Download Siemens RUGGEDCOM RSG2200 User guide

Transcript
RUGGEDCOM ROS
Chapter 5
User Guide
Setup and Configuration
Parameter
Description
IP Address
Synopsis: ###.###.###.### where ### ranges from 0 to 255
Default:
The IP address of the remote host.
IP Port
Synopsis: 1 to 65535 or { Unknown }
Default: 50000
The IP port that remote host listens to. If this is zero (Unknown), the unit only receives
from the remote host but does not transmit to it.
Port(s)
Synopsis: Any combination of numbers valid for this parameter
Default: All
The local serial ports that the remote host is allowed to communicate with.
4.
Click Apply.
Section 5.4.16.3
Deleting a Remote Host
To delete a remote host used by the Raw socket protocol, do the following:
1.
Navigate to Serial Protocols » Configure Protocols » Configure Raw Socket » Configure Remote
Hosts. The Remote table appears.
Figure 104: Remote Table
2.
Select the remote host from the table. The Remote form appears.
Deleting a Remote Host
147