Download Elite Robo Slide Instruction manual
Transcript
® ACCESS SYSTEMS INC eliteaccess.com Instruction Manual ROBO SLIDE Residential Gate Operator Installation instructions and manual book for architects, general contractors and dealers Click on the desired topic in the “Bookmarks” column or “Table of Contents” to select page. Copyright © 2000 by Elite Access Systems, Inc. – www.eliteaccess.com T A B L E O F C O N T E N T S 2 3 4 5 5 6 6 7 8 9 10 11 11 12 13 14 15 16 17-18 Important Notice Safely Operating Gate Configuration and Specifications Warnings and Precautions Step 1: Getting Started Step 2: Mounting Operator Step 3: Chain Installation Step 4: Gate Movement Direction Step 5: DC Power Supply Connection Step 6: “Optional” Solar Panel Step 7: Terminal Connections Step 8: Adjusting Gate Travel Distance Step 9: Timer Step 10: 2-Way Adjustable Reversing Sensor “Optional” Input Board Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions LED Descriptions Troubleshooting How to Reset Breaker Switch How to Check Fuses Gate will not close! Gate will not open! If you hear a “BEEP” sound Robo Slide Parts List Robo Slide Parts 19 19 20 20 21 21 22 © COPYRIGHT 1992 BY ELITE ACCESS SYSTEMS, INC. All rights reserved. No part of this manual may be reproduced in any means; graphic, electronic, mechanical, or photocopied without the express written permission of the publisher of this material Release 6 5/01 PLEASE DO NOT TOUCH ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN! 1 I M P O R T A N T N O T I C E IMPORTANT! Because gate coasting distance varies with temperature, Elite DOES NOT recommend the installation of a catch post. This could cause the gate to collide with the post. Correct Installation with Catch Rollers Incorrect Installation using a Catch Post! Clo Guide Rollers (Elite Part # A UHM) Clo sin sin g g Gate in Fully Opened Position Gate Clearances 1/4" Clearance from Top of Gate Catch Rollers 5" 1/2" Clearance Between Gate and Rollers Wall Minimum Clearance of 5" Between Back of Gate and Wall or Other Objects in Gate's Path CAUTION Gate A physical stop MUST be installed on the gate prior to installation of the gate operator. This will assure that the gate does not derail while in motion. S A F E L Y O P E R A T I N G G A T E Owners Must Never Let Pedestrians Cross the Path of a Moving Gate! CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall! CAUTION CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate! C O N F I G U R A T I O N A N D S P E C I F I C A T I O N S Elite's Recommended Gate Setup Configuration Warning Signs on Both Sides of Gate Guide Rollers 3" Maximum Picket Width 2"x 2" Mesh Wire Across Entire Gate Guide Rollers Over-Travel Stops on Both Ends of Gate Rail Steel V-Groove, High Speed Ball Bearing Wheels Warning Sign Clearly Visible on Gate Operator 18 VAC Plug-In Transformer, for Each Gate Operator Reinforced Concrete to Bolt Operator on U.L. Listed Underground Conduit for Wires Robo Slide Specifications: Gate Speed – 11 inch per second Maximum Gate Length – 20 feet Maximum Gate Weight – 800 pounds Maximum Cycles – 70 cycles per day with Elite's Plug-In Transformer. – Solar power cycles per day varies, Contact Elite for more Information – Battery back-up cycles (50 cycles total) AC Power Supply – 18 VAC 2.0 Amp Plug-In Transformer (Elite Part # A POW-1) AC Power Supply Wire – 14 gauge or greater landscape lighting cable rated for direct burial and 300 watts at maximum length of 1000 ft DC Power Supply – Built-in, back-up for AC or Solar power failure only Solar Power – Optional (Elite Part # SOLAR 3) Be sure to read and follow all Elite's instructions before installing and operating any Elite product. Always disconnect the gate operator's power source before repairs are attempted. Elite Access Systems, Inc. is not responsible for improper installation or CAUTION failure to comply with local building codes. R E A D E N T I R E O W N E R S M A N U A L B E F O R E I N S TA L L AT I O N Model: Robo Slide DO NOT Use for For Single Home Applications. Apartment or Condominium Applications. PLEASE DO NOT REPAIR ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN! Warnings and Precautions CAUTION 1. Do not tighten chain too tight 2. Use proper type of wheels - only 4" steel wheels with high speed ball bearings 3. Do not use a 12V transformer - use only 18 VAC 2.0 Amp 4. Do not install as a rear-mount installation 5. Use only 14 gauge or greater landscape lighting cable rated for direct burial and 300 watts STEP 1: Getting Started This gate operator is designed for single home application, or for limited commercial applications. An example of a commercial application would be a factory facility with limited cycles per day, using a plug in transformer or solar panel. S T E P B Y S T E P I N S T A L L A T I O N STEP 2: Mounting Operator Pour concrete bed for Robo Slide. Minimum size of bed is 20" x 15" x 20"d. Suggested installation for bolts is 1/2" x 3 1/2" (for red-head fastener). CHECK CHARGING FUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR OVERLOAD REVERSE SENSOR HEAVY GATE POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE OPEN RELAY IN USA CLOSE RELAY CENTRAL CONTROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF Red Head Fastener 1/2" x 3 1/2" EXIT LOOP RADIO REC RIGHT W1 OPEN TO Power Supply Line 6" Above Ground 10" 20" 8" Concrete (Reinforced Recommended) 20" 15" STEP 3: Chain Installation Minimum space between gate and output sprocket must be 4". After you position the gate operator, bolt-down the operator to the concrete bed. Make certain that the concrete bed is solid. Correct Chain Installation Incorrect Chain Installation Gate Rear Gate Front Too High or Too Low Gate Gate 4" Minimum Correct Chain Spacing Incorrect Chain Spacing S T E P B Y S T E P I N S T A L L A T I O N STEP 4: Gate Movement Direction Plug in the limit/motor harness wires to the left socket (#1) if your gate, from the inside of the property, opens to the left and closes to the right. Plug into the right socket (#2) if the gate opens to the right and closes to the left from the inside of the property. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONT ROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF EXIT LOOP RADIO REC Socket #1 W1 OPEN TO RIGH T Socket #2 OUT Open to Socket #1 IN OUT Open to Right IN Socket #2 Left S T E P B Y S T E P I N S T A L L A T I O N STEP 5: DC Power Supply Connection Use Elite's optional 18 VAC plug-in transformer (Elite Part # A POW-1). Hook up the transformer to 115 VAC. Use two, low voltage, 14 gauge / 300watt direct burial, landscape lighting cables. Hook these wires to the two yellow wires from the control board to the plug-in transformer. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR CAUTION Do Not use solar panel and plug-in transformer at the same time. REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONT ROL FIRE DEPT STRIKE OPEN To 115 VAC UP TIMER PW SAFETY LOOP ON 60 18 VAC Plug-in Transformer EXIT LOOP 0 OFF RADIO REC W1 OPEN TO RIGH T 10 8 Maximum Wire Length should not exceed 1000 ft. 14 Gauge Wires 42 6 9 7 5 3 1 Yellow Wires #2, #4 Polarity Does Not Matter After the plug-in transformer has been connected to the power source, connect the battery cable plug to the limit/motor harness plug. You will immediately hear a beep for a few seconds. After the beep, check the “Charge OK” LED...... ......it must be “ON”. Limit/Motor Harness Beep! CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONT ROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 OFF 0 EXIT LOOP RADIO REC S T E P B Y S T E P I N S T A L L A T I O N STEP 6: Optional Solar Panel Connection If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the solar panel to the two yellow wires on the control board. Sunlight will energize the batteries through the solar panel. This solar panel will charge up to 2800 Mamp/Hr in optimum conditions & 500 Mamp/Hr in light overcast conditions. For detailed specifications consult the Solar 3 Installation sheet. CHECK CHARGINGFUSE BOARD POWER POWER CAUTION Do Not use solar panel and plug-in transformer at the same time. SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY Solar Panel CENTRAL CONT (Elite Part # SOLAR 3) No Stand ROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF EXIT LOOP RADIO REC W1 OPEN TO RIGH T 10 8 Polarity Does Not Matter 42 6 9 7 5 3 1 Yellow Wires #2, #4 Energizing Robo Slide with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery . CAUTION Elite recommends using 1 or 2 larger batteries (12 VDC, 30 Amp) (Elite Part # A 12330 or A 12330 PACK) in Robo Slide when using the optional solar panel. For More Details, contact your Local Dealer 12 VDC . p 30 Am S T E P B Y S T E P I N S T A L L A T I O N STEP 7: Terminal Connections The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). The hook-ups for the radio receiver are as follows: Strike open wires go to 8 and 9 on terminal. Power supply goes to terminal 10 (positive +) and terminal 8 (negative -). Connections for other devices are shown below. Transmitters 1 2 3 4 5 6 7 8 9 10 (Elite Part #A 3060) (Elite Part #A 3089) Fire or Any Key Switch Card Reader 12 VDC Radio Receiver Terminal 8 = Grey Wire Terminal 8 = Black Wire Terminal 9 = Grey Wire Terminal 10= Red Wire External “Exit” Loop Detector Push Button External “Safety” Loop Detector 1 2 3 4 5 6 8 9 7 HELP Phone Entry 0 Photo Electric Eye S T E P B Y S T E P I N S T A L L A T I O N STEP 8: Adjusting Gate Travel Distance Adjustment is done by limit switches which are located on the Robo Slide chassis. By pressing the plate down and spinning the adjustment nuts, set your limit switches for open and close cycles. Limit Switches Each notch of the nut indicates an estimated 1 inch of gate travel STEP 9: Timer If you want to use the automatic close for the gate system the timer switch should be put in the “ON” position. If you want to use the push open or push close command, the timer should be switched to the “OFF” position. CHECK CHARGINGFUSE BOARD POWER POWER TIMER UP ON 60 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER 0 CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY OFF CLOSE RELAY CENTRAL CONT ROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF TIMER UP PW ON 60 OFF 0 EXIT LOOP RADIO REC OPEN TO RIGH T W1 Set Timer 1 to 60 seconds SYSTEM ON J2 PW S T E P B Y S T E P I N S T A L L A T I O N STEP 10: Two-Way Adjustable Reversing Sensor There is a blue pot with a white screw adjustment on the upper portion of the control board marked “REVERSE SENSOR”. Do Not Touch Alarm Sensor blue pot. The level of sensitivity has to do with the weight of the gate and the condition of installation. Too sensitive = if the gate stops or reverses by itself. Not sensitive enough = if the gate hits an object and does not stop or reverse. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 SYSTEM ON ALARM SENSOR ALARM SENSOR Minimum Sensitivity HEAVY GATE REVERSE SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONT ROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF OPEN TO RIGH T W1 Maximum Sensitivity EXIT LOOP RADIO REC There is an LED “HEAVY GATE” which will light up when the gate is heavier than normal for the operator. The operator will still function properly. NOW YOUR INSTALLATION IS COMPLETE “ O P T I O N A L ” I N P U T B O A R D The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. Below lists the function of each pin. 1 & 2 Open Switch Use a Normally Closed Contact W1 3 & 4 Stop Switch (Cut W1 Jumper at Bottom of Board) 5 & 6 Timer Close Output from Master to Slave 7 & 8 Timer Input from Slave to Master (Close Command) 9 &10 Vandalism Alarm Output (Not Burglar Alarm) - 12 VDC 11 & 4 Emergency Open (Direct Command from Battery to Motor) 12 & 7 Emergency Close (Direct Command from Battery to Motor) 13 & 14 Magnetic Lock - Dry Contact Relay (Com NC) 15 & 16 Center Loop Option (For Swing Gate Operators Only) 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR OVERLOAD REVERSE SENSOR HEAVY GATE POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL FIRE DEPT M A S T E R A N D S L A V E W I T H T I M E R To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot. Refer to Optional Input Board Caution: 18 VAC plug-in transformer, per gate operator required Master Slave 4 Low Voltage Wires Connect Gate Operators Together 2 1 5 1 3 15 7 9 11 13 4 14 16 8 10 12 7 3 9 11 13 15 4 6 Master Pin 5 to Slave Pin 7 Master Pin 1 to Slave Pin 1 6 5 2 10 12 14 16 8 Master Pin 6 to Slave Pin 8 Master Pin 2 to Slave Pin 2 Slave J2 Plug Master J2 Plug 1. Make master/slave J2 plug connections as shown above 2. Turn timers on BOTH control boards to the “ON” position 3. Use MASTER timer ONLY for the auto close time adjustment (0 to 60 sec) 4. Turn the SLAVE timer adjustment all the way Counterclockwise Master Timer “ON” TIMER Set Timer 0 to 60 seconds UP ON 60 OFF PW Slave Timer “ON” TIMER UP PW ON 0 60 0 OFF Maximum Counterclockwise Setting M A S T E R A N D S L A V E W I T H O U T T I M E R To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot. Refer to Optional Input Board Caution: 18 VAC plug-in transformer, per gate operator required Master Slave 2 Low Voltage Wires Connect Gate Operators Together 1 1 11 13 15 3 5 7 9 3 16 10 12 14 4 6 8 5 4 6 2 Master Pin 1 to Slave Pin 1 2 7 9 11 13 15 8 10 12 14 16 Slave J2 Plug Master Pin 2 to Slave Pin 2 Master J2 Plug 1. Make master/slave J2 plug connections as shown above 2. Turn timers on BOTH control boards to the “OFF” position Master Timer “OFF” TIMER UP PW Slave Timer “OFF” TIMER UP PW ON ON 60 OFF 0 60 OFF 0 C O N T R O L B O A R D F U N C T I O N S 1 Power on LED 2 Charge on LED 3 Low battery indicator LED 4 Heavy gate indicator LED 5 Open Relay LED 6 Close Relay LED 7 System on, Reversing sensor and Alarm sensor 8 Alarm sensor LED 9 Reversing sensor LED (Rebounder) 10 Central control LED 11 Fire department or key switch LED 12 Strike open LED 13 Safety loop or photocell LED 14 Exit loop LED 15 Radio receiver LED 16 Timer power LED 17 Timer-Up indicator 18 J2 alternate optional output 19 Movement direction sockets 20 Replace fuse indicator 21 Spike suppressor 22 Jumper for stop button 23 Optional Input board 24 Plug in power - 18 VAC or solar panel and terminal block connector 25 Breaker reset 26 Overload LED 23 18 20 7 CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR 26 REVERSE SENSOR 9 HEAVY GATE OVERLOAD 4 POWER 1 2 3 8 CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CO NTROL 5 FIRE DEPT 6 STRIKE OPEN UP TIMER PW SAFETY LOOP ON 60 0 OFF 25 OPEN TO RIG EXIT LOOP RADIO REC 10 11 12 13 14 15 16 17 HT W1 21 19 22 24 L E D LED Description 1 Power at all times when there is one or more power sources ie: Battery, 18 VAC or solar 2 Charger OK on when there is any charging power ie: 18 VAC - solar 3 Battery Low normally off - it will indicate low battery 4 Heavy Gate will work only when the gate is in motion D E S C R I P T I O N LED On Power source OK and board power fuse OK LED Off 1. No power source at all If dimmed down 1. Bad board power fuse 1. No Transformer or Solar Transformer or solar OK and charging power fuse OK Flashing LED - Battery is less than required limit needs to be recharged 1. Excess usage 2. Bad charging system 3. Under rate solar panel 4. Bad battery 5. Bad battery connection 1. Gate is too heavy 2. Bad wheels 3. Bad rollers 4. Chain is too tight 5. Steep slope on open or close cycle 6. Low battery If dimmed down 1. Bad Charging power fuse Battery OK Battery voltage is over minimum required limit Gate weight and condition are OK 5 Open Relay Open relay is energized Open relay is not energized 6 Close Relay Close relay is energized Close relay is not energized Detecting motor current 1. Motor stop 2. No motor current detected 7 System On will work only when the gate is in motion 8 Alarm Sensor when LED goes on you will hear a beep sound for about 20 seconds 1. Hearing beep sound means overload 2. Gate is too heavy 3. Broken wheel 4. Gate off track 5. Unwanted object has physically stopped gate System is OK Note: Circled red numbers indicates location on control board. Refer to Control Board Functions L E D D E S C R I P T I O N LED Description 9 Reversing Sensor - C O N T I N U E D LED On LED Off Sensor is detecting obstruction No obstruction is detected Acknowledgement of receiving open command from one of the terminals 10 Central Control • Fire Department • Strike Open • Safety Loop • Exit Loop • Radio Receiver 1&2 3&4 5&6 7&8 8&9 Not receiving any command 11 Fire Dept Receiving signal at terminal block 1 & 2 Not receiving signal at terminal block 1 & 2 12 Strike Open Receiving signal at terminal block 3 & 4 Not receiving signal at terminal block 3 & 4 13 Safety Loop Receiving signal at terminal block 5 & 6 Not receiving signal at terminal block 5 & 6 14 Exit Loop Receiving signal at terminal block 7 & 8 Not receiving signal at terminal block 7 & 8 15 Radio Rec Receiving signal at terminal block 8 & 9 Not receiving signal at terminal block 8 & 9 16 Timer PW Timer power is on Timer is not on 17 Timer UP Output signal to close relay Not receiving signal to close relay Note: Circled red numbers indicates location on control board. Refer to Control Board Functions T R O U B L E S H O O T I N G How to Reset the Breaker If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker will kick-out. Reset the breaker by pressing the reset button located on the bottom left corner of the control board. Always disconnect the battery before resetting the breaker or injury could CAUTION occur as the gate starts. OPEN TO RI GHT The breaker reset is located at the bottom left corner of the control board as shown How to Check the Fuses If the gate is not moving in any direction be sure to check all of the LED displays on the control board. If the board power or charging power LEDs are “ON”, change the corresponding fuse on the top left corner of the board. CAUTION Replace fuse with 1.5A - 250V fuse CHECK FUSE CHARGING POWER BOARD POWER J2 OVERLOAD HEAVY GATE POWER CHARGE OK BATTERY LOW Robo Fuse (Elite Part # Q162) OPEN RELAY CLOSE RELAY DC OPE MAD T R O U B L E S H O O T I N G The Gate Will Not Close! DC OPERATOR v 5M MADE IN USA CENTRAL CONT ROL FIRE DEPT STRIKE OPEN PW SAFETY LOOP 0 EXIT LOOP RADIO REC Symptom: The radio receiver LED on the control board remains “ON” when using the remote control. Possible Solutions: Stuck remote control button. The radio receiver has malfunctioned in the “ON” position. The Gate Will Not Open! DC OPERATOR v 5M MADE IN USA CENTRAL CONT ROL FIRE DEPT STRIKE OPEN PW SAFETY LOOP 0 EXIT LOOP RADIO REC Symptom: The radio receiver LED on the control board remains “OFF” when using the remote control. Possible Solutions: Dead battery in the remote control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the “OFF” position. For further information, contact your local dealer. T R O U B L E S H O O T I N G a n d P A R T S L I S T If you hear a “BEEP” sound, the gate is too heavy. If not check below. ALARM SENSOR 1 Debris is on the gate's track such as mud, rocks dirt, etc. 2 The gate is hitting a wall or a car. ALARM SENSOR 3 The gate has one or more broken wheels. ALARM SENSOR ALARM SENSOR 4 A car has hit the gate and the gate is off the track. After fixing the problem, the Robo Slide will automatically reset itself. Robo Slide Parts List Robo Slide Conversion Kit Q211 - Limit/Motor Harness Q218 - Terminal Harness Q204 Q206 - Control Board Battery Harness A BT 12 - 12 VDC, 7 amp. Battery with Harness A H-110 - Gate Chain #41 (10 ft) (20 ft included) A H-111 - Gate Chain #40 (10 ft) Optional A H-113 - Master Link A H-125 - Master Link Q003 - Chain Bolt Q004 - Chain Bracket Q006 - PC Board Nuts (1 Set) Q029 - Limit Switch Q032 - Limit Switch Adjustment Nut Q101 - Limit Switch Bearing Holder Q123 - Motor - DC - 12V Q124 - Chassis Q129 - Idler Sprocket with Bolt/Nut Q131 - Limit Switch Drive Sprocket Q132 - Limit Switch Sprocket Q133 - Drive Sprocket Q135 - Limit Switch Bolt (Shaft) Q137 - Limit Switch Box Q156 - 1/2 Inch Collar Q162 - Fuse Q180 - 1 inch Diameter Coupling Q203 - Option Board with Harness Q206 - Control Board Q211 - Limit/Motor Harness Q212 - Gear Reducer 40 - 30:1 Q218 - Terminal Harness Q241 - Cover, Polyethylene Plastic Multiple Parts “Q” Number 21 R O B O S L I D E P A R T S CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Q206 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONTROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON Q211 60 0 OFF EXIT LOOP RADIO REC W1 OPEN TO RIGHT Q218 Battery Harness Q204 Conversion Kit Q203 CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD Q162 POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONTROL FIRE DEPT STRIKE OPEN Q006 UP TIMER PW SAFETY LOOP ON 60 0 OFF EXIT LOOP Q206 RADIO REC W1 OPEN TO RIGHT Q123 Q241 Q211 Q133 Q180 Q218 *Q129 Q131 Q134 A BT 12 Q156 Q212 *Q032 Q132 A H-110 #41 A H-113 A H-111 #40 A H-125 *Q003 *Q004 Q124 *Q101 *Q029 Q137 Note: *Sold Individually, 2 Shown. For part names, refer to parts list Q135