Download Daikin FTXS80KVMA User`s manual
Transcript
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. JMI-0107 Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM JQA-1452 All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved Printed in Japan 03/12/005 Y.K., P.C. Specifications, designs and other content appearing in this brochure are current as of February 2012 but subject to change without notice. PCRPR1208 RKS71H 1 2 FTXS25/35K RXS25/35K FTXS25KVM / RXS25KVM Cooling 2.64 (1.2-3.0) kW 9,000 (4,100-10,200) Btu/h Heating 3.37 (1.2-4.5) kW 11,500 (4,100-15,400) Btu/h FTXS35KVM / RXS35KVM Cooling 3.52 (1.2-3.8) kW 12,000 (4,100-13,000) Btu/h Heating 3.94 (1.2-5.0) kW 13,400 (4,100-17,100) Btu/h FTXS50/60/71K FTXS80KVM / RXS80KVM Cooling 8.21 (2.3-9.5) kW 28,000 (7,800-32,400) Btu/h Heating 9.5 (2.3-10.5) kW 32,400 (7,800-35,800) Btu/h RXS50/60K RXS71K FTXS50KVM / RXS50KVM FTXS90KVM / RXS90KVM Cooling 8.80 (2.3-10.5) kW 30,000 (7,800-35,800) Btu/h Heating 10.0 (2.3-11.2) kW 34,000 (7,800-38,200) Btu/h FTXS80/90/100K Cooling 5.28 (1.7-6.0) kW 18,000 (5,800-20,500) Btu/h Heating 5.86 (1.7-7.7) kW 20,000 (5,800-26,300) Btu/h FTXS100KVM / RXS100KVM Cooling 10.25 (3.0-11.2) kW 35,000 (10,200-38,200) Btu/h Heating 11.0 (3.0-11.7) kW 37,400 (10,200-39,900) Btu/h FTXS60KVM / RXS60KVM Cooling 5.86 (1.7-6.7) kW 20,000 (5,800-22,900) Btu/h Heating 6.96 (1.7-8.0) kW 23,600 (5,800-27,300) Btu/h RXS80/90K RXS100K FTXS71KVM / RXS71KVM Cooling 7.03 (2.3-8.5) kW 24,000 (7,800-29,000) Btu/h Heating 8.04 (2.3-10.0) kW 27,400 (7,900-34,100) Btu/h 3 4 The DC Inverter series features the Reluctance DC motor for compressor and DC motor for fan. This hi-tech energysaving package is completed by Daikin’s advanced swing compressor and PAM control. The FTXS25K achieves a high COP of 3.82 during cooling operation. This leading performance is possible thanks to the technologies above. COP (W/W) Cooling Heating 4.01 3.83 3.55 3.09 3.64 3.38 3.43 3.10 3.26 3.17 3.10 3.04 3.00 2.82 2.75 2.54 Model FTXS25K FTXS35K FTXS50K FTXS60K FTXS71K FTXS80K FTXS90K FTXS100K What is COP? An air conditioner’s COP (Coefficient of Performance) indicates how efficiently the unit uses energy. A higher COP means greater energy efficiency. It also means lower electricity consumption. Capacity (W) COP(W/W) = Power consumption (W) Energy-Saving Technological Features Swing Compressor Swing compressor Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation. Swing bush Refrigerant gas Integral piston of blade and roller The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor. Reluctance DC motor Reluctance DC Motor for Compressor Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air conditioners can vary their cooling/heating capacity by adjusting the power supply frequency of their compressors. In contrast, non-inverter air conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors. Inverter air conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly. Variable Capacity Operation Compressor Inverter Power Control Raise frequency Power source Lower frequency Non-inverter type air conditioner Energy Saving After the indoor temperature approaches the set temperature, Inverter Control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy-saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the room temperature. Comfortable Inverter air conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. These give higher comfort levels than with noninverter air conditioners. Power source High-speed rotation High capacity Low-speed rotation Low capacity 80 Conventional DC motor More than 20% 70 AC motor 60 50 0 30 60 90 120 Large load High capacity *4. Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. Fixed capacity PAM Control DC Motor for Fan Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can only operate at a fixed capacity. The DC motor allows fine rotation control, which reduces energy consumption. The motor also provides improvements in operational efficiency of up to 40%, compared to an AC motor. These improvements are particularly noticeable in the low-speed range. Comfortable Temperature Control Temp. Compressor off Reluctance DC motor 90 Small load Low capacity *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts. *3. The frequency range used by air conditioners during periods of stable operation. This is the range in which air conditioners operate for the longest periods. Compressor Constant speed rotation Efficiency of Reluctance DC motor *4 Rotational speed (rps) Not cool Efficiency of DC motor for fan *5 100 Efficiency (%) Powerful Neodymium magnets are used in the pink-coloured area. Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. It is more efficient at the low frequencies most commonly used by air conditioners,*3 improving efficiency by approximately 20%. Motor efficiency (%) Inverter Advantages Compared to Non-Inverter (comparison with a conventional AC motor) 80 DC motor Approx. 60 20% increase 40 Approx. AC motor 40% 20 increase 0 200 300 400 500 600 700 800 PAM (Pulse Amplitude Modulation) control reduces energy loss by controlling how often the converter switches on and off. 900 1000 Motor speed (rpm) Set temp. *5. Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. Compressor off Cools a room in less time Too cool Small temp. difference Time During cooling operation Non-inverter type Inverter type Starts What Is DC Inverter? Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance DC motor. This diagram is a representation for illustrative purpose only. 5 6 Intelligent Eye Indoor Unit Quiet Operation Intelligent Eye prevents energy wastage by using its infrared sensor to detect human movement in a room. When there is no movement, Intelligent Eye increases the temperature by 2 C to give energy savings. This reduces energy wastage if, for example, you forget to turn off the air conditioner. The function can be conveniently activated from the remote controller. Once Intelligent Eye is set, it continues to work to save energy. You do not need to push the SENSOR button each time you wish to use this function. This series gives you the choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoor Unit Quiet Operation. This function decreases the operation sound level by 3 dB (A) below the Low setting. This wide range of settings allows you to precisely control the fan speed according to your requirements. For example, Indoor Unit Quiet Operation provides you with a good night’s sleep. The sound level for FTXS25K is 22 dB (A). Top view 7m 110˚ Intelligent Eye The Intelligent Eye indicator lights when sensor movement is detected. Side view 7m FTXS25K Fan speeds Sound levels High (H) 37 dB (A) Low (L) 25 dB (A) Auto SL L M H 3 dB (A) Quiet (SL) 22 dB (A) During cooling operation When you are in the room, the air conditioner maintains the set temperature. If Intelligent Eye detects no human movement for 20 minutes, it automatically adjusts the set temperature by 2 C. Fan speed When you enter the room, Intelligent Eye automatically returns the temperature to the set level. Low High Each decrease in airflow volume reduces the sound level. Sound level Econo Mode button Indoor Unit Quiet Operation icon Intelligent Eye button Selects fan speed and Indoor Unit Quiet Operation Econo Mode Outdoor Unit Quiet Operation FTXS25/35K Running current and power consumption This function limits both the maximum running current and maximum power consumption. It is particularly effective if the cooling load is high, for example, at start-up or during large gatherings and periods of direct sunshine. Econo Mode is also useful for preventing circuit breakers from being overloaded during temporary peaks in the running current. The function is easily activated from the remote controller by pushing the ECONO button. Econo Mode is available for FTXS25/35K and 80/90/100K. Normal operation Maximum during normal operation Outdoor Unit Quiet Operation Maximum during Econo Mode Econo Mode From start-up until set temperature is reached Time • This diagram is a representation for illustrative purposes only. • Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature. 22 dB (A) Is So Quiet You Can Even Hear Whispers Outdoor Unit Quiet Operation is available for all models from 2.5 to 10.0 kW class. This function decreases the operation sound level by 3 or 4 dB (A) below the rated operation. It provides a low sound level of 43 dB (A) for RXS25K. Indoor unit Capacity may decrease when Outdoor Unit Quiet Operation is selected. 20 RXS25K Operations Sound levels Rated (H) 46 dB (A) 22 Rustling of leaves Quiet (L) 30 40 43 dB (A) 43 50 (dB (A)) Library Pendulum of a wall clock 3 dB (A) Normal office Based on “Examples of Sound Levels”, Ministry of the Environment, Japan, November 12, 2002 During cooling operation 7 Outdoor unit 8 Titanium Apatite Photocatalytic Air-Purifying Filter Mould-Proof Operation When cooling or dry operation is stopped, fan-only operation runs automatically for 1 hour. This airflow dries the inside of the indoor unit to reduce the generation of mould and odours. It is available with FTXS25/35K. Titanium apatite is a new photocatalytic material with advanced adsorption power. While the filter’s micron-level fibres trap dust, this photocatalyst effectively adsorbs and decomposes bacteria. The photocatalyst is activated simply by exposure to light. The filter delivers consistent performance for approximately 3 years if periodic maintenance is performed. Air filter Catches dust For FTXS25/35K Titanium Apatite Photocatalytic Air-Purifying Filter Wipe-Clean Flat Panel For FTXS50/60/71K For FTXS80/90/100K Note: The FTXS80/90/100K uses 3 air filters and 3 Titanium Apatite Photocatalytic Air-Purifying Filters. Bacteria removal test Testing method: Dropping method Testing organisation: Japan Spinners Inspecting Foundation Result certificate: No. 012553-1 and 012553-2 This filter is not a medical device. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter. Conventional Front Grille Design 1. Difficult to remove dust on the grille through wiping alone 2. Reduced capacity due to increased suction resistance Dust Effect of Titanium Apatite Photocatalyst Adsorbs Flat panel models can be cleaned instantly with a single wipe of a cloth across their smooth surface. If more thorough cleaning is required, the panel can also be easily removed from the unit. Apatite adsorbs bacteria. At the same time, the photocatalyst oxidises odour components, breaking them down. Removes Light Front grille design units collect dust on their air inlet grilles unless these grilles are cleaned regularly. Odours Bacteria Decomposed Deactivated Titanium Apatite Photocatalyst 9 10 3. High sound levels due to increased suction resistance Inverter Powerful Operation Home Leave Operation Vertical Auto-Swing (up and down) Inverter Powerful Operation boosts cooling/heating performance for a 20-minute period. This is convenient both when you first turn on your air conditioner and when you want to quickly change the temperature during operation. Horizontal Auto-Swing (left and right) 3-D Airflow Vertical Auto-Swing automatically moves the flaps up and down and Horizontal Auto-Swing automatically moves the louvers to the left and right. 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling/heating of even large spaces. Horizontal Auto-Swing and 3-D Airflow are available for FTXS50/60/71/80/ 90/100K. Power-Airflow Dual Flaps Comfort Airflow Mode Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this function, when you press the COMFORT button for cooling operation, the flap moves upward to prevent direct cold drafts. For heating operation, it also moves downward to prevent direct drafts and deliver warm air to the floor. Comfort Airflow Mode is available for FTXS80/90/100K. Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting. * Home Leave Operation can be set at any temperature from 18 to 32 C for cooling operation and 10 to 30 C for heating operation. Home Leave Operation is available for FTXS50/60/71K. During cooling operation, 23 C for the room temperature setting, and 28 C for the Home Leave setting. 23 C Wide-Angle Louvres Power-Airflow Dual Flaps and Wide-Angle Louvres work in tandem to precisely control both vertical and horizontal airflow for distribution of air. Power-Airflow Dual Flaps Cooling operation One push!! Heating operation Start Home Leave Operation simply by pushing its button on the remote controller. Anticorrosion Treatment of Outdoor Heat Exchanger Fins 28 C Cooling: the flaps flatten out during operation so that cool air slides off to reach the corner of the room. The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Heating: the flaps descend to blow warm air directly down to the floor to quickly warm the whole room. Cross section of anticorrosion-treated fin Indoor Unit On/Off Switch Hydrophilic film 23 C Night Set Mode Wide-Angle Louvers From a corner to the centre The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets. When you are out of your home, your air conditioner prevents large rises/falls in the indoor temperature by continuing to operate using Home Leave Operation settings. Indoor Unit On/Off Switch Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for your pleasant sleep. Room temperature is raised by 0.5 C after 60 minutes for cooling operation and the temperature is lowered by 2 C after 60 minutes for heating operation. The louvers can be adjusted by hand for FTXS25/35K and with the wireless remote controller for FTXS50/60/71/80/90/ 100K. +0.5 C Set temp. before Off timer begins to operate Cooling 2 C Heating Aluminium Corrosion-resistant acrylic resin Heat exchanger fin Push again!! When you return, you will be greeted by an airconditioned room. Just push the HOME LEAVE button again to return to your previous settings. Installation Flexibility A long piping length gives installation flexibility. Installation is possible even if there is no space for the outdoor unit near the indoor unit. Max. piping length Time 60 minutes Off timer turns on Off timer stops air conditioner Cooling operation: Room temperature is raised by 0.5 C after 60 minutes. Heating operation: Room temperature is lowered by 2 C after 60 minutes. Covers even a spacious room 11 FTXS25/35K FTXS50/60/71/80/ 90/100K 12 Max. height difference 20 m 15 m 30 m 20 m Function List Function Dictionary Comfortable Airflow Comfort Control Indoor Unit Cleanliness Models Functions Indoor unit operating sound levels are decreased by 3 dB (A) from the Low setting fan speed using the wireless remote controller. See page 8 See page 11 Outdoor Unit Quiet Operation Wide-Angle Louvres Outdoor unit operating sound levels are decreased by 3 or 4 dB (A) from the rated operation sound using the wireless remote controller. The smoothly curved Wide-Angle Louvres provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. See page 8 See page 11 Intelligent Eye Vertical Auto-Swing (up and down) Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2 C for energy savings. This function automatically moves the flaps up and down to distribute air across a room. See page 11 See page 7 Horizontal Auto-Swing (left and right) Automatic Operation Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool/warm air. This function automatically selects cooling or heating operation mode based on the room temperature at start-up. See page 11 3-D Airflow Programme Dry Function This function combines Vertical and Horizontal AutoSwing to circulate a cloud of cool/warm air right to the corners of even large spaces. This function automatically reduces the level of humidity. Titanium Apatite Photocatalytic Air-Purifying Filter DC Inverter This filter contains the new photocatalytic material titanium apatite. While the filter’s micron-level fibres trap dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance. Power-Airflow Dual Flaps Comfortable Airflow Indoor Unit Quiet Operation Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation. See page 9 Mould-Proof Operation Mould-Proof Operation automatically runs fan-only operation for 1 hour when cooling or dry operation is stopped. This airflow prevents the generation of mould and mould odours inside the indoor unit. See page 10 See page 10 Worry Free See page 11 24-Hour On/Off Timer This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Lifestyle Convenience Econo Mode Weekly Timer This mode limits maximum running current and power consumption. This improves operating efficiency and also prevents circuit breakers from being overloaded. The Weekly Timer allows up to four actions to be programmed for each day of the week. It is possible to schedule not only the on and off times, but also the desired temperatures during these periods. The Copy function also enables a daily programme to be repeated on another day or days as required. With correct programming, this function provides considerable energy savings. See page 7 Inverter Powerful Operation This function is convenient for boosting cooling/heating performance for a 20-minute period both when you first turn on your air conditioner or want to quickly change the room temperature. Night Set Mode See page 11 Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for your pleasant sleep. Room temperature is raised by 0.5 C after 60 minutes for cooling operation and the temperature is lowered by 2 C after 60 minutes for heating operation. Home Leave Operation Home Leave Operation continues operation to prevent a room from becoming too hot or cold, while you are sleeping or out of your home. Select any temperature from 18 to 32 C for cooling operation and 10 to 30 C for heating operation. Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance. Anticorrosion Treatment of Outdoor Heat Exchanger Fins Cleanliness See page 12 Self-Diagnosis with Digital Display The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Comfort Control Quick Warming Function Programme Dry Function Econo Mode Inverter Powerful Operation Home Leave Operation Indoor Unit On/Off Switch Titanium Apatite Photocatalytic Air-Purifying Filter Mould-Proof Operation Weekly Timer Night Set Mode During low outdoor temperatures, this function pre-heats the compressor to shorten the time required to discharge warm air. Automatic Defrosting Auto-Restart after Power Failure Self-Diagnosis with Digital Display Before starting heating operation, a sensor checks for frost in the outdoor unit and performs automatic defrosting if necessary so that only warm air is discharged. Outdoor Unit Hot-Start Function Functions After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts. Models See page 11 13 Automatic Operation 24-Hour On/Off Timer Others See page 11 See page 12 Intelligent Eye Wipe-Clean Flat Panel See page 12 Timers Timers Lifestyle Convenience The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure. 3-D Airflow Auto Fan Speed Worry Free This function prevents uncomfortable drafts from blowing directly on to the body. The flap changes the airflow direction. To prevent drafts, the flap moves upward during cooling operation and downward during heating operation. The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. Horizontal Auto-Swing (left and right) Worry Comfort Free Control Comfort Airflow Mode Auto-Restart after Power Failure Vertical Auto-Swing (up and down) Indoor Unit Quiet Operation The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning. Auto Fan Speed Wide-Angle Louvres Comfort Airflow Mode Wipe-Clean Flat Panel Comfort Control Power-Airflow Dual Flaps FTXS FTXS FTXS 25/35K 50/60/71K 80/90/100K 14 Outdoor Unit Quiet Operation Anticorrosion Treatment of Outdoor Heat Exchanger Fins RXS RXS RXS 25/35K 50/60/71K 80/90/100K Easy-to-Use Wireless Remote Controller Wireless remote controller for FTXS25/35K Wireless remote controller for FTXS80/90/100K Econo Mode Selects fan speed and Indoor Unit Quiet Operation On/Off Switch Sets room temperature Selects mode: cooling, heating, dry, fan-only operation Inverter Powerful Operation Vertical Auto-Swing (up and down) Outdoor Unit Quiet Operation Mould-Proof Operation Intelligent Eye On/Off Switch Selects fan speed and Indoor Unit Quiet Operation Inverter Powerful Operation Selects mode: cooling, heating, dry, fan-only operation Sets room temperature Econo Mode Vertical Auto-Swing (up and down) Outdoor Unit Quiet Operation Horizontal Auto-Swing (left and right) Intelligent Eye Comfort Airflow Mode Cancels On/Off Timer 24-Hour On Timer Sets clock 24-Hour Off Timer and Night Set Mode Sets timer Weekly Timer 24-Hour Off Timer and Night Set Mode 24-Hour On Timer Sets clock Sets timer Cancels On/Off Timer Wireless remote controller for FTXS50/60/71K Home Leave Operation On/Off Switch Selects fan speed and Indoor Unit Quiet Operation Sets room temperature Selects mode: cooling, heating, dry, fan-only operation Outdoor Unit Quiet Operation Inverter Powerful Operation Vertical Auto-Swing (up and down) Horizontal Auto-Swing (left and right) Intelligent Eye Cancels On/Off Timer 24-Hour On Timer Sets clock 24-Hour Off Timer and Night Set Mode Sets timer 15 16 Measurement conditions 1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m. 3. Sound levels are based on the temperature conditions 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. Specifications FTXS25/35/50/60K Model name Capacity Power supply Running current (220-230 V, 60 Hz) Power consumption COP Indoor unit Outdoor unit Rated Cooling (Min.-Max.) Rated Heating (Min.-Max.) kW Btu/h kW Btu/h Cooling Rated A Heating Rated Cooling W Heating (Min.-Max.) Cooling Rated W/W Heating SEER Indoor unit Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Outdoor unit Casing colour Cooling Heating m3/min (cfm) Cooling Heating dB (A) mm kg Type Motor output Refrigerant charge (R-410A) Cooling Sound levels (H/L) Heating Dimensions (H x W x D) Machine weight Cooling Operation range Heating Liquid Gas Piping connections Drain Max. piping length Max. height difference Compressor W kg dB (A) mm kg CDB CWB mm m FTXS25KVM RXS25KVM 2.64 (1.2-3.0) 9,000 (4,100-10,200) 3.37 (1.2-4.5) 11,500 (4,100-15,400) FTXS35KVM FTXS50KVM FTXS60KVM RXS35KVM RXS50KVM RXS60KVM 3.52 (1.2-3.8) 5.28 (1.7-6.0) 5.86 (1.7-6.7) 12,000 (4,100-13,000) 18,000 (5,800-20,500) 20,000 (5,800-22,900) 3.94 (1.2-5.0) 5.86 (1.7-7.7) 6.96 (1.7-8.0) 13,400 (4,100-17,100) 20,000 (5,800-26,300) 23,600 (5,800-27,300) 1 phase, 220-240 V / 220-230 V, 50/60 Hz 4.0-3.9 5.5-5.3 7.3-7.0 8.8-8.4 4.4-4.2 5.2-5.0 7.4-7.1 9.4-9.0 690 (300-800) 1,140 (300-1,200) 1,560 (440-2,080) 1,890 (440-2,390) 840 (290-1,340) 1,110 (290-1,550) 1,610 (400-2,530) 2,030 (400-2,810) 3.83 3.09 3.38 3.10 4.01 3.55 3.64 3.43 20.0 19.5 20.0 19.5 FTXS25KVM FTXS35KVM FTXS50KVM FTXS60KVM White 8.7 (307) 8.9 (314) 14.7 (519) 16.2 (572) 9.4 (332) 9.7 (342) 16.2 (572) 17.4 (614) 5 steps, quiet and automatic 37/25/22 38/26/23 44/35/32 45/36/33 37/28/25 38/29/26 42/33/30 44/35/32 230 x 1,050 x 238 283 x 800 x 195 12 9 RXS25KVM RXS35KVM RXS50KVM RXS60KVM Ivory white Hermetically sealed swing type 600 1,100 1.00 1.78 46/43 47/44 47/44 49/46 47/44 48/45 48/45 49/46 550 x 765 x 285 735 x 825 x 300 34 48 10 to 46 –15 to 18 6.4 9.4 12.7 16 20 30 15 20 Options Indoor unit No. 1 2 3 4 Item 5-room centralized controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying filter Remote controller loss prevention with chain *2 *3 FTXS80/90/100K FTXS50/60/71K KRC72 FTXS25/35K *1 KRP413AB1S KAF971B42 KAF970A46 KAF970A48 KKF910A4 KKF917A4 Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. The time clock and other devices should be obtained locally. *3. The filter is a standard accessory. It should be replaced approximately every 3 years. Titanium apatite photocatalytic air-purifying filter KAF970A46 5-room centralised controller KRC72 Titanium apatite photocatalytic air-purifying filter KAF970A48 Remote controller loss prevention with chain KKF917A4 Remote controller loss prevention with chain KKF910A4 FTXS71/80/90/100K Model name Capacity Power supply Running current (220-230 V, 60 Hz) Power consumption COP Indoor unit Outdoor unit Rated Cooling (Min.-Max.) Rated Heating (Min.-Max.) kW Btu/h kW Btu/h Cooling Rated A Heating Rated Cooling W Heating (Min.-Max.) Cooling Rated W/W Heating SEER Indoor unit Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Outdoor unit Casing colour Cooling Heating Cooling Heating Type Motor output Refrigerant charge (R-410A) Cooling Sound levels (H/L) Heating Dimensions (H x W x D) Machine weight Cooling Operation range Heating Liquid Gas Piping connections Drain Max. piping length Max. height difference Compressor m3/min (cfm) dB (A) mm kg FTXS71KVM RXS71KVM 7.03 (2.3-8.5) 24,000 (7,800-29,000) 8.04 (2.3-10.0) 27,400 (7,900-34,100) 10.2-9.8 11.4-10.3 2,220 (570-3,200) 2,470 (520-3,790) 3.17 3.26 18.1 FTXS71KVM 17.4 (614) 21.5 (759) 46/37/34 46/37/34 230 x 1,050 x 238 12 RXS71KVM W kg dB (A) 52/49 52/49 mm kg CDB CWB 6.4 mm m 17 FTXS80KVM FTXS90KVM RXS80KVM RXS90KVM 8.21 (2.3-9.5) 8.80 (2.3-10.5) 28,000 (7,800-32,400) 30,000 (7,800-35,800) 9.5 (2.3-10.5) 10.0 (2.3-11.2) 32,400 (7,800-35,800) 34,000 (7,800-38,200) 1 phase, 220-240 V / 220-230 V, 50/60 Hz 12.5-11.9 14.3-13.7 14.0-13.4 15.2-14.6 2,700 (570-3,800) 3,120 (570-4,320) 3,060 (520-3,870) 3,330 (520-4,340) 3.04 2.82 3.10 3.00 19.9 18.6 FTXS80KVM FTXS90KVM White 23.8 (840) 23.8 (840) 24.1 (852) 24.1 (852) 5 steps, quiet and automatic 49/40/37 49/40/37 49/38/35 49/38/35 340 x 1,200 x 240 17 RXS80KVM RXS90KVM Ivory white Hermetically sealed swing type 1,920 2.30 54/51 54/51 54/51 54/51 770 x 900 x 320 71 10 to 46 –15 to 18 9.5 15.9 16 30 20 FTXS100KVM RXS100KVM 10.25 (3.0-11.2) 35,000 (10,200-38,200) 11.0 (3.0-11.7) 37,400 (10,200-39,900) Outdoor unit No. 1 2 49/40/37 49/38/35 RXS100KVM 2,030 2.80 54/51 55/51 990 x 940 x 320 80 RXS25/35K KPW937A4 RXS50/60K KKP937A4 RXS71/80/90K RXS100K KPW945A4 KPW5E112 *1 KKP945A4 Note: *1. One set includes 5 pieces for 5 units. 18.5-17.7 18.3-17.5 4,040 (620-4,520) 4,000 (620-4,570) 2.54 2.75 18.8 FTXS100KVM 23.8 (840) 24.1 (852) Item Air direction adjustment grille Drain plug Air direction adjustment grille KPW945A4 Drain plug KKP937A4 Drain plug KKP945A4 Control system No. 1 2 3 4 Item Central remote controller Unified On/Off controller Schedule timer Interface adaptor for DIII-NET use FTXS25/35/50/60/71/80/90/100K DCS302CA61 DCS301BA61 DST301BA61 KRP928BB2S *1 *1 *1 Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. Central remote controller DCS302CA61 Unified On/Off controller DCS301BA61 Schedule timer DST301BA61 Specifications are subject to change. 18