Download Elite Robo Slide Instruction manual

Transcript
®
ACCESS SYSTEMS INC
eliteaccess.com
Instruction Manual
ROBO SLIDE
Residential Gate Operator
Installation instructions and manual book for
architects, general contractors and dealers
Click on the desired topic in the “Bookmarks” column or “Table of Contents” to select page.
Copyright © 2000 by Elite Access Systems, Inc. – www.eliteaccess.com
T A B L E
O F
C O N T E N T S
2
3
4
5
5
6
6
7
8
9
10
11
11
12
13
14
15
16
17-18
Important Notice
Safely Operating Gate
Configuration and Specifications
Warnings and Precautions
Step 1: Getting Started
Step 2: Mounting Operator
Step 3: Chain Installation
Step 4: Gate Movement Direction
Step 5: DC Power Supply Connection
Step 6: “Optional” Solar Panel
Step 7: Terminal Connections
Step 8: Adjusting Gate Travel Distance
Step 9: Timer
Step 10: 2-Way Adjustable Reversing Sensor
“Optional” Input Board
Master and Slave Operators with Timer
Master and Slave Operators without Timer
Control Board Functions
LED Descriptions
Troubleshooting
How to Reset Breaker Switch
How to Check Fuses
Gate will not close!
Gate will not open!
If you hear a “BEEP” sound
Robo Slide Parts List
Robo Slide Parts
19
19
20
20
21
21
22
© COPYRIGHT 1992 BY ELITE ACCESS SYSTEMS, INC.
All rights reserved. No part of this manual may be reproduced in any means; graphic,
electronic, mechanical, or photocopied without the express written permission of the
publisher of this material
Release 6
5/01
PLEASE DO NOT TOUCH ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN!
1
I M P O R T A N T
N O T I C E
IMPORTANT! Because gate coasting distance varies with temperature, Elite DOES NOT
recommend the installation of a catch post. This could cause the gate to collide with the post.
Correct Installation with Catch Rollers
Incorrect Installation
using a Catch Post!
Clo
Guide Rollers
(Elite Part # A UHM)
Clo
sin
sin
g
g
Gate in Fully Opened Position
Gate Clearances
1/4" Clearance from Top of Gate
Catch Rollers
5"
1/2" Clearance
Between Gate
and Rollers
Wall
Minimum Clearance of 5" Between Back of Gate
and Wall or Other Objects in Gate's Path
CAUTION
Gate
A physical stop MUST be installed on the gate prior to installation of the gate
operator. This will assure that the gate does not derail while in motion.
S A F E L Y
O P E R A T I N G
G A T E
Owners Must Never Let Pedestrians Cross the Path of a Moving Gate!
CAUTION
Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall!
CAUTION
CAUTION
Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate!
C O N F I G U R A T I O N
A N D
S P E C I F I C A T I O N S
Elite's Recommended Gate Setup Configuration
Warning Signs on Both Sides of Gate
Guide Rollers
3" Maximum Picket Width
2"x 2" Mesh Wire
Across Entire Gate
Guide Rollers
Over-Travel Stops
on Both Ends of
Gate Rail
Steel V-Groove, High Speed Ball Bearing Wheels
Warning Sign Clearly Visible on Gate Operator
18 VAC Plug-In Transformer,
for Each Gate Operator
Reinforced Concrete to Bolt Operator on
U.L. Listed Underground Conduit for Wires
Robo Slide Specifications:
Gate Speed – 11 inch per second
Maximum Gate Length – 20 feet
Maximum Gate Weight – 800 pounds
Maximum Cycles – 70 cycles per day with Elite's Plug-In Transformer.
– Solar power cycles per day varies, Contact Elite for more Information
– Battery back-up cycles (50 cycles total)
AC Power Supply – 18 VAC 2.0 Amp Plug-In Transformer (Elite Part # A POW-1)
AC Power Supply Wire – 14 gauge or greater landscape lighting cable rated for direct burial and
300 watts at maximum length of 1000 ft
DC Power Supply – Built-in, back-up for AC or Solar power failure only
Solar Power – Optional (Elite Part # SOLAR 3)
Be sure to read and follow all Elite's instructions before installing and operating any
Elite product. Always disconnect the gate operator's power source before repairs are
attempted. Elite Access Systems, Inc. is not responsible for improper installation or
CAUTION failure to comply with local building codes.
R E A D E N T I R E O W N E R S M A N U A L B E F O R E I N S TA L L AT I O N
Model:
Robo Slide
DO NOT Use for
For Single Home Applications.
Apartment or Condominium Applications.
PLEASE DO NOT REPAIR ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN!
Warnings and Precautions
CAUTION
1. Do not tighten chain too tight
2. Use proper type of wheels - only 4" steel wheels with high speed ball bearings
3. Do not use a 12V transformer - use only 18 VAC 2.0 Amp
4. Do not install as a rear-mount installation
5. Use only 14 gauge or greater landscape lighting cable rated for direct burial and 300 watts
STEP 1: Getting Started
This gate operator is designed for single home application, or for limited commercial
applications. An example of a commercial application would be a factory facility with
limited cycles per day, using a plug in transformer or solar panel.
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 2: Mounting Operator
Pour concrete bed for Robo Slide. Minimum size of bed is 20" x 15" x 20"d. Suggested
installation for bolts is 1/2" x 3 1/2" (for red-head fastener).
CHECK
CHARGING FUSE
BOARD
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
OVERLOAD
REVERSE
SENSOR
HEAVY
GATE
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR
v 5M
MADE
OPEN RELAY
IN USA
CLOSE RELAY
CENTRAL CONTROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
Red Head Fastener
1/2" x 3 1/2"
EXIT
LOOP
RADIO
REC
RIGHT
W1
OPEN TO
Power Supply Line
6" Above
Ground
10"
20"
8"
Concrete
(Reinforced Recommended)
20"
15"
STEP 3: Chain Installation
Minimum space between gate and output sprocket must be 4". After you position the gate
operator, bolt-down the operator to the concrete bed. Make certain that the concrete bed is solid.
Correct Chain Installation
Incorrect Chain Installation
Gate Rear
Gate Front
Too High
or
Too Low
Gate
Gate
4" Minimum
Correct Chain Spacing
Incorrect Chain Spacing
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 4: Gate Movement Direction
Plug in the limit/motor harness wires to the left socket (#1) if your gate, from the inside of
the property, opens to the left and closes to the right. Plug into the right socket (#2) if the
gate opens to the right and closes to the left from the inside of the property.
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
EXIT
LOOP
RADIO
REC
Socket #1
W1
OPEN TO RIGH
T
Socket #2
OUT
Open to
Socket #1
IN
OUT
Open to
Right
IN
Socket #2
Left
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 5: DC Power Supply Connection
Use Elite's optional 18 VAC plug-in transformer (Elite Part # A POW-1). Hook up the
transformer to 115 VAC. Use two, low voltage, 14 gauge / 300watt direct burial, landscape
lighting cables. Hook these wires to the two yellow wires from the control board to the
plug-in transformer.
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
CAUTION
Do Not use solar panel and plug-in
transformer at the same time.
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
To
115 VAC
UP
TIMER
PW
SAFETY
LOOP
ON
60
18 VAC Plug-in Transformer
EXIT
LOOP
0
OFF
RADIO
REC
W1
OPEN TO RIGH
T
10 8
Maximum Wire Length
should not exceed 1000 ft.
14 Gauge Wires
42
6
9 7
5 3
1
Yellow Wires #2, #4
Polarity Does Not Matter
After the plug-in transformer has been connected to the power source, connect the battery
cable plug to the limit/motor harness plug. You will immediately hear a beep for a few
seconds. After the beep, check the “Charge OK” LED......
......it must be “ON”.
Limit/Motor Harness
Beep!
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
OFF
0
EXIT
LOOP
RADIO
REC
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 6: Optional Solar Panel Connection
If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the
solar panel to the two yellow wires on the control board. Sunlight will energize the batteries
through the solar panel. This solar panel will charge up to 2800 Mamp/Hr in optimum
conditions & 500 Mamp/Hr in light overcast conditions. For detailed specifications consult
the Solar 3 Installation sheet.
CHECK
CHARGINGFUSE BOARD
POWER
POWER
CAUTION
Do Not use solar panel and plug-in
transformer at the same time.
SYSTEM ON
J2
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
Solar Panel
CENTRAL CONT
(Elite Part # SOLAR 3)
No Stand
ROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
EXIT
LOOP
RADIO
REC
W1
OPEN TO RIGH
T
10 8
Polarity Does
Not Matter
42
6
9 7
5 3
1
Yellow Wires #2, #4
Energizing Robo Slide with solar power only needs the radio receiver to operate the gate.
The only recommended external devices other than radio receivers are dry-contact
command devices which do not consume any current like key switches. Using other
devices that consume high current such as telephone access, magnetic locks or loop
detectors will cause excess drainage of the battery and eventually completely drain the
battery .
CAUTION
Elite recommends using 1 or
2 larger batteries (12 VDC, 30
Amp) (Elite Part # A 12330 or
A 12330 PACK) in Robo Slide
when using the optional solar
panel.
For More Details,
contact your Local Dealer
12 VDC .
p
30 Am
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 7: Terminal Connections
The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety
or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). The hook-ups
for the radio receiver are as follows: Strike open wires go to 8 and 9 on terminal. Power
supply goes to terminal 10 (positive +) and terminal 8 (negative -). Connections for other
devices are shown below.
Transmitters
1 2 3 4 5 6 7 8 9 10
(Elite Part #A 3060)
(Elite Part #A 3089)
Fire or
Any Key
Switch
Card
Reader
12 VDC Radio Receiver
Terminal 8 = Grey Wire
Terminal 8 = Black Wire
Terminal 9 = Grey Wire
Terminal 10= Red Wire
External “Exit” Loop Detector
Push
Button
External “Safety” Loop Detector
1
2
3
4
5
6
8
9
7
HELP
Phone
Entry
0
Photo Electric Eye
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 8: Adjusting Gate Travel Distance
Adjustment is done by limit switches which are located on the Robo Slide chassis. By
pressing the plate down and spinning the adjustment nuts, set your limit switches for open
and close cycles.
Limit Switches
Each notch of the nut indicates an
estimated 1 inch of gate travel
STEP 9: Timer
If you want to use the automatic close for the gate system the timer switch should be put in
the “ON” position. If you want to use the push open or push close command, the timer
should be switched to the “OFF” position.
CHECK
CHARGINGFUSE BOARD
POWER
POWER
TIMER
UP
ON
60
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
0
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
OFF
CLOSE RELAY
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
TIMER
UP
PW
ON
60
OFF
0
EXIT
LOOP
RADIO
REC
OPEN TO RIGH
T
W1
Set Timer
1 to 60 seconds
SYSTEM ON
J2
PW
S T E P
B Y
S T E P
I N S T A L L A T I O N
STEP 10: Two-Way Adjustable Reversing Sensor
There is a blue pot with a white screw adjustment on the upper portion of the control
board marked “REVERSE SENSOR”. Do Not Touch Alarm Sensor blue pot.
The level of sensitivity has to do with the weight of the gate and the condition of
installation.
Too sensitive = if the gate stops or reverses by itself.
Not sensitive enough = if the gate hits an object and does not stop or reverse.
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
SYSTEM ON
ALARM
SENSOR
ALARM
SENSOR
Minimum
Sensitivity
HEAVY
GATE
REVERSE
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
OPEN TO RIGH
T
W1
Maximum
Sensitivity
EXIT
LOOP
RADIO
REC
There is an LED “HEAVY GATE” which will light up when the gate is heavier than normal for
the operator. The operator will still function properly.
NOW YOUR INSTALLATION IS COMPLETE
“ O P T I O N A L ”
I N P U T
B O A R D
The optional board allows extra control of the gate, is available only from Elite Access
Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the
control board. Below lists the function of each pin.
1 & 2 Open Switch
Use a
Normally
Closed
Contact
W1
3 & 4 Stop Switch (Cut W1 Jumper at Bottom of Board)
5 & 6 Timer Close Output from Master to Slave
7 & 8 Timer Input from Slave to Master (Close Command)
9 &10 Vandalism Alarm Output (Not Burglar Alarm) - 12 VDC
11 & 4 Emergency Open (Direct Command from Battery to Motor)
12 & 7 Emergency Close (Direct Command from Battery to Motor)
13 & 14 Magnetic Lock - Dry Contact Relay (Com NC)
15 & 16 Center Loop Option (For Swing Gate Operators Only)
1 3 5 7 9 11 13 15
2 4 6 8 10 12
14 16
16-Pin Plug
CHECK
CHARGINGFUSE BOAR
D
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
OVERLOAD
REVERSE
SENSOR
HEAVY
GATE
POWER
CHARGE OK
BATTERY LOW
OPEN RELAY
CLOSE RELAY
DC OPERATOR v
5M
MADE IN USA
CENTRAL CO
NTROL
FIRE
DEPT
M A S T E R
A N D
S L A V E
W I T H
T I M E R
To use the master/slave option with Robo Slide, you must purchase the Optional Input
Board (Elite Part # Q203) and connect it to the J2 slot. Refer to Optional Input Board
Caution: 18 VAC plug-in transformer, per gate operator required
Master
Slave
4 Low Voltage Wires Connect Gate Operators Together
2
1
5
1
3
15
7 9 11 13
4
14 16
8 10 12
7
3
9 11 13 15
4 6
Master Pin 5 to Slave Pin 7
Master Pin 1 to Slave Pin 1
6
5
2
10 12 14
16
8
Master Pin 6 to Slave Pin 8
Master Pin 2 to Slave Pin 2
Slave J2 Plug
Master J2 Plug
1. Make master/slave J2 plug connections as shown above
2. Turn timers on BOTH control boards to the “ON” position
3. Use MASTER timer ONLY for the auto close time adjustment (0 to 60 sec)
4. Turn the SLAVE timer adjustment all the way Counterclockwise
Master Timer “ON”
TIMER
Set Timer
0 to 60 seconds
UP
ON
60
OFF
PW
Slave Timer “ON”
TIMER
UP
PW
ON
0
60
0
OFF
Maximum
Counterclockwise
Setting
M A S T E R
A N D
S L A V E
W I T H O U T
T I M E R
To use the master/slave option with Robo Slide, you must purchase the Optional Input
Board (Elite Part # Q203) and connect it to the J2 slot. Refer to Optional Input Board
Caution: 18 VAC plug-in transformer, per gate operator required
Master
Slave
2 Low Voltage Wires Connect Gate Operators Together
1
1
11 13 15
3 5 7 9
3
16
10 12 14
4 6 8
5
4 6
2
Master Pin 1 to Slave Pin 1
2
7
9 11 13 15
8 10 12
14 16
Slave J2 Plug
Master Pin 2 to Slave Pin 2
Master J2 Plug
1. Make master/slave J2 plug connections as shown above
2. Turn timers on BOTH control boards to the “OFF” position
Master Timer “OFF”
TIMER
UP
PW
Slave Timer “OFF”
TIMER
UP
PW
ON
ON
60
OFF
0
60
OFF
0
C O N T R O L
B O A R D
F U N C T I O N S
1 Power on LED
2 Charge on LED
3 Low battery indicator LED
4 Heavy gate indicator LED
5 Open Relay LED
6 Close Relay LED
7 System on, Reversing sensor and Alarm sensor
8 Alarm sensor LED
9 Reversing sensor LED (Rebounder)
10 Central control LED
11 Fire department or key switch LED
12 Strike open LED
13 Safety loop or photocell LED
14 Exit loop LED
15 Radio receiver LED
16 Timer power LED
17 Timer-Up indicator
18 J2 alternate optional output
19 Movement direction sockets
20 Replace fuse indicator
21 Spike suppressor
22 Jumper for stop button
23 Optional Input board
24 Plug in power - 18 VAC or solar panel
and terminal block connector
25 Breaker reset
26 Overload LED
23
18
20
7
CHECK
CHARGINGFUSE
POWER
BOARD
POWER
SYSTEM ON
J2
ALARM
SENSOR
26
REVERSE
SENSOR
9
HEAVY
GATE
OVERLOAD
4
POWER
1
2
3
8
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CO
NTROL
5
FIRE
DEPT
6
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
25
OPEN TO RIG
EXIT
LOOP
RADIO
REC
10
11
12
13
14
15
16
17
HT
W1
21
19
22
24
L E D
LED Description
1 Power at all times when
there is one or more
power sources
ie: Battery, 18 VAC or solar
2 Charger OK on when there
is any charging power
ie: 18 VAC - solar
3 Battery Low
normally off - it will
indicate low battery
4 Heavy Gate
will work only when the
gate is in motion
D E S C R I P T I O N
LED On
Power source OK and
board power fuse OK
LED Off
1. No power source at all
If dimmed down
1. Bad board power fuse
1. No Transformer or Solar
Transformer or solar OK
and charging power fuse OK
Flashing LED - Battery is
less than required limit
needs to be recharged
1. Excess usage
2. Bad charging system
3. Under rate solar panel
4. Bad battery
5. Bad battery connection
1. Gate is too heavy
2. Bad wheels
3. Bad rollers
4. Chain is too tight
5. Steep slope on open or
close cycle
6. Low battery
If dimmed down
1. Bad Charging power fuse
Battery OK
Battery voltage is over
minimum required limit
Gate weight and
condition are OK
5 Open Relay
Open relay is energized
Open relay is not energized
6 Close Relay
Close relay is energized
Close relay is not energized
Detecting motor current
1. Motor stop
2. No motor current detected
7 System On
will work only when the
gate is in motion
8 Alarm Sensor
when LED goes on you
will hear a beep sound
for about 20 seconds
1. Hearing beep sound
means overload
2. Gate is too heavy
3. Broken wheel
4. Gate off track
5. Unwanted object has
physically stopped gate
System is OK
Note: Circled red numbers indicates location on control board. Refer to Control Board Functions
L E D
D E S C R I P T I O N
LED Description
9
Reversing Sensor
-
C O N T I N U E D
LED On
LED Off
Sensor is detecting obstruction
No obstruction is detected
Acknowledgement of
receiving open command
from one of the terminals
10 Central Control
• Fire Department
• Strike Open
• Safety Loop
• Exit Loop
• Radio Receiver
1&2
3&4
5&6
7&8
8&9
Not receiving any command
11 Fire Dept
Receiving signal at terminal
block 1 & 2
Not receiving signal at
terminal block 1 & 2
12 Strike Open
Receiving signal at terminal
block 3 & 4
Not receiving signal at
terminal block 3 & 4
13 Safety Loop
Receiving signal at terminal
block 5 & 6
Not receiving signal at
terminal block 5 & 6
14 Exit Loop
Receiving signal at terminal
block 7 & 8
Not receiving signal at
terminal block 7 & 8
15 Radio Rec
Receiving signal at terminal
block 8 & 9
Not receiving signal at
terminal block 8 & 9
16 Timer PW
Timer power is on
Timer is not on
17 Timer UP
Output signal to close relay
Not receiving signal to
close relay
Note: Circled red numbers indicates location on control board. Refer to Control Board Functions
T R O U B L E S H O O T I N G
How to Reset the Breaker
If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate,
or obstructed gate path, the breaker will kick-out. Reset the breaker by pressing the reset
button located on the bottom left corner of the control board.
Always disconnect the battery before
resetting the breaker or injury could
CAUTION occur as the gate starts.
OPEN TO RI
GHT
The breaker reset is located at
the bottom left corner of the
control board as shown
How to Check the Fuses
If the gate is not moving in any direction be sure to check all of the LED displays on the
control board. If the board power or charging power LEDs are “ON”, change the
corresponding fuse on the top left corner of the board.
CAUTION
Replace fuse with
1.5A - 250V fuse
CHECK
FUSE
CHARGING
POWER
BOARD
POWER
J2
OVERLOAD
HEAVY
GATE
POWER
CHARGE OK
BATTERY LOW
Robo Fuse
(Elite Part # Q162)
OPEN RELAY
CLOSE RELAY
DC OPE
MAD
T R O U B L E S H O O T I N G
The Gate Will Not Close!
DC OPERATOR v 5M
MADE IN USA
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
PW
SAFETY
LOOP
0
EXIT
LOOP
RADIO
REC
Symptom: The radio receiver LED on the control board
remains “ON” when using the remote control.
Possible Solutions: Stuck remote control button.
The radio receiver has malfunctioned in the “ON”
position.
The Gate Will Not Open!
DC OPERATOR v 5M
MADE IN USA
CENTRAL CONT
ROL
FIRE
DEPT
STRIKE
OPEN
PW
SAFETY
LOOP
0
EXIT
LOOP
RADIO
REC
Symptom: The radio receiver LED on the control board
remains “OFF” when using the remote control.
Possible Solutions:
Dead battery in the remote
control. Remote control code switches are different from
radio receiver code switches. The radio receiver has
malfunctioned in the “OFF” position.
For further information, contact your local dealer.
T R O U B L E S H O O T I N G
a n d
P A R T S
L I S T
If you hear a “BEEP” sound, the gate is too heavy. If not check below.
ALARM
SENSOR
1 Debris is on the gate's track such as
mud, rocks dirt, etc.
2 The gate is hitting a wall or a car.
ALARM
SENSOR
3 The gate has one or more broken wheels.
ALARM
SENSOR
ALARM
SENSOR
4 A car has hit the gate and
the gate is off the track.
After fixing the problem, the Robo Slide will automatically reset itself.
Robo Slide Parts List
Robo Slide Conversion Kit
Q211 - Limit/Motor Harness
Q218 - Terminal Harness
Q204
Q206 - Control Board
Battery Harness
A BT 12 - 12 VDC, 7 amp. Battery with Harness
A H-110 - Gate Chain #41 (10 ft) (20 ft included)
A H-111 - Gate Chain #40 (10 ft) Optional
A H-113 - Master Link
A H-125 - Master Link
Q003 - Chain Bolt
Q004 - Chain Bracket
Q006 - PC Board Nuts (1 Set)
Q029 - Limit Switch
Q032 - Limit Switch Adjustment Nut
Q101 - Limit Switch Bearing Holder
Q123 - Motor - DC - 12V
Q124 - Chassis
Q129 - Idler Sprocket with Bolt/Nut
Q131 - Limit Switch Drive Sprocket
Q132 - Limit Switch Sprocket
Q133 - Drive Sprocket
Q135 - Limit Switch Bolt (Shaft)
Q137 - Limit Switch Box
Q156 - 1/2 Inch Collar
Q162 - Fuse
Q180 - 1 inch Diameter Coupling
Q203 - Option Board with Harness
Q206 - Control Board
Q211 - Limit/Motor Harness
Q212 - Gear Reducer 40 - 30:1
Q218 - Terminal Harness
Q241 - Cover, Polyethylene Plastic
Multiple Parts “Q” Number
21
R O B O
S L I D E
P A R T S
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
Q206
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONTROL
FIRE
DEPT
STRIKE
OPEN
UP
TIMER
PW
SAFETY
LOOP
ON
Q211
60
0
OFF
EXIT
LOOP
RADIO
REC
W1
OPEN TO RIGHT
Q218
Battery
Harness
Q204
Conversion Kit
Q203
CHECK
CHARGINGFUSE BOARD
POWER
POWER
SYSTEM ON
J2
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
OVERLOAD
Q162
POWER
CHARGE OK
BATTERY LOW
DC OPERATOR v
5M
MADE IN USA
OPEN RELAY
CLOSE RELAY
CENTRAL CONTROL
FIRE
DEPT
STRIKE
OPEN
Q006
UP
TIMER
PW
SAFETY
LOOP
ON
60
0
OFF
EXIT
LOOP
Q206
RADIO
REC
W1
OPEN TO RIGHT
Q123
Q241
Q211
Q133
Q180
Q218
*Q129
Q131
Q134
A BT 12
Q156
Q212
*Q032
Q132
A H-110
#41
A H-113
A H-111
#40
A H-125
*Q003
*Q004
Q124
*Q101
*Q029
Q137
Note: *Sold Individually, 2 Shown.
For part names, refer to parts list
Q135