VIP 10
User Guide
Copyright
This user guide is the intellectual property of VCS and is protected by copyright.
All rights reserved. No part of this document may be reproduced or transmitted
for any purpose, by whatever means, electronic or mechanical, without the
express written permission of VCS.
Release: February 2005 (Firmware Version 2.1)
© 2005, VCS Video Communication Systems AG
Note
This user guide has been compiled with great care and the information it contains
has been thoroughly verified. The text was complete and correct at the time of
printing. Due to further product development, the contents of the user guide may
change without prior notice. VCS accepts no liability for damages resulting
directly or indirectly from errors, omissions or discrepancies between the user
guide and the product described.
Trademarks
All hardware and software product names used in this document are likely to be
registered trade marks and must be treated accordingly.
Contents
Contents
0
Chapter 1 Preface
About this user guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EU guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rating plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
7
8
8
8
Chapter 2 Safety Information
Electrical shock hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation and operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance and repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 3 Product Description
Supplied components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System requirements for setup . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operational requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VIP 10 connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
11
12
13
16
Chapter 4 Installation
Installing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switching on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setup using terminal software . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
18
20
21
Chapter 5 Configuration using a Web Browser
Establishing the connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Choosing the configuration mode . . . . . . . . . . . . . . . . . . . . . . . .
Configuration with the Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration in Expert Mode . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
28
29
32
Chapter 6 Configuring the Sender
Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Unit identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
VIP 10
3
Contents
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Time server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Camera name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display stamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Picture settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MPEG-4 encoder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio stream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Video input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JPEG posting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motion detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multicasting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Version information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Livepage configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firmware and configuration upload . . . . . . . . . . . . . . . . . . . . . . .
Function test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
37
38
39
39
40
41
44
45
46
47
49
50
54
56
57
60
62
63
66
68
Chapter 7 Configuring the Receiver
Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Password. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Time server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MPEG decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio stream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Version information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firmware and configuration upload . . . . . . . . . . . . . . . . . . . . . . .
Function test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
69
69
70
71
71
72
73
74
75
76
77
79
80
83
83
86
4
VIP 10
Contents
Chapter 8 Sender Operation
Operation with Microsoft Internet Explorer . . . . . . . . . . . . . . . . .
The Livepage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving snapshots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording video sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . .
87
88
93
94
Chapter 9 Receiver Operation
Operation with Microsoft Internet Explorer . . . . . . . . . . . . . . . . . 95
The Decoder connection page. . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Connection between the receiver and sender . . . . . . . . . . . . . . . 97
Chapter10 Hardware Connections
Hardware connections between VCS units . . . . . . . . . . . . . . . . . 99
Establishing the connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Closing the connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Chapter11 Operation with Decoder Software
Operation with VIDOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Chapter12 Maintenance and Upgrades
Testing the network connection . . . . . . . . . . . . . . . . . . . . . . . . .
Device reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transfer and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
105
105
106
106
Chapter13 Appendix
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RS232/485 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VIP 10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
107
109
110
111
112
114
Chapter14 Index
VIP 10
5
Contents
6
VIP 10
Preface
1
About this user guide
This user guide is intended for persons responsible for the installation and
operation of the VIP 10 network video server. International, national and any
regional regulations regarding electrical systems must be adhered to at all times.
Adequate knowledge of network technology is a precondition. The user manual
describes the installation and operation of the unit.
Conventions
Symbols and notation
The following symbols and notation highlight important situations and
information.
Warning!
This symbol indicates that failure to follow the safety instructions described
may endanger persons and cause damage to the unit or other equipment.
It is associated with immediate, direct hazards.
Note
This symbol indicates tips and information for easier, more convenient use
of the unit.
VIP 10
7
Preface
Chapter 1
Intended use
The VIP 10 network video server transmits video, audio and control signals over
data networks (such as Ethernet LANs and the Internet). It is designed for use in
CCTV systems. By incorporating external alarm devices, various functions can
be triggered automatically. Other applications are not authorized.
For questions regarding the use of the unit that are not answered in this user
guide, please contact your local dealer or:
VCS Video Communication Systems AG
Forchheimer Strasse 4
90425 Nuremberg, Germany
Phone: +49 (0)911 9 34 56-0
Fax: +49 (0)911 9 34 56-66
[email protected]
EU guidelines
The VIP 10 network video server complies with the specifications of EU
Directives 89/336 (Electromagnetic Compatibility) and 73/23, amended by 93/68
(Low Voltage Directive).
Rating plate
For exact identification of the unit, the model and serial number are inscribed on
the rating plate on the bottom of the housing. Please note this information before
starting installation, so that you have it ready if you need to ask for assistance or
order spare parts.
8
VIP 10
Safety Information
2
Electrical shock hazard
] Never attempt to connect the unit to any power network other than the type for
which it was intended.
] Use only the power supply provided.
] Never open the casing!
] If a fault occurs, disconnect the power supply unit from the mains supply and
from all other devices.
] Install the unit and power supply only in dry, weather-protected areas.
] If safe operation of the unit cannot be guaranteed, remove it from service and
secure it to prevent unauthorized start-up. Safe operation can no longer be
guaranteed, for example,
– if there is visible damage to the unit or power cables,
– if the unit no longer works properly,
– if the unit has been exposed to rain or moisture,
– if foreign matter has infiltrated the unit,
– after long storage under adverse conditions or
– after exposure to higher than normal stress during transport.
In such cases, have the unit checked by VCS.
VIP 10
9
Safety Information
Chapter 2
Installation and operation
] Relevant electrical codes and guidelines must be complied with at all times
during installation.
] Adequate knowledge of network technology is necessary for the installation.
] Before installing or operating the unit, make sure you have read and
understood the documentation for the other equipment connected to the
system, such as cameras. There you will find important safety instructions and
information about authorised use.
] Perform only the installation tasks and operating steps described in this
manual. Additional actions may lead to personal injuries, property damage or
damage to the equipment.
Maintenance and repair
] Never open the casing of the VIP. The unit does not contain parts that you can
repair or replace.
] Never open the housing of the power supply unit. The power supply unit does
not contain parts that you can repair or replace.
] Ensure that all maintenance or repair work is performed exclusively by
qualified personnel.
10
VIP 10
Product Description
3
Supplied components
] Network video server VIP 10 including plug-in mains adapter
] RS232 null modem cable
] The quick start guide “First Steps” in English and German
] VCS product CD with the following content:
– The quick start guide “First Steps” in English and German
– User guide in English and German
– MPEG-ActiveX control from VCS
– MPEG-Viewer
– DirectX control
– Microsoft Internet Explorer
– Microsoft Virtual Machine
– Adobe Acrobat Reader
System requirements for setup
] Computer with Microsoft Windows 98/2000/XP operating system
and
– network access and Microsoft Internet Explorer (version 5.5 or higher)
or
– a free serial port and terminal software
Configuration requirements
] Computer with Microsoft Windows 98/2000/XP operating system and network
access and
– Microsoft Internet Explorer (version 5.5 or later)
or
– decoder software, such as VIDOS from VCS
VIP 10
11
Product Description
Chapter 3
Note
Make sure the graphic card is set to 16 or 32 bit color depth and Microsoft's
Virtual Machine is installed and active on your computer.
Operational requirements
] Computer with Microsoft Windows 98/2000/XP operating system and network
access and
– Microsoft Internet Explorer (version 5.5 or later)
or
– decoder software, such as VIDOS from VCS
or
] Hardware receiver from VCS (e.g. VIP 10 E) and video monitor
Note
Make sure the graphic card for receiving on the computer monitor is set to
16 or 32 bit color depth and Microsoft's Virtual Machine is installed and
active on the computer.
12
VIP 10
Chapter 3
Product Description
Overview of functions
Network video server
The VIP 10 is an ultra-compact network video server. Its primary function is to
encode and decode video, audio and control data for transmission over an IP
network. The VIP 10 is particularly well suited to adapting analog cameras for IP
communication and for remote access to digital video recorders and multiplexers.
About the size and shape of a cigarette packet, it can be integrated into small
enclosures without difficulty. The use of existing networks means that integration
with CCTV systems or local networks is quick and easy.
Two units, a VIP as the sender and another VIP as the receiver, can form a standalone system for data transfer without a PC. Video images from one sender can
be received simultaneously on a number of receivers.
Receiver
VIP or VideoJet units from VCS can be used as receivers. Computers with
decoding software such as VIDOS from VCS or Microsoft Internet Explorer can
also be used as receivers.
Video encoding
The VIP 10 works with the MPEG-4 video compression standard. MPEG-4
enables data transfer at narrow bandwidth – via Internet for example.
Dual streaming
Dual streaming allows the incoming data stream to be encoded simultaneously
according to two different, individually customizable profiles. This creates two
data streams that can serve different purposes, for example one for local
recording and one optimized for transmission via the LAN.
Multicast
In suitably configured networks, the multicast function enables simultaneous, real
time video transmission to multiple receivers. The prerequisite for this is that the
UDP and IGMP protocols be implemented on the network.
VIP 10
13
Product Description
Chapter 3
Remote control
The VIP can remotely control external devices, such as pan and tilt heads or
motorized zoom lenses, by transmitting control data via its bidirectional serial
interface. This interface can also be used to transmit transparent data.
Configuration
The VIP can be configured using a browser on the local network (Intranet) or via
Internet.
Firmware updates and fast loading of device configurations are possible in the
same way.
Recording and playback
You can save the video images provided by the unit as a file on the hard drive of
your computer. The video sequences are stored in MPEG format and can be
replayed with the VCS MPEG-Viewer included with the package.
Snapshots
Individual video frames (snapshots) can be called up as JPEG images by the VIP,
stored on the hard drive or displayed in a separate browser window.
Backup
Backups of video sequences can be made to the hard drive with a simple mouse
click on an icon on the Livepage .
14
VIP 10
Chapter 3
Product Description
Summary
The main functions of the VIP 10 are:
] Video, audio and data transmission over IP data networks
] Simultaneous dual streaming with two independently defined profiles
] Multicast function for simultaneous picture transmission to multiple receivers
] Analog BNC composite video input FBAS (PAL/NTSC) (sender)
] Analog BNC composite video output FBAS (PAL/NTSC) (receiver)
] A bidirectional audio input/output (mono)
] Video and audio encoding using the MPEG-4/G.711 international standards
] Integrated Ethernet interface (10/100 Base-T)
] A transparent bidirectional data channel using a serial interface, type
RS232/485
] Remote control of all built-in functions via TCP/IP
] Password protection to prevent unauthorized connection or configuration changes
] Alarm inputs for external sensors (such as a door contact)
] Relay output for switching external devices (such as lights or audible alarms)
] Event-driven, automatic connection (for example when switching on and
when alarms are activated)
] Fast, convenient configuration using a Web browser
] Firmware update using flash memory
] Convenient upload of configuration data
VIP 10
15
Product Description
Chapter 3
VIP 10 connections
1
2
Video In
RS232/485
Li LoIN1 R +
USB
GNDIN2 R
3
4
5
ñ
Ethernet
6
7
8
9
1 BNC jack: Video In (transmitter) or Video Out (receiver),
for connecting a video source or an analog video monitor
2 RJ45 jack for RS232/485
for transmitting control data and
configuration with terminal software
3 USB interface
for future expansion of the recording function
4 Reset button for restoring the default settings
5 Terminal block (audio, alarms, relay and power supply)
6 Operating status LED
yellow, lights up when the device is ready for operation
7 Network connection LED
green, lights up when the device is connected to the network
8 Data transfer LED
blinks orange when data is transmitted over the network
9 RJ45 jack for Ethernet
for connecting to the network
16
VIP 10
Installation
4
Installing the unit
With its ultra-compact dimensions, the VIP is particularly well suited for
installation in cabinets.
Warning!
The unit is intended for use indoors or in a protective enclosure. Select a
suitable location for installation where the equipment is not subject to
extreme temperatures or humidity. The ambient temperature must lie
between 0 and +50 °C. The relative humidity should not exceed 80%.
The unit generates heat during operation. Ensure that there is adequate
ventilation and also that there is enough clearance between the unit and
heat-sensitive objects or equipment.
Make sure the following conditions for installation are complied with:
] Do not mount the unit close to heaters or other heat sources. Avoid locations
subject to direct sunlight.
] Allow sufficient space for running cables.
] Ensure that the unit has adequate ventilation.
] Use only the cables supplied for connections or appropriate cables, which are
also shielded against electromagnetic interference.
] Position and run all cables so that they are protected from damage, and
provide strain relief where needed.
VIP 10
17
Installation
Chapter 4
Connections
Camera/monitor
Depending on the device used, you can connect a video source (sender) or a
monitor (receiver). All cameras and video sources that generate a standard PAL
or NTSC signal and all monitors compatible with PAL or NTSC standards can be
used for this purpose.
– Connect the camera or another video source using a video cable (75 Ohms,
BNC plug) to the Video In BNC jack of the sender.
or
– Connect the video monitor using a video cable (75 Ohms, BNC plug) to the
Video Out BNC jack of the receiver.
Data interface
The bidirectional data interface is used to control equipment connected to the VIP
unit, such as a dome camera with a motorized lens.
The RS232/485 connection supports RS232, RS422 and RS485 communication
standards.
The serial interface is a Sub-D socket. For information on the pin assignment see
page 110.
The selection of controllable devices is growing constantly. The manufacturers of
this equipment can provide specific information on installation and control.
Warning!
Make use of the device documentation when installing and operating a
device that you want to control using the system. It contains important
safety instructions and information about authorized use.
Note
A video connection is necessary to transmit transparent data.
18
VIP 10
Chapter 4
Installation
Network
You can connect the VIP to a 10/100 Base-T network. Use a standard UTP
Category 5 cable with RJ45 connectors for this.
– Connect the unit to the network using the Ethernet jack.
Alarm inputs
The VIP has two alarm inputs on the orange terminal block. The alarm inputs are
used to transfer signals from external alarm devices, such as door contacts or
sensors. Given the appropriate configuration, an alarm device can, for example,
trigger automatic connection between the VIP and a remote location. A voltage
free normally open contact or switch can be used as an actuator.
Note
It is preferable to use an actuator with a bounce-free contact system.
– Connect the leads to the appropriate terminals on the orange terminal block
and check that the connection is secure (for pin assignment see page 111).
Relay output
The VIP has a relay output for switching external devices, such as lights or
audible alarms. This relay output can be activated manually if there is an active
connection with the VIP. Moreover, the output can be configured to activate
audible alarms or other devices as a response to an alarm signal. The relay
output is also located on the orange terminal block.
Warning!
The maximum rating of the relay contact is 30 V and 1 A.
– Connect the leads to the appropriate terminals on the orange terminal block
and check that the connection is secure (for pin assignment see page 111).
Microphone/loudspeaker
The connection for the microphone/loudspeaker is also on the orange terminal
block.
The bidirectional audio signals are transmitted simultaneously with the video
signals. This can be used for example to operate a loudspeaker or door intercom
at the target location.
VIP 10
19
Installation
Chapter 4
– Connect a line level audio source to the appropriate terminals on the orange
terminal block of the sender and check that the connection is secure.
– Connect a loudspeaker to the appropriate terminals on the orange terminal
block of the receiver and check that the connection is secure (for pin
assignment see page 111).
Switching on/off
Power connection
A plug-in mains adapter is included with the VIP package. The VIP does not have
a mains switch. The unit is ready for operation as soon as it is connected to the
mains supply.
Warning!
Use only the plug-in mains adapter provided for operation of the VIP. Where
necessary, take appropriate measures to ensure that the mains supply is
protected against voltage surges, spikes or brownouts.
Warning!
Do not connect the VIP to the power source until all the other connections
have been made.
– Connect the cable of the mains adapter to the orange terminal block of the VIP.
– Plug the mains adapter into a fused power socket. The unit is ready for
operation as soon as the "operating status" LED stops blinking red during
start-up and becomes yellow.
If the network connection is in order, the green "network connection" LED is also
lit. The blinking orange "data transmission" LED indicates data traffic on the
network.
20
VIP 10
Chapter 4
Installation
Setup using terminal software
Data terminal
You can connect a data terminal to the VIP for setup and local control. The data
terminal consists of a computer with terminal software. Use the serial null-modem
cable included in the package supplied to make the connection.
For example, HyperTerminal, a communications utility included with Microsoft
Windows, can be used as the terminal program.
Note
Information on installing and using HyperTerminal can be found in the user
guides or online help for Microsoft Windows.
– Before working with the terminal program, disconnect the VIP from the data
network.
– Connect the RS232/485 Sub-D connector of the VIP to an available serial port
on the computer.
Configuring the terminal
To establish communication between the terminal program and the VIP, the
transmission parameters must be correctly defined. Set the following values in the
terminal program:
] 19,200 Bit/s
] 8 data bits
] No parity check
] 1 stop bit
] No protocol
Command entry
After the connection has been established, you must log on to the VIP. You can
then access the main menu. You can call up additional submenus and functions
using the on-screen commands.
] If necessary, turn off the local echo so that entered values are not repeated on
the screen display.
VIP 10
21
Installation
Chapter 4
] Enter only one command at a time.
] After entering a value (such as an IP address), re-check the entry before
pressing the Enter key to send the data to the VIP.
Assigning an IP address
To operate the VIP on your network, you must assign it an IP address that is
recognized by the network.
The following default address has been pre-set at the factory:
Sender: 192.168.0.1
Receiver: 192.168.0.2
– Start up a terminal program such as HyperTerminal.
– Enter service as user name and password. The main menu will be
displayed.
– Enter i to open the IP menu.
– Enter i once more. The current IP address will be displayed, and you will be
requested to enter a new IP address.
– Enter the desired IP address and press [ENTER]. The new IP address will be
displayed.
– If necessary, enter s and a new subnet mask.
22
VIP 10
Chapter 4
Installation
Note
The new IP address, subnet mask and gateway adress become effective
only following a restart.
Restart
– Enter #reset and press [ENTER]
or
– Interrupt the power supply of the VIP for a moment.
Additional parameters
Using the terminal program, you can check other basic parameters and modify
them where necessary. Use the on-screen commands displayed in the various
submenus for this purpose.
VIP 10
23
24
VIP 10
Configuration using a Web Browser
5
Establishing the connection
The integrated HTTP server allows the unit to be configured over the network
using a Web browser. This option offers considerably more possibilities and is
more convenient than configuration using terminal software. It also allows live
video images to be displayed.
Note
Make sure the graphic card is set to 16 or 32 bit color depth and the
Microsoft Virtual Machine is installed and active on your computer. If
necessary, the required software and controls can be installed from the CD
provided (see page 11).
Instructions for using the Web browser can be found in its online help.
System requirements
] Microsoft Internet Explorer (version 5.5 or higher)
] Monitor resolution 1024 × 768 pixels
] Network access (intranet or Internet)
MPEG-ActiveX installation
In order to display live video images, an appropriate MPEG-ActiveX must be
installed on the computer, such as that used for playing DVD movies. If
necessary, the required software and controls can be installed from the CD
provided (see page 11).
– Insert the CD into the CD-ROM drive of the computer. The CD should start
automatically. If the CD does not start automatically, open the root directory of
the CD in Windows Explorer and double click MPEGAx.exe.
– Follow the instructions on the screen.
VIP 10
25
Configuration using a Web Browser
Chapter 5
Establishing the connection
The VIP must be assigned a valid IP address for your network, before it can be
operated in your network environment.
The following default address has been pre-set at the factory:
Sender: 192.168.0.1
Receiver: 192.168.0.2
– Start the Web browser.
– Enter the IP address of the VIP as the URL. The VIP home page will be shown
in the browser.
If the unit is a sender, the home page will be the Livepage (which shows the live
video image).
26
VIP 10
Chapter 5
Configuration using a Web Browser
The Decoder connection page will be displayed as the home page for a
receiver. It shows a snapshot from the video source for the sender currently
connected, and the unit searches the network automatically for available
senders.
Note
If the connection cannot be established, the unit selected may already be
in communication with another remote station. Depending upon the
network configuration and the individual units, a sender can serve up to five
receivers simultaneously.
VIP password protection
If the VIP is password-protected against unauthorized access, a dialog box
requesting the password will appear first.
Note
Configuration work can only be performed on a password-protected VIP
unit if the user logs on under the service user name.
– Enter the user name and password in the appropriate fields.
– Click OK. If the password is correct, the VIP home page will open.
VIP 10
27
Configuration using a Web Browser
Chapter 5
Choosing the configuration mode
There are two options to configure the VIP or to check the current setup:
] the Wizard and
] Expert Mode.
All settings are stored in the VIP memory, and they are preserved even if the
power is interrupted.
Use of the Wizard is recommended for initial setup. It takes you step by step
through the necessary settings. It prevents critical settings for correct operation
being overlooked. Moreover, each step offers brief instructions that help with
installation.
Expert Mode is recommended only for experienced users or system
administrators. All unit parameters can be accessed in this mode. Operations that
affect the basic functionality of the unit (such as firmware updates) can only be
performed in Expert Mode.
Note
Depending on whether the unit is a sender or a receiver, different home
pages will be displayed. (For the sender, see page 26. For the receiver, see
page 27).
– Click the Settings link in the top part of the VIP sender Livepage. A new page
will open, and the desired configuration mode can be selected using the links
at the top of the window.
28
VIP 10
Chapter 5
Configuration using a Web Browser
Configuration with the Wizard
The Wizard is used for step-by-step configuration of the VIP. It will lead you
through a series of screens where you can input the necessary settings. The
settings only become effective after the last screen of the Wizard has been
completed. When working with the Wizard, you can switch to another window at
any time.
The last screen of the Installation Wizard offers the option of launching the
Application Wizard. The Application Wizard helps you to configure the Livepage.
It is used in a manner similar to the Installation Wizard.
Starting the Wizard
The Wizard can be launched from the configuration pages.
– Just click the link Wizard in the top part of the window. A new page will appear.
– Click the button with the wizard icon in the Installation wizard field. The first
screen for the Installation Wizard will appear.
– Click Start to launch the Wizard. The next screen for the Wizard will appear.
VIP 10
29
Configuration using a Web Browser
Chapter 5
General procedure
The screens for the Installation Wizard will be shown in sequence, allowing you
to work quickly and easily. The upper part of the window always contains
information about the settings options. The current settings are shown in the
lower part of the window. You can change settings by entering the desired value
in a text field or choosing it from a list. The navigation buttons for the Installation
Wizard are at the bottom of the window. You can switch between pages of the
Wizard at any time.
Note
Your screen display may differ slightly from the illustration, depending on
whether you are working with a sender or a receiver. However, the
configuration procedure with the Installation Wizard is the same for all units.
– Always read the information in the upper part of the window first.
– Click in the text fields to enter values or use the other controls available, such
as buttons, check boxes or list fields.
– Click Next >> to go to the next step.
– Click << Back to look at the previous step again.
– Click Cancel to interrupt the process and close the Installation Wizard.
30
VIP 10
Chapter 5
Configuration using a Web Browser
Finishing the configuration
After you have specified all the settings you want, they must be transmitted to the
VIP unit and saved. Click Finish in the last screen of the Installation Wizard to
complete this process.
Warning!
All settings changes will become effective only after you have ended the
configuration by clicking Finish in the last screen.
– Go to the last screen of the Installation Wizard if necessary.
– Click Finish to finalize the configuration. All settings will be transmitted to the
VIP and become effective forthwith.
VIP 10
31
Configuration using a Web Browser
Chapter 5
Configuration in Expert Mode
Expert Mode allows all parameters of the VIP to be configured. You can view the
current settings by opening one of the configuration pages. The settings can be
changed by entering new values or by selecting a predefined value in a list field.
The basic use of the configuration pages is described below. Separate
descriptions of the individual configuration pages and customizable parameters
for senders and receivers can be found in Chapter 6 and Chapter 7 of this user
guide.
Navigation
You can switch to Expert Mode from the configuration pages.
– Click the Expert Mode link. The initial page will be opened.
– Click one of the links on the left edge of the window. The corresponding page
will be opened.
Note
Your screen display may differ from the illustration, depending on whether
you are working with a sender or a receiver. However, navigation on the
configuration pages is the same for all units.
32
VIP 10
Chapter 5
Configuration using a Web Browser
Making changes
Each configuration page shows the current settings. You can change the settings
by entering new values or by selecting from predefined lists.
– Click Set after each change to save it.
Warning!
Save each change with the associated Set button. When Set is clicked,
only the changes in the relevant field are saved. Changes in any other fields
are ignored.
VIP 10
33
34
VIP 10
Configuring the Sender
6
Basics
The VIP offers various configuration options. Configuration in Expert Mode with
a Web browser is described below. Basic information about configuration with a
Web browser and other configuration options are described in Chapter 5 of this
user guide.
Unit identification
The unit can be assigned a name and an ID to facilitate identification. Both make
the task of managing video surveillance systems with VIDOS from VCS or other
tools much simpler.
Unit name:
Enter a name for the unit here.
Unit ID:
Each VIP should be assigned a unique identifier that can be entered here as an
additional means of identification.
VIP 10
35
Configuring the Sender
Chapter 6
Password
A VIP unit is generally protected by password to prevent unauthorized access.
You can limit the scale of access by choosing between different authorization
levels.
Note
Correct password protection is only granted when all higher levels of
authorization are also protected by password. If a live password is
assigned, for example, also a service and a user password must be
assigned. Therefore assign passwords always beginning with the highest
authorization level.
User name:
The sender operates with three user names: service, user and live which refer
to different authorization levels.
The user name service refers to the highest authorization level. Logged in under
service, you can use all the functions offered by the VIP and change all settings.
The user name user refers to the medium authorization level. Logged in under
user, you can operate the device and other devices, such as a camera, but no
changes can be made to the configuration.
The user name live refers to the lowest authorization level. Logged in under live,
you can only view the live video image and switch between the various live image
feeds.
Password:
You can define and change a unique password for each user name if you are
logged on under service or if the unit is not protected by a password.
Enter a password for the chosen user name here.
36
VIP 10
Chapter 6
Configuring the Sender
Confirm password:
Re-enter the new password to prevent typing mistakes.
Note
The new password becomes effective only after you have clicked Set.
Therefore click Set immediately after having entered and confirmed the
password even if you want to assign a password to another user name, too.
Language
If more convenient, a different operating interface language can be chosen.
Website language:
Select the language from the dropdown field.
Date and time
If a number of VIP units are part of a system, it is important that the internal clocks
of these separate units be synchronized. Only if all units operate with the same
time it is possible, for example, to correctly identify and evaluate recordings that
have been made simultaneously.
Date format:
Choose the desired date format here
(Europe: DD.MM.YYYY; USA: MM.DD.YYYY; Japan: YYYY/MM/DD).
VIP 10
37
Configuring the Sender
Chapter 6
Unit date:
Enter the current date here. Since the system time is controlled by the internal
clock, it is not necessary to enter the day of week. This is added automatically.
Unit time:
Enter the current time here or click the Synchr. PC button to copy the system
time of your computer to the VIP.
Time server
Using the Time Server Protocol the VIP can receive a time signal from a time
server and use it to set its internal clock. The device calls up the time signal
automatically every two hours.
Time zone:
Select the time zone that applies to your system.
Time settings:
Select this during daylight savings time if the time change is to be taken into
account. Deselect it when standard time has resumed.
Time server IP address:
Enter the IP address of the chosen time server here.
38
VIP 10
Chapter 6
Configuring the Sender
Camera name
The camera name simplifies identification of the remote camera location, for
example in the event of an alarm call. It will be shown in the video image if this
facility has been configured (see page 39). Moreover, the camera name is used
by VIDOS, VCS software for managing video surveillance systems, and makes it
easier to identify the camera.
Camera:
Enter a unique, unambiguous name for the camera in this field.
Display stamping
Various overlays or stamps in the video image provide important supplemental
information. These overlays can be enabled individually and arranged on the
image in a clear manner.
Camera name stamping:
This field sets the position of the camera name overlay. It can be shown at the
Top or the Bottom or you can define a position yourself via the Hyperterminal
and activate it choosing the option Custom. Or it can be set to Off if no overlay
for this information is to be shown.
VIP 10
39
Configuring the Sender
Chapter 6
Time stamping:
This field sets the position of the time and date overlay. It can be shown at the
Top or the Bottom or you can define a position yourself via the Hyperterminal
and activate it choosing the option Custom. Or it can be set to Off if no overlay
for this information is to be shown.
Alarm mode stamping:
Choose On if a text message should be overlaid in the event of an alarm.
Displayed alarm message:
Enter the message to be displayed for an alarm. The field can contain up to 31
characters.
Video watermarking:
Choose On if the video images transmitted are to be "watermarked". After
activation, all images will be marked with a green W. A red W indicates that the
sequence (live or saved) has been manipulated.
Picture settings
You can set up the video picture to meet your own particular requirements. To
enable you to control the current video picture it is shown in a small window
beside the sliders. The changes are effective immediately.
40
VIP 10
Chapter 6
Configuring the Sender
– If necessary click the Default button to return the configuration back to the
standard settings.
Contrast (0...255):
You can adjust the contrast of the video picture to suit the working environment.
Saturation (0...255):
You can use this function to set the color saturation and achieve the most realistic
color reproduction on the monitor.
Brightness (0...255):
You can use this function to adjust the brightness of the video picture to suit the
working environment.
MPEG-4 encoder
The VIP sender has two MPEG-4 encoders that can be configured separately.
The benefit of this so-called "dual streaming" is that you can transmit and record
simultaneously with different compression settings. The parameters for each can
VIP 10
41
Configuring the Sender
Chapter 6
be configured to suit the environment used (network architecture, bandwidth,
data structures, etc.).
There are several pre-programmed profiles available for both MPEG-4 streams.
These are optimized for different application scenarios. Individual settings in a
profile and its name can be changed.
Warning!
The profiles are rather complex. They include a number of parameters that
interact with one another. Therefore it is generally best to use the profiles
as provided. The profiles should only be changed after you have
familiarized yourself with all the configuration options.
MPEG-4 encoder
You can switch between the profiles of the two MPEG-4 streams by clicking the
associated tabs. The choice of the MPEG-4 Livepage stream is set on the
Livepage configuration page (see page 63).
Active profile:
Profiles can be selected here for each of the two streams.
Eight pre-programmed profiles are available optimized for different transmission
modes:
] Low bandwith (CIF)
for connections with low bandwidth, resolution 352 × 288 pixels
] Low delay (1/2 D1)
for connections with low delay, resolution 352 × 576/480 pixels (parameter
displayed for Video resolution: Custom)
] High resolution (D1/4CIF)
for connections with high resolution, resolution 704 × 576/480 pixels
] DSL
for DSL connections with 500 kBit/s
] ISDN (2B)
for ISDN connections via two B channels
] ISDN (1B)
for ISDN connections via one B channel
42
VIP 10
Chapter 6
Configuring the Sender
] Modem
for analog modem connections at 20 kBit/s
] GSM
for 9600 baud GSM connections
Warning!
When assigning the profiles take into account that in case of alarm
connections and auto-connect always Stream 1 is transmitted.
Profile configuration
You can switch between the profiles by clicking the associated tabs.
Note
The parameters as a group constitute a profile and are dependent on one
another. If you enter a setting outside the allowed range for the parameter,
the nearest valid value will be substituted when the settings are saved.
Profile name:
Enter a name for the current profile. The name will be displayed automatically in
the dropdown list of the field Active profile.
Data rate:
The data rate for the speed of transmission over the network is shown for each
profile. You can change the data rate.
Video quality:
Here you can adjust video quality as a function of the level of movement within
the frame. The Auto option automatically adjusts to the optimum relationship
between movement and image definition (focus). Manual allows you to set a
value between 1 and 31 on a slide bar. The value 1 gives the highest quality with
the lowest frame refresh rate. The value 31 results in a high refresh rate and low
image quality.
I-frame distance:
This parameter determines the number of frames between two I-frames
VIP 10
43
Configuring the Sender
Chapter 6
Encoding interval:
This setting determines the frame encoding interval. The value 1 means each
image is encoded. The value 2 means that only every other image is encoded,
etc. The lower the available transmission bandwidth, the higher this value should
be set in order to maintain high-quality images despite the bandwidth.
Video resolution:
Select the desired resolution for the MPEG-4 video image. The following options
are available:
] QCIF
176 × 144 pixels
] CIF
352 × 288 pixels
] 2CIF
704 × 288 pixels
] D1/4CIF 704 × 576/480 pixels
] Custom 352 × 576/480 pixels, adjustable (default setting is 1/2 D1)
Field mode:
This parameter determines the video signals being Interlaced or Progressive.
Reset of profile:
Click the Default button to reset the profile to its factory presets.
Audio stream
In addition to video data, the unit can also send and receive audio signals. The
transmission of audio takes place at the same time as that of the video data in a
separate data stream. Thus it increases the data traffic. The audio data is coded
according to G.711 compression standard and requires an additional bandwidth
of about 80 kBit/s per direction.
44
VIP 10
Chapter 6
Configuring the Sender
Warning!
G.711 audio data is only saved with central recording, using VIDOS-NVR
for example.
Enable audio:
To transmit a separate G.711 audio stream choose On.
Video input
The 75 Ohm termination of the VIP can be set here. If the video signal is to be
looped through, the termination must be set off. The default setting for the video
input termination is On.
75 Ohm termination:
To loop the video signal through choose Off.
VIP 10
45
Configuring the Sender
Chapter 6
JPEG posting
You can store video images in JPEG format at certain intervals on an FTP server.
These images can be called up again later, thus enabling for example alarm
events to be reconstructed.
JPEG format:
Here you can choose the format of the JPEG pictures:
] S
176 × 144 pixel (QCIF)
] M
352 × 288 pixel (CIF)
] XL
704 × 576 pixel (4CIF)
File name:
You can set what file names are to be generated for the transmitted snapshots.
] Overwrite: The same file name is always used. The existing file is
continuously over-written with current data.
] Increment: A number from 000 to 255 is attached to the filename. This
automatically increases by 1 every time a new file is created. When 255 is
reached the numbers begin again at 000.
] Date/time suffix: A date and time code are automatically incorporated into the
file name. When choosing this setting take care that the device’s date and time
are set correctly. Example: the file snap011204_114530.jpg was saved on
December 1st, 2004, at 11.45 and 30 seconds.
46
VIP 10
Chapter 6
Configuring the Sender
JPEG posting interval:
Enter the time interval here at which the single images are to be sent to an FTP
server. Enter zero, if no single images are to be sent.
FTP server IP address:
Enter here the IP address of the FTP server on which the JPEG-images are to be
stored.
FTP login name:
Enter your login name for the FTP server here.
FTP password:
Enter the password for the access to the FTP server here.
Path on FTP server:
Enter the exact path here under which the images are to be stored on the FTP
server.
Alarm sources
You can configure the possible alarm triggers for the VIP (e.g. the alarm inputs).
VIP 10
47
Configuring the Sender
Chapter 6
Video loss alarm:
Select On if the unit is to activate an alarm whenever the video signal is
interrupted.
Contrast alarm:
The VIP can trigger an alarm if the camera image shows too little contrast,
possibly indicating that the lens has been sprayed with paint or covered in some
way. Select On to enable this function.
Motion alarm:
Select On if the unit is to respond to a motion alarm.
Motion detection is configured on a separate page (see page 50).
Alarm input 1 ... Alarm input 2:
Select the option On in order to activate the alarm via the corresponding external
alarm sensor. Otherwise, select Off.
You can choose whether the alarm is triggered by an Active high (contact open)
or Active low (contact closed) input state.
Name:
You can enter a name for each alarm input, which is then displayed next to the
icon for the alarm input on the video live page during the respective configuration
(see page 63).
1./2. SNMP host address:
Enter the IP addresses of up to two chosen receivers here if the alarm message
is to be sent via SNMP-traps.
48
VIP 10
Chapter 6
Configuring the Sender
Alarm connections
You can select a number of options for the response of the VIP to an alarm. In
case of an alarm, the VIP can establish a connection to a predefined IP address
(VCS hardware receiver or PC with receiver software) automatically. You can
enter up to 10 IP addresses which will be selected in sequence by the unit until a
connection is established.
Note
Sender and receiver must share the same subnet for connection set-up
(see page 58).
When assigning the profiles take into account that in case of alarm
connections and auto-connect always Stream 1 is transmitted (see
page 42).
Connect on alarm:
Select On, to establish a connection automatically to a specified IP address in the
event of an alarm.
With the setting Follows input 1, the VIP holds the automatically set up
connection to a remote location as long as an alarm signal is present at the alarm
input 1.
Number of destination address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
VIP 10
49
Configuring the Sender
Chapter 6
Destination IP address:
For each number, enter the corresponding IP address of the desired remote unit.
Destination password:
Enter the password, if the remote unit is protected by a password.
Auto-connect:
Select On if an active connection should be reestablished automatically to one of
the previously specified IP addresses after each restart, e.g. after a connection
breakdown or network dropout.
Motion detector
The VIP has an integrated video sensor which can detect changes in the signal.
Such changes are due primarily to movements in the camera's field of view.
The sensitivity of the video sensor can be adjusted, so an alarm is generated only
if specified values are exceeded.
50
VIP 10
Chapter 6
Configuring the Sender
Note
The video sensor monitors Stream 1. For exact motion detection it is
recommended to choose CIF as video resolution for Stream 1 (see
page 41).
In order for the sensor to function, the following conditions must be met:
] The motion detector must be enabled.
] At least one sensor field must be activated.
] The individual parameters must be set for the operating environment and the
desired responses configured accordingly.
] The sensitivity must be set to a value greater than zero.
Warning!
Reflections of light (off glass surfaces, etc.), switching lights on or off or
changes in the light level caused by cloud movement on a sunny day can
trigger unintended responses from the video sensor and generate false
alarms. Run a series of tests under day and night conditions to ensure that
the sensor works as intended.
For indoor surveillance, ensure constant lighting of the areas during the day
and at night.
Uniform surfaces without contrast can trigger false alarms even with
constant lighting.
Note
Clicking the Defaults button will reset the video sensor to its factory
configuration.
Motion detector
Select On to activate the video sensor.
Select sensor fields
The areas of the image to be monitored by the video sensor can be selected. The
video image is subdivided into 396 square sensor fields. Each of these fields can
be activated or deactivated individually. If it is necessary to exclude particular
regions of the camera's field of view from monitoring due to continuous
movement (by a tree in the wind, etc.), the relevant fields can be deactivated.
VIP 10
51
Configuring the Sender
Chapter 6
– Click Select area to configure the sensor fields. A new window will open.
– If necessary, click Clear all first to clear the current selection (fields marked
red).
– Left-click the fields to be activated. Activated fields are marked red.
– Click Select all to select the entire video frame for monitoring.
– Right-click any fields you wish to deactivate. "Inactive" fields are marked white.
– Click Set to save the configuration.
– Click the close button (X) in the window title bar to close the window without
saving the changes.
Local sensitivity
The basic sensitivity of the video sensor can be adjusted for the environmental
conditions to which the camera is subject.
The sensor reacts to variations in the brightness of the video image. The darker
the observation area, the higher the value that must be selected.
– Adjust the sensitivity by dragging the scroll thumb to the desired setting.
Average (n frames)
You can define the number of frames for which a movement is monitored before
generating an alarm. This helps prevent false alarms from events such as a bird
flying across the surveillance area.
– Select the value by dragging the scroll thumb to the desired position.
Object min size (n*n blocks)
You can specify the number of sensor fields that a moving object must cover to
generate an alarm. This is to prevent objects that are too small from triggering an
alarm.
A minimum value of 2 (2 × 2 sensor fields) is recommended.
– Select the value by dragging the scroll thumb to the desired position.
52
VIP 10
Chapter 6
Configuring the Sender
Motion indicator
To prevent false alarms, a threshold can be applied to the motion signal. This
allows effects such as the background noise from the camera itself to be filtered
out.
The blue line in the illustration represents the alarm threshold. Any value above
this level will trigger an alarm. The parts of the motion signal line which will cause
an alarm are shown in red. The alarm threshold can be set higher or lower to suit
your needs.
– Observe the amplitude of the displayed movement signal over a longer period
of time under all the lighting conditions that may be encountered.
– Move the pointer over the blue line.
– Press the left mouse button in and drag the line to the desired level.
Motion tracking
In some situations you may want an alarm triggered only if movement takes place
in a particular direction. In such cases, enable motion detection and select the
direction of movement required to trigger an alarm.
– Select On to enable the motion tracking feature of the video sensor.
Tracker
The Tracker field shows an arrow indicating the current motion vector in the
video image. The checkboxes at the corners of the field are used to select the
directions to monitor. For example, if all movements toward the left and up are to
trigger an alarm, mark the top left corner. If all movement to the left is to trigger
an alarm, mark the upper left and the lower left checkboxes.
– Observe the movement in the video image indicated by the arrow over a longer
period of time at all the relevant light levels.
– Mark the checkboxes to activate the corresponding directional components for
monitoring.
VIP 10
53
Configuring the Sender
Chapter 6
Relay
You can configure the switching behavior of the relay output. Relay action can be
specified either as open switch (normally closed contact) or closed switch
(normally open contact).
It is also possible to specify whether the output signal should be bistable or
monostable. With bistable operation, the relay remains in the activated state.
With monostable operation, the delay time can be selected after which the relay
reverts to its idle state.
You can choose various events that activate the output automatically. Thus, for
example, it is possible to switch on a spotlight in response to a motion alarm and
switch it off again when the alarm situation is no longer active.
Idle state:
Select Open if the relay is to operate as a normally open contact or Closed if it
is to operate as a normally closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a light switched on by an alarm is to remain lit when the alarm has
ended, select Bistable. If an audible signal activated by an alarm is to sound for
a period of ten seconds for example, select 10 sec.
54
VIP 10
Chapter 6
Configuring the Sender
Relay follows:
Select a particular event to trigger the relay. The following events can activate the
relay:
] Off
No relay triggering by events
] Connection
Triggering caused whenever a connection is established
] Video alarm
Triggering caused by loss of the video signal
] Motion alarm
Triggering caused by the motion alarm
] Local input 1
Triggering caused by the alarm input 1
] Remote input 1
Triggering caused by a relay contact at the target location (only when a
connection is established)
] Contrast alarm
Triggering caused by a lack of contrast in the picture
Relay name:
A name can be assigned to the relay in this field. The name will be shown on the
button under Trigger relay. The Livepage can also be configured to display the
name next to the relay icon.
Trigger relay:
Click the button to switch the relay manually (for example for test purposes or to
operate a door opener).
VIP 10
55
Configuring the Sender
Chapter 6
COM1
The RS232/485serial interface port can be configured to meet your requirements.
Serial port function:
Select a controllable device from the list. If you want to use the serial interface to
transmit transparent data, select Transparent. To operate the VIP with a
terminal, choose Terminal.
Note
After selecting a unit, the remaining parameters in the window are set
automatically and should not be altered.
Camera ID:
If necessary, adjust the ID for the peripheral device that is to be controlled (e.g.
dome camera or PTZ).
Baud rate:
Select the value for the data communication rate in Bit/s.
56
VIP 10
Chapter 6
Configuring the Sender
Data bits:
The number of data bits per character cannot be changed.
Stop bits:
Select the number of stop bits per character.
Parity check:
Select the type of parity check.
Interface mode:
Select the desired protocol for the serial interface.
Half-duplex mode:
Choose the setting appropriate for your application.
Network
The settings on this page are used to integrate the unit into an existing network.
VIP 10
57
Configuring the Sender
Chapter 6
Warning!
Changes to the IP address, subnet mask or gateway address are sent to
the unit when the Set button is clicked. However, they only take effect after
the unit is restarted!
– Click Set after entering a new IP address.
– Enter the old IP address in the address field of the Web browser and append
/reset to it (e.g. 192.168.0.1/reset). The VIP will be restarted after
which it can only be accessed at the new IP address.
Unit IP address:
Enter the desired IP address for the VIP in this field. The IP address must be valid
for the network.
Subnet mask:
Enter the subnet mask corresponding to the inserted IP address here.
Gateway IP address:
Enter the IP address of the gateway here if the unit is to establish a connection
to a unit that is in another subnet. Otherwise, this field can remain empty (0.0.0.0).
Video/audio transmission:
If the device is used in front of a firewall, TCP (HTTP port) should be selected as
the transmission protocol. For use in a local network, choose UDP.
Warning!
Multicast operation is possible only with the UDP protocol. The TCP
protocol does not support multicast connections.
Note
In UDP mode the MTU is 1514 bytes.
58
VIP 10
Chapter 6
Configuring the Sender
Ethernet link type:
If the VIP is connected to the network via a switch, both devices must be set for
the same type of network connection. If necessary, ask your network
administrator about the switch setting.
The value can be set to 10 or 100 MBit/s and full or half-duplex mode (FD or HD)
or to Auto for an autosensing network connection.
Warning!
Errors such as picture interference can occur if the network is not suitable
for transmission of the maximum data rate generated by the VIP.
Dynamic DNS server IP address:
When operating a unit over the Internet, an address pool with dynamic addresses
is used for greater efficiency. This means that the unit is assigned an IP address
each time a connection is made and this address varies. In this case, access is
easier if the unit is listed on a DNS server. It will contact the server at regular
intervals and register its unit name and IP address. To connect to the VIP via the
Internet, it is enough to enter the unit name and the URL of the DNS server. The
server returns the current Internet IP address for the connection.
You can use the DNS server of VCS videotec.info as DNS server. The
associated IP address is 195.145.107.78. The VIP contacts this server
automatically if the desired refresh interval is entered for the next parameter. If
the unit name is MyVIP for example, the URL MyVIP.videotec.info can be
entered in the browser to make a connection.
Dynamic DNS contact interval:
Enter the desired update interval in seconds.
VIP 10
59
Configuring the Sender
Chapter 6
Multicasting
In addition to a 1:1 connection between an encoder and a single receiver
(unicast), the VIP can enable multiple receivers to receive the video signal from
an encoder simultaneously. This is achieved either by duplicating the data stream
in the unit with subsequent distribution to multiple receivers (multi-unicast) or by
distribution of a single data stream over the network to a number of receivers in
a defined group (multicast). A dedicated multicast address and port can be
specified for each of the three encoders.
Note
The prerequisite for multicast operation is a multicast-capable network
using the UDP and IGMP protocols. Other group membership protocols are
not supported. The TCP protocol does not support multicast connections.
When the multicast address is set to 0.0.0.0, the respective encoder operates in
multi-unicast mode (copies the data streams on the unit).
If a valid multicast address is entered the respective encoder operates in the
multicast mode (duplication of the data stream on the network).
Note
Duplication of the data on the unit for multi-unicast connections requires
considerable processor power and, under certain circumstances, leads to
limitations in the picture quality.
Multicast streaming
Select the option MPEG-4 to enable multicast streaming. Off disables multicast
streaming.
60
VIP 10
Chapter 6
Configuring the Sender
Multicast address MPEG-4 encoder 1 (2):
A special IP address (class D address) must be configured for multicast operation
in a multicast-enabled network.
The network must support group IP addresses and the Internet Group
Management Protocol (IGMP). The address range is from 224.0.1.0 to
238.255.255.255.
The multicast address can be the same for multiple encoders. Then however it is
necessary to use a different port in each case so that multiple data streams are
not sent simultaneously over the same port and multicast address.
Enter the multicast address for the particular encoder here if multicast is to be
used.
Port:
In the case of simultaneous data streams from more than one encoder with the
same multicast address the data streams must be assigned to different ports.
Enter the port address for the particular encoder here.
Multicast audio port (G.711):
If audio is to be transmitted in multicast mode, too, the audio data must be
assigned to another port as it is a separate data stream.
Enter the port address for the audio stream here.
Note
A separate audio stream is only transmitted if the corresponding function on
the Audio stream page is enabled (see page 45).
Multicast packet TTL:
This value determines the "life span" of multicast packets on the network. If
multicast is operated via a router, the value must be greater than 1 to ensure that
the packets are passed on.
VIP 10
61
Configuring the Sender
Chapter 6
Version information
The hardware and firmware version numbers are for information only and cannot
be altered. Keep a record of these numbers in case technical assistance is
required.
Hardware version:
The hardware version number of the VIP is displayed.
Firmware version:
The firmware version number of the VIP is displayed.
62
VIP 10
Chapter 6
Configuring the Sender
Livepage configuration
In this dialog, the appearance of the Livepage can be set up to suit your
requirements. Options are provided here to display various information and
operating elements in addition to the video image.
Moreover, individual background graphics can be used for the main window and
for the upper area of the window (banner).
Note
Either GIF or JPEG images can be used. The file paths must correspond to
the access mode (local paths such as C:\Images\Logo.gif for local
files and URLs such as http://www.vcs.com/images/logo.gif for
files on the Internet).
Please note for access via Internet/intranet that there must be a connection
in order to display the image. The image files are not stored on the VIP.
– Mark the checkboxes for the information to be displayed on the Livepage. The
selected elements are marked.
VIP 10
63
Configuring the Sender
Chapter 6
– Check the display of the desired information on the Livepage.
Background URL:
Enter the path to a suitable background graphic in this field. The image can be
stored on a local computer, a local network or at an Internet address.
– Click Search if necessary to find a suitable image on the local network.
Logo URL:
Enter here the path for a suitable image for the upper part of the window (banner).
The image can be stored on a local computer, a local network or at an Internet
address.
– Click Search if necessary to find a suitable image on the local network.
Note
To restore the original graphics, just delete the entries in the fields
Background URL and Logo URL.
Show MPEG-4 live video from:
Select a stream for the MPEG-4 video image on the Livepage. MPEG-4
Encoder 1 is equivalent to Stream 1.
Show alarm inputs:
Alarm inputs are displayed next to the video image as icons along with their
assigned names. If an alarm is active the corresponding icon changes color.
Show relay output:
The relay output is displayed next to the video image as icon along with its
assigned name. If the relay is active the corresponding icon changes color.
Show event log:
The event log will be displayed with date and time in a field under the video
image.
64
VIP 10
Chapter 6
Configuring the Sender
Show system log:
The system log will be displayed with date and time in a field under the video
image and provide information about connections, etc.
Panorama (Sony camera only):
Selecting this option enables the display of a panoramic image. The panoramic
image is shown in the upper part of the browser window. It consists of five single
images that can be updated any time (see page 92).
Note
The panoramic image facility is only available with Sony EVI-D100 or EVID30/31 cameras.
Save event log:
Select this option to save the event log in a text file on the local computer.
These logs can be viewed, edited and printed with any software that can work
with text files (such as Microsoft Word or Excel).
Save system log:
Select this option to save the system log to a text file on the local computer.
These logs can be viewed, edited and printed with any software that can work
with text files (such as Microsoft Word or Excel).
Path for event log:
Enter full path for the event log file.
– If necessary, click Search to find a suitable folder.
Path for system log:
Enter full path for the system log file.
– If necessary, click Search to find a suitable folder.
VIP 10
65
Configuring the Sender
Chapter 6
Path for JPEG and MPEG files:
Enter the full path for saving snapshots and video sequences to be saved from
the Livepage.
– If necessary, click Search to find a suitable folder.
Firmware and configuration upload
Firmware update:
The VIP is designed in such a way that its functions and parameters can be
updated with firmware. To accomplish this, the current firmware is loaded on the
unit via the selected network. It will be installed automatically after the connection
is closed.
Thus a VIP unit can be serviced and updated remotely without requiring a
technician to make changes on-site.
The current firmware can be obtained from VCS Customer Service or
downloaded from the Internet at our Web site (www.vcs.com).
Warning!
Before starting the firmware upload, be sure that you have selected the
correct file! Uploading the wrong files can result in the unit no longer being
addressable, requiring it to be replaced.
Do not interrupt the firmware installation for any reason! Interruption will
damage the flash EPROMs. This can also result in the unit no longer being
addressable, requiring it to be replaced.
– First, save the update file to the hard disk.
66
VIP 10
Chapter 6
Configuring the Sender
– Enter the full path for the update file in the field or click Durchsuchen... to
locate and select the file.
– Click Upload to begin transmission to the unit. Transmission progress can be
monitored from the progress bar.
After the upload is completed, the new firmware will be decompressed and used
to reprogram the flash EPROM. The time necessary is indicated by the message
going to reset Reconnecting in ... seconds.
After the upload is completed successfully, the unit will restart automatically.
If the operating status LED is red, the upload has failed and must be done again.
This requires that you work from a special page:
– Enter the IP address of the unit in the browser and append /main.htm (for
example 192.168.0.12/main.htm).
– Repeat the upload.
Configuration download:
The VIP configuration data can be saved on a computer and the saved data
loaded on a unit from the computer.
– Click Download. A dialog will appear.
– Follow the instructions to save the current settings.
Configuration upload:
– Enter the full path of the file to upload or click Durchsuchen... to select the
desired file.
– Make sure that the file to be loaded originates from the same type of device as
the unit you want to reconfigure.
– Click Upload to begin transmitting the file to the unit. Transmission progress
can be monitored from the progress bar.
After the upload is completed, the new configuration will be activated. The time
necessary is indicated by the message going to reset Reconnecting in ...
seconds.
After the upload is completed successfully, the unit will restart automatically.
VIP 10
67
Configuring the Sender
Chapter 6
Function test
The VIP offers a number of configuration options. Therefore you should check
that it works properly after installation and configuration.
This is the only way to ensure that the VIP will function as intended in an alarm
situation.
Check for the following functions (among other things):
] Can the VIP be dialed remotely?
] Does the VIP transmit all the data required?
] Does the VIP respond as configured to alarm events?
] Is it possible to control peripheral devices if necessary?
68
VIP 10
Configuring the Receiver
7
Basics
The VIP offers various configuration options. Configuration in Expert Mode with
a Web browser is described below. Basic information about configuration with a
Web browser and other configuration options are described in Chapter 5 of this
user guide.
Unit identification
The unit can be assigned a name and an ID to facilitate identification. Both make
the task of managing video surveillance systems with VIDOS von VCS or other
tools much simpler.
Unit name:
Enter a name for the unit here.
Unit ID:
Each VIP should be assigned a unique identifier that can be entered here as an
additional means of identification.
VIP 10
69
Configuring the Receiver
Chapter 7
Password
A VIP unit is generally protected by password to prevent unauthorized access.
You can limit the scale of access by choosing between different authorization
levels.
Note
Correct password protection is only granted when all higher levels of
authorization are also protected by password. If a user password is
assigned a service password must be assigned, too. Therefore assign
passwords always beginning with the highest authorization level.
User name:
The receiver operates with two user names: service and user which refer to
different authorization levels.
The user name service refers to the highest authorization level. Logged in under
service, you can use all functions of the VIP and change all settings.
The user name user refers to the medium authorization level. Logged in under
user, you can connect the unit to a sender on the network and close the
connection, but no changes can be made to the configuration.
Password:
You can define and change a unique password for each user name if you are
logged on as service or if the unit is not protected by a password.
Enter a password for the chosen user name here.
Confirm password:
Re-enter the new password to prevent typing mistakes.
70
VIP 10
Chapter 7
Configuring the Receiver
Note
The new password becomes effective only after you have clicked Set.
Therefore click Set immediately after having entered and confirmed the
password even if you want to assign a password to another user name, too.
Language
If more convenient, a different operating interface language can be chosen.
Website language:
Select the required language from the dropdown field.
Date and time
If a number of VIP units are part of a system, it is important that the internal clocks
of these separate units be synchronized. Only if all units operate with the same
time it is possible, for example, to correctly identify and evaluate recordings that
have been made simultaneously.
Date format:
Choose the desired date format here
(Europe: DD.MM.YYYY; USA: MM.DD.YYYY; Japan: YYYY/MM/DD).
VIP 10
71
Configuring the Receiver
Chapter 7
Unit date:
Enter the current date here. Since the system time is controlled by the internal
clock, it is not necessary to enter the day of week. This is added automatically.
Unit time:
Enter the current time here or click the Synchr. PC button to copy the system
time of your computer to the VIP.
Time server
Using the Time Server Protocol the VIP can receive a time signal from a time
server and use it to set its internal clock. The device calls up the time signal
automatically every two hours.
Time zone:
Select the time zone that applies to your system.
Time settings:
Select this during daylight savings time if the time change is to be taken into
account. Deselect it when standard time has resumed.
Time server IP address:
Enter the IP address of the chosen time server here.
72
VIP 10
Chapter 7
Configuring the Receiver
MPEG decoder
The monitor can be assigned a name to facilitate identification. The video output
standard for the connected monitor can also be selected here.
The VIP can monitor the incoming data stream for integrity and can display a
notification text on the monitor when it has detected disturbances in the
transmission.
Monitor name:
Enter the desired monitor name here. The monitor name is used for easier
identification of the monitor in large systems, e.g. it is displayed in VIDOS, the
VCS software for managing video surveillance systems.
Enter a unique, unambiguous name.
Video output standard:
Select the video standard for the monitor output.
Warning!
Be sure to choose the correct video standard to avoid damaging the
monitor.
Display transmission disturbance:
Choose On to display a text on the monitor in case of transmission disturbances.
VIP 10
73
Configuring the Receiver
Chapter 7
Disturbance sensitivity level:
Here you can define at what level the text display is triggered. The lower the value
the higher the sensitivity level of the VIP.
Notification text:
Enter the text that is to be displayed on the monitor. It can contain up to 31
characters.
Audio stream
In addition to video data, the unit can also send and receive audio signals. The
transmission of audio takes place at the same time as that of the video data in a
separate data stream. Thus it increases the data traffic. The audio data is coded
according to G.711 compression standard and requires an additional bandwidth
of about 80 kBit/s per direction.
Note
Sending of audio signals via the receiver is only possible if the audio
function of the sender is enabled (see page 74) and the checkbox Include
audio on the Decoder connection page is activated (see page 97).
Enable audio:
To transmit a separate G.711 audio stream choose On.
74
VIP 10
Chapter 7
Configuring the Receiver
Alarm sources
Both VIP decoder alarm inputs can be configured individually.
Alarm input 1 ... Alarm input 2:
Select the option On in order to activate the alarm via the corresponding external
alarm sensor. Otherwise, select Off.
You can choose whether the alarm is triggered by an Active high (contact open)
or Active low (contact closed) input state.
Name:
You can enter a name for each alarm input.
1./2. SNMP host address:
Enter the IP addresses of up to two chosen receivers here if the alarm message
is to be sent via SNMP-traps.
VIP 10
75
Configuring the Receiver
Chapter 7
Alarm connections
You can select a number of options for the response of the VIP to an alarm. In
case of an alarm, the VIP can establish a connection to a predefined IP address,
e.g. a VIP sender, automatically. You can enter up to 10 IP addresses which will
be selected in sequence by the unit until a connection is established.
Note
Sender and receiver must share the same subnet for connection set-up
(see page 81).
If the VIP connects to a "dual streaming“ encoder Stream 1 will be
transmitted.
Connect on alarm:
Select On, to establish a connection automatically to a specified IP address in the
event of an alarm.
With the setting Follows input, the VIP holds the automatically set up connection
to a remote location as long as an alarm signal is present at its alarm input 1. You
can use this setting to establish a connection between two VIP units via a
connected on-off switch. In this case you don’t need a computer to set up the
connection.
Number of destination IP address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
76
VIP 10
Chapter 7
Configuring the Receiver
Destination IP address:
For each number, enter the corresponding IP address of the desired remote unit.
Destination password:
Enter the password, if the remote unit is protected by a password.
Remote encoder line:
If the remote unit is a multi-channel device enter here the number of the video
input which is to be the data source.
Auto-connect:
Select On if an active connection should be reestablished automatically to one of
the previously specified IP addresses after each restart, e.g. after a connection
breakdown or network dropout.
Relay
You can configure the switching behavior of the relay output. Relay action can be
specified either as open switch (normally closed contact) or closed switch
(normally open contact).
It is also possible to specify whether the output signal should be bistable or
monostable. With bistable operation, the relay remains in the activated state.
With monostable operation, the delay time can be selected after which the relay
reverts to its idle state.
VIP 10
77
Configuring the Receiver
Chapter 7
You can choose various events that activate the output automatically. Thus, for
example, it is possible to switch on a spotlight in response to a motion alarm and
switch it off again when the alarm situation is no longer active.
Idle state:
Select Open if the relay is to operate as a normally open contact or Closed if it
is to operate as a normally closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a light switched on by an alarm is to remain lit when the alarm has
ended, select Bistable. If an audible signal activated by an alarm is to sound for
a period of ten seconds for example, select 10 sec.
Relay follows:
Select a particular event to trigger the relay. The following events can activate the
relay:
] Off
No relay triggering by events
] Connection
Triggering caused whenever a connection is established
] Local input 1
Triggering caused by the alarm input 1
] Remote input 1
Triggering caused by a relay contact at a remote location (only when a
connection is established)
Relay name:
A name can be assigned to the relay in this field. The name will be shown on the
button under Trigger relay.
78
VIP 10
Chapter 7
Configuring the Receiver
Trigger relay:
Click the button to switch the relay manually (for example for test purposes or to
operate a door opener).
COM1
The RS232/485serial interface port can be configured to meet your requirements.
Serial port function:
If you want to use the serial interface to transmit transparent data, select
Transparent. To operate the VIP with a terminal, choose Terminal.
Note
After selecting an interface function, the remaining parameters in the
window are set automatically and should not be altered.
Camera ID:
If necessary, adjust the ID for the peripheral device that is to be controlled (e.g.
dome camera or PTZ).
VIP 10
79
Configuring the Receiver
Chapter 7
Baud rate:
Select the value for the data communication rate in Bit/s.
Data bits:
The number of data bits per character cannot be changed.
Stop bits:
Select the number of stop bits per character.
Parity check:
Select the type of parity check.
Interface mode:
Select the desired protocol for the serial interface.
Half-duplex mode:
Choose the setting appropriate for your application.
Network
The settings on this page are used to integrate the unit into an existing network.
80
VIP 10
Chapter 7
Configuring the Receiver
Warning!
Changes to the IP address, subnet mask or gateway address are sent to
the unit when the Set button is clicked. However, they only take effect after
the unit is restarted!
– Click Set after entering a new IP address.
– Enter the old IP address in the address field of the Web browser and append
/reset to it (e.g. 192.168.0.1/reset). The VIP will be restarted after
which it can only be accessed at the new IP address.
Unit IP address:
Enter the desired IP address for the VIP in this field. The IP address must be valid
for the network.
Subnet mask:
Enter the subnet mask corresponding to the inserted IP address here.
Gateway IP address:
Enter the IP address of the gateway here if the unit is to establish a connection
to a unit that is in another subnet. Otherwise, this field can remain empty (0.0.0.0).
Video/audio transmission:
If the device is used in front of a firewall, TCP (HTTP port) should be selected as
the transmission protocol. For use in a local network, choose UDP.
Warning!
Multicast operation is possible only with the UDP protocol. The TCP
protocol does not support multicast connections.
Note
In UDP mode the MTU is 1514 bytes.
VIP 10
81
Configuring the Receiver
Chapter 7
Ethernet link type:
If the VIP is connected to the network via a switch, both devices must be set for
the same type of network connection. If necessary, ask your network
administrator about the switch setting.
The value can be set to 10 or 100 MBit/s and full or half-duplex mode (FD or HD)
or to Auto for an autosensing network connection.
Warning!
Errors such as picture interference can occur if the network is not suitable
for transmission of the maximum data rate generated by the VIP.
Dynamic DNS server IP address:
When operating a unit over the Internet, an address pool with dynamic addresses
is used for greater efficiency. This means that the unit is assigned an IP address
each time a connection is made and this address varies. In this case, access is
easier if the unit is listed on a DNS server. It will contact the server at regular
intervals and register its unit name and IP address. To connect to the VIP via the
Internet, it is enough to enter the unit name and the URL of the DNS server. The
server returns the current Internet IP address for the connection.
You can use the DNS server of VCS videotec.info as DNS server. The
associated IP address is 195.145.107.78. The VIP contacts this server
automatically if the desired refresh interval is entered for the next parameter. If
the unit name is MyVIP for example, the URL MyVIP.videotec.info can be
entered in the browser to make a connection.
Dynamic DNS contact interval:
Enter the desired update interval in seconds.
82
VIP 10
Chapter 7
Configuring the Receiver
Version information
The hardware and firmware version numbers are for information only and cannot
be altered. Keep a record of these numbers in case technical assistance is
required.
Hardware version:
The hardware version number of the VIP is displayed.
Firmware version:
The firmware version number of the VIP is displayed.
Firmware and configuration upload
Firmware update:
The VIP is designed in such a way that its functions and parameters can be
updated with firmware. To accomplish this, the current firmware is loaded on the
unit via the selected network. It will be installed automatically after the connection
is closed.
Thus a VIP unit can be serviced and updated remotely without requiring a
technician to make changes on-site.
VIP 10
83
Configuring the Receiver
Chapter 7
The current firmware can be obtained from VCS Customer Service or
downloaded from the Internet at our Web site (www.vcs.com).
Warning!
Before starting the firmware upload, be sure that you have selected the
correct file! Uploading the wrong files can result in the unit no longer being
addressable, requiring it to be replaced.
Do not interrupt the firmware installation for any reason! Interruption will
damage the flash EPROMs. This can also result in the unit no longer being
addressable, requiring it to be replaced.
– First, save the update file to the hard disk.
– Enter the full path for the update file in the field or click Durchsuchen... to
locate and select the file.
– Click Upload to begin transmission to the unit. Transmission progress can be
monitored from the progress bar.
After the upload is completed, the new firmware will be decompressed and used
to reprogram the flash EPROM. The time necessary is indicated by the message
going to reset Reconnecting in ... seconds.
After the upload is completed successfully, the unit will restart automatically.
If the „operating status“ LED is red, the upload has failed and must be done again.
This requires that you work from a special page:
– Enter the IP address of the unit in the browser and append /main.htm (for
example 192.168.0.12/main.htm).
– Repeat the upload.
Configuration download:
The VIP configuration data can be saved on a computer and the saved data
loaded on a unit from the computer.
– Click Download. A dialog will appear.
– Follow the instructions to save the current settings.
84
VIP 10
Chapter 7
Configuring the Receiver
Configuration upload:
– Enter the full path of the file to upload or click Durchsuchen... to select the
desired file.
– Make sure that the file to be loaded originates from the same type of device as
the unit you want to reconfigure.
– Click Upload to begin transmitting the file to the unit. Transmission progress
can be monitored from the progress bar.
After the upload is completed, the new configuration will be activated. The time
necessary is indicated by the message going to reset Reconnecting in ...
seconds.
After the upload is completed successfully, the unit will restart automatically.
VIP 10
85
Configuring the Receiver
Chapter 7
Function test
The VIP offers a number of configuration options. Therefore you should check
that it works properly after installation and configuration.
This is the only way to ensure that the VIP will function as intended in an alarm
situation.
Check for the following functions (among other things):
] Can the VIP be dialed remotely?
] Does the VIP transmit all the data required?
] Does the VIP respond as configured to alarm events?
] Is it possible to control peripheral devices if necessary?
86
VIP 10
Sender Operation
8
Operation with Microsoft Internet Explorer
A computer with Microsoft Internet Explorer (version 5.5 or later) can be used to
receive live images from the VIP, control cameras or other peripherals and replay
sequences stored on the local hard drive.
Note
Make sure the graphic card is set to 16 or 32 bit color depth and the
Microsoft Virtual Machine is installed and active on your computer. If
necessary, the required software and controls can be installed from the CD
provided (see the list of components supplied, page 11).
Instructions for using the Web browser will be found in its online help.
System requirements
] Microsoft Internet Explorer (version 5.5 or higher)
] Monitor resolution 1024 × 768 pixels
] Network access (intranet or Internet)
MPEG-ActiveX installation
Note
In order to display the live video images, an appropriate MPEG-ActiveX
must be installed on the computer, such as that used for playing DVD
movies. If necessary, the required software and controls can be installed
from the CD provided (see the list of components supplied, page 11).
– Insert the CD into the CD-ROM drive of the computer. The CD will start
automatically. If the CD does not start automatically, open the root directory of
the CD in Windows Explorer and double click MPEGAx.exe.
– Follow the instructions on the screen.
VIP 10
87
Sender Operation
Chapter 8
Establishing the connection
The VIP must be provided with a valid IP address to operate on your network.
The following default address has been pre-set at the factory: 192.168.0.1
– Start the Web browser.
– Enter the IP address of the VIP as the URL. The connection will be
established, and after a short time the Livepage with the video image will
appear.
The Livepage
After the connection is established, the Livepage will be displayed first. It shows
the live video image in the middle of the browser window. Depending upon
configuration, various text overlays may be visible on the image (see page 39).
Other information may also be shown next to the video image on the Livepage.
The display depends on the settings on the configuration page Livepage
configuration (see page 63).
88
VIP 10
Chapter 8
Sender Operation
Note
If the connection cannot be established, this may be because the unit
selected is already busy with another remote station. Depending upon the
network configuration and the individual units, a transmitter can serve up to
five receivers at the same time.
VIP password protection
If the VIP is password-protected against unauthorized access, a password dialog
will appear first.
Note
Configuration work can only be performed on a password-protected VIP
unit if the service user is logged on.
– Enter the user name and the associated password in the appropriate fields.
– Click OK. If the password is entered correctly, the Livepage with the video
image will be shown.
Image quality
The VIP 10 displays either a live video sequence in MPEG-4 format or individual
live video frames in JPEG format.
– Click on the MPEG-4 link in the navigation bar at the top of the browser display
to display or decode the video sequences in the corresponding image format.
or
– Click on the M-JPEG link in the navigation bar at the top of the browser display
to display or decode the individual frames in the corresponding image format.
– Click one of the links (Small or Large) above the live video image to view the
image in the respective resolution.
Alarm inputs
In the event of an alarm, a red alarm symbol for the triggering alarm input is
displayed next to the video image. The display of alarms and other details
depends on the configuration of the unit (see page 47).
VIP 10
89
Sender Operation
Chapter 8
Relay output
Depending upon configuration, a device such as a floodlight or a door opener can
be activated by the relay of the VIP unit. The display of the relay and other details
depends on the configuration of the unit (see page 54).
– Click the relay symbol next to the video image to activate the relay output. The
symbol will turn red when the relay is activated.
Event messages
The Event log field is where events such as switching a relay or alarm status
messages are listed. These messages can be saved automatically in a log file
(see page 65).
System messages
The System log field contains information about the operating status of the VIP
and the connection. These messages can be saved automatically in a log file
(see page 65).
Audio function
Depending upon configuration (see page 44) audio data can be send and
received by the VIP. All users that are connected via Web browser receive the
audio data sent by the VIP.
Only the user who has set up the first browser connection can send audio data to
the unit.
– Klick on the Livepage anywhere outside the video picture to take the focus off
the ActiveX.
– Keep the key F12 pressed to send audio data to the VIP. In the browser status
bar the message Send Audio ON is shown.
– Release the key F12 if you want to stop sending audio data to the VIP. In the
browser status bar the message Send Audio OFF is shown.
Note
When the browser connection over which audio data can be sent to the unit
is cut off this function is taken over by the connection that is set up next.
90
VIP 10
Chapter 8
Sender Operation
Control functions
Control options for peripheral devices (such as a pan and tilt head or a dome
camera) depend on the type of device installed and the configuration of the VIP.
If a controllable device is connected to the VIP and configured, the controls for
the peripheral are displayed next to the video image, here e.g. for a Sony EVID30/31.
– To control a peripheral device click the associated operating elements.
– Move the pointer over the video image. Further options for peripheral device
control will be displayed using the pointer.
VIP 10
91
Sender Operation
Chapter 8
Panorama view
If you are working with a Sony EVI-D100 or EVI-D30/31 camera, you can also
display a panoramic image. The panoramic image is shown in the upper part of
the Livepage. It consists of five single images that can be updated any time.
– Right-click on the panoramic image to open the context menu.
– Select Start scan to update the individual images. Stop scan cancels the
update.
Note
The panorama image is displayed only if Show panorama view is selected
on the configuration page Livepage configuration (see page 63).
92
VIP 10
Chapter 8
Sender Operation
Saving snapshots
Individual images from the current video sequence on the Livepage can be saved
on the computer hard drive in JPEG format.
– Click the Snapshot icon. The image will be saved. The storage location
depends on the configuration of the VIP (see page 66).
Image resolution
Snapshots can be called up and displayed at different resolutions by entering
URL parameters in the address field of the Web browser. Just append the
corresponding parameter to the snap.jpg command:
] snap.jpg?JpegSize=S
for 176 × 144 pixels (QCIF)
] snap.jpg?JpegSize=M
for 352 × 288 pixels (CIF)
] snap.jpg?JpegSize=XL for 704 × 576 pixels (4CIF)
Without the extra parameter, the default image size is 352 × 288 (CIF) pixels.
– Type the IP address of the VIP, followed by /snap.jpg into the Internet
address field as URL (e.g. http://192.168.0.12/snap.jpg).
– Press the Return key or Enter key. A single frame image will be displayed in a
new window.
– Right-click the image and select Save Picture As... from the context menu.
– Save the snapshot in the desired format, giving it a new name.
VIP 10
93
Sender Operation
Chapter 8
Recording video sequences
Segments from the current video sequence on the Livepage can be saved on the
computer hard drive in MPEG format.
Click the MPEG-sequence icon. Saving begins immediately. The storage
location depends on the configuration of the VIP (see page 66). A recording in
progress is indicated by the blinking of the red dot on the icon.
– Click the MPEG-sequence icon again. Saving will be terminated.
Image resolution
The sequences will be recorded at the resolution specified in the encoder settings
(see page 41). Select the stream for Livepage video display on the configuration
page Livepage configuration (see page 64).
MPEG-Viewer installation
You can display recorded video sequences with the VCS MPEG-Viewer which
you find on the accompanying software CD (see page 11).
– Insert the CD into the CD-ROM drive of the computer. The CD will start
automatically.If the CD does not start automatically, open the root directory of
the CD in Windows Explorer.
– Open the directory entitled MPEG-Viewer and copy the MPEGViewer.exe file
to your hard drive.
– You can start the MPEG-Viewer by double-clicking the file
MPEGViewer.exe.
94
VIP 10
Receiver Operation
9
Operation with Microsoft Internet Explorer
A computer with Microsoft Internet Explorer (version 5.5 or later) can be used to
set up a connection to a VCS sender and to display the live images received on
a monitor.
Note
Make sure the graphic card is set to 16 or 32 bit color depth and the
Microsoft Virtual Machine is installed and active on your computer. If
necessary, the required software and controls can be installed from the CD
provided (see the list of components supplied, page 11).
Instructions for using the Web browser will be found in its online help.
System requirements
] Microsoft Internet Explorer (version 5.5 or higher)
] Monitor resolution 1024 × 768 pixels
] Network access (intranet or Internet)
MPEG-ActiveX installation
Note
In order to display the live video images, an appropriate MPEG-ActiveX
must be installed on the computer, such as that used for playing DVD
movies. If necessary, the required software and controls can be installed
from the CD provided (see the list of components supplied, page 11).
– Insert the CD into the CD-ROM drive of the computer. The CD will start
automatically. If the CD does not start automatically, open the root directory of
the CD in Windows Explorer and double click MPEGAx.exe.
– Follow the instructions on the screen.
VIP 10
95
Receiver Operation
Chapter 9
Establishing the connection
The VIP must be provided with a valid IP address to operate on your network.
The following default address has been pre-set at the factory: 192.168.0.2
– Start the Web browser.
– Enter the IP address of the VIP as the URL. The connection will be
established, and after a short time the Decoder connection page will appear.
The Decoder connection page
After the connection has been established, the Decoder connection page will be
displayed and the unit automatically scans the network for available senders.
Preview
In this area you can select one of the video sources found in the network. A
snapshot of the video image from the selected video source is displayed. In
addition to the unit name the snapshot provides other means of identifying the
sender.
96
VIP 10
Chapter 9
Receiver Operation
Monitor
As soon as a connection with a sender is established, you will see a snapshot of
the video image from the connected sender here.
Connection between the receiver and sender
During startup the VIP automatically scans the network for available senders. As
soon as a sender is found on the network, the VIP automatically displays a
snapshot of this sender. All the senders found are listed in a dropdown list labeled
Video sources.
Establishing a connection
– Choose a sender from the list of Video sources. A JPEG snapshot from the
video source selected will appear on the start page under Preview.
– Mark the checkbox Include audio if you want to transmit audio, too. Make
sure for correct audio transmission configuration for both, sender and receiver.
– Mark the checkbox Include data if you want to transmit transparent data, too.
Make sure for correct data transmission configuration for both, sender and
receiver.
Note
The checkboxes must be marked prior to connection set-up in order to
include audio and data transmission.
– Click the corresponding checkbox again to deactivate audio or data
transmission respectively.
– Click the button Connect MPEG-4 to connect the video images to the
connected monitor. Under Monitor a snapshot from the connected source is
displayed.
– If the sender is a multi-channel unit, e.g. a VideoJet 8000 from VCS, you can
choose the Video input to be displayed.
Terminating a connection
– Click the close button (X) in the ’Monitor’-window title bar to stop the video
display on the monitor.
VIP 10
97
Receiver Operation
98
Chapter 9
VIP 10
Hardware Connections
10
Hardware connections between VCS units
A VIP sender, connected to a camera, and a VIP receiver, connected to a
monitor, can be linked together or to other VCS units easily via an Ethernet
network. This makes it possible to establish connections over large distances
with little effort for installation or cabling.
Installation
The VCS units are designed to connect with one another automatically when
correspondingly configured. The only requirement is that they are both part of a
closed network. Proceed as follows to install the units:
– Connect the units to the closed network using Ethernet cables.
– Connect them to the mains supply.
Note
Make sure the units are correctly configured for the network environment
and that the correct IP address of the remote unit that is to be connected in
case of alarm is set on the configuration page Alarm connections (see
page 50 for the sender and page 77 for the receiver).
Establishing the connection
There are three options for establishing a connection between a VCS sender and
a VCS receiver in a closed network:
] when an alarm signal is given,
] using a terminal program or
] using a Web browser
VIP 10
99
Hardware Connections
Chapter 10
Connection when an alarm signal is given
Sender and receiver can be configured to connect automatically with each other
when an alarm is triggered (see page 49 for sender and page 77for receiver).
After a short time, the live video image from the sender will be shown on the
connected monitor.
This option can also be used to connect two VCS units via an on-off switch at the
receiver. In this case, a computer is not needed to establish the connection (see
page 76).
Connection using a terminal program
This operating mode has various prerequisites. Refer to the section Setup using
terminal software (see page 21).
– Start the terminal program. Enter the command i to call up the IP menu.
– Enter the command r in the IP menu to change the remote IP address, then
enter the IP address of the device to connect to.
– Enter the command a in the IP menu to activate automatic connection set up.
Connection using a Web browser
This operating mode has various prerequisites. Refer to the section Establishing
the connection (see page 25).
– Use the Web browser to connect to the VIP receiver. Its home page will be
displayed.
– Establish the desired connection to the monitor (see page 97).
100
VIP 10
Chapter 10
Hardware Connections
Closing the connection
The connection may be closed using a terminal program or Web browser.
Closing the connection using a terminal program
– Start the terminal program (see page 21); enter the command i to call up the
IP menu.
– Enter the command a in the IP menu to deactivate automatic connection.
Closing the connection using a Web browser
– Use the Web browser to connect to the VIP receiver. Its home page will be
displayed.
– Click the icon with the red x to stop the video display on the monitor.
VIP 10
101
102
VIP 10
Operation with Decoder Software
11
Operation with VIDOS
VIP video servers and VIDOS software can be combined to form a highperformance system solution.
VIDOS is software for the operation, control and administration of CCTV
installations (e.g. surveillance systems) at remote locations. It runs under
Microsoft Windows operating systems. Its main function is decoding video, audio
and control data from a remote sender.
There are many options available for operation and configuration when using VIP
devices in combination with VIDOS. Refer to the software documentation for
more details.
VIP 10
103
104
VIP 10
Maintenance and Upgrades
12
Testing the network connection
The ping command can be used to check the connection between two IP
addresses. This allows you to test whether a unit is active in the network.
– Open the DOS command prompt.
– Type ping followed by the IP address of the unit.
If the unit is found, the response appears as Reply from ..., followed by the
number of bytes sent and the transmission time in milliseconds. Any other
response indicates that the unit cannot be accessed via the network. Possible
causes:
] The unit is not properly connected to the network. Check the cable
connections in this case.
] The unit is not correctly integrated into the network. Check the IP address,
subnet mask and, if necessary, the gateway IP.
Device reset
The reset button can be used to reset the unit to its original factory settings. Any
changes in the settings will be overwritten by the factory defaults. This may be
necessary, for example, if the unit has invalid settings that prevent it from
functioning as desired.
Warning!
All configured settings will be discarded during a reset. If necessary, back
up the current settings using the Download button on the configuration
page entitled Firmware and configuration upload (see page 66 for
sender and page 83 for receiver).
Before starting the firmware update, be sure that you have selected the
correct upload file! Uploading the wrong files can result in the unit no longer
being addressable, requiring it to be replaced. Do not interrupt the firmware
installation for any reason! Interruption will damage the Flash EPROM. This
VIP 10
105
Maintenance and Upgrades
Chapter 12
can likewise result in the unit no longer being addressable, requiring it to be
replaced.
Note
After a reset, the unit can only be addressed via the factory default IP
address. The IP address can be changed as described in the chapter
entitled Installation (see page 22).
– If necessary, back up the current settings using the Download button on the
configuration page entitled Firmware and configuration upload (see page
66 for sender and page 83 for receiver).
– Use a pointed object to press the reset button which is found below the USB
interface (see page 16) until the „operating status“ LED blinks red. All settings
will revert to their defaults.
– Change the IP address of the unit as necessary.
– Configure the unit to meet your requirements.
Repairs
Warning!
Never open the casing of the VIP device. The unit does not contain parts
that you can repair or replace.
Ensure that maintenance or repair work is performed only by qualified personnel,
or contact your VCS dealer service center.
Transfer and disposal
The VIP should only be passed on together with this manual.
The unit and its power supply contain environmentally hazardous materials that
must be disposed of according to law.
Defective or superfluous units and parts should be disposed of professionally or
taken to your local collection point for hazardous materials.
106
VIP 10
13
Appendix
Troubleshooting
If you cannot correct a malfunction, please contact your supplier, system
integrator or VCS customer service ([email protected]).
The version numbers of the internal processors can be viewed on a special page.
Please note this information before contacting Customer Service.
– In the address field of the browser, append /version.htm to the IP address
of the unit (e.g. 192.168.0.12/version.htm) and press Enter.
– Write down the information or print out the page.
The following table is intended to help you identify the causes of malfunctions and
correct them where possible.
Problem
Possible Causes
Faulty cable connections.
No connection
between the unit and
terminal program.
The computer's serial
interface is not connected.
Solution
Check all cables, plugs, contacts
and connections.
Check the other serial interfaces.
Interface parameters do not Select a different COM port if
match.
necessary and make sure that the
computer's interface parameters
match those of the unit. You can also
try the following standard
parameters: 19,200 baud, 8 data
bits, no parity, 1 stop bit. After that,
switch off the power to the unit and
switch it on again after a couple of
seconds.
No image
transmission from
the target location.
VIP 10
Defective camera.
Connect a local monitor and check
the camera function.
Faulty cable connections.
Check all cables, plugs, contacts
and connections.
107
Appendix
Chapter 13
Problem
Possible Causes
Solution
No connection
established, no
image transmission.
The unit's configuration.
Check all settings.
Faulty installation.
Check all cables, plugs, contacts
and connections.
Wrong IP address.
Check the IP addresses (terminal
program).
Faulty data transmission
within the LAN.
Check data transmission with the
ping command.
The maximum number of
connections possible to
other devices has already
been reached.
Wait until there is a free connection
and contact the sender again.
No image
transmission to
analog monitor
Transmission data rate to
high for receiver
Reduce transmission data rate at
the sender.
No audio
transmission from
the target location.
Hardware failure.
Check that all audio devices
connected function correctly.
Faulty cable connections.
Check all cables, plugs, contacts
and connections.
Faulty configuration.
Check the audio settings (volume
and coding mode).
Audio/voice communication
is busy with another
receiver.
Wait until a connection is available
and contact the sender again.
No alarm source is chosen.
Select alarm input on the Alarm
sources configuration page.
No alarm action selected.
Define the desired alarm actions on
the Alarm connections
configuration page. If necessary,
change the IP address.
The unit does not
report an alarm.
Control of cameras
or other devices is
not possible.
Check all cable connections and
The cable connection
between the serial interface ensure all plugs are properly
and the connected device is plugged in.
incorrect.
The interface parameters
conflict with those of the
other device connected.
The unit is no longer Incorrect update file.
operational after a
firmware upload.
108
Make sure the settings of all devices
involved are compatible.
Connect the unit via Web browser
typing its IP address followed by
/main.htm and repeat the upload.
VIP 10
Chapter 13
Appendix
LEDs
The VIP video server is equipped with several LEDs that show the operating
status and can give indications of possible malfunctions:
Operating status LED
Not lit:
Device is switched off.
Lit yellow:
Device is switched on.
Lit red (briefly):
Device is starting up.
Lit red (continuously): Device is out of order, upload failed.
Network connection LED
Lit green:
Connected to the network.
Not lit:
Not connected to the network.
Data transfer LED
Blinking orange:
Data transfer via the network.
Not lit:
No data transfer.
VIP 10
109
Appendix
Chapter 13
RS232/485 interface
Options for using the serial interface include transparent data transfer, control of
connected devices or operation of the unit with a terminal program. Depending
on the setting, the interface works with the RS232 or RS422/485 protocol. The
protocol used depends on the current configuration (see page 56).
The pin assignments depend on the protocol used.
Pin
RS232 Protocol
RS422/485 Protocol
1
–
–
2
RxD (receive data)
RxD+ (receive data plus)
3
TxD (transmit data)
TxD- (transmit data minus)
4
–
–
5
GND (ground)
GND (ground)
6
–
–
7
RTS (ready to send)
TxD+ (transmit data plus)
8
CTS (clear to send)
RxD- (receive data minus)
9
–
–
Note
For RS422/RS485 pin assignment is also possible for 2-wire connection.
– Connect the TxD+ with the RxD+. TxD+ then is equivalent to DATA+.
– Connect the TxD- with the RxD-. TxD- then is equivalent to DATA-.
110
VIP 10
Chapter 13
Appendix
Connection jacks
The connection jacks are used to connect to the mains supply. As standard, the
connection to the power supply unit is made here. They also allow the connection
of alarm switches, relays, an audio source and a loudspeaker.
Terminal allocation
Terminal
Function
Li
audio input (line level)
Lo
audio output (line level)
IN1
Alarm 1 input
R
alarm output
+
power supply, 9 to 24 V
GND
electrical ground
GND
electrical ground
IN2
Alarm 2 input
R
alarm output
–
power supply
Each alarm input (IN1 resp. IN2) is to be connected with the electrical ground
(GND) using a trigger contact.
VIP 10
111
Appendix
Chapter 13
Glossary
A few brief explanations of the most important terms and abbreviations used in
the field of communications technology can be found below.
10/100 Base-T
IEEE 802.3 specification for 10 or 100 MBit/s Ethernet
ARP
Address Resolution Protocol: a protocol for mapping MAC
and IP addresses
Baud
Measure for the speed of the data transfer rate
Bit/s
Bits per second, the actual data rate
CIF
Common Intermediate Format, video format with 352 × 288
pixels
DNS
Domain Name Service
FTP
File Transfer Protocol
Full duplex
Simultaneous data transmission in both directions (sending
and receiving)
G.711
Standard ITU-T audio coding algorithms
GOP
Group of pictures
HTTP
Hypertext Transfer Protocol
ICMP
Internet Control Message Protocol
ID
Identification: a machine-readable character sequence
IEEE
Institute of Electrical and Electronics Engineers
IGMP
Internet Group Management Protocol
Internet Protocol
The main protocol used on the Internet. Together with the
Transfer Control Protocol (TCP), it constitutes "TCP/IP"
IP
See "Internet Protocol"
IP address
A 4-byte number uniquely defining each device on the
Internet. It is usually written in dotted decimal notation with
periods separating the bytes, for example "209.130.2.193".
ISDN
Integrated Services Digital Network
JPEG
An encoding process for still images (Joint Photographic
Experts Group)
kBit/s
Kilobits per second, the actual data rate
LAN
See Local area network
Local area network
A communications network serving users within a limited
geographical area, such as a building or a university campus.
It is controlled by a network operating system and uses a
transfer protocol.
M-JPEG
Motion-JPEG; the video sequence is generated stringing
together JPEG-images
112
VIP 10
Chapter 13
Appendix
MAC
Media Access Control
MPEG-4
Video compression standard designed for transmission of
audiovisual data at very low transfer rates (for example via
the Internet).
MTU
Maximum Transmission Unit resp. Maximum Transfer Unit
Netmask
A mask that explains which part of an IP address is the
network address and which part comprises the host address.
It is usually written in dotted decimal notation, for example
"255.255.255.192".
Parameter
Values used for configuration
QCIF
Quarter CIF, a video format with 176 × 144 pixels
RS232/RS422/RS485
Data transfer standards
RTP
Realtime Transport Protocol; transport protocol for video and
audio in real time
SNMP
Simple Network Management Protocol
Subnet mask
See netmask
TCP
Transfer Control Protocol
Telnet
Connection protocol for a user to connect to a remote
computer (host) in the Internet
Time Server Protocol
A protocol to synchronize computers in the Internet
TTT
Time To Live
UDP
User Datagram Protocol
URL
Uniform Resource Locator
UTP
Unshielded Twisted Pair
WAN
See wide area network
Wide area network
A long distance link used to extend or connect remotely
located local area networks
VIP 10
113
Appendix
Chapter 13
VIP 10 Specifications
Operating voltage
12 ... 24 V DC, power supply included
Power consumption
approx. 10 W
Network interface
Ethernet 10/100 Base-T, auto-sensing, half/fullduplex, RJ45
Video data rate
9.6 kBit/s ... 4 MBit/s (MPEG-4)
Audio data rate
80 kBit/s (MPEG-4) per direction
Audio sampling rate
8 kHz (MPEG-4)
Video standards
PAL, NTSC
Image resolution
(PAL/NTSC)
704 × 576/480 pixels (D1/4CIF)
704 × 288 pixels (2CIF)
352 × 576/480 pixels (1/2 D1, adjustable)
352 × 288 pixels (CIF)
176 × 144 pixels (QCIF)
Video coding protocols
MPEG-4; M-JPEG
Audio coding protocol
G.711; 300 Hz to 3.4 kHz
Network protocols
RTP, Telnet, UDP, TCP, IP, HTTP, IGMP, ICMP, ARP,
SNMP
Video input
1 × BNC jack 0.7 ... 1.2 Vpp,
75 Ohm switchable, PAL/NTSC
Video output
1 × BNC jack 1.0 Vpp,
75 Ohm, PAL/NTSC
Audio input
1 × push-in terminal 1.0 Vpp, 50 kOhm, mono
Audio output
1 × push-in terminal 1.0 Vpp, 60 mW, min. 8 Ohm,
mono
Data interfaces
1 × RS232/RS422/RS485, bidirectional,
9-pin Sub-D
1 × USB 1.1
Alarm input
2 × push-in terminal,
max. activation resistance 10 Ohm
Relay output
1 × push-in terminal, 30 Vpp, 1 A
Indicators
3 LEDs (operating status, network connection, data
transfer)
114
VIP 10
Chapter 13
Appendix
Operating conditions
Temperature 0 ... +50°C,
relative humidity 20 ... 80%,
non-precipitating
Approvals & certifications
CE; IEC 60950; UL 1950; AS/NZS 3548;
EN 55103-1, -2; EN 55130-4; EN 55022; EN 55024;
EN 61000-3-2; EN 61000-3-3; FCC 47 CFR Ch. 1,
Part 15
Dimensions (w × h × d)
85 × 26 × 110 mm (sender)
85 × 26 × 107 mm (receiver)
Weight
(without power supply)
approx. 300 g (sender)
approx. 200 g (receiver)
VIP 10
115
Appendix
116
Chapter 13
VIP 10
14
Index
A
Control 56
Active profile 42
Conventions 7
Actuator 19
Alarm 76
D
Alarm input 19
Data interface 18
Alarm inputs 89
Data rate 43
Alarm IP address 50
Application Wizard 29
Data terminal 21
Date format 37, 71
Audio connection 19
Daylight savings time 38, 72
Audio signals 44, 74
Defaults 44
Auto-connect 50, 77
B
Banner 63, 64
Display stamping 39
DNS server 59, 82
Dome camera 18
Dual streaming 13, 41
Brightness 41
Browser window 88
E
C
Electromagnetic compatibility 8
Echo 21
Camera ID 56, 79
Encoding interval 44
Camera name 39
EPROM 66, 84, 105
Cameras 18
Event messages 90
Changes 33
Expert Mode 28
Color depth 25, 87, 95
Color saturation 41
Communication speed 80
Configuration 67, 84
Connection 27, 89
Contrast 41
F
False alarms 51, 53
Firewall 58, 81
FTP server 46, 47
Function test 68, 86
Contrast alarm 48
VIP 10
117
Index
G
Gateway 58, 81
I
Identification 8
IGMP 61
Image resolution 93, 94
Installation 10
Installation location 17
Installation requirements 17
Chapter 14
Monitor resolution 87, 95
Motion alarm 48
MPEG-ActiveX 25, 87, 95
MPEG-sequence 94
MTU 58, 81
Multicast 60
Multicast connection 58, 60, 81
Multicast function 13
Multi-unicast 60
Installation Wizard 29
N
Interlaced video signal 44
Name 35, 69
Internal clock 38, 72
IP address 22, 58, 81
J
JPEG format 46
Navigation 32
Network 19, 57, 80
Network connection 20
Normally open contact 19
JPEG posting 46
O
JPEG posting interval 47
Operation 9
L
P
Language 37, 71
Live video images 25, 89
Live video sequence 89
Parameters 23
Password 50, 77, 89
Password protection 36, 70
Livepage 63
Peripheral device control 91
Loudspeaker 20
Picture quality 60
Low Voltage Directive 8
Power supply 9
M
Main functions 15
Mains switch 20
Maintenance 10
Profile configuration 43
Profile name 43
Profiles 42
Protocol 57, 80
Monitor 18
R
Monitor name 73
Receiver 13
118
VIP 10
Chapter 14
Regulations 7
Index
U
Relay 54, 77, 90
UDP 58, 81
Relay output 19, 54, 77, 90
Unicast 60
Remote control 14
Repair 10
Restart 23
Router 61
Unit name 35, 69
Update 66, 83
Upload file 66, 84, 105
URL 26, 88, 96
User name 36, 70, 89
S
Safety 9
V
Save picture 93
Version 62, 83
Setup 11
Video loss alarm 48
SNMP 48, 75
Video output standard 73
Specifications 114
Video quality 43
Subnet mask 81
Video resolution 44
Symbols 7
Video sensor 50
Synchronous 37, 71
Video sequence 94
System messages 90
T
TCP 58, 81
W
Watermarking 40
Wizard 28, 29
Test 68, 86
Time 38, 72
Time server 38, 72
Time Server Protocol 38, 72
Time signal 38, 72
Time zone 38, 72
Transmission disturbances 73
Transmission parameters 21
Transmission rate 56
Trigger relay 55, 79
TTL 61
VIP 10
119
Index
120
Chapter 14
VIP 10
VIP 10
121
VCS Video Communication Systems AG
Forchheimer Str. 4
90425 Nuremberg, Germany
Phone: +49 911 93456-0
Fax: +49 911 93456-66
E-mail: [email protected]
http://www.vcs.com
ID No.: 2010/0205/e/1