Download Clever Acoustics SL 4240 User manual

Transcript
www.cleveracoustics.co.uk
SL 4120
4-CHANNEL AMPLIFIER
PROTECT
POWER
CLIP
TEMP
SIGNAL
CH2
CH1
4
ON
OFF
5
6
4
3
7
1
9
2
8
0
5
CH3
6
4
3
7
1
9
2
8
10
0
5
CH4
7
9
0
6
3
8
10
5
4
6
3
1
2
7
2
8
1
9
0
10
10
SL 4240
4-CHANNEL AMPLIFIER
PROTECT
POWER
CLIP
TEMP
SIGNAL
CH2
CH1
4
5
6
3
ON
OFF
4
7
9
1
0
10
5
CH3
6
3
8
2
4
7
9
1
0
10
5
CH4
6
3
8
2
4
7
9
1
0
10
5
6
3
8
2
7
8
2
9
1
0
10
SL 4120 100V 4 x 120W Slave Amplifier
Order code: CRAM22
SL 4240 100V 4 x 240W Slave Amplifier
Order code: CRAM23
USER MANUAL
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE
YOUR INITIAL START-UP!
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE RISK
OF ELECTRIC SHOCK!!
SAFETY INSTRUCTIONS
Every person involved with the installation, operation and maintenance of this equipment
should:
-
Be competent
-
Follow the instructions of this manual
CAUTION! TAKE CARE USING THIS EQUIPMENT!
HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
Before your initial start-up, please make sure that there is no damage caused during
transportation. Should there be any, consult your dealer and do not use the equipment.
To maintain the equipment in good working condition and to ensure safe operation, it is
necessary for the user to follow the safety instructions and warning notes written in this
manual.
Please note that damages caused by user modifications to this equipment are not subject
to warranty.
1
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused
by the non-observance of this manual or any unauthorised modification to the
equipment.
• Never let the power-cable come into contact with other cables. Handle the
power-cable and all mains voltage connections with particular caution!
• Never remove warning or informative labels from the equipment.
• Do not open the equipment and do not modify the equipment.
• Do not switch the equipment on and off in short intervals, as this will reduce the
system’s life.
• Only use the equipment indoors.
• Do not expose to flammable sources, liquids or gases.
• Do not carry the unit with only one handle. Always carry using both handles.
• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug
by pulling the power-cable.
• Make sure that the mains supply voltage is between 220V-240V.
• Make sure that the power-cable is never crimped or damaged. Check the
equipment and the power-cable periodically.
• If the equipment is dropped or damaged, disconnect the mains power supply
immediately.
Have a qualified engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic temperature fluctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
• If your product fails to function correctly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be carried out by a qualified
technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
• WARRANTY; One year from date of purchase.
• If this equipment is operated in any other way, than those described in this
manual, the product may suffer damage and the warranty becomes void.
• Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks.
• Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and property.
2
This 100V line slave amplifier was designed specifically for use in permanent audio
installations, where reliability and premium sound quality are a must. Highly rugged
construction and high efficiency design make this amplifier is ideal for continuous duty
applications in situations were power will be left on for indefinite periods of time.
This 100V line amplifier is warranted from defects for one year from the date of purchase.
Should your amplifier require service, either within or beyond that warranty period, please
contact your Prolight Dealer.
This unit includes a host of features, along with an impressive list of specifications, which
are detailed over the next pages. Please take the time to read this document completely
prior to installation of this product.
Slave amplifier series are designed to suit multi zone applications in schools, offices
and stores.
Features
• Four separate amplifiers in a single 19” rackmount chassis
• 70V, 100V and 4-16Ω loudspeaker outputs
• Balanced XLR line input for each channel
• Convenient phoenix type terminal block output connectors
• Temperature, over-load, clip and short circuit protection
• Power, signal, clip, protection and temperature LEDs
• Fan cooled
Specifications
SL 4120
SL 4240
Power output:
4 x 120Wrms
4 x 240Wrms
Speaker outputs:
70V, 100V & 4-16Ω
70V, 100V & 4-16Ω
Sensitivity:
775mV (0dB)
775mV (0dB)
S/N ratio:
>90dB
>90dB
Frequency response:
50Hz-16kHz, distortion
<1.5dB
50Hz-16kHz, distortion
<1.5dB
THD:
<1%
<1%
Cooling:
Fan cooled
Fan cooled
Indications:
Power, signal, protection and
peaking
Power, signal, protection and
peaking
Protection:
Power on, overload and short
circuit protection
Power on, overload and short
circuit protection
Power consumption:
720W
1500W
Power supply:
240V-50Hz
240V-50Hz
Dimensions (H x W x D):
88 x 484 x 448mm
132 x 484 x 448mm
Weight:
22kg
30kg
Order code:
CRAM22
CRAM23
3
6
SL 4120
1
2
3
4
5
6
4-CHANNEL AMPLIFIER
PROTECT
POWER
CLIP
TEMP
SIGNAL
CH2
CH1
5
4
ON
OFF
6
7
9
8
0
12
6
1
CH3
6
4
3
7
1
9
2
8
10
7
SL 4240
5
4
3
1
2
0
5
CH4
7
9
0
6
3
8
10
5
4
6
3
1
2
7
2
8
1
9
0
10
10
8
9
10
11
2
3
4
5
12
6
4-CHANNEL AMPLIFIER
PROTECT
POWER
CLIP
TEMP
SIGNAL
CH1
CH2
5
5
4
4
7
1
9
8
0
OFF
12
6
3
2
ON
4
7
1
9
8
10
7
CH3
6
3
2
0
8
4
7
9
10
0
9
10
10
5
6
3
8
7
8
2
9
1
0
10
11
12
13
4
70V
2
1
2
3
CH 3 IN
CH 4 IN
2
1
2
3
16 18
XLR BAL
INPUT
1-GND
2-HOT+
3-COLD-
1
3
100V
4
C OM
CH 4 OUT
100V
4
70V
C OM
CH 3 OUT
70V
~230V 50Hz 720W
T8AL 250V
13
CH 2 IN
100V
C OM
4
70V
CH 1 IN
CH 2 OUT
100V
C OM
CH 1 OUT
www.prolight.co.uk
17 19
1
3
20 22 21 23
SL 4240
13
2
3
1
XLR BAL
INPUT
1-GND
2-HOT+
3-COLD-
100V
4
70V
CH 2 OU T
C OM
100V
4
70V
CH 1 OU T
C OM
www.prolight.co.uk
CH4
6
1
SL 4120
14 15
5
3
2
CH 1 IN
CH 2 IN
T12AL 250V
2
1
2
3
100V
4
70V
CH 4 OU T
C OM
100V
4
70V
C OM
CH 3 OU T
~230V 50Hz
CH 3 IN
2
14 15
16 18
17 19
CH 4 IN
1
3
1
3
2
1
3
20 22 21 23
4
Identification:
1. Power LED - This LED will illuminate once the amplifier is switched on and is ready for use.
2. TEMP LED - Temperature LED will illuminate when overheating. Switch off the amplifier
and leave to cool down.
3. PROT LED - This LED will illuminate when the unit goes into protect mode. Switch off the
amplifier and check the output connections for faults or short circuits before powering on and
resuming operation.
4. CLIP LED - This LED will flash when the output signal starts to distort. At this point turn the
master volume anti-clockwise to prevent damage.
5. SIGNAL LED - This LED will light up when signal is being received .
6. Fan vent - Do not obstruct, keep clear of dust.
7. On/off power switch - Use the switch to power the unit on or off.
8. CH1 volume control - Use this control to increase or decrease the volume of channel 1.
9. CH2 volume control - Use this control to increase or decrease the volume of channel 2.
10. CH3 volume control - Use this control to increase or decrease the volume of channel 3.
11. CH4 volume control - Use this control to increase or decrease the volume of channel 4.
12. Carry handles
13. Fan vent - Do not obstruct, keep clear of dust.
14. Power input - 240V 50Hz.
15. Mains fuse - If the mains fuse requires replacement, use the same type and value as
originally supplied.
16. CH1 loudspeaker output terminals - Connectors for 4-16Ω or 70V and 100V speakers.
17. CH2 loudspeaker output terminals - Connectors for 4-16Ω or 70V and 100V speakers.
18. CH3 loudspeaker output terminals - Connectors for 4-16Ω or 70V and 100V speakers.
19. CH4 loudspeaker output terminals - Connectors for 4-16Ω or 70V and 100V speakers.
20. CH1 XLR signal input - Use this to connect signal input from mixer amplifiers.
21. CH2 XLR signal input - Use this to connect signal input from mixer amplifiers.
22. CH3 XLR signal input - Use this to connect signal input from mixer amplifiers.
23. CH4 XLR signal input - Use this to connect signal input from mixer amplifiers.
Rack Installation
The SL Series are rack mountable. The rack you use should be a double door rack where you can
open the front and rear panel. When mounting the amplifier into the rack, please make sure that
there is enough space around the amplifier for the clear flow of cool air and the exhaust of hot air.
Be careful when mounting the amplifier into the rack. Put the heaviest products into the lower part
of the rack. Be aware that fastening the amplifier with four screws on the front panel is not
sufficient to absorb impact from road transit vibrations, additional support may be required.
Inputs
Short cables runs improve the sound quality remarkably. Input cables should be short and direct,
since high frequencies will mostly be absorbed if the cables are unnecessarily long. Besides that
a longer cable may lead to humming and noise problems. If the cable runs are unavoidable, you
should use balanced cables.
Outputs
The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long
and thin cables used for low impedance (4-16Ω) speakers will influence the damping factor and
thus the low frequencies in a negative way.
5
Connect your speaker systems via the speaker terminals (COM = -VE)
Examples: 1) COM + 4-16Ω
2) COM + 70V
3) COM + 100V
Note: Please do not use more than one pair of output terminals
Connections To The Mains
Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth
to be connected at all times. DO NOT remove or disconnect the earth.
Power On/Off Procedure
After connecting your amplifier to the mains, turn all controls counter clockwise to the “min”
position. Turn on audio sources (MP3 players, CD players, Microphones etc) before powering the
amplifier ON. The last product to be switched on is the amplifier.
If you wish to power off the system, turn the amplifier’s master volume control counter clockwise
to the “min” position before switching the amplifier OFF before any audio sources are switched off.
By following this procedure it will prevent acoustic shocks to the speakers or potential damage to
system components.
Machine operation
1. After connecting all audio source and powering on the power amplifier, adjust the and the
master volume.
2. The Clever Acoustics amplifier features output signal LED with PEAK indication. Should the
PEAK indicator illuminate (flashing) the output of the amplifier is too high, turn the master volume
anti-clockwise to reduce the output.
3. The Clever Acoustics amplifier all features protection with LED indication. Should the
PROTECT indicator illuminate, turn the master volume control anti-clockwise fully and switch off
the amplifier for 15 seconds as the amplifier may have entered PROTECT mode temporarily due
to a peak signal, care should then be taken to ensure all input levels are set correctly. If the
amplifier persists to enter PROTECT mode the amplifier should be switched off and left to cool
for 5-10 minutes before switching back on. If the PROTECT indicator remains lit this indicates a
problem with the amplifier or amplifier load (ie Short Circuit).
4. Speaker & Amplifier systems can produce high sound pressure levels, please operate all
controls with caution to ensure people are not exposed to excessive or dangerous sound pressure
levels.
6
Panel Connections:
SL 4120, 4240
70V
4
CH 2 IN
100V
C OM
4
70V
CH 1 IN
CH 2 OUT
100V
C OM
CH 1 OUT
2
www.prolight.co.uk
1
2
3
CH 3 IN
CH 4 IN
100V
4
C OM
CH 4 OUT
100V
4
70V
C OM
CH 3 OUT
70V
~230V 50Hz 720W
T8AL 250V
XLR BAL
INPUT
1-GND
2-HOT+
3-COLD-
1
3
2
1
2
3
1
3
ZONE MIXER
EXTENSION LINK
3
-
2
0V
1
2
0V
1
OUTPUT
1.5V/600
+
+
3
-
2
0V
1
OUTPUT
1.5V/600
+
+
3
-
2
0V
1
OUTPUT
1.5V/600
+
+
3
-
2
0V
1
OUTPUT
1.5V/600
+
OUTPUT
+
3
-
2
0V
1
1.5V/600
+
dB
GAIN
dB
GAIN
dB
GAIN
dB
GAIN
dB
GAIN
dB
GAIN
dB
GAIN
dB
-
-
-
-
-
-
-
HF
HF
+10
dB
-10
HF
+10
dB
-10
HF
+10
dB
-10
HF
+10
dB
-10
HF
+10
dB
-10
HF
+10
dB
-10
HF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
LF
+10
dB
-10
ZONE
1
+
dB
-
PAGE
ZONE
2
+
dB
-
ZONE
3
+
dB
-
PAGE
REMOTE
WALL CONTROL
DISABLE
ENABLE
REMOTE
WALL CONTROL
DISABLE
ENABLE
ZONE
4
+
dB
-
PAGE
ZONE
5
+
dB
-
PAGE
PAGE
REMOTE
WALL CONTROL
DISABLE
ENABLE
ZONE
6
+
dB
-
REMOTE
WALL CONTROL
REMOTE
WALL CONTROL
DISABLE
ENABLE
ZONE
8
+
dB
-
PAGE
REMOTE
WALL CONTROL
DISABLE
ENABLE
DISABLE
ENABLE
ZONE
7
+
dB
-
PAGE
REMOTE
WALL CONTROL
DISABLE
ENABLE
REMOTE SOURCE 2
GAIN
3
2
0V
- dB +
L
195mV-2V/47K
L
GAIN
GAIN
- dB +
- dB +
GAIN
L
195mV-2V/47K
L
REMOTE SOURCE 3
GAIN
3
2
+
-
dB
1
0V
300mV-1.1V/10K
LINE 5
+ - G
GAIN
+
-
dB
1
300mV-1.1V/10K
R
REMOTE SOURCE 4
GAIN
3
2
+
-
dB
1
0V
300mV-1.1V/10K
LINE 6
+ - G
+ - G
REMOTE SOURCE 5
GAIN
3
2
+
3
-
dB
1
2
0V
300mV-1.1V/10K
LINE 7
DISABLE
ENABLE
1
REMOTE SOURCE 6
GAIN
3
2
1
300mV-1.1V/10K
+ - G
PAGING MIC1
GAIN
- dB +
MIC:5mV LINE:350mV
0V
REMOTE SOURCE 7
GAIN
dB
+
0V
REMOTE SOURCE 8
GAIN
3
2
dB
1
300mV-1.1V/10K
MICROPHONE 1
- dB +
MIC:5mV LINE:350mV
+
dB
300mV-1.1V/10K
LINE 8
LINE
MIC
P HANTOM
0V
LINE 4
LINE
MIC
P HANTOM
+
dB
LINE
MIC
P HANTOM
LINE 3
R
LINE
MIC
P HANTOM
ALE R T
G R OUND
E MC IN
E VAC
C OMMON
REMOTE SOURCE 1
GAIN
-
1
+
2
-
3
300mV-1.1V/10K
+
+
-
+
0V
dB
+
-
R
-
EMC
INPUT
+
+
dB
LINE 2
-
-
LINE 1
+
TONE
OUTPUT
4
-
B AT T S UP P LY
2A
24V
1.5V/600
+
3
-
775mV/10K
R
Speaker connections:
1
+
+
G
0V
OUTPUT
-
8
2
+
MAS T E R
S LAV E 1
S LAV E 2
S LAV E 3
1.5V/600
+
3
-
-
FIRE ALARM
CONTACT CLOSURE
2 3 4 5 6 7
1
+
+
1
0V
OUTPUT
-
3
2
REMOTE
WALL CONTROL
240V
INPUT VOLT AGE SELECTOR
1 2
ON
3
-
+10
dB
-10
PAGE
120V
1.5V/600
+
GAIN
LINK OUT
~120V/240V 50-60Hz
OUTPUT
+
LINK IN
MAINS
+
MIC:5mV LINE:350mV
MIC:5mV LINE:350mV
Total impedance
41Ω (SL 120)
20Ω (SL 240)
14Ω (SL 350)
PAGING MIC2
GAIN
- dB +
LF
GAIN
dB
-8
dB +8
HF
-8
dB +8
5mV-300mV/680
Total impedance
83Ω (SL 120)
42Ω (SL 240)
28.6Ω (SL 350)
Notes:
• Both the 4 - 16Ω, 70V and 100V terminals cannot be used at the same time.
• Impedances indicated in the figures represent the total speaker system (load) impedances.
Loads presented to the amplifier must be equal to or greater than listed above. Speaker
impedances must be measured using a true impedance meter, do not standard multimeters.
WARNING!
Be sure to attach the supplied terminal cover attached after connection. Because high
voltage is applied to the speaker terminals, care should be taken never touch these
terminals to avoid electric shock.
All speaker connections should be made using bare wire or suitable insulated crimp terminals.
Please ensure no loose strands are present as these may short across terminals causing damage
to the amplifier.
7
Connection With The Mains
Connect the SL 4120 unit to the mains via the IEC mains inlet using the 13A UK IEC
cord supplied. Connect the SL 4240 unit to the mains via the captive mains cord.
The earth has to be connected.
Switch the unit on. After switching on the speaker system, wait 8 - 10 seconds before you turn the
volume control up in order to avoid speaker damage.
CAUTION! Increase the level of each channel up to the point where the clip LEDs illuminate.
Always check the sound pressure level with a meter in order to keep to the legal threshold.
Balanced XLR Jack Connection
CAUTION
DANGER TO LIFE DISCONNECT
FROM THE MAINS BEFORE
STARTING MAINTENANCE
OPERATION
PROBLEM
CAUSE
SOLUTION
No power
The power cord is not connected.
Check the power cord and any
extension cables
No sound
The power cord of the
respective product is not
connected properly or not at all.
Check the power cord and if
the plugs are properly
connected with the sockets.
The connection socket or the
plug is dirty.
Clean the socket, and/or the
plug.
Noise
The input signal is too strong.
Reduce the input signal via the
gain control.
Distorted sound
Load impedance is to low.
Check the load impedance
vs amplifier specification, and
reduce if required.
Cleaning and Maintenance
We recommend a frequent cleaning of the product. Please use a soft lint free and moistened
cloth. Never use alcohol or solvents.
There are no serviceable parts inside the product except for the fuse. Maintenance and service
operations are only to be carried out by authorised dealers.
Replacing the fuse
Only replace the fuse by a fuse of the same type and rating.
Before replacing the fuse, unplug the mains lead.
Should you need any spare parts, please use genuine parts.
Should you have any further questions, please contact your dealer.
8
www.cleveracoustics.co.uk