PCSVN1412
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Đại lyù phaân phoái:
AIR CONDITIONING SYSTEM
COOLING ONLY [50Hz]
HEAT PUMP [50Hz]
TRUNG TÂM
DICH VU KHÁCH HÀNG
Miễn phí cöôùc cuoäc goïi
Specifications, designs and other content appearing in this brochure are current as of May 2014 but subject to change without notice.
c All rights reserved 05/14 SS
Daikin meets your needs with this full lineup of inverters for various types
of indoor units and power supplies.
CEILING MOUNTED CASSETTE TYPE
Round Flow
COMPACT MULTI FLOW CEILING
NG
MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
1
CEILING MOUNTED
SLIM DUCT TYPE
CEILING MOUNTED
BUILT-IN TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC
PRESSURE TYPE
FLOOR STANDING TYPE
2
Product Lineup
Series
25
Cooling only
35
50
60
71
100
125
140
FCQ71LUV1
RZR71LVVM
FCQ100LUV1
FCQ125LUV1
FCQ140LUV1
CEILING MOUNTED
CASSETTE TYPE
Page 9
Round Flow
FCQ50LUV1V
RZR50LUV1V
NEW
Indoor unit
Outdoor unit
FCQ60LUV1V
RZR60LUV1V
NEW
RZR100LVVM
RZR100LUY1
RZR125LVVM
RZR125LUY1
RZR140LVVM
RZR140LUY1
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit
Page 13
FFQ25BV1B
RKS25AVMG
FFQ35BV1B
RKS35AVMG
FFQ50BV1B
RKS50AVMG
FFQ60BV1B
RKS60AVMG
FHQ35BVV1B
RKS35AVMG
FHQ50BVV1V
RZR50LUV1V
FHQ60BVV1V
RZR60LUV1V
Pair
CEILING SUSPENDED TYPE
Page 15
Indoor unit
Outdoor unit
NEW
NEW
FHQ71BVV1B
RZR71LVVM
FHQ100BVV1B
RZR100LVVM
RZR100LUY1
FHQ125BVV1B
RZR125LVVM
RZR125LUY1
NEW
FHQ140CAVEB
RZR140LVVM
DUCT CONNECTION
MIDDLE and HIGH STATIC
PRESSURE TYPE
Page 19
FBQ50DV1V
RZR50LUV1V
NEW
Indoor unit
Outdoor unit
FBQ60DV1V
RZR60LUV1V
NEW
FBQ71DV1
RZR71LVVM
FBQ100DV1
RZR100LVVM
RZR100LUY1
FBQ125DV1
RZR125LVVM
RZR125LUY1
FBQ140DV1
RZR140LVVM
RZR140LUY1
FLOOR STANDING TYPE
Page 21
FVQ50CVE
RZR50LVVM
NEW
Indoor unit
Outdoor unit
FVQ60CVE
RZR60LVVM
NEW
FVQ71CVEB
RZR71LVVM
FVQ100CVEB
RZR100LVVM
RZR100LUY1
FVQ125CVEB
RZR125LVVM
RZR125LUY1
FVQ140CVEB
RZR140LVVM
RZR140LUY1
CEILING MOUNTED
CASSETTE TYPE
Page 9
Round Flow
Indoor unit
RZR125LVVM
Outdoor unit
Simultaneous Twin Multi
FCQ60LUV1X2
NEW
RZR125LUY1
NEW
FCQ71LUV1X2
RZR140LVVM
RZR140LUY1
CEILING SUSPENDED TYPE
Page 15
NEW
Indoor unit
FHQ60BVV1GX2
RZR125LVVM
Outdoor unit
RZR125LUY1
NEW
FHQ71BVV1BX2
RZR140LVVM
RZR140LUY1
DUCT CONNECTION
MIDDLE and HIGH STATIC
PRESSURE TYPE
Page 19
NEW
Indoor unit
FBQ60DV1X2
RZR125LVVM
Outdoor unit
RZR125LUY1
NEW
FBQ71DV1X2
RZR140LVVM
RZR140LUY1
FLOOR STANDING TYPE
Page 21
NEW
Indoor unit
FVQ60CVEX2
RZR125LVVM
Outdoor unit
RZR125LUY1
NEW
FVQ71CVEBX2
RZR140LVVM
RZR140LUY1
OUTDOOR UNIT
Page 23
Outdoor unit
NEW
RZR50LUV1V/LVVM
NEW
RZR60LUV1V/LVVM
NEW
RZR71LVVM
NEW
RZR100LVVM
RZR100LUY1
NEW
RZR125LVVM
RZR125LUY1
NEW
RZR140LVVM
RZR140LUY1
OUTDOOR UNIT
Outdoor unit
3
RKS25AVMG
RKS35AVMG
RKS50AVMG
RKS60AVMG
4
Product Lineup
Heat pump
25
Series
35
50
60
71
100
125
140
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Page 9
FCQ50LUV1V
RZQ50KBV1V
Indoor unit
NEW
Outdoor unit
FCQ60LUV1V
RZQ60KBV1V
NEW
FCQ71LUV1
RZQ71KCV4A
FCQ100LUV1
RZQ100KCV4A
RZQ100HAY4A
FCQ125LUV1
RZQ125KCV4A
RZQ125HAY4A
FCQ140LUV1
RZQ140KCV4A
RZQ140HAY4A
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit
Page 13
FFQ25BV1B
RXS25EBVMA
NEW
FFQ35BV1B
RXS35EBVMA
NEW
FFQ50BV1B
RXS50FVMA
NEW
FFQ60BV1B
RXS60FVMA
NEW
CEILING SUSPENDED TYPE
Page 15
FHQ35BVV1B
RXS35EBVMA
Indoor unit
NEW
Outdoor unit
FHQ50BVV1V
RZQ50KBV1V
NEW
FHQ60BVV1V
RZQ60KBV1V
NEW
FHQ71BVV1B
RZQ71KCV4A
FHQ100BVV1B
RZQ100KCV4A
RZQ100HAY4A
FHQ125BVV1B
RZQ125KCV4A
RZQ125HAY4A
NEW
FHQ140CAVEA
RZQ140KCV4A
RZQ140HAY4A
Pair
CEILING MOUNTED
SLIM DUCT TYPE
Page 17
Indoor unit
Outdoor unit
FDXS25CVMA
RXS25EBVMA
NEW
FDXS35CVMA
RXS35EBVMA
NEW
FDXS50CVMA
RXS50FAVMA
NEW
FDXS60CVMA
RXS60FVMA
NEW
CEILING MOUNTED
BUILT-IN TYPE
Page 18
FBQ50BV1A
RXS50FAVMA
Indoor unit
Outdoor unit
FBQ60BV1A
RXS60FVMA
FBQ71BV1A
RXS71FVMA
DUCT CONNECTION
MIDDLE and HIGH STATIC
PRESSURE TYPE
Page 19
FBQ50DV1V
RZQ50KBV1V
Indoor unit
NEW
Outdoor unit
FBQ60DV1V
RZQ60KBV1V
NEW
FBQ71DV1
RZQ71KCV4A
FBQ100DV1
RZQ100KCV4A
RZQ100HAY4A
FBQ125DV1
RZQ125KCV4A
RZQ125HAY4A
FBQ140DV1
RZQ140KCV4A
RZQ140HAY4A
FLOOR STANDING TYPE
Page 21
FVQ50CVE
RZQ50KBV4A
NEW
Indoor unit
Outdoor unit
FVQ60CVE
RZQ60KBV4A
NEW
FVQ71CVEB
RZQ71KCV4A
FVQ100CVEB
RZQ100KCV4A
RZQ100HAY4A
FVQ125CVEB
RZQ125KCV4A
RZQ125HAY4A
FVQ140CVEB
RZQ140KCV4A
RZQ140HAY4A
OUTDOOR UNIT
Page 23
Outdoor unit
NEW
RZQ50KBV1V/KBV4A
NEW
RZQ60KBV1V/KBV4A
RZQ71KCV4A
RXS60FVMA
RXS71FVMA
RZQ100KCV4A
RZQ100HAY4A
RZQ125KCV4A
RZQ125HAY4A
RZQ140KCV4A
RZQ140HAY4A
OUTDOOR UNIT
Outdoor unit
5
RXS25EBVMA
RXS35EBVMA
RXS50FVMA/FAVMA
6
Energy saving
Wider lineup of inverters
Achieved higher COP
Daikin meets your needs with this full lineup of inverters
for various types of indoor units and power supplies.
COP
3.70
3.57
3.60
Total of 104 combinations!
3.40
25
COMPACT MULTI FLOW CEILING
MOUNTED CASSETTE TYPE
FCQ50LUV1V FCQ60LUV1V
RZR50LUV1V RZR60LUV1V
What is COP
(Coefficient of Performance)
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Note :
*Rated cooling capacities are based on
the following conditions: Indoor temp.,
27°CDB, 19.0°CWB; outdoor temp.
35°CDB, 24.0°CWB. Equiv.
refrigeration piping, 7.5 m (horizontal).
: Cooling only
35
50
60
71
100
: Heat pump
125
140
1 Phase
CEILING MOUNTED
CASSETTE TYPE
Round Flow
1 Phase
CEILING SUSPENDED TYPE
1 Phase
3 Phase
3 Phase
Pair
Cooling*
Cooling*
Cooling*
2
Cooling*
2.85
Cooling*
3
3.84
Cooling*
4
FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1
RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM
COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy
efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance.
CEILING MOUNTED
SLIM DUCT TYPE
1 Phase
CEILING MOUNTED BUILT-IN TYPE
1 Phase
DUCT CONNECTION MIDDLE
and HIGH STATIC PRESSURE
TYPE
1 Phase
FLOOR STANDING TYPE
1 Phase
3 Phase
3 Phase
CEILING MOUNTED CASSETTE TYPE
Round Flow
New types of indoor units
3 Phase
CEILING SUSPENDED TYPE
NEW
Twin
NEW
1 Phase
1 Phase
3 Phase
DUCT CONNECTION MIDDLE and
HIGH STATIC PRESSURE
TYPE
1 Phase
FLOOR STANDING TYPE
1 Phase
3 Phase
3 Phase
Ceiling mounted slim duct type
2.5-6.0 kW class
Comfortable
Comfortable currents of air
are sent to every corner of
the room.
Refrigerant branch
piping kit for Twin Multi
operation
7
Page 28
For example, four indoor units
are judiciously spaced in this wide
single-floor restaurant to deliver comfortable
currents of air to every corner of the room.
Enhanced comfort with Inverter
Inverter performs variable control of frequency,
which determines air conditioner’s power
performance.
At startup, full power is used to achieve the set temperature quickly.
Then, the capacity is adjusted according to the outdoor temperature
changes and subtle indoor load changes to achieve fine capacity
control resulting in a more stable room temperature.
Non-inverter type
air conditioners
must be switched
on and off
repeatedly,
causing large
fluctuations of
the room
temperature.
2 sets of Twin Multi
Cooling operation
At startup, inverter
raises frequency
smoothly, eliminating
the starting current
spike.
Non-inverter
Current
Simultaneous twin multi operation
Running
current
Temp
Inverter
Starting
current
Time
Current
Ceiling suspended type
14.0 kW class
Set temp
Cools a room
in less time
Small temp.
difference
Time
Inverter power control
Non-inverter type air conditioner
Running
current
Time
8
CEILING MOUNTED CASSETTE TYPE
Round Flow
Avoids uneven temperature and discomfort caused by drafts.
Cassette air conditioner with 360°
uniform airflow sets the standard
Comfort enhanced by Round Flow!
Cooling only / Heat pump
FCQ50/60LUV1V
FCQ60/71/100/125/140LUV1
360° airflow
Air movement is gentle with Round Flow
With uniform temperature
distribution
Enhanced Comfort
360° airflow can
maintain comfort
even if air
discharge speed is
lower.
Airflow
distribution
Creates uniform
comfort throughout
the space
If you raise the set
temperature by 1 to
1.5°C,and velocity is
decreased by 25%,
you still obtain the same
feeling temperature and
comfort.
Greater comfort
Improved energy saving
Option
Accessory required for indoor unit.
Wired LCD remote controller
Adapts easily to the installation space.
BRC1C61
Note: Remote controller cable not
included. Cables must be
procured locally.
Because air flows out from corner outlets, comfort spreads more widely.
Typical flow patterns
There are a total of 23 flow patterns.
Navigation Remote Controller
(Wired Remote Controller)
All-round flow
3-way flow
(E.g., installed in
middle of ceiling)
(E.g., installed
near a wall)
L-shaped
2-way flow
Opposite
2-way flow
BRC1E62
Note: Remote controller cable not
included. Cables must be
procured locally.
Wireless LCD remote controller
Heat pump
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.
BRC7F633F
BRC7F632F
Grime prevention and bactericidal coating: Make cleaning easier.
Signal receiver unit
(Installed type)
External panels are treated with a coating that
Treated
Untreated
repels dirt.
surface
surface
Wireless remote controller and signal
receiver unit are sold as a set.
Features
*1Applicable when wired remote controller is used
*2For the outdoor units
*3Applicable when BRC1E62 is used
*4Applicable when BRC1C61 is used
9
• • •
• • •
*2
• • •
• • •
*2
Fresh air intake kit
• • • • • • • • • • • •
• • • • • • • • • • • • •
---
Others
Anti corrosion treated
heat exchangers
*4
High-efficiency filter
*3
Ultra long-life filter
*3
Interlock control
*3
Options
DIII-NET communication
standard
*3
Central remote control
*2
Auto-restart
• •
*2
Auto-cooling/heating
change-over
Control by 2 remote
controllers
Group control by 1 remote
controller
External command
control
*1
*2
Control features
Self-diagnosis function
*4
Emergency operation
*3
Low gas pressure
detection
*3
Ceiling soiling prevention
*3
Filter sign
On/Off timer
*3
Long-life filter
Off timer (programmed)
*2
Pre charged for
up to 30 m
Weekly schedule timer
---
Drain pump mechanism
Setpoint range set
---
Silver ion anti-bacterial
drain pan
Night quiet operation
Setpoint auto reset
*1
Work & Servicing
Cleanliness
Anti-bacterial air filter
Year-round cooling
applicable
High ceiling application
Programme "Dry"
Draft prevention function
(heating)
Switchable fan speed
(2 step)
• • • • •
• • • • • •
Hot start (after defrost)
Heat pump
---
Remote controller
Two selectable
temperature-sensors
Cooling only
Swing pattern selection
Auto swing
Comfort
(E.g., installed in
a long room)
4-way flow also possible.
A signal receiver must be added to the indoor unit.
Cooling only
(E.g., installed in
a corner)
*2
*2
To prevent dirt sticking to the
external panels, they have
been coated with a surface
treatment.
Resists
soiling
Grimy
surface
• Condition after exposure
to the smoke of 600
cigarettes in 1 m3
enclosed space.
Silver ion anti-bacterial
drain pan
Non-flocking flaps
Filter has anti-mould and
bactericidal treatment
Mould-proof drain pan includes a silver ion
antibacterial agent that assists in
preventing the growth of slime, bacteria,
and mould that cause smells and clogging.
Condensation does not easily form on
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
Prevents mould and microorganisms
growing out of the dust and moisture
that adheres to the filters.
10
CEILING MOUNTED CASSETTE TYPE
Fine square panels
Compact body and quiet operation
mm
95
0m
Same for
all models
m
Indoor unit
High
Low
50LUV1V
60LUV1V/V1
71LUV1
100LUV1
125LUV1
140LUV1
35
35
35
43
44
44
28
28
28
32
34
36
Optimal comfort and convenience
assured by air discharge modes
Note: Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.
Air direction
Standard setting
Setting to prevent soiling of ceiling*
Desired
situation
Standard position to
prevent draft.
Recommended for shops with
light coloured ceilings that
must be kept spotless.
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During
operation these values are
somewhat higher owing to
ambient conditions.
Quick and easy to install
5-levels
air direction
setting
Auto-swing between
15° and 60°
Auto-swing between
25° and 60°
Settable to 5 different
levels between 25° and 60°
Settable to 5 different
levels between 15° and 60°
The air direction is set automatically to the
memorised position of the previous air direction.
Auto air
direction control
*Closing of the corner discharge outlets is recommended.
Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to
the floor level.
Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
Standard
Ceiling
High ceiling
height
High ceiling
50/60LUV1V, 60/71LUV1
100–140LUV1
All round 4-way 3-way 2-way
flow
flow
flow
flow
All round 4-way 3-way 2-way
flow
flow
flow
flow
2.7 m 3.1 m 3.0 m 3.5 m
3.0 m 3.4 m 3.3 m 3.8 m
3.5 m 4.0 m 3.5 m -
3.2 m 3.4 m 3.6 m 4.2 m
3.6 m 3.9 m 4.0 m 4.2 m
4.2 m 4.5 m 4.2 m -
The condition of the drain pan and
drain water can be checked by
removing the drain plug and
intake grille.
256 mm *1
266 mm *2
Easy height adjustment
Each corner of the unit has an Adjuster Pocket that
lets you easily adjust the unit's suspended height.
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
All models can be installed without
using lifter because of the light weight.
Installable in
any direction
Since the orientation of
the intake grill can be
adjusted after installing,
the direction of the intake
grill lines can be unified
when multiple units
are installed.
Drain pump is equipped as standard
accessory with 850 mm lift.
Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve
comfort level, closer to the target area at the wired remote control. This
feature must be set during commissioning by the technicians.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Switchable fan speed: High/Low
High setting provides maximum reach while low
setting minimises drafts.
On/Off timer
Operation starts when the preset time of the ON timer elapses and stops
when the preset time of the OFF timer elapses.
11
Drain plug
Options required for specific operating environments
Ultra long-life filter
Panel spacer
Even in smoky environments where
the air conditioning is on most of
the time, the ultra long-life filter only
has to be changed once a year.
Use when only minimal space is available between drop
ceilings and ceiling slabs.
Smoky atmosphere: annual filter change
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.)
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
40mm
Ordinary store or office: filter change every 4 years
Panel spacer
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years
Note: Some ceiling constructions may hinder installation.
Contact your Daikin Dealer before installing your unit.
High-efficiency filter
Available in two types: 65% and 90% colorimetry.
Sealing material of air discharge outlet
Fresh air intake kit
Using this kit, a
duct can be fitted
to increase the
intake of outdoor
air.
Outside
A round duct can be attached without the need for a chamber.
Chamber type
(without T-joint pipe and fan)
850 mm
175 mm
Because the drain socket is
transparent, after the drain piping
has been installed, it is easy to
check if the drain come out
through the socket.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be fitted
(square slit hole).
The units can be installed in the following different ways.
Chamber type
(with T-joint pipe and without fan)
KDDP55B160
Transparent drain socket
Sealing material block air discharge openings not used in
2-way or 3-way blow.
Branch duct (direct-connection round duct)
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other
parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced
through the kit is limited to 10% of the maximum airflow rate of the
indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sending.
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Two selectable temperature-sensors
e
en th !
p
o
t
e
Jus ke grill
inta
With Ultra long-life filters (option), maintenance is not required in normal shops or offices
for up to four years.
Just 256 mm high. Installable in tight
ceiling spaces (50/60LUV1V, 60/71LUV1)
*1 298 mm high with 100–140LUV1
*2 308 mm high with 100–140LUV1
Auto-swing
Easier to maintain
dB(A)
Panel size is same for all models,
FCQ50/60LUV1V, 60-140LUV1.
It is easy to maintain a neat appearance when multiple
units are installed.
950
Round Flow
KDDP55B160K
Flexible duct
(procured locally)
Flexible duct
T-joint pipe
(procured locally)
T-joint pipe
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Direct installation type
KDDP55X160
Duct flange
(with insulation
material)
Intake duct
(procured locally)
Note: Use of options will increase operating sound.
Connection to a centralised control
system is available without option
Low gas pressure detection
12
CEILING MOUNTED
CASSETTE TYPE
COMPACT MULTI FLOW
Quiet decor-blending form and easy
installation in new or old buildings
Compact
Comfortable
Sized to fit inside 600mm wide
ceiling grids
Designed for low draft
performance
0°
575 mm
Cooling only / Heat pump
286
Less draft
can be felt
tion
Decolrais also
e
n
pa
ct.
compa
mm
Consistent comfort throughout
Auto-swing operation
distributes conditioned air
more evenly.
700 mm
Fits without the
need to cut T-bar
grid
Ceiling panel
Standard
setting
T bar
600 mm
(Set on site)
The switch box is built in to the
unit, so maintenance is possible
by simply removing the grill. An
inspection opening is not
required even for modules other
than 600 x 600.
Setting to
prevent
soiling of
ceiling
(Set on site)
BRC1E62
Quiet, small-diameter fan
3-way flow
Quiet operation has been achieved even with a
compact body and developed spiral hub cover that
reduces the static pressure inside the indoor unit.
4 patterns
Spiral hub cover
Features
*1Applicable when wired remote controller is used
*2Applicable when outdoor temperature is from 10 to 46°CDB
*3Applicable when BRC1E62 is used
13
• • •
• • •
*4Applicable when BRC1C61 is used
*5For the outdoor units
*5
*5
Option Others
Anti corrosion treated
heat exchangers
Fresh air intake kit
Interlock control
Central remote control
• • • • •
• • • • • •
• • • • • • • • • • • •
---
Indoor unit
High
Low
25B
29.5
32
36
41
24.5
25
27
32
35B
50B
External command
control
Group control by 1 remote
controller
Control by 2 remote
controllers
Auto-cooling/heating
change-over
•
*4
Auto-restart
*4
*3
Control features
Self-diagnosis function
*3
*3
Ceiling soiling prevention
On/Off timer
*3
*3
Filter sign
Off timer (programmed)
*3
*3
Long-life filter
Weekly schedule timer
*3
*2
Pre charged for
up to 10 m
Setpoint range set
*2
Drain pump mechanism
Setpoint auto reset
---
*1
Mould-proof drain pan
Year-round cooling
applicable
*1
Anti-bacterial air filter
Hot start (after defrost)
---
Two selectable
temperature-sensors
Programme "Dry"
Switchable fan speed
(2 step)
Draft prevention function
(heating)
Swing pattern selection
Auto swing
• •
• •
• • • • •
Settable to 5 different levels
between 25° and 60°
Air direction can be
selected according to
installation.
Note: Operation sound increases
when using 2-way or 3-way flow.
Two selectable temperature-sensors
dB(A)
Heat pump
60°
Note: For 3-way or 2-way flow installation, the sealing
member for air discharge outlet (option) must
be used to close off the unused outlet(s).
Wireless remote controller and signal
receiver unit are sold as a set.
Cooling only
25°
Auto-swing
between 25° and 60°
" " denotes piping direction.
Drain piping
"
" denotes sealing member for air discharge
outlet (option) .
BRC7E531W
BRC7E530W
Signal receiver unit
(Installed type)
Work & Servicing
60°
Settable to 5 different levels
between 0° and 35°
1 pattern
A signal receiver must be added to the indoor unit.
Cleanliness
25°
35°
2-way flow
Wireless LCD remote controller
Remote controller
35°
1 pattern
Note: Remote controller cable not
included. Cables must be
procured locally.
Comfort
Settable to 5 different levels
between 0° and 60°
0°
Auto-swing
between 0° and 35°
4-way flow
Quiet
(Wired Remote Controller)
60°
0°
Multi-Flow System
Navigation Remote Controller
Heat pump
0°
Auto-swing
between 0° and 60°
Note: This angle above is provided as a guide. It may differ depending on the installation site.
Note: Remote controller cable not
included. Cables must be
procured locally.
Cooling only
Draft
prevention
setting
5-levels air direction setting
0°
60°
600 mm
BRC1C61
Airfow angle can be adjusted
in accordance with room
conditions.
Auto-swing
700 mm
Wired LCD remote controller
0°
575 mm
FFQ25/35/50/60BV1B
Option
Accessory required for indoor unit.
Horizontal flow
*5
*5
60B
Note : Anechoic chamber conversion value, measured according to JIS
parameters and criteria. During operation these values are somewhat higher
owing to ambient conditions.
Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve
comfort level, closer to the target area at the wired remote control.
This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Hot start (after defrost)
Uncomfortable cold air draft is avoided when heating operation starts
or when switching to heat after defrosting.
Switchable fan speed: High/Low
High setting provides maximum reach while low setting minimises drafts.
Drain pump is equipped
as standard accessory
with 750 mm lift.
750 mm
14
CEILING SUSPENDED TYPE
Comfortable airflow travels
throughout the room
New 140 model
provides greater
capacity for large
spaces
Cooling only / Heat pump
FHQ35BVV1B
FHQ50/60BVV1V
FHQ60BVV1G
FHQ71/100/125BVV1B
FHQ140CAVEB(A)
The technology of the DC fan motor,
wide sirocco fan, and large heat
exchanger combine for greater
airflow and quiet operation.
FHQ71BV
Flap neatly closes when not in
use.
NEW
FHQ140CA
Fresh white colour.
Installable on
ceilings 4.3 m high
Option
Accessory required for indoor unit.
Wired LCD remote controller
Connection to a centralised control
system is available, without option.
Note: Remote controller cable not
included. Cables must be
procured locally.
Drain pump kit (option) includes a
silver ion antibacterial agent that
assists in preventing the growth of
slime, bacteria, and mould that
cause smells and clogging.
Navigation Remote Controller
(Wired Remote Controller)
BRC1E62
Note: Remote controller cable not
included. Cables must be
procured locally.
Comfortable
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
Cooling only 35-125BV BRC7EA66
Auto swing (up and down) and louvers (left
and right by hand) bring comfort to the room
BRC7GA56
140CA
35-125BV BRC7EA63W
Heat pump
BRC7GA53
140CA
35-125BV
Louver manually
adjusts for straight
or wide angle airflow
140CA
Signal receiver unit (Installed type)
Wireless remote controller and signal receiver
unit are sold as a set.
Installable on ceilings 3.5 m high (FHQ35-125BV)
Features
15
*7
*8
*8
*8
*8
*9
•
•
*10
*7
*12
• •
• •
*6
*7
*7
• •
• • • • •
• • • • • • • •
---
*5When RXS35 is used, applicable when outdoor temperature is from 10 to 46°CDB
*1FHQ35-125BV: 2 step, FHQ140CA: 3 step
*2Installable on max. 3.5 m (35-125BV), 4.3 m (140CA) high ceiling
*6Applicable to RZR outdoor units
*8Applicable when BRC1E62 is used
*3Applicable when wired remote controller is used
*7Applicable to RZQ outdoor units
*9Applicable when BRC1C61 is used
*4Applicable to RKS outdoor units when outdoor temperature is from 10 to 46°CDB
*10Option
Anti corrosion treated
heat exchangers
*5
*6
Fresh air intake kit
•
*11
DIII-NET communication
standard
*3
*6
Options Others
Interlock control
*2
*10
Central remote control
*9
Auto-cooling/heating
change-over
Control by 2 remote
controllers
Group control by 1 remote
controller
External command
control
*8
Auto-restart
*8
Control features
Self-diagnosis function
*8
Emergency operation
*8
Low gas pressure
detection
On/Off timer
*6
Filter sign
Weekly schedule timer
Off timer (programmed)
*4
Long-life filter
Setpoint range set
---
Pre charged for
up to 30 m
Pre charged for
up to 10 m
Setpoint auto reset
*3
Drain pump mechanism
Night quiet operation
*2
Anti-bacterial air filter
Year-round cooling
applicable
•
•
Hot start (after defrost)
*1
Programme "Dry"
Switchable fan speed
*1
Two selectable
temperature-sensors
•
• •
---
High ceiling application
Heat pump
Draft prevention function
(heating)
Auto swing
Cooling only
Work & Servicing
Two selectable temperature-sensors
*13
*13
*14
---
---
*14
*11Applicable to RKS outdoor units
*12Applicable to RXS outdoor units
*13FHQ140CA only
*14For the outdoor units
Both indoor unit and wired remote controller (option) contain
temperature- sensors. Temperature sensing can be set at the unit or,
to further improve comfort level, closer to the target area at the wired
remote control. This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled
from another room.
**Wireless remote controller does not have a temperature-sensor.
Switchable fan speed: High/Low (FHQ35-125BV)
dB(A)
Indoor unit
High
Middle
Low
35BVV1B
50/60BVV1V
60BVV1G
71BVV1B
100BVV1B
125BVV1B
140CA
37
39
39
39
42
44
46
-------------
32
35
35
35
37
39
38
42
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During
operation these values are
somewhat higher owing to
ambient conditions.
Uses quiet stream fan and other quiet
technologies.
(FHQ35-125BV)
Turbulent flow
is reduced
Straightening plate
Quiet stream fan
Installation flexibility for
freedom of design
Flexible installation
The unit fits more snugly
into tight spaces.
30 mm
30 mm
or more
or more
*Water used in the test-run can now be drained from the
air discharge opening rather than from the side as was
formerly the case.
3 fan speeds: High/Middle/Low
BRC1C61
Remote controller Cleanliness
Sound operation has been reduced on the
exposed ceiling suspended type unit.
High/Middle/Low : 46/42/38 dB(A)
Sophisticated design
Comfort
Quiet operation
Drain pump kit (option) can
be easily incorporated
Drain pipe connection can be done
inside the unit. refrigerant and drain
pipe outlets are at the same opening.
600
mm
Drain pump kit
(built inside
main unit)
All wiring and internal servicing can be done
from under the unit
Pipes more easily rigged
Low gas pressure detection
Easy maintenance
Long-life filter lasts about 1 year*
* For dust concentration of 0.15 mg/m3
Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller (filter
sign).
Non-flocking flap
Condensation does not easily form on and
dirt does not cling to non-flocking flap.
Non-flocking flap
It is easy to clean.
Easy-clean, flat surfaces
Oil resistant grille
Programme "Dry"
Oil-resistant plastic is used for the air suction grille. This satisfies
durability in restaurants and other similar environments.
Dehumidification is a microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification
is not suitable for kitchens or other harsh environments.
16
CEILING MOUNTED SLIM DUCT TYPE
CEILING MOUNTED BUILT-IN TYPE
Suitable for tight ceiling spaces
spaces.
Clever and compact mini ducted unit
provides comfort and flexibility
Option
Heat pump
FDXS25/35/50/60CVMA
Option
Heat pump
Accessory required for indoor unit
Wired LCD remote controller
FBQ50/60/71BV1A
Wired LCD remote controller
Accessory required for indoor unit
BRC1C61
BRC944B2
Note: 3 m (BRCW901A03) or
8 m (BRCW901A08) length
wired remote controller
cord is necessary.
Navigation Remote Controller
(Wired Remote Controller)
Standard
BRC1E62
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
Heat pump
ARC433B69
Wireless LCD remote controller
Signal receiver unit
(Separate type)
A signal receiver must be added to the indoor unit.
Wireless remote
controller and signal
receiver unit are
equipped as a set.
Heat pump
Signal receiver unit
(Separate type)
Note: Refer to Engineering data for airflow and External
static pressure characteristics.
Wireless remote controller
and signal receiver unit
are sold as a set.
Smooth Finish
The only visible sign of these unobtrusive units is their discharge grilles.
They fit completely inside the ceiling to maintain the original decor of a
room. Each unit comes with its own wireless remote controller.
Slim Profile
All units share the same low height of just 200 mm. This means it is now
possible to install a unit inside a shallow ceiling cavity with a height of just
240 mm.
Comfortable
Comfortable
To cope with the challenges of L-shaped or U-shaped spaces, it
is possible to install the air discharge unit away from the main unit.
At the same time,
different types of
architectural space
can be kept
comfortable.
L-shaped space
Indoor unit
High
Low
25C
35
35
37
38
31
31
33
34
50C
60C
Long space
dB(A)
Indoor unit
High
Low
50B
60B
71B
33
34
34
29
30
30
The height of the unit is a mere 300 mm. It can be
installed in a
narrow
30 mm
300
ceiling space.
(when access panel
is used.)
Access panel
Provided with condensate drain pump, waking drain
piping easier in
250 mm
awkward
spaces.
Access panel
External static pressure can be set depending on
duct length, presence of high-efficiency filter, and
other installation conditions.
Compact
External static pressure pattern
Compact design of built-in type helps blend
with interior decor.
Height reduced to allow installation in confined spaces.
Features
(Pa)
Indoor unit
High
Standard
Low
50B–71B
88
49
20
External static pressure is set to standard when the unit is shipped from the factory.
Features
•
•
•
•
•
•
•
Anti corrosion treated
heat exchangers
•
Interlock control
External command
control
•
Others
Central remote
control
Group control by 1 remote
controller
*5
Control by 2 remote
controllers
•
Auto-cooling/heating
change-over
•
Auto-restart
*4
Self-diagnosis function
*3
Control features
Filter sign
*3
*3Applicable when BRC1E62 is used
*4Applicable when BRC1C61 is used
Pre charged for
up to 10 m
*3
Drain pump mechanism
*3
Work & Servicing
Mould-proof drain pan
*2
On/Off timer
•
Off timer (programmed)
*1
*1Applicable when wired remote controller is used
*2Applicable when outdoor temperature is from 10 to 46°CDB
Cleanliness
Weekly schedule timer
•
Setpoint range set
•
Setpoint auto reset
Heat pump
Year-round cooling
applicable
*2
Hot start (after defrost)
•
Remote controller
Two selectable
temperature-sensors
•
Programme "Dry"
•
Anti corrosion treated
heat exchangers
•
Comfort
Switchable fan speed
(2 step)
*2
Central remote
control
•
Auto-cooling/heating
change-over
*1
Auto-restart
Hot start (after defrost)
•
Others
Control features
Self-diagnosis function
Programme "Dry"
•
Mould-proof air filter
Auto airflow rate
•
Year-round cooling
applicable
Switchable fan speed
(2 step)
•
*1Applicable when outdoor temperature is from 10 to 46°CDB
*2For the outdoor units
Pre charged for
up to 10 m
Cleanliness Work & Servicing
Comfort
17
U-shaped space
dB(A)
35C
Heat pump
Work & Servicing
Flexibly adapts to shop interiors
Quiet operation
Quiet operation
BRC4C62
*5
*5For the outdoor units
18
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Enhance comfort using cleverly
placed ducts
Increased freedom of design
thanks to variable control
over external static pressure
Cooling only / Heat pump
Comfort airflow achieved in accordance with
conditions such as duct length.
FBQ50/60DV1V
FBQ60/71/100/125/140DV1
When testing standard integrated ceiling units that employ duct
work, much time used to be required to adjust airflow to the right
level. Thanks to the ability provided by Daikin to automatically
perform this troublesome adjustment using a remote controller,
this step is now quick and easy. (Adjust by H tap .)
Easier connection with the centralised
control system
Freely control external static pressure
200 Pa
Set to low static
pressure when ducts
are short.
Use remote controller to adjust airflow
1. Adjust to approximately ±10% of the rated H tap airflow.
2. Once actual operation has begun, adjustment of the rated airflow is not possible.
Using a DC fan motor, the external static pressure can be
controlled within a range of 50 Pa to 200 Pa.
50 Pa
Reduced installation time
Quiet operation
Set to high static pressure for
advanced needs such as when
using dampers and long ducts.
dB(A)
50/60/71D
100D
125/140D
37
32
38
33
40
36
High
Low
Option
Thin, lightweight indoor
unit makes delivery and
installation easy.
Accessory required for indoor unit.
Wired LCD remote controller
BRC1C61
Note: Remote controller cable not
included. Cables must be
procured locally.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
Easy maintenance
Maintenance is easy because the drain pan can be removed.
With a height of only 300 mm, installation is
possible even in buildings with narrow ceiling
spaces.
Navigation Remote Controller
(Wired Remote Controller)
Clean
Silver ion anti-bacterial drain pan
BRC1E62
300mm
Mould-proof drain pan includes a silver ion antibacterial agent
that assists in preventing the growth of slime, bacteria, and mould
that cause smells and clogging.
Note: Remote controller cable not
included. Cables must be
procured locally.
Indoor unit
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
BRC4C64
BRC4C62
Cooling only
Heat pump
50/60/71D
Height (mm)
Width
(mm)
Depth
(mm)
Machine weight (kg)
100D
125D
140D
300
1,000
Comfortable
1,400
700
36
Two selectable temperature-sensors
46
Drain pump is equipped as standard accessory
with 700 mm lift.
Signal receiver unit
(Separate type)
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another
room.
**Wireless remote controller does not have a temperature-sensor.
700 mm
Wireless remote controller and signal
receiver unit are sold as a set.
Both indoor unit and wired remote controller (option) contain
temperature- sensors. Temperature sensing can be set at the unit
or, to further improve comfort level, closer to the target area at the
wired remote control.
This feature requires initial setting by the installer.
Features
*1Applicable when wired remote controller is used
*2For the outdoor units
*3Applicable when BRC1E62 is used
19
• •
• •
•
•
*2
*2
• • • • • • •
• • •
• • • • • • • • • • •
---
Anti corrosion treated
heat exchangers
High efficiency filter
DIII-NET communication
standard
*5
Option Others
Interlock control
*5
*2
Central remote
control
*2
External command
control
• •
*5
Group control by 1 remote
controller
*5
*4
Control by 2 remote
controllers
*4
*3
Auto-cooling/heating
change-over
Anti-bacterial air filter
*3
*3
Auto-restart
On/Off timer
*3
*3
Control features
Self-diagnosis function
Off timer (programmed)
*3
*3
Emergency operation
Weekly schedule timer
*3
*2
Low gas pressure
detection
Setpoint range set
*2
Filter sign
Setpoint auto reset
---
Long-life filter
Night quiet operation
---
*1
Drain pump mechanism
Year-round cooling
applicable
*1
Pre charged for
up to 30 m
Hot start (after defrost)
• •
• •
Two selectable
temperature-sensors
Heat pump
Programme "Dry"
Switchable fan speed
(2 step)
Cooling only
Work & Servicing
Cleanliness
Silver ion anti-bacterial
drain pan
Remote controller
Comfort
*2
*2
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms
simultaneously, the air discharged into each
room must be circulated back to the air
conditioner. To achieve this, a ventilation
duct should be installed for each room or one
of the indicated ventilation grilles should be
installed on the partitioning wall or under the
door between the rooms.
Door-installed
ventilation grille
Partitioning wall
Wall-installed
ventilation grille
Under-door cutout
Ventilates air through
the partitioning wall.
(See right)
Ventilation grille
Ventilation grille
Under-door cutout
Note: The under-door cutout method should be used only when there is a small volume of airflow.
*4Applicable when BRC1C61 is used
*5Option
20
Floor Standing Type
New airflow control for
more comfort
New comfortable airflow control
1) Left and right directions (by remote controller)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
(Applicable when BRC1E62 is used.)
Pattern 1
Cooling only / Heat pump
Wide swing toward the front
Pattern 2
Swing on the left side
Pattern 3
Swing on the right side
FVQ50/60CVE
FVQ71/100/125/140CVEB
When installed in the center of a wall.
When installed in the corner of a room.
2) Up and down directions (by hand)
Independent up-and-down airflow directions facilitate even room temperature and help save energy.
BRC1E62
can be
incorporated
into the
main unit.
Freely select
both up and
down airflow
direction with
8-louver
(horizontal
blade)
operation.
Example applications
New unit
Upper louver (1)
Lower interlocking louvers (2)
Lower louver (1)
Each set of louvers to
can be independently
adjusted. (Manual adjustment)
Comfortable fan speed
control
Option
Accessory required for indoor unit.
Wired LCD remote controller
Switchable fan speed:
High/Middle/Low and Auto
BRC1C61
("Auto" is applicable when BRC1E62 is used.)
Note: Remote controller cable not
included. Cables must be
procured locally.
(Wired Remote Controller)
High fan speed mode (applicable for FVQ50-100)
BRC1E62
To carry airflow to the far side of the room, airflow rate can be
increased 5% or 10% depending on the installation condition or
customer's request. (Field setting by remote controller.)
Note: Remote controller cable not
included. Cables must be
procured locally.
Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt
and uncomfortable changes in air temperature.
Features
*1
*1
*1
*1
*5
21
*4
*4
*4
Interlock control
*4
*4For the outdoor units
*5Applicable when BRC1C61 is used
• •
• •
Others
DIII-NET communication
standard
Anti corrosion treated
heat exchangers
• •
*4
Central remote control
*3
*1Applicable when BRC1E62 is used
*2Applicable for FVQ50-100
*3Applicable when wired remote controller is used
•
•
External command
control
*5
Auto-cooling/heating
change-over
Control by 2 remote
controllers
Group control by 1 remote
controller
*1
Auto-restart
*1
Control features
Self-diagnosis function
*1
Emergency operation
On/Off timer
*1
Filter sign
Off timer (programmed)
*4
Low gas pressure
detection
Weekly schedule timer
---
Long-life filter
Setpoint range set
---
Pre charged for
up to 30 m
Setpoint auto reset
*3
Anti-bacterial air filter
Night quiet operation
*2
Year-round cooling
applicable
*1
•
•
Hot start (after defrost)
*2
Two selectable
temperature-sensors
*1
Programme "Dry"
High fan speed mode
Switchable fan speed
(3 step)
• • •
• • •
Auto airflow rate
Heat pump
Independent up-and-down
airflow
Auto swing
Cooling only
Work & Servicing
Cleanliness
• • •
• • • • • •
• • • • • • • • • •
---
Quiet operation
dB(A)
Indoor unit
50/60/71C
100C
125C
140C
High
43
50
51
53
Middle
41
47
48
51
Low
38
44
46
48
Auto airflow rate is selectable.
Navigation Remote Controller
Remote controller
Turning louvers
and upward
and leaving
and horizontal
will reduce
uneven room
temperature.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature.
Comfort
When cooling
Upper interlocking louvers (4)
*4
*4
Energy saving
A DC fan motor improves efficiency.
Quick and easy installation
and maintenance
Lightweight indoor unit
Enables smooth transport and installation of the indoor unit.
Indoor unit
50/60/71C
Weight
39
100C
125C
(kg)
140C
47
Long-life filter lasts about 1year *
maintenance not required
* For dust concentration of 0.15 mg/ m3
Employs a safety lock function of suction grill.
The grill will not open even upon impact.
Easier connection with the centralised control
system.
22
OUTDOOR UNIT
Technology for energy efficiency
Compact Outdoor unit
The high efficiency compressor to
achieve a high COP
1
Compressor equiped with Reluctance DC motor
Daikin DC Inverter models are equipped with the Reluctance DC
motor for compressor.
The Reluctance DC motor uses 2 different types of torque,
neodymium magnet*1 and reluctance torque*2.
This motor can save energy because it generates more power with a
smaller electric power than an AC or conventional DC motor.
RZQ50KBV1V/KBV4A
RZQ60KBV1V/KBV4A
RZQ71KCV4A
RZR100LUY1
RZR125LVVM/LUY1
RZR140LVVM/LUY1
RZR100LVVM
Easy installation and maintenance
Pre charged for up to
30 metres
4-direction piping offers
greater layout freedom
If refrigerant piping length does not exceed
30 m, there is no need for on-site gas
charging.
(not applicable for RZR50-71)
Allowed refrigerant piping length
and level difference
RZR50-140LU/LV
RZQ100-140KC
RZQ50/60KB
RZQ100-140HA
RZQ71KC
Pre
charged1
Max.
length
(Refrigerant recovery function)
A pump-down switch is provided to
make it easier to collect refrigerant if
the unit is to be moved or layout
modified.
75 m
50 m
(Equivalent length (Equivalent length
70m)
90m)
Max. level
difference
(RZR50-71 only)
Facilitates pump down
30 m
30 m
Note : 1Additional refrigerant charging is required if the
refrigerant pipe is longer than the length.
Cooling only
Heat pump
Rated2
Night Quiet
Mode
RZQ50/60KB
48
44
RZQ71KC
48
44
RZR100LU/LV RZQ100KC/HA
49
45
RZR125LU/LV RZQ125KC/HA
50
45
RZR140LU/LV RZQ140KC/HA
50
46
8 hours
RZR71LV
Note
23
:1
Anechoic chamber conversion value, measured according to
JIS parameters and criteria. During operation these values
are somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.
Load (%)
Operation
Sound3 (dB(A))
50
RZR50/60LU/LV
0
49
0
60
Small load
Low capacity
90
120
Large load
High capacity
RZR50/60LU/LV, RZR71/100LVVM
RZQ50/60KB, RZQ71KC
2
Construction
Swing bushing
Refrigerant gas
>> Smooth sine wave DC inverter
Use of an optimised sine wave
smoothes motor rotation, further
improving operating efficiency.
Non-treated fin
Aluminium
Anti corrosion
treated heat
exchangers
Hydrophilic film
Aluminium
Corrosion resistant
acrylic resin
Sine wave DC inverter
RZR125/140LVVM, RZR100/125/140LUY1
RZQ100/125/140KC, RZQ100/125/140HA
Suction
>> Swing compressor
>> The structural scroll
Energy savings is
realised, eliminating
the friction and the
leakage of
refrigerant gas.
Sucked gas is compressed in the
scrolling part before the heated motor,
so that the machine compress
Discharge
the non-expanded gas, resulting
in high efficiency compression.
Piston by incorporated
blade and roller.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
(not applicable for RZR50-71)
With the bent
blade edge
Scroll section
Motor section
Without the bent
blade edge
These two features work to reduce noise. Guides
are added to the bell mouth intake to reduce
turbulence in the airflow generated by fan suction.
The Aero Spiral Fan features fan blades with the
bent blade edges, further reducing turbulence.
Demand Control
Function
The maximum capacity is maintained within
a set level of power consumption, which
makes it possible to keep comfort and
effective demand control.
10 hours
30
Rotational speed (rps)
Escaping eddies are sucked in by
the bent blade edges, reducing
overall turbulence.
(RZR100-140 and RZQ only)
100
AC motor
3
DC fan motor
Efficiency improved in all areas compared to AC
motors, especially at low speeds.
DC fan motor structure
Limitation
Power
consumption
1
Capacity (%)
Peak in outdoor temperature
70
50
Durability
Heat exchange fins provided with
anti-corrosion treatment
The Automatic night quiet mode will initiate 8 hours after the peak temperature is
reached in the daytime, and normal operation will resume 10 hours after that.
Conventional
DC motor
More than 20%
60
Imitating the performance
of the swan
Low gas pressure
detection function
1
80
*1. A neodymium magnet is approximately 10 times stronger
than a standard ferrite magnet.
*2. The torque created by the change in power between the iron
and magnet parts.
Φ550
V-cut propeller fan
2
Reluctance
DC motor
Reluctance DC Motor
90
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory.
As the bottom frame is subject to corrosion,
corrosion-proof galvarium steel plate is adopted
to enhance the durability.
Night time quiet operation function
Sound level (dB(A))
Through use of a V-cut propeller fan
that imitates the efficiency of the
swan, a migratory bird, airflow
becomes smooth and loss is reduced.
*Pump-down function is available for
pre-charged refrigerant amount.
Effective gas monitoring reduces the
labor required for operation,
maintenance, and repairs.
Reducing noise will reduce capacity slightly.
RZQ100HAY4A
RZQ125HAY4A
RZQ140HAY4A
Energy saving
The outer panel for the piping
connection part of the front, right side
and backside
can be
removed and
is easier for
post-installatio
Separation
n piping work.
available
Long piping length
RZQ100KCV4A
RZQ125KCV4A
RZQ140KCV4A
Motor efficiency (%)
RZR50LUV1V/LVVM
RZR60LUV1V/LVVM
RZR71LVVM
3
Rated
45 Quiet mode
8:00
12:00 16:00 20:00
Note : 3In case of RZR100
Quiet mode
0:00
4:00
8:00
8:00
12:00
16:00
* Required for KRP58M51 (Option)
20:00 Time
24
LCD REMOTE CONTROLLER
Optional accessory
Easy-to-read LCD remote controller allows various system
control configurations and can control multiple indoor units.
Remote controller options are shown on the page introducing each indoor unit model.
Navigation Remote Controller
(Wired Remote Controller BRC1E62)
Wired LCD remote controller
The rubber switch and the
oil-resistant plastic casing are
adopted for durability.
This simple, modern designed remote controller with fresh
white colour matches your interior design. Operation is
much easier and smoother, just follow the indications on
the navigation remote controller.
NEW
Wired remote controller has
built-in temperature-sensor
Easy to read because of large LCD screen.
Only 17 mm thick. Can be
installed either recessed or
exposed.
(Applies to wired remote controllers (BRC1C61/1E62))
Enables temperature sensing closer to target
area for improved comfort. (When using remote
control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
Facilitates maintenance and repair
All initial settings can be set from the remote
controller. After interior construction is complete,
ceiling mounted cassette type can be remotely
set without having to use stepladder access for
manual setting.
BRC1C61
Setting contents: High ceiling use, air direction, filter type, address
Clear Display
Dot matrix display
LCD wireless remote controller
Backlight
display
A combination of fine dots
enables various icons.
Large text display is easy to
see.
The wireless remote controller is
supplied in a set with a signal
receiver.
Signal receiver unit is contained
inside decoration panel or indoor
unit
Shape of signal receiver unit
differs according to the indoor
unit.
BRC7F633F
Energy saving
NEW
Setpoint auto reset
Restaurant sample
Temperature is set to 27ºC
Wireless remote
controller
NEW
- Even if the set temperature is changed, it returns to the preset temperature
after apreset period of time.
- Period selectable from 30min/60min/90min/120min.
Restaurant opened
for centralised control (group control address is set automatically).
Full tables at lunchtime
Then is lowered to 24ºC for
crowded room
After 30 minutes*
Automatically returns to preset
temperature (27ºC)
Setpoint range set
- Saves energy by limiting the
min. and max. set temperature.
- Avoids excessive heating or
cooling.
- This function is convenient when
the remote controller is installed
at a place where any number of
people may operate it.
Signal receiver unit
(For ceiling mounted
cassette type)
Note: The signal receiver unit shown in the
photograph is for mounting inside
the decoration panel of the ceiling
mounted cassette type.
CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
Airflow / swing display
- 5 actions per day can be scheduled for each day
of the week.
- The holiday function will disable schedule timer
for the days that have been set as holiday.
NEW - 3 independent schedules can be set.
Easily adaptable to large-scale, high-function,
centralised remote control systems.
Installing and connecting control wiring between
SkyAir and other Daikin air-conditioning
equipment is easy.
BRC7E530W
BRC7EA66
BRC7EA63W
140CA
BRC7GA56
BRC7GA53
-----
ARC433B69
(standard accessory)
-----
BRC4C62
BRC4C64
BRC4C62
LCD panel shows operating status in letters, numbers, and motion.
Convenience
Weekly schedule
Heat pump
BRC7F632F
BRC7E531W
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
- Sets and saves setting for an increment of time that automatically turns off air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments.
Cooling only
BRC7F633F
35-125BV
COMPACT MULTI FLOW TYPE
CEILING MOUNTED BUILT-IN TYPE
Off timer (programmed)
SkyAir shares common control with
Heat Reclaim Ventilator and the
other Daikin air-conditioning units,
thus simplifying interlocking
operations.
Wireless remote controller for each indoor unit type
CEILING MOUNTED SLIM DUCT TYPE
*Setting possible for after 30, 60, 90, and 120
minutes.
Remote controller is equipped with model name
and failure display functions. This facilitates
service in the unlikely event of a malfunction.
(Applies to wired remote controller (BRC1E62))
Preset temperature / operation mode display
Multilingual display
Display is available in 11
languages.
Programming time display
Self-diagnosis function
Displays auto-swing operating status and setting position of air discharge angle.
Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
(English, German, French, Spanish,
Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
(e.g. summer, winter, mid-season)
25
26
Simultaneous operation system
Simple system provides a diverse assortment LCD
of control
modes.
REMOTE CONTROLLER
Wireless remote controller
(Basic system)
Non-polar, double-core
(max. wiring length 500 m)
Control by 2
remote controllers
Signal receiver unit installed
on indoor unit
Four new types of Multi series
indoor units are now available!
Control by 1 wireless remote
controller and 1 wired remote
controller (See note 2, 3)
For control from 2
locations such as in
room and control room,
exits, etc.
Signal receiver unit installed
on indoor unit
Connects 2 wired remote
controllers (See note 1)
Branch piping kit
Group control
For simultaneous
control of up to 16
indoor units.
Automatic address setting function
Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Control by
external command
Operation and
surveillance is carried out
using the contact signal
from the operation control
box in the building
surveillance (security)
room.
Optional wiring adaptor for
electrical appendices is necessary
Interlock control
with Heat Reclaim
Ventilator
Interface adapter for SkyAir series (option) is
required (See note 4)
Interface adapter for SkyAir series (option) is
required (See note 4)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Can be operated simultaneously
or independently by remote controller
(set by ventilation mode)
Can be operated simultaneously
by remote controller
(set by ventilation mode)
Central remote controller (option)
Zone link control by
centralised control.
Central remote controller (option)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Heat Reclaim Ventilator for indoor units within a zone are operated by
interlocking Can also be operated independently by remote controller.
FHQ60BVV1G X2
FHQ71BVV1B X2
specifications Page 31
specifications Page 33
Branch piping kit
Central remote controller (option)
Centralised control of
up to 64 indoor groups
from remote location
up to 1 kilometer away.
Link by remote
controller group control.
FCQ60/71LUV1 X2
Optional wiring adaptor for
electrical appendices is necessary
Central remote controller (option)
Centralised remote
control
Branch piping kit
Heat Reclaim Ventilator for indoor units within a
zone are operated by interlocking
FBQ60/71DV1 X2
specifications Page 34
specifications Page 35
Twin Multi for comfort and
economy
Lower installation cost than
individual pair type
Reduced outdoor unit
installation space
Distributed indoor units
enhance comfort
Central remote controller
DCS302CA61 (Option)
Unified on/off controller
DST301BA61 (Option)
Centralised control, with setting as
simple as it is with a standard
remote controller, of up to 64 groups
(1,024 indoor units) is possible.
Centralised control of on/off by
group or all at once for up to 256
indoor units.
Interface adaptor for SkyAir series
Enables centralised control via connection
to a high-speed, DIII-NET communication
system, adopted for the Daikin VRV system.
DTA112BA51 (Option)
Unified control of weekly schedule
for up to 1,024 indoor units.
Schedule timer sets on/off time in 1 minute units
to be executed twice a day for a week at a time.
Necessary for interface adaptor for SkyAir series with the
central remote control units shown at above.
27
Piping guideline
Schedule timer
DCS301BA61 (Option)
DCS601C51 (Option)
With its high functionality, the full
colour “all-in-one” graphic controller
facilitates management of SkyAir
System in a variety of ways.
The interface adaptor for the SkyAir series is optional except for the
ceiling mounted cassette type <Round Flow>, ceiling suspended
type (140CA only), duct connection middle and high static pressure
type, and floor standing type.
For example, four
indoor units are judiciously
spaced in this wide single-floor
restaurant to deliver comfortable
currents of air to every
corner of the room.
2 sets of
Twin Multi
Note: 1BRC1E62 can connect to BRC1E62 only.
2
It is not possible to use two wireless remote controllers.
3
BRC1E62 cannot connect to wireless remote controller.
4
The ceiling mounted cassette type <Round Flow>, ceiling suspended type (140CA only), duct connection middle and high static pressure type, and floor standing type come standard with
an interface adaptor for SkyAir series.
Easily adaptable to large-scale, high-function, centralised remote control system.
Branch
piping kit
FVQ60CVE X2
FVQ71CVEB X2
Outdoor unit
RZR125/140LVVM
RZR125/140LUY1
Max. piping length
L0
One-way max. piping length
(longest length of liquid piping
or gas piping)
L0 L1 50 m
(In case of L1 L2)
Max. branch piping length
Max. difference of branch
piping length
L1
L2
Refrigerant branch piping
kit for Twin Multi
operation (option)
Indoor
unit
60 m
Indoor unit
L2
L1, L2
20 m
Max. level difference between
indoor units
H1
0.5 m
Max. level difference between
outdoor unit and indoor units
H
30 m
Page 43
Branch
piping
Branch piping
L1 L2 10 m
(In case of L1 L2)
KHRP58P216T
H1
Control by 1
remote controller
Wired remote controller
H
Control pattern
Twin Multi operation
L1
Main piping
L0
Outdoor unit
28
Abundance of functions that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Comfort
High-ceiling application
Auto-swing
Delivers comfortable
air-conditioning to all areas, near to
and far from the air-conditioner.
The air flow direction can be
fixed at your desited angle
by the remote controller.
Swing pattern selection
(standard, ceiling soiling prevention)
Delivers
air-conditioning
comfort all the way
down to the floor in
air-conditioning zones
with high ceilings.
You can freely set 2 air discharge setting by remote controller.
(1) Air direction in
standard
setting
(2) Air direction in
ceiling soiling
prevention
setting
Draft prevention function (heating)
To prevent cold air drafts, automatically adjusts airflow to near horizontal
position when heating initially starts or when the thermostat turns off.
Independent up-and-down airflow
Independently adjust (manually) the eight horizontal blade louvers in
both up and down directions to achieve an airflow that reduces
uneven room temperature.
Switchable fan speed
High setting provides maximum reach while low setting minimises drafts.
Auto airflow rate
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature.
High fan speed mode
You can increase fan speed approximately 10% higher than the "high" setting.
Note:When units are installed on high ceilings, depending on the model, various
restrictions concerning maximum height, air discharge direction, and choice of
options may apply.
Two selectable temperature-sensors
Temperature-sensors are included in the indoor unit and optional
wired remote controller. Temperature sensing closer to target area is
possible to further increase the comfort level.
Use the temperature-sensor in the
indoor unit when controlling air
conditioning from another room.
Note: Wireless remote controllers have no
temperature-sensor.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Work and Servicing
Drain pump mechanism
Steeper gradient realises more
efficient condensate drainage.
High-lift is especially useful for long
lengths of drain piping.
Pre charged for up to 30 metres
If refrigerant piping length does not exceed 30 m, there is no need
for on-site gas charging.
*Applicable to RZR/RZQ series.
RKS/RXS series: 10 m
Cold air flow is avoided when heating operation starts or when
switching to heat after defrosting.
Year-round cooling applicable
Efficient cooling even in winter when the indoor temperatures are
higher than those outside, such as in underground public spaces or
offices with many computers.
Maintenance is not required for one year (two years when a ceiling
mounted cassette type is used).
Filter sign
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD. When using
a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature. Useful for reducing
uncomfortable humidity without uncomfortable cooling of the room.
Night quiet operation
The Automatic night quiet mode will initiate 8 hours after the peak
temperature is reached in the daytime, and normal operation will
resume 10 hours after that.
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the power cut
when electricity is restored.
Auto cool/heat change-over (Heat pump only)
Detects difference in preset temperature and actual room
temperature and automatically switches to cooling or heating
accordingly.
Setpoint auto reset
Even if the set temperature is changed, it returns to the preset
temperature after a preset period of time.
Off timer (programmed)
Sets and saves setting for an increment of time that automatically
turns off air conditioner after a preset period of time for each time
operation starts.
Setpoint range set
Saves energy by limiting the minimum and maximum set
temperatures. Avoids excessive heating and cooling.
Control by 2 remote controllers
Using 2 remote controllers you can operate the equipment locally or
from a remote location.
Note: When a wireless remote controller is used, remote control by two remote
controllers is not possible.
Group control by 1 remote controller
Remote Controller
On/Off timer
Operation starts when the preset time of the ON timer elapses and
stops when the preset time of the OFF timer elapses.
High-efficiency filter unit
Two types are available: 65% and 90% colorimetry.
Ultra long-life filter
Requires no maintenance for about 4 years* (10,000h) in stores and
offices.
Cleanliness
Anti-bacterial air filter
Mould-proof air filter
Sanitary filter has mould-resistant treatment.
29
Silver ion anti-bacterial drain pan
Mould-proof drain pan includes a silver ion antibacterial agent that assists in
preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Mould-proof drain pan
Mould-proof drain pan prevents growth of mould in highly humid conditions.
If there is a malfunction elsewhere in the system, the fan or
compressor can still be operated.
Self diagnosis function
The operating parameters of indoor and outdoor units, and sensor
data at critical locations throughout the system, are constantly
monitored using a microcomputer. To facilitate quick response in the
event of a malfunction, a message appears on the LCD of the remote
controller and an LED on the unit illuminates.
External command control
Operation and surveillance is carried out using the contact signal from
the operation control box in the building surveillance (security) room.
*Required for KRP58M51 (Option)
Central remote control
Optional central remote controller enables centralised control of up to
1024 indoor units (64 groups) from up to 1 kilometer away.
Interlock control
Enables interlocking control with external equipment such as Heat
Reclaim Ventilator.
DIII-NET communication standard
Standardly equipped interface enables connection to centralised
control system without need of an adaptor.
Options
*For dust concentration of 0.15 mg/m3
The Air filter has a anti-bacterial treatment to help prevent the growth
of bacteria and mould on it.
Insufficient gas charging is normally hard to detect. During
post-installation trials and regular inspection procedures, the
refrigerant level is monitored by microprocessor to maintain proper
gas pressure. Reliability is assured and maintenance and inspection
can be carried out more quickly.
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings must all
be the same and on/off will be simultaneous.)
Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per day for
each day of the week. Not only can the time be set for the operation
ON setting, but also the temperature.
Low gas pressure detection
Control features
Applicable for wall mounted type
Programme "Dry"
Daikin's innovative air discharge mechanism keeps airflow away from
the ceiling. Ceiling cleaning is less frequently required.
Emergency operation
Long-life filter
Auto-restart
Hot start (after defrost)
Ceiling soiling prevention function
Fresh-air intake kit
You can provide air-conditioning with fresh air from outside. Convenient
for places where a ventilation fan cannot be installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should,
as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional
PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is
limited to 10% of the maximum airflow rate of the indoor unit. Introducing
higher quantities will increase the operating noise and may also influence
temperature sending.
Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat
exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.
30
SPECIFICATIONS
CEILING MOUNTED CASSETTE TYPE
Model
Name
Power supply
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
100
125
100
125
RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1
Cooling1
kW
5.0
(2.3-5.6)
5.8
(2.6-6.3)
1.30
3.84
1.57
3.70
1 Phase, 220–240 V, 50 Hz
10.0
7.1
(5.0-11.2)
(3.2-8.0)
1.99
3.57
2.78
3.60
Unit
Decoration panel
Sound level (H/L)3
Unit
Dimensions
(HXWXD)
Decoration panel
Machine
weight
Unit
Decoration panel
Certified Operation range Cooling
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Liquid (Flare)
Piping
connections
Gas (Flare)
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
m3/min
cfm
dB(A)
mm
21/13.5
741/477
35/28
256X840X840
mm
kg
kg
21
32/20
1,130/706
43/32
kg
dB(A)
dB(A)
mm
kg
°CDB
mm
mm
14.0
(6.2-15.4)
3.68
3.40
----------
4.91
2.85
2.78
3.60
Fresh white
32/20
33/22.5
1,130/706
1,165/794
44/34
44/36
43/32
298X840X840
50X950X950
24
5.5
°CWB
kW
12.5
(5.7-14.0)
3 Phase, 380–415 V, 50 Hz
12.5
10.0
14.0
(5.7-14.0)
(5.0-11.2)
(6.2-15.4)
3.68
3.40
4.91
2.85
Hermetically sealed swing type
1.35
1.76
3.15
(Charged for 30 m)
2.7
(Charged for 30 m)
3.7
(Charged for 30 m)
48
44
595X845X300
43
49
50
49
50
45
1,170X900X320
92
97
46
97
21 to 46
o/ 9.5
o/ 15.9
mm
mm
m
m
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
Heat insulation
FFQ60BV1B
Outdoor unit
RKS25AVMG
RKS35AVMG
RKS50AVMG
RKS60AVMG
Power supply
Outdoor unit
Power consumption
Cooling1
35
1 Phase, 220–240 V, 50 Hz
kW
kW
W/W
COP
Unit
Decoration panel
m3/min
Airflow rate (H/L)
2.5
(1.2-3.0)
3.4
(1.2-3.7)
4.7
(1.7-5.6)
5.8
(1.7-6.0)
0.73
3.42
1.10
3.09
1.62
2.90
2.07
2.80
12/8
423/282
36/27
15/10
529/353
41/32
---------White
Colour
cfm
Outdoor
unit
2.7
(Charged for 30 m)
46
FFQ50BV1B
3.1
1.6
(Charged for 30 m)
45
990X940X320
78
FFQ35BV1B
33/22.5
1,165/794
44/34
44/36
Hermetically sealed scroll type
1.8
2.4
3.1
2.4
2.03
60
FFQ25BV1B
Indoor
unit
14 to 25
Ivory white
1.12
50
Indoor unit
Cooling capacity1
Rated (Min. - Max.)
25
Cooling only
Model
Name
140
Outdoor unit
kW
Sound level3
140
FCQ50LUV1V FCQ60LUV1V FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1
W/W
Drain
71
Indoor unit
Airflow rate (H/L)
Outdoor
unit
60
Outdoor unit
Colour
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Cooling only
50
Sound level (H/L)2
Dimensions Unit
(HXWXD)
Decoration panel
Machine weight Unit
Decoration panel
Certified operation range
Colour
Compressor Type
Motor output
Refrigerant charge (R-410A)
Sound level2
Dimensions (HXWXD)
Machine weight
Certified operation range
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
dB(A)
mm
mm
kg
kg
°CWB
9/6.5
317/229
29.5/24.5
286X575X575
55X700X700
17.5
2.7
14 to 23
Ivory white
Hermetically sealed swing type
kW
0.6
1.0
(Charged for 10 m)
kg
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
10/6.5
353/229
32/25
46
1.1
1.5
(Charged for 10 m)
47
550X765X285
34
49
735X825X300
47
10 to 46
o/ 6.4
o/ 9.5
o/ 12.7
VP20 (I.D o/ 20XO.D o/ 26)
o/ 18.0 (Hole)
20
15
30
20
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Twin Multi
Model
Name
Power supply
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
125
140
125
140
Indoor unit
FCQ60LUV1x2
FCQ71LUV1x2
FCQ60LUV1x2
FCQ71LUV1x2
Outdoor unit
RZR125LVVM
RZR140LVVM
RZR125LUY1
RZR140LUY1
Outdoor unit
kW
Cooling1
kW
W/W
Colour
Sound level (H/L)3
Unit
Dimensions
(HXWXD)
Decoration panel
Machine
weight
Unit
Decoration panel
Certified Operation range Cooling
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound level3 Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
14.0
(6.2-15.4)
12.5
(5.7-14.0)
14.0
(6.2-15.4)
3.68
3.40
4.91
2.85
3.68
3.40
4.91
2.85
---------m /min
cfm
dB(A)
mm
mm
kg
kg
kW
kg
dB(A)
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
3.1
3.7 (Charged for 30 m)
3.15 (Charged for 30 m)
50
45
46
45
1,170X900X320
97
21 to 46
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
31
Indoor unit
Power supply
Outdoor unit
46
FHQ35BVV1B
Outdoor unit
Power consumption
Cooling
COP
Colour
Indoor
Airflow rate (H/L)
unit
14 to 25
Ivory white
Hermetically sealed scroll type
3.1
2.4
2.4
Model
Name
Cooling capacity1
Rated (Min. - Max.)
Fresh white
21/13.5
741/477
35/28
256X840X840
50X950X950
21
5.5
3
Cooling only
35
12.5
(5.7-14.0)
°CWB
CEILING SUSPENDED TYPE
3 Phase, 380–415 V, 50 Hz
Unit
Decoration panel
Airflow rate (H/L)
Outdoor
unit
1 Phase, 220–240 V, 50 Hz
RKS35AVMG
kW
1
Sound level (H/L)2
Dimensions (HXWXD)
Machine weight
Certified operation range
Colour
Outdoor
Compressor Type
unit
Motor output
Refrigerant charge (R-410A)
Sound level2
Dimensions (HXWXD)
Machine weight
Certified operation range
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
W/W
m3/min
cfm
dB(A)
mm
kg
°CWB
kW
kg
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
1 Phase, 220–240 V, 50 Hz
3.4
(1.2-3.7)
1.05
3.24
White
13/10
458/353
37/32
195X960X680
24
14 to 23
Ivory white
Hermetically sealed swing type
0.6
1.0 (Charged for 10 m)
47
550X765X285
34
10 to 46
o/ 6.4
o/ 9.5
VP20 (I.D o/ 20XO.D o/ 26)
o/ 18.0 (Hole)
20
15
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
32
SPECIFICATIONS
CEILING SUSPENDED TYPE
Model
Name
Indoor unit
Power supply
Outdoor unit
kW
Cooling1
Power consumption
COP
Colour
Indoor
Airflow rate (H/M/L)
unit
Sound level (H/M/L)3
Outdoor
unit
Dimensions (HXWXD)
Machine weight
Certified operation range
Colour
Compressor Type
Refrigerant charge
(R-410A)
Motor
output
Refrigerant charge (R-410A)
50
60
FHQ50BVV1V
FHQ60BVV1V
71
100
100
140
125
125
kW
W/W
5.0
(2.3-5.6)
1.60
3.13
m /min
cfm
dB(A)
mm
kg
°CWB
3
kW
kg
Sound level3 Cooling
dB(A)
Night quiet mode dB(A)
mm
Dimensions (HXWXD)
kg
Machine weight
Certified operation range
°CDB
mm
Piping
Liquid (Flare)
connections
mm
Gas (Flare)
mm
Drain
Indoor unit
mm
Outdoor unit
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation
FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ140CAVEB FHQ100BVV1B FHQ125BVV1B
1.12
5.8
(2.6-6.3)
1.99
2.92
1 Phase, 220–240 V, 50 Hz
7.1
10.0
(3.2-8.0)
(5.0-11.2)
2.50
2.84
White
12.5
(5.7-14.0)
3.51
2.85
13.3
(6.2-15.4)
3 Phase, 380–415 V, 50 Hz
10.0
12.5
(5.0-11.2)
(5.7-14.0)
4.55
2.75
4.68
3.51
4.55
2.84
2.85
2.75
Fresh white
White
17/-/14
24/-/20
30/-/25
34/29/24
24/-/20
30/-/25
600/-/494
847/-/706
1,059/-/883 1,200/1,024/847
847/-/706
1,059/-/883
39/-/35
42/-/37
44/-/39
42/-/37
44/-/39
46/42/38
195X1,160X680
195X1,400X680 195X1,590X680 235X1,590X690 195X1,400X680 195X1,590X680
38
35
27
32
32
35
14 to 25
Ivory white
Hermetically sealed swing type
Hermetically sealed scroll type
1.76
1.35
2.6
2.03
3.1
2.1
2.6
1.6
(Charged for 30 m)
2.7
(Charged for 30 m)
3.15
(Charged for 30 m)
48
44
595X845X300
43
49
50
45
990X940X320
78
21 to 46
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
97
2.7
3.7
(Charged for 30 m) (Charged for 30 m)
49
46
1,170X900X320
92
Indoor unit
Outdoor unit
Power supply
Cooling capacity1,2
Rated (Min. - Max.)
Outdoor unit
Cooling1
Power consumption
COP
Colour
Indoor
Airflow rate (H/L)
unit
Sound level (H/L)3
Dimensions (HXWXD)
Machine weight
Certified operation range
Outdoor
unit
Colour
Type
Compressor
Refrigerant charge
(R-410A)
Motor
output
Refrigerant charge (R-410A)
Sound level3
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified operation range
Piping
connections
Liquid (Flare)
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
Model
Name
50
kW
kW
W/W
140
125
140
FHQ60BVV1Gx2
FHQ71BVV1Bx2
RZR125LVVM
RZR140LVVM
RZR125LUY1
RZR140LUY1
5.32
2.50
2.4
White
17/14
600/494
39/35
195X1,160X680
27
14 to 25
Ivory white
Hermetically sealed scroll type
2.6
3.1
m3/min
cfm
dB(A)
mm
kg
°CWB
kW
3.15
(Charged for 30 m)
kg
dB(A)
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
4.55
2.75
5.32
2.50
unit
5.0
(2.3-5.6)
5.8
(2.6-6.3)
7.1
(3.2-8.0)
10.0
(5.0-11.2)
12.5
(5.7-14.0)
14.0
(6.2-15.4)
Cooling1
kW
W/W
1.39
3.60
1.63
3.56
2.22
3.20
2.82
3.55
3.73
3.35
----------
4.71
2.97
Cooling
m3/min
cfm
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
140
32/23
1,130/812
18/15
635/530
2.82
3.55
39/28
1,377/988
4.71
2.97
3.73
3.35
32/23
1,130/812
39/28
1,377/988
38/33
40/36
50-200 3
Pa
dB(A)
dB(A)
mm
kg
3 Phase, 380–415 V, 50 Hz
10.0
12.5
14.0
(5.0-11.2)
(5.7-14.0)
(6.2-15.4)
37/32
38/33
40/36
---------- 5
300X1,000X700
36
300X1,400X700
46
14 to 25
Ivory white
1.12
Hermetically sealed swing type
1.76
1.35
2.03
Hermetically sealed scroll type
2.9
1.8
2.4
2.4
2.9
1.6
(Charged for 30 m)
2.7
(Charged for 30 m)
3.15
(Charged for 30 m)
2.7
(Charged for 30 m)
3.7
(Charged for 30 m)
48
44
595X845X300
43
49
50
49
50
45
990X940X320
78
45
1,170X900X320
92
46
97
21 to 46
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
°CDB
mm
mm
mm
mm
m
m
46
97
125
140
125
140
FBQ60DV1x2
FBQ71DV1x2
FBQ60DV1x2
FBQ71DV1x2
Outdoor unit
RZR125LVVM
RZR140LVVM
RZR125LUY1
RZR140LUY1
46
Outdoor
unit
1 Phase, 220–240 V, 50 Hz
Indoor unit
Outdoor unit
Fan
Airflow rate
(H/L)
1 Phase, 220–240 V, 50 Hz
12.5
(5.7-14.0)
14.0
(6.2-15.4)
12.5
(5.7-14.0)
14.0
(6.2-15.4)
Cooling1
kW
W/W
3.73
3.35
4.71
2.97
3.73
3.35
4.71
2.97
Cooling
m3/min
cfm
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Piping
Liquid (Flare)
connections
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
---------18/15
635/530
50-200 3
Pa
Sound level4 Cooling (H/L)
dB(A)
Air filter
mm
Dimensions (HXWXD)
kg
Machine weight
Certified Operation range Cooling
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
Sound level4
3 Phase, 380–415 V, 50 Hz
kW
External static pressure
(Middle-High)
2.9
45
125
Indoor unit
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Colour
Indoor
1,170X900X320
97
21 to 46
o/ 9.5
o/ 15.9
VP20 (I.Do/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
1 Phase, 220–240 V, 50 Hz
1 Phase, 220–240 V, 50 Hz
Sound level4 Cooling (H/L)
dB(A)
Air filter
mm
Dimensions (HXWXD)
kg
Machine weight
Certified Operation range Cooling
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
Power supply
3.7
(Charged for 30 m)
46
Airflow rate
(H/L)
Model
Name
50
45
100
Twin Multi
3 Phase, 380–415 V, 50 Hz
12.5
13.3
(5.7-14.0)
(6.2-15.4)
4.55
2.75
140
kW
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Piping
Liquid (Flare)
connections
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
FHQ71BVV1Bx2
Cooling only
125
RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1
Sound level4
125
100
Outdoor unit
External static pressure
(Middle-High)
Outdoor
unit
71
FBQ50DV1V FBQ60DV1V FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1
Indoor unit
Outdoor unit
Fan
unit
60
Indoor unit
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Colour
Indoor
97
FHQ60BVV1Gx2
1 Phase, 220–240 V, 50 Hz
12.5
13.3
(5.7-14.0)
(6.2-15.4)
Power supply
45
Twin Multi
Model
Name
50
RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1
Outdoor unit
Cooling capacity1,2
Rated (Min. - Max.)
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Cooling only
dB(A)
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
37/32
---------- 5
300X1,000X700
36
14 to 25
Ivory white
Hermetically sealed scroll type
2.4
2.9
2.4
3.15
(Charged for 30 m)
50
45
2.9
3.7
(Charged for 30 m)
50
45
46
46
1,170X900X320
97
21 to 46
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Initial setting is standard.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.
33
34
SPECIFICATIONS
FLOOR STANDING TYPE
CEILING MOUNTED CASSETTE TYPE
Cooling only
50
Model
Name
Power supply
Outdoor
unit
100
125
140
100
125
Outdoor unit
RZR50LVVM RZR60LVVM RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1
1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz
kW
Airflow rate
(H/M/L)
Cooling1
kW
W/W
Cooling
m3/min
cfm
dB(A)
mm
kg
Sound level3 Cooling (H/M/L)
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
Sound level3
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Piping
Liquid (Flare)
connections
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
dB(A)
dB(A)
mm
kg
5.0
(2.3-5,6)
1.27
3.94
1.12
6.0
(2.6-6.3)
1.84
3.26
7.1
(3.2-8.0)
2.58
2.75
3 Phase, 380–415 V, 50 Hz
12.5
13.5
10.0
12.5
13.5
(5.7-14.0)
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
(6.2-15.4)
5.40
5.40
4.39
3.28
4.39
2.50
2.50
2.85
3.05
2.85
Fresh white
28/25/22
28/26/24
30/28/26
28/25/22
28/26/24
30/28/26
18/16/14
988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918
635/565/494
50/47/44
51/48/46
53/51/48
43/41/38
50/47/44
51/48/46
53/51/48
1,850X600X270
1,850X600X350
39
47
14 to 25
Ivory white
Hermetically sealed scroll type
Hermetically sealed swing type
3.1
2.3
2.8
3.4
1.35
1.76
2.03
2.4
10.0
(5.0-11.2)
3.28
3.05
2.7
(Charged for 30 m)
49
45
990X940X320
78
1.6
(Charged for 30 m)
48
44
595X845X300
43
°CDB
mm
mm
mm
mm
m
m
3.15
(Charged for 30 m)
50
46
97
2.7
(Charged for 30 m)
49
45
1,170X900X320
92
21 to 46
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
Indoor unit
Outdoor unit
Power supply
Outdoor unit
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Colour
Indoor
unit
Outdoor
unit
Fan
kW
Cooling1
Airflow rate
(H/M/L)
Cooling
kW
W/W
Sound
Cooling
Night quiet mode
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
Piping
Liquid (Flare)
connections
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
140
125
140
FVQ71CVEBx2
FVQ60CVEx2
FVQ71CVEBx2
dB(A)
dB(A)
mm
kg
°CDB
mm
mm
mm
mm
m
m
RZR125LUY1
1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz
12.5
13.5
(5.7-14.0)
(6.2-15.4)
5.40
4.39
2.50
2.85
RZR140LUY1
3 Phase, 380–415 V, 50 Hz
12.5
13.5
(5.7-14.0)
(6.2-15.4)
5.40
4.39
2.50
2.85
Fresh white
18/16/14
635/565/494
43/41/38
1,850X600X270
39
14 to 25
Ivory white
Hermetically sealed scroll type
3.1
2.8
m3/min
cfm
dB(A)
mm
kg
Sound level3 Cooling (H/M/L)
Dimensions (HXWXD)
Machine weight
Certified Operation range Cooling
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
level3
125
RZR140LVVM
2.4
3.15
(Charged for 30 m)
Cooling/Heating3
Night quiet mode
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
3.4
45
1,170X900X320
97
21 to 46
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50 (Equivalent length 70)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
46
1 Phase, 220–240 V, 50 Hz
5.0
5.8
(2.5-5.6)
(2.9-6.0)
140
100
125
140
7.1
(3.2-8.0)
1 Phase, 240 V, 50 Hz
10.0
12.5
(5.0-11.2)
(5.7-14.0)
13.6
(6.2-15.4)
3 Phase, 415 V, 50 Hz
13.6
10.0
12.5
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
16.0
(6.2-18.0)
11.2
(5.1-12.8)
kW
6.0
(3.5-7.0)
7.0
(3.5-8.0)
8.0
(3.5-9.0)
11.2
(5.1-12.8)
kW
kW
W/W
W/W
1.27
1.41
3.93
4.26
1.51
1.74
3.84
4.03
1.99
2.10
3.57
3.81
2.94
3.03
3.40
3.70
m3/min
cfm
dB(A)
mm
mm
kg
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
21/13.5
741/477
35/28
256X840X840
32/20
1,130/706
43/32
21
1.3
Hermetically sealed
swing type
1.6
2.75
(Charged for 30 m)
48/50
44
X
770 900X320
68
4.02
4.54
2.94
3.83
4.80
3.03
3.11
3.00
3.40
3.66
3.33
3.70
---------Fresh white
33/22.5
32/20
1,130/706
1,165/794
44/34
44/36
43/32
298X840X840
50X950X950
24
5.5
14 to 25
15 to 27
Ivory white
Outdoor unit
Sound level (H/L)3
Dimensions
Unit
(HXWXD)
Decoration panel
Machine
Unit
weight
Decoration panel
Cooling
Certified
Operation range Heating
Colour
Outdoor
Type
Compressor
unit
Motor output
Refrigerant charge (R-410A)
Sound level
Cooling/Heating3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
3.77
3.83
3.32
3.66
4.39
4.80
3.10
3.33
33/22.5
1,165/794
44/34
44/36
1.7
49/51
2.2
4.3
(Charged for 30 m)
50/52
45
X
X
1,345 900 320
108
2.9
46
Heat pump
25
35
50
60
FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
FFQ60BV1B
RXS25EBVMA
RXS35EBVMA
RXS50FVMA
RXS60FVMA
1 Phase, 220–240 V, 50 Hz
Outdoor unit
Cooling1
Power consumption
Heating2
Cooling
COP
Heating
Unit
Indoor
Colour
unit
Decoration panel
Airflow rate (H)
16.0
(6.2-18.0)
75
(Equivalent length 90)
30
Both liquid and gas piping
m
Indoor unit
14.0
(6.0-16.2)
Hermetically sealed scroll type
3.1
2.4
3.7
(Charged for 30 m)
49/51
50/52
45
46
X
X
1,170 900 320
98
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
1.9
1.7
50
(Equivalent length 70)
30
14.0
(6.0-16.2)
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
3.7
(Charged for 30 m)
46
Outdoor
unit
(H/L)3
Unit
Decoration panel
Unit
Machine
weight
Decoration panel
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Model
Name
50
45
kW
Cooling1
Heating2
Cooling
Heating
Colour
Unit
Decoration panel
Fan Airflow rate (H/L)
Sound level
Dimensions
(HXWXD)
125
RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
Power consumption
Indoor
unit
100
Outdoor unit
Outdoor unit
Heating capacity2
Rated (Min. - Max.)
COP
71
FCQ50LUV1V FCQ60LUV1V FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1
Sound level
FVQ60CVEx2
RZR125LVVM
Power supply
Cooling capacity1
Rated (Min. - Max.)
60
Indoor unit
Motor output
Refrigerant charge (R-410A)
Twin Multi
Model
Name
Model
Name
3.7
(Charged for 30 m)
50
46
97
Heat pump
50
140
FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Outdoor unit
Fan
71
Indoor unit
Cooling capacity1,2
Rated (Min. - Max.)
Power consumption
COP
Colour
Indoor
unit
60
kW
2.5
(1.2-3.0)
3.4
(1.2-3.7)
4.7
(1.7-5.6)
5.8
(1.7-6.0)
kW
3.2
(1.2-4.5)
4.0
(1.2-5.0)
5.5
(1.7-7.0)
7.0
(1.7-8.0)
kW
kW
W/W
W/W
0.73
0.92
3.42
3.48
1.10
1.20
3.09
3.33
1.62
1.88
2.90
2.93
2.07
2.49
2.80
2.81
12/8
424/282
36/27
15/10
530/353
41/32
---------White
m3/min
cfm
dB(A)
mm
mm
kg
kg
°CWB
°CDB
kW
kg
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
9/6.5
318/229
29.5/24.5
10/6.5
353/229
32/25
286X575X575
55X700X700
17.5
2.7
14 to 23
10 to 30
Ivory white
Hermetically sealed swing type
1.1
1.5 (Charged for 10 m)
0.6
1.0 (Charged for 10 m)
46/47
47/48
49/49
735X825X300
48
550X765X285
34
10 to 46
-15 to 20
-15 to 18
o/ 6.4
o/ 12.7
o/ 9.5
VP20 (I.D o/ 20XO.D o/ 26)
o/ 18.0 (Hole)
30
20
20
15
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
35
36
SPECIFICATIONS
CEILING SUSPENDED TYPE
CEILING MOUNTED SLIM DUCT TYPE
Heat pump
Indoor unit
Model
Name
Outdoor unit
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
Outdoor
unit
FHQ35BVV1B
RXS35EBVMA
kW
kW
Colour
Airflow rate (H/L)
Sound level (H/L)3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound level
Cooling/Heating3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
1 Phase, 220–240 V, 50 Hz
3.4
(1.2-3.7)
4.0
(1.2-5.0)
Outdoor unit
Cooling1
Heating2
Cooling
Heating
Model
Name
kW
kW
W/W
W/W
1.05 (0.3-1.23)
1.11 (0.29-1.61)
3.24 (4.00-3.01)
3.60 (4.14-3.11)
White
13/10
459/353
37/32
195X960X680
24
14 to 23
10 to 30
Ivory white
Hermetically sealed swing type
0.6
1.0
(Charged for 10 m)
47/48
550X765X285
34
10 to 46
-15 to 20
o/ 6.4
o/ 9.5
VP20 (I.D o/ 20XO.D o/ 26)
o/ 18.0 (Hole)
20
15
Both liquid and gas piping
m3/min
cfm
dB(A)
mm
kg
°CWB
°CDB
kW
kg
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
COP
Indoor
unit
Heat pump
25
35
50
60
Indoor unit
FDXS25CVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
Outdoor unit
RXS25EBVMA
RXS35EBVMA
RXS50FAVMA
RXS60FVMA
35
Outdoor unit
1 Phase, 220–240 V, 50 Hz
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Airflow rate (H/M/L/SL)
Fan
External static pressure
Sound level (H/M/L/SL)3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Outdoor
Type
Compressor
unit
Motor output
Refrigerant charge (R-410A)
3
Cooling (H/L)
Sound level
Heating (H/L)
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
W/W
W/W
2.4
(1.2-3.0)
3.2
(1.2-4.5)
0.69 (0.3-0.92)
0.91 (0.29-1.49)
3.48 (4.00-3.26)
3.52 (4.14-3.02)
3.4
(1.2-3.8)
4.0
(1.2-5.0)
1.09 (0.3-1.27)
1.18 (0.29-1.79)
3.12 (4.00-2.99)
3.39 (4.14-2.79)
9.5/8.8/8.0/6.7
335/311/282/237
10.0/9.3/8.5/7.0
353/328/300/247
5.0
(1.7-5.3)
5.8
(1.7-6.0)
1.65 (0.44-1.93)
1.92 (0.4-2.04)
3.03 (3.86-2.75)
3.02 (4.25-2.94)
6.0
(1.7-6.5)
7.0
(1.7-8.0)
2.13 (0.44-2.49)
2.32 (0.4-3.18)
2.82 (3.86-2.61)
3.02 (4.25-2.52)
12.0/11.0/10.0/8.4
424/388/353/297
16.0/14.8/13.5/11.2
565/523/477/395
37/35/33/31
38/36/34/32
200X1,100X620
30
---------m3/min
cfm
Pa(mmH2O)
dB(A)
mm
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
40
35/33/31/29
200X900X620
25
27
14 to 23
10 to 30
Ivory white
Hermetically sealed swing type
0.6
1.0 (Charged for 10 m)
1.1
1.5 (Charged for 10 m)
47/44
48/45
49/46
49/46
550X765X285
34
735X825X300
48
10 to 46
-15 to 18
-15 to 20
o/ 6.4
o/ 9.5
o/ 12.7
VP20 (I.D o/ 20XO.Do/ 26)
o/ 18.0 (Hole)
20
15
30
20
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal).
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
CEILING SUSPENDED TYPE
50
Model
Name
Power supply
Cooling capacity1
Rated (Min. - Max.)
COP
71
100
125
140
100
125
Outdoor unit
RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
Outdoor unit
1 Phase, 220-240 V, 50 Hz
5.0
5.8
(2.5-5.6)
(2.9-6.0)
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Fan Airflow rate (H/M/L)
Outdoor
unit
Sound level (H/M/L)3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Cooling/Heating3
Night quiet mode
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
W/W
W/W
6.0
(3.5-7.0)
7.0
(3.5-8.0)
1.39
1.67
3.60
3.60
m3/min
cfm
dB(A)
mm
kg
°CWB
°CDB
1.63
2.05
3.56
3.42
5.8
(3.2-8.0)
1 Phase, 240 V, 50 Hz
9.2
11.2
(5.0-11.2)
(5.7-14.0)
13.2
(6.2-15.4)
3 Phase, 415 V, 50 Hz
13.2
9.2
11.2
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
7.5
(3.5-9.0)
10.5
(5.1-12.8)
16.0
(6.2-18.0)
10.5
(5.1-12.8)
1.77
2.32
3.28
3.23
White
17/-/14
600/-/494
39/-/35
195X1,160X680
27
2.93
3.33
3.14
3.15
kg
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
1.3
1.6
2.75
(Charged for 30 m)
3.70
4.35
3.03
3.10
1.7
1.9
2.4
3.7
(Charged for 30 m)
3.1
49/51
50/52
45
46
1,170X900X320
98
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50
(equivalent length 70)
2.3
49/51
2.7
4.3
(Charged for 30 m)
50/52
45
1,345X900X320
108
75
(equivalent length 90)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
37
16.0
(6.2-18.0)
Hermetically sealed scroll type
48/50
44
770X900X320
68
30
13.5
(6.0-16.2)
4.40
2.85
3.55
4.33
5.00
3.26
4.35
4.93
3.00
3.23
3.15
3.04
3.20
3.22
3.10
3.24
Fresh white
White
Fresh white
34/29/24
24/-/20
30/-/25
34/29/24
24/-/20
30/-/25
847/-/706
1,059/-/883 1,200/1,024/847
847/-/706
1,059/-/883 1,200/1,024/847
46/42/38
42/-/37
44/-/39
46/42/38
42/-/37
44/-/39
195X1,400X680 195X1,590X680 235X1,590X690 195X1,400X680 195X1,590X680 235X1,590X690
38
38
32
35
32
35
14 to 25
15 to 27
Ivory white
Hermetically sealed
swing type
kW
13.5
(6.0-16.2)
50
60
71
FBQ60BV1A
FBQ71BV1A
RXS50FAVMA
RXS60FVMA
RXS71FVMA
kW
kW
W/W
W/W
5.0
(1.7-5.6)
6.0
(1.7-7.0)
1.98 (0.44-2.25)
1.93 (0.4-2.52)
2.53 (3.86-2.49)
3.11 (4.25-2.78)
1 Phase, 220–240 V, 50 Hz
5.7
(1.7-7.0)
7.0
(1.7-8.0)
2.23 (0.44-2.83)
2.26 (0.4-2.94)
2.56 (3.86-2.47)
3.10 (4.25-2.72)
----------
6.7
(2.3-8.0)
8.2
(2.3-10.0)
2.57 (0.57-3.26)
2.67 (0.45-3.85)
2.61 (4.04-2.45)
3.07 (5.11-2.60)
m3/min
cfm
m3/min
cfm
13/9
459/318
14/10
494/353
2.9
46
Indoor unit
Model
Name
Outdoor unit
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
Heat pump
FBQ50BV1A
140
FHQ50BVV1V FHQ60BVV1V FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA
Indoor
unit
Sound level
60
Indoor unit
Heating capacity2
Rated (Min. - Max.)
Power consumption
CEILING MOUNTED BUILT-IN TYPE
Heat pump
Outdoor unit
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Fan
Air flow rate Cooling
(H/L)
Heating
External static pressure3
Pa
(High-Standard-Low)
Sound level (H/L)4
dB(A)
mm
Dimensions (HXWXD)
kg
Machine weight
Cooling
CWB
Certified
Operation range
Heating
CDB
Colour
Outdoor
Type
Compressor
unit
Motor output
kW
kg
Refrigerant charge (R-410A)
dB(A)
Sound level4 Cooling/Heating
mm
Dimensions (HXWXD)
kg
Machine weight
Cooling
CDB
Certified
Operation range
Heating
CWB
mm
Piping
Liquid
connections
mm
Gas
Indoor unit
mm
Drain
Outdoor unit
mm
m
Max. interunit piping length
m
Max. installation level difference
Heat insulation
18/13
636/459
19/14
671/494
88-49-20
33/29
300X700X800
34
34/30
300X1000X800
41
14 to 23
10 to 30
Ivory white
Hermetically sealed swing type
1.1
1.5 (Charged for 10 m)
49/49
47/48
735X825X300
48
1.92
2.3 (Charged for 10 m)
52/52
770X900X320
71
10 to 46
-15 to 18
o/ 6.4
o/ 15.9
o/ 12.7
VP25 (I.D o/ 25XO.D o/ 32)
o/ 18.0
30
20
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Initial setting is standard.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
38
SPECIFICATIONS
OPTIONS
Indoor unit
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
50
Model
Name
Cooling capacity1,3
Rated (Min. - Max.)
Heating capacity2,3
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
71
100
CEILING MOUNTED CASSETTE TYPE
Heat pump
125
140
100
125
Kit name
140
Indoor unit
FBQ50DV1V FBQ60DV1V FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1
Name of option
Outdoor unit
RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Fresh air
Chamber
type
intake kit1
Indoor unit
Outdoor unit
Power supply
60
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Fan Airflow rate (H/L)
External static pressure
(Middle-High)
Sound level (H/L)5
Air filter
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Outdoor
Colour
unit
Type
Compressor
Motor output
Refrigerant charge
(R-410A)
Cooling/Heating5
Sound level
Night quiet mode
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
W/W
W/W
1 Phase, 220-240 V, 50 Hz
5.0
5.8
(2.5-5.6)
(2.9-6.0)
6.0
7.0
(3.5-7.0)
(3.5-8.0)
1.35
1.59
1.38
1.76
3.70
3.65
3.98
4.35
m3/min
cfm
7.1
(3.2-8.0)
8.0
(3.5-9.0)
2.22
2.43
3.20
3.29
18/15
635/530
1 Phase, 220-240 V, 50 Hz
1 Phase, 240 V, 50 Hz
13.1
10.0
12.5
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
16.0
11.2
14.0
(6.2-18.0)
(5.1-12.8)
(6.0-16.2)
3.17
3.97
4.16
3.15
3.95
4.68
3.15
3.56
37/32
mm
kg
°CWB
°CDB
300X1,000X700
36
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
3.42
39/28
1,377/988
3.56
3.54
3.42
32/23
1,130/812
39/28
1,377/988
38/33
40/36
50-200 4
dB(A)
kg
3.54
----------
32/23
1,130/812
Pa
kW
3 Phase, 415 V, 50 Hz
13.1
12.5
10.0
(6.2-15.4)
(5.7-14.0)
(5.0-11.2)
16.0
11.2
14.0
(6.2-18.0)
(5.1-12.8)
(6.0-16.2)
3.17
3.97
4.16
3.15
3.95
4.68
38/33
40/36
---------- 6
300X1,400X700
46
14 to 25
15 to 27
Ivory white
Hermetically sealed swing type
1.7
1.3
1.6
2.75
(Charged for 30 m)
48/50
44
770X900X320
68
m
50
(Equivalent length 70)
30
m
Hermetically sealed scroll type
2.9
2.4
1.9
2.4
3.7
4.3
(Charged for 30 m)
(Charged for 30 m)
49/51
50/52
49/51
50/52
45
46
45
1,345X900X320
1,170X900X320
98
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
75
(Equivalent length 90)
30
Both liquid and gas piping
1.9
2.9
46
Remark
FCQ50LUV1V
FCQ60LUV1V
FCQ60LUV1
FCQ71LUV1
FCQ100LUV1 FCQ125LUV1 FCQ140LUV1
BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KDDP55B160
KDDP55B160K
KDDP55X160
KKSJ55KA160
Without T-joint pipe and fan
With T-joint pipe, without fan
Direct installation type
2
Chamber connection kit
Insulation kit for high humidity
(Colorimetric method 65%)
High-efficiency filter
(including chamber)
(Colorimetric method 90%)
Replacement
(Colorimetric method 65%)
high-efficiency filter
(Colorimetric method 90%)
Filter chamber
Replacement long-life filter
Ultra long-life filter
Replacement ultra long-life filter
Branch duct chamber
Cooling only
Wireless type
Remote controller
Heat pump
Wired type3
Navigation Remote Controller
Wired type3
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Touch Controller4
Adaptor for wiring5
Wiring adaptor for electrical appendices5
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
KDTP55K160
KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160
KDTP55K80
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDJP55B80
KDJP55B160
BRC7F633F
BRC7F632F
BRC1C61
BRC1E62
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1C63
KRP4AA53
KRP1H98
KRCS01-4B
Note: 1Refer to page 12 for the details.
2
Required for installing high-efficiency filter or ultra long-life filter.
3
Wiring for wired remote controller to be procured locally.
4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
5
Installation box for adaptor PCB (KRP1H98) is necessary.
Round flow type: List of optional parts required to achieve different flow patterns
Note :
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
4
Initial setting is standard.
5
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
6
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.
1
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
2
All round flow 4-way flow
FLOOR STANDING TYPE
Heat pump
50
Model
Name
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
COP
Indoor
unit
Outdoor
unit
Optional accessory parts
60
71
100
125
140
100
125
Indoor unit
FVQ50CVE
Outdoor unit
RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Outdoor unit
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Fan Airflow rate (H/M/L)
Sound level (H/M/L)3
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Cooling/Heating3
Night quiet mode
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Sound level
Max. installation level difference
Heat insulation
kW
kW
W/W
W/W
m3/min
cfm
dB(A)
mm
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
1 Phase, 240 V, 50 Hz
7.1
10.0
(3.2-8.0)
(5.0-11.2)
8.0
11.2
(3.5-9.0)
(5.1-12.8)
2.33
3.28
2.61
3.67
3.05
3.07
3.05
3 Phase, 415 V, 50 Hz
12.5
10.0
13.5
(5.7-14.0)
(5.0-11.2)
(6.2-15.4)
14.0
11.2
16.0
(6.0-16.2)
(5.1-12.8)
(6.2-18.0)
3.28
4.39
5.40
3.67
4.26
5.28
3.05
2.85
2.50
3.05
3.29
3.03
12.5
13.5
(5.7-14.0)
(6.2-15.4)
14.0
16.0
(6.0-16.2)
(6.2-18.0)
4.39
5.40
4.26
5.28
2.85
2.50
3.29
3.03
Fresh white
18/16/14
28/25/22
28/26/24
30/28/26
28/25/22
28/26/24
30/28/26
635/565/494
988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918
50/47/44
51/48/46
53/51/48
43/41/38
50/47/44
51/48/46
53/51/48
1,850X600X270
1,850X600X350
39
47
14 to 25
15 to 27
Ivory white
Hermetically sealed swing type
Hermetically sealed scroll type
1.3
1.6
1.7
2.4
3.1
1.7
2.2
2.9
1.9
2.75
3.7
4.3
(Charged for 30 m)
(Charged for 30 m)
(Charged for 30 m)
48/50
49/51
50/52
49/51
50/52
44
45
46
45
46
770X900X320
1,345X900X320
1,170X900X320
68
98
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
50
75
30
(Equivalent length 70)
(Equivalent length 90)
30
Both liquid and gas piping
5.0
(3.2-5.6)
6.0
(3.5-7.0)
1.27
1.52
3.94
3.94
Independently installable optional parts
140
5.8
(3.2-6.0)
7.0
(3.5-8.0)
1.78
2.15
3.26
3.26
Panel/grille related
Panel spacer
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
Panel spacer1
High-efficiency filter2
Ultra-long-life filter2
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
1
o
o
o
x
o
o
o
o
o
o
o
o
o
x
x
o
o
o
o
x
o
o
o
High-humidity
operation kit
High-efficiency
filter2
Ultra-long-life
filter2
x
o
x
o
o
o
o
o
x
o
o
o
o
x
x
x
x
x
High-humidity
operation kit
High-efficiency
filter2
x
o
x
o
x
x
x
x
x
x
x
High-humidity
operation kit
High-efficiency
filter2
Ultra-long-life
filter2
x
x
x
x
x
x
o
o
o
3-way flow 2-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
Ultra-long-life filter2
Panel spacer1
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o3
o3
o3
o3
x
o3
o
o
o
o
o3
o
x
x
o
o3
o
x
o
o
Ultra-long-life
filter2
o3
o
o
o
x
Branch duct connection
Optional accessory parts
Independently installable optional parts
duct1
Branch
(Chamber type)
(Round duct type)
1-way branch / unit 3-way flow
2-way branch / unit 2-way flow
1-way branch / unit 2-way flow
Panel spacer1
o
x
x
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o
o
o
4
4
4
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
39
40
OPTIONS
Indoor unit
Indoor unit
CEILING MOUNTED BUILT-IN TYPE
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Name of option
Decoration panel
Remote controller
Kit name
Remark
Wireless type
FFQ50BV1B
FFQ35BV1B
BYFQ60B8W1/BYFQ60B3W1
BRC7E531W
BRC7E530W
BRC1C61
BRC1E62
KRP1BA57
KRP4AA53
KRCS01-1B
KRP1BA101
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
DTA112BA51
KAFQ441BA60
KDDQ44XA60
KDBH44BA60
KDBQ44BA60A
FFQ25BV1B
Cooling only
Heat pump
Wired type1
Wired type1
Navigation Remote Controller
Adaptor for wiring2
Wiring adaptor for electrical appendices2
Remote sensor (for indoor temperature)
Installation box for adaptor PCB
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Touch Controller3
Interface adaptor for SkyAir series
Replacement long-life filter
Fresh air intake kit
Direct installation type
Sealing material of air discharge outlet
Panel spacer
FFQ60BV1B
Name of option
Remark
Service panel
Air discharge adaptor
Remote controller
Wireless type
Wired type1
Navigation Remote Controller
Wired type1
Adaptor for wiring (interlock for fresh air intake fan)
Wiring adaptor for electrical appendices
Interface adaptor for SkyAir series
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Touch Controller2
Kit name
FBQ60BV1A
FBQ50BV1A
KTB25KA56W
KDAJ25K56A
FBQ71BV1A
KTB25KA80W
KDAJ25K71A
Heat pump
BRC4C62
BRC1C61
BRC1E62
KRP1BA54
KRP4AA51
DTA112BA51
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
Note: 1Wiring for wired remote controller to be procured locally.
2
This optional accessory requires DTA112BA51.
Note: 1Wiring for wired remote controller to be procured locally.
2
Installation box for adaptor PCB (KRP1BA101) is necessary.
3
This optional accessory requires DTA112BA51.
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Kit name
Name of option
CEILING SUSPENDED TYPE
Name of option
High-efficiency filter1
Remark
Resin net
Replacement long-life filter
Fresh air intake kit
Drain pump kit
L-type piping kit (for upward direction)
Remote controller
Wireless type
FHQ35BVV1B FHQ50BVV1V
KAF501DA56
KDU50N60VE
KHFP5MA35
Cooling only
Heat pump
Wired type1
Wired type1
Navigation Remote Controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Touch Controller
Adaptor for wiring
Wiring adaptor for electrical appendices4
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
----------------------------
Kit name
FHQ60BVV1V
FHQ140CAVEB
FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B
FHQ60BVV1G
FHQ140CAVEA
KAF501DA80
KAF501DA112 KAF501DA160 KAFP501A160
---------KDDQ50A140
KDU50N125VE
KDU50P140VE
KHFP5MA160
KHFP5N160
BRC7EA66
BRC7GA56
BRC7EA63A
BRC7GA53
BRC1C61
BRC1E62
DCS302CA613
DCS302CA612
DCS301BA612
DCS301BA613
DST301BA612
DST301BA613
DCS601C513
DCS601C512
KRP1BA54
KRP4AA52
---------DTA112BA51
KRP1D93A
KRP1CA93
KRCS01-4B
KRCS01-1B
KJB311AA
KJB212AA
Note: 1Wiring for wired remote controller to be procured locally.
2
This optional accessory requires DTA112BA51.
3
FHQ140CA is equipped standardly with the interface adaptor for SkyAir series. DTA112BA51 is unnecessary.
4
Installation box for adaptor PCB is necessary.
CEILING MOUNTED SLIM DUCT TYPE
Name of option
Remark
65%
90%
Filter chamber
Replacement long life filter
Replacement long life filter chamber kit
Service panel
Air discharge adaptor
Remote controller
Wireless type
FBQ60DV1V
FBQ50DV1V
FBQ60DV1
KAF372AA80
KAF373AA80
KDDF37AA80
KAF371AA80
KAF375AA80
KTB25KA80W
KTBJ25K80F
KTBJ25K80T
KDAJ25K71A
Cooling only
Heat pump
FBQ71DV1
FBQ100DV1
FBQ125DV1
FBQ140DV1
KAF372AA160
KAF373AA160
KDDF37AA160
KAF371AA160
KAF375AA160
KTB25KA160W
KTBJ25K160F
KTBJ25K160T
KDAJ25K140A
BRC4C64
BRC4C62
BRC1C61
BRC1E62
KRP1C64
KRP4AA51
KRCS01-4B
KRP4A96 5,6
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
Wired type2
Navigation Remote Controller
Wired type2
Adaptor for wiring (interlock for fresh air intake fan)
Wiring adaptor for electrical appendices
Remote sensor
Mounting plate for adaptor PCB.4
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Touch Controller3
Note: 1If installing a high efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required.
2
Wiring for wired remote controller to be procured locally.
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
4
Mounting plate for adaptor PCB is necessary for each adaptor marked .
5
Up to 2 adaptors can be fixed for each mounting plate.
6
Only one mounting plate can be installed for each indoor unit.
FLOOR STANDING TYPE
Kit name
FDXS25CVMA
FDXS35CVMA
controller1
Wired remote
Wired remote controller code
Remark
FDXS60CVMA
KDT25N50
Name of option
Replacement long-life filter
Remote controller
Navigation Remote Controller
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Touch Controller2
Adaptor for wiring3
Wiring adaptor for electrical appendices
Installation box for adaptor PCB
BRC944B2
BRCW901A03
BRCW901A08
KRC72A
KRP413AB1S
KKF917A4
KRP928BB2S
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KDGF19A45
Length 3 m (shielded wire)
Length 8 m (shielded wire)
5-room centralised controller2
Adaptor PCB (normal open/normal open pulse contact)3
The remote controller loss prevention with the chain
Interface adaptor for DIII-NET use
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Touch Controller4
Suction grille
Insulation kit for high humidity
FDXS50CVMA
KDT25N63
Remark
FVQ50CVE
Wired type1
Wired type1
FVQ60CVE
Kit name
FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
KAFJ95L160
BRC1C61
BRC1E62
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1BA57
KRP4AA52
KRP4AA95
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA95) is necessary.
Note: 13 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary .
2
Adaptor PCB (KRP413AB1S) is also required for each indoor unit.
3
Time clock and other devices should be obtained locally.
4
This optional accessory requires KRP928BB2S.
41
42
OPTIONS
DIMENSIONS
Outdoor unit
CEILING MOUNTED CASSETTE TYPE
Kit name
Cooling only
Remark
RXS25EBVMA
Air direction adjustment grille
Drain plug
RXS35EBVMA
KPW937A4
One set includes 5 pieces for 5 units
RXS71FVMA
167
160
67
950
29
95
93
160
124
95
110
B arrow view
[FCQ50-71LU]
Connection position
of branch duct
(square-shaped type)
[FCQ100-140LU]
157
350
A
4
1
2
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
55
27-M4 Prepared hole
5
95
167
93
29
60
42
105
160
298
125
165
157
3
840
81 2x100=200 85
160
64
50
130
Connection position
of branch duct
(square-shaped type)
20 C/L
280
330
157
350
213
C/L
80
90
183
ø10
(kn 0
ock
hole
)
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
C arrow view
Required space
200mm or more
55
150
340
80 2x100=200 80
160
350
67
95
29
90
196
ø10
(kn 0
ock
hole
)
C arrow view
[FCQ100-140LU]
55
840
2x100=200 80
25
160
2x100=200
25
213
80
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
160
90
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
C/L
90
130
256
157
350
124
20-M4 Prepared hole
5
95
110
124
60
55
42
105
2
280
330
840
81 2x100=200 85
64
124
50
1500 or more
(required space) 160
From the floor side 2500 or more
For height installation
1
150
125
165
256
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
157
4
55
3
167
93
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
80
[FCQ50-71LU]
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
160
124
109
95
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
256
157
350
A
1500mm or more
1500mm
or more
1500mm
or more
200mm
or more
1500mm or more
The necessary space is 500mm or more when the
air-outlet is blocked with the accessory.
Moreover when the corner areas are blocked
(both right and left of the blocked air outlet),
the necessary space is 200mm or more.
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
KPW945A4
KKP937A4
KKP945A4
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
43
16-M4 Hole
157
350
Connection position
of branch duct
(square-shaped type)
7
16-M4 Prepared hole
50
40
RXS60FVMA
B arrow view
6
[FCQ100-140LU]
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
Connection position
85 of branch duct
(round shape type)
2x100=200
160
C/L
Drain Connection
Side
95
110
124
850
Adjustable(0~675)
350
55
16-M4 Hole
157
350
1500 or more 67
(required space) 160
From the floor side 2500 or more
For height installation
Name of option
840
340
80 2x100=200 80
124
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
Kit name
Heat pump
RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A
RZQ71KCV4A
RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
Kit name
Heat pump
RXS50FVMA
RXS50FAVMA
C
81
A arrow view
20 C/L
160
288
10
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
8
Pipe Connection
Side
[FCQ50-71LU]
55
Note 2
[FCQ100-140LU]
Connection position
85 of branch duct
(round shape type)
2x100=200
124
C/L
81
420
KHRP58P216T
RZQ60KBV1V
RZQ60KBV4A
[FCQ50-71LU]
950
780(Hanging bolt pitch)
9
860~910(Ceiling opening space) (Note 4)
710(Hanging bolt pitch)
420
RZR140LUY1
Kit name
Cooling only
RKS25AVMG
RKS35AVMG
RKS50AVMG
RKS60AVMG
KPW937A4
KPW945A4
KKP937A4
RZQ50KBV1V
RZQ50KBV4A
300
or less
95
167
Name of option
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
KHRP58P216T
860~910(Ceiling opening space) (Note 4)
KKPJ5G280
---------KKTP5B112
850
Adjustable(0~675)
One set includes 5 pieces for 5 units
[FCQ50-140LU]
B
----------
Remark
[FCQ50-140LU]
RZR140LVVM
175
RZR100LUY1
Name of option
RZR125LVVM
Kit name
Cooling only
RZR125LUY1
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
Name of option
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
Refrigerant branch piping kit
For twin multi
RZR100LVVM
175
29
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
Refrigerant branch piping kit
For twin multi
RZR60LUV1V
RZR71LVVM
RZR60LVVM
KKP014A4
-------------------------------------
160
246
10
RZR50LUV1V
RZR50LVVM
50
40
Name of option
Air direction adjustment grille
Drain plug
(Unit: mm)
1
2
3
4
5
6
7
8
9
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Transmission wiring connection
Remote controller wiring
connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
44
DIMENSIONS
(Unit: mm)
CEILING SUSPENDED TYPE
1500mm or more*
575
62.5
1500mm or more*
295 or more
196
4
A
*When the discharge grill is closeout, the
required space is 200mm or more.
57 13
30 or more
(Service space)
1590
Obstacle
Floor side
6
76
3 Drain pipe connection
4 Power supply connection
5 Remote control code and
control wiring connection
6 Air discharge grille
7 Suction grille
8 Drain hose
CEILING SUSPENDED TYPE
225
275
300
275
6
80
3
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
(Applies to FHQ35-71BV only)
The remote control code is the standard <about 3 m outside the machine> attached.
(0.5 mm2 2 wicks O.D. 5.4)
(It is not attached to VRV.)
2
7
5
80
105
170
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
900
240 or more
20 or more
20 or more
5
(Required space)
300
1
130 63
20-M5 Holes
(All around)
Air discharge grille
Air suction grille
Air filter
Gas pipe connection
Liquid pipe connection
Drain pipe connection
Earth terminal (inside the electric components box)(M4)
Suspension bracket
Backward pipe and wiring connection opening lid
Upward pipe and wiring connection opening lid
Right side pipe connection
Left back drain pipe connection
Left side drain pipe connection
Right side drain pipe connection
Hole of wall for taking out in piping back
Upward drain pipe connection
Upward gas pipe connection
Upward liquid pipe connection
170
100
30
18-M4 Holes
(All around)
10
100
160
180
90
50
20
10
2
860
4xP150=600
Liquid pipe connection
Gas pipe connection
Socket for drain
Drain hose (Standard accessory)
Control box
Infrared receiver unit connection
Power supply connection
Suspension bracket
Air filter (Standard accessory)
Protection net
Allow view A
880
90
1
2
3
4
5
6
7
8
9
10
Inspection door
(ceiling opening)
90
57.5
80
Ceiling
14
Brand name plate
(Note.2)
The Front
Obstacle
Floor side
4 o/ 45
55
21
30 or more
(Service space)
12.5
B
30 or more
(Service space)
Suspension bolt
4-M8~M10
153
6
80
11
90
155
55
300 or more
13
(Required space)
195
5
(All around)
22-o/ 4.7 Hple
8xP100=800
940
(Suspension bolt pitch)
8
Position : Hole of wall for taking out in piping back
(View from the front)
400 or more
(In case of
bottom suction)
A
《Service space》
47
1
40
5
(Required space)
For height installation
From the floor side 2500 or more 155
Hanging bolt
4-M8~M10
Drain pipe connection VP20
(For left piping)
45
15
500
(Suspension bolt pitch)
105
8
A
(Hanging position)
680
4
620
60
10
620
127
200
170
1550 1590
65
60
Position slit hole for taking out in piping back
(View from the front)
330
3
4
5
7
150
100
90
80
7xP100=700
780
800
820
《In case of back-suction》
9
20-M5 Holes
(All around)
10
200
180
160
100
FHQ125BVV1B
50
10
20
50
1360 1400
83
105
156
300 or more
(Service space)
900
115 60
1120 1160
FHQ100BVV1B
5
[FDXS25-50CVMA]
65
FHQ71BVV1B
7
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
5
135 (Required space)
1120 1160
2
Position : Hole of wall for taking out in piping back
(View from the front)
145 60
135
1120 1160
FHQ60BVV1G
40
FHQ60BVV1V
9
12
85
102
160
185
192 36
1120 1160
210
FHQ50BVV1V
260
B
960
170
105
90
18 17 16 142 58
(Hanging
position)
A
920
3
14
CEILING MOUNTED SLIM DUCT TYPE
[FHQ35-125BV]
FHQ35BVV1B
220
103
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection
5 Liquid pipe connection
6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear piping penetration cover
10 Top panel penetration cover
11 Right side pipe connection
12 Left back drain pipe connection
13 Left side drain pipe connection
14 Right side drain pipe connection
15 Hole of wall for taking out in piping back
16 Upward drain pipe connection
17 Upward gas pipe connection
18 Upward liquid pipe connection
19 Power supply wiring and a unit wiring back connection
20 Power supply wiring and a unit wiring upper connection
Brand name plate
(Note.2)
1 Liquid pipe connection
2 Gas pipe connection
57
6
o/ 45
The Front
Drain pipe connection VP20
(For left piping)
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit : on the bell mouth inside suction grille
manufacture's label for decoration panel : on the inner frame inside suction grille
2
In case of using wireless remote controller, this position will be a signal receiver.
refer to the drawing of wireless remote controller in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45mm or less between
the main unit and the ceiling opening so that the panel overlap allowance can be ensured.
11
5
30 or more
(Service space)
268
2
From the floor side
2500 or more
45 or less
Note)4.
45 or less
1
1500 or more
(Required space)
Hanging bolt
4–M8 to M10
(180)
145
183
285
205
172
211
55
30
260
25
5
4
1
19 15
23
62.5
Hanging bolt
4-M8~M10
175
62.5
Position slit hole for taking out in piping back
(View from the front)
1550
214
221
268
575
For height installation
62.5
63
134 59
91
131
197
1500mm or more*
3
12
(Hanging bolt pitch)
690
For height installation
750
Adjustable(0–545)
Required space
1500mm or more*
51 60
10
157 63
210
260
320
116
235
B arrow view
7
A arrow view
9
8
300 or more
(Required space)
Outdoor air intake
(Direct connection)
4–M4 Hole
(Hanging
bolt pitch)
89
100
5
(Required space)
Piping connection
side
Ceiling
B
150
533 (Hanging bolt pitch)
700
6
585–660 (Ceiling opening space)
210
Drain connection
side
Connection position of fresh air intake kit
φ100(Knock out hole)
120
90
115
18 17 20 16
89
8
90
Note)2.
From the floor side 2500 or more 197
700
210
156
105
102
131 57
40
300 or less
175
92
[FHQ140CAVEB(A)]
585–660 (Ceiling opening space)
533 (Hanging bolt pitch)
320
30
87
100
163
189
195 35
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
9
6
7xP100=700
780
800
820
130
100
90
80
Notes:
1
In case of back-suction, mount chamber cover to bottom side of the unit.
In case of bottom-suction, mount chamber cover to back side of the unit.
2
Location of unit's Name Plate: control box cover.
3
Mount the air filter at the suction side.
(Select its colorimethod (Gravity method) 50 % or more)
It can not be equipped with air filter (accessory) when connecting duct to suction side.
4
Pipe specification
FDXS25
FDXS35
《In case of bottom-suction》
FDXS50
o/ 9.5 (Flare connection)
o/ 12.7 (Flare connection)
46
DIMENSIONS
(Unit: mm)
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
CEILING MOUNTED SLIM DUCT TYPE
[FBQ50/60DV1V, 60/71DV1]
300
CASE 1)
200
180
160
100
《In case of bottom-suction》
700
20
or more
200
or less
1000 200
or more or less
165
80
925
5
6
7
8
9
10
11
12
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Earth terminal
(Terminal in Control box)
Control box(Inside)
Remote control wiring
connection
Power supply wiring and a
transmission wiring
Air discharge flange
Air suction flange
Hanger
Socket (for maintenance)
Drain hose(Accessory)
A
B
C
FBQ50BV1A
556
533
4X120=480
FBQ60/71BV1A
856
833
D
A
E
700 460
6X120=720 1000 760
F
G
3X150=450
5X150=750
485
785
1
2
3
4
5
6
7
8
9
10
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Interunit wiring port
Power wiring port
Drain hole
Discharge flange
suction flange
Switch box
Inspection hole
H
I
J
6X65=390 7X65=455 750
11X65=715 12X65=780 1050
Air outlet
2 6
Air inlet
(Note.2)
5
169
11
290
28 7 4
700
Ceiling
Control box
49
300 12
View
(From the Air outlet)
713
or less
20-8X12 oblong hole
(All around)
Floor surface
B
Inspection
Ceiling
hatch
700
700
Inspection hatch 2
or more
or more
(SAME AS THE
View B-1 View B-2
INDOOR UNIT
SIZE OR MORE)
8X150=1200
1325
1350
(From the Air inlet)
Notes:
1
Location of MANUFACTURE'S LABEL: Control box surface
2
Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more.
3
Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.
4
Space for Service Works
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)
2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)
3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
200
or less
200
or less
165
167 3 1
CASE 2),3)
Inspection hatch 1
(450mmX450mm)
Control box
Inspection hatch 3
(SAME AS THE
INDOOR UNIT
SIZE +300 OR
MORE)
Control box
1700
or more
19X65=1235
1400
7X150=1050
700 or more
(Service space)
300
195
46
Inspection hatch 450 or more
3X65=195
45
4
65
450 or more
(Service space)
B view
40
2X65=130
6
635
1185
3 65=195
2
(SAME AS THE INDOOR
UNIT SIZE OR MORE)
20-8X12 oblong hole
(All around)
1160
212
144
5
3
135 120
67
150
200
300
245
215
150
135
57
Service space
300 or more
6-M5 Hole
(Circumference)
1
2 65=130
Suspension bolt
25
(467 or less)
50
65
800
440
315
Air inlet
Fig.A
9
Fresh sir intake position
700 or less
232 Adjustable
25
60
Unit base
Air outlet
Air inlet
100
10
Inspection hatch
Ceiling
Control box
1400
or more
600
Control box
20
or more
160 P.C.D.
125
Inspection hatch 1
(450mmX450mm)
48- 4.7 Hole
(All around)
300 or more
(Note.4)
2500 or more
(A case without
the ceiling)
H
160
228
I
J
(Suspension position)
Air outlet
CASE 1)
10
200
or less
631
(Hanging bolt pitch)
300
or more
27
9
300
Service space
Note)2
View B-2
1
2
3
4
6X150=900
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)
2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)
3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
40- 4.7 Hole
(All around)
(Knock hole)
Notes:
1
Location of unit's Name Plate: Fan hosing surface.
2
If the ceiling is not removable, a 300 mm service space
must be kept between the unit and the ceiling.
3
Mount the air filter at the suction side.
(Select its colorimethod (Gravity method) 50 % or more)
700
or more
[FBQ100/125/140DV1]
8
A view
F
G
513
80
630
(Suspension position)
27
47
3X65=195
7 4
28
12
300
300 or more
(Note.4)
2500 or more
(A case without
the ceiling) 150
277
247
150
212
144
169
11
290
300
or less
245
215
150
145
C
B
Air inlet
(Note.2)
5
8
E
300
or more
200
or less
65
2 6
Ceiling
700
Inspection hatch 2
or more
(SAME AS THE INDOOR
UNIT SIZE OR MORE) View B-1
18-8X12 oblong hole
(All around)
150
277
247
150
7
150
208
1
B
Inspection hatch
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
A
B
250
3
Control box
Inspection hatch 3
(SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
Control box
Control box
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
[FBQ50/60/71BV1A]
D
1000
805
245
215
150
CEILING MOUNTED BUILT-IN TYPE
49
5X150=750
(From the Air outlet)
1205
16X65=1040
9
Notes:
1
In case of back-suction, mount chamber cover to bottom side of the unit.
In case of bottom-suction, mount chamber cover to back side of the unit.
2
Location of unit's Name Plate: control box cover.
3
Mount the air filter at the suction side.
(Select its colorimethod (Gravity method) 50 % or more)
It can not be equipped with air filter (accessory) when connecting duct to suction side.
Inspection hatch 1
(450mmX450mm)
950
Ceiling
(From the Air inlet)
Floor surface
Notes:
1
Location of MANUFACTURE'S LABEL: Contro box surface
2
Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.)
3
Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.
4
Space for Service Works
1438(Hanging bolt pitch)
10
20
50
6
130
100
90
80
Fig.A
CASE 2),3)
700 or more
(Service space)
Air outlet
40
2X65=130
10
Air inlet
Air outlet
785
167
24-M5 Holes
(All around)
9xP100=900
980
1000
1020
450 or more
(Service space)
59
Adjustable
9
(467 or less)
9xP100=900
980
1000
1020
《In case of back-suction》
Control box
Unit base
Inspection hatch Ceiling
760
Inspection hatch 450 or more
700 or less
100
100
160
180
150
100
90
80
7
5
3
16-8X12 oblong hole
(All around)
View
232
10
23
330
Air inlet
Inspection hatch 1
(450mmX450mm)
9
50
20
10
24-M5 Holes
(All around)
4
Control box
435
1
130 63
170
47
90
2
30
18-M4 Holes
(All around)
Air outlet
Inspection door
(ceiling opening)
1080
1060
6xP150=900
30- 4.7 Hole
(All around)
8
1300
or more
A
《Service space》
10
631
(Hanging bolt pitch)
11X65=715
1100
240 or more
Ceiling
Liquid pipe connection
Gas pipe connection
Socket for drain
Drain hose (Standard accessory)
Control box
Infrared receiver unit connection
Power supply connection
Suspension bracket
Air filter (Standard accessory)
Protection net
1038(Hanging bolt pitch)
20 or more
20 or more
500
(Suspension bolt pitch)
57.5
1
2
3
4
5
6
7
8
9
10
Allow view A
80
12.5
21
Suspension bolt
4-M8~M10
27
30- 4.7 Hole
(All around)
400 or more
(In case of
bottom suction)
60
620
(All around)
26-o/ 4.7 Hple
10xP100=1000
1140
(Suspension bolt pitch)
8
200
170
153
620
300 or more
(Service space)
1100
13X65=845
[FDXS60CVMA]
1
2
3
4
5
6
7
8
9
10
11
12
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Earth terminal
(Terminal in Control box)
Control box(Inside)
Remote control wiring
connection
Power supply wiring and a
transmission wiring
Air discharge flange
Air suction flange
Hanger
Socket (for maintenance)
Drain hose(Accessory)
48
DIMENSIONS
(Unit: mm)
FLOOR STANDING TYPE
OUTDOOR UNIT // RKS50/60AVMG, RXS50FAVMA, RXS50/60FVMA
[FVQ50/60CVE, 71/100/125/140CVEB]
825
260
In case of fixing it at the bottom
In case vibration resistance is
required, fix it at both the bottom
and the rear.
330
Fixture
(Accessory)
re
1
0
50
or
mo
Required space
184
E
45
44
F
50
49
G
H
J
K
L
50 110 180 186 242
130 190 260 266 322
M
57
79
89 64
50
N
P
144 149
202 229
50
50
OUTDOOR UNIT // RXS71FVMA
900
620
140
105.5
4–cuts for anchor bolts
(M12)
376
30
320
350
(345-355)
380
117 102 71
13
29.5
30
45
191
Drain outlet
(I. D o/ 25 hose for connection)
Brand name label
765
12
Name plate
63
Gas stop valve
Terminal strip
with earth terminal
Liquid stop valve
Outdoor air
thermistor
Outdoor air thermistor
Manufacture's
Label
Liquid
stop valve
( 6.4CuT)
Gas stop valve
( 9.5CuT)
104
90
30
67
Interconnecting piping
and wiring inlet
Gas pipe
(o/ 15.9 single union)
Liquid pipe
(o/ 6.4 single union)
50
100
100
Wall height on air outlet side
=less than 1200
Minimum space for air passage
350
150
50
50
50
100
50
350
50
300
100
126
50
105
165
78
108
100
Minimum space for air passage
22
350
Wall height on air outlet side
=less than 1200
196
In case of removing
stop valve cover
150
Indication label
410
770
550
Wiring
inlet
Service
port
50
Gas stop valve (o/ 12.7 CuT)
490
Handle
8
18
30
100
Minimum space for air passage
4 - Holes for anchor bolts
(M8 or M10)
574
Wall height on air outlet side
=less than 1200
155
160
100
75
184
Liquid
stop valve
(o/ 6.4CuT)
Service port
350
100
H
J
K
L
OUTDOOR UNIT // RKS25/35AVMG, RXS25/35EBVMA
285
Terminal strip with earth terminal
350
6
6
A
B
C
D
FVQ50/60CVE, 71CVEB 50 110 186 270
FVQ100/125/140CVEB
130 190 266 350
(I.D φ15.9 hose for connection)
Outdoor air temperature thermistor
Wiring inlet
Brand name label
350
4
50
541
616
95
200
223
253
34
6
95
825
50
3
5
F
Drain outlet
In case of removing
stop valve cover
Name plate
100
G
598
311
mo
735
Full open
position of
suction grille
Notes:
1
Sticking location for manufacturer’s label: on the surface of
cover of switch box inside the suction grille.
or
1 Suction grille
2 Air filter
3 Through hole for side piping
(70x90 oblong slit hole)
4 Through hole for side piping
( 80 slit hole)
5 Through hole for side piping
( 27 slit hole)
6 Through hole for rear
piping/wiring
(80x130 oblong slit hole)
7 Through hole for bottom
piping/wiring
(126x130 square hole)
8 Liquid pipe connection
9 Gas pipe connection
10 Drain pipe connection
1
E
100
C
50
re
2-7X15
oblong hole
(For wood screw)
Approx.46
A
B
mo
4 –Holes for anchor bolts
(M8 or M10)
2
9
10
580
re
740 or more
(Pull out dimension of air-filter)
314
677
1850
8
or
300
D
Pull out
direction
of air-filter
18
68
600
50
330
350
View
30
Detail
(Two both sides)
124
Drain outlet
(I.D. o/ 15.9 hose for connection)
25
130
N
P
7
0.7
2
36
126
78
325
This model to be fixed with fixture
as shown below.
M
Suction grille
stopper
130 215
10
4- 14 Hole
(For bolt)
49
50
DIMENSIONS
(Unit: mm)
OUTDOOR UNIT // RZR50/60LUV1V, RZR50/60/71LVVM
OUTDOOR UNIT // RZR125/140LVVM, RZR100/125/140LUY1
131
573.5
320
43
300
61
78
350
(345~355)
845
30
Hole for anchor
bolt 4-M12
Drain outlet
I.D. 18 hose for connection
140
620
20
Hole for anchor bolts
(M8 or M10)
Name plate
140
900
30
7
30
300
326
342
41
94
4
3
Earth terminal
in switch box
Wiring inlet
2
1
5
89
55
53
19
19
142
8
71
Drain outlet
80
52
145
13
299
419
449
5
479
509
559
45
376
67
16
58
70 102 117
200
95
223
95
54
89
60
84
95
54
20
16
94
6
55
422
423
105
144
Service port
21
6
5
Gas stop valve
( 15.9CuT)
Drain outlet
7
5
Liquid stop valve
( 9.5CuT)
272
112
163
269
Service port
7
6
60
595
1170
7
191
1
2
3
4
5
6
7
8
Gas pipe connection
Liquid pipe connection
Service port
Earth terminal
Refrigerant piping intake
Power supply wiring intake
Transmission wiring intake
Drain outlet
1
2
3
4
5
6
7
8
Gas pipe connection
Liquid pipe connection
Service port
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain outlet
OUTDOOR UNIT // RZQ50/60KBV1V, RZQ50/60KBV4A, RZQ71KCV4A
OUTDOOR UNIT // RZR100LVVM
Hole for anchor
bolt 4-M12
320
91
160
41
140
3
94
140
620
900
30
3
4
2
1
7
6
5
4
7
6
5
6
5
416
595
51
55
19
13
71
8
67
1
2
3
4
5
6
7
8
Gas pipe connection
Liquid pipe connection
Service port
Earth terminal
Refrigerant piping intake
Power supply wiring intake
Transmission wiring intake
Drain pipe connection
223
53 95
339
54 95
60
89
28
95
89
19
142
52
16
68
161
260
279
285
262
5
80
52
145
13
67
16
16
145
5
36
61
6
55
223
55
84
53
80
117
90
19
16
8
340
95
339
95
142
7
58
6
19
70 102
7
89
53
89
60
5
53
990
1
770
7
2
54 95
84 55
620
940
341
160
30
30
43
61
30
38
350
(345~355)
320
55
37
30
350
(345~355)
30
Hole for anchor bolt 4-M12
5
45
376
191
52
DIMENSIONS
(Unit: mm)
OUTDOOR UNIT // RZQ100/125/140KCV4A
REMOTE CONTROLLER
30
Hole for anchor
bolt 4-M12
Remote controller dimensions
•
CEILING MOUNTED CASSETTE TYPE <Round Flow>
• Receiver installation procedure
Transmitting part
Refrigerant piping
side
157
140
900
30
Drain piping
side
Refrigerant
piping side
94
620
140
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
• Receiver installation procedure
Receiver
30
41
320
43
61
350
(345~355)
Wireless type
Receiver
3
4
Drain piping
side
2
62
17.5
1
1170
Remote controller holder
installation procedure
<installation to wall surface>
•
7
7
6
7
6
6
5
55
Remote controller
holder
95
223
84
95
CEILING MOUNTED BUILT-IN TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
53
54
54
(BYFQ60BW1)
(BYFQ60B7W1)
(BYFQ60B8W1)
55
423
422
95
60
89
89
•
19
19
80
52
145
13
CEILING SUSPENDED TYPE
• Receiver installation procedure
Receiver detail
2-5x9 Slot
The Front
142
5
45
376
191
70
18
0.5
35
(Ceiling opening)
Gas pipe connection
Liquid pipe connection
Service port
Grounding terminal
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain outlet
72
83.5
106
1
2
3
4
5
6
7
8
58
70 102 117
16
16
Receiver
67
120
71
8
Decoration panel
• Receiver detail
Liquid crystal
remote controller
(wireless)
5
5
Decoration panel
• Receiver detail
49
• Receiver detail
(Ceiling opening)
Switch box
(field Supplied parts)
More than 90
(Srevice space)
Service space for ceiling installation
OUTDOOR UNIT // RZQ100/125/140HAY4A
Note :
Do not install more than 3 receivers in
the vicinity of one another.
With 4 or more units, there is always
the possibility of malfunction
Wired type
• Remote controller dimensions
BRC1C61
36
55
320
• Installation method
42
900
117
84
17
3
18
Cord
outlet
hole
23 28
(Between remote
controller and
control box)
17
16
58
71 102 117
5
53
191
Note)
1. Remote controller cord and staple are not
attached.
They are field supplied parts.
B Embedded cord
Staple
Condit
C Embedded cord
(use switch box)
19
19
42
Top center
outlet
84
84
40
95
84
95
2
40
55
500 m
A Exposed cord
Operation
lamp
(Green)
Code outlet hole
120
19
5X7 oblong hole
80
52
145
13
1
2
3
4
5
6
7
8
28
23
46
5X15 oblong hole
48.5
48.5
Left outlet
19
Lower case portion
Note)2
28
Through hole
Switch box for one switch
( 8- 10)
ex.) KJB111A
(optional accessory)
Lower case
67
8
376
0.75~1.25 mm
55
435
19
16
Size
Total length
Top left
outlet
53
54
54
95
416
60
89
24
5
Shield wire (insulated thickness: 1 mm or more)
• Installation method
Lower case
6
6
5
Upper case
120
5
BRC1E62
7
7
6
223
1345
7
19
Control box
Type
1
Through hole
( 12- 16)
Specifications of cord
2
142
17
46
4
71
Remote
controller
0~5
120
89
C Exposed body, embedded code
Conduit
38
140
620
(Pitch of foundation bolt holes)
30
45
17
Remote
controller
Remote
controller
120
91
140
B Exposed body, embedded cord
Staple
30
38
A Exposed body, exposed cord
84
(Pitch of foundation bolt holes)
350
(345~355)
30
Hole for anchor
bolt 4-M12
Gas pipe connection
Liquid pipe connection
Service port
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection
Note)
1. Remote controller cord and staple are not attached. They are field
supplied parts.
Specifications of cord
Type
Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size
0.75~1.25 mm2
Total length
500 m
46
0~5
Switch box for two switch (Between remote
ex.) KJB211A
controller and
(optional accessory)
control box)
Switch box
portion
[field supplied part]
2.If the hole size is too large or the location
is not proper, the hole may come out from
the remote controller.
54
Installation service space for outdoor unit
For RZR50/60LU/LV, 70-140LVVM, RZR100-140LUY1
For RZQ50/60KBV1V/V4A, RZQ71-140KCV4A, RZQ100-140HAY4A
2.RZR100-140LVVM, RZR100-140LUY1
The values represent the case for the RZQ100-140KCV4A and RZQ100-140HAY4A. The dimensions in ( ) are for the RZQ50/60KB and RZQ71KCV4A (The unit values is mm. )
2 When there is an obstruction on the outlet side
1) When the overhead space is open
1) When the overhead space is open
1. For single unit installation
1
2
re
or
mo
0
10 ore
m
or
1
25
0o
ore
25
0o
rm
10
ore
0o
rm
10
0
1
or
0
10 ore
m
or
mo
re
0
00
or
mo
re
1
0
00
or
mo
re
100
ore
or m
50
0
le
or
ss
1
An obstruction
in the overhead
space
50
0
le
or
10
ore
0o
rm
2
10
0
mo or
re 10
0
mo or
re
When there are
obstructions on
both sides
10
00
0
30 ore
m
or
0o
rm
ore
50
r
0o
mo
re
50
0
m
or
0o
ore
0)
0(
0
50
m
or
2. For multiple units installation
(more than two units)
30
or 250
mo
re
0o
0o
rm
ore
0o
rm
An obstruction
in the overhead
space
ore
0
10
0o
0
rm
2) When there is an obstruction
in the overhead space
0
10 ore
m
or
50
0
le
or
ss
2
rm
When there is an
obstruction on the
inlet side
ore
3 When there are obstructions on both
the inlet and outlet sides
(When the obstruction on the outlet side is higher than the
unit itself)
1) When the overhead space is open
ore
1. For single unit
installation
1
1
or 000
mo
re
or 250
mo
re
50
0
or
s
les
An obstruction
in the overhead
space
0
20 ore
m
or
r le
re
ss
When there are obstructions
on the inlet side and
both sides
An obstruction
in the overhead
space
50
150
or m
10
0o
0o
r le
0o
rm
1
or
rm
ss
0
00
or
re
mo
e
3 When there are obstructions on both
the inlet and outlet sides
(When the obstruction on the outlet side is higher than the
unit itself)
1) When the overhead space is open
(There is no limit to the height of the obstruction on the
outlet side.)
ore
150
e
or
rm
1. For single unit installation
o
50
or m
ore
1
2. For multiple units installation (more than two units)
L
0o
1
H
An obstruction
in the overhead
space
10
2
H
10
0
mo or
re
50
0o
r le
10
00
or
mo
or 200
mo
re
0
30 ore
m
or
20
ore
rm
ore
00
10 ore
m
or
0
20 ore
m
or
55 Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
L
H
00
10 ore
m
or
0o
)
50
0 ( re
10 mo
or
10
0
mo or
re 10
0
mo or
re
rm
ore
rm
0o
2. For multiple units installation
(more than two units)
re
0o
25
ss
0
50 ore
m
or
L
When there are obstructions
on the inlet side and
both sides
1000 or more
H
L
50
s
1
or 000
mo
re
or 250
mo
re
L
0
10 ore
m
or
0
50 ore
m
or
2. For series installation (more than two units)
s
r le
1000 or more
r
1000 or more
An obstruction
in the overhead
space
2
0o
mo
2
50 ore
m
0 e or
0
5 or
m
or
When there are obstructions on the inlet side and
both lateral sides
s
les
ss
L
0
15 ore
m
or
or 150
mo
re
2. For series installation (more than two units)
1
r le
ore
1. For single unit installation
(There is no limit to the height of the obstruction on the
outlet side.)
or 150
mo
re
or
0o
An obstruction
in the overhead space
L
15
0o
ore
10
0
mo or
re
ss
10
ore
in the overhead
space
1000 or more
0o
50
25
50
2
le
or
H
s
s
r le
s
0
10
When there are obstructions on the inlet side and
both lateral sides
An obstruction
50
50
1000 or more
1000 or more
0o
s
1000 or more
m
An obstruction
in the overhead
space
les
1000 or more
10
r
0o
50
r
0o
1000 or more
2
1000
or more
0o
50
rm
1. For single unit installation
20
rm
ore
1000 or more
50
1
s
r le
ore
mo
20
20
When there is an obstruction on the inlet side
or 150
mo
re
50
ore
1. For single unit installation
r le
0o
re
2) When there is an obstruction in the overhead space
1
0
10
2. For series installation (more than two units)
1
rm
An obstruction
in the overhead space
or
00
o
0
20 ore
m
or
ss
0o
10
0
mo or
re 10
0
mo or
re
ore
2. For multiple units installation
(more than two units)
ss
ore
or 250
mo
re
2. For multiple units installation
(more than two units)
2) When there is an obstruction
in the overhead space
rm
or 250
mo
re
mo
or
or m
100
2
10
0
)
(50
10
2) When there is an obstruction in the overhead space
When there are obstructions on both sides
1
50
re
1. For single unit installation
2. For series installation (more than two units)
1
or 000
mo
re
rm
rm
ore
When there is an
obstruction only
on the inlet side
ore
When there are obstructions
on both sides
0o
ore
rm
1000 or more
ore
0o
H
rm
2
10
50
1. For single unit installation
2
1000 or more
0o
1. For single unit installation
2. For series installation (more than two units)
When there are obstructions on
both sides
1
1) When the overhead space is open
1) When the overhead space is open
2
0
50 ore
m
or
50
10
1
2 When there is an obstruction on the outlet side
H
When there is an
obstruction only
on the inlet side
1. For single
unit installation
1 When there is an obstruction on the inlet side
1000 or more
1 When there is an obstruction on the inlet side
1000 or more
1.RZR50/60LU/LV, RZR71LVVM
0)
20
0 ( re
30 r mo
o
L
H
0
30 ore
m
or
00
10 ore
m
or
0)
20
0 ( re
30 r mo
o
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
56
MEMO
57
58