
7.3
18.8
16.8
23.5
20.7
21.7
22.6
23.5
24.5
25.4
21.7
22.6
23.5
24.5
25.4
26.2
22.6
23.5
21
18
19
20
21
22
23
19
20
21
22
23
24
20
21
25.3
26.1
6.0
6.1
0.49
0.41
12.5
10.8
25.4
26.2
23
24
10.7
12.5
14.6
16.7
18.6
7.3
9.1
11.0
13.2
15.0
17.5
5.7
7.3
9.5
11.2
13.5
15.7
5.8
7.6
9.9
11.8
13.8
16.3
5.9
7.9
10.0
12.3
14.8
6.2
8.3
10.6
23.3
24.3
25.2
21.5
22.4
23.3
24.3
25.2
25.9
22.4
23.3
5.3
5.3
5.5
5.6
5.7
5.3
5.5
5.6
5.7
5.8
5.9
5.5
5.6
5.7
5.8
5.9
6.1
5.6
5.7
0.70
0.57
0.46
0.34
0.25
0.76
0.63
0.50
0.40
0.30
0.22
0.81
0.67
0.56
0.41
0.49
0.60
0.71
0.83
0.28
0.36
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
50
830
0.975
0.989
0.964
CMM
L/S
Factor for Various Air Flow
PE-7MYC-EU
PEH-7MYA-EU
25.9
6.1
1,000
1.0
1.0
1.0
60
1,167
1.024
1.009
1.040
70
25.2
5.9
10.7
12.4
14.6
16.6
18.5
7.2
9.1
10.9
13.1
14.9
17.5
5.6
7.2
9.4
11.1
13.5
15.7
5.8
7.6
9.8
11.8
13.7
16.3
5.9
7.8
9.9
12.2
14.7
6.2
8.2
10.6
22.2
23.1
24.1
25.0
21.3
22.2
23.1
24.1
25.0
25.6
22.2
23.1
5.6
5.8
5.9
5.5
5.6
5.8
5.9
6.0
6.1
5.6
5.8
5.9
6.0
6.1
6.2
5.8
5.9
0.46
0.34
0.25
0.76
0.63
0.50
0.40
0.30
0.22
(
21.3
5.5
0.57
0.41
0.49
0.60
0.71
0.83
0.28
0.36
0.45
0.56
0.67
0.81
20.3
5.4
0.70
24.1
25.0
25.6
6.0
6.1
6.2
23.1
22.2
21.3
20.3
19.4
18.4
5.8
0.87
21.3
20.3
19.4
18.4
17.5
19.4
18.4
17.5
10.6
12.4
14.4
16.4
18.3
7.1
9.0
10.9
13.0
14.8
17.4
5.5
7.1
9.2
10.9
13.3
15.5
5.7
7.5
9.7
11.7
13.6
16.1
5.8
7.7
9.9
12.1
14.6
6.1
8.1
10.5
Q kW SHCkW
5.6
5.5
5.4
5.3
5.1
5.4
5.3
5.1
T/I kW
0.27
0.38
0.51
0.66
0.83
0.31
0.44
0.60
SHF
10.0
21.7
22.6
19.9
20.8
21.7
22.6
23.5
24.3
20.8
21.7
22.6
23.5
24.3
25.2
21.7
22.6
5.5
5.6
5.8
5.9
6.0
5.6
5.8
5.9
6.0
6.1
6.3
5.8
5.9
6.0
6.1
6.3
6.5
5.9
6.0
0.70
0.58
0.46
0.34
0.25
0.76
0.63
0.49
0.41
0.50
0.60
0.71
0.82
0.28
0.36
0.45
0.56
0.67
0.82
0.22
0.30
0.40
20.8
5.4
0.87
23.5
24.3
25.2
6.1
6.3
6.5
19.9
19.1
18.2
20.8
5.8
0.27
19.9
19.1
18.2
17.3
19.1
18.2
17.3
10.5
12.4
14.3
16.2
18.0
7.0
8.9
10.8
12.8
14.6
17.4
5.4
7.0
9.1
10.8
13.2
15.4
5.6
7.4
9.7
11.6
13.4
16.0
5.7
7.6
9.8
12.0
14.5
6.0
8.0
10.4
Q kW SHCkW
5.6
5.5
5.4
5.3
5.5
5.4
5.3
T/I kW
0.38
0.51
0.66
0.84
0.31
0.44
0.60
SHF
26
27
6.1
6.2
6.3
0.46
0.34
0.25
)
25
5.9
0.58
0.42
0.51
0.61
0.72
0.83
0.28
0.37
0.46
0.57
0.68
0.83
0.22
0.30
0.40
0.50
0.63
6.7
6.5
6.4
6.3
6.2
6.7
6.5
6.4
6.3
6.2
6.1
6.5
6.4
6.3
6.2
6.1
5.9
24
5.8
0.70
0.77
23
5.7
0.88
(
17.6
17.8
18.0
18.0
18.0
18.1
18.2
18.2
18.2
18.4
18.4
18.8
18.5
6.5
6.5
6.4
6.4
6.3
6.2
6.2
6.1
6.1
6.0
6.0
5.9
5.9
5.3
5.3
5.3
5.3
5.2
5.2
5.2
5.1
5.1
5.1
5.0
5.0
5.0
20.5
20.6
20.8
20.8
20.9
21.0
21.0
21.0
21.0
21.2
21.3
21.7
21.4
7.2
7.2
7.1
7.0
7.0
6.9
6.8
6.7
6.7
6.6
6.6
6.5
6.4
T/I kW
10.0
OUTDOOR WB ˚C
12.7
12.8
13.0
12.9
13.0
13.1
13.1
13.2
13.2
13.3
13.4
13.8
13.5
Q kW T/I kW Q kW
5.0
4.9
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.7
4.7
4.6
4.6
23.6
23.7
23.9
23.9
24.0
24.1
24.1
24.2
24.2
24.4
24.4
24.8
24.6
Q kW
HEATING
50
830
0.980
1.028
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
1,000
1.0
1.0
60
Factor for Various Air Flow
PEH-7MYA-EU
8.0
7.9
7.9
7.8
7.7
7.6
7.6
7.5
7.4
7.3
7.2
7.1
7.0
T/I kW
5.9
5.8
5.8
5.8
5.7
5.7
5.6
5.6
5.5
5.5
5.5
5.4
5.4
T/I kW
0.0
15.0
15.0
15.1
15.4
15.3
15.4
15.5
15.5
15.6
15.6
15.7
15.8
16.1
15.4
Q kW
1,167
1.011
0.98
70
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static pressure: ESP = 125Pa”.
If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I
value of this table”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
10.6
10.6
10.8
10.8
10.8
10.9
22
6.1
11.0
11.0
11.0
11.2
11.3
11.7
11.5
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
21
0.27
20
19
18
17
16
5.9
5.8
5.7
5.6
5.8
5.7
15
DB ˚C
INDOOR
PEH-7MYA-EU
Heating Capacity
(Standard Air Flow)
0.38
0.51
0.66
0.84
0.32
0.44
5.6
SHF T/I kW
0.60
15.0
T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 125Pa”.
If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I value
of this table”.
24.3
5.8
22.4
21.5
20.5
23.3
22.4
21.5
20.5
19.6
18.6
5.2
21.5
20.5
19.6
18.6
17.7
19.6
18.6
17.7
0.87
0.45
5.0
OUTDOOR DB˚C
Q kW SHCkW
5.5
5.3
5.3
5.2
5.1
5.3
5.2
5.1
T/I kW
0.27
0.38
0.51
0.66
0.83
0.31
0.44
0.60
SHF
SHC:SENSIBLE HEAT CAPACITY
24.4
5.8
0.60
14.7
24.5
22
25.3
24.4
23.4
22.5
21.6
20.6
23.4
22.5
21.6
22.6
20.6
19.7
20
11.9
13.8
18.7
21.6
20.6
19.7
18.7
17.8
19.7
18.7
17.8
21.7
19.8
17
5.2
0.87
16.4
0.0
Q kW SHC kW
19
18.8
16
5.5
5.4
5.3
5.2
5.0
5.3
5.2
5.0
0.28
6.0
0.38
0.51
0.66
0.83
0.31
0.44
0.59
T/I kW
20.7
21.7
19
7.9
10.0
12.4
14.8
6.2
8.3
10.6
SHF
18
20.7
18.8
16
18
17.9
15
19.8
19.8
17
17
18.8
16
17.9
Q kW SHCkW
-5.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
15
DB˚C WB˚C
INDOOR
PE-7MYC-EU , PEH-7MYA-EU
(Use for low ambient cooling parts)
Cooling Capacity (Standard Air Flow)
)
- 22 -
26.1
23.5
21
18
27.9
28.8
24
26.1
21
23
25.2
20
27.0
28.8
24
22
27.9
25.2
20
23
24.4
19
27.0
27.9
23
22
27.0
22
26.1
26.1
21
21
25.2
20
24.4
25.2
20
19
24.4
22.7
17
19
22.0
16
23.5
24.4
19
18
23.5
22.0
16
18
21.3
15
22.7
22.7
17
17
22.0
21.3
15
16
Q kW
WB ˚C
11.9
13.8
16.1
18.5
21.0
7.9
10.0
11.9
14.4
16.6
19.2
6.0
8.0
10.4
12.3
14.7
17.4
6.1
8.1
10.7
12.9
15.1
18.1
6.2
8.7
11.1
13.8
16.2
6.6
9.0
11.6
SHCkW
20.0
28.0
7.2
26.2
27.1
28.0
7.0
7.2
25.3
6.9
6.8
24.4
27.1
7.0
6.7
26.2
25.3
24.4
6.9
6.8
6.7
23.6
27.1
7.0
6.5
26.2
25.3
24.4
23.6
22.8
25.3
24.4
23.6
22.8
22.0
21.3
23.6
22.8
22.0
21.3
20.6
22.0
21.3
20.6
Q kW
6.9
6.8
6.7
6.5
6.4
6.8
6.7
6.5
6.4
6.3
6.2
6.5
6.4
6.3
6.2
6.1
6.3
6.2
6.1
T/I kW
COOLING
PEH-8MYA-EU
PE-8MYC-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
11.8
13.5
15.8
18.2
20.7
7.7
9.8
11.6
14.1
16.2
18.7
5.9
7.9
10.2
12.1
14.3
17.0
5.9
7.8
10.4
12.6
14.8
17.7
6.0
8.5
10.9
13.6
15.9
6.4
8.8
11.4
SHCkW
25.0
0.42
0.50
0.60
0.72
0.85
0.27
0.36
0.44
0.56
0.66
0.79
0.22
0.30
0.40
0.50
0.61
0.75
0.23
0.32
0.44
0.55
0.67
0.83
0.26
0.37
0.50
0.64
0.77
0.29
0.41
0.55
SHF
60
1,000
0.976
0.991
0.963
CMM
L/S
1,167
1.0
1.0
1.0
70
SHC:SENSIBLE HEAT CAPACITY
0.41
0.49
0.60
0.71
0.83
0.27
0.36
0.44
0.55
0.66
0.79
0.22
0.30
0.40
0.49
0.60
0.74
0.23
0.32
0.44
0.55
0.67
0.82
0.26
0.37
0.49
0.63
0.76
0.29
0.41
0.55
SHF
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
27.1
26.3
25.4
24.5
23.7
27.1
26.3
25.4
24.5
23.7
22.9
26.3
25.4
24.5
23.7
22.9
22.1
24.5
23.7
22.9
22.1
21.3
20.6
22.9
22.1
21.3
20.6
19.9
21.3
20.6
19.9
Q kW
11.9
13.5
15.6
17.9
20.4
7.5
9.6
11.4
13.9
15.9
18.4
5.7
7.7
10.0
12.0
14.1
16.7
5.7
7.6
10.2
12.3
14.5
17.4
5.9
8.4
10.7
13.3
15.7
6.2
8.5
11.1
SHCkW
0.44
0.51
0.62
0.73
0.86
0.28
0.36
0.45
0.57
0.67
0.80
0.22
0.30
0.41
0.50
0.62
0.76
0.23
0.32
0.44
0.56
0.68
0.84
0.26
0.38
0.50
0.65
0.79
0.29
0.41
0.56
SHF
7.9
7.8
7.6
7.5
7.4
7.9
7.8
7.6
7.5
7.4
7.3
7.8
7.6
7.5
7.4
7.3
7.2
7.5
7.4
7.3
7.2
7.0
6.9
7.3
7.2
7.0
6.9
6.8
7.0
6.9
6.8
T/I kW
26.0
25.3
24.4
23.7
22.8
26.0
25.3
24.4
23.7
22.8
22.0
25.3
24.4
23.7
22.8
22.0
21.3
23.7
22.8
22.0
21.3
20.6
19.9
22.0
21.3
20.6
19.9
19.2
20.6
19.9
19.2
Q kW
OUTDOOR DB˚C
35.0
11.7
13.3
15.4
17.7
19.9
7.2
9.3
11.1
13.5
15.5
17.8
5.5
7.4
9.7
11.7
13.8
16.4
5.6
7.4
9.9
12.0
14.3
17.1
5.7
8.1
10.4
13.1
15.5
5.9
8.2
10.9
SHCkW
0.45
0.53
0.63
0.75
0.87
0.28
0.37
0.46
0.57
0.68
0.81
0.22
0.30
0.41
0.51
0.63
0.77
0.24
0.32
0.45
0.56
0.69
0.86
0.26
0.38
0.50
0.66
0.81
0.29
0.41
0.57
SHF
8.4
8.3
8.1
8.0
7.9
8.4
8.3
8.1
8.0
7.9
7.8
8.3
8.1
8.0
7.9
7.8
7.6
8.0
7.9
7.8
7.6
7.5
7.4
7.8
7.6
7.5
7.4
7.3
7.5
7.4
7.3
T/I kW
25.2
24.3
23.6
22.8
22.0
25.2
24.3
23.6
22.8
22.0
21.3
24.3
23.6
22.8
22.0
21.3
20.6
22.8
22.0
21.3
20.6
19.8
19.1
21.3
20.6
19.8
19.1
18.3
19.8
19.1
18.3
Q kW
1,330
1.025
1.009
1.044
80
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
7.5
7.4
7.2
7.1
7.0
7.5
7.4
7.2
7.1
7.0
6.9
7.4
7.2
7.1
7.0
6.9
6.7
7.1
7.0
6.9
6.7
6.6
6.5
6.9
6.7
6.6
6.5
6.4
6.6
6.5
6.4
T/I kW
30.0
PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYC2-EU)
Cooling Capacity (Standard Air Flow)
40.0
11.7
13.1
15.2
17.3
19.6
7.0
9.1
11.1
13.5
15.5
17.9
5.3
7.3
9.5
11.5
13.6
16.2
5.4
7.2
9.7
11.9
14.0
16.8
5.6
8.0
10.2
12.7
14.9
5.9
8.1
10.5
SHCkW
0.46
0.54
0.64
0.76
0.89
0.28
0.37
0.47
0.59
0.70
0.84
0.22
0.31
0.42
0.52
0.64
0.78
0.24
0.33
0.46
0.58
0.71
0.88
0.26
0.39
0.52
0.67
0.82
0.30
0.42
0.58
SHF
8.9
8.8
8.7
8.6
8.5
8.9
8.8
8.7
8.6
8.5
8.3
8.8
8.7
8.6
8.5
8.3
8.2
8.6
8.5
8.3
8.2
8.1
7.9
8.3
8.2
8.1
7.9
7.8
8.1
7.9
7.8
T/I kW
46.0
SHF
8.7
8.5
8.6
8.7
8.8
8.9
8.6
8.7
8.8
8.9
9.1
9.2
8.8
0.82
0.68
0.53
0.40
0.27
0.90
0.72
0.59
0.46
0.33
0.24
0.80
14.5
12.4
9.9
7.7
5.4
16.4
13.7
11.5
9.4
7.0
5.2
15.6
17.6
18.3
18.9
19.5
20.2
18.3
18.9
19.5
20.2
20.9
21.7
19.5
9.2
0.78
16.9
21.7
9.6
9.1
0.90
18.8
20.9
9.5
9.6
0.28
6.7
23.9
0.48
9.5
0.38
8.8
23.1
11.5
9.3
0.48
10.8
22.4
23.9
9.2
0.61
13.3
21.7
9.3
9.1
0.73
15.2
20.9
0.56
8.9
0.87
17.6
20.2
12.8
9.5
0.22
5.1
23.1
23.1
9.3
0.31
7.0
22.4
0.66
9.2
0.43
9.3
21.7
14.8
9.1
0.53
11.1
20.9
22.4
8.9
0.65
13.2
20.2
7.9
8.6
18.3
0.30
8.5
T/I kW
5.7
0.58
18.9
10.3
SHCkW
0.43
17.6
Q kW
- 23 -
5.9
6.0
5.8
5.9
6.0
6.1
6.2
5.9
0.41
0.29
0.77
0.62
0.48
0.36
0.26
0.82
9.4
6.9
17.0
14.1
11.4
8.9
6.6
18.8
22.9
23.8
22.0
22.9
23.8
24.7
25.6
22.9
16
17
15
16
17
18
19
16
17
6.1
6.2
6.3
6.4
6.1
0.55
0.44
0.33
0.24
0.73
13.5
11.2
8.6
6.5
18.1
24.7
25.6
26.5
27.4
24.7
19
20
21
18
30.8
29.0
28.2
27.3
26.4
30.8
29.0
28.2
27.3
26.4
25.5
29.0
28.2
27.3
26.4
25.5
24.6
27.3
26.4
25.5
24.6
23.8
22.9
25.5
24.6
23.8
22.9
22.0
23.8
22.9
22.0
12.2
14.2
16.7
19.2
21.5
8.2
10.3
12.4
15.0
17.2
20.0
6.3
8.2
10.7
12.7
15.4
18.0
6.4
8.6
11.2
13.4
15.7
18.7
6.6
8.9
11.3
14.1
16.9
6.9
9.3
12.0
Q kW SHC kW
0.0
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
60
1,000
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
PE-8MYC-EU
PEH-8MYA-EU
6.5
6.6
6.7
6.9
6.4
6.5
6.6
6.7
6.9
0.44
0.36
0.27
0.81
0.70
0.59
0.49
0.40
6.0
0.73
0.55
6.5
0.24
6.4
6.4
0.32
0.65
6.3
0.44
6.3
6.0
0.55
0.78
6.0
0.66
6.7
5.9
0.82
0.22
6.3
0.26
6.6
6.0
0.36
0.29
6.0
0.48
6.5
5.9
0.61
0.39
5.8
0.77
6.4
6.0
0.29
0.48
5.9
0.41
6.3
5.8
0.55
0.60
T/I kW
SHF
1,167
1.0
1.0
1.0
70
SHC:SENSIBLE HEAT CAPACITY
6.8
0.39
12.2
31.0
24
19.3
27.4
21
6.7
6.3
0.81
21.6
26.5
20
0.49
6.8
0.26
8.2
31.0
24
14.2
6.7
0.35
10.4
29.2
23
29.2
6.5
0.44
12.5
28.3
22
23
6.4
0.55
15.1
27.4
21
6.5
6.3
0.65
17.3
26.5
20
6.4
6.2
0.79
20.1
25.6
19
0.59
6.7
0.22
6.3
29.2
23
0.70
6.5
0.29
8.2
28.3
22
16.8
6.4
0.39
10.8
27.4
21
28.3
6.3
0.48
12.8
26.5
20
22
6.2
0.61
15.5
25.6
19
6.0
0.66
15.8
23.8
18
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
5.8
15
0.55
T/I kW
SHF
12.1
Q kW SHCkW
-5.0
22.0
DB˚C WB˚C
INDOOR
12.2
14.1
16.7
19.1
21.4
8.1
10.3
12.4
14.9
17.1
19.9
6.3
8.1
10.7
12.7
15.3
17.9
6.4
8.5
11.1
13.4
15.6
18.6
6.5
8.9
11.3
14.0
16.8
6.8
9.3
12.0
6.6
6.7
6.8
7.0
6.5
6.6
6.7
6.8
7.0
0.44
0.35
0.27
0.81
0.70
0.59
0.49
0.40
6.2
0.73
0.55
6.6
0.23
6.5
6.5
0.32
0.65
6.3
0.44
6.3
6.2
0.54
0.78
6.1
0.66
6.8
6.0
0.82
0.22
6.3
0.26
6.7
6.2
0.36
0.29
6.1
0.48
6.6
6.0
0.62
0.39
5.9
0.77
6.5
6.1
0.29
0.48
6.0
0.41
6.3
5.9
0.55
0.60
T/I kW
SHF
0.22
0.78
0.65
0.55
0.44
0.35
0.27
0.81
0.70
0.59
0.49
0.40
6.2
19.6
16.9
14.8
12.2
10.2
8.0
21.3
18.9
16.5
14.0
12.1
28.7
25.2
26.1
27.0
27.8
28.7
30.1
26.1
27.0
27.8
28.7
30.1
0.73
17.7
24.4
0.29
0.23
6.3
27.0
8.1
0.32
8.3
26.1
27.8
0.43
10.9
25.2
0.39
0.54
13.2
24.4
10.6
0.66
15.5
23.5
27.0
0.81
18.5
22.7
0.48
0.25
6.4
25.2
12.6
0.36
8.8
24.4
26.1
0.48
11.2
23.5
0.60
0.61
13.9
22.7
15.1
0.76
25.2
0.29
6.8
16.6
21.8
0.40
9.2
22.7
23.5
0.54
11.9
SHF
21.8
Q kW SHCkW
10.0
0.29
0.21
0.78
0.65
0.55
0.44
0.35
0.27
0.82
0.70
0.59
0.49
0.41
8.0
6.1
19.4
16.7
14.6
12.1
10.1
7.9
21.1
18.7
16.3
13.9
12.0
28.6
25.0
25.8
26.7
27.7
28.6
29.5
25.8
26.7
27.7
28.6
29.5
7.0
6.6
6.7
6.8
6.9
7.0
7.2
6.7
6.8
6.9
7.0
7.2
0.73
17.6
24.1
6.4
27.7
0.23
6.2
26.7
6.8
6.9
0.32
8.2
25.8
6.7
0.39
0.43
10.8
25.0
6.6
10.5
0.54
13.0
24.1
6.4
26.7
0.66
15.3
23.3
6.3
6.8
0.81
18.3
22.4
6.2
0.48
0.25
6.3
25.0
6.6
12.5
0.36
8.7
24.1
6.4
25.8
0.48
11.1
23.3
6.3
6.7
0.62
13.8
22.4
6.2
0.60
0.76
21.6
6.0
14.9
0.29
6.7
16.4
23.3
6.3
25.0
0.40
9.1
22.4
6.2
6.6
0.54
11.7
SHF
21.6
Q kW SHCkW
6.0
T/I kW
15.0
14.2
14.1
17
18
19
20
21
22
23
24
25
26
27
6.5
6.3
6.4
6.5
6.6
7.0
6.4
6.5
6.6
7.0
7.0
7.5
7.3
7.2
7.1
7.0
7.5
7.3
7.2
7.1
7.0
7.0
7.3
7.2
7.1
7.0
7.0
6.6
80
1,330
1.025
1.009
1.044
6.7
6.7
6.6
6.6
6.5
6.4
6.4
6.3
6.3
6.2
6.2
6.1
6.1
23.7
23.8
24
24
24.1
24.2
24.2
24.3
24.3
24.4
24.5
24.6
24.6
7.4
7.4
7.3
7.2
7.2
7.1
7.0
6.9
6.9
6.8
6.8
7.0
6.6
T/I kW
10.0
)
26.8
26.9
27.1
27.1
27.2
27.3
27.3
27.4
27.4
27.6
27.6
27.7
27.8
Q kW
HEATING
PEH-8MYA-EU
60
1,000
0.989
1.010
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
70
1,167
1.0
1.0
5.6
6.1
6.0
6.0
6.0
5.9
5.9
5.8
5.8
5.7
5.7
5.7
5.6
1,330
1.011
0.987
80
8.2
8.1
8.1
8.0
7.9
7.8
7.8
7.7
7.6
7.5
7.4
7.3
7.2
T/I kW
15.0
18.2
18.3
18.6
18.5
18.6
18.7
18.7
18.8
18.8
18.9
19
19
T/I kW
0.0
19.1
Factor for Various Air Flow
(
20.8
21
21.2
21.2
21.2
21.3
21.4
21.4
21.4
21.6
21.6
21.7
21.7
5.5
5.5
5.5
5.5
5.4
5.4
5.4
5.3
5.3
5.3
5.2
5.2
5.2
OUTDOOR WB ˚C
15.9
16
16.2
16.1
16.2
16.3
16.3
16.4
16.4
16.5
16.6
16.7
16.7
Q kW T/I kW Q kW
5.1
13.8
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.9
4.9
13.8
14
14
14
14.2
14.2
14.4
4.8
4.8
Q kW
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static
pressure: ESP = 62/125Pa”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
14.5
16
6.4
7.1
14.6
15
6.3
14.7
DB ˚C
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
T/I kW
INDOOR
PEH-8MYA-EU
(combined with PUH-8MYC2-EU)
Heating Capacity (Standard Air Flow)
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
30.5
28.9
28.1
27.2
26.3
30.5
28.9
28.1
27.2
26.3
25.4
28.9
28.1
27.2
26.3
25.4
24.5
27.2
26.3
25.4
24.5
23.7
22.8
25.4
24.5
23.7
22.8
21.9
23.7
22.8
21.9
Q kW SHCkW
5.0
OUTDOOR DB˚C
PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYC2-EU)
(Use for low ambient cooling parts)
Cooling Capacity (Standard Air Flow)
- 24 -
26.1
23.5
21
18
27.9
28.8
24
26.1
21
23
25.2
20
27.0
28.8
24
22
27.9
25.2
20
23
24.4
19
27.0
27.9
23
22
27.0
22
26.1
26.1
21
21
25.2
20
24.4
25.2
20
19
24.4
22.7
17
19
22.0
16
23.5
24.4
19
18
23.5
22.0
16
18
21.3
15
22.7
22.7
17
17
22.0
21.3
15
16
Q kW
WB ˚C
11.9
13.8
16.1
18.5
21.0
7.9
10.0
11.9
14.4
16.6
19.2
6.0
8.0
10.4
12.3
14.7
17.4
6.1
8.1
10.7
12.9
15.1
18.1
6.2
8.7
11.1
13.8
16.2
6.6
9.0
11.6
SHCkW
20.0
28.0
7.2
26.2
27.1
28.0
7.0
7.2
25.3
6.9
6.8
24.4
27.1
7.0
6.7
26.2
25.3
24.4
6.9
6.8
6.7
23.6
27.1
7.0
6.5
26.2
25.3
24.4
23.6
22.8
25.3
24.4
23.6
22.8
22.0
21.3
23.6
22.8
22.0
21.3
20.6
22.0
21.3
20.6
Q kW
6.9
6.8
6.7
6.5
6.4
6.8
6.7
6.5
6.4
6.3
6.2
6.5
6.4
6.3
6.2
6.1
6.3
6.2
6.1
T/I kW
COOLING
PEH-8MYA-EU
PE-8MYC-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
11.8
13.5
15.8
18.2
20.7
7.7
9.8
11.6
14.1
16.2
18.7
5.9
7.9
10.2
12.1
14.3
17.0
5.9
7.8
10.4
12.6
14.8
17.7
6.0
8.5
10.9
13.6
15.9
6.4
8.8
11.4
SHCkW
25.0
0.42
0.50
0.60
0.72
0.85
0.27
0.36
0.44
0.56
0.66
0.79
0.22
0.30
0.40
0.50
0.61
0.75
0.23
0.32
0.44
0.55
0.67
0.83
0.26
0.37
0.50
0.64
0.77
0.29
0.41
0.55
SHF
60
1,000
0.976
0.991
0.963
CMM
L/S
1,167
1.0
1.0
1.0
70
SHC:SENSIBLE HEAT CAPACITY
0.41
0.49
0.60
0.71
0.83
0.27
0.36
0.44
0.55
0.66
0.79
0.22
0.30
0.40
0.49
0.60
0.74
0.23
0.32
0.44
0.55
0.67
0.82
0.26
0.37
0.49
0.63
0.76
0.29
0.41
0.55
SHF
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
27.1
26.3
25.4
24.5
23.7
27.1
26.3
25.4
24.5
23.7
22.9
26.3
25.4
24.5
23.7
22.9
22.1
24.5
23.7
22.9
22.1
21.3
20.6
22.9
22.1
21.3
20.6
19.9
21.3
20.6
19.9
Q kW
11.9
13.5
15.6
17.9
20.4
7.5
9.6
11.4
13.9
15.9
18.4
5.7
7.7
10.0
12.0
14.1
16.7
5.7
7.6
10.2
12.3
14.5
17.4
5.9
8.4
10.7
13.3
15.7
6.2
8.5
11.1
SHCkW
0.44
0.51
0.62
0.73
0.86
0.28
0.36
0.45
0.57
0.67
0.80
0.22
0.30
0.41
0.50
0.62
0.76
0.23
0.32
0.44
0.56
0.68
0.84
0.26
0.38
0.50
0.65
0.79
0.29
0.41
0.56
SHF
7.9
7.8
7.6
7.5
7.4
7.9
7.8
7.6
7.5
7.4
7.3
7.8
7.6
7.5
7.4
7.3
7.2
7.5
7.4
7.3
7.2
7.0
6.9
7.3
7.2
7.0
6.9
6.8
7.0
6.9
6.8
T/I kW
26.0
25.3
24.4
23.7
22.8
26.0
25.3
24.4
23.7
22.8
22.0
25.3
24.4
23.7
22.8
22.0
21.3
23.7
22.8
22.0
21.3
20.6
19.9
22.0
21.3
20.6
19.9
19.2
20.6
19.9
19.2
Q kW
OUTDOOR DB˚C
35.0
11.7
13.3
15.4
17.7
19.9
7.2
9.3
11.1
13.5
15.5
17.8
5.5
7.4
9.7
11.7
13.8
16.4
5.6
7.4
9.9
12.0
14.3
17.1
5.7
8.1
10.4
13.1
15.5
5.9
8.2
10.9
SHCkW
0.45
0.53
0.63
0.75
0.87
0.28
0.37
0.46
0.57
0.68
0.81
0.22
0.30
0.41
0.51
0.63
0.77
0.24
0.32
0.45
0.56
0.69
0.86
0.26
0.38
0.50
0.66
0.81
0.29
0.41
0.57
SHF
8.4
8.3
8.1
8.0
7.9
8.4
8.3
8.1
8.0
7.9
7.8
8.3
8.1
8.0
7.9
7.8
7.6
8.0
7.9
7.8
7.6
7.5
7.4
7.8
7.6
7.5
7.4
7.3
7.5
7.4
7.3
T/I kW
25.2
24.3
23.6
22.8
22.0
25.2
24.3
23.6
22.8
22.0
21.3
24.3
23.6
22.8
22.0
21.3
20.6
22.8
22.0
21.3
20.6
19.8
19.1
21.3
20.6
19.8
19.1
18.3
19.8
19.1
18.3
Q kW
1,330
1.025
1.009
1.044
80
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
7.5
7.4
7.2
7.1
7.0
7.5
7.4
7.2
7.1
7.0
6.9
7.4
7.2
7.1
7.0
6.9
6.7
7.1
7.0
6.9
6.7
6.6
6.5
6.9
6.7
6.6
6.5
6.4
6.6
6.5
6.4
T/I kW
30.0
PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYE1-EU)
Cooling Capacity (Standard Air Flow)
40.0
11.7
13.1
15.2
17.3
19.6
7.0
9.1
11.1
13.5
15.5
17.9
5.3
7.3
9.5
11.5
13.6
16.2
5.4
7.2
9.7
11.9
14.0
16.8
5.6
8.0
10.2
12.7
14.9
5.9
8.1
10.5
SHCkW
0.46
0.54
0.64
0.76
0.89
0.28
0.37
0.47
0.59
0.70
0.84
0.22
0.31
0.42
0.52
0.64
0.78
0.24
0.33
0.46
0.58
0.71
0.88
0.26
0.39
0.52
0.67
0.82
0.30
0.42
0.58
SHF
8.9
8.8
8.7
8.6
8.5
8.9
8.8
8.7
8.6
8.5
8.3
8.8
8.7
8.6
8.5
8.3
8.2
8.6
8.5
8.3
8.2
8.1
7.9
8.3
8.2
8.1
7.9
7.8
8.1
7.9
7.8
T/I kW
46.0
SHF
8.7
8.5
8.6
8.7
8.8
8.9
8.6
8.7
8.8
8.9
9.1
9.2
8.8
0.82
0.68
0.53
0.40
0.27
0.90
0.72
0.59
0.46
0.33
0.24
0.80
14.5
12.4
9.9
7.7
5.4
16.4
13.7
11.5
9.4
7.0
5.2
15.6
17.6
18.3
18.9
19.5
20.2
18.3
18.9
19.5
20.2
20.9
21.7
19.5
9.2
0.78
16.9
21.7
9.6
9.1
0.90
18.8
20.9
9.5
9.6
0.28
6.7
23.9
0.48
9.5
0.38
8.8
23.1
11.5
9.3
0.48
10.8
22.4
23.9
9.2
0.61
13.3
21.7
9.3
9.1
0.73
15.2
20.9
0.56
8.9
0.87
17.6
20.2
12.8
9.5
0.22
5.1
23.1
23.1
9.3
0.31
7.0
22.4
0.66
9.2
0.43
9.3
21.7
14.8
9.1
0.53
11.1
20.9
22.4
8.9
0.65
13.2
20.2
7.9
8.6
18.3
0.30
8.5
T/I kW
5.7
0.58
18.9
10.3
SHCkW
0.43
17.6
Q kW
- 25 -
5.9
6.0
5.8
5.9
6.0
6.1
6.2
5.9
0.41
0.29
0.77
0.62
0.48
0.36
0.26
0.82
9.4
6.9
17.0
14.1
11.4
8.9
6.6
18.8
22.9
23.8
22.0
22.9
23.8
24.7
25.6
22.9
16
17
15
16
17
18
19
16
17
6.1
6.2
6.3
6.4
6.1
0.55
0.44
0.33
0.24
0.73
13.5
11.2
8.6
6.5
18.1
24.7
25.6
26.5
27.4
24.7
19
20
21
18
30.8
29.0
28.2
27.3
26.4
30.8
29.0
28.2
27.3
26.4
25.5
29.0
28.2
27.3
26.4
25.5
24.6
27.3
26.4
25.5
24.6
23.8
22.9
25.5
24.6
23.8
22.9
22.0
23.8
22.9
22.0
12.2
14.2
16.7
19.2
21.5
8.2
10.3
12.4
15.0
17.2
20.0
6.3
8.2
10.7
12.7
15.4
18.0
6.4
8.6
11.2
13.4
15.7
18.7
6.6
8.9
11.3
14.1
16.9
6.9
9.3
12.0
Q kW SHC kW
0.0
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
60
1,000
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
PE-8MYC-EU
PEH-8MYA-EU
6.5
6.6
6.7
6.9
6.4
6.5
6.6
6.7
6.9
0.44
0.36
0.27
0.81
0.70
0.59
0.49
0.40
6.0
0.73
0.55
6.5
0.24
6.4
6.4
0.32
0.65
6.3
0.44
6.3
6.0
0.55
0.78
6.0
0.66
6.7
5.9
0.82
0.22
6.3
0.26
6.6
6.0
0.36
0.29
6.0
0.48
6.5
5.9
0.61
0.39
5.8
0.77
6.4
6.0
0.29
0.48
5.9
0.41
6.3
5.8
0.55
0.60
T/I kW
SHF
1,167
1.0
1.0
1.0
70
SHC:SENSIBLE HEAT CAPACITY
6.8
0.39
12.2
31.0
24
19.3
27.4
21
6.7
6.3
0.81
21.6
26.5
20
0.49
6.8
0.26
8.2
31.0
24
14.2
6.7
0.35
10.4
29.2
23
29.2
6.5
0.44
12.5
28.3
22
23
6.4
0.55
15.1
27.4
21
6.5
6.3
0.65
17.3
26.5
20
6.4
6.2
0.79
20.1
25.6
19
0.59
6.7
0.22
6.3
29.2
23
0.70
6.5
0.29
8.2
28.3
22
16.8
6.4
0.39
10.8
27.4
21
28.3
6.3
0.48
12.8
26.5
20
22
6.2
0.61
15.5
25.6
19
6.0
0.66
15.8
23.8
18
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
5.8
15
0.55
T/I kW
SHF
12.1
Q kW SHCkW
-5.0
22.0
DB˚C WB˚C
INDOOR
12.2
14.1
16.7
19.1
21.4
8.1
10.3
12.4
14.9
17.1
19.9
6.3
8.1
10.7
12.7
15.3
17.9
6.4
8.5
11.1
13.4
15.6
18.6
6.5
8.9
11.3
14.0
16.8
6.8
9.3
12.0
6.6
6.7
6.8
7.0
6.5
6.6
6.7
6.8
7.0
0.44
0.35
0.27
0.81
0.70
0.59
0.49
0.40
6.2
0.73
0.55
6.6
0.23
6.5
6.5
0.32
0.65
6.3
0.44
6.3
6.2
0.54
0.78
6.1
0.66
6.8
6.0
0.82
0.22
6.3
0.26
6.7
6.2
0.36
0.29
6.1
0.48
6.6
6.0
0.62
0.39
5.9
0.77
6.5
6.1
0.29
0.48
6.0
0.41
6.3
5.9
0.55
0.60
T/I kW
SHF
0.22
0.78
0.65
0.55
0.44
0.35
0.27
0.81
0.70
0.59
0.49
0.40
6.2
19.6
16.9
14.8
12.2
10.2
8.0
21.3
18.9
16.5
14.0
12.1
28.7
25.2
26.1
27.0
27.8
28.7
30.1
26.1
27.0
27.8
28.7
30.1
0.73
17.7
24.4
0.29
0.23
6.3
27.0
8.1
0.32
8.3
26.1
27.8
0.43
10.9
25.2
0.39
0.54
13.2
24.4
10.6
0.66
15.5
23.5
27.0
0.81
18.5
22.7
0.48
0.25
6.4
25.2
12.6
0.36
8.8
24.4
26.1
0.48
11.2
23.5
0.60
0.61
13.9
22.7
15.1
0.76
25.2
0.29
6.8
16.6
21.8
0.40
9.2
22.7
23.5
0.54
11.9
SHF
21.8
Q kW SHCkW
10.0
0.29
0.21
0.78
0.65
0.55
0.44
0.35
0.27
0.82
0.70
0.59
0.49
0.41
8.0
6.1
19.4
16.7
14.6
12.1
10.1
7.9
21.1
18.7
16.3
13.9
12.0
28.6
25.0
25.8
26.7
27.7
28.6
29.5
25.8
26.7
27.7
28.6
29.5
7.0
6.6
6.7
6.8
6.9
7.0
7.2
6.7
6.8
6.9
7.0
7.2
0.73
17.6
24.1
6.4
27.7
0.23
6.2
26.7
6.8
6.9
0.32
8.2
25.8
6.7
0.39
0.43
10.8
25.0
6.6
10.5
0.54
13.0
24.1
6.4
26.7
0.66
15.3
23.3
6.3
6.8
0.81
18.3
22.4
6.2
0.48
0.25
6.3
25.0
6.6
12.5
0.36
8.7
24.1
6.4
25.8
0.48
11.1
23.3
6.3
6.7
0.62
13.8
22.4
6.2
0.60
0.76
21.6
6.0
14.9
0.29
6.7
16.4
23.3
6.3
25.0
0.40
9.1
22.4
6.2
6.6
0.54
11.7
SHF
21.6
Q kW SHCkW
6.0
T/I kW
15.0
14.2
14.1
17
18
19
20
21
22
23
24
25
26
27
6.5
6.3
6.4
6.5
6.6
7.0
6.4
6.5
6.6
7.0
7.0
7.5
7.3
7.2
7.1
7.0
7.5
7.3
7.2
7.1
7.0
7.0
7.3
7.2
7.1
7.0
7.0
6.6
80
1,330
1.025
1.009
1.044
6.7
6.7
6.6
6.6
6.5
6.4
6.4
6.3
6.3
6.2
6.2
6.1
6.1
23.7
23.8
24
24
24.1
24.2
24.2
24.3
24.3
24.4
24.5
24.6
24.6
7.4
7.4
7.3
7.2
7.2
7.1
7.0
6.9
6.9
6.8
6.8
7.0
6.6
T/I kW
10.0
)
26.8
26.9
27.1
27.1
27.2
27.3
27.3
27.4
27.4
27.6
27.6
27.7
27.8
Q kW
HEATING
PEH-8MYA-EU
60
1,000
0.989
1.010
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
70
1,167
1.0
1.0
5.6
6.1
6.0
6.0
6.0
5.9
5.9
5.8
5.8
5.7
5.7
5.7
5.6
1,330
1.011
0.987
80
8.2
8.1
8.1
8.0
7.9
7.8
7.8
7.7
7.6
7.5
7.4
7.3
7.2
T/I kW
15.0
18.2
18.3
18.6
18.5
18.6
18.7
18.7
18.8
18.8
18.9
19
19
T/I kW
0.0
19.1
Factor for Various Air Flow
(
20.8
21
21.2
21.2
21.2
21.3
21.4
21.4
21.4
21.6
21.6
21.7
21.7
5.5
5.5
5.5
5.5
5.4
5.4
5.4
5.3
5.3
5.3
5.2
5.2
5.2
OUTDOOR WB ˚C
15.9
16
16.2
16.1
16.2
16.3
16.3
16.4
16.4
16.5
16.6
16.7
16.7
Q kW T/I kW Q kW
5.1
13.8
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.9
4.9
13.8
14
14
14
14.2
14.2
14.4
4.8
4.8
Q kW
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static
pressure: ESP = 62/125Pa”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
14.5
16
6.4
7.1
14.6
15
6.3
14.7
DB ˚C
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
T/I kW
INDOOR
PEH-8MYA-EU
(combined with PUH-8MYE1-EU)
Heating Capacity (Standard Air Flow)
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
30.5
28.9
28.1
27.2
26.3
30.5
28.9
28.1
27.2
26.3
25.4
28.9
28.1
27.2
26.3
25.4
24.5
27.2
26.3
25.4
24.5
23.7
22.8
25.4
24.5
23.7
22.8
21.9
23.7
22.8
21.9
Q kW SHCkW
5.0
OUTDOOR DB˚C
PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8ME1-EU)
(Use for low ambient cooling parts)
Cooling Capacity (Standard Air Flow)
- 26 9.1
0.70
23.6
33.6
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
80
1,330
0.977
0.991
0.968
CMM
L/S
Factor for Various Air Flow
PE-10MYC-EU
PEH-10MYA-EU
0.41
1,550
1.0
1.0
1.0
90
SHC:SENSIBLE HEAT CAPACITY
15.1
14.8
0.41
10.0
9.9
0.50
17.3
34.6
35.7
9.8
0.60
9.6
0.72
23.2
32.4
20.1
9.5
0.80
26.0
32.4
33.5
10.0
9.9
9.8
9.6
9.5
9.4
9.9
9.8
9.6
9.5
9.4
9.3
9.6
9.5
9.4
9.3
9.2
9.2
9.4
9.3
9.2
9.2
9.1
9.2
9.2
9.1
T/I kW
0.28
0.36
0.46
0.58
0.65
0.82
0.22
0.30
0.41
0.48
0.63
0.76
0.23
0.31
0.45
0.55
0.68
0.84
0.27
0.37
0.49
0.63
0.80
0.29
0.42
0.55
SHF
9.9
12.6
15.3
18.6
21.1
24.6
7.6
10.0
13.1
15.6
19.0
22.2
7.6
10.2
13.4
16.1
19.1
22.8
8.1
10.8
13.8
17.2
20.8
8.2
11.3
14.5
SHCkW
35.0
14.4
0.42
10.7
10.6
0.51
16.8
33.1
34.2
10.4
0.61
10.3
0.73
22.7
31.0
19.6
10.2
0.82
25.3
31.0
32.0
10.7
0.28
10.6
9.6
0.37
34.2
12.2
10.4
0.46
14.8
32.0
33.1
10.3
10.2
10.1
10.6
10.4
10.3
10.2
10.1
10.0
10.3
10.2
10.1
10.0
9.9
9.8
10.1
10.0
9.9
9.8
9.7
9.9
9.8
9.7
T/I kW
0.59
0.67
0.84
0.22
0.30
0.41
0.48
0.64
0.78
0.24
0.32
0.45
0.56
0.69
0.86
0.27
0.38
0.50
0.64
0.81
0.29
0.42
0.56
SHF
18.2
20.7
24.2
7.4
9.6
12.6
15.0
18.5
21.7
7.3
9.8
13.1
15.6
18.7
22.3
7.8
10.5
13.3
16.7
20.4
7.9
10.9
14.0
SHCkW
31.0
31.0
28.8
33.1
32.0
31.0
31.0
28.8
27.9
31.0
31.0
28.8
27.9
26.9
26.0
28.8
27.9
26.9
26.0
25.1
26.9
26.0
25.1
Q kW
OUTDOOR DB˚C
35.7
34.6
33.5
32.4
32.4
30.1
34.6
33.5
32.4
32.4
30.1
29.1
32.4
32.4
30.1
29.1
28.1
27.1
30.1
29.1
28.1
27.1
26.1
28.1
27.1
26.1
Q kW
30.0
100
1,660
1.035
1.005
1.037
40.0
14.0
0.43
11.5
11.4
0.52
16.4
31.4
32.5
11.2
0.63
11.1
0.76
22.3
29.4
19.1
11.0
0.85
25.1
29.4
30.4
11.5
0.29
9.3
11.4
32.5
0.38
11.2
0.48
14.5
30.4
11.8
11.1
0.61
17.8
29.4
31.4
11.0
10.9
11.4
11.2
11.1
11.0
10.9
10.8
11.1
11.0
10.9
10.8
10.7
10.6
10.9
10.8
10.7
10.6
10.5
10.7
10.6
10.5
T/I kW
0.69
0.86
0.22
0.31
0.42
0.50
0.66
0.80
0.24
0.32
0.46
0.58
0.71
0.88
0.27
0.38
0.51
0.66
0.83
0.30
0.43
0.57
SHF
20.2
23.6
7.1
9.3
12.3
14.7
18.0
21.2
7.0
9.5
12.6
15.3
18.2
21.8
7.5
10.1
13.0
16.3
19.9
7.6
10.5
13.6
SHCkW
29.4
27.3
31.4
30.4
29.4
29.4
27.3
26.5
29.4
29.4
27.3
26.5
25.6
24.7
27.3
26.5
25.6
24.7
23.9
25.6
24.7
23.9
Q kW
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
9.4
36.9
8.9
0.40
15.4
38.0
24
9.3
0.49
17.6
35.9
8.5
0.49
17.9
36.9
23
9.2
0.59
20.3
8.7
0.58
20.8
35.8
22
34.7
8.6
0.70
24.1
34.6
21
9.0
0.79
26.5
33.6
8.5
0.78
27.0
9.4
9.3
0.27
0.36
10.1
12.8
36.9
9.2
9.1
9.0
8.9
35.9
0.44
0.56
0.64
9.3
9.2
9.1
9.0
8.9
8.8
9.1
9.0
8.9
8.8
8.7
8.6
8.9
8.8
8.7
8.6
8.5
8.7
8.6
8.5
T/I kW
8.8
34.6
20
0.35
15.4
18.9
21.4
0.80
0.22
0.30
0.40
0.48
0.62
0.75
0.23
0.31
0.44
0.54
0.67
0.83
0.27
0.37
0.49
0.63
0.78
0.29
0.42
0.55
SHF
34.7
33.6
33.6
24.9
7.8
10.3
13.5
16.0
19.4
22.7
7.8
10.5
13.8
16.4
19.5
23.3
8.3
11.1
14.2
17.6
21.2
8.5
11.7
14.8
SHCkW
25.0
8.7
8.6
8.5
8.4
35.9
8.8
31.2
34.7
33.6
33.6
31.2
8.7
8.4
8.5
8.4
30.2
33.6
8.6
8.3
33.6
31.2
30.2
29.1
28.1
31.2
30.2
29.1
28.1
27.0
29.1
28.1
27.0
Q kW
8.5
8.4
8.3
8.3
8.2
8.4
8.3
8.3
8.2
8.1
8.3
8.2
8.1
T/I kW
8.9
38.0
24
13.0
0.44
0.55
0.63
0.79
0.22
0.29
0.40
0.47
0.61
0.74
0.23
0.31
0.44
0.54
0.66
0.82
0.26
0.36
0.48
0.62
0.77
0.29
0.41
0.54
SHF
0.27
36.9
23
15.7
19.1
21.7
25.3
8.0
10.4
13.7
16.2
19.7
23.0
8.1
10.8
14.1
16.8
19.9
23.7
8.4
11.3
14.4
17.8
21.5
8.7
11.9
15.1
SHCkW
10.3
35.8
34.6
20
22
32.1
19
34.6
36.9
23
21
35.8
22
32.1
19
34.6
31.1
18
21
34.6
21
34.6
34.6
20
20
32.1
30.0
17
19
28.9
16
31.1
32.1
19
18
31.1
28.9
16
18
27.8
15
30.0
30.0
17
17
28.9
27.8
15
16
Q kW
WB ˚C
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYC2-EU)
Cooling Capacity (Standard Air Flow)
12.0
12.1
12.2
11.7
11.8
12.0
12.1
12.3
12.4
11.8
12.0
12.1
12.3
12.4
0.31
0.23
0.89
0.71
0.62
0.49
0.38
0.29
0.89
0.78
0.65
0.53
0.44
9.0
6.7
22.8
19.5
17.1
14.0
11.3
8.8
24.5
21.6
18.5
15.7
13.4
29.5
25.7
27.6
27.6
28.6
29.5
30.5
27.6
27.6
28.6
29.5
30.5
12.0
20.6
24.9
28.6
11.8
0.24
6.7
27.6
11.8
11.7
0.33
9.1
27.6
0.43
11.6
0.48
12.2
25.7
11.9
11.5
0.59
14.8
24.9
27.6
11.4
0.73
17.6
24.1
11.7
11.7
0.91
21.2
23.3
0.52
11.6
0.28
7.1
25.7
14.2
11.5
0.39
9.7
24.9
27.6
11.4
0.52
12.5
24.1
11.6
11.3
0.67
15.7
23.3
0.68
11.5
0.85
19.2
22.5
17.5
11.4
0.30
7.2
24.1
25.7
11.3
0.43
10.0
23.3
0.83
T/I kW
SHF
0.58
13.1
22.5
46.0
SHCkW
Q kW
- 27 -
0.39
0.28
0.74
0.59
0.46
0.35
0.25
0.79
0.63
0.52
0.42
0.31
0.22
0.69
12.3
9.1
22.0
18.4
14.8
11.7
8.8
24.4
20.6
17.6
14.7
11.3
8.6
23.5
31.1
32.5
29.7
31.1
32.5
33.9
35.3
31.1
32.5
33.9
35.3
36.7
38.1
33.9
16
17
15
16
17
18
19
16
17
18
19
20
21
18
0.45
0.39
18.5
16.0
40.9
40.5
24
0.66
25.0
38.1
21
23
0.76
28.0
36.7
20
0.55
0.27
10.8
40.5
24
21.9
0.33
13.6
40.9
23
39.5
0.41
16.3
39.5
22
22
0.52
20
0.61
0.74
26.1
35.3
19
19.6
0.20
8.4
40.9
23
22.4
0.27
10.8
39.5
22
38.1
0.37
14.1
38.1
21
36.7
0.45
16.7
36.7
20
21
0.57
20.2
35.3
19
38.0
39.4
40.8
40.4
36.6
38.0
39.4
40.8
40.4
8.1
8.2
8.2
8.3
8.0
8.1
8.2
8.2
8.3
15.9
18.5
21.7
24.9
27.8
10.7
13.5
16.2
19.6
22.3
26.0
8.3
10.7
14.1
16.6
20.1
23.4
8.5
11.3
14.6
17.5
20.5
24.3
8.7
11.7
14.8
18.3
0.39
0.45
0.55
0.65
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.45
0.57
0.69
0.22
0.31
0.41
0.52
0.63
0.79
0.25
0.34
0.46
0.59
COOLING
PE-10MYC-EU
PEH-10MYA-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
39.2
40.6
40.1
36.4
37.8
39.2
40.6
40.1
8.5
8.6
8.6
8.3
8.4
8.5
8.6
8.6
80
1,330
0.977
0.991
0.968
CMM
L/S
90
1,550
1.0
1.0
1.0
1,660
1.035
1.005
1.037
100
37.8
8.4
15.8
18.4
21.6
24.8
27.7
10.7
13.4
16.2
19.5
22.2
25.9
8.3
10.7
14.0
16.6
20.1
23.4
8.4
11.2
14.5
17.4
20.4
24.3
8.7
11.6
14.7
18.2
0.39
0.45
0.55
0.66
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.46
0.57
0.70
0.22
0.31
0.41
0.52
0.63
0.79
0.25
0.35
0.46
0.59
36.0
37.4
38.8
40.2
39.6
36.0
37.4
38.8
40.2
39.6
8.6
8.7
8.8
8.9
9.0
8.6
8.7
8.8
8.9
9.0
33.2
8.5
34.6
37.4
8.7
8.6
36.0
8.6
40.2
34.6
8.6
8.9
33.2
8.5
38.8
31.8
8.4
8.8
30.4
8.3
37.4
34.6
8.6
8.7
33.2
8.5
36.0
31.8
8.4
8.6
30.4
8.3
34.6
29.0
8.1
8.6
0.28
8.9
31.8
8.4
15.7
18.2
21.3
24.5
27.5
10.6
13.3
16.0
19.4
22.1
25.7
8.2
10.6
13.9
16.5
19.9
23.2
8.3
11.0
14.4
17.2
20.2
24.1
8.6
11.5
14.6
18.1
0.40
0.45
0.55
0.66
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.46
0.58
0.70
0.22
0.31
0.42
0.52
0.64
0.79
0.25
0.35
0.46
0.60
0.75
0.40
12.1
30.4
8.3
21.8
0.53
15.5
SHF
29.0
Q kW SHCkW
8.1
T/I kW
10.0
35.4
36.3
37.2
38.0
38.9
35.4
36.3
37.2
38.0
38.9
9.1
9.1
9.2
9.3
9.5
9.1
9.1
9.2
9.3
9.5
32.6
8.9
34.0
36.3
9.1
9.0
35.4
9.1
38.0
34.0
9.0
9.3
32.6
8.9
37.2
31.3
8.8
9.2
29.9
8.7
36.3
34.0
9.0
9.1
32.6
8.9
35.4
31.3
8.8
9.1
29.9
8.7
34.0
28.5
8.6
9.0
0.28
8.8
31.3
8.8
15.5
18.1
21.1
24.3
27.2
10.4
13.2
15.9
19.3
21.9
25.5
8.1
10.5
13.8
16.4
19.8
23.1
8.2
10.9
14.2
17.0
20.0
23.9
8.5
11.4
14.5
18.0
0.40
0.48
0.57
0.67
0.77
0.27
0.35
0.43
0.53
0.62
0.75
0.21
0.28
0.38
0.46
0.58
0.71
0.23
0.31
0.42
0.52
0.64
0.80
0.25
0.35
0.46
0.60
0.76
0.40
12.0
29.9
8.7
21.6
0.54
15.3
SHF
28.5
Q kW SHCkW
8.6
T/I kW
15.0
17.9
17.8
17
18
19
20
21
22
23
24
25
26
27
9.3
9.2
9.3
9.3
9.4
9.6
9.3
9.3
9.4
9.6
9.7
10.0
10.0
9.9
9.8
9.7
10.0
10.0
9.9
9.8
9.7
9.6
10.0
9.9
9.8
9.7
9.6
9.4
27.2
27.4
27.6
27.7
27.8
27.9
28.0
28.1
28.1
28.3
28.4
28.5
28.6
8.5
8.4
8.4
8.3
8.2
8.1
8.1
8.0
7.9
7.8
7.8
7.6
7.7
6.8
6.7
6.7
6.6
6.6
6.5
6.5
6.5
6.4
6.4
31.1
31.4
31.6
31.7
31.8
32.0
32.1
32.2
32.3
32.5
32.6
32.7
32.8
9.6
9.5
9.4
9.3
9.2
9.1
9.1
9.0
8.9
8.8
8.7
8.5
8.6
T/I kW
10.0
OUTDOOR WB ˚C
20.3
20.4
20.5
20.6
20.7
20.8
20.9
21.0
21.1
21.2
6.3
6.3
6.3
)
35.4
35.6
35.9
36.1
36.2
36.4
36.6
36.8
36.9
37.0
37.1
37.2
37.3
Q kW
HEATING
PEH-10MYA-EU
80
1,330
0.989
1.025
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
90
1,500
1.0
1.0
1,660
1.008
0.984
100
10.8
10.7
10.5
10.4
10.3
10.3
10.2
10.1
10.0
9.9
9.7
9.5
9.6
T/I kW
7.6
7.5
7.5
7.4
7.3
7.3
7.2
7.1
7.1
7.0
7.0
6.9
6.9
T/I kW
15.0
23.6
23.7
23.9
24.0
24.1
24.2
24.3
24.3
24.4
24.5
24.6
24.5
24.8
0.0
Factor for Various Air Flow
(
6.1
6.1
6.0
6.0
6.0
6.0
5.9
5.9
5.9
5.9
21.3
205.8
21.4
Q kW T/I kW Q kW
5.0
17.3
17.4
17.5
17.6
17.7
18.0
18.1
18.2
5.8
5.8
5.8
Q kW
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static
pressure: ESP = 62/125Pa”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
18.2
16
9.3
9.8
18.3
15
9.2
18.4
DB ˚C
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
T/I kW
INDOOR
PEH-10MYA-EU
(combined with PUH-10MYC2-EU)
Heating Capacity (Standard Air Flow)
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
36.4
8.3
33.6
8.2
35.0
37.8
8.4
8.2
36.4
8.3
40.6
35.0
8.2
8.6
33.6
8.2
39.2
32.2
8.1
8.5
30.8
8.0
37.8
35.0
8.2
8.4
33.6
8.2
36.4
32.2
8.1
8.3
30.8
8.0
35.0
29.4
7.8
8.2
0.28
9.0
32.2
8.1
0.74
0.39
12.2
30.8
8.0
21.9
0.53
15.6
29.4
SHF
Q kW SHCkW
5.0
OUTDOOR DB˚C
7.8
T/I kW
SHC:SENSIBLE HEAT CAPACITY
36.6
8.0
33.8
7.9
35.2
38.0
8.1
7.9
36.6
8.0
40.8
35.2
7.9
8.2
33.8
7.9
39.4
32.4
7.8
8.2
31.0
7.7
38.0
35.2
7.9
8.1
33.8
7.9
36.6
32.4
7.8
8.0
31.0
7.7
35.2
29.6
7.5
7.9
0.28
9.1
32.4
7.8
0.74
0.39
12.2
31.0
7.7
22.0
0.53
15.7
29.6
SHF
Q kW SHC kW
7.5
T/I kW
0.0
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
15
0.53
SHF
15.8
Q kW SHCkW
-5.0
29.7
DB˚C WB ˚C
INDOOR
PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYC2-EU)
Cooling Capacity (Standard Air Flow)
(Use for low ambient cooling parts)
- 28 9.1
0.70
23.6
33.6
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
80
1,330
0.977
0.991
0.968
CMM
L/S
Factor for Various Air Flow
PE-10MYC-EU
PEH-10MYA-EU
0.41
1,550
1.0
1.0
1.0
90
SHC:SENSIBLE HEAT CAPACITY
15.1
14.8
0.41
10.0
9.9
0.50
17.3
34.6
35.7
9.8
0.60
9.6
0.72
23.2
32.4
20.1
9.5
0.80
26.0
32.4
33.5
10.0
9.9
9.8
9.6
9.5
9.4
9.9
9.8
9.6
9.5
9.4
9.3
9.6
9.5
9.4
9.3
9.2
9.2
9.4
9.3
9.2
9.2
9.1
9.2
9.2
9.1
T/I kW
0.28
0.36
0.46
0.58
0.65
0.82
0.22
0.30
0.41
0.48
0.63
0.76
0.23
0.31
0.45
0.55
0.68
0.84
0.27
0.37
0.49
0.63
0.80
0.29
0.42
0.55
SHF
9.9
12.6
15.3
18.6
21.1
24.6
7.6
10.0
13.1
15.6
19.0
22.2
7.6
10.2
13.4
16.1
19.1
22.8
8.1
10.8
13.8
17.2
20.8
8.2
11.3
14.5
SHCkW
35.0
14.4
0.42
10.7
10.6
0.51
16.8
33.1
34.2
10.4
0.61
10.3
0.73
22.7
31.0
19.6
10.2
0.82
25.3
31.0
32.0
10.7
0.28
10.6
9.6
0.37
34.2
12.2
10.4
0.46
14.8
32.0
33.1
10.3
10.2
10.1
10.6
10.4
10.3
10.2
10.1
10.0
10.3
10.2
10.1
10.0
9.9
9.8
10.1
10.0
9.9
9.8
9.7
9.9
9.8
9.7
T/I kW
0.59
0.67
0.84
0.22
0.30
0.41
0.48
0.64
0.78
0.24
0.32
0.45
0.56
0.69
0.86
0.27
0.38
0.50
0.64
0.81
0.29
0.42
0.56
SHF
18.2
20.7
24.2
7.4
9.6
12.6
15.0
18.5
21.7
7.3
9.8
13.1
15.6
18.7
22.3
7.8
10.5
13.3
16.7
20.4
7.9
10.9
14.0
SHCkW
31.0
31.0
28.8
33.1
32.0
31.0
31.0
28.8
27.9
31.0
31.0
28.8
27.9
26.9
26.0
28.8
27.9
26.9
26.0
25.1
26.9
26.0
25.1
Q kW
OUTDOOR DB˚C
35.7
34.6
33.5
32.4
32.4
30.1
34.6
33.5
32.4
32.4
30.1
29.1
32.4
32.4
30.1
29.1
28.1
27.1
30.1
29.1
28.1
27.1
26.1
28.1
27.1
26.1
Q kW
30.0
100
1,660
1.035
1.005
1.037
40.0
14.0
0.43
11.5
11.4
0.52
16.4
31.4
32.5
11.2
0.63
11.1
0.76
22.3
29.4
19.1
11.0
0.85
25.1
29.4
30.4
11.5
0.29
9.3
11.4
32.5
0.38
11.2
0.48
14.5
30.4
11.8
11.1
0.61
17.8
29.4
31.4
11.0
10.9
11.4
11.2
11.1
11.0
10.9
10.8
11.1
11.0
10.9
10.8
10.7
10.6
10.9
10.8
10.7
10.6
10.5
10.7
10.6
10.5
T/I kW
0.69
0.86
0.22
0.31
0.42
0.50
0.66
0.80
0.24
0.32
0.46
0.58
0.71
0.88
0.27
0.38
0.51
0.66
0.83
0.30
0.43
0.57
SHF
20.2
23.6
7.1
9.3
12.3
14.7
18.0
21.2
7.0
9.5
12.6
15.3
18.2
21.8
7.5
10.1
13.0
16.3
19.9
7.6
10.5
13.6
SHCkW
29.4
27.3
31.4
30.4
29.4
29.4
27.3
26.5
29.4
29.4
27.3
26.5
25.6
24.7
27.3
26.5
25.6
24.7
23.9
25.6
24.7
23.9
Q kW
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
9.4
36.9
8.9
0.40
15.4
38.0
24
9.3
0.49
17.6
35.9
8.5
0.49
17.9
36.9
23
9.2
0.59
20.3
8.7
0.58
20.8
35.8
22
34.7
8.6
0.70
24.1
34.6
21
9.0
0.79
26.5
33.6
8.5
0.78
27.0
9.4
9.3
0.27
0.36
10.1
12.8
36.9
9.2
9.1
9.0
8.9
35.9
0.44
0.56
0.64
9.3
9.2
9.1
9.0
8.9
8.8
9.1
9.0
8.9
8.8
8.7
8.6
8.9
8.8
8.7
8.6
8.5
8.7
8.6
8.5
T/I kW
8.8
34.6
20
0.35
15.4
18.9
21.4
0.80
0.22
0.30
0.40
0.48
0.62
0.75
0.23
0.31
0.44
0.54
0.67
0.83
0.27
0.37
0.49
0.63
0.78
0.29
0.42
0.55
SHF
34.7
33.6
33.6
24.9
7.8
10.3
13.5
16.0
19.4
22.7
7.8
10.5
13.8
16.4
19.5
23.3
8.3
11.1
14.2
17.6
21.2
8.5
11.7
14.8
SHCkW
25.0
8.7
8.6
8.5
8.4
35.9
8.8
31.2
34.7
33.6
33.6
31.2
8.7
8.4
8.5
8.4
30.2
33.6
8.6
8.3
33.6
31.2
30.2
29.1
28.1
31.2
30.2
29.1
28.1
27.0
29.1
28.1
27.0
Q kW
8.5
8.4
8.3
8.3
8.2
8.4
8.3
8.3
8.2
8.1
8.3
8.2
8.1
T/I kW
8.9
38.0
24
13.0
0.44
0.55
0.63
0.79
0.22
0.29
0.40
0.47
0.61
0.74
0.23
0.31
0.44
0.54
0.66
0.82
0.26
0.36
0.48
0.62
0.77
0.29
0.41
0.54
SHF
0.27
36.9
23
15.7
19.1
21.7
25.3
8.0
10.4
13.7
16.2
19.7
23.0
8.1
10.8
14.1
16.8
19.9
23.7
8.4
11.3
14.4
17.8
21.5
8.7
11.9
15.1
SHCkW
10.3
35.8
34.6
20
22
32.1
19
34.6
36.9
23
21
35.8
22
32.1
19
34.6
31.1
18
21
34.6
21
34.6
34.6
20
20
32.1
30.0
17
19
28.9
16
31.1
32.1
19
18
31.1
28.9
16
18
27.8
15
30.0
30.0
17
17
28.9
27.8
15
16
Q kW
WB ˚C
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYE1-EU)
Cooling Capacity (Standard Air Flow)
12.0
12.1
12.2
11.7
11.8
12.0
12.1
12.3
12.4
11.8
12.0
12.1
12.3
12.4
0.31
0.23
0.89
0.71
0.62
0.49
0.38
0.29
0.89
0.78
0.65
0.53
0.44
9.0
6.7
22.8
19.5
17.1
14.0
11.3
8.8
24.5
21.6
18.5
15.7
13.4
29.5
25.7
27.6
27.6
28.6
29.5
30.5
27.6
27.6
28.6
29.5
30.5
12.0
20.6
24.9
28.6
11.8
0.24
6.7
27.6
11.8
11.7
0.33
9.1
27.6
0.43
11.6
0.48
12.2
25.7
11.9
11.5
0.59
14.8
24.9
27.6
11.4
0.73
17.6
24.1
11.7
11.7
0.91
21.2
23.3
0.52
11.6
0.28
7.1
25.7
14.2
11.5
0.39
9.7
24.9
27.6
11.4
0.52
12.5
24.1
11.6
11.3
0.67
15.7
23.3
0.68
11.5
0.85
19.2
22.5
17.5
11.4
0.30
7.2
24.1
25.7
11.3
0.43
10.0
23.3
0.83
T/I kW
SHF
0.58
13.1
22.5
46.0
SHCkW
Q kW
- 29 -
0.39
0.28
0.74
0.59
0.46
0.35
0.25
0.79
0.63
0.52
0.42
0.31
0.22
0.69
12.3
9.1
22.0
18.4
14.8
11.7
8.8
24.4
20.6
17.6
14.7
11.3
8.6
23.5
31.1
32.5
29.7
31.1
32.5
33.9
35.3
31.1
32.5
33.9
35.3
36.7
38.1
33.9
16
17
15
16
17
18
19
16
17
18
19
20
21
18
0.45
0.39
18.5
16.0
40.9
40.5
24
0.66
25.0
38.1
21
23
0.76
28.0
36.7
20
0.55
0.27
10.8
40.5
24
21.9
0.33
13.6
40.9
23
39.5
0.41
16.3
39.5
22
22
0.52
20
0.61
0.74
26.1
35.3
19
19.6
0.20
8.4
40.9
23
22.4
0.27
10.8
39.5
22
38.1
0.37
14.1
38.1
21
36.7
0.45
16.7
36.7
20
21
0.57
20.2
35.3
19
38.0
39.4
40.8
40.4
36.6
38.0
39.4
40.8
40.4
8.1
8.2
8.2
8.3
8.0
8.1
8.2
8.2
8.3
15.9
18.5
21.7
24.9
27.8
10.7
13.5
16.2
19.6
22.3
26.0
8.3
10.7
14.1
16.6
20.1
23.4
8.5
11.3
14.6
17.5
20.5
24.3
8.7
11.7
14.8
18.3
0.39
0.45
0.55
0.65
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.45
0.57
0.69
0.22
0.31
0.41
0.52
0.63
0.79
0.25
0.34
0.46
0.59
COOLING
PE-10MYC-EU
PEH-10MYA-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
39.2
40.6
40.1
36.4
37.8
39.2
40.6
40.1
8.5
8.6
8.6
8.3
8.4
8.5
8.6
8.6
80
1,330
0.977
0.991
0.968
CMM
L/S
90
1,550
1.0
1.0
1.0
1,660
1.035
1.005
1.037
100
37.8
8.4
15.8
18.4
21.6
24.8
27.7
10.7
13.4
16.2
19.5
22.2
25.9
8.3
10.7
14.0
16.6
20.1
23.4
8.4
11.2
14.5
17.4
20.4
24.3
8.7
11.6
14.7
18.2
0.39
0.45
0.55
0.66
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.46
0.57
0.70
0.22
0.31
0.41
0.52
0.63
0.79
0.25
0.35
0.46
0.59
36.0
37.4
38.8
40.2
39.6
36.0
37.4
38.8
40.2
39.6
8.6
8.7
8.8
8.9
9.0
8.6
8.7
8.8
8.9
9.0
33.2
8.5
34.6
37.4
8.7
8.6
36.0
8.6
40.2
34.6
8.6
8.9
33.2
8.5
38.8
31.8
8.4
8.8
30.4
8.3
37.4
34.6
8.6
8.7
33.2
8.5
36.0
31.8
8.4
8.6
30.4
8.3
34.6
29.0
8.1
8.6
0.28
8.9
31.8
8.4
15.7
18.2
21.3
24.5
27.5
10.6
13.3
16.0
19.4
22.1
25.7
8.2
10.6
13.9
16.5
19.9
23.2
8.3
11.0
14.4
17.2
20.2
24.1
8.6
11.5
14.6
18.1
0.40
0.45
0.55
0.66
0.76
0.27
0.33
0.41
0.52
0.61
0.74
0.20
0.27
0.37
0.46
0.58
0.70
0.22
0.31
0.42
0.52
0.64
0.79
0.25
0.35
0.46
0.60
0.75
0.40
12.1
30.4
8.3
21.8
0.53
15.5
SHF
29.0
Q kW SHCkW
8.1
T/I kW
10.0
35.4
36.3
37.2
38.0
38.9
35.4
36.3
37.2
38.0
38.9
9.1
9.1
9.2
9.3
9.5
9.1
9.1
9.2
9.3
9.5
32.6
8.9
34.0
36.3
9.1
9.0
35.4
9.1
38.0
34.0
9.0
9.3
32.6
8.9
37.2
31.3
8.8
9.2
29.9
8.7
36.3
34.0
9.0
9.1
32.6
8.9
35.4
31.3
8.8
9.1
29.9
8.7
34.0
28.5
8.6
9.0
0.28
8.8
31.3
8.8
15.5
18.1
21.1
24.3
27.2
10.4
13.2
15.9
19.3
21.9
25.5
8.1
10.5
13.8
16.4
19.8
23.1
8.2
10.9
14.2
17.0
20.0
23.9
8.5
11.4
14.5
18.0
0.40
0.48
0.57
0.67
0.77
0.27
0.35
0.43
0.53
0.62
0.75
0.21
0.28
0.38
0.46
0.58
0.71
0.23
0.31
0.42
0.52
0.64
0.80
0.25
0.35
0.46
0.60
0.76
0.40
12.0
29.9
8.7
21.6
0.54
15.3
SHF
28.5
Q kW SHCkW
8.6
T/I kW
15.0
17.9
17.8
17
18
19
20
21
22
23
24
25
26
27
9.3
9.2
9.3
9.3
9.4
9.6
9.3
9.3
9.4
9.6
9.7
10.0
10.0
9.9
9.8
9.7
10.0
10.0
9.9
9.8
9.7
9.6
10.0
9.9
9.8
9.7
9.6
9.4
27.2
27.4
27.6
27.7
27.8
27.9
28.0
28.1
28.1
28.3
28.4
28.5
28.6
8.5
8.4
8.4
8.3
8.2
8.1
8.1
8.0
7.9
7.8
7.8
7.6
7.7
6.8
6.7
6.7
6.6
6.6
6.5
6.5
6.5
6.4
6.4
31.1
31.4
31.6
31.7
31.8
32.0
32.1
32.2
32.3
32.5
32.6
32.7
32.8
9.6
9.5
9.4
9.3
9.2
9.1
9.1
9.0
8.9
8.8
8.7
8.5
8.6
T/I kW
10.0
OUTDOOR WB ˚C
20.3
20.4
20.5
20.6
20.7
20.8
20.9
21.0
21.1
21.2
6.3
6.3
6.3
)
35.4
35.6
35.9
36.1
36.2
36.4
36.6
36.8
36.9
37.0
37.1
37.2
37.3
Q kW
HEATING
PEH-10MYA-EU
80
1,330
0.989
1.025
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
90
1,500
1.0
1.0
1,660
1.008
0.984
100
10.8
10.7
10.5
10.4
10.3
10.3
10.2
10.1
10.0
9.9
9.7
9.5
9.6
T/I kW
7.6
7.5
7.5
7.4
7.3
7.3
7.2
7.1
7.1
7.0
7.0
6.9
6.9
T/I kW
15.0
23.6
23.7
23.9
24.0
24.1
24.2
24.3
24.3
24.4
24.5
24.6
24.5
24.8
0.0
Factor for Various Air Flow
(
6.1
6.1
6.0
6.0
6.0
6.0
5.9
5.9
5.9
5.9
21.3
205.8
21.4
Q kW T/I kW Q kW
5.0
17.3
17.4
17.5
17.6
17.7
18.0
18.1
18.2
5.8
5.8
5.8
Q kW
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static
pressure: ESP = 62/125Pa”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
18.2
16
9.3
9.8
18.3
15
9.2
18.4
DB ˚C
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
T/I kW
INDOOR
PEH-10MYA-EU
(combined with PUH-10MYE1-EU)
Heating Capacity (Standard Air Flow)
T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.)
36.4
8.3
33.6
8.2
35.0
37.8
8.4
8.2
36.4
8.3
40.6
35.0
8.2
8.6
33.6
8.2
39.2
32.2
8.1
8.5
30.8
8.0
37.8
35.0
8.2
8.4
33.6
8.2
36.4
32.2
8.1
8.3
30.8
8.0
35.0
29.4
7.8
8.2
0.28
9.0
32.2
8.1
0.74
0.39
12.2
30.8
8.0
21.9
0.53
15.6
29.4
SHF
Q kW SHCkW
5.0
OUTDOOR DB˚C
7.8
T/I kW
SHC:SENSIBLE HEAT CAPACITY
36.6
8.0
33.8
7.9
35.2
38.0
8.1
7.9
36.6
8.0
40.8
35.2
7.9
8.2
33.8
7.9
39.4
32.4
7.8
8.2
31.0
7.7
38.0
35.2
7.9
8.1
33.8
7.9
36.6
32.4
7.8
8.0
31.0
7.7
35.2
29.6
7.5
7.9
0.28
9.1
32.4
7.8
0.74
0.39
12.2
31.0
7.7
22.0
0.53
15.7
29.6
SHF
Q kW SHC kW
7.5
T/I kW
0.0
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
15
0.53
SHF
15.8
Q kW SHCkW
-5.0
29.7
DB˚C WB ˚C
INDOOR
PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYE1-EU)
Cooling Capacity (Standard Air Flow)
(Use for low ambient cooling parts)
- 30 -
25.1
19.5
14.3
39.7
33.5
28.8
23.7
18.4
14.0
38.0
47.0
48.5
50.2
52.1
47.0
48.5
50.2
52.1
53.8
55.8
50.2
16
17
18
19
16
17
18
19
20
21
18
32.8
27.5
23.5
17.9
14.1
42.3
36.3
31.8
26.8
22.4
18.0
45.7
40.8
35.4
30.6
26.8
53.8
55.8
57.7
59.6
52.1
53.8
55.8
57.7
59.6
61.5
53.8
55.8
57.7
59.6
61.5
20
21
22
23
19
20
21
22
23
24
20
21
22
23
24
35.8
52.1
19
30.3
45.5
15
15.2
48.5
17
20.4
26.1
47.0
45.5
15
SHCkW
16
Q kW
WB ˚C
20.0
16.3
15.8
15.6
15.4
15.1
16.3
15.8
15.6
15.4
15.1
14.7
15.8
15.6
15.4
15.1
14.7
14.5
15.4
15.1
14.7
14.5
14.2
14.0
14.7
14.5
14.2
14.0
13.8
14.2
14.0
13.8
T/I kW
59.8
57.9
56.0
54.1
52.1
59.8
57.9
56.0
54.1
52.1
50.4
57.9
56.0
54.1
52.1
50.4
48.7
54.1
52.1
50.4
48.7
47.0
45.5
50.4
48.7
47.0
45.5
44.0
47.0
45.5
44.0
Q kW
26.5
30.0
34.6
40.0
45.0
17.7
22.0
26.2
31.0
35.4
41.3
13.8
17.5
23.1
27.0
32.1
37.1
13.5
17.8
23.0
28.2
32.7
38.9
13.8
19.2
24.9
29.9
35.0
14.8
20.0
25.7
SHCkW
25.0
0.44
0.52
0.62
0.74
0.86
0.30
0.38
0.47
0.57
0.68
0.82
0.24
0.31
0.43
0.52
0.64
0.76
0.25
0.34
0.46
0.58
0.70
0.85
0.27
0.39
0.53
0.66
0.79
0.32
0.44
0.58
SHF
AIR VOLUME
CAPACITY
TOTAL INPUT
SHC
PE-15MYC1-EU
COOLING
120
2,000
0.976
0.991
0.963
CMM
L/S
2,334
1.0
1.0
1.0
140
SHC:SENSIBLE HEAT CAPACITY
0.44
0.51
0.61
0.73
0.85
0.29
0.38
0.46
0.57
0.67
0.81
0.24
0.31
0.42
0.51
0.63
0.76
0.25
0.34
0.46
0.57
0.69
0.85
0.27
0.39
0.52
0.65
0.79
0.31
0.43
0.57
SHF
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PE-15MYC1-EU
57.9
56.2
54.3
52.3
50.6
57.9
56.2
54.3
52.3
50.6
48.9
56.2
54.3
52.3
50.6
48.9
47.2
52.3
50.6
48.9
47.2
45.5
44.0
48.9
47.2
45.5
44.0
42.5
45.5
44.0
42.5
Q kW
(
26.6
29.9
34.2
39.4
44.5
17.2
21.5
25.7
30.4
34.8
40.6
13.5
17.2
22.6
26.6
31.6
36.7
13.1
17.5
22.6
27.7
32.1
38.3
13.5
18.7
24.3
29.3
34.5
14.2
19.4
25.1
SHCkW
30.0
0.46
0.53
0.63
0.75
0.88
0.30
0.38
0.47
0.58
0.69
0.83
0.24
0.32
0.43
0.53
0.65
0.78
0.25
0.35
0.46
0.59
0.71
0.87
0.28
0.40
0.54
0.67
0.81
0.31
0.44
0.59
SHF
17.9
17.6
17.2
17.0
16.7
17.9
17.6
17.2
17.0
16.7
16.5
17.6
17.2
17.0
16.7
16.5
16.3
17.0
16.7
16.5
16.3
15.8
15.6
16.5
16.3
15.8
15.6
15.4
15.8
15.6
15.4
T/I kW
55.5
54.1
52.1
50.6
48.7
55.5
54.1
52.1
50.6
48.7
47.0
54.1
52.1
50.6
48.7
47.0
45.5
50.6
48.7
47.0
45.5
44.0
42.5
47.0
45.5
44.0
42.5
41.0
44.0
42.5
41.0
Q kW
OUTDOOR DB˚C
35.0
26.3
29.5
33.5
38.8
43.5
16.6
20.9
25.0
29.9
34.0
39.4
13.1
16.6
22.1
26.0
30.9
36.0
12.7
16.9
22.0
27.1
31.6
37.5
13.1
18.2
23.7
28.7
34.1
13.7
18.9
24.5
SHCkW
0.47
0.55
0.64
0.77
0.89
0.30
0.39
0.48
0.59
0.70
0.84
0.24
0.32
0.44
0.53
0.66
0.79
0.25
0.35
0.47
0.59
0.72
0.88
0.28
0.40
0.54
0.68
0.83
0.31
0.44
0.60
SHF
19.0
18.8
18.3
18.1
17.9
19.0
18.8
18.3
18.1
17.9
17.6
18.8
18.3
18.1
17.9
17.6
17.2
18.1
17.9
17.6
17.2
17.0
16.7
17.6
17.2
17.0
16.7
16.5
17.0
16.7
16.5
T/I kW
53.8
51.9
50.4
48.7
47.0
53.8
51.9
50.4
48.7
47.0
45.5
51.9
50.4
48.7
47.0
45.5
44.0
48.7
47.0
45.5
44.0
42.3
40.8
45.5
44.0
42.3
40.8
39.1
42.3
40.8
39.1
Q kW
40.0
26.4
29.2
33.3
38.1
42.7
16.2
20.4
24.8
29.7
34.0
39.5
12.5
16.2
21.6
25.6
30.5
35.4
12.4
16.7
21.7
26.7
31.0
36.8
12.9
17.9
23.2
28.1
32.9
13.5
18.4
23.8
SHCkW
)
0.49
0.56
0.66
0.78
0.91
0.30
0.39
0.49
0.61
0.72
0.87
0.24
0.32
0.44
0.55
0.67
0.80
0.26
0.35
0.48
0.61
0.73
0.90
0.28
0.41
0.55
0.69
0.84
0.32
0.45
0.61
SHF
2,660
1.025
1.009
1.044
160
T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “0.2kw” from “T/I value of this table”.
17.0
16.7
16.3
16.0
15.8
17.0
16.7
16.3
16.0
15.8
15.6
16.7
16.3
16.0
15.8
15.6
15.1
16.0
15.8
15.6
15.1
14.9
14.7
15.6
15.1
14.9
14.7
14.5
14.9
14.7
14.5
T/I kW
Cooling Capacity (Standard Air Flow)
20.1
19.9
19.7
19.4
19.2
20.1
19.9
19.7
19.4
19.2
18.8
19.9
19.7
19.4
19.2
18.8
18.5
19.4
19.2
18.8
18.5
18.3
17.9
18.8
18.5
18.3
17.9
17.6
18.3
17.9
17.6
T/I kW
51.1
49.4
47.9
46.4
44.7
51.1
49.4
47.9
46.4
44.7
43.2
49.4
47.9
46.4
44.7
43.2
41.7
46.4
44.7
43.2
41.7
40.4
39.1
43.2
41.7
40.4
39.1
37.6
40.4
39.1
37.6
Q kW
46.0
25.7
28.6
32.4
37.0
41.2
15.4
19.7
24.2
29.3
33.4
38.8
11.9
15.5
20.9
24.9
29.5
34.1
12.0
16.1
21.0
25.8
30.2
36.1
12.5
17.4
22.6
27.3
32.0
13.2
18.0
23.1
SHCkW
SHF
0.50
0.58
0.68
0.80
0.92
0.30
0.40
0.50
0.63
0.75
0.90
0.24
0.32
0.45
0.56
0.68
0.82
0.26
0.36
0.49
0.62
0.75
0.92
0.29
0.42
0.56
0.70
0.85
0.33
0.46
0.62
21.7
21.5
21.0
20.8
20.6
21.7
21.5
21.0
20.8
20.6
20.1
21.5
21.0
20.8
20.6
20.1
19.9
20.8
20.6
20.1
19.9
19.7
19.4
20.1
19.9
19.7
19.4
19.2
19.7
19.4
19.2
T/I kW
- 31 -
52.2
47.0
21
18
55.8
57.6
24
52.2
21
23
50.4
20
54.0
57.6
24
22
55.8
50.4
20
23
48.8
19
54.0
55.8
23
22
54.0
22
52.2
52.2
21
21
50.4
20
48.8
50.4
20
19
48.8
45.4
17
19
44.0
16
47.0
48.8
19
18
47.0
44.0
16
18
42.6
15
45.4
45.4
17
17
44.0
42.6
15
16
Q kW
WB ˚C
15.6
0.44
25.1
16.1
16.3
0.52
0.44
28.1
24.9
54.2
56.0
COOLING
PEH-15MYA-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
120
2,000
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
140
2,334
1.0
1.0
1.0
16.9
17.1
0.53
0.46
28.0
24.9
52.6
54.2
160
2,660
1.025
1.009
1.044
35.0
17.6
18.0
18.2
0.64
0.55
0.47
31.4
27.6
24.6
50.6
52.0
17.4
0.77
36.3
47.4
48.8
17.1
0.89
18.2
18.0
17.6
17.4
17.1
16.9
18.0
17.6
17.4
17.1
16.9
16.5
17.4
17.1
16.9
16.5
16.3
16.1
16.9
16.5
16.3
16.1
15.8
16.3
16.1
15.8
T/I kW
0.30
0.39
0.48
0.59
0.70
0.84
0.24
0.32
0.44
0.53
0.66
0.79
0.25
0.35
0.47
0.59
0.72
0.88
0.28
0.40
0.54
0.68
0.83
0.31
0.44
0.60
SHF
40.8
15.5
19.5
23.4
28.0
31.8
36.9
12.2
15.6
20.7
24.3
28.9
33.7
11.9
15.9
20.6
25.3
29.6
35.1
12.3
17.1
22.2
26.9
32.0
12.8
17.7
23.0
SHCkW
45.6
52.0
50.6
48.8
47.4
45.6
44.0
50.6
48.8
47.4
45.6
44.0
42.6
47.4
45.6
44.0
42.6
41.2
39.8
44.0
42.6
41.2
39.8
38.4
41.2
39.8
38.4
Q kW
40.0
18.9
19.1
19.3
0.66
0.56
0.49
27.3
24.7
48.6
50.4
18.7
0.78
35.7
45.6
31.2
18.4
0.91
40.0
44.0
47.2
19.3
0.30
19.1
18.9
18.7
18.4
18.0
19.1
18.9
18.7
18.4
18.0
17.8
18.7
18.4
18.0
17.8
17.6
17.1
18.0
17.8
17.6
17.1
16.9
17.6
17.1
16.9
T/I kW
0.39
0.49
0.61
0.72
0.87
0.24
0.32
0.44
0.55
0.67
0.80
0.26
0.35
0.48
0.61
0.73
0.90
0.28
0.41
0.55
0.69
0.84
0.32
0.45
0.61
SHF
15.1
19.1
23.2
27.9
31.8
37.0
11.7
15.2
20.2
24.0
28.6
33.1
11.6
15.6
20.3
25.0
29.0
34.4
12.1
16.8
21.7
26.3
30.8
12.6
17.2
22.2
SHCkW
50.4
48.6
47.2
45.6
44.0
42.6
48.6
47.2
45.6
44.0
42.6
41.2
45.6
44.0
42.6
41.2
39.6
38.2
42.6
41.2
39.6
38.2
36.6
39.6
38.2
36.6
Q kW
case of “indoor fan external static pressure: ESP = 200Pa”.
( InIf you
need “ESP = 100Pa”, please subtract “0.8kw” from “T/I value of this table”. )
16.5
16.3
0.75
0.63
16.1
17.1
16.9
16.5
16.3
16.1
15.8
16.9
16.5
16.3
16.1
15.8
15.6
16.3
16.1
15.8
15.6
15.2
15.0
15.8
15.6
15.2
15.0
14.8
15.2
15.0
14.8
T/I kW
0.88
0.30
0.38
0.47
0.58
0.69
0.83
0.24
0.32
0.43
0.53
0.65
0.78
0.25
0.35
0.46
0.59
0.71
0.87
0.28
0.40
0.54
0.67
0.81
0.31
0.44
0.59
SHF
OUTDOOR DB˚C
32.0
36.9
41.6
16.1
20.1
24.1
28.5
32.6
38.0
12.6
16.1
21.1
25.0
29.6
34.4
12.3
16.4
21.2
25.9
30.1
35.8
12.6
17.5
22.8
27.4
32.4
13.3
18.2
23.5
SHCkW
30.0
50.8
49.0
47.4
54.2
52.6
50.8
49.0
47.4
45.8
52.6
50.8
49.0
47.4
45.8
44.2
49.0
47.4
45.8
44.2
42.6
41.2
45.8
44.2
42.6
41.2
39.8
42.6
41.2
39.8
Q kW
T/I:TOTAL INPUT
15.6
15.4
15.2
16.3
16.1
15.6
15.4
15.2
15.0
16.1
15.6
15.4
15.2
15.0
14.5
15.4
15.2
15.0
14.5
14.3
14.1
15.0
14.5
14.3
14.1
13.9
14.3
14.1
13.9
T/I kW
0.62
0.74
0.86
0.30
0.38
0.47
0.57
0.68
0.82
0.24
0.31
0.43
0.52
0.64
0.76
0.25
0.34
0.46
0.58
0.70
0.85
0.27
0.39
0.53
0.66
0.79
0.32
0.44
0.58
SHF
32.4
37.4
42.1
16.6
20.6
24.5
29.0
33.2
38.7
12.9
16.4
21.6
25.3
30.1
34.8
12.6
16.7
21.6
26.4
30.6
36.4
12.9
17.9
23.4
28.0
32.7
13.9
18.8
24.0
SHCkW
52.4
50.6
48.8
56.0
54.2
52.4
50.6
48.8
47.2
54.2
52.4
50.6
48.8
47.2
45.6
50.6
48.8
47.2
45.6
44.0
42.6
47.2
45.6
44.0
42.6
41.2
44.0
42.6
41.2
Q kW
25.0
SHC:SENSIBLE HEAT CAPACITY
15.2
0.51
28.6
14.8
14.5
15.6
15.2
15.0
14.8
14.5
14.1
15.2
15.0
14.8
14.5
14.1
13.9
14.8
14.5
14.1
13.9
13.7
13.5
14.1
13.9
13.7
13.5
13.2
13.7
13.5
13.2
T/I kW
15.0
0.73
0.85
0.29
0.38
0.46
0.57
0.67
0.81
0.24
0.31
0.42
0.51
0.63
0.76
0.25
0.34
0.46
0.57
0.69
0.85
0.27
0.39
0.52
0.65
0.79
0.31
0.43
0.57
SHF
0.61
33.2
38.1
42.8
16.9
21.0
25.1
29.8
34.0
39.6
13.2
16.8
21.9
25.8
30.8
35.6
13.1
17.2
22.2
27.0
31.3
37.2
13.4
18.3
23.5
28.4
33.5
14.2
19.1
24.5
SHCkW
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PEH-15MYA-EU
Cooling Capacity (Standard Air Flow)
20.2
20.6
20.8
0.50
24.1
47.8
19.7
34.7
43.4
0.58
20.8
0.92
38.6
41.8
26.7
20.6
0.30
14.4
47.8
46.2
20.2
0.40
18.5
46.2
20.0
20.0
0.50
22.6
44.8
0.68
19.7
0.63
27.4
43.4
30.3
19.3
0.75
31.2
41.8
44.8
20.6
0.90
36.3
40.4
0.80
20.2
0.24
11.1
46.2
19.1
20.0
20.0
0.82
31.9
39.0
0.32
19.7
0.26
11.3
43.4
14.5
19.3
0.36
15.0
41.8
44.8
19.1
0.49
19.6
40.4
19.7
18.9
0.62
24.1
39.0
0.45
18.7
0.75
28.2
37.8
19.6
19.3
0.92
33.8
36.6
43.4
19.1
0.29
11.7
40.4
19.3
18.9
0.42
16.3
39.0
0.56
18.7
0.56
21.2
37.8
23.3
18.4
0.70
25.6
36.6
41.8
18.9
0.85
30.0
35.2
0.68
18.7
0.33
12.3
37.8
27.6
18.4
0.46
16.8
36.6
40.4
T/I kW
SHF
0.62
21.7
35.2
46.0
SHCkW
Q kW
- 32 -
54.8
49.4
21
18
0.24
0.81
0.67
0.57
0.46
0.37
0.28
0.83
0.72
13.8
41.4
35.6
31.3
26.1
21.8
17.5
44.2
39.6
56.6
58.4
51.2
53.0
54.8
56.6
58.4
62.6
53.0
54.8
23
19
20
21
22
23
24
20
21
0.61
0.51
0.41
34.7
29.6
25.6
56.6
58.4
62.6
23
24
0.31
22
17.5
0.41
22
22.7
54.8
0.50
21
26.7
0.63
0.76
0.26
0.35
0.46
0.57
0.69
0.85
0.28
0.38
0.50
0.64
0.80
0.31
0.43
0.57
53.0
32.2
37.3
14.1
18.4
23.5
28.1
32.7
38.8
14.4
19.0
23.8
29.3
35.0
14.9
19.8
25.3
SHF
20
51.2
53.0
19
51.2
20
47.6
17
19
45.8
16
49.4
51.2
19
18
49.4
45.8
16
18
44.0
15
47.6
47.6
17
17
45.8
16
44.0
Q kW SHCkW
-5.0
AIR VOLUME
CAPACITY
TOTAL INPUT
SHC
PEH-15MYA-EU
COOLING
120
2,000
0.976
0.991
0.963
CMM
L/S
2,334
1.0
1.0
1.0
140
2,660
1.025
1.009
1.044
160
T/I:TOTAL INPUT
0.42
25.4
0.72
39.3
54.4
14.7
61.2
0.83
43.9
52.6
14.5
15.7
0.28
17.4
61.2
15.7
0.51
0.37
21.6
57.9
15.2
29.3
0.46
25.9
56.1
14.9
57.9
0.57
30.9
54.4
14.7
15.2
0.67
35.2
52.6
14.5
0.61
0.80
40.9
50.8
14.2
34.4
0.24
13.6
57.9
15.2
56.1
0.31
17.3
56.1
14.9
14.9
0.41
0.50
0.63
0.75
0.25
0.34
0.46
0.57
0.68
0.84
0.28
0.38
0.50
0.64
0.79
0.31
0.43
0.57
22.5
26.5
31.8
36.9
13.8
18.1
23.2
27.9
32.4
38.4
14.1
18.8
23.8
29.1
34.7
14.8
19.6
25.1
SHF
54.4
52.6
50.8
49.1
54.4
52.6
50.8
49.1
47.3
45.6
50.8
49.1
47.3
45.6
43.8
47.3
45.6
43.8
Q kW SHCkW
5.0
(
51.6
53.5
55.3
57.2
59.0
51.6
53.5
15.3
15.6
15.8
16.1
16.6
15.3
15.6
59.0
49.9
15.1
16.6
57.2
16.1
57.2
55.3
15.8
16.1
53.5
15.6
55.3
51.6
15.3
15.8
49.9
48.2
53.5
51.6
49.9
48.2
46.6
44.9
49.9
48.2
46.6
44.9
43.2
46.6
44.9
43.2
25.2
28.8
33.6
38.5
43.2
17.0
21.2
25.3
30.2
34.4
40.0
13.4
17.0
22.1
26.0
31.1
36.0
13.3
17.5
22.6
27.3
31.7
37.6
13.6
18.4
23.6
28.6
33.9
14.4
19.3
24.7
Q kW SHCkW
15.1
14.6
15.6
15.3
15.1
14.6
14.3
14.1
15.1
14.6
14.3
14.1
13.9
14.3
14.1
13.9
T/I kW
0.43
0.50
0.61
0.72
0.84
0.29
0.37
0.46
0.56
0.67
0.80
0.23
0.31
0.41
0.50
0.62
0.75
0.25
0.34
0.45
0.57
0.68
0.84
0.27
0.38
0.51
0.64
0.78
0.31
0.43
0.57
SHF
15.0
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.4
28.5
28.5
28.5
28.3
28.1
28.1
28.1
27.7
27.7
26
27
15.0
14.5
14.3
14.1
13.9
15.0
14.5
14.3
14.1
13.9
13.9
14.5
14.3
14.1
14.9
14.9
14.7
14.7
14.5
14.3
14.3
14.0
14.0
13.8
13.8
13.6
13.6
47.5
47.7
48.1
48.1
48.3
48.5
48.5
48.7
48.7
48.9
49.1
49.3
49.3
16.5
16.5
16.3
16.1
16.1
15.8
15.6
15.4
15.4
15.2
15.2
15.6
14.7
T/I kW
10.0
HEATING
PEH-15MYA-EU
13.6
13.4
13.4
13.4
13.2
13.2
12.9
12.9
12.7
12.7
12.7
12.5
12.5
T/I kW
53.7
53.9
54.3
54.3
54.5
54.7
54.7
54.9
54.9
55.3
55.3
55.5
55.7
Q kW
18.3
18.1
18.1
17.8
17.6
17.4
17.4
17.2
16.9
16.7
16.5
16.3
16.1
T/I kW
15.0
36.5
36.7
37.3
37.1
37.3
37.5
37.5
37.7
37.7
37.9
38.1
38.1
38.3
0.0
140
2,334
1.0
1.0
120
2,000
0.989
1.015
CMM
L/S
CAPACITY
TOTAL INPUT
AIR VOLUME
Factor for Various Air Flow
(
41.7
42.1
42.5
42.5
42.5
42.7
42.9
42.9
42.9
43.3
43.3
43.5
43.5
12.3
12.3
12.3
12.3
12.0
12.0
12.0
11.8
11.8
11.8
11.6
OUTDOOR WB ˚C
31.9
32.1
32.5
32.3
32.5
32.7
32.7
32.9
32.9
33.1
33.3
11.6
11.6
Q kW
1.011
0.989
2,660
160
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “0.8kw” from “T/I
value of this table”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
13.9
25
24
23
22
21
20
19
INDOOR
)
10.9
28.9
18
17
33.5
33.5
Q kW T/I kW Q kW
10.9
29.1
5.0
10.7
29.3
16
10.7
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
29.5
15
DB ˚C
INDOOR
PEH-15MYA-EU
Heating Capacity
(Standard Air Flow)
13.9
13.2
14.1
13.9
13.9
13.2
13.0
120.8
13.9
13.2
13.0
12.8
12.6
13.0
12.8
12.6
T/I kW
In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “0.8kw” from “T/I value
of this table”.
0.42
0.72
38.9
53.9
16.1
25.3
0.83
43.5
52.2
15.9
60.2
0.29
17.2
60.2
16.9
16.9
0.37
21.4
57.4
16.7
0.51
0.46
25.6
55.6
16.4
29.1
0.57
30.5
53.9
16.1
57.4
0.67
34.8
52.2
15.9
16.7
0.80
40.5
50.5
15.4
0.61
0.24
13.5
57.4
16.7
34.0
0.31
17.1
55.6
16.4
55.6
0.41
22.3
53.9
16.1
16.4
0.50
0.62
0.75
0.25
0.34
0.45
0.57
0.68
0.84
0.27
0.38
0.50
0.64
0.79
0.31
0.43
0.57
26.2
31.5
36.5
13.6
17.8
22.9
27.6
32.0
38.0
13.9
18.6
23.7
28.9
34.3
14.6
19.5
24.9
SHF
52.2
50.5
48.8
53.9
52.2
50.5
48.8
47.0
45.3
50.5
48.8
47.0
45.3
43.6
47.0
45.3
43.6
Q kW SHCkW
10.0
15.9
15.4
15.1
16.1
15.9
15.4
15.1
14.8
14.6
15.4
15.1
14.8
14.6
14.3
14.8
14.6
14.3
T/I kW
OUTDOOR DB˚C
14.7
14.5
14.2
13.7
14.7
14.5
14.2
13.7
13.7
13.5
14.2
13.7
13.7
13.5
13.2
13.7
13.5
13.2
T/I kW
SHC:SENSIBLE HEAT CAPACITY
0.41
25.5
62.0
0.72
39.4
54.6
13.5
14.4
0.83
44.0
52.8
13.3
0.51
0.28
17.4
62.0
14.4
29.5
0.37
21.7
58.1
14.2
58.1
0.46
26.0
56.3
13.7
14.2
0.57
31.1
54.6
13.5
0.61
0.67
35.4
52.8
13.3
34.5
0.81
41.1
51.0
13.1
56.3
0.24
13.7
58.1
14.2
13.7
0.31
0.41
0.50
0.63
0.75
0.26
0.35
0.46
0.57
0.69
0.84
0.28
0.38
0.50
0.64
0.79
0.31
0.43
0.57
17.4
22.6
26.6
32.0
37.1
14.0
18.2
23.4
28.0
32.6
38.6
14.2
18.9
23.8
29.2
34.8
14.8
19.7
25.2
SHF
56.3
54.6
52.8
51.0
49.3
54.6
52.8
51.0
49.3
47.5
45.8
51.0
49.3
47.5
45.8
44.0
47.5
45.8
44.0
Q kW SHC kW
13.7
13.5
13.3
13.1
12.8
13.5
13.3
13.1
12.8
12.6
12.4
13.1
12.8
12.6
12.4
12.2
12.6
12.4
12.2
T/I kW
0.0
Factor for Various Air Flow
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
15
DB˚C WB˚C
INDOOR
PEH-15MYA-EU
(Use for low ambient cooling parts)
Cooling Capacity (Standard Air Flow)
)
- 33 -
73.8
71.8
69.4
67.2
67.2
73.8
71.8
69.4
67.2
67.2
62.4
71.8
69.4
67.2
67.2
62.4
60.4
67.2
67.2
62.4
60.4
58.2
56.2
62.4
60.4
58.2
56.2
54.0
58.2
56.2
54.0
Q kW
COOLING
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
160
2,660
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
PE-20MYC-EU
30.4
35.4
41.4
47.9
53.5
20.5
26.4
31.3
38.3
43.2
50.1
16.2
20.8
27.4
32.5
39.3
45.3
15.9
21.2
27.9
33.6
39.0
47.1
17.1
22.8
28.9
35.7
42.3
17.6
23.6
30.1
SHCkW
25.0
0.41
0.49
0.60
0.71
0.80
0.28
0.37
0.45
0.57
0.64
0.80
0.23
0.30
0.41
0.48
0.63
0.75
0.24
0.32
0.45
0.56
0.67
0.84
0.27
0.38
0.50
0.63
0.78
0.30
0.42
0.56
SHF
3,000
1.0
1.0
1.0
180
SHC:SENSIBLE HEAT CAPACITY
19.4
0.41
31.1
76.0
24
18.7
0.71
48.8
69.2
21
19.2
18.5
0.79
54.5
69.2
20
0.49
19.4
0.28
21.0
76.0
24
36.2
19.2
0.36
26.8
73.8
23
73.8
19.0
0.45
31.9
71.6
22
23
18.7
0.56
38.8
69.2
21
19.0
18.5
0.63
43.9
69.2
20
0.59
18.3
0.79
50.9
64.2
19
42.3
19.2
0.22
16.6
73.8
23
71.6
19.0
0.30
21.2
71.6
22
22
18.7
0.40
27.9
69.2
21
18.3
0.62
18.1
39.8
0.74
18.7
18.5
64.2
19
46.0
0.24
18.5
0.48
62.2
18
16.5
0.32
18.3
18.1
18.1
17.9
18.3
18.1
18.1
17.9
17.7
18.1
17.9
17.7
T/I kW
33.0
69.2
21
21.9
0.44
0.55
0.67
0.83
0.27
0.37
0.49
0.63
0.77
0.30
0.42
0.55
SHF
69.2
69.2
20
28.5
34.3
39.9
47.8
17.4
23.2
29.3
36.2
43.1
18.0
24.1
30.8
SHCkW
20
64.2
60.0
17
19
57.8
16
62.2
64.2
19
18
62.2
57.8
16
18
55.6
15
60.0
60.0
17
17
57.8
55.6
15
16
Q kW
WB ˚C
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PE-20MYC-EU
71.4
69.2
67.0
64.8
64.8
71.4
69.2
67.0
64.8
64.8
60.2
69.2
67.0
64.8
64.8
60.2
58.2
64.8
64.8
60.2
58.2
56.2
54.2
60.2
58.2
56.2
54.2
52.2
56.2
54.2
52.2
Q kW
3,320
1.025
1.009
1.044
200
T/I:TOTAL INPUT
20.5
20.3
20.1
19.8
19.6
20.5
20.3
20.1
19.8
19.6
19.4
20.3
20.1
19.8
19.6
19.4
19.2
19.8
19.6
19.4
19.2
19.0
18.7
19.4
19.2
19.0
18.7
18.5
19.0
18.7
18.5
T/I kW
Cooling Capacity (Standard Air Flow)
(
0.42
0.50
0.61
0.73
0.81
0.28
0.37
0.46
0.58
0.66
0.82
0.23
0.30
0.41
0.49
0.64
0.76
0.24
0.32
0.45
0.56
0.68
0.85
0.28
0.38
0.50
0.64
0.80
0.30
0.42
0.56
SHF
21.8
21.6
21.4
20.9
20.7
21.8
21.6
21.4
20.9
20.7
20.5
21.6
21.4
20.9
20.7
20.5
20.3
20.9
20.7
20.5
20.3
20.1
20.1
20.5
20.3
20.1
20.1
19.8
20.1
20.1
19.8
T/I kW
68.4
66.2
64.0
62.0
62.0
68.4
66.2
64.0
62.0
62.0
57.6
66.2
64.0
62.0
62.0
57.6
55.8
62.0
62.0
57.6
55.8
53.8
52.0
57.6
55.8
53.8
52.0
50.2
53.8
52.0
50.2
Q kW
OUTDOOR DB˚C
35.0
29.3
34.0
39.8
46.0
51.2
19.6
25.2
30.1
36.9
41.8
48.6
15.3
19.6
25.8
30.5
37.4
43.5
14.9
20.0
26.3
31.9
37.3
45.1
16.1
21.4
27.1
34.0
40.9
16.3
22.1
28.4
SHCkW
0.43
0.51
0.62
0.74
0.83
0.29
0.38
0.47
0.60
0.67
0.84
0.23
0.31
0.42
0.49
0.65
0.78
0.24
0.32
0.46
0.57
0.69
0.87
0.28
0.38
0.50
0.65
0.81
0.30
0.43
0.57
SHF
23.3
23.1
22.7
22.5
22.2
23.3
23.1
22.7
22.5
22.2
22.0
23.1
22.7
22.5
22.2
22.0
21.8
22.5
22.2
22.0
21.8
21.6
21.4
22.0
21.8
21.6
21.4
21.1
21.6
21.4
21.1
T/I kW
65.0
62.8
60.8
58.8
58.8
65.0
62.8
60.8
58.8
58.8
54.6
62.8
60.8
58.8
58.8
54.6
53.0
58.8
58.8
54.6
53.0
51.2
49.4
54.6
53.0
51.2
49.4
47.8
51.2
49.4
47.8
Q kW
40.0
28.3
33.0
38.9
45.2
50.7
18.8
24.4
29.3
36.0
40.8
47.4
14.7
19.0
25.1
29.9
36.5
42.6
14.3
19.3
25.6
31.2
36.5
44.0
15.4
20.7
26.4
33.0
39.8
15.7
21.3
27.7
SHCkW
)
0.44
0.53
0.64
0.77
0.86
0.29
0.39
0.48
0.61
0.69
0.87
0.23
0.31
0.43
0.51
0.67
0.80
0.24
0.33
0.47
0.59
0.71
0.89
0.28
0.39
0.52
0.67
0.83
0.31
0.43
0.58
SHF
In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “0.9kw” from “T/I value of this table”.
30.0
34.9
40.8
47.1
52.6
20.1
25.9
30.9
37.7
42.7
49.6
15.8
20.3
26.7
31.6
38.4
44.5
15.4
20.7
27.2
32.8
38.3
46.2
16.6
22.1
28.1
34.9
41.7
17.0
22.9
29.4
SHCkW
30.0
25.1
24.9
24.4
24.2
24.0
25.1
24.9
24.4
24.2
24.0
23.8
24.9
24.4
24.2
24.0
23.8
23.5
24.2
24.0
23.8
23.5
23.3
23.1
23.8
23.5
23.3
23.1
22.9
23.3
23.1
22.9
T/I kW
46.0
SHF
26.2
26.4
26.8
27.0
25.7
26.2
0.49
0.40
0.29
0.89
0.79
28.3
23.3
17.9
49.4
43.9
57.2
59.0
61.0
55.2
55.2
27.0
25.7
0.63
34.8
55.2
26.8
25.5
0.71
39.4
55.2
0.44
26.8
0.89
45.9
51.4
27.0
26.4
0.24
14.0
59.0
61.0
26.2
0.32
18.2
57.2
26.4
25.7
0.44
24.2
55.2
0.54
25.5
0.52
28.9
55.2
31.8
25.3
0.69
35.4
51.4
59.0
26.2
0.83
41.2
49.8
0.66
25.7
0.25
13.5
55.2
37.6
25.5
0.33
18.5
55.2
57.2
25.3
0.48
24.7
25.1
24.9
25.5
25.3
25.1
24.9
24.6
25.1
24.9
24.6
T/I kW
51.4
0.73
0.92
0.28
0.40
0.53
0.68
0.85
0.31
0.44
0.59
0.61
35.3
42.7
14.6
19.8
25.4
31.8
38.4
14.9
20.5
26.6
SHCkW
30.2
49.8
48.2
46.6
51.4
49.8
48.2
46.6
45.0
48.2
46.6
45.0
Q kW
- 34 -
60.0
17
58.2
17.9
19.0
0.75
45.3
60.4
17.9
0.74
46.0
62.2
18
19.2
19.4
19.7
19.9
20.1
20.3
19.4
19.7
0.64
0.57
0.45
0.37
0.28
0.80
0.71
43.2
38.3
31.3
20.5
53.5
47.9
67.2
67.2
69.4
71.8
73.8
67.2
67.2
18.1
18.4
18.6
18.8
19.0
19.2
18.4
18.6
0.63
0.56
0.45
0.36
0.28
0.79
0.71
43.9
38.8
31.9
26.8
21.0
54.5
48.8
69.2
69.2
71.6
73.8
76.0
69.2
69.2
21
22
23
24
20
21
19.0
19.2
0.49
0.41
36.2
31.1
73.8
76.0
23
24
20.1
20.3
0.49
0.41
35.4
30.4
71.8
73.8
COOLING
PEH-20MYA-EU
CAPACITY
TOTAL INPUT
SHC
AIR VOLUME
160
2,660
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
180
3,000
1.0
1.0
1.0
20.5
20.7
21.2
0.49
0.41
0.30
31.6
26.7
20.3
64.8
64.8
21.4
21.6
0.50
0.42
34.9
30.0
69.2
71.4
200
3,320
1.025
1.009
1.044
35.0
21.4
21.6
21.8
22.0
0.69
0.57
0.46
0.32
37.3
31.9
26.3
20.0
53.8
55.8
57.6
22.5
22.9
23.1
0.62
0.51
0.43
39.8
34.0
29.3
66.2
68.4
22.2
0.74
46.0
62.0
64.0
22.0
0.83
51.2
22.9
0.38
25.2
66.2
62.0
22.5
0.47
30.1
64.0
23.1
22.2
0.60
36.9
62.0
0.29
22.0
0.67
41.8
62.0
19.6
21.8
0.84
48.6
57.6
68.4
22.9
22.5
0.31
19.6
64.0
0.23
22.2
0.42
25.8
62.0
15.3
22.0
0.49
30.5
62.0
66.2
21.8
0.65
37.4
21.6
0.78
43.5
55.8
57.6
22.2
0.24
14.9
62.0
62.0
21.2
0.87
21.8
21.6
21.4
21.2
21.0
21.4
21.2
21.0
T/I kW
0.28
0.38
0.50
0.65
0.81
0.30
0.43
0.57
SHF
45.1
16.1
21.4
27.1
34.0
40.9
16.3
22.1
28.4
SHCkW
52.0
57.6
55.8
53.8
52.0
50.2
53.8
52.0
50.2
Q kW
40.0
24.2
24.6
24.8
0.64
0.53
0.44
38.9
33.0
28.3
62.8
65.0
24.0
0.77
45.2
58.8
60.8
23.8
0.86
50.7
0.39
24.4
62.8
58.8
24.6
0.48
29.3
60.8
24.8
24.2
0.61
36.0
58.8
0.29
24.0
0.69
40.8
58.8
18.8
23.5
23.8
0.87
47.4
54.6
65.0
24.6
24.2
0.31
19.0
60.8
0.23
24.0
0.43
25.1
58.8
14.7
23.8
0.51
29.9
58.8
62.8
23.5
0.67
36.5
54.6
23.3
0.80
42.6
23.8
0.33
19.3
58.8
53.0
23.5
0.47
25.6
54.6
24.0
23.3
0.59
31.2
53.0
0.24
23.1
0.71
36.5
51.2
14.3
22.9
0.89
44.0
49.4
58.8
23.5
23.3
23.1
22.9
22.7
23.1
22.9
22.7
T/I kW
0.28
0.39
0.52
0.67
0.83
0.31
0.43
0.58
SHF
15.4
20.7
26.4
33.0
39.8
15.7
21.3
27.7
SHCkW
54.6
53.0
51.2
49.4
47.8
51.2
49.4
47.8
Q kW
case of “indoor fan external static pressure: ESP = 200Pa”.
( InIf you
need “ESP = 100Pa”, please subtract “1.0kw” from “T/I value of this table”. )
21.2
0.61
40.8
20.7
0.73
47.1
64.8
67.0
20.5
0.81
52.6
21.4
0.37
25.9
69.2
64.8
21.2
0.46
30.9
67.0
21.6
20.7
0.58
37.7
64.8
0.28
20.5
0.66
42.7
64.8
20.1
20.3
0.82
49.6
60.2
71.4
21.4
0.23
15.8
69.2
67.0
20.3
0.64
38.4
20.1
0.76
44.5
58.2
60.2
20.7
0.24
15.4
20.5
64.8
0.32
20.3
0.45
27.2
60.2
20.7
20.1
0.56
32.8
58.2
64.8
19.9
0.68
38.3
56.2
20.3
20.1
19.9
19.9
19.7
19.9
19.9
19.7
T/I kW
19.9
0.28
0.38
0.50
0.64
0.80
0.30
0.42
0.56
SHF
OUTDOOR DB˚C
0.85
16.6
22.1
28.1
34.9
41.7
17.0
22.9
29.4
SHCkW
30.0
46.2
54.2
60.2
58.2
56.2
54.2
52.2
56.2
54.2
52.2
Q kW
T/I:TOTAL INPUT
19.9
0.60
41.4
69.4
26.4
SHC:SENSIBLE HEAT CAPACITY
18.8
0.59
42.3
71.6
22
20
0.80
50.1
62.4
0.79
50.9
64.2
19
20.1
0.23
16.2
71.8
19.0
19.9
0.22
0.30
16.6
73.8
23
20.8
69.4
18.8
0.30
21.2
71.6
22
19.7
0.41
27.4
67.2
18.6
0.40
27.9
69.2
21
19.4
0.48
32.5
67.2
18.4
0.48
33.0
69.2
20
19.2
0.63
39.3
18.1
0.62
39.8
64.2
62.4
19
19.7
0.24
15.9
67.2
18.6
0.24
16.5
19.4
69.2
0.32
21
21.2
67.2
18.4
0.32
21.9
69.2
20
19.2
0.45
27.9
62.4
18.1
0.44
19.0
0.56
33.6
60.4
28.5
18.8
18.6
19.2
19.0
18.8
18.6
18.4
18.8
18.6
18.4
T/I kW
0.67
0.84
0.27
0.38
0.50
0.63
0.78
0.30
0.42
0.56
SHF
39.0
58.2
47.1
17.1
22.8
28.9
35.7
42.3
17.6
23.6
30.1
SHCkW
64.2
17.9
56.2
62.4
18.1
17.7
60.4
58.2
56.2
17.9
17.9
17.7
54.0
56.2
17.7
17.5
54.0
Q kW
17.5
T/I kW
17.9
0.67
0.83
0.27
0.37
0.49
0.63
0.77
0.30
0.42
0.55
SHF
0.55
39.9
47.8
17.4
23.2
29.3
36.2
43.1
18.0
24.1
30.8
SHCkW
25.0
34.3
19
57.8
16
62.2
64.2
19
18
62.2
57.8
16
18
55.6
15
60.0
60.0
17
17
57.8
55.6
15
16
Q kW
WB ˚C
20.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
PEH-20MYA-EU
Cooling Capacity (Standard Air Flow)
61.0
59.0
57.2
55.2
55.2
61.0
59.0
57.2
55.2
55.2
51.4
59.0
57.2
55.2
55.2
51.4
49.8
55.2
55.2
51.4
49.8
48.2
46.6
51.4
49.8
48.2
46.6
45.0
48.2
46.6
45.0
Q kW
46.0
27.0
31.8
37.6
43.9
49.4
17.9
23.3
28.3
34.8
39.4
45.9
14.0
18.2
24.2
28.9
35.4
41.2
13.5
18.5
24.7
30.2
35.3
42.7
14.6
19.8
25.4
31.8
38.4
14.9
20.5
26.6
SHCkW
SHF
0.44
0.54
0.66
0.79
0.89
0.29
0.40
0.49
0.63
0.71
0.89
0.24
0.32
0.44
0.52
0.69
0.83
0.25
0.33
0.48
0.61
0.73
0.92
0.28
0.40
0.53
0.68
0.85
0.31
0.44
0.59
26.8
26.6
26.1
25.9
25.5
26.8
26.6
26.1
25.9
25.5
25.3
26.6
26.1
25.9
25.5
25.3
25.1
25.9
25.5
25.3
25.1
24.8
24.6
25.3
25.1
24.8
24.6
24.4
24.8
24.6
24.4
T/I kW
- 35 -
17.2
17.4
17.6
17.6
17.8
17.2
17.4
0.62
0.52
0.42
0.34
0.27
0.77
0.66
45.3
39.8
33.1
27.6
22.1
56.4
50.5
73.4
76.2
79.0
81.8
82.0
73.4
76.2
20
21
22
23
24
20
21
81.2
81.6
78.8
76.0
73.2
81.2
81.6
78.8
76.0
73.2
70.4
81.6
78.8
76.0
73.2
70.4
67.6
76.0
73.2
70.4
67.6
64.8
62.0
70.4
67.6
64.8
62.0
59.2
64.8
62.0
59.2
32.2
37.4
44.0
50.3
56.2
21.9
27.5
33.0
39.7
45.2
52.5
17.2
22.0
28.6
33.8
40.8
47.4
17.5
23.0
29.7
35.5
41.4
49.2
17.9
23.8
30.1
37.1
44.4
18.6
24.9
31.9
Q kW SHC kW
0.0
T/I kW
17.7
18.0
18.2
17.7
18.0
18.2
18.5
18.5
18.0
18.2
18.5
18.5
18.7
18.9
18.5
18.5
18.7
18.9
19.2
19.4
18.5
18.7
18.9
19.2
19.4
19.4
18.7
18.9
19.2
19.4
19.4
SHF
0.54
0.40
0.29
0.75
0.60
0.46
0.35
0.25
0.79
0.64
0.53
0.42
0.31
0.23
0.70
0.58
0.46
0.38
0.28
0.21
0.75
0.62
0.52
0.42
0.34
0.27
0.77
0.66
0.56
0.46
0.40
AIR VOLUME
CAPACITY
TOTAL INPUT
SHC
PEH-20MYA-EU
COOLING
160
2,660
0.976
0.991
0.963
CMM
L/S
Factor for Various Air Flow
3,000
1.0
1.0
1.0
180
5.0
32.1
37.2
43.7
50.1
55.9
21.8
27.4
32.8
39.5
45.0
52.3
17.1
21.9
28.5
33.7
40.6
47.2
17.4
22.9
29.5
35.4
41.2
49.0
17.8
23.7
30.0
36.9
44.2
18.6
24.8
31.7
19.7
19.2
19.4
19.7
20.0
20.2
19.4
19.7
20.0
20.2
20.2
20.5
20.0
20.2
20.2
20.5
20.7
21.0
20.2
20.2
20.5
20.7
21.0
21.3
20.2
20.5
20.7
21.0
21.3
0.29
0.75
0.60
0.47
0.35
0.25
0.80
0.64
0.53
0.42
0.31
0.23
0.70
0.58
0.46
0.38
0.28
0.21
0.75
0.62
0.52
0.42
0.34
0.27
0.77
0.66
0.56
0.46
0.40
200
79.0
80.4
77.6
74.8
72.0
79.0
80.4
77.6
74.8
72.0
69.2
80.4
77.6
74.8
72.0
69.2
66.4
74.8
72.0
69.2
66.4
63.6
60.8
69.2
66.4
63.6
60.8
58.0
63.6
60.8
58.0
31.7
36.9
43.3
49.6
55.4
21.5
27.2
32.5
39.3
44.6
51.8
16.9
21.7
28.3
33.4
40.4
46.8
17.1
22.5
29.2
35.0
40.8
48.6
17.7
23.5
29.7
36.7
43.8
18.4
24.6
31.4
Q kW SHCkW
T/I kW
18.5
18.7
19.0
18.5
18.7
19.0
19.2
19.5
18.7
19.0
19.2
19.5
19.7
19.7
19.2
19.5
19.7
19.7
19.9
20.2
19.5
19.7
19.7
19.9
20.2
20.4
19.7
19.7
19.9
20.2
20.4
SHF
0.54
0.40
0.29
0.76
0.60
0.47
0.35
0.26
0.80
0.64
0.53
0.42
0.31
0.23
0.70
0.58
0.46
0.38
0.28
0.21
0.75
0.62
0.53
0.42
0.34
0.27
0.77
0.66
0.56
0.46
0.40
10.0
)
16
17
21
22
17.1
17.1
16.8
17.1
17.1
17.3
17.5
17.1
17.1
17.3
17.5
17.7
17.9
17.3
17.5
17.7
17.9
18.1
18.4
17.5
17.7
17.9
18.1
18.4
18.4
17.7
17.9
18.1
18.4
18.4
0.41
0.29
0.76
0.61
0.47
0.36
0.26
0.81
0.65
0.53
0.42
0.31
0.23
0.71
0.59
0.47
0.39
0.29
0.22
0.76
0.63
0.54
0.43
0.36
0.27
0.78
0.68
0.58
0.48
0.40
24.3
18.2
43.4
36.4
29.5
23.3
17.5
48.2
40.3
34.6
28.8
22.2
16.8
46.4
40.1
33.2
28.1
21.4
16.7
51.4
44.3
39.0
32.2
27.0
21.3
54.9
49.2
42.8
36.5
31.4
59.8
62.5
57.0
59.8
62.5
65.3
68.0
59.8
62.5
65.3
68.0
70.8
72.5
65.3
68.0
70.8
72.5
74.2
75.9
68.0
70.8
72.5
74.2
75.9
77.6
70.8
72.5
74.2
75.9
77.6
54.4
54.8
55.2
55.4
55.6
55.8
56.0
56.2
56.2
56.6
56.8
57.0
57.2
17.6
17.4
17.4
17.2
17.0
16.8
16.8
16.6
16.4
16.1
16.1
15.7
15.9
14.1
13.9
13.9
13.7
13.7
13.5
13.5
13.5
13.2
13.2
13.0
13.0
13.0
62.2
62.8
63.2
63.4
63.6
64.0
64.2
64.4
64.6
65.0
65.2
65.4
65.6
19.9
19.7
19.5
19.3
19.0
18.8
18.8
18.6
18.4
18.2
18.0
17.6
17.8
T/I kW
10.0
OUTDOOR WB ˚C
40.6
40.8
41.0
41.2
41.4
41.6
41.8
42.0
42.2
42.4
42.6
42.6
42.8
PEH-20MYA-EU
HEATING
15.7
15.5
15.5
15.3
15.1
15.1
14.9
14.7
14.7
14.5
14.5
14.3
14.3
T/I kW
0.0
70.8
71.2
71.8
72.2
72.4
72.8
73.2
73.6
73.8
74.0
74.2
74.4
74.6
Q kW
22.4
22.1
21.7
21.5
21.3
21.3
21.1
20.9
20.7
20.5
20.1
19.7
19.9
T/I kW
15.0
47.2
47.4
47.8
48.0
48.2
48.4
48.6
48.6
48.8
49.0
49.2
49.0
49.6
Q kW
L/S
CMM
CAPACITY
TOTAL INPUT
AIR VOLUME
0.989
1.025
2,660
160
1.0
1.0
3,000
180
Factor for Various Air Flow
(
12.6
12.6
12.4
12.4
12.4
12.4
12.2
12.2
12.2
12.2
12.0
12.0
12.0
Q kW T/I kW Q kW
5.0
34.6
34.8
35.0
35.2
35.4
35.6
35.8
36.0
36.2
36.4
36.4
36.6
36.8
T/I kW
-5.0
OUTDOOR WB ˚C
Q kW T/I kW Q kW
-10.0
1.008
0.984
3,320
200
* Q:HEATING CAPACITY T/I:TOTAL INPUT
In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “1.0kw” from “T/I
value of this table”.
27
26
25
24
23
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
27
26
25
24
23
20
19
18
15
16.8
0.55
31.1
DB ˚C
T/I kW
SHF
INDOOR
PEH-20MYA-EU
Heating Capacity
(Standard Air Flow)
57.0
Q kW SHCkW
15.0
In case of “indoor fan external static pressure: ESP = 200Pa”.
If you need “ESP = 100Pa”, please subtract “1.0kw” from “T/I value
of this table”.
19.4
0.40
(
19.2
0.54
T/I:TOTAL INPUT
80.2
81.2
78.4
75.6
72.8
80.2
81.2
78.4
75.6
72.8
70.0
81.2
78.4
75.6
72.8
70.0
67.2
75.6
72.8
70.0
67.2
64.4
61.6
70.0
67.2
64.4
61.6
58.8
64.4
61.6
58.8
T/I kW
SHF
OUTDOOR DB˚C
Q kW SHCkW
3,320
1.025
1.009
1.044
SHC:SENSIBLE HEAT CAPACITY
17.8
17.0
0.75
52.7
70.6
19
0.40
17.6
0.21
17.3
81.8
23
32.4
17.6
0.28
22.1
79.0
22
82.0
17.4
0.38
28.7
76.2
21
24
17.2
0.46
33.9
73.4
20
17.6
17.0
0.58
40.9
70.6
19
0.46
17.0
0.70
47.5
67.8
18
37.6
17.4
0.23
17.6
76.2
21
81.8
17.2
0.32
23.2
73.4
20
23
17.0
0.42
29.8
70.6
19
17.6
17.0
0.53
35.7
67.8
18
0.56
16.7
0.64
41.6
65.0
17
44.2
16.5
0.79
49.4
62.2
16
79.0
17.0
0.26
18.0
70.6
19
22
17.0
0.35
23.9
67.8
16.5
0.60
18
16.3
0.75
16.7
37.2
16.7
0.29
0.46
62.2
16
44.6
16.5
0.40
30.2
59.4
15
18.7
16.3
0.54
65.0
65.0
17
25.0
32.0
T/I kW
SHF
17
62.2
16
59.4
Q kW SHCkW
-5.0
Note1. * Q:COOLING CAPACITY
30
28
26
24
22
20
15
DB˚C WB˚C
INDOOR
PEH-20MYA-EU
(Use for low ambient cooling parts)
Cooling Capacity (Standard Air Flow)
)
CAPACITY REDUCTION RATIO DUE TO CHANGES IN PIPING LENGTH
(1) Cooling capacity
PE-7,8,15MYC-EU
PEH-7,8,15MYA-EU
Capacity ratio
1.0
0.9
0
5
10
15
20
25
30
35
40
45
50
40
45
50
Equivalent piping length (m)
PE-10,20MYC-EU
PEH-10,20MYA-EU
Capacity ratio
1.0
0.9
0
5
10
15
20
25
30
35
Equivalent piping length (m)
(2) Heating capacity
Model name
Equivalent piping length
PEH-7, 8, 10, 15, 20MYA
- 36 -
~30m
30~50m
1.0
0.995
OPERATION RANGE
The range of working temperatures is as below.
Make sure which unit you are using and confirm the range of application.
Cooling
Heating (PEH only)
40
30
Range for
continuous operation
20
10
0
-5
-10
10
15
20
24 25
30
Indoor temp.(˚CWB)
Range for
continuous operation
Use for low ambient
cooling parts
(without PU-15,20)
Outdoor temp.(˚CWB)
Outdoor temp.(˚CDB)
50
46
15
10
5
Range for
continuous operation
0
-5
-10
10
15
Note:
As an applicable humidity outside standard for both indoors and outdoors, and
indoor return air we recommend use within a range of 35-80% relative humidity.
However, it is a condition that there is no be dewy in surfaces of electric parts.
- 37 -
20
25 27 30
Indoor temp.(˚CDB)
Caution:
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
FAN PERFORMANCE
PE-7MYC-EU
PEH-7MYA-EU
PEH-5MYA-EU
Fan Performance Curve
50Hz
(Pa)
450
450
Recommended Range
400
400
Fan speed
(rpm)
350
Recommended Range
Fan speed (rpm)
1400
350
1300
1300
300
1200
Total static pressure
Total static pressure
Fan Performance Curve
50Hz
(Pa)
For connection
operation line
250
1100
200
1000
150
900
For connection
operation line
For Hi speed
operation line
300
1200
250
200
150
1100
For Low speed
operation line
1000
900
800
100
Inte
r
100
SP
nal
Inte
50
0
35
580
40
45
750
50
55 (CMM)
920 (L/S)
48 50
800
Air flow
factory pre setting ESP = 125Pa
450
(Pa)
Fan speed (rpm)
1400
400
For connection
operation line
350
Total static pressure
Total static pressure
300
1200
150
1100
For connection
operation line
900
800
100
r na
Fan Performance Curve
50Hz
Fan speed (rpm)
1400
For
connection
operation line
1300
300
1200
250
200
150
Inte
70
Recommended Range
1300
1000
65
450
Recommended Range
350
200
60
1000
PE-10MYC-EU
PEH-10MYA-EU
Fan Performance Curve
50Hz
(Pa)
55
Air flow
factory pre setting ESP = 125Pa
PE-8MYC-EU
PEH-8MYA-EU
250
l SP
50
0
400
r na
1100
For connection
1000 operation line
al
900
SP
n
er
t
l SP
In
100
50
50
0
0
50
830
55
60
1000
65
70
1170
75
80 (CMM)
1330 (L/S)
Air flow
factory pre setting ESP = 125Pa
65 70
1080
80
1330
90
100 (CMM)
1670 (L/S)
Air flow
factory pre setting ESP = 125Pa
- 38 -
75 (CMM)
1250 (L/S)
PE-15MYC1-EU
PEH-15MYA-EU
Total static
pressure
(Pa)
200
Fan Performance Curve
50Hz
Recommended Range
(Pa)
1000
300
Fan speed
(rpm)
1300
Total static pressure
800
600
3.7kW
400
L/S
FAN SPEED
rpm
PULLEYSIZE
(MOTOR SIDE)
mm
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
1100
PULLEYSIZE
mm
(MOTOR SIDE)
inch
1000
2.2kW
900
800
200
CMM
1200
500
400
Model
600
700
600
500
l SP
a
Intern
700
0
110
1830
120
130
2170
140
150
2500
160
170 (CMM)
2830(L/S)
800
Air flow
factory pre setting ESP = 200Pa
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
110
1830
768
139.7
5.5
254
10
B45
2.2
898
114.3
4.5
177.8
7
B38X2
2.2
942
152.4
6
228.6
9
B44
2.2
1008
127
5
177.8
7
B37X2
3.7
1119
139.7
5.5
177.8
7
B38X2
3.7
1190
127
5
152.4
6
B36X2
3.7
1258
177.8
7
203.2
8
B42
3.7
Airflow
PE-15MYC1-EU, PEH-15MYA-EU
140
120
130
150
2330
2000
2170
2500
768
768
768
768
139.7
139.7
139.7
139.7
5.5
5.5
5.5
5.5
254
254
254
254
10
10
10
10
B45
B45
B45
B45
2.2
2.2
2.2
2.2
898
898
898
898
114.3
114.3
114.3
114.3
4.5
4.5
4.5
4.5
177.8
177.8
177.8
177.8
7
7
7
7
B38X2 B38X2 B38X2 B38X2
2.2
2.2
2.2
2.2
942
942
971
942
152.4
152.4
139.7
152.4
6
6
5.5
6
228.6
228.6
203.2
228.6
9
9
8
9
B44
B44
B40X2
B44
2.2
2.2
3.7
2.2
1008
1008
1067
1008
127
127
152.4
127
5
5
6
5
177.8
177.8
203.2
177.8
7
7
8
7
B37X2 B37X2 B37X2 B40X2
3.7
3.7
3.7
3.7
1119
1119
1119
1119
139.7
139.7
139.7
139.7
5.5
5.5
5.5
5.5
177.8
177.8
177.8
177.8
7
7
7
7
B38X2 B38X2 B38X2 B38X2
3.7
3.7
3.7
3.7
1190
1190
1190
127
127
127
5
5
5
152.4
152.4
152.4
6
6
6
B36X2 B36X2 B36X2
3.7
3.7
3.7
-
160
2670
898
114.3
4.5
177.8
7
B38X2
2.2
971
139.7
5.5
203.2
8
B40X2
3.7
1067
152.4
6
203.2
8
B40X2
3.7
1119
139.7
5.5
177.8
7
B38X2
3.7
-
Std.
PE-20MYC-EU
PEH-20MYA-EU
Total static
pressure
(Pa)
200
Fan Performance Curve
(Pa)
Recommended Range
1000
Fan speed
(rpm)
300
1300
5.5
Total static pressure
800
kW
1200
400
600 1100
1000
400
500
3.7kW
900
800
700
200
600
P
rnal S
Inte
600
700
0
150 160
2500
180
3000
195200
3300
220
240 (CMM)
4000(L/S)
Air flow
factory pre setting ESP = 200Pa
800
Model
CMM
L/S
FAN SPEED
rpm
PULLEYSIZE
(MOTOR SIDE)
mm
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
Std.
- 39 -
mm
(FAN SIDE)
150
2500
627
127
5
279.4
11
B44X2
3.7
768
139.7
5.5
254
10
B43X2
3.7
942
152.4
6
228.6
9
B42X2
3.7
1008
127
5
177.8
7
B37X2
3.7
1119
139.7
5.5
177.8
7
B37X2
5.5
1229
152.4
6
177.8
7
B38X2
5.5
1258
177.8
7
203.2
8
B41X2
5.5
Airflow
PE-20MYC-EU, PEH-20MYA-EU
200
160
180
220
3330
2670
3000
3670
692
627
692
127
127
127
5
5
5
254
279.4
254
11
10
10
B44X2 B42X2 B42X2
3.7
3.7
3.7
768
773
773
773
139.7
127
127
127
5.5
5
5
5
254
228.6
228.6
228.6
10
9
9
9
B43X2 B40X2 B40X2
B40X2
3.7
3.7
3.7
3.7
942
942
942
942
152.4
152.4
152.4
152.4
6
6
6
6
228.6
228.6
228.6
228.6
9
9
9
9
B42X2 B42X2 B42X2
B41X2
3.7
3.7
5.5
3.7
1008
1008
1067
1067
127
127
152.4
152.4
5
5
6
6
177.8
177.8
203.2
203.2
7
7
8
8
B37X2 B37X2 B39X2
B39X2
3.7
3.7
5.5
5.5
1119
1119
1119
1119
139.7
139.7
139.7
139.7
5.5
5.5
5.5
5.5
177.8
177.8
177.8
177.8
7
7
7
7
B37X2 B37X2 B37X2
B37X2
5.5
5.5
5.5
5.5
1229
1229
1229
152.4
152.4
152.4
6
6
6
177.8
177.8
177.8
7
7
7
B38X2 B38X2 B38X2
5.5
5.5
5.5
1258
1258
177.8
177.8
7
7
203.2
203.2
8
8
B41X2 B41X2
5.5
5.5
-
240
4000
773
127
5
228.6
9
B40X2
3.7
942
152.4
6
228.6
9
B41X2
5.5
1067
152.4
6
203.2
8
B39X2
5.5
-
170
2830
898
114.3
4.5
177.8
7
B38X2
2.2
971
139.7
5.5
203.2
8
B40X2
3.7
1067
152.4
6
203.2
8
B40X2
3.7
1119
139.7
5.5
177.8
7
B38X2
3.7
-
Pulley outside dimensions are shown below: (Unit : mm)
(1) Shape of belt groove
e
f
K0
Shape of
V-belt
Nominal
Dia. øP.C
B
Over 125
Under 160
Over 160
Under 200
Over 200
a
(˚)
W
34
15.86
36
16.07
38
16.29
øP.C
r3
r1
a
r2 r2
K
w
L0
L0
K
K0
e
f
r1
r2
r3
V-belt
thickness
(Reference)
12.5
5.5
9.5
19.0
12.5
0.2~0.5
0.5~1.0
1~2
11
Sectional plan of V-belt
11.0mm
16.5mm
40˚
B type
(2) Shape of motor pulley boss (Unit : mm)
C
B
A
MOTOR
CAPACITY
(kW)
A
+0.028
2.2, 3.7
28 + 0.007
5.5
38 + 0.007
+0.028
B
+ 0.128
31 + 0.007
+ 0.128
41 + 0.009
- 40 -
C
8
+0.018
-0.018
+0.018
10 -0.018
SOUND DATA
Indoor units
Sound Levels
MODEL
PEH-5MYA-EU
PE-7MYC-EU
PEH-7MYA-EU
PE-8MYC-EU
PEH-8MYA-EU
PE-10MYC-EU
PEH-10MYA-EU
PE-15MYC1-EU
PEH-15MYA-EU
PE-20MYC-EU
PEH-20MYA-EU
OCTAVE BAND FREQ. Hz
SPL
dB(A)
63Hz
125Hz
250Hz
500Hz
1000Hz
2000Hz
4000Hz
8000Hz
55
60.5
57.5
57.5
52.5
50.5
43
34.5
28.5
55
62
60
54
53
50
42.5
37
31.5
56
63
61
55
54
51
43.5
38
32.5
59
62
62.5
58.5
59.5
53
48
43.5
36
61
25
40
47
52
55
57.5
52
36.5
62
32
44
49
53.5
56.5
57.5
53
51
Outdoor units
Sound Levels
OCTAVE BAND FREQ. Hz
SPL
dB(A)
63Hz
125Hz
250Hz
500Hz
1000Hz
2000Hz
4000Hz
8000Hz
PUH-5MYE1-EU
57
68
58
57
52.5
52
47.5
49
40
PU-7MYC1-EU
PUH-7MYC2-EU
PU-8MYC1-EU
PUH-8MYC2-EU
65
62
63.5
62
62
60
57.5
54
54
65
62
63.5
62
62
60
57.5
54
54
PUH-8MYE1-EU
PU-10MYC1-EU
PUH-10MYC2-EU
65
45.4
58
58
58.5
61
60
51.5
47
65
64.5
65
64
62.5
60
57
54.5
53
PUH-10MYE1-EU
65
45.4
58
58
58.5
61
60
51.5
47
PU-15MYC1-EU
67
68
72
70
65
60
57
53
49.5
PU-20MYC1-EU
68
66
69
70.5
65
62
59
56.5
53
PUH-15MYC2-EU
69
43
51
59
64
65
64
55
50.5
PUH-20MYC2-EU
69
43
51
59
64.5
65
64
55.5
51.5
MODEL
Position measurement
Indoor unit
Outdoor unit
PE(H)
PU(H)
1m
Inlet
Outlet
1m
1m
- 41 -
Service
panel side
APPROXIMATION FOR SOUND POWER LEVEL AT SUPPLY DUCT FLANGE OF UNIT
Air volume
125Hz
250Hz
500Hz
1000Hz
2000Hz
4000Hz
<CMM>
External
static
pressure
<Pa>
PE(H)-7
60
125
77.2
74.7
71.6
69.9
65.7
61.4
PE(H)-8
70
125
79.4
76.9
73.9
72.4
68.4
64.3
PE(H)-10
90
125
81.2
78.7
75.7
74.3
70.4
66.5
PE(H)-15
140
200
83.4
80.9
78.0
76.6
72.7
68.9
PE(H)-20
180
200
84.5
82.1
79.1
77.7
73.8
70.1
MODEL
Note: This is very rough calculation, Noise level will be changed by operation condition or installation.
- 42 -
OUTLINE DIMENSIONS
(unit; mm)
PEH-5
POWER SUPPLY
CABLE ENTRY ø27
(Bottom side)
104
130
130
130
130
130
66
HOLES:18-ø3.1
AIR INLET DUCT
FLANGE
40
55
50
105
960
20
200
40
199
40
OPTIONAL PARTS
CABLE ENTRY ø27
(Bottom side)
34
782
135 66
CONTROL
CABLE ENTRY ø27
(Bottom side)
*Except: Drain size (unit; inch)
20
131
CONTROL BOX
55
AIR OUTLET DUCT
FLANGE
130
130
130
55
15
HOLES:14-ø3.1
HOLES:4-ø12
1095
650
50
40
920
15
210
210
98
250
428
REFRIGERANT
PIPE ø12.7
(1/2) Braze
14
AIR OUTLET
25
382
280
100 100
130
130
42
33
40
500
REFRIGERANT
PIPE ø19.05
(3/4) Braze
25
70
42
20
156
344
70
15
95 152
AIR INLET
1000
530
944
562
DRAIN:RC1
PE(H)-7,8
104
POWER SUPPLY
CABLE ENTRY 27
(Bottom side)
1102
130
130
130
130
34
130
130
130
HOLES:24- 3.1
31
130
105 40
199
1280
20
20
200
(Bottom side)
AIR INLET DUCT
FLANGE
50
55
OPTIONAL PARTS
CABLE ENTRY 27
40
27
(Bottom side)
40
CONTROL
CABLE ENTRY
135 31
HOLES:22- 3.1
45
AIR OUTLET DUCT
FLANGE
REFRIGERANT PIPE
25.4
(1) Braze
25
130
130
130
45
HOLES:4- 12
1000
40
120
250
REFRIGERANT PIPE
15.88
(5/8) Braze
382
100 100
25
1240
120
AIR
OUTLET
14
70
280
42
130
98
40
15
130
130
156
344
33
130
1320
70
42
20
15
95 152
428
AIR
INLET
530
130
1415
650
50
130
15
131
CONTROL BOX
562
1264
DRAIN:Rc1
- 43 -
PE(H)-10
104
POWER SUPPLY
CABLE ENTRY 27
(Bottom side)
1302
66 130
135
130
130
130
34
130
130
130
130
HOLES:26- 3.1
130 66
CONTROL
105 40
(Bottom side)
1480
20
20
200
40
(Bottom side)
199
40
OPTIONAL PARTS
CABLE ENTRY 27
AIR INLET DUCT
FLANGE
50
27
55
CABLE ENTRY
HOLES:22- 3.1
45
130
130
130
AIR OUTLET DUCT
FLANGE
HOLES:4- 12
25
AIR
OUTLET
40
98
220
REFRIGERANT PIPE
15.88
(5/8) Braze
250
382
100 100
280
45
1440
1000
220
REFRIGERANT PIPE
28.6
(1-1/8) Braze
25
70
20
40
42
130
42
130
1520
70
15
130
156
344
1464
33
562
DRAIN:Rc 1
PE(H)-15
70
1690
1418
120
49
1300=130X10
59
AIR INLET DUCT
FLANGE
63
50
POWER SUPPLY
CABLE ENTRY 27
(BOTTOM SIDE)
3.1
15
HOLES:34-
59
130
55
CONTROL
CABLE ENTRY 27
(BOTTOM SIDE)
620
40
40
190
REFRIGERANT
PIPE 15.88 (5/8)
Braze
REFRIGERANT
PIPE 25.4 (1)
25
Braze OPTIONAL PARTS
REFRIGERANT CABLE ENTRY 27
PIPE 15.88 (5/8)
Braze
CONTROL BOX
REFRIGERANT
PIPE 25.4 (1)
Braze
130
AIR OUTLET DUCT
FLANGE
46
910=130X7
484
VIEW A
12
63
HOLES:4-
15
34
81
25
1637
1002
46
101
HOLES:24-
3.1
865
1587
- 44 -
50
19
23
110
110
600
110
110
130
50
DRAIN: Rc1
110
130
706
130
207
276
A
36
AIR OUTLET
50
15
27
37
36
462
74 91
191
AIR OUTLET
74
AIR INLET
746
87
69
15
26
428
95 152
AIR
INLET
15
130
14
530
130
1615
650
50
130
15
131
CONTROL BOX
AIR INLET
PE(H)-20
70
1993
1648
193
44
49
1560=130X12
AIR INLET DUCT
FLANGE
63
50
POWER SUPPLY
CABLE ENTRY
27
(BOTTOM SIDE)
3.1
15
HOLES:38-
44
130
620
40
12
63
HOLES:4-
130
21
1170=130X9
536
81
25
1940
25
CABLE ENTRY 27
REFRIGERANT
CONTROL BOX
PIPE 15.88 (5/8)
Braze
REFRIGERANT
PIPE 28.6 (1-1/8)
Braze
AIR OUTLET DUCT
FLANGE
15
190
44
40
REFRIGERANT
PIPE 15.88 (5/8)
Braze
REFRIGERANT
PIPE 28.6 (1-1/8)
Braze OPTIONAL PARTS
55
CONTROL
CABLE ENTRY 27
(BOTTOM SIDE)
1212
21
142
HOLES:28-
3.1
865
130
26
1890
50
DRAIN:Rc 1
- 45 -
50
36
207
269.5
A
19
23
110
110
600
110
706
AIR OUTLET
50
15
110
130
167
AIR OUTLET
90
AIR INLET
746
110
37
36
130
90 89.5
462
50
27
69
15
87
VIEW A
AIR INLET
PUH-5
75
AIR INLET
400
AIR INLET
75
Holes :4-12 × 20
21
1040
550
AIR OUTLET
21
1000
1175
SERVICE PANEL
131
126
REFRIGERANT PIPE
ø12.7 (1/2) Flare
CABLE ENTRY
21
Hole : ø15
Holes : 2-ø15
75
18
PU(H)-7,8,10
(Upper blow)
AIR INLET
275
275
13
400
42
75
42
84 75
REFRIGERANT PIPE
ø19.05 (3/4) Flare
200
CABLE ENTRY 25X40
1000
350
13
724
AIR INLET
700
AIR OUTLET
Holes: 4-12 × 20
SERVICE PANEL
120
980
AIR INLET
34
28
100
235
175
REFRIGERANT PIPE
PU(H)- 7,8:ø25.4(1) Flange
PU(H)- 10:ø28.6(1-1/8)
Flange
875
REFRIGERANT PIPE
ø15.88 (5/8) Flare
72
115
25
160
25
1400
540
700
1450
25
ACCESSORY PIPE
- 46 -
25
PUH-8,10
(Side blow)
400
75
AIR INLET
Holes : 4-12 × 20
75
AIR INLET
21
1290
21
AIR OUTLET
550
1250
1175
SERVICE PANEL
REFRIGERANT PIPE
ø15.88(5/8) Flare
130
CABLE ENTRY
REFRIGERANT PIPE
PUH-8:ø25.4(1) Flange
PUH-10:ø28.6(1-1/8) Flange
44
49
Hole : ø15
400
75
56
42
75
42
84 75
Holes : 2-ø15
275
275
ACCESSORY PIPE
PU-15
23
AIR INLET
23
1046
AIR INLET
AIR INLET
AIR OUTLET
998
998
HOLES: 4-Uø15
SERVICE PANEL
1070
REFRIGERANT PIPE
ø25.4(1) Flange
ACCESSORY PIPE
170 75 85 75
78
No.1
No.2
85
0
169
242
100
CONTROL
CABLE ENTRY ø27
50
137
721
995
POWER SUPPLY
CABLE ENTRY ø43
- 47 -
137
1230
REFRIGERANT PIPE
ø15.88(5/8) Flare
PU-20
464
35
AIR INLET
AIR INLET
464
AIR INLET
No.1
17
35
30
52
48
HOLES: 6-ø15
No.2
2036
17
ACCESSORY PIPE
REFRIGERANT PIPE
ø15.88(5/8) Flare
REFRIGERANT PIPE
ø28.6(1-1/8) Flange
1996
160
SERVICE PANEL
CONTROL
CABLE ENTRY ø27
801
POWER SUPPLY
CABLE ENTRY ø47
392
81
85
213 80
961
AIR OUTLET
998
756475
750
130
PUH-15,20
200
Holes : 4-12 × 20
27
830
2005
478.5
27
994
CONTROL BOX
REFRIGERANT PIPE
ø15.88 (5/8) Flare
1042
1200
SERVICE PANEL
REFRIGERANT PIPE
PUH-15:ø25.4(1) Flange
PUH-20:ø28.6(1-1/8) Flange
1080
26
74
No.1
No.2
195
120
ACCESSORY PIPE
66
911
54
128
1951
2059
- 48 -
54
Note:
In the case of installation are shown below, it is possible to use the unit by connecting the duct.
However, the pressure loss must be 30Pa (3mmAq) or less.
Duct work is local supply.
DUCT
DUCT
- 49 -
WIRING DIAGRAMS
PE-7MYC-EU /PU-7MYC1-EU (STANDARD)
OUTDOOR
TB1
L2
RED
F3(3.15A)
BLUE
WHITE
BLACK
BLACK
MC
51F2
RED
L1
WHITE
RED
PE
51F2
17
CIRCUIT BREAKER
(FIELD SUPPLY)
PU-7MYC1-EU···50A
51C
RED
WHITE
L3
N
52C
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
52C
BLACK
49C
18
C14
RED
2
3
WHITE
1
2
3
RED
BLACK
MF2
(*2)
VIOLET
TB5
1
16 VIOLET
1 C11
15
BLACK
MF3
(*2)
C21
15
63H
WHITE
GRAY
2
19
CZ2
C13
51C
1
22
VIOLET
CZ2
CH
14
20
3
30
CZ
21
GRAY
14
CR2
VIOLET 52C
30
CZ
TB6
N
N
(*1) JUMPER
INDOOR
TB2
L
POWER SUPPLY
220~240VAC
~PE
50Hz
TB4
51F1
52F
RED
L TB4
Hi
C01 RED
6
6
5
BROWN
2
Low
BLUE
RED
F1 (3.15A)
L
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-7MYC-EU···15A
RED
NOTE 5
C03
C03
C04
1
TB4
GRAY
1
19
PINK
GRAY
1
26L
15
3
15
TB3
15
C03
3
3
OUTDOOR
3
TB4
30FZ
18
16
C16
COMP1
FZ
8
CZ1
24VAC(N)
AC
24V
Tr
52F
21
PAC-204RC
1
RED SILVER
PINK
4
1
1
C
PINK
F2
(3.15A)
51F1
17
BLUE
C01 PINK 20
MF1 5
6
FAN HI
PE
7
SW2(FIELD SUPPLY)
24VAC(L)
N
(*2)
1
7
CZ2
3
2
CR1
2
PINK
GRAY
14
GRAY
3
52F
30
FZ
BLUE
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49C
51C
51F1,2
63H
26L
FZ
CZ1,2
30CZ,FZ
SW1
C
C01,03,04,11,
13,14,16,21
CR1,2
Name
Compressor motor
Fan motor (indoor)(*2)
Fan motor (outdoor)(*2)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat (compressor)
Over current relay (compressor)
Over current relay(fanI/D,O/D)
High-pressure switch
Thermostat (compressor)
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Switch (Fan Hi-Low)
Run capacitor
Connector
Surge killer
Controller connection.
Symbol
No.
TB4
1
2
3
4
Function
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
PAC-204RC
terminal no.
24VAC(L)
COMP1
FAN HI
24VAC (N)
BLUE
GRAY
14
FZ
CZ1
N
4
4
GRAY
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
Please remove the jumper wire ((*1) Mark) in the left diagram if
you use the switch <SW1> at local.
If the switch <SW1> is not used, the fan motor (indoor) drives at
high speed.
5. In case of power supply 220V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
6. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C>, <51F1,2> are installed.
Therefore, do not change factory set value of over current relays.
2. This motor (*2) includes auto reset type internal thermostat.
- 50 -
PE-8,10MYC-EU/PU-8,10MYC1-EU (STANDARD)
TB1
OUTDOOR
RED
L1
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
RED
L3
N
52C
WHITE
BLACK
BLACK
F3(3.15A) L1
BLUE
WHITE
BLACK
51F2
17 VIOLET
CIRCUIT BREAKER
(FIELD SUPPLY)
52C
TB5
18
16 VIOLET C14
15
1
2
19
C13
22
VIOLET
CZ2
30
CZ
3
21
TB6
30
CZ
RED
L2
L3
WHITE
51F1
C01RED
1
2
3
BLACK
RED
WHITE
BLACK
MF3
(*1)
14
CR2
52F
L1
RED
BLUE
TB2
INDOOR
MF2
(*1)
VIOLET 52C
N
N
BLACK
GRAY
14
20
CH
WHITE
CZ2
51C
1
RED
1
2
3
C21
GRAY
15
63H
C11
1
2
3
49C
PU- 8MYC1-EU···50A
PU-10MYC1-EU···60A
POWER SUPPLY
380~415VAC
3N~PE
50Hz
MC
51F2
RED
RED
PE
51C
RED
WHITE
F1 (3.15A)
L1
WHITE
C02
RED
MF1
BLUE
WHITE 1
BLUE
2
3
RED
N
TB4
GRAY
PE
C01
1
4
49F
C03
20
17
FZ
3
3
30FZ
Controller connection.
Symbol No. Function
TB4
1
2
3
4
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
3
2
CZ2
GRAY
PAC-204RC
terminal no.
24VAC(L)
COMP1
FAN HI
24VAC (N)
GRAY
3
14
52F
BLUE
GRAY
14
FZ
CZ1
Symbol
Name
Compressor motor
MC
MF1
Fan motor (indoor)
MF2,3
Fan motor (outdoor)(*1)
52C
Contactor (compressor)
52F
Contactor (fan I/D)
TB1~6
Terminal block
CH
Crankcase heater
F1~3
Fuse (3.15A)
Tr
Transformer
49F
Internal thermostat(indoor fan)
49C
Internal thermostat(compressor)
Over current relay(compressor)
51C
Over current relay(fanI/D,O/D)
51F1,2
High-pressure switch
63H
26L
Thermostat(freeze pretection)
FZ
Auxiliary relay (fan)
Auxiliary relay (compressor)
CZ1,2
Auxiliary relay (check)
30CZ,FZ
C01~04,11,
Connector
13,14,16,21
Surge killer
CR1,2
3
15
OUTDOOR
30
FZ
N
15
TB3
15
2
BLUE
1
26L
3
CR1
PINK
C16
GRAY
PINK
TB4
19
18
PAC-204RC
AC
24V
Tr
5
CZ1
C03 C04
1
SILVER 1
FAN HI
RED
8
24VAC(L)
51F1
PINK
COMP1
16
52F
1
1
F2 (3.15A)
24VAC(N)
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-8,10MYC-EU···15A
NOTE 4
C03
4
4
C01
1
2
3
GRAY
Attach the accessory
Remove
C02
1
2
3
MF1
1
2
3
This circuit diagram shows connections.
(If the external static pressure is less
than 30 pa, change to connections.)
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays<51C>, <51F1,2> are installed.
Therefore, do not change factory set value of over current
relays.
2. This motor (*1) includes auto reset type internal thermostat.
- 51 -
PE-15MYC1-EU/PU-15MYC1-EU (STANDARD)
TB1
OUTDOOR
L2
L3
CIRCUIT BREAKER
(FIELD SUPPLY)
PU-15MYC1-EU···100A
N
52C1
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
RED
WHITE
WHITE
52C2
RED
51C2
RED
52F2
RED
51F2
WHITE
BLACK
BLACK
BLACK
MC2
L1
RED
51
F2
18
52
C1
52
C2
VIOLET
49C1
19
VIOLET
ORANGE
C14
17
16
ORANGE
C24 1
CH1
2
20
1
1
CH2
25
51C1
23
26
VIOLET
21
30
CZ2-1
CZ1
3
3
22
TB5
N
N
WHITE
BLUE
51F1
MF1
BLACK
F1
(3.15A) RED
PE
L1
F2
(3.15A)
NOTE 4
C03
RED
1
C03
SILVER
C16
AC
24V
FZ
30
FZ
3
19
PAC-204RC
11
2
TB3
2
52
F1
GRAY3
CZ
1-1
BLUE N
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Contactor (fan O/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
Thermostat(freeze protection)
Auxiliary relay (fan)
Auxiliary relay (fan)
Auxiliary relay
Auxiliary relay (check)
Connector
Surge killer
Timer (2sec.)
Controller connection.
Symbol
No.
TB3
2,3
1
4
5
Function
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
PAC-204RC
terminal no.
24VAC(L)
2:COMP1
3:COMP2
FAN HI
24VAC (N)
C26
1
26L2
3
3
12
TB3
3
4
GRAY
11
12
11
12
OUTDOOR
CZ
1-2
FZ
CZ
2-2
13
5
GRAY
Note: 1.
2.
3.
4.
CZ
2-1
GRAY
4
5
Symbol
MC1,2
MF1
MF2
52C1,2
52F1
52F2
TB1~5
CH1,2
F1~3
Tr
49C1,2
51C1,2
51F1
51F2
63H1,2
26L1,2
FZ
30FZ
CZ1-1,2/2-1,2
30CZ1,2
C03,04,11,13,
14,16,23,24,26
CR1~3
2
1
26L1
TB4
CR1
PINK
30
FZ
3
CZ
1-2
GRAY GRAY
17
16
18
3
20
PINK
CZ
1-1
1
Tr
C03
6
TB3
C04
1
51F1
PINK
52F1
1
1
GRAY
FAN HI
BLUE
24VAC(L)
N
13
CR3
COMP2
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-15MYC1-EU···30A
RED
L2
L3
GRAY
52
F2
2
N
52F1
L1
29
ORANGE
CZ2-2
52
ORANGE C2
COMP1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
13
30
CZ2
BLUE
TB2
PINK
2
CZ
2-2
CZ
2-1
ORANGE
51C2
27
24VAC(N)
INDOOR
11 12 12
GRAY
GRAY
28
30
CZ2
30
CZ1
11
30
2
CR2
52
VIOLET C1
52
C2
TB4
63H2
63H1
C23
C13
52
C1
49C2
24
VIOLET
1
GRAY
13
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C1,2>, <51F1,2> are installed.
Therefore, do not change factory set value of over current
relays.
2. This timer <2> installed because the power supply breaker
may operate if two compressors start at the same time.
3. Do not change factory set value of all timers.
4. This motor (*1) includes auto reset type internal thermostat.
- 52 -
C11RED
1 WHITE
2 BLACK
3
WHITE
WHITE
F3(3.15A)
MC1
BLACK
BLACK
BLACK
BLUE
PE
51C1
RED
WHITE
MF2
(*1)
PE-20MYC-EU/PU-20MYC1-EU (STANDARD)
OUTDOOR
TB1
L2
L3
N
RED
51C1
52C1
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
WHITE
51C2
52C2
RED
PE
CIRCUIT BREAKER
(FIELD SUPPLY)
PU-20MYC1-EU···125A
WHITE
BLACK
BLACK
F3 (3.15A)
52F2
L1
RED
24
52
C2
19
25
17
C14
C24
20
1
21
3
2
26
51C1
CR2
30
CZ1
52
VIOLET C1
22
30
CZ1
2
52
ORANGE C2
RED
L2
L3
WHITE
52
F2
2
N
GRAY
13
BLUE
51F1
L1
F2
(3.15A)
NOTE 4
C03
SILVER
1
1
AC
24V
18
C03
3
20
PINK
30
FZ
30
FZ
3
3
PAC-204RC
11
2
TB3
2
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Contactor (fan O/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
Thermostat(freeze protection)
Auxiliary relay (fan)
Auxiliary relay (fan)
Auxiliary relay
Auxiliary relay (check)
Connector
Surge killer
Timer (2sec.)
Controller connection.
Symbol No. Function
1
TB3
2,3
4
5
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
C26
1
26L2
3
3
12
TB3
11
3
GRAY3
CZ
1-1
GRAY
CZ
1-2
4
12
OUTDOOR
4
CZ
2-1
GRAY
5
GRAY
12
CZ
2-2
13
FZ
5
Symbol
MC1,2
MF1
MF2,3
52C1,2
52F1
52F2
TB1~5
CH1,2
F1~3
Tr
49C1,2
51C1,2
51F1
51F2,3
63H1,2
26L1,2
FZ
30FZ
CZ1-1,2/2-1,2
30CZ1,2
C03,04,11,13,14,
16,21,23,24,26
CR1~3
2
1
26L1
11
52
F1
BLUE N
CZ
1-2
TB4
CR1
PINK
16
C16
Tr
PINK
19
CZ
1-1
GRAY GRAY
17
C03 C04
51F1
FZ
6
TB3
FAN HI
RED
1
52F1
1
1
GRAY
24VAC(L)
PE
CZ
2-2
MF1
F1
(3.15A) RED
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-20MYC-EU···30A
12
13
BLACK
BLUE
11
CZ
2-1
30
CR3
52F1
L1
N
1 WHITE
2 BLACK
3
GRAY GRAY
12
11
ORANGE
51C2
CZ
2-2
30
CZ2
COMP2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
1 WHITE
2 BLACK
3
C21RED
BLACK
29
30
CZ2
N
BLUE
2
28
TB2
INDOOR
C11RED
WHITE
1
COMP1
N
23
27
VIOLET
CZ2-1
3
51F3
MC2
63H2
63H1
CH2
CH1
1
PINK
TB4
C23
1
52
C2
RED
31
24VAC(N)
C13
52
C1
ORANGE
BLACK
49C2
49C1
52
C1
ORANGE
WHITE
51
F3
VIOLET
51F2
RED
RED
51
F2
16
VIOLET
RED
WHITE
18
MC1
BLACK
BLACK
BLACK
BLUE
TB5
RED
WHITE
WHITE
GRAY
13
Note:1. The dotted lines show field wiring.
2. The figure in the parenthesis show field supply parts.
3. Color of earth wire is yellow and green twisting.
4. In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C1,2>,<51F1,2> are installed.
Therefore, do not change factory set value of over current
relays.
2. This timer <2> installed because the power supply breaker
may operate if two compressors start at the same time.
3. Do not change factory set value of all timers.
4. This motor (*1) includes auto reset type internal thermostat.
PAC-204RC
terminal no.
24VAC(L)
2:COMP1
3:COMP2
FAN HI
24VAC (N)
- 53 -
MF2
(*1)
MF3
(*1)
PE-7MYC-EU / PU-7MYC1-EU
(SPECIAL ORDER : LOW AMBIENT COOLING)
OUTDOOR
TB1
L2
RED
F3(3.15A)
BLUE
WHITE
BLACK
BLACK
CIRCUIT BREAKER
(FIELD SUPPLY)
PU-7MYC1-EU···50A
52C
C11 1
WHITE
2
BLACK
3
51F2
17
MC
51F2
RED
L1
RED
PE
51C
RED
WHITE
L3
N
52C
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
LOW AMBIENT
COOLING PARTS
L1 U
C11
L2 V
L3 W
C21
VIOLET
TH
49C
18
C14
TB5
1
16 VIOLET
15
RED
1
2
3
RED
WHITE
BLACK
BLACK
GRAY
2
19
CZ2
C13
51C
1
22
VIOLET
CZ2
CH
14
20
3
30
CZ
21
GRAY
14
CR2
VIOLET 52C
30
CZ
TB6
N
N
(*1) JUMPER
INDOOR
TB2
L
POWER SUPPLY
220~240VAC
~PE
50Hz
TB4
51F1
52F
RED
L TB4
Hi
C01 RED
6
6
5
BROWN
2
Low
RED
F1 (3.15A)
L
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-7MYC-EU···15A
RED
NOTE 5
C03
C03
C04
1
TB4
GRAY
1
19
PINK
GRAY
1
26L
15
3
15
TB3
15
C03
3
3
OUTDOOR
3
TB4
30FZ
18
16
C16
COMP1
FZ
8
CZ1
24VAC(N)
AC
24V
Tr
52F
21
PAC-204RC
1
RED SILVER
PINK
4
1
1
C
PINK
F2
(3.15A)
51F1
17
BLUE
FAN HI
PE
7
SW2(FIELD SUPPLY)
BLUE
C01 PINK 20
MF1 5
6
24VAC(L)
N
(*2)
1
7
CZ2
3
2
CR1
2
PINK
GRAY
14
GRAY
3
52F
30
FZ
BLUE
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49C
51C
51F1,2
63H
26L
FZ
CZ1,2
30CZ,FZ
SW1
C
C01,03,04,11,
13,14,16,21
CR1,2
Name
Compressor motor
Fan motor (indoor)(*2)
Fan motor (outdoor)(*2)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat (compressor)
Over current relay (compressor)
Over current relay(fanI/D,O/D)
High-pressure switch
Thermostat (compressor)
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Switch (Fan Hi-Low)
Run capacitor
Connector
Surge killer
Controller connection.
Symbol
No.
TB4
1
2
3
4
Function
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
PAC-204RC
terminal no.
24VAC(L)
COMP1
FAN HI
24VAC (N)
BLUE
GRAY
14
FZ
CZ1
N
4
4
GRAY
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
Please remove the jumper wire ((*1) Mark) in the left diagram if
you use the switch <SW1> at local.
If the switch <SW1> is not used, the fan motor (indoor) drives at
high speed.
5. In case of power supply 220V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
6. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C>, <51F1,2> are installed.
Therefore, do not change factory set value of over current relays.
2. This motor (*2) includes auto reset type internal thermostat.
- 54 -
MF2
(*2)
WHITE
C21
15
63H
1
2
3
MF3
(*2)
PE-8,10MYC-EU / PU-8,10MYC1-EU
(SPECIAL ORDER : LOW AMBIENT COOLING)
TB1
OUTDOOR
RED
L1
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
RED
L3
N
52C
WHITE
BLACK
BLACK
F3(3.15A) L1
BLUE
51F2
CIRCUIT BREAKER
(FIELD SUPPLY)
WHITE
2
BLACK
3
52C
L1 U
LOW AMBIENT
COOLING PARTS
L2 V
L3 W
TH
TB5
18
16 VIOLET C14
15
1
19
C13
22
VIOLET
CZ2
30
CZ
3
21
TB6
30
CZ
51F1
52F
RED
L2
L3
WHITE
C01RED
1
2
3
BLACK
RED
WHITE
BLACK
BLUE
TB2
L1
RED
14
CR2
F1 (3.15A)
L1
WHITE
C02
RED
MF1
BLUE
WHITE 1
BLUE
2
3
RED
N
TB4
GRAY
PE
C01
1
4
49F
C03
20
17
FZ
3
3
30FZ
Controller connection.
Symbol No. Function
TB4
1
2
3
4
Power (Active)
Cooling operation
Fan operation
Power (Neutral)
3
2
CZ2
GRAY
PAC-204RC
terminal no.
24VAC(L)
COMP1
FAN HI
24VAC (N)
GRAY
3
14
52F
BLUE
GRAY
14
FZ
CZ1
Symbol
Name
Compressor motor
MC
MF1
Fan motor (indoor)
MF2,3
Fan motor (outdoor)(*1)
52C
Contactor (compressor)
52F
Contactor (fan I/D)
TB1~6
Terminal block
CH
Crankcase heater
F1~3
Fuse (3.15A)
Tr
Transformer
49F
Internal thermostat(indoor fan)
49C
Internal thermostat(compressor)
Over current relay(compressor)
51C
Over current relay(fanI/D,O/D)
51F1,2
High-pressure switch
63H
26L
Thermostat(freeze pretection)
FZ
Auxiliary relay (fan)
Auxiliary relay (compressor)
CZ1,2
Auxiliary relay (check)
30CZ,FZ
C01~04,11,
13,14,16,21 Connector
Surge killer
CR1,2
3
15
OUTDOOR
2
N
15
TB3
15
30
FZ
BLUE
1
26L
3
CR1
PINK
C16
GRAY
PINK
TB4
19
18
PAC-204RC
AC
24V
Tr
5
CZ1
C03 C04
1
SILVER 1
FAN HI
RED
8
24VAC(L)
51F1
PINK
COMP1
16
52F
1
1
F2 (3.15A)
24VAC(N)
CIRCUIT BREAKER
(FIELD SUPPLY)
PE-8,10MYC-EU···15A
NOTE 4
C03
4
4
C01
1
2
3
GRAY
Attach the accessory
Remove
C02
1
2
3
MF1
1
2
3
This circuit diagram shows connections.
(If the external static pressure is less
than 30 pa, change to connections.)
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays<51C>, <51F1,2> are installed.
Therefore, do not change factory set value of over current
relays.
2. This motor (*1) includes auto reset type internal thermostat.
- 55 -
MF2
(*1)
VIOLET 52C
N
N
BLACK
GRAY
14
20
CH
WHITE
CZ2
51C
1
RED
1
2
3
C21
GRAY
15
2
C11
1
2
3
49C
63H
INDOOR
C11 1
17 VIOLET
PU- 8MYC1-EU···50A
PU-10MYC1-EU···60A
POWER SUPPLY
380~415VAC
3N~PE
50Hz
MC
51F2
RED
RED
PE
51C
RED
WHITE
MF3
(*1)
PEH-5MYA-EU/PUH-5MYE1-EU (STANDARD)
TB1
OUTDOOR
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
RED
51C
RED
WHITE
WHITE
BLACK
L1
RED
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-5MYE1-EU···50A
(*1)
HZ2
51F2
17
22
FC
TB6
VIOLET
C14
52C
1C11RED
2
WHITE
MF2
3
BLACK
X1
WHITE
F3(3.15A)
PE
(*1)
51F2
RED
BLUE
MC
BLACK
BLACK
L3
N
52C
RED
L1
1
BROWN
16
T1
X1
X2
X1
28
63H1
24
23
1
C18
25
18
VIOLET
1
15
19
21
VIOLET
CZ2
BROWN
20
C15
CR2
21
S4
T1
VIOLET 52C
TB6 N
TB2
WHITE
RED
F1(3.15A)
L1
N
X WHITE
U
WHITE V
Y BLUE
MF1
Z RED
W
BLUE
C02
2
3
1
RED
PE
16
C01
TB4 1
GRAY
51F1
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-5MYA-EU···15A
14
T2
C01 RED
1
2
3
BLACK
BLUE
X1
NOTE 4
C03
PINK
4
RED
1
F2
(3.15A)
C03 C04
SILVER 1
1
52F
1
24VAC(L)
N
GRAY
BROWN
BLUE
51F1
52F
RED
L2
L3
X2
3
N
BLUE
L1
14
27
1
30
CZ
INDOOR
13
HZ2
CZ2
T2
30
CZ
3
TB5
26D
BROWN
26
CH
POWER SUPPLY
380~415VAC
3N~PE
50Hz
13
GRAY
GRAY
2
51C
C13
15
63H2
2
GRAY 6
CZ1
PAC-204RC
GRAY
TB3
HZ1
GRAY
15
13
15
13
15
13
PINK
30FZ
OUTDOOR
CZ2
TB4
C03
18
3
52F
FAN HI
PINK
AC
24V
Tr
19
FZ
4WV
5
COMP1
17
24VAC(N)
49F
3
3
CR1
GRAY
2
3
GRAY
3
2
CZ1 HZ1
4
GRAY
4
14
FZ
30
FZ
14
BLUE
Symbol
MC
MF1
MF2
52C
52F
TB1~6
CH
F1~3
Tr
49F
51C
51F1
51F2
63H1
63H2
26D
Name
Compressor motor(*1)
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(fan I/D)
Over current relay(compressor)
Over current relay(fan I/D)
Over current relay(fan O/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat (defrost)
HZ2
N
Symbol
21S4
FZ
CZ1,2
HZ1,2
30CZ,30FZ
X1
X2
C01~04,11
13~15,18
T1
T2
CR1,2
GRAY
5
5
Name
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Connector
Attach the accessory
Remove
C02
C01
1
2
3
RED U
X WHITE
WHITE V MF1 Y BLUE 2
Z RED
3
BLUE W
1
2
3
1
This circuit diagram shows connections.
(If the external static pressure is less
than 30 pa, change to connections.)
Note: 1. The dotted lines show field wiring.
2. The figure in the parenthesis show field supply parts.
3. Color of earth wire is yellow and green twisting.
4. In case of power supply 380V AC model Tr wiring.
Timer
Timer
Surge killer
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
Controller connection.
PAC-204RC
terminal no.
Power (Active)
24VAC(L)
Cooling or Heating operation COMP1
Revercing Valve
4WV
for Heating operation
FAN HI
Fan operation
24VAC(N)
Power (Neutral)
C03 3
Symbol No. Function
TB4
1
2
3
4
5
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current,over current relays<51C>,<51F1,2> are installed.
Therefore,do not change factory set value of over current
relays.
2. Do not change factory set value of timer.
3. This motor (*1) includes auto reset type internal thermostat.
- 56 -
PEH-7MYA-EU/ PUH-7MYC2-EU (STANDARD)
OUTDOOR
TB1
L2
RED
F3(3.15A)
BLUE
WHITE
BLACK
BLACK
L1
RED
WHITE
RED
RED
PE
HZ2
51F2
17
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-7MYC2-EU···50A
16
C13
X1
X2
1
X1 GRAY
T1
29
25
24
C18
26
1
13
GRAY
15
13
30
CZ
VIOLET 52C
WHITE
MF3
BLACK
(*2)
C21
HZ2
26D
GRAY
14
T2
28
3
X2
N
BLUE
(*2)
RED
14
1
21
S4
T1
CR2
1
2
3
27
C15
VIOLET
30
CZ
N
BROWN
BROWN
22
CZ2
20
21
1C11RED
2
WHITE
MF2
3
BLACK
2
BROWN
51C
3
15
63H2 CZ2
2
1
CH
TB6
TB5
63H1
VIOLET
19
X1
BLACK
TB6 FC BROWN
18
C14
MC
51F2
23
VIOLET
49C
52C
51C
RED
WHITE
L3
N
52C
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
X1
T2
BLUE
N
(*1) JUMPER
INDOOR
TB2
L
POWER SUPPLY
220~240VAC
~PE
50Hz
TB4
51F1
52F
RED
L
TB4
Hi
7
6
8
F1 (3.15A)
BROWN
BLUE
4
TB4 1
GRAY
RED
C01 PINK 20
MF1 5
6
52F
C
PINK
6
GRAY
1
C03 C04
1
SILVER 1
PINK
17
AC
24V
Tr
19 PINK
PAC-204RC
16
C16
15
TB3
FZ
TB4
C03
30FZ
3
PINK
3
3
2
GRAY
3
GRAY
2
CR1
52F
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49C
51C
51F1
51F2
63H1
63H2
26L
26D
Name
Compressor motor
Fan motor (indoor)(*2)
Fan motor (outdoor)(*2)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
Thermostat (defrost)
1
3
15
13
15
13
OUTDOOR
CZ2
3
HZ2
4
14
FZ
14
N
BLUE
HZ1
GRAY
13
4
GRAY
CZ1 HZ1
30
FZ
CZ1
GRAY
26L HZ1
FAN HI
RED
51F1
F2
(3.15A)
24VAC(L)
NOTE 5
C03
4WV
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-7MYA-EU···15A
18
21
1
L
COMP1
RED
24VAC(N)
PE
8
SW1(FIELD SUPPLY)
BLUE
(*2)
1
2
Low
N
C01RED
7
Symbol
21S4
FZ
CZ1,2
HZ1,2
30CZ,30FZ
X1
X2
<SW1>
C01,03,04,11
13~16,18,21
T1
T2
CR1,2
C
BLUE
GRAY
Name
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Switch (Fan Hi-Low)
Connector
Timer
Timer
Surge killer
Run capacitor
5
5
GRAY
Note:1. The dotted lines show field wiring.
2. The figure in the parenthesis show field supply
parts.
3. Color of earth wire is yellow and green twisting.
4. Please remove the jumper wire [(*1) Mark] in the left
diagram if you use the switch <SW1> at local.
If the switch <SW1> is not used, the fan motor
(indoor) drives at higi speed.
5. In case of power supply 220V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
6. Specification subject to change without notice.
Controller connection.
Symbol No. Function
TB4
1
2
3
4
5
Power (Active)
Cooling or Heating operation
Revercing Valve
for Heating operation
Fan operation
Power (Neutral)
Caution,
1. To protect each fan motor and compressor from
abnormal current, over current
relays<51C>,<51F1,2> are installed. Therefore, do
not change factory set value of over current relays.
2. Do not change factory set value of timer.
3. This motor (*2) includes auto reset type internal
thermostat.
PAC-204RC
terminal no.
24VAC(L)
COMP1
4WV
FAN HI
24VAC(N)
- 57 -
PEH-8,10MYA-EU/PUH-8,10MYC2-EU (STANDARD)
PEH-8,10MYA-EU/PUH-8,10MYE1-EU
OUTDOOR
L1
TB1
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
N
51C
RED
WHITE
WHITE
BLUE
PE
1C11RED
2
WHITE
MF2
3
BLACK
X1
BLACK
L1
RED
(*1)
1C21 RED
2
WHITE
MF3
3
BLACK
HZ2
51F2
23
17 VIOLET
BROWN
FC
TB6
(*1)
49C
52C
18
X1
X2
C14
16
51F2
RED
WHITE
F3(3.15A)
PUH- 8MYC2-EU···50A
PUH-10MYC2-EU···60A
PUH- 8MYE1-EU···50A
PUH-10MYE1-EU···60A
MC
BLACK
BLACK
L3
CIRCUIT BREAKER
(FIELD SUPPLY)
52C
RED
RED
1
29
C18
26
25
24
63H1
VIOLET
X1
T1
TB5
1
15
63H2
15
2 GRAY GRAY
2
19
C13
1
51C
26D
22
VIOLET
CZ2
CH
BROWN
3
C15
CR2
VIOLET 52C
21
S4
T1
TB2
WHITE
C02
X WHITE
U
WHITE V
Y BLUE 2
MF1
3
Z
W
RED
BLUE
C01 RED
1
2
3
BLACK
RED
N
N
BLUE
F1 (3.15A)
1
L1
RED
TB4 1
GRAY
51F1
SILVER
24VAC(L)
RED
C03
1
C04
1
1
4
49F
AC
24V
Tr
5
FZ
PINK
C03
3
3
TB4
GRAY
N
Symbol
26D
21S4
FZ
CZ1,2
HZ1,2
30CZ,30FZ
X1
X2
C01~04,11,
13~16,18,21
T1
T2
CR1,2
BLUE
GRAY
Name
Thermostat (defrost)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Connector
Timer
Timer
Surge killer
4
5
15
2
3
HZ1
GRAY
13
1
GRAY
4
CZ2
FZ
13
13
HZ2
OUTDOOR
14
5
5
C01
1
2
3
3
15
15
4
GRAY
3
2
GRAY
14
Attach the accessory
Remove
C02
1
2
3
1
2
3
MF1
This circuit diagram shows connections.
(If the external static pressure is less
than 30 pa, change to connections.)
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 3
PAC-204RC
terminal no.
Power (Active)
24VAC(L)
Cooling or Heating operation COMP1
Revercing Valve
4WV
for Heating operation
FAN HI
Fan operation
24VAC(N)
Power (Neutral)
Symbol No. Function
TB4
CZ1
GRAY
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
Controller connection.
1
2
3
C16
CZ1 HZ1
52F
30
FZ
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(indoor fan)
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fan I/D)
Over current relay(fan O/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
18
PAC-204RC
26L HZ1
CR1
PINK
19
GRAY
TB3
3
30FZ
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49F
49C
51C
51F1
51F2
63H1
63H2
26L
6
20
17
BLUE
52F
1
4WV
NOTE 4
C03
PINK
16
C01
F2
(3.15A)
FAN HI
PE
COMP1
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-8,10MYA-EU···15A
RED
L2
L3
GRAY
14
T2
X1
51F1
52F
L1
BROWN
24VAC(N)
INDOOR
X2
3
N
BLUE
28
1
30
CZ
POWER SUPPLY
380~415VAC
3N~PE
50Hz
14
T2
30
CZ
21
N
CZ2 HZ2
27
BROWN
20
TB6
13
13
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from
abnormal current, over current relays<51C>,<51F1,2>
are installed. Therefore, do not change factory set
value of over current relays.
2. Do not change factory set value of timer.
3. This motor (*1) includes auto reset type internal
thermostat.
- 58 -
PEH-15,20MYA-EU/PUH-15,20MYC2-EU (STANDARD)
OUTDOOR
L1
TB1
WHITE
BLACK
BLACK
BLUE
N
WHITE
BLACK
52C2
WHITE
F3(3.15A)
RED
L1
HZ2
52C2
C14
16
VIOLET ORANGE
C13
19
C23
1
CH1
23
1
24
VIOLET
C24
1
2
25
22
VIOLET
20
3
30
CZ1
3
T2
PINK
1
28
ORANGE
2
C28
1
2
30
CZ2
CZ
2-2 52
ORANGE
41
3
N
13
CZ
2-2
HZ2
GRAY
T4
42
3
T3
X1
13
GRAY
12
14
BROWN
N
12
GRAY
11
CZ
2-1
X4
T2
21
S4-2
T3
S4-1
2
C2
1
11
GRAY
26
D2
40
C25
X3
T1
(*1)
TB4
63H
2-2
26
D1
35
C15 1
29
CR3
21
1C21 RED
2
WHITE
MF3
3
BLACK
X2
X2
44
PINK
39
63H
2-1
51C2
27
37
PINK
X1
43
BROWN
34 C18
PINK
14
T4
X2
BLUE
N
51F1
52F
WHITE
MF1
BLACK
L1
GRAY
RED
NOTE 4
C03
C03
RED
1
SILVER
51F1
F2
(3.15A)
3
FZ
30
FZ
18
PINK
3
3
Symbol
MC1,2
MF1
MF2,3
52C1,2
52F
TB1~5
CH1,2
F1~3
Tr
49C1,2
51C1,2
51F1
51F2,3
63H1-1,1-2
63H2-1,2-2
26L1,2
26D1,2
21S4-1,2
FZ
30FZ
CZ1-1,2/2-1,2
HZ1-1,2/2
30CZ1,2
X1,2
X3,4
C03,04,11,13~16,
18,21,23~26,28
T1,2
T3,4
2
CR1~3
GRAY
CZ
1-1
GRAY
C16
CZ
1-2
16
GRAY
13
HZ
1-1
GRAY
C26 1
1
HZ
HZ
26L1 1-1
26L2 1-2
3
3
11
12
TB3
11
12
13
11
12
13
OUTDOOR
19
PINK
CR1
TB3
3
2
5
4
CZ
2-2
CZ
2-1
GRAY GRAY GRAY
3
4
5
GRAY
2
HZ2
52F
CZ
1-1
30
FZ
BLUE
7
15
1
AC
24V
Tr
C03
52F
1
TB3
C04
1
PINK
17
1
FAN HI
PE
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-15,20MYA-EU···30A
4WV
F1
(3.15A)
COMP2
BLUE
20VAC(L)
N
C1
38
51F3
WHITE
BLACK
X3
X2
2
2
30
CZ2
RED
RED
L2
L3
32
X4
BROWN 36
T1
COMP1
L1
33
BROWN
20VAC(N)
INDOOR
TB2
31
1
CR2
CZ
2-1 52
VIOLET
30
CZ1
BLUE
X4
X1
ORANGE
26
21
N
X3
63H1-2
63H1-1
51C1
CH2
51F3
49C2
49C1
18
15
51F2
MC2
BLACK
30 TB5 FC
BROWN
RED
17
52C1
(*1)
51C2
RED
RED
1 C11RED
2
WHITE
MF2
3
BLACK
X1
RED
WHITE
BLACK
RED
PE
POWER SUPPLY
380~415VAC
3N~PE
50Hz
MC1
BLACK
51F2
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-15MYC2-EU···100A
PUH-20MYC2-EU···125A
TB5
51C1
RED
WHITE
WHITE
L3
52C1
RED
RED
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
N
GRAY
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
Thermostat (defrost)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (fan)
Auxiliary relay
Auxiliary relay (heater)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Connector
Timer
Timer
Timer (2sec.)
Surge killer
CZ
1-2
HZ1
FZ
14
6
6
Note:1.
2.
3.
4.
GRAY
14
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C1,2>, <51F1,2,3> are
installed. Therefore, do not change factory set value of over
current relays.
2. Timers<T1,2> are installed for defrost control.
3. This timer <2> installed because the power supply breaker
may operate two compressors start at the same time.
4. Do not change factory set value of all timers.
5. This motor (*1) includes auto reset type internal thermostat.
Controller connection.
PAC-204RC
terminal no.
Power (Active)
24VAC(L)
Cooling or Heating operation COMP1
Cooling or Heating operation COMP2
Revercing Valve
4WV
for Heating operation
Fan operation
FAN HI
Power (Neutral)
24VAC(N)
Symbol No. Function
TB3
1
2
3
4
5
6
- 59 -
PEH-7MYA-EU / PUH-7MYC2-EU
(SPECIAL ORDER : LOW AMBIENT COOLING)
OUTDOOR
TB1
L2
RED
F3(3.15A)
BLUE
L1
WHITE
BLACK
BLACK
HZ2
51F2
17
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-7MYC2-EU···50A
TB6 FC BROWN
18
16
C13
X1
X2
1
25
C18
26
BROWN
BROWN
22
3
VIOLET 52C
2
3
L3 W
C21 1
2
3
TH
FC
RED
WHITE
BLACK
RED
WHITE
BLACK
C21
N
FULL LOAD INPUT
(ONLY HEAT PUMP)
HZ2
14
26D
GRAY
T2
28
3
X2
N
BLUE
C11 1
L2 V
14
21
S4
T1
CR2
L1 U
2
1
20
30
CZ
LOW AMBIENT
COOLING PARTS
27
C15
VIOLET
30
CZ
N
13
1
BROWN
CZ2
21
13
GRAY
15
63H2 CZ2
2
51C
3
15
X1 GRAY
T1
29
24
1
CH
TB6
TB5
63H1
VIOLET
19
2
23
VIOLET
C14
X1 C11 1
BLACK
49C
52C
MC
51F2
RED
WHITE
RED
RED
PE
51C
RED
WHITE
L3
N
52C
RED
L1
POWER SUPPLY
380~415VAC
3N~PE
50Hz
X1
T2
BLUE
N
(*1) JUMPER
INDOOR
TB2
L
POWER SUPPLY
220~240VAC
~PE
50Hz
RED
TB4
51F1
52F
L
TB4
Hi
6
F1 (3.15A)
RED
(*2)
1
BROWN
2
BLUE
4
TB4 1
GRAY
C01 PINK 20
MF1 5
6
52F
C
PINK
6
GRAY
RED
51F1
1
F2
(3.15A)
C03 C04
1
SILVER 1
PINK
17
AC
24V
Tr
19 PINK
PAC-204RC
16
C16
15
TB3
FZ
30FZ
3
PINK
Name
Compressor motor
Fan motor (indoor)(*2)
Fan motor (outdoor)(*2)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
Thermostat (defrost)
3
3
Symbol
21S4
FZ
CZ1,2
HZ1,2
30CZ,30FZ
X1
X2
<SW1>
C01,03,04,11
13~16,18,21
T1
T2
CR1,2
C
TB4
4
5
Power (Active)
Cooling or Heating operation
Revercing Valve
for Heating operation
Fan operation
Power (Neutral)
3
15
13
13
OUTDOOR
4
GRAY
3
CZ1 HZ1
BLUE
GRAY
Name
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Switch (Fan Hi-Low)
Connector
Timer
Timer
Surge killer
Run capacitor
CZ2
HZ2
4
14
FZ
5
5
GRAY
Note:1. The dotted lines show field wiring.
2. The figure in the parenthesis show field supply
parts.
3. Color of earth wire is yellow and green twisting.
4. Please remove the jumper wire [(*1) Mark] in the left
diagram if you use the switch <SW1> at local.
If the switch <SW1> is not used, the fan motor
(indoor) drives at higi speed.
5. In case of power supply 220V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
6. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from
abnormal current, over current
relays<51C>,<51F1,2> are installed. Therefore, do
not change factory set value of over current relays.
2. Do not change factory set value of timer.
3. This motor (*2) includes auto reset type internal
thermostat.
Controller connection.
1
2
3
1
14
N
Symbol No. Function
GRAY
2
CR1
3
2
GRAY
52F
30
FZ
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49C
51C
51F1
51F2
63H1
63H2
26L
26D
HZ1
GRAY
13
15
TB4
C03
BLUE
CZ1
GRAY
26L HZ1
FAN HI
NOTE 5
C03
24VAC(L)
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-7MYA-EU···15A
18
21
1
L
4WV
RED
COMP1
PE
8
Low 8
SW1(FIELD SUPPLY)
BLUE
24VAC(N)
N
C01RED
7
7
PAC-204RC
terminal no.
24VAC(L)
COMP1
4WV
FAN HI
24VAC(N)
- 60 -
MF2
(*2)
MF3
(*2)
PEH-8,10MYA-EU / PUH-8,10MYE1-EU
PEH-8,10MYA-EU / PUH-8,10MYC2-EU
(SPECIAL ORDER : LOW AMBIENT COOLING)
TB1
BLUE
RED
WHITE
F3(3.15A)
PE
PUH- 8MYC2-EU···50A
PUH-10MYC2-EU···60A
PUH- 8MYE1-EU···50A
PUH-10MYE1-EU···60A
FC
N
X1
24
51C
C15
CR2
VIOLET 52C
21
S4
T1
X2
3
N
BLUE
TB2
RED
F1 (3.15A)
C01 RED
X WHITE
U
WHITE V
Y BLUE
MF1
Z RED
BLUE W
C02
TB4 1
GRAY
F2
(3.15A)
NOTE 4
C03
RED
C01
C03
C04
1
SILVER 1
1
4
49F
AC
24V
Tr
5
2
3
1
FZ
PINK
PINK
C03
3
3
18
PAC-204RC
C16
TB4
GRAY
30
FZ
Symbol
26D
21S4
FZ
CZ1,2
HZ1,2
30CZ,30FZ
X1
X2
C01~04,11,
13~16,18,21
T1
T2
CR1,2
2
3
15
BLUE
GRAY
Name
Thermostat (defrost)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Connector
Timer
Timer
Surge killer
CZ1
HZ1
GRAY
GRAY
13
1
GRAY
4
CZ2
FZ
13
13
HZ2
OUTDOOR
14
5
5
C01
1
2
3
3
15
15
4
GRAY
3
2
CZ1 HZ1
52F
N
GRAY
26L HZ1
CR1
19
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(indoor fan)
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fan I/D)
Over current relay(fan O/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
6
TB3
3
30FZ
BLUE
52F
1
20
17
GRAY
14
Attach the accessory
Remove
C02
1
2
3
1
2
3
MF1
This circuit diagram shows connections.
(If the external static pressure is less
than 30 pa, change to connections.)
Note: 1.
2.
3.
4.
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
Controller connection.
C03 3
PAC-204RC
terminal no.
Power (Active)
24VAC(L)
Cooling or Heating operation COMP1
Revercing Valve
4WV
for Heating operation
FAN HI
Fan operation
24VAC(N)
Power (Neutral)
Symbol No. Function
4
5
GRAY
RED
PE
PINK
TB4
13
L1
16
1
2
3
MF3
(*1)
N
1
2
3
51F1
Symbol
MC
MF1
MF2,3
52C
52F
TB1~6
CH
F1~3
Tr
49F
49C
51C
51F1
51F2
63H1
63H2
26L
BLACK
14
T2
BLUE
51F1
52F
BROWN
X1
BLACK
N
WHITE
14
28
1
30
CZ
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-8,10MYA-EU···15A
RED
CZ2 HZ2
27
BROWN
T2
30
CZ
21
WHITE
MF2
(*1)
BROWN
3
RED
BLACK
26D
22
VIOLET
CZ2
20
L2
L3
WHITE
FULL LOAD INPUT
(ONLY HEAT PUMP)
TB5
15
63H2
2
1
L1
X1
1
RED
15
13
2 GRAY GRAY
CH
INDOOR
T1
C18
29
26
25
1
2
3
C21
1
2
3
TH
1
19
POWER SUPPLY
380~415VAC
3N~PE
50Hz
L3 W
BROWN
FC
TB6
63H1
C11
L2 V
3
X2
C14
VIOLET
N
L1 U
2
23
18
TB6
LOW AMBIENT
COOLING PARTS
49C
52C
C13
C11 1
HZ2
51F2
17 VIOLET
16
X1
BLACK
L1
RED
MC
BLACK
51F2
FAN HI
N
RED
WHITE
BLACK
L3
CIRCUIT BREAKER
(FIELD SUPPLY)
51C
WHITE
24VAC(L)
POWER SUPPLY
380~415VAC
3N~PE
50Hz
52C
RED
RED
4WV
L2
COMP1
L1
24VAC(N)
OUTDOOR
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from
abnormal current, over current relays<51C>,<51F1,2>
are installed. Therefore, do not change factory set
value of over current relays.
2. Do not change factory set value of timer.
3. This motor (*1) includes auto reset type internal
thermostat.
- 61 -
PEH-15,20MYA-EU / PUH-15,20MYC2-EU
(SPECIAL ORDER : LOW AMBIENT COOLING)
OUTDOOR
L1
TB1
WHITE
BLACK
BLACK
BLUE
N
WHITE
BLACK
52C2
RED
L1
HZ2
52C2
C14
VIOLET ORANGE
19
C23
C13
1
1
CH1
23
24
VIOLET
C24
1
2
25
22
VIOLET
20
TB2
28
30
CZ2
ORANGE
2
CZ
2-2 52
T2
C28
TH1
41
3
N
L3 W
GRAY
GRAY
11
12
13
CZ
2-1
CZ
2-2
TH2
FC
N
HZ2
GRAY
PINK
14
T4
X2
BLUE
N
51F1
52F
WHITE
MF1
BLACK
L1
GRAY
RED
NOTE 4
C03
C03
RED
1
SILVER
51F1
F2
(3.15A)
1
Tr
C03
3
FZ
30
FZ
18
3
3
GRAY
C16
TB3
Symbol
MC1,2
MF1
MF2,3
52C1,2
52F
TB1~5
CH1,2
F1~3
Tr
49C1,2
51C1,2
51F1
51F2,3
63H1-1,1-2
63H2-1,2-2
26L1,2
26D1,2
21S4-1,2
FZ
30FZ
CZ1-1,2/2-1,2
HZ1-1,2/2
30CZ1,2
X1,2
X3,4
C03,04,11,13~16,
18,21,23~26,28
T1,2
T3,4
2
CR1~3
3
2
GRAY
CZ
1-2
16
GRAY
13
HZ
1-1
GRAY
C26 1
1
HZ
HZ
26L1 1-1
26L2 1-2
3
3
11
12
TB3
4
5
11
12
11
12
3
4
CZ
2-2
CZ
2-1
GRAY GRAY GRAY
13
13
HZ2
5
52F
CZ
1-1
N
GRAY
CZ
1-1
15
2
PINK
7
OUTDOOR
19
PINK
CR1
30
FZ
BLUE
1
TB3
1
AC
24V
PINK
17
1
C04
FAN HI
PE
CIRCUIT BREAKER
(FIELD SUPPLY)
PEH-15,20MYA-EU···30A
52F
4WV
F1
(3.15A)
COMP2
BLUE
GRAY
CZ
1-2
6
Name
Compressor motor
Fan motor (indoor)
Fan motor (outdoor)(*1)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse (3.15A)
Transformer
Internal thermostat(compressor)
Over current relay(compressor)
Over current relay(fanI/D)
Over current relay(fanO/D)
High-pressure switch
High-pressure switch (defrost)
Thermostat(freeze protection)
Thermostat (defrost)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (fan)
Auxiliary relay
Auxiliary relay (heater)
Auxiliary relay (check)
Contactor (fan O/D)
Auxiliary relay (defrost)
Connector
Timer
Timer
Timer (2sec.)
Surge killer
HZ1
FZ
14
6
GRAY
Note:1.
2.
3.
4.
14
The dotted lines show field wiring.
The figure in the parenthesis show field supply parts.
Color of earth wire is yellow and green twisting.
In case of power supply 380V AC model Tr wiring.
C03 1 C03 1 C04
1
RED
SILVER
AC
24V
Tr
C03 3
3
3
5. Specification subject to change without notice.
Caution,
1. To protect each fan motor and compressor from abnormal
current, over current relays <51C1,2>, <51F1,2,3> are
installed. Therefore, do not change factory set value of over
current relays.
2. Timers<T1,2> are installed for defrost control.
3. This timer <2> installed because the power supply breaker
may operate two compressors start at the same time.
4. Do not change factory set value of all timers.
5. This motor (*1) includes auto reset type internal thermostat.
Controller connection.
PAC-204RC
terminal no.
Power (Active)
24VAC(L)
Cooling or Heating operation COMP1
Cooling or Heating operation COMP2
Revercing Valve
4WV
for Heating operation
Fan operation
FAN HI
Power (Neutral)
24VAC(N)
Symbol No. Function
TB3
1
2
3
4
5
6
- 62 -
1
2
3
RED
WHITE
BLACK
MF3
(*1)
FULL LOAD INPUT
(ONLY HEAT PUMP)
14
3
T3
X1
L2 V
13
GRAY
T4
42
BROWN
N
TB4
12
LOW AMBIENT
COOLING PARTS C21
L1 U
3
11
X4
T2
1
2
26
D2
40
1
21
S4-2
T3
2
N
X2
1
2
C25
X3
T1
S4-1
FC
MC2
51F3
63H
2-2
(*1)
FULL LOAD INPUT
(ONLY HEAT PUMP)
X2
44
PINK
39
PINK
1
26
D1
35
C15 1
29
CR3
21
C2
ORANGE
30
CZ2
37
PINK
2
51C2
27
38
63H
2-1
20VAC(L)
N
C1
VIOLET
RED
RED
L2
L3
2
2 WHITE
MF2
3 BLACK
L3 W
51C2
WHITE
BLACK
X3
X2
X1
BROWN
34 C18
BROWN
1
COMP1
L1
X4
BROWN 36
43
20VAC(N)
INDOOR
33
32
ORANGE
CR2
CZ
2-1 52
30
CZ1
BLUE
X4
X1
T1
26
30
CZ1
3
21
N
X3
31
63H1-2
63H1-1
51C1
CH2
3
51F3
49C2
49C1
18
16
51F2
C11 1 RED
L2 V
BLACK
30 TB5 FC
BROWN
RED
17
LOW AMBIENT
COOLING PARTS
L1 U
3
WHITE
F3(3.15A)
15
1
2
RED
RED
52C1
X1
RED
WHITE
BLACK
RED
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-15MYC2-EU···100A
PUH-20MYC2-EU···125A
POWER SUPPLY
380~415VAC
3N~PE
50Hz
MC1
BLACK
51F2
PE
TB5
51C1
RED
WHITE
WHITE
L3
52C1
RED
RED
L2
POWER SUPPLY
380~415VAC
3N~PE
50Hz
ELECTRICAL OPERATION FLOW CHARTS
PE-7,8,10MYC-EU
PEH-5MYA-EU, PEH-7,8,10MYA-EU
START
START
POWER ON
POWER ON
CH ON
CH ON
30FZ,30CZ ON (SELF HOLD)
30FZ,30CZ ON (SELF HOLD)
LCD controller
ON?
NO
YES
YES
FZ ON
FZ ON
52F ON
MF1 OPERATE
LCD controller
COMP ON?
52F ON
MF1 OPERATE
NO
YES
CZ1,2
NO
LCD controller
ON?
NO
COOL MODE?
HZ1,2 ON
21S4
YES
ON
NO
LCD controller
COMP ON?
52C
ON
MC
OPERATE
MF2, 3 OPERATE
NO
YES
CZ1
LCD controller
COMP ON?
ON
YES
CZ1,2
CH
OFF
SAFETY
DEVICE OFF?
YES
30CZ
52C
MC
MF1
MF2,3
CH
52C
ON
MC
OPERATE
MF2, 3 OPERATE
NO
OFF
OFF
STOP
Note
STOP
ON
CH
ON
ON
52C
ON
MC
OPERATE
MF2, 3 OPERATE
OFF
CH OFF
SAFETY
DEVICE OFF?
YES
30CZ
52C
MC
MF1
MF2,3
NO
PASS THE 30 MIN ?
(T1)
NO
YES
OFF
26D ON ?
Condensing
-4±1.5˚C
temp.
OFF
STOP
Note
STOP
NO
YES
T2 ON
X1 ON (SELF HOLD)
SERVICE CALL
CH
X2 ON
ON
21S4 OFF
T1 OFF
MF2, 3 STOP
SERVICE CALL
PASS THE 15 MIN ?
(T2)
Note.
1. When the fault of outdoor unit is
occurred, the fan(MF1) of indoor
unit continues to work.
But the unit doesn't work correctly
(not cooling and heating ).
Then, turn off the power supply
and check outdoor unit.
NO
YES
X1 OFF
T2 OFF
X2 OFF
21S4 T1 ON
MF2, 3 OPERATE
- 63 -
YES
26D OFF?
Condensing 26±1.5˚C
temp.
or
63H2 OFF?
High
pressure 2.16MPa
NO
PE-15MYC1-EU
PE-20MYC-EU
START
START
POWER ON
POWER ON
CH1,2 ON
CH1,2 ON
30FZ,30CZ1,2 ON (SELF HOLD)
30FZ,30CZ1,2 ON (SELF HOLD)
NO
LCD controller
ON?
YES
YES
FZ ON
FZ ON
52F1 ON
MF1 OPERATE
52F1 ON
MF1 OPERATE
NO
LCD controller
COMP ON?
NO
LCD controller
COMP ON?
YES
YES
CZ1-1,CZ2-1 ON
CZ1-1,CZ2-1 ON
52C1 ON
MC1 OPERATE
MF2 OPERATE
52C1 ON
MC1 OPERATE
MF2 OPERATE
CH 1
OFF
CH 1
CZ1-2,CZ2-2 ON
TIMER 2 ON
NO
PASS THE 3 MIN?
52C2 ON
MC2 OPERATE
CH2
OFF
CH2
No.2 SAFETY
DEVICE OFF?
YES
30CZ1 OFF
YES
30CZ2 OFF
CH1
NO
52C2 ON
MC2 OPERATE
MF3 OPERATE
No.1 SAFETY
DEVICE OFF?
52C1
MC1
MF2
OFF
CZ1-2,CZ2-2 ON
TIMER 2 ON
PASS THE 3 MIN?
NO
NO
LCD controller
ON?
52C2
MC2
MF2
OFF
STOP
STOP
CH2
ON
NO
OFF
STOP
STOP
NO
No.1 SAFETY
DEVICE OFF?
No.2 SAFETY
DEVICE OFF?
YES
30CZ1 OFF
YES
30CZ2 OFF
52C1
MC1
MF2,3
ON
CH1
SERVICE CALL
OFF
52C2
MC2
MF2,3
OFF
STOP
STOP
CH2
ON
SERVICE CALL
Note:
When the fault of outdoor unit is occurred, the fan(MF1) of indoor unit continues to work.
But the unit doesn’t work correctly (not cooling ).
Then, turn off the power supply and check outdoor unit.
When the fault of indoor unit is occurred, both indoor unit and outdoor unit is stop.
- 64 -
OFF
STOP
STOP
ON
NO
PEH-15,20MYA-EU
START
POWER ON
CH1,2 ON
30FZ,30CZ1,2 ON (SELF HOLD)
NO
LCD controller
ON?
YES
FZ ON
52F1 ON
MF1 OPERATE
NO
COOL MODE?
HZ1,2 ON
21S4-1,2 ON
T1,T2 ON
YES
NO
LCD controller
COMP ON?
YES
YES
CZ1-1,CZ2-1 ON
CZ1-1,CZ2-1 ON
52C1
MC1
MF2
52C1
MC1
MF2
CH 1
ON
OPERATE
OPERATE
CH 1
OFF
NO
PASS THE 3 MIN?
OFF
PASS THE 3 MIN?
YES
CH 2
ON
OPERATE
OPERATE
CZ1-2,CZ2-2 ON
TIMER 2 ON
CZ1-2,CZ2-2 ON
TIMER 2 ON
52C2
MC2
MF3
NO
LCD controller
COMP ON?
NO
PASS
THE 30 MIN ON?
(T1)
YES
ON
OPERATE
OPERATE
52C2
MC2
MF3
OFF
CH 2
ON
OPERATE
OPERATE
PASS
THE 30 MIN ON?
(T2)
NO
YES
NO
26D1 ON?
Condensing
-4±1.5˚C
temp.
OFF
YES
X4 ON?
No.1 SAFETY
DEVICE OFF?
No.2 SAFETY
DEVICE OFF?
YES
30CZ1 OFF
52C1
MC1
MF2
CH1
YES
30CZ2 OFF
OFF
STOP
STOP
52C2
MC2
MF3
ON
CH2
SERVICE CALL
OFF
STOP
STOP
ON
NO
NO
No.1 SAFETY
DEVICE OFF?
No.2 SAFETY
DEVICE OFF?
YES
30CZ1 OFF
52C1
MC1
MF2
CH1
NO
26D2 ON?
Condensing
-4±1.5˚C
temp.
YES
NO
NO
YES
YES
30CZ2 OFF
OFF
STOP
STOP
52C2
MC2
MF3
ON
CH2
SERVICE CALL
OFF
STOP
STOP
NO
X3 ON?
NO
NO
YES
YES
X1 ON (SELF HOLD)
T3 ON
X2 ON (SELF HOLD)
T4 ON
X3 ON
X4 ON
21S41 OFF
T1 OFF
MF2 STOP
21S42 OFF
T2 OFF
MF3 STOP
ON
PASS
THE 15 MIN ON?
(T3)
NO
NO
26D1 OFF?
Condensing 26±1.5˚C
temp.
or
63H2-1 OFF?
High
pressure 2.16MPa
YES
X1 OFF
T3 OFF
NO
NO
26D2 OFF?
Condensing 26±1.5˚C
temp.
or
63H2-2 OFF?
High
pressure 2.16MPa
YES
YES
X2 OFF
T4 OFF
X3 OFF
X4 OFF
21S41, T1 ON
MF2 OPERATE
21S42, T2 ON
MF3 OPERATE
Note:
When the fault of outdoor unit is occurred, the fan(MF1) of indoor unit continues to work.
But the unit doesn't work correctly (not cooling ).
Then, turn off the power supply and check outdoor unit.
When the fault of indoor unit is occurred, both indoor unit and outdoor unit is stop.
- 65 -
PASS
THE 15 MIN ON?
(T4)
YES
REFRIGERANT SCHEMATICS
PE-7,8,10,20MYC-EU
PE-15MYC1-EU
INDOOR
PE
Evaporator
BRAZING
FRANGE
FLARE
OUTDOOR
PU
Condenser
High
pressure
switch
Service
port
Check
joint
Strainer
Ball valve
COOL
Muffler
Accumulator
Check
joint
Compressor
Capillary
Tube
Strainer
Ball valve
Note:
PE-15MYC1,20MYC-EU is comprised of two refrigerant cycles.
PEH-5,7,8,10,15,20MYA-EU
BRAZING
FRANGE
FLARE
INDOOR
PEH
Evaporator
OUTDOOR
PUH
Condenser
High
pressure
switch
Service
port
Check
joint
Strainer
Strainer
4-Way
valve
High
pressure
switch
(defrost)
Ball valve
HEAT COOL
Muffler
Accumulator
Check
joint
Compressor
Capillary
Tube
Check
valve
Strainer
Capillary
Tube
Check
valve
Ball valve Strainer
Note:
PEH-15,20MYA-EU is comprised of two refrigerant cycles.
- 66 -
SAFETY & CONTROL DEVICES
PE-7,8,10MYC-EU
PE-15MYC1-EU
PE-20MYC-EU
NO.
PE-7MYC-EU
PU-7MYC1-EU
PE-8MYC-EU
PU-8MYC1-EU
PE-10MYC-EU
PU-10MYC1-EU
COMPRESSOR OVER CURRENT RELAY
51C
19.0A
22.0A
31.0A
COMPRESSOR INTERNAL THERMOSTAT
49C
105 ± 5 ˚C OF83 ± 11 ˚C ON
HIGH PRESSURE SWITCH
63H
2.94MPa OFF
INDOOR FAN MOTOR OVER CURRENT RELAY
51F1
INDOOR FAN MOTOR INTERNAL THERMOSTAT
-
150 ˚C OFF
OUTDOOR FAN MOTOR OVER CURRENT RELAY
51F2
2.5A
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
-
150 ˚C OFF
ITEM
FUSE
F1
ITEM
5.0A
3.5A
3
NO.
3.15A
PE-15MYC1-EU PE-20MYC-EU
PU-15MYC1-EU PU-20MYC1-EU
COMPRESSOR OVER CURRENT RELAY
51C1,2
22.0A
31.0A
COMPRESSOR INTERNAL THERMOSTAT
49C
105 ± 5 ˚C OFF
83 ± 11 ˚C ON
HIGH PRESSURE SWITCH
INDOOR FAN MOTOR OVER CURRENT RELAY
63
3.24MPa OFF
51F1
4.6A
7.2A
OUTDOOR FAN MOTOR OVER CURRENT RELAY
51F2,3
2.5A
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
-
150 ˚C OFF
FUSE
F1
3
- 67 -
3.15A
5.0A
PEH-7,8,10MYA-EU
PEH-15,20MYA-EU
ITEM
NO.
PEH-8MYA-EU
PUH-8MYC2-EU
PUH-8MYE1-EU
PEH-5MYA-EU
PEH-7MYA-EU
PUH-5MYE1-EU PUH-7MYC2-EU
COMPRESSOR OVER CURRENT RELAY
51C
15.0A
19.0A
COMPRESSOR INTERNAL THERMOSTAT
49C
110 ± 5˚C OFF
61 ± 9˚C ON
22.0A
105 ± 5˚C OFF
83 ± 11˚C ON
HIGH PRESSURE SWITCH
63H1
2.94MPa OFF
HIGH PRESSURE SWITCH (DEFROST)
63H2
2.16MPa OFF
26D
-4 ± 1.5 ˚C ON,26± 1.5 ˚C OFF
26D1,2
-
FROST PROTECTOR
INDOOR FAN MOTOR OVER CURRENT RELAY
51F1
INDOOR FAN MOTOR INTERNAL THERMOSTAT
-
OUTDOOR FAN MOTOR OVER CURRENT RELAY
51F2
2.5A
-
150˚C OFF
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
FUSE
F1
ITEM
COMPRESSOR OVER CURRENT RELAY
COMPRESSOR INTERNAL THERMOSTAT
5.0A
3.5A
150˚C OFF
3
NO.
51C1,2
3.15A
PEH-10MYA-EU
PEH-15MYA-EU
PUH-10MYC1-EU
PUH-15MYC1-EU
PUH-10MYE-EU
31.0A
63H1-1
PEH-20MYA-EU
PUH-20MYC1-EU
22.0A
31.0A
105 ± 5 ˚C OFF 83 ± 11˚C ON
49C
63H1
HIGH PRESSURE SWITCH
3.5A
2.94MPa OFF
-
-
2.94MPa OFF
2.16MPa OFF
-
-
2.16MPa OFF
63H1-2
63H2
HIGH PRESSURE SWITCH (DEFROST)
63H2-1
63H2-2
26D
FROST PROTECTOR
-4 ± 1.5 ˚C ON,
26 ± 1.5 ˚C OFF
-4 ± 1.5 ˚C ON, 26 ± 1.5 ˚C OFF
26D1,D2
-
INDOOR FAN MOTOR OVER CURRENT RELAY
51F1
5.0A
OUTDOOR FAN MOTOR OVER CURRENT RELAY
51F
2.5A
-
150˚C OFF
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
FUSE
F1
3
- 68 -
4.6A
3.15A
7.2A
SPECIAL ORDER
Description
Model
PEH-5MYA
PEH-7MYA
PEH-8MYA
PEH-10MYA
PEH-15MYA
PEH-20MYA
Service ref.
PEH-5MYA-EU
PEH-7MYA-EU
PEH-8MYA-EU
PEH-10MYA-EU
PEH-15MYA-EU
PEH-20MYA-EU
Heat pump
_
* Low Ambient Cooling
PAC-205FC
Anti corrosion
(Service reference)
(PUH-5MYE1-EUS) (PUH-7MYC2-EUS)
* Low ambient cooling
Description
(PUH-8MYC2-EUS, (PUH-10MYC2-EUS,
(PUH-15MYC2-EUS) (PUH-20MYC2-EUS)
PUH-8MYE1-EUS) PUH-10MYE1-EUS)
It is possible to conduct cooling operation under an outdoor temperature even down to -5 ˚C.
Model
PE-7MYC
PE-8MYC
PE-10MYC
PE-15MYC
PE-20MYC
Service ref.
PE-7MYC-EU
PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU
PE-20MYC-EU
Cooling only
* Low Ambient Cooling
PAC-205FC
_
Anti corrosion
(Service reference)
(PU-7MYC1-EUS)
* Low ambient cooling
(PU-8MYC1-EUS) (PU-10MYC1-EUS) (PU-15MYC1-EUS) (PU-20MYC1-EUS)
It is possible to conduct cooling operation under an outdoor temperature even down to -5 ˚C.
- 69 -
PHYSICAL DATA
PE-7,8,10,20MYC-EU
PE-15MYC1-EU
[ PRODUCT]
Product type
Product number :
PACKAGE AIR COOLED HEATPUMP UNITS
Indoor unit
Outdoor unit
Cooling capacity (AS1861)
Sensible Cooling capacity (AS1861)
Cooling power consumption (Input)
Basic temperature condition cooling
Basic temperature condition cooling
PE-7MYC-EU
PU-7MYC1-EU
17.9
14.3
7.2
kW
kW
kW
Indoor
Outdoor
PE SERIES
PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU
PU-8MYC1-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU
57.6
47.0
22.0
28.8
46.1
37.6
17.6
23.0
7.8
10.1
22.0
17.4
27 DB/19 WB
35 DB
[ ELECTRICAL ]
<Indoor unit>
Design voltage
Cy cles
Power supply
Control voltage
Voltage change
Voltage change
Fan motor output
Fan motor current
Volts
240
Hz
Volts 1PH-240V
Max.
Min.
415
50
3PH-415V
240/24
Volts
240
415
Volts
220
380
HP(kW) 0.28(0.21) 0.94(0.70) 1.34(1.0) 2.95(2.2)
Amps
3.2
1.2
2.0
3.5
4.96(3.7)
4.8
<Outdoor unit>
Design voltage
Cycles
Power supply
Voltage change
Voltage change
Fan motor output
Fan motor current
Max.
Min.
Volts
Hz
Volts
Volts
Volts
HP(kW) 2×0.12(2×0.09)
Amps
0.7
415
50
3PH-415V
415
380
0.32(0.24) 2×0.32(2×0.24)
2×0.2(2×0.15)
1.0
1.2
2×1.2
[COMPRESSOR]
Make
Model
Type
Number of compressor
Nominal motor
Locked rotor current
Normal run current (AS1861)
Swept volume
Bore
Stroke
Speed
Number of cylinders
Oil charge
Type of oil
Crankcase heater
MITSUBISHI
JH519YE JH521YE JH527YE JH521YE JH527YE
HERMETIC LINE START (RECIPROCATING)
1
2
HP(kW) 6.7(5.0)
7.4(5.5) 10.1(7.5)
7.4(5.5) 10.1(7.5)
Amps
76
83
85
85
83
Amps
13.0
15.5
19.2
19.2
15.5
cc/rev
149
160.8
201
201
160.8
mm
ø44.45
mm
24.0
25.9
rpm
2900
4
5
4
5
ml
3000
4500
3000
4500
DIAMOND MS32(N-1) OR SUNISO 3GS(D)
watts
62
72
62
72
[REFRIGERATION SYSTEM]
Refrigerant
Refrigerant charge per circuit
Number of refrigerant control
Refrigerant control
Limit of pipe’s length
Limit of pipe’s height difference
kg
5.7
m
mtrs
mtrs
- 70 -
5.0
1
R22
8.7
4.8
9.7
2
Capillary tube
50
20 (In case of indoor unit above outdoor unit)
30 (In case of outdoor unit above indoor unit)
Product number
Indoor unit
PE-7MYC-EU
PU-7MYC1-EU
Outdoor unit
PE-8MYC-EU
PU-8MYC1-EU
PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU
PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU
[INDOOR AIR CIRCUIT]
Number of blowers
Diameter of blowers
Width of blowers
Blower drive
Fan motor output
Fan motor run current
Air quantity
External static pressure
Supply air dimensions(hxw)
Return air dimensions(hxw)
[EVAPORATOR]
Number of evaporator
Face area
Rows deep
Rows high
Finned length
Face velocity
Fin per meter
Fin material thickness
Fin material/Type
Tube diameter
Gauge of copper tube
Pipe type
Number of circuit
[OUTDOOR AIR CIRCUIT]
Number of fans
Diameter of fan
Blower drive
Quantity of motor
Fan motor output
Fan motor run current
Air quantity
[CONDENSER]
Number of condensers
Face area
Rows deep
Rows high
Finned length
Face velocity
Fin per meter/Pitch
Fin material thickness
Fin material/Type
Tube diameter/Gauge
Pipe type
Number of circuit
2
380
270
374
275
Direct drive
Belt drive
3.7
2.2
1.00
0.70
0.21
4.8
3.5
2.0
1.2
3.2
3000
2333
1500
1167
1000
100/200
50/125
62/125
341× 1302 412×1000 412×1209
341 × 1102
248 × 998
596×1415
mm
mm
250
245
kW
A
L/s
Pa
mm
mm
sq.m
1
0.50
0.42
4
0.86
1.00
4
24
15
1300
1615
1415
3.0
2.7
3.0
513/1.95
513/1.95 474/2.11
0.115
Aluminium / Ring
9.52
0.35
Plain tube
Groove tube
10
16
24
mm
m/s
1100
2.2
2.8
474/2.11
mm
mm
mm
1
2
mm
2
600
954
Direct drive
2
kW
A
L/s
2×0.09
0.7
3167
2×0.15
1.0
3000
3667
1
0.24
1.2
4000
2
2×0.36
2×1.2
8000
2
sq.m
2×2.1
1
30
mm
m/s
32
2706
1.4
474 / 2.7
mm
mm
- 71 -
2
30
2696
1.5
625 / 1.6 538 / 1.86
0.115
Aluminium / Ring
9.52 / 0.35
Groove tube
7
11
1.32
2
40
1299
1.5
6.25/1.6
1.35
2
30
1775
3.0
Plain tube
6
Product number
Indoor unit
Outdoor unit
PE-7MYC-EU
PU-7MYC1-EU
PE-8MYC-EU
PU-8MYC1-EU
PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU
PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU
[ENCLOSURE AND FRAME]
Dimension
Dimension
Indoor unit
Outdoor unit
External finish
(indoor unit)
(outdoor unit)
External finish
Panel thickness
Condense drain size
Wei ght Indoor unit
Wei ght Outdoor unit
Sound pressure level (indoor unit)
Sound pressure level (outdoor unit)
Sound power level (indoor unit)
Sound power level (outdoor unit)
width
depth
height
width
depth
height
mm
mm
mm
mm
mm
mm
1415
1615
650
428
1400
700
980
1690
1993
865
706
998
1996
998
1230
961
Galvanized steel
Acrylic resin coationg (Color: Munsell 5Y8/1)
1.2
25.4
67
70
84
212
180
202
205
230
360
285
55
56
59
62
61
65
65
65
68
67
63
64
67
70
69
76
76
76
79
78
mm
mm
kg
kg
dbA
dbA
dbA
dbA
- 72 -
PEH-5,7,8MYA-EU
[ PRODUCT]
Product type
Product number :
PACKAGE AIR COOLED HEATPUMP UNITS
Indoor unit
Outdoor unit
Cooling capacity (AS1861)
Sensible Cooling capacity (AS1861)
Cooling power consumption (Input)
Heating capacity (AS1861)
Heating power consumption
Basic temperature condition cooling
Basic temperature condition cooling
Basic temperature condition heating
Basic temperature condition heating
kW
kW
kW
kW
kW
PEH-5MYA-EU
PUH-5MYE1-EU
14.4
11.5
5.5
14.4
4.5
Indoor
Outdoor
Indoor
Outdoor
PEH SERIES
PEH-7MYA-EU
PEH-8MYA-EU
PUH-7MYC2-EU
PUH-8MYC2-EU
PUH-8MYE1-EU
17.9
22.0
14.3
17.6
7.8
7.9
7.2
22.0
18.8
6.5
6.3
27 DB/19 WB
35 DB
21 DB
7
DB/6 WB
[ ELECTRICAL ]
<Indoor unit>
Design voltage
Cy cles
Power supply
Control voltage
Voltage change
Voltage change
Fan motor output
Fan motor current
Volts
Hz
Volts
Max.
Min.
Volts
Volts
HP(kW)
Amps
415
240
415
50
3PH-415V
415
380
0.6(0.45)
1.1/1.0
1PH-240V
240/24
240
220
0.28(0.21)
3.2
3PH-415V
415
380
0.94(0.70)
1.2
<Outdoor unit>
Design voltage
Cycles
Power supply
Voltage change
Voltage change
Fan motor output
Fan motor current
Max.
Min.
Volts
Hz
Volts
Volts
Volts
HP(kW)
Amps
0.2(0.15)
1.0
415
50
3PH-415V
415
380
2×0.12(2×0.09)
0.7
0.47(0.35)
[COMPRESSOR]
Make
Model
Type
Number of compressor
Nominal motor
Locked rotor current
Normal run current (AS1861)
Swept volume
Bore
Stroke
Speed
Number of cylinders
Oil charge
Type of oil
Crankcase heater
HP(kW)
Amps
Amps
cc/rev
mm
mm
rpm
ml
watts
Copeland
MITSUBISHI
JH519YE
CRNQ-0500-TFD
JH521YE
HERMETIC LINE START (RECIPROCATING)
1
5.0(3.73)
6.7(5.0)
7.4(5.5)
65
76
83
8.6
13.0
15.5
101.92
149
160.8
ø49.78
ø44.45
25.9
26.19
24.0
2900
2
4
1952
3000
DIAMOND MS32(N-1) OR SUNISO 3GS(D)
CALUMET RO 15 OR WITCO 3GS
40
62
[REFRIGERATION SYSTEM]
Refrigerant
Refrigerant charge per circuit
Number of refrigerant controls
Refrigerant control
Reverse cycle valve
Defrost system
Limit of pipe's leng th
Limit of pipe's height difference
R22
kg
6.6
1
Capillary tube
4-way valve
Reverse cycle defrost
50
20 (In case of indoor unit above outdoor unit)
30 (In case of outdoor unit above indoor unit)
5.0
m
mtrs
mtrs
- 73 -
5.7
Product number
Indoor unit
Outdoor unit
PEH-5MYA-EU
PUH-5MYE1-EU
PEH-7MYA-EU
PUH-7MYC2-EU
PEH-8MYA-EU
PUH-8MYC2-EU
PUH-8MYE1-EU
[INDOOR AIR CIRCUIT]
Number of blowers
Diameter of blowers
Width of blowers
Blower drive
Fan motor output
Fan motor run current
Nominal air quantity
External static pressure
Supply air dimensions(hxw)
Return air dimensions(hxw)
[EVAPORATOR]
Number of evaporator
Face area
Rows deep
Rows high
Finned length
Face velocity
Fin per meter / pitch
Fin material thickness
Fin material/Type
Fin coating
Tube diameter
Gauge of copper tube
Pipe type
Number of circuit
[OUTDOOR AIR CIRCUIT]
Number of fans
Diameter of fan
Blower drive
Quantity of motor
Fan motor output
Fan motor run current
Nominal air quantity
[CONDENSER]
Number of condensers
Face area
Rows deep
Rows high
Finned length
Face velocity
Fin per meter/Pitch
Fin material thickness
Fin material/Type
Tube diameter/Gauge
Pipe type
Number of circuit
1
mm
mm
275
0.45
1.1/1.0
700
50/125
kW
A
L/s
Pa
mm
mm
342×781
248×498
sq.m
0.3
2
250
245
Direct drive
0.21
3.2
1000
50/125
275
0.70
1.2
1167
62/125
341×1102
248×998
342×1118
1
0.42
4
15
780
2.5
513/1.95
mm
m/s
15
1100
2.2
474/2.11
0.115
Aluminium / Ring
NA 510 D *1
mm
mm
mm
9.52
0.35
Plain tube
Groove tube
7
1
mm
kW
A
L/s
1
0.35
1.2
1583
sq.m
1
1.3
mm
m/s
1100
2.8
474/2.11
44
1000
1.56
513/1.95
mm
mm
11
2
600
Direct drive
2
2×0.09
0.7
2783
2
2×2.1
2
30
2706
1.35
474 /2.11
0.115
Aluminium / Ring
9.52 / 0.35
Groove tube
7
Specifications subject to change without noice
*1 Corrosion proof property : Salt spray JIS Z 2371, 500hrs Humiditiy test 50C 98% 500hrs.
*2 Corrosion proof property : Salt spray JIS Z 2371, 1000hrs Humiditiy test 50C 98% 1000hrs.
- 74 -
Groove tube
10
1
800
1
0.35
1.2
3333
1
1.58
44
1400
1.95
513 /1.95
11
Product number
Indoor unit
Outdoor unit
PEH-5MYA-EU
PUH-5MYE1-EU
PEH-7MYA-EU
PUH-7MYC2-EU
PE-8MYA-EU
PUH-8MYC2-EU
PUH-8MYE1-EU
[ENCLOSURE AND FRAME]
Dimension
Indoor unit
Dimension
Outdoor unit
External finish
(indoor unit)
(outdoor unit)
External finish
Panel thickness
Condense drain size
Weight Indoor unit
Weight Outdoor unit
Sound pressure level (indoor unit )
Sound pressure level (outdoor unit )
Sound power level (indoor unit )
Sound power level (outdoor unit )
width
depth
height
width
depth
height
mm
mm
mm
mm
mm
mm
mm
mm
kg
kg
dbA
dbA
dbA
dbA
- 75 -
1095
1415
650
428
1250
1000
1400
550
550
700
1175
1175
980
Galvanized steel
Acrylic resin coationg (Color: Munsell 5Y8/1)
1.2
25.4
70
60
67
214
150
211
188
55
56
57
65
63
64
68
76
PEH-10,15,20MYA-EU
[ PRODUCT]
Product type
Product number :
PACKAGE AIR COOLED HEATPUMP UNITS
PEH SERIES
PEH-15MYA-EU
PEH-10MYA-EU
PUH-15MYC2-EU
PUH-10MYC2-EU
PUH-10MYE1-EU
44.0
28.8
35.2
23.0
10.1
10.2
16.9
28.8
44.0
8.3
14.1
27 DB/19 WB
35 DB
21 DB
7
DB/6 WB
Indoor unit
Outdoor unit
Cooling capacity (AS1861)
Sensible Cooling capacity (AS1861)
Cooling power consumption (Input)
Heating capacity (AS1861)
Heating power consumption
Basic temperature condition cooling
Basic temperature condition cooling
Basic temperature condition heating
Basic temperature condition heating
kW
kW
kW
kW
kW
Indoor
Outdoor
Indoor
Outdoor
PEH-20MYA-EU
PUH-20MYC2-EU
57.6
46.0
21.8
57.6
19.3
[ ELECTRICAL ]
<Indoor unit>
Design voltage
Cy cles
Power supply
Control voltage
Voltage change
Voltage change
Fan motor output
Fan motor current
Volts
Hz
Volts
Max.
Min.
Volts
Volts
HP(kW)
Amps
415
50
3PH-415V
240/24
415
380
1.34(1.0)
2.95(2.20)
2.0
4.1
1.34(1.0)
2.0
4.96(3.70)
4.7
<Outdoor unit>
Design voltage
Cycles
Power supply
Voltage change
Voltage change
Fan motor output
Fan motor current
Max.
Min.
Volts
Hz
Volts
Volts
Volts
HP(kW) 2×0.2(2×0.15)
Amps
1.0
415
50
3PH-415V
415
380
0.47(0.35)
1.2
2×0.47(2×0.35)
2×1.2
[COMPRESSOR]
Make
Model
Type
Number of compressor
Nominal motor
Locked rotor current
Normal run current (AS1861)
Swept volume
Bore
Stroke
Speed
Number of cylinders
Oil charge
Type of oil
Crankcase heater
HP(kW)
Amps
Amps
cc/rev
mm
mm
rpm
ml
watts
MITSUBISHI
JH527YE
JH521YE
JH527YE
HERMETIC LINE START (RECIPROCATING)
1
2
10.1(7.5)
10.1(7.5)
7.4(5.5)
85
85
83
19.2
19.2
15.5
201
160.8
201
ø44.45
25.9
2900
5
4
5
4500
3000
4500
DIAMOND MS32(N-1) OR SUNISO 3GS(D)
72
62
72
[REFRIGERATION SYSTEM]
Refrigerant
Refrigerant charge per circuit
Number of refrigerant controls
Refrigerant control
Reverse cycle valve
Defrost system
Limit of pipe's leng th
Limit of pipe's height difference
R22
kg
9.9
1
m
mtrs
mtrs
- 76 -
6.6
9.7
2
Capillary tube
4-way valve
Reverse cycle defrost
50
20 (In case of indoor unit above outdoor unit)
30 (In case of outdoor unit above indoor unit)
Product number
Indoor unit
Outdoor unit
PEH-15MYA-EU
PUH-15MYC2-EU
PEH-10MYA-EU
PUH-10MYC2-EU
PUH-10MYE1-EU
PEH-20MYA-EU
PUH-20MYC2-EU
[INDOOR AIR CIRCUIT]
Number of blowers
Diameter of blowers
Width of blowers
Blower drive
Fan motor output
Fan motor run current
Nominal air quantity
External static pressure
Suppl y air dimensions(hxw)
Return air dimensions(hxw)
[EVAPORATOR]
Number of evaporator
Face area
Rows deep
Rows hi gh
Finned length
Face velocit y
Fin per meter / pitch
Fin material thickness
Fin material/Type
Fin coating
Tube diameter
Gau ge of copper tube
Pipe t ype
Number of circuit
[OUTDOOR AIR CIRCUIT]
Number of fans
Diameter of fan
Blower drive
Quantit y of motor
Fan motor output
Fan motor run current
Nominal air quantity
[CONDENSER]
Number of condensers
Face area
Rows deep
Rows high
Finned length
Face velocity
Fin per meter/Pitch
Fin material thickness
Fin material/Type
Tube diameter/Gauge
Pipe type
Number of circuit
2
mm
mm
kW
A
L/s
Pa
mm
mm
250
275
Direct drive
1.00
1.00
2.0
1.8
1500
1500
62/125
341×1302
342×1318
248×998
sq.m
1
0.50
280
245
275
Belt drive
3.70
4.7
3000
2.20
4.5
2333
100/200
412×1000
412×1209
596×1415
2
0.86
0.98
4
15
1300
3.0
513/1.95
mm
m/s
24
1415
2.7
513/1.95
1615
3.0
592/1.69
0.115
Aluminium / Ring
NA 510 D *1 (NA 549 *2)
mm
mm
mm
9.52
0.35
Groove tube
16
Plain tube
10
2
600
1
mm
kW
A
L/s
2
2×0.15
1.0
3167
1
0.35
1.2
3333
sq.m
2
2×2.1
1
1.58
24
2
800
Direct drive
2
2×0.35
1.3
2X3083
2
2×1.32
2×1.07
3
mm
m/s
30
2706
1.35
474/2.11
mm
mm
11
44
1400
1.95
513/1.95
2.89
0.115
Aluminium / Ring
9.52 / 0.35
Groove tube
11
16
Specifications subject to change without noice
*1 Corrosion proof property : Salt spray JIS Z 2371, 500hrs Humiditiy test 50˚C 98% 500hrs.
*2 Corrosion proof property : Salt spray JIS Z 2371, 1000hrs Humiditiy test 50˚C 98% 1000hrs.
(anti corrosion as special order)
- 77 -
37
2800
2.34
474 /2.11
14
Product number
Indoor unit
Outdoor unit
PEH-10MYA-EU
PUH-10MYC2-EU
PUH-10MYE1-EU
PEH-15MYA-EU
PUH-15MYC2-EU
1615
650
428
1690
PEH-20MYA-EU
PUH-20MYC2-EU
[ENCLOSURE AND FRAME]
Dimension
Indoor unit
Dimension
Outdoor unit
External finish
(indoor unit)
(outdoor unit)
External finish
Panel thickness
Condense drain size
Weight Indoor unit
Weight Outdoor unit
Sound pressure level (indoor unit )
Sound pressure level (outdoor unit )
Sound power level (indoor unit )
Sound power level (outdoor unit )
width
depth
height
width
depth
height
mm
mm
mm
mm
mm
mm
1250
550
1175
Galvanized steel
Acrylic resin coationg (Color: Munsell 5Y8/1)
1.2
25.4
180
212
84
221
240
431
472
61
62
59
69
65
70
69
67
76
80
1400
700
980
mm
mm
kg
kg
dbA
dbA
dbA
dbA
- 78 -
1993
865
706
1951
1080
1200
INSTALLATION
1. Space required around unit
Indoor unit
Dimension of the unit and space necessary for sevicing.
PE(H)-15,20
200
946
380
746
530
730
200
PEH-5 PE(H)-7, 8, 10
180
B
400
200
B
A
500
500
928
1206
706
428
100
100
A
Ceiling access panel
PEH - 5
A
B
1560
1000
PE(H) - 7, 8
1880
1320
PE(H) - 10
2080
1520
Ceiling access panel
A
B
PE(H) - 15
2187
1587
PE(H) - 20
2490
1890
Outdoor unit
Secure enough space necessary for servicing, installing, and for proper function of the unit.
To prevent short-cycling, remove obstacles as much as possible.
PUH-5, 8, 10 (Side blow)
(1) At a single installation
Service panel
150 over
500 over
Inlet surface
150 over
Inlet
surface
Inlet
surface
Service panel
Inlet surface
150 over
300 over
Outlet surface
Outlet surface
With the inlet surface facing a wall.
With the outlet surface facing a wall.
(2) Relation of unit when many set up unit.
300
over
500 over
500 over
500 over
Please set the unit that the inlet air and the outlet air are not influenced.
- 79 -
500 over
PU(H)-7,8, 10 (Upper blow)
(1) At a single installation
300
over
The obstacle is on the outlet side. (Fig 1)
The obstacle is in three directions. (Fig 2,3)
The obstacle is in four directions. (Fig 4)
ceiling
1200
over
The right and left side
and the back and forth
side must be opened.
300 over
500 over
However, the
outlet side must
be opened.
Service Panel
Fig 2
Fig 1
300 over
A
If this side is service
panel, you need 500
over. If this side is inlet,
you need 300 over.
300 over
A
However, if the service
panel is an interior side,
the right or left side
need 500 over.
All “A” is 500 over.
However, outlet side
must be opened.
And the obstacle in
two directions must be
lower than the unit.
A
A
Fig 3
Fig 4
300 over
(2) Relation of unit when many set up unit. (Fig 5,6,7)
If this side is
service panel,
you need 500 over.
If this side is inlet,
you need 300 over.
500
over
A
300 over
A
A
Fig 6
Fig 5
A
A
300 over
All “A” is 500 over.
300 over
500 over
500 over
Service-panel
A
A
Fig 7
A
All “A” is 500 over in any case.
- 80 -
A
Service-panel
300 over
PU-15
(1) At a single installation
The obstacle is on the outlet side. (Fig 1)
The obstacle is in four directions. (Fig 2)
300 over
ceiling
However, the outlet
500 over side must be opened.
1500
over
The right and left side
and the back and forth
side must be opened.
300 over
300 over
Service Panel
Fig 1
Fig 2
300over
(2) Relation of unit when many set up unit. (Fig 3,4)
500over
Service-panel
500
over
300 over
If this side is service panel, you
need 500 over.
If this side is inlet, you need 300 over.
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
A
A
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
A
300 over
Fig 4
Service-panel
All “A” is 500 over.
Fig 3
PU-20
(1) At a single installation
The obstacle is on the outlet side. (Fig 1)
The obstacle is in four directions. (Fig 2)
300 over
However, the outlet
side must be opened.
ceiling
500 over
1500
over
300 over
300 over
The right and left side
and the back and forth
side must be opened.
Service Panel
Fig 2
Fig 1
300 over
(2) Relation of unit when many set up unit. (Fig 3,4,5)
300 over
Service-panel
300 over
500
over
500 over
300 over
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
A
A
A
A
Service-panel
Fig 4
Fig 3
All “A” is 500 over.
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
300 over
A
Fig 5
A
A
All “A” is 500 over in any case.
- 81 -
300 over
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
PUH-15, 20
(1) At a single installation
The obstacle is on the outlet side. (Fig 1)
The obstacle is in four directions. (Fig 2)
The obstacle is in three directions. (Fig 3,4)
ceiling
1500
over
500 over
The right and left side
and the back and forth
side must be opened.
300 over
300 over
However, outlet side
must be opened.
And the obstacle in
two directions must be
lower than the unit.
Service Panel
Fig 2
Fig 1
However, the outlet side must be opened.
300 over
Service-panel
300 over
300 over
500 over
Service-panel
Fig 3
Fig 4
300 over
(2) Relation of unit when many set up unit. (Fig 5,6,7)
Service-panel
300 over
500
over
500 over
300 over
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
A
A
A
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
A
Service-panel
Fig 6
Fig 5
All “A” is 500 over.
If this side is
service panel, you
need 500 over.
If this side is inlet,
you need 300 over.
300 over
A
Fig 7
A
A
300 over
All “A” is 500 over in any case.
2. Preparation before installing
Indoor unit
Reinforcement
Please use the specified hanging bolt in any case.
Hanging bolt is local supply.
Please use the method below or use the angle and the
rectangular lumber, etc. and install the hanging bolt.
Insert etc
100-150kg
- 82 -
Hanging bolt
M10 (PEH-5,PE(H)-7,8,10)
M12 (PE(H)-15,20)
3. Installation of the unit.
Indoor unit
Please carry the packed until parallelly to installed place.
Please install the unit before construction of the ceiling -lined.
PEH-5 PE(H)- 7, 8, 10
100
over
100
over
U washer
Nut
30
30
Washer
Nut
100
over
PE(H)-15, 20
Nut (M10)
Nut (M10)
Washer
30
Washer
Nut (M10)
Ceiling
Nut (M10)
Outdoor unit
Fix unit tightly with bolts as shown below so that unit will be securely fixed
in place use concrete or angle foundation of unit.
At the time of bottom piping of refrigerant pipe, build a 100mm or higher
foundation so that piping will go through bottom of unit.
Anchor bolt (local arrangement)
PUH-5 PU(H)-7, 8, 10
M8
PU(H)-15, 20
M10
Installation pitch
Concrete foundation
- 83 -
Duct construction
Provide canvas flexible ducting between unit when connect to the duct-work.
The duct unit must use a nonflammable material.
Provide sufficient insulation for prevent dewdrop.
Duct earth
Duct earth
Canvas Duct
Canvas Duct
Duct
Duct
Drain pan
Inlet
Outlet
Duct-work length 850mm or more
Lifting method
When the unit is to be lifted and moved, attach ropes to the suspension plates(3 p.c.s)
provided on the top of the unit.
When the unit is lifted, it 's center of gravity tends to shift the unit one side and so balance,
such as that in the figure below, should be attained.
The angles at which the ropes suspend the unit should be at least 60º at the compressor end
and at least 45º at the condenser end. Care should be taken to avoid contact with the main unit
while carrying.
It is necessary to protect the unit with the blanket so that the ropes should not injure the unit.
Hook (as directly aligned over
the center of gravity as possible.
MITSUBISHI
ELECTRIC
PUH-5,8,10 (side blow)
PUH-7,8,10 (upper blow)
- 84 -
PUH-15,20
(PU-15,20 is same method.)
Piping connection
Warning
Please follow the following procedures, during the piping connection work is carried out. If the procedures are
not followed properly, the refrigerant and valve sheet might gush out from the ball valve. It might cause the injury.
1. PROCEDURE TO CONNECT THE EXTENSION PIPE
Proceed with the connection as follows.
(1) Open the ball valve cap at first. (Fig. 1)
(2) Check the ball valve section is completely closed. (Fig. 2)
Valve knob
Fig. 1
Valve knob
Close
Open
Pin
Pin
Fig. 3
Fig. 2
(3) Remove the connection pipe assy. (Fig. 4)
Throw away the packing. (Except the PUH-5)
Caution:
There will be small amount of refrigerant gushed out of the by-pass tube at the moment. Loosen and tighten the
flare nut using a double-ended wrench. (Fig. 7 and Table. 1)
Coat the flare contact surface and both surface of packing with refrigerator oil.
Do not brazing work before removing the connection pipe assy. (Except the PUH-5)
(4) Remove the by-pass tube. (Except the PUH-5) (Fig. 5)
Braze the extension pipe with the flange assy. (Except the PUH-5)
(5) Connect the extension pipes with the ball valves (the flare nut type).
(Only the PUH-5) (Fig. 6)
Connect the extension pipes with the ball valves (the flare nut and the flange type). (Fig. 6) Use the attached
new packing certainly between the ball valve and the flange.
Connection Pipe assy
Unit side
Unit side
Extension pipe
PUH-5
Connection Pipe assy
Unit side
Unit side
By-pass tube
Extension pipe
PU(H)
8-20
Flange assy
Extension pipe
Packing (throw away)
Fig. 4
Fig. 5
use the attached new packing
Fig. 6
2. HANDLING PRECAUTIONS
(1) The extension pipes should be connected under closing condition. (Fig. 2)
Do leak test the part of flange and flare.
(2) Before charging the refrigerant, vacuum the extension pipes and indoor side to clear all
the air and water.
(3) Charge the additional amount of refrigerant according to the installation manual.
Fig. 7
(4) Do leak test again.
(5) Turn the ball valve knob to “Open” position. (Fig. 3)
pipe diameter
Tightening torque
(6) Finally, put the cap back to the ball valve.
(mm)
(Nm) / (kgcm)
6.35
9.52
12.7
15.88
19.05
14 to 18 / 140 to 180
35 to 42 / 350 to 420
50 to 57.5 / 500 to 575
75 to 80 / 750 to 800
100 to 140/1000 to1400
Table. 1
- 85 -
4. Refrigerant piping
Extension piping and installation parts are field supply.
C
Perform the work only after carefully reading the
appropriate instructions.
A
Install the unit where the refrigerant piping is shortest,
When the outdoor unit is lower
the difference between the indoor unit and outdoor unit
is smallest.
As pipes purchased in the market may contain
dust, below them off with dry inlet gas.
C
Take care not to allow dust and water content to enter
the piping during pipe processing or installing.
Minimize the number of bends, and make the bending
B
radius as long as possible.
Always observe the restriction(allowable length, height
difference, pipe diameter) on the refrigerant piping.
When the outdoor unit is higher
For soldering & brazing, use high-quality materials.
Never purge air with a refrigerant. Always use a vacuum pump for purging.
Provide proper insulation to the piping . Insufficient insulation cause poor cooling/heating
performance or condensation drip, leading to unexpected trouble.
Do not insulate gas or low pressure pipe and liquid or high pressure pipe together.
For the connection of the refrigerant piping, leave the valve of the outdoor unit fully closed
(as set before shipment), and no operate it until the connection between the indoor/outdoor
units and refrigerant piping, refrigerant leak test and evacuation work have been completed.
The maximum permissible values are shown below.
Remove the cover (grommet) attached sheet metal at exit of heat exchanger pipe of indoor
unit before connecting the local piping.
(This cover is protect the pipe from sheet metal edge at unit transportation.)
Please insulate liquid pipe & gas pipe (two places for each) with an insulated pipe of the
attachment after connecting piping.
Bad example
Good example
Insulating material
Finishing tape
Insulating material
Finishing tape
Liquid pipe
Liquid pipe
Gas pipe
Gas pipe
Electric wire
PEH-5
Electric wire
PE(H)-7 PE(H)-8 PE(H)-10 PE(H)-15 PE(H)-20
Dimension
A (m)
20
20
20
20
20
20
Dimension
B (m)
30
30
30
30
30
30
Number of bends
15
15
15
15
15
15
Total piping length (m)
50
50
50
50
50
50
12.7
15.88
15.88
15.88
19.05
25.4
25.4
28.6
Piping Liquid pipe (mm)
size
Gas pipe (mm)
- 86 -
2×15.88 2×15.88
2×25.4
2×28.6
Airtight test
Airtight test should be made by pressurizing nitrogen gas to 3Mpa.
For the test method, refer to the following figure.
(Make a test with the valve closed. Be also sure to pressurize both liquid and gas pipe.)
The test result can be judged good if the pressure has not been reduced after leaving
for about one day after completion of nitrogen pressurization.
a.
Nitrogen gas
b.
To indoor unit
c.
System analyzer
d.
Low knob
e.
High knob
f.
g.
Valve
Liquid gas
h.
Gas pipe
i.
j.
Outdoor unit
f
g
b
i
h
c
e
d
a
j
Service port
Evacuation
Evacuation should be made from the service port provided on the outdoor unit's valve to
the vacuum pump commonly used for both liquid pipe and gas pipe.
(Make evacuation from both liquid pipe and gas pipe with valve closed.)
Remember :Never carry out air purge by refrigerant.
a.
System analyzer
b.
To indoor unit
c.
Low knob
d.
High knob
e.
Valve
Liquid gas
f.
g.
e
b
f
h
g
a
c
d
Gas pipe
h.
Outdoor unit
i.
j.
Vacuum pump
i
j
Service port
Additional refrigerant charge
The mount of refrigerant charged in this unit is a appropriate for 5-meter long refrigerant pipes.
Refer to the table below and add the corresponding amount of refrigerant if the pipes are
extended.
(The refrigerant is charged in the outdoor unit.)
The outdoor unit of PE-5,8,10 have side
blow type and upper blow type.
Factory charge refer to the table below.
Factory charge
Refrigerant piping length
unit
PU-7
PU-8
PU-10
charge PU-15
mount
PU-20
R-22
(kg) PUH-5
PUH-7
PUH-8
PUH-10
PUH-15
PUH-20
5m
Outdoor unit
10m 15m 20m 25m 30m 35m 40m 45m 50m
Side blow
0
0
0.8
1.6
2.4
3.2
4.0
4.8
5.6
6.4
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
0
0.8
1.6
2.4
3.2
4.0
4.8
5.6
6.4
7.2
0
0.8
1.7
2.5
3.3
4.2
5.0
5.8
6.7
7.5
0
2×0.8 2×1.7 2×2.5 2×3.3 2×4.2 2×5.0 2×5.8 2×6.7 2×7.5
- 87 -
PU-7
PU-8
7.2
2×0.8 2×1.6 2×2.4 2×3.2 2×4.0 2×4.8 2×5.6 2×6.4 2×7.2
Upper blow
charge
mount
R-22
(kg) PUH-5
PUH-8
PUH-10
5.7
5.0
PU-10
8.7
PU-15
PU-20
2×4.8
2×9.7
5.0
6.6
9.9
PUH-7
5.7
PUH-8
PUH-10
PUH-15
6.6
11.0
2×6.6
PUH-20
2×9.7
5. Drain piping
•Incline the drain piping to the outside (drain side) as shown in the figure below.
•The outlet of the indoor unit drain pipe is Rc1.
•After completion of piping, confirm that drainage is good and that there are no leaks.
Indoor unit drain piping
Install thermal insulation
to prevent dew
The drain piping should have a drain trap.
C
Slope
20mm/m
A
Drain pan
Drain piping
B
A>
= 70mm
B>
= 2×C >
= 70mm
C>
= 35mm
Drain trap
The drain pipe
should extend
below this level.
- 88 -
Open drain
6. Electric wiring
Construct the earth connection.
All electrical work must be carried out by a suitable qualified electrical trades-person and in
accordance with local supply authority requirements and associated regulators.
The range of working voltage is within 10% voltage of power supply.
The outdoor unit is to be wired directly from an electrical distribution board either by a circuit
breaker (preferred) or HRC fuse.
Fix power source wiring to control box by using buffer bushing for tensible force (PG
connection or the like). Connect control wiring to control terminal block through the knockout
hole of control box using ordinary bushing.
Note:
Earth wiring must be connected.
Arrangement such as terminal block in control box
Control module of indoor unit
PEH-5, PE(H)-7, 8,10
Control module of indoor unit
PE(H)-15, 20
PE(H)-7 only
Terminal block for
connection wires to
Outdoor unit and remote
controller
PEH-15, 20 only
30FZ
F1(3.15A)
Terminal block for
connection wires to
Outdoor unit and
remote controller
F2(3.15A)
F2(3.15A)
TB3
11 12 13 14 1 2 3 4 5 6
30FZ
Tr
PEH only
52F,51F1
Terminal block for
power supply wires
Terminal block for
power supply wires
FZ
TB2
HZ1
L
CZ1
CZ1-1
F1(3.15A)
IN CASE OF G03
CZ1-2
HZ1-1
PEH-15, 20 52F&51F1
PE-15, 20 52F1&51F1
52F&51F
HZ1-2
PEH-15, 20 HZ1-1
PE-15, 20
FZ
TB2
L1
N
Tr
FZ
C
L2
L3
N
PEH-15,20 only
Screw for earth
connection
Bush and band for the
power supply
Bush for the thermistor
Screw for earth
connection
Bush and band for the
power supply
Bush and band for the connection wires
to Outdoor unit and remote controller
Bush and band for the connection wires
to Outdoor unit and remote controller
Control module of outdoor unit (PUH-5, 8, 10)
Side blow
T1
T2
F3
Screw for earth
connection
51F2
26D
X2
30CZ
CZ2
HZ2
F3 3.15A
52C
&
51C
X1
TB5&6
TB1
Terminal block
for power supply
wires
Terminal block for
connection wires
to Indoor unit
Bush for the thermistor
Band for wires
- 89 -
Control module of outdoor unit PU-15
Control module of outdoor unit PU(H)-7, 8, 10
Upper blow
In case of PU-7, 8, 10
In case of PUH-7, 8, 10
Terminal block for
power supply wires
F3
F3
52C
&
51C
F3 3.15A
F3 3.15A
52C
&
51C
F3
2
52C1
&
51C1
T1
F3 3.15A
52C2
&
51C2
TB1
L1
51F2
Terminal block for
connection wires to
Indoor unit
51F2
L2
L3
30CZ1 30CZ2
CZ CZ
2-1 2-2
N
TB4&5
11
X1
X2
12
13
N
N
30CZ
26D
Screw for earth
connection
TB1
L1
L2
L3
Screw for
earth
connection
N
Band for
wires
TB1
Terminal block for
connection wires
to Indoor unit
Band for wires
Screw for
earth
connection
Terminal block
for power
supply wires
Terminal block
for power
supply wires
Control module of outdoor unit PU-20
Control module of outdoor unit PUH-15,20
52F2
&
51F2
52C2
&
51C2
Screw for earth
connection
51F3
52C1
&
51C1
51F2
52C2
&
51C2
T1
T2
2
T3
X3 X4
T4
F3
51F3
52C1
&
51C1
2
30CZ1 30CZ2
26D1
26D2
F3(3.15A)
X1
TB1
L1
Screw for earth
connection
CZ2-1 CZ2-2
TB4&5
111213 N N
F3
TB1
L1
Terminal block for
power supply wires
L2
L3
N
L2
L3
X2
30CZ1 30CZ2
TB4&5
N
11121314 N N N N FC
CZ
2-1
CZ HZ2
2-2
Terminal block for
connection wires
to Indoor unit
F3(3.15A)
Terminal block for
power supply wires
Band for wires
- 90 -
Band for wires
Terminal block for
connection wires
to Indoor unit
Method for connecting electric wire
Please do the wiring after consulting the electric power
company of jurisdiction beforehand in the instruction.
(1) The entire wiring diagram of unit.
a
a
b
b
PE
PE
j
d
c
j
In case of PE-7,8,10
In case of PE-15,20
PEH-5, 7, 8, 10
g
a.
Power supply
b.
Main switch/fuse (field supply)
c.
Power supply wiring for outdoor unit
d.
Power supply wiring for indoor unit
e.
Outdoor unit
f.
Indoor unit
g.
Connection wiring for indoor
/ outdoor units (polarity)
h.
LCD remote controller
i.
Connection wiring for indoor
/ remote controller (no polarity)
j.
Earth
In case of PEH-15,20
e
i
In case of PE-7, 8, 10
f
In case of PE-15, 20
PEH-5, 7, 8, 10
h
In case of PEH-15, 20
(2) Power supply construction and electric wiring connection of indoor and outdoor unit.
In case of
PEH-5
PE(H)-7,8,10
B
A
3phase
PE(H)-7:Single phase
PEH-5
PE(H)-7,8,10
PE(H)-15,20
G
H
L1 L2 L3 N PE
13 14
15A
15A
30A
In case of PE(H)-15,20
H
15
11 12
13 14
C
C
PEH only
PEH only
D 3 phase
PUH-5
PU(H)-7,8
PU(H)-10
PU(H)-15
PU(H)-20
50A
50A
60A
100A
125A
E
L1 L2 L3 N PE
13 14
G
H
F
A.
Indoor unit
B.
Power cable wiring
C.
Control cable wiring
(Fixing wire-- Do not remove)
D.
Outdoor unit
E.
Earth leakage breaker
(with over-load pretection)
F.
Fuse
G.
Power supply terminal bed
H.
Control cable terminal bed
- 91 -
15
11 12
H
13 14
(3) LCD remote controller.
(3)-1. Confirmation of parts
The following parts are contained in the carton box together with this manual.
Please check to make sure that everything is included.
Q'TY
1 Remote controller (upper case, lower case) ······································· 1
2 Pan-head screw with cross hole M4 ··················································· 2
3 Wooden screw 4.1 ✕ 16 (for installing unit directly on a wall) ············· 2
4 Instruction manual ················································································ 1
(3)-2. Outline and inside drawing
Refer to (3)-5
Refer to (3)-4
INT / EXT
JH
1 2 3 4
ON
DIP SW
24VAC(N)
24VAC(L)
COMP2 FAN HI
COMP1 FAN LO
4W V
TB1
ERROR
EXT
TB2
SENSOR
Outline (Key cover open)
Controller board
(3)-3. Installation
(1) Decide where you want to install the LCD remote controller (switch box)
In deciding, please observe the following precautions:
Do not install the LCD remote controller in locations, which are:
Exposed to direct sunlight.
Susceptible to humidity and moisture.
Near a source of heat.
Near machines emitting high-frequency waves. (High-frequency welders, etc.)
1) Procure the following parts locally :
Switch box for two units
Connecting wire (Length : below 20m size : 0.75mm2)
Lock nut, bushing
(2) Install the lower case on the switch box.
Connecting wire
Pan-head screws
with cross holes
Switch box for
two units
Connect to terminal
When installing
on switch box
Seal the wire lead-in hole completely with putty
Caution :
Over-tightening the screws can cause deformation and / or cracks on the lower case.
Install the LCD remote controller on a wall with flat surface.
Installation on an uneven surface can cause cracks on the LCD and other failure.
Snap the upper case into place.
Hook the two upper claws into their slots, and shut
the lower part as shown in the right diagram.
Caution :
Press the case until it snaps shut.
To use, remove the protective sheet on the operation section.
To remove the upper case, insert a screwdriver(-)
into one of the slots and slide it in the direction
of the arrow shown in the diagram on the right.
Caution :
Do not turn the screwdriver while it is inserted into the slot.
Doing so can result in damage to the slot.
- 92 -
Refer to (3)-3
(3)-4. Wiring
(1) Connect the wires on the basis of the following wiring diagram.
(2) Connecting work is different each models.
(3) LCD remote controller cables must be installed away from the power cables so that they are not influenced by electrical noise
from the power cables. (Do not place the LCD remote controller cables and power cables in the same conduit.)
Caution : This controller is damaged if mistook the connection.
PE-15,20
2
TB4
3
C03
3
3
FZ
CZ1
3
GRAY
5
PEH-15,20
2
CZ1
C03
3
4
FZ
3
GRAY
3
FAN HI
4WV
AC
24V
Tr
PAC-204RC
COMP2
FAN HI
3
HZ
TB3 1
F2
(3.15A)
C03 C04
1
1
24VAC(N)
24VAC(L)
TB4
3
C03
1
PAC-204RC
COMP1
24VAC(N)
AC
24V
Tr
GRAY
TB4 1
F2
(3.15A)
C03 C04
1
1
4WV
GRAY
3
4
FZ
GRAY
PEH-5,7,8,10
C03
3
FAN HI
24VAC(L)
3
TB3 2
CZ CZ
1-1 1-2
3
4
C03
1
PAC-204RC
COMP2
COMP1
AC
24V
Tr
24VAC(L)
3
TB3 1
F2
(3.15A)
C03 C04
1
1
COMP1
C03
3
C03
1
PAC-204RC
COMP1
AC
24V
Tr
24VAC(L)
F2
(3.15A)
C03 C04
1
1
24VAC(N)
C03
1
GRAY
TB4 1
FAN HI
GRAY
24VAC(N)
PE-7,8,10
3
4
5
TB3 2
CZ CZ HZ1 FZ
1-1 1-2
GRAY
5
6
(3)-5. Setting DIP switch
Set the DIP switches on the basis of the below table.
DIP Switch 1
OFF
ON
DIP Switch 2
ON
OFF
DIP Switch 3
ON
OFF
DIP Switch 4
ON
OFF
Factory pre setting
PE setting
PEH setting
FUNCTION
Mode select
Fan speed
Hi / Lo (*1)
(Not change)
(Change)
Heat pump
(Not change)
(Not change)
(*2)
(Not change)
(*3)
(*3)
Cooling only
Do not change DIP switch 2.
Auto chang
over function (*2)
Available
Auto start at
Power failure (*3)
Not Available
Not Available Automatically
Note. *1: This function can not use at above models, because the fan speed of these models is constant.
*2: If need this function, please consult your local MITSUBISHI ELECTRIC SALES office for application advice on this function.
*3: This function can change by customer self.
If this function use, The unit will auto start at power supply come back after power failure.
- 93 -
(3)-5. How to connect the external sensor (PAC-SE40TSA) to LCD remote controller.
This controller is set for using internal sensor.
If you need the external sensor, please consult your dealer and purchase option external sensor.
(PAC-SE40TSA)
And please change below method.
Shunt jumper
Shunt jumper
1. Remove the cover of LCD remote controller.
2. Connect the wire of external sensor to terminal as
below.
3. Replace the shunt jumper from "INT" side to "EXT" side
as below.
Section A
4. Check above connection. (Refer to PAC-SE40TSA
Installation manual.)
Replace JH (Shunt jumper) from
INT side to EXT side.
5. Attach the cover of LCD remote controller.
Printed board
INT / EXT
JH
COMP2
COMP1
4W V
ERROR
24VAC (N)
24VAC (L)
FAN HI
FAN LO
Detail section A
EXT SENSOR
Cover
Wiring of external sensor
Wiring of
LCD remote controller
LCD remote controller inside
Wiring of LCD remote controller
Wiring external sensor
External sensor PAC-SE40TSA
(4) Wiring example (For metal piping)
Breaker
capacity
Power
cable
Over current
protection switch
Earth cable
2.0mm
15A
15A
2.0mm over
2.0mm
2
15A
15A
2.0mm over
2.0mm
2
15A
15A
PE(H) -10 2.0mm 2
15A
15A
PEH - 5
PE(H) - 7
Control
wiring
2
2
2
PE(H) -15
2.0mm
2
30A
30A
2.0mm over Cable or
wire of 2
2
2.0mm over 0.75mm
(24VDC)
2
2.0mm over
PE(H) -20
2.0mm 2
30A
30A
2.0mm over
PUH - 5
8mm 2
50A
50A
8mm over
8mm
2
50A
50A
8mm
2
50A
50A
60A
60A
The grounding wire must be of the same
Cable or diameter as the power cable wires.
wire of 2
0.75mm Table above is an example.
2
14mm over
(24VDC) The selection of other capacities should be
2
determined in accordance with the relevant
14mm over
standards.
2
22mm over
PE(H) - 8
PU(H) - 7
PU(H) - 8
PU(H) -10 14mm
2
14mm
2
100A
100A
PU(H) -20 22mm
2
125A
125A
PU(H) -15
2
2
2
2
8mm over
2
8mm over
(5) Selecting earth leakage breaker (NV)
To select NF or NV instead of a combination of Class B fuse switch use the following.
In the case of Class B fuse rated 15A.
Fuse
(class B)
Earth leakage breaker
(with over-load protection)
PEH - 5
15A
NV30-CA
15A
30mA 0.1s or less
PE(H) - 7
15A
NV30-CA
15A
30mA 0.1s or less
PE(H) - 8
15A
NV30-CA
15A
30mA 0.1s or less
PE(H) - 10
15A
NV30-CA
15A
30mA 0.1s or less
PE(H) -15
PE(H) -20
30A
30A
NV50-CP
NV50-CP
30A
30A
30mA 0.1s or less
30mA 0.1s or less
PUH - 5
50A
NV50-CA
50A
100mA 0.1s or less
PU(H) - 7
PU(H) - 8
50A
50A
NV50-CA
NV50-CA
50A
50A
100mA 0.1s or less
100mA 0.1s or less
PU(H) - 10
60A
NV60-CA
60A
100mA 0.1s or less
PU(H) - 15
PU(H) - 20
100A
125A
NV100-CP 100A 100mA 0.1s or less
NV225-CP 125A 100mA 0.1s or less
- 94 -
NV is a product of MITSUBISHI
ELECTRIC.
Table above is an example. The
selection of other capacities
should be determined in
accordance with the relevant
standards.
Note.
All electrical wiring must be comply
with local electrical authority
regulations.
7. The putting condition of the belt
(PE(H)-15,20 only)
1. Set the parallel angle of the fan and the motor pulley as shown in the table and figure 1 below.
2. Set the tension of the per one belt when the flexion load is within the range as shown in the figure 1
below at the proper flexion. (A=4.5mm)
3. Adjust the suitable tension after the belt sit properly across the pulley (after more 24-28 hours working).
When the new belt is used, adjust the suitable tension about the 1.3 times of the maximum value of the
flexion load.
4. Readjust the belt every 2,000 hours after the first adjustment.
Exchange the belt when the belt's surroundings length has expanded by 2% including the first expansion
of the belt. (about 1%)
(about 8,000 hours converted working time)
table
parallel angle
pulley
pulley
K( )
note
10 or less
gap of 3mm every 1m
K
Flexion load(W)
1.4 2.2kg
K
K
A
A=4.5mm
K
K
Figure1 Parallel degree of pulley
Figure2 Belt tension
8. Before starting the Trial run
Check items
(1) Check to see wheter there are refrigerant leakage, and slack power or transmission cable.
(2) Conform that 500V megohmmeter shows 1.0M ohm or more between power supply terminal and ground.
(3) Do not operate in the case of 1.0M ohm or less.
Note : Never carry out megger-ohm check over terminal control board.
Otherwise the control board would be broken.
(4) Check to see wheter both gas and liquid valves are fully opened.
Note : Be sure to tighten caps.
(5) Turn universal power supply at least 6 hours before gettig test run in order to current to crank heater.
If current-carrying hours are too short, it may result in a malfunction of compressor.
(6) Confirm operation of high-pressure switch.
If the two lead wires of the outdoor unit fan motor are disconnected from the connector and cooling is
performed, the high-pressure switch should operate and stop the unit after 5 to 10 minutes.
(7) Confirm that the fans of the indoor and outdoor unit rotate in the correct direction.
Change the power supply phase connections if it is rotating in the reverse direction.
Perform trial operation after completion of the above items.
- 95 -
INSTRUCTIONS FOR USE
1. Check points for operation
Check the following points before you operate your air conditioner.
(1)Check that there is nothing blocking the flow of air from the air outlet into the air inlet.
Indoor unit
Inlet grille
Outlet grille
Ceiling
Ceiling
Obstacle blocking air inlet
Obstacle blocking air outlet
Outdoor unit
Obstacle blocking air inlet.
(2)Make sure the air conditioner is properly grounded by checking the ground terminal.
Ground
- 96 -
2. Caution for use
Keep the following points in mind to safeguard against failures and breakdowns.
(1) This air conditioner does not restart within 3min. after shut
down.(These models have a crankcase heater in the
compressor. If the air conditioner is shut down for a short
time, please do not turn the power switch to OFF, but turn
the operation switch to OFF.)
(2) If the air conditioner is shut down by a power failure, set the
operation switch to OFF. When the poweris estored, normal
air conditioner operation can be resumed.
(3) Do not insert a finger or rod into the air outlet and inlet.
It can cause injury as the fan inside is rotating at high
speed.
3 Minutes
Operation
Shutdown
3. Maintenance
For superior performance and lasting durability, please do not forget to conduct
proper and regular maintenance
Warning
.
1.Do not wash the unit with water.
If washed with water, electrical shock may be caused.
2.Ahead of the maintenance.
For safety, turn the power source off before service work.
3.1 Cleaning the Air Filter
Clean the air filter about once a week with a neutral cleanser and leave it to dry in a shady location.
Clean more regularly if the air filter gets very dirty.
If the filter gets blocked, air will not be sucked in properly, and the cooling effect will deteriorate.
Failure to clean the air filter may result in equipment breakdown or malfunctions.
1. Removing the air filter.
2. The air filter is cleaned with the cleaner or washed in clear water.
When the filter is dirty, please wash it with lukewarm water and some neutral detergent is recommended.
Please do not use a hot water of 50˚C or more.
(It transforms occasionally.)
It is necessary to avoid massage washing and squeeze strongly.
It must rinse enough and the detergent must not remain.
3. When the filter is washed in clear water, it is often dried in the shade.
Please do not dry it to direct sunshine and a direct fire.
Shaded
location
Neutral
Cleanser
4. The air filter is installed as before.
3.2 Cleaning panels
Clean dirt off front panel as follows.
Use a household neutral cleanser such as for dishes or
vegetables. Moisten a soft cloth with the cleanser, then wipe
lightly. Next,wipe three or four times with another soft cloth
moisten with water. Finally, wipe off all the remaining
cleanser with a soft cloth.
Moisten a soft cloth with the alcohol, then wipe off lightly.
Isopropyl alcohol is sold at stores as reagents in small quantities.
Note:
Alcohol is highly combustible. Take extreme care when handling.
Also, do not use paint or adhesive thinner.
- 97 -
Fingermarks
Grease
Adhesive
Paste
Neutral
Cleanser
Isopropyl
alcohol
3.3 Cleaning the Outdoor Unit Heat Exchanger
If you use your air conditioner for prolonged periods,
the outdoor heat exchanger will become dirty, impairing
its function and reducing air conditioners performance.
Consult your equipment supplier or air conditioning
contractor on how to clean the heat exchanger.
Heat
exchanger
4. The putting adjustment of the belt (PE(H)-15,20 only)
The tension of the belt decrease with the passage of the drive time by total length's expands.
Under such a condition, it occasionally causes the breakdown by a strange wear and an abnormal sound if it keeps
driving.
Please have seeing installed manual or consult your dealer about details of the adjustment of V pulley.
Adjustment time
4.5mm
First time:
24 ~ 28 hours later
Since the second times: Every 2000 hours later
Exchange:
Every 8000 hours later
V pulley
Flexion load (W)
1.4 kg 2.2kg
5. When beginning to use air conditioner again
Please turn on the power supply after confirming an following check is done and abnormality is not found.
It is confirmed that air inlet and outlet are not blocked.
It is confirmed that the earth connection line does not come off.
The earth connection line is installed surely in the unit.
It is confirmed that there are neither lifting, blocking, no bending about the drain-hose.
Please do the following work.
1. It is confirmed to keep the controller OFF.
2. The power supply switch is turned on.
Keep the power switch ON for more than 6 hours before starting operation.
Do not turn the power supply OFF during seasons of heavy use, doing so can result in failure.
6. When the air conditioner is not to be used for long time
If the air conditioner is not to be used for a long time due to a seasonal change, etc.,
Please do the following work.
1. The power supply switch is turned off.
If the power supply is kept on, several watts or several tends of watts will be wasted.
Also, the accumulation of dust, etc., can result in fire.
2. Filter and drain pan are cleaned.
Pay attention to throw dust in the drain.
3. Run it for 4-5 hours with the air blowing until the inside is completely dry.
Failing to do so can result the growth of unhygienic, unhealthy mold in scattered areas throughout the room.
7. In case of failure
1. Never remodel the air conditioner.
Consult your dealer for any repair service.
Improper repair work can result in water leakage, electric shock, fire, etc.
2. If the poser breaker is frequently activated, get in touch with your dealer.
Leaving the unit as it is under such conditions can result in fire or failure.
3. If the refrigeration gas blows out or leaks, stop the operation of the air conditioner.
4. Thoroughly ventilate the room, and contact your dealer.
Leaving the unit as it is can result in accidents due to oxygen deficiency.
- 98 -
8. Transferring work, and construction
8.1 Transfer of installation
1. When removing and reinstalling the air conditioner when you enlarge your home, remodel, or move, consult with
your dealer in advance to ascertain the cost of the professional engineering work required for transferring the
installation.
2. Please do not mix the one other than a specified refrigerant when you add the refrigerant (R-22) at the installation
and the transferring.
3. When moving or reinstalling the air conditioner, consult with your dealer.
Defective installation can result in electric shock, fire, etc.
8.2 Place for installation.
Please do not use the unit in the following places.
1. Place where a lot of oil (The machine oil is contained), moistures, and dust exist.
2. Place where a lot of salinities such as beach districts exists.
3. Place where sulfur gas, volatile gas, and corroded gas are filled.
4. Place where acid solution is frequently used.
5. Place where special spray is frequently used.
6. Hot spring zone.
7. Never machine (high cycle welding machine etc.) generating high cycle.
8. Place where ventilation entrance of outdoor unit is closed by snowfall.
9. The unit must be installed on stable, level surface.
The main body might corrode when the unit is used in such a place, the refrigerant leak, the performance of the unit
decrease remarkably, and it cause the damage of parts of the unit.
8.3 Regarding electric work
1. The electrical work must be undertaken by a person who is qualified as an electric engineer according to the
(technical standard respecting electrical installation), (internal wiring rules), the installation and operation manual
with the absolute use of exclusive circuits. The range of working voltage is within ±10% voltage of power supply.
2. Please install a special power supply in the power supply.
3. Please install the earth connection for the electric shock prevention.
4. Never connect the grounding wire to a gas pipe, water pipe, arrester, or telephone grounding wires.
For details, consult with your dealer.
5. In some types of installation sites, the installation of an earth leakage breaker is mandatory. For details, consult
with your dealer.
6. The breaker and the fuse must use the one of correct capacity.
8.4 Consideration of the noise
1. Take sufficient measures against noise when installing the air conditioners at hospitals or communication-related
businesses.
2. If the air conditioner is used in any of the above-mentioned environments, frequent operational failure can be
excepted.
It is advisable to avoid these type of installation sites.
For further details, consult with your dealer.
3. Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner do not
inconvenience the neighbours.
4. If any obstruction is placed near the air outlet of the unit, decreased performance and increased noise can result.
Do not place any obstruction near the air outlet.
5. If the air conditioner produces any abnormal sound, consult with your dealer.
8.5 Disposing of the unit
When you need to dispose of the unit, consult your dealer.
If pipes are removed incorrectly, refrigerant (fluorocarbon gas) may blow out and come into contact with your
skin, causing injury.
Releasing refrigerant into the atmosphere also damages the environments.
8.6 Maintenance and inspection
1. If the air conditioner is used throughout several seasons, the insides can get dirty, reducing the performance.
2. Depending upon the conditions of usage, foul odours can be generated and drainage can deteriorate due to dust
and dirt, etc.
- 99 -
9. Troubleshooting
Before you ask for repair service, check the following points:
State of Machine
It does not run.
Cause
LCD remote controller
“ON-OFF” display is
not lit up.
No display appears
even when the [ON/
OFF] button is
pressed.
Troubleshooting
Power failure.
Press the [ON/OFF] button after power restoration.
The power supply is turned OFF.
Turn the power supply ON.
The fuse in the power supply is gone.
Replace fuse.
The earth leakage breaker is gone.
Put in the earth leakage breaker.
The wiring phase of power supply is mistaken. Modify the wiring phase of power supply.
Air flows out but
it does not cool or
heat enough.
The liquid crystal
display shows that
it is in the state of
operation.
Improper temperature adjustment.
After checking the set temperature and inlet
temperature on the liquid crystal display, refer to
[To change room temperature] on page 7, and
operate the adjustment button.
The filter is filled with dust and dirt.
Clean up the filter.
There are some obstacles at the air inlet and
outlet of the units.
Remove.
Windows and doors are open.
Close.
Insufficient refrigerant charge.
Contact with your installing contractor.
Cool or warm air
does not come out.
The liquid crystal
display shows that
it is in operation.
The restart-preventing circuit is in operation for Wait for a while.
3 minutes.
(To protect the compressor, a 3-minute restartpreventing circuit is built into the unit.
Therefore, there are occasions sometimes when
the compressor does not start running immediately.
There are cases when it does not run for as long
as 3 minutes.)
Can not change to
Heat mode.
(PEH only)
Can not change to
Heat mode when
press the “MODE” key.
DIP switch 1 is not correct.
Change the DIP switch off to on.
(Refer to Installation manual.)
On heating, cool air comes out. (PEH only)
Indoor unit operation shift to defrost.
Wait for a while.
(Heating operation starts after ending defrosting
operation.)
Fan runs but compressor do not run.
The set temperature of thermostat is
excessively high for cooling.
excessively low for heating. (PEH only)
For temperature control,
decrease the set temperature at cooling.
increase the set temperature at heating. (PEH only)
The room temperature is
excessively low for cooling.
excessively high for heating. (PEH only)
Can not be operated as it is out of temperature
control range.
Fan runs but stops immediately.
Air outlet and inlet are blocked.
Remove blocking matter.
Fogged white steam is discharged from
the indoor unit.
When the indoor temperature and humidity are
high, such a phenomenon is occasionally had
at the beginning of system operation.
It is not a breakdown.
Please use as it is.
Water or steam is discharged from the
outdoor unit.
At cooling, water which places to cooling piping
and piping connection part drops.
When heating, water which places to the heat
exchanger drops. (PEH only)
It is not a breakdown.
Please contact and consult your dealer.
The drain pipe is clogged due to dust, therefore
the drain water overflow.
On heating, the air flow stops although a set
temperature is not reached. (PEH only)
Frost adheres to the outdoor coil when the
temperature on the outside is low and humidity
is high. This frost is melted.
It is not a breakdown.
Please use as it is.
LCD remote controller error display
Indicate
Cause
Troubleshooting
E01
Room temperature sensor open.
Automatically reset to restoration error.
E02
Room temperature sensor short.
Automatically reset to restoration error.
E03
Error input from Indoor unit or
Outdoor unit.
Push the On-Off switch. (OFF to ON)
- 100 -
HOW TO OPERATE
If you use the LCD remote controller, you can operate below method.
Please consult operate method with dealer, if you use field supply control parts.
Display section
C
1. ON / OFF
G
B
E
H
D F
A
J
1
E
E
Operation lamp
Start an operation
Press the [ON/OFF] button
1
Operation lamp lights up and operation starts.
For purposes of explanation, all the displays on this page are shown
in their lit condition. This configuration does not occur in the actual
unit.
Before starting operation
* Make sure that the power supply is turned ON before use.
(Keep the power supply turned ON at all times when the air conditioner
is in use. Use of the unit without power can result in compressor failure.)
Stop an operation
Press the [ON/OFF] button
A
[Current/start/ending time] Display
B
Operation mode
Displays the status of operation.
C
[Checking] Display
This displays indication when some abnormality occurs in the unit.
D
[Set temperature] Display
Displays the set temperature.
E
[Operation] Lamp
Lights up during operation, goes off during stop.
F
[Room temperature] Display
Displays the temperature of the air sucked in during operation.
G
[Fan speed] Display
This displays indication High-speed or Low-speed.
H
[Key lock] Display
This display indication during key lock function active.
J
[Timer Hold / Resume setting] Display
- 101 -
again
* Once the buttons have been set, pressing of the [ON/OFF] button
only can repeat the same operation thereafter.
* During operation, the operation lamp above the [ON/OFF] button
lights up.
Caution:
Warning:
Check and confirm the power circuit before use. For the contents, refer to
the previously described chapter [Crucial points to be observed for safety].
1
Operation lamp goes off and operation stops.
Even if the operation button is pressed immediately after the
operation is once stopped, operation is not restarted for about
3 minutes.
This function protects the machine. It automatically starts
operation after the lapse of approximately 3 minutes.
2. Selecting operation
3. Room temperature adjustment
B
D F
2
B
3
Operation mode display
D
When selecting operation
Press the [MODE] button
Set temperature display and F room temperature display
To change room temperature
2
Consecutive press of the [MODE] button switches the operation over
to “FAN”, “COOL”, “HEAT” and “AUTO”.
For the contents of operation, check the display.
For fan
Press the [MODE] button 2 and bring up the “FAN” display.
* The fan operation functions to circulate the air in the room.
* The temperature of the room cannot be set by fan operation.
Press the [SET TEMP] button
temperature of your choice.
3
and set the room
Press
or
button once changes the setting
by 1˚C. If the pressing is continued, the setting continues
to change by 1˚C.
* Indoor temperature can be set within the following
range.
Cooling
19 ~ 30 ˚C
Heating
17 ~ 28 ˚C (PEH only)
Caution:
Never expose your body directly to cool air for a long time.
Excessive exposure to cool air is bad for your health, and
should therefore be avoided.
For cooling
Press the [MODE] button
2
and bring up the “COOL” display.
2
and bring up the “HEAT” display.
For heating (PEH only)
Press the [MODE] button
Caution:
* When the air conditioner is used together with burners,
thoroughly ventilate the area. Insufficient ventilation can
result in accidents due to oxygen deficiency.
* Never place a burner at a place where it is exposed to the
airflow from the air conditioner.
Doing so can result in imperfect combustion of the burner.
For Auto change over
(PEH only)
Press the [MODE] button 2 and bring up the “AUTO” display.
This function is special order. Please consult your local
Mitsubishi Electric Sales office for application advice on this
function.
Because this function need low ambient cooling parts as
option.
Indoor temperature can be set within the following range.
Indoor temperature setting range : 17 ~ 30 ˚C
- 102 -
* It is impossible to set the room temperature by the
air-blow operation.
Press
and
button together, the unit of
temperature change “˚C ” (degree-centigrade) and “˚F ”.
(degree-Fahrenheit)
4. Time setting
5. Other function
A
H
J
5
1
8
9
5
10
4
A
J
7
7
6
Current time display
Timer Hold/Resume display
11
Key lock
Press the [MINUTE] button 7 three times
consecutively, the word “KEY LOCK” will
displayed H .
At this time, only [ON-OFF] button 1 is valid.
This function purpose is protect from mischief
of child etc.
Clock setting
Press the [CLOCK] key 4 one time will activate set clock mode.
Press the [CLOCK] key 4 again will disable set clock mode.
Under set clock mode, the real time clock and present day
setting can be changed by pressing [DAY] button 5 , [HOUR]
button 6 or [MINUTE] button 7 .
To cancel the key lock function, Please press
[MINUTE] button 7 three times consecutively
again.
Caution:
[CLOCK]
key 4 is not allowed to be pushed with the thing of sharp tip.
Test run
7-Days timer setting
Press the [TEST] button 11 two times consecutively.
The unit will run and finished automatically after
two hours.
There are two buttons for timer. One is [ON TIMER] 8 , another is
[OFF TIMER] 9 .
Press the button one time will activate set timer mode.
Press the same button again will disable set timer mode.
Under set timer mode, the 7-days timer setting can be changed
by pressing [DAY] button 5 , [HOUR] button 6 or [MINUTE]
button 7 .
Day setting
During set clock mode or set timer mode, press the [DAY] button
will change the day setting.
5
Hour setting
During set clock mode or set timer mode, press the [HOUR] button
will change the hour setting.
Minute setting
During set clock mode or set timer mode, press the [MINUTE]
button 7 will change the minute setting.
Timer Hold / Resume setting
If 7-days timer is set, then the word “Timer Active” is displayed J .
To clear all the timers setting, press and hold the [HOLD] button 10
until the word “Timer Active” is not displayed.
To resume the timer setting after timers have been held, press
and hold the [HOLD] button 10 until the word “Timer Active” is
displayed.
- 103 -
6
LOW AMBIENT COOLING PARTS; OPTION PAC-205FC (Fan controller)
1. Outline
This fan controller apply to following units.
Model name
Model name
Q'TY
PUH-5,8,10 (side blow)
Q'TY
PUH-15,20
PUH-7,8,10 (upper blow)
2 set
1 set
PU-7,8,10
These units can be operated on cooling mode at the low ambient temperature with this optional FAN CONTROLLER.
Please read carefully this manual and install following this.
2. Caution
1. Fan controller changes the outdoor fan speed.
Strong wind is injurious to fan speed controller.
Please install the windproof when unit is influenced by strong wind such as install it on the place there is no building
in surrounding or the rooftop
2. As the case may be the operation with FAN CONTROLLER generate an electromagnetic sound from fan motor.
Please consider the soundproofing wall equipment etc. when using the fan controller in the place where the noise
becomes a problem.
There is no worry which interferes to the unit though an electromagnetic sound might be generated from fan motor.
3. When shipping the fan controller, the dip switch on the control circuit board is set as follows.
Do not change factory set of all dip switches.
ON
SW2
ON
Only SW3 direction is different.
SW3
ON
ON
SW1 SW2
SW1
SW0
SW0
SW3
1
2
3
4
1
(3,4 ON)
2
3
4
(All OFF)
1
2
3
4
(1,3 ON)
1
2
3
4
5
6
7
8
(1,3,4,5,6 ON)
Control circuit board
Fan controller inside
3. Parts
There are the following parts in this box, and confirm whether there are all attached.
There are two kinds of wiring sticker in this box.
Accessory assy 1
Please select the pertinent one by model name.
Accessory assy 2
Installation manual
(This manual)
Fan controller
Accessory assy 1
Name
Wiring sticker
Screw
Connector cap
Spring
Earth sticker
Grommet
2
12
1
1
1
2
Pipe cover
Band
Connector assy
3
15
1
Shape
Amount
Accessory assy 2
Name
Attachment
Attachment
Attachment
Shape
Amount
1
1
3
- 104 -
4. Installation
4-1. PU(H)-7,8,10
Please use the following parts during installation of fan controller.
There are two kinds of wiring sticker, please use writing as "ONLY PU(H)-7,8,10".
Accessory assy 1
Wiring sticker
Use
Accessory assy 2
Spring
Connector cap
Screw
Earth sticker
Attachment
Grommet
Band
Pipe cover
Connector assy
ONLY PU(H)-7,8,10
9
1
Accessory assy 1
Wiring sticker
Screw
1
1
Accessory assy 2
Attachment
Attachment
1
2
3
3
15
1
Not
use
3
1
1
1
4-1-1. Install
4-1-2. Wiring
1. The service panel and control box
cover are removed.
1. The wiring from the printed circuit board CN04 is pulled out.
(In case of PU-7,8,10 only)
Control box cover
Service panel
Fan
controller
2. Penetrate the knockout holes at
Grommet
the pillar L.
The grommet (2 pieces)
install to the hole for wiring
in the pillar L.
Wiring hole
pull out
CN04
Fan controller inside
Pillar L
Install to
the top panel.
(Screw 2 pieces)
3. The attachment (3 pieces)
install to the unit with the
screw (6 pieces).
2. Disconnect connector C11 - C11 and C21 - C21.
The connector C11 and C21 remove to the
motor side and the control box side.
MF2
Control box
C11
C21
C11
C21
F/C
Install to
the pillar L.
(Screw 1 piece)
Attachment
4. Wiring from the fan controller is passed through the hole of procedure 2.
The thermistor and other wiring should use separate wiring hole.
The fan controller install to the attachments with the screw (3 pieces).
Thermistor wiring
Other wiring
only
3. Cover the connector C11 (control box side) is cap with the connector cap
The connector assy connect as shown in the figure below.
When it is connected, the connector is connected in the control box.
The wiring from CN04 connect to the terminal block (F/C, N)
in the control box. (In case of PUH-7,8,10 only)
MF3
Connector assy
Control box
Fan
controller
C11
C21
C11
C21
Other wiring
5. Confirm the thermistor holder position.
The spring insert in the thermistor holder.
The thermistor (black wiring) which is connected to the fan controller
is put in the holder.
Thermistor
Accumulator
Thermistor
holder position
Compressor
Thermistor position
6. Please use the pipe cover
The thermistor wiring is
bundled as follows before
the pipe cover is installed.
Fan controller
Terminal
block
F/C
N
This wiring is
PUH-7,8,10 only.
CN04
U V W
L1 L2 L3
Connector cap
Please be careful, do not damage wires by the sheet metal edges or the fin, etc.
4. After connect wiring, to prevent wiring being damaged with the fin,
the pipe cover (2 pieces) and band (4 pieces) are used.
In that time, never bundle the thermistor wiring with other wiring.
Thermistor holder
Spring
Insert the thermistor
(1 piece) and fix with the band
Pipe cover
Thermistor
wiring only
(2 pieces).
Band
Other wiring
Fan
controller
Band
Pipe cover
Thermistor
wiring only
Other wiring
Pipe
Comp cover
7. The earth sticker and wiring sticker are put on the following place.
1. The earth sticker is put on the top panel.
2. The wiring sticker is put on the control box cover (inside).
Fan controller
wiring sticker
Earth sticker
Control box
Pillar L
Control box
cover
Fan
controller
Put a earth sticker
N
Terminal block
MF2
Thermistor wiring
only
MF3
Unit wiring
sticker
5. After wiring ends, the wiring is bundled with a remaining band.
Never bundle the thermistor and other wiring together.
6. Ensure there is not wiring mistake found, then only install the controller
box cover and service panel.
Put a wiring sticker
- 105 -
.
4-2. PUH-15,20
Please use the following parts during installation of fan controller. There are two kinds of wiring sticker, please use
writing as "W881927".
The fan controller is necessary for these models by two sets.
(The following accessory parts show the fan controller one set.)
Accessory assy 1
Wiring sticker
Spring
Screw
Accessory assy 2
Earth sticker
Grommet
Attachment
Pipe cover
Band
Use
1
Wiring sticker
Not
use
5
1
Accessory assy 1
Screw
Connector
1
2
1
Accessory assy 2
Attachment Connector assy
Attachment
3
15
ONLY PU(H)-7,8,10
1
7
1
1
3
4-2-1. Install
1
4-2-2. Wiring
1. The service panel and control box
cover are removed.
Control box
cover
1. The wiring from the printed circuit board CN04 is pulled out.
(In case of PR-15,20 only)
Service panel
2. Penetrate the knockout holes at
Grommet
the top panel.
The grommet (2x2 pieces)
install to the hole for wiring
in the top panel.
Wiring hole
3. The attachment (2x1 pieces)
install to the pillar 2 with the
screw (2x2 pieces).
pull out
Fan controller
CN04
Fan controller inside
2. Disconnect connector C11 - C11 and C21 - C21.
The connector C11 and C21 remove to the
motor side and the control box side.
Install to the pillar 2.
(Screw 2x2 pieces)
MF2
MF3
Control box
C11
C21
C11
C21
F/C
N
Attachment
Terminal block
4. Wiring from the fan controller is passed through the hole of procedure 2.
The thermistor and other wiring should use separate wiring hole.
The fan controller install to the attachments with the screw (2x1 pieces)
and install to the top panel with the screw (2x2 pieces).
Install to the top panel.
(Screw 2 pieces)
Thermistor wiring
only
3. When the fan controller is installed, the connector is connected in the
control box.
The wiring from CN04 connect to the terminal block (F/C, N) in the control
box. (In case of PUH-15,20)
Other wiring
MF2
MF3
Terminal block
Control box
Fan
controller
C11
Thermistor wiring
only
Install to the top panel.
(Screw 2 pieces)
Other wiring
C11
Fan controller
Fan controller
C21
C21
F/C
N
This wiring is
PUH-15,20
only.
CN04
U V W
L1 L2 L3
CN04
U V W
L1 L2 L3
Fan controller
5. Confirm the thermistor holder position. (2 places)
The spring (2x1 pieces) insert in the thermistor holder.
The thermistor (black wiring) which is connected to the fan controller
is put in the holder.
Please be careful, do not damage wires by the sheet metal edges or the fin, etc.
Thermistor
Thermistor holder
4. After connect wiring, to prevent wiring being damaged with the fin,
the pipe cover (2x2 pieces) and band (2x4 pieces) are used.
In that time, never bundle the thermistor wiring with other wiring.
Thermistor
holder position
Compressor
Spring
Thermistor position
6. Please use the pipe cover
(2x2 pieces).
The thermistor wiring is
bundled as follows before
the pipe cover is installed.
Top panel
Control box
Insert the thermistor
(2x1 pieces) and fix with the band
Pipe cover
Thermistor
wiring only
Other wiring
Thermistor
wiring only
Other wiring
Band
Band
Pipe cover
Fan controller
Thermistor
wiring only
Pipe
7. The earth sticker and wiring sticker are put on an following place.
1. The earth sticker (2x1 pieces) is put on the top panel.
2. The wiring sticker (1 piece) is put on the control box cover (inside).
Earth sticker
5. After wiring ends, the wiring is bundled with a remaining band.
Never bundle the thermistor and other wiring together.
6. Ensure there is not wiring mistake found, then only install the controller
box cover and service panel.
Fan controller
wiring sticker
Unit wiring sticker
Fan
controller
Put a earth sticker
Put a wiring sticker
Other wiring
- 106 -
4-3. PUH-5,8,10 (Side blow type)
Please use the following parts during installation of fan controller.
There are two kinds of wiring sticker, please use writing as "W881927".
Accessory assy 1
Wiring sticker
Spring
Screw
Accessory assy 2
Earth sticker
Grommet
Pipe cover
Band
Use
1
Wiring sticker
Not
use
3
1
Accessory assy 1
Screw
Connector
1
2
3
Accessory assy 2
Attachment
Attachment
Attachment
15
Connector assy
ONLY PU(H)-7,8,10
1
9
1
1
4-3-1. Install
1
4-3-2. Wiring
Control box
cover
1. The service panel and control box
cover are removed.
3
1
1. Disconnect connector C11- C11.
The connector C11 removes to the motor side
and the control box side.
Service panel
MF2
Control box
C11
C11
51
Grommet
2. Penetrate the knockout holes at
the pillar 3.
The grommet (2 pieces) install to
the hole for wiring in the pillar 3.
Terminal block
2. When the fan controller is installed, the connector is connected in the
control box.
The wiring from CN04 connect to the terminal block (F/C, N) in the control
box.
Wiring hole
Pillar 3
MF2
3. Wiring from the fan controller is passed through the hole of procedure 2.
The thermistor and other wiring should use separate wiring hole.
The fan controller install to the pillar 3 with the screw (1 piece) and
install to the top panel with the screw (2 pieces).
Control box
Fan controller
C11
Terminal block
C11
Install to the top panel.
(Screw 2 pieces)
F/C
CN04
N
U V W
L1 L2 L3
Thermistor wiring
only
Fan controller
Please be careful, do not damage wires by the sheet metal edges or the fin, etc.
Other wiring
Install to the pillar 3.
(Screw 1 piece)
3. After connect wiring, to prevent wiring being damaged with the pipe
header, the pipe cover (2 pieces) and band (4 pieces) are used.
In that time, never bundle the thermistor wiring with other wiring.
4. Confirm the thermistor holder position.
The spring insert in the thermistor holder.
The thermistor (black wiring) which is connected to the fan controller
is put in the holder.
Thermistor
wiring only
Other wiring
Fan
controller
Thermistor
holder position
Thermistor
Control
box
Thermistor holder
Thermistor
wiring only
Compressor
Accumulator
5. Please use the pipe cover
Pipe cover
(2 pieces).
Band
5. Ensure there is not wiring mistake found, then only install the controller
box cover and service panel.
Pipe
6. The earth sticker and wiring sticker are put on an following place.
1. The earth sticker is put on the pillar 3.
2. The wiring sticker is put on the control box cover (inside).
Unit wiring sticker
Earth sticker
Fan controller
wiring sticker
Fan
controller
Put a earth sticker
Pillar 3
4. After wiring ends, the wiring is bundled with a remaining band.
Never bundle the thermistor and other wiring together.
Insert the thermistor
(1 piece) and fix with the band
Pipe cover
Band
Other wiring
Spring
Thermistor position
The thermistor wiring is
bundled as follows before
the pipe cover is installed.
N
Put a wiring sticker
- 107 -
5. Before starting the trial run.
Please execute the following confirmations to prevent wrong connection.
If there is wrong connection, it may damage fan controller, but also damage the unit.
Confirmation
Please intercept the power supply without fail, and secure safety when you execute detaching wiring, the connector,
and the measurement machine to the following work.
Step
Step 1
Connected
confirmation
Confirmation matter
Check
Correspondence
Step 1-1 Is fan controller's power supply input wiring position connected correctly as
shown in installed manual?
Step 1-2 Is the phase of the connection of fan controller power supply input (TB IN)
accurate?
Step 1-3 Is the phase of the connection of fan controller output (TB OUT) accurate?
Step 1-4 Is the phase of connection of fan controller output wiring to fan motor accurate?
Step 1-5 Is the thermistor for the condensing temperature detection of the attachment
connected with CN01?
Step 1-6 Is the thermistor for the condensing temperature detection accurately installed
in the unit?
Step 1-7 In case of the heat pump model, the wiring for full load input is connected with
CN04?
Step 1-8 In case of the heat pump model, the wiring for full load input is connected
accurately in control box?
Step 2-1 Does the fan rotate in a correct direction, when the unit is driven ?
Step 2
Drive confirmation Step 2-2 The thermistor for the condensing temperature detection is removed to CN01.
Drive to the cooling operation.
(The unit stops abnormally when the cooling operation drive is continued for a
long time occasionally. - High pressure switch off)
Whether LED01 has blinked is confirmed.
When the unit is in operation, the fan controller output voltage measured
in TB OUT, and checked whether the output of about 200V.
There is a problem when it is an output of about 300V.
Troubleshooting 1,2
Troubleshooting 3
Step 2-3 The thermistor for the condensing temperature detection is surely connected
with CN01 as before.
Step 2-4 In case of the heat pump model and the heating drive is possible, the heating
drive is executed and the voltage of CN04 is input AC198V - 264V.
In that case, the fan must be full load drive.
(The output of the power-supply voltage is confirmed in TB OUT. )
When heating cannot be driven, step 1-7, step 1-8 is executed again.
Refer to Step 1-3
TB IN
TB OUT
Refer to Step 1-5
Step 2-2
Step 2-3
CN01 CN04
U
Refer to Step 1-7
Step 2-4
V
W
L1 L2 L3
U : Red
V : White
W : Black
L1 : Red
L2 : White
L3 : Black
Fan controller layout
- 108 -
Refer to Step 1-2
Troubleshooting 4
Cause
Check point
- 109 -
6) The fan motor and unit side control box
are defective.
Fan power supply wiring is connected
with fan controller power supply taking
out part, and confirm operation.
Whether the voltage is input to fan motor is
confirmed.
Whether the fan motor operation is
confirmed.
When the voltage impression and fan motor does
not work, fan motor is defective.
When the voltage is not impressed to the fan, the
unit side control box is defective.
When there is no wrong above-mentioned,
it is assumed fan controller connection state,
if abnormality relapses, the control printing board
is defective and exchange.
At the time of turning off light.
The CN01 connector is removed, and measures
resistance. When the resistance is 25 kilo-ohm or
more, repair the control printing board due to the
thermistor open breakdown.
In case of thermistor is correct, the control
printing board is defective and exchange.
The content of P15 is judgment. (SCRM)
The blinking of LED01 is confirmed.
At the time of turning on light. (always)
After checking item 1)-4), when the power
supply is turned on, the blinking of LED01 is The CN01 connector is removed, and measures
resistance. When the resistance is 1 kilo-ohm or
confirmed.
less, repair the control printing board due to the
thermistor short-circuit breakdown.
In case of thermistor is correct, the control
printing board is defective and exchange.
Replace SCRM when abnormality is found.
Resistance between the lines of primary side Replace the transformer in case of abnormal
resistance.
(red and white) about 310 ohm.
Resistance between the lines of secondary
side (CN02 the connector is removed from
the printing wiring board.)
Between 1-3 pin about 0.9 ohm
CN02- thermistor
TB OUT - fan motor
The wiring mistake is corrected.
The power supply wiring is confirmed,
and corrected.
Troubleshooting
5) The control printing wiring board is
defective.
The resistance is confirmed.
(Between the lines of primary side, and
lines of secondary side.)
The unit side connection is confirmed.
The fan controller connection is confirmed. TB IN-NF wiring
TB IN-T01-CN02.
NF-SCRM-TB OUT
CNU, CNV, CNW-SCRM
(The connection is noted.)
Is the power-supply voltage 342-457V?
Content of confirmation
4) The thyristor module (SCRM) is defective. The content of P15 is checked. (SCRM)
3) The transformer (T01) is defective.
2) Connected mistake
1. The fun does not run. 1) The power-supply voltage is abnormal. The value of power-supply voltage is
confirmed. (TB IN)
State of Machine
Please intercept the power supply without fail, and secure safety when you execute detaching wiring, the connector,
and the measurement machine to the following work.
6. Troubleshooting
- 110 -
State of Machine
Cause
3) Connected mistake
2) Output wiring supply reverse-phase.
1) Power supply reverse-phase.
It becomes highpressure abnormal
pressure.
Something wrong
occurs by step2-2 drive
confirmation of installed
confirmation matter.
Check point
The phase of U, V, W is corrected.
Is the phase of U, V, W correct?
Troubleshooting
The phase of L1, L2,L3 is corrected.
Content of confirmation
Is the phase of L1, L2, L3 correct?
The phase of U, V, W is corrected.
Is the phase of U, V, W correct?
The phase of fan motor output wiring is
confirmed. (TB OUT)
If the position where the thermistor is installed is
wrong, the rotation speed control of the fan as
condensing temperature is impossible.
The connected phase is confirmed.
The wiring mistake is corrected.
When there is an input in CN04, the fan is full load..
TB OUT - fan motor
(The phase (U, V, W) is noted.)
Position of the wiring for full load input
(In heating)
Installation position of thermistor
The content of P14 is judgment. (SCRM)
SCRM exchange when abnormality is found.
The set of dip switch is confirmed. (SW0-3) It is confirmed that the switch setting is
The control substrate is matched to setting the
(P2)
corresponding to the electric wiring diagram. electric wiring diagram.
The unit side connection is confirmed.
When there is a connector connection in CNX,
it is removed.
There must not be connector connection in
CNX.
(CNX is compulsion full load input.
Full load when short-circuited.)
CNU, CNV, CNW-SCRM
(The connection is noted.)
CN02- thermistor
CN04- the wiring for full load input in heating In cooling, when there is an input in CN04, wiring
(CN04 input is AC198-264V in heating.)
of CN04 is mistake connection.
The wiring is corrected.
NF-SCRM-TB OUT (The connection phase is
noted.)
TB IN-T01-CN02 (The connection phase is
noted.)
The connected phase is confirmed.
The wiring mistake is corrected.
The phase of L1, L2,L3 is corrected.
Is the phase of L1, L2, L3 correct?
The phase of input voltage is confirmed.
(TB IN)
The fan controller connection is confirmed. TB IN-NF wiring (The connection phase is
noted.)
During heating drive, there is an input in CN04 and
the fan becomes full load drive.
Normality
Is not AC198-264V input in CN04?
The input voltage is confirmed. (CN04)
CNU, CNV, CNW-SCRM
(The connection is noted.)
The fan controller connection is confirmed. TB IN-NF wiring (The connection phase is noted.) The connected phase is confirmed.
The wiring mistake is corrected.
NF-SCRM-TB OUT (The connection phase
is noted.)
The phase of input voltage is confirmed.
(TB IN)
The phase of fan motor output wiring is
confirmed. (TB OUT)
5) The thyristor module (SCRM) is defective. The content of P14 is checked. (SCRM)
4) The control printing wiring board setting
is defective.
3) Connected mistake
2) Power supply reverse-phase.
Output wiring reverse-phase.
3. The rotation speed 1) During heating drive
of fans cannot control.
2. The fan rotates
oppositely.
- 111 -
4. The fan never
becomes full load
drive. (In heating)
State of Machine
Item 1) is checked, again.
3) The control printing wiring board is
defective.
After checking item 1), there is a
possibility of a defective printed circuit
board if a normal drive is not done.
The content of P14 is judgment. (SCRM)
2) The thyristor module (SCRM) is defective. The content of P14 is checked. (SCRM)
The unit side connection is confirmed.
CNU, CNV, CNW-SCRM
(The connection is noted.)
CN04- the wiring for full load input
(CN04 input is AC198-264V in heating.)
Position of the wiring for full load input
(In heating)
NF-SCRM-TB OUT
TB IN-T01-CN02
The fan controller connection is confirmed. TB IN-NF wiring
1) Connected mistake
After checking item 1)-5), when the power
supply is turned on, the blinking of LED01
is confirmed.
Content of confirmation
The blinking of LED01 is confirmed.
Check point
6) The control printing wiring board is
defective.
Cause
After checking item 1), if there is no problem,
the control printing board is defective and exchange.
Replace SCRM when abnormality is found.
The wiring mistake is corrected.
It is confirmed that wiring is correctly connected.
The wiring mistake is corrected.
At the time of blinking
The item 2), 3) are confirmed again, and there is
no connection mistake, the control printing board
is defective and exchange.
At the time of turning off light
(There is a possibility of the thermistor open
breakdown.)
The CN01 connector is removed, and measures
resistance. When the resistance is 25 kilo-ohm or
more, repair the control printing board due to the
thermistor open breakdown.
In case of thermistor is correct, the control printing
board is defective and exchange.
At the time of turning on light (always)
(There is a possibility of the thermistor short-circuit.)
The CN01 connector is removed, and measures
resistance. When the resistance is 1 kilo-ohm or
less, repair the control printing board due to the
thermistor short-circuit breakdown.
In case of thermistor is correct, the control printing
board is defective and exchange.
Troubleshooting
Thyristor module (SCRM)
<Judgment Method>
Measure the resistance between each of the SCRM pins and judge if there is a failure or not by the
resulting values.
<Judgment Values 1>
Check between G and K.
Use the smallest resistance range on the tester.
Judgment Value: 1.5 ohm
80 ohm
<Judgment Values 2>
Check between AK1 and AK2.
Use the greatest resistance range on the tester.
Judgment Value: 60 kilo-ohm
ohm
<External View>
AK1
AK1
AK1
K
G
K
G
K
G
G
K
G
K
G
K
AK2
AK2
AK2
<Internal Circuit Diagrams>
AK1
AK1
AK1
K
K
K
G
G
G
G
G
K
K
AK2
G
AK2
- 112 -
K
AK2
SPECIFICATION GUIDELINES
Air to air reverse cycle split air conditioning system.
The systems shall operate at out door ambient temperatures as high as __ ºC.
The system shall have a total cooling capacity of __kW or greater with an indoor air quantity of __ L/s at __ ºC DB and
__ ºC WB entering indoor coil temperature with a __ ºC temperature entering the outdoor coil.
The system shall have a sensible heat capacity of
kW or greater with a room DB temperature of __ ºC.
The total heating capacity (without electric element heaters) shall be
conditions, with __ ºC of indoor air entering indoor coil at __ ºC DB.
kW or greater at __ ºC DB, __ ºC WB outdoor air
The compressors shall be a welded high efficiency hermetic type with internal vibration isolation and be equipped with a
crankcase heater.
Coils shall be of non-ferrous construction with mechanically bonded aluminum plate fins Outdoor coils shall be made, of
9.52mm OD, 0.35mm thick formless copper tubes mechanically bonded to 0.12mm thick aluminum plate fins.
Face area of the coil shall not be less than __ m 2 The coil shall be factory pressure and leak tested at 3.3 MPa
pressure. The indoor coil face area shall be not less than __ m2.
Multi-wing propeller type fans shall be fitted at the condenser and shall be dynamically balanced, to ensure smooth
airflow and shall discharge vertically and be direct driven by a weatherproof three phase squirrel cage __kW induction
motor.
The system shall be factory wired and all electrical wiring must comply with the Local wiring code (Controls and control
wiring shall be supplied by the contractor). Compressors and fan motors shall have both internal and current sensitive
overload devices.
An automatic defrost control shall be included to accomplish defrosting (only if required) every __minutes for a
period of __minutes.
High pressure switch (pre-set) shall be factory installed.
The enclosure is weatherproof casing constructed of phosphatized, zinc coated steel with powder coating.
(OUTDOOR UNIT)
The unit shall be provided with hoisting plates for rigging and hoisting the unit. The hoisting plates shall be located in the
pillars. (OUTDOOR UNIT)
The unit shall have a drain connection provided (25mm BSP:male thread).
The enclosure shall have openings provided for power connections.
Access for both service and installation shall be provided to compressors, control wiring, and fans.
Side panels and top panels shall be removable for easy service access.
The unit maximum dimensions shall be : height: __mm, width: __mm and depth: __mm (INDOOR UNIT)
: height: __mm, width: __mm and depth: __mm (OUTDOOR UNIT)
Due to continuous product development, these guidelines are subject to change.
- 113 -
DATA BOOK
Issuued in Nov. 2002 MEE01K074-A
Printed in Japan.
PE,PEH
New publication effective Nov. 2002.
Specifications subject to change without notice.