Download Daikin FBQ50BV1A User`s manual
Transcript
PCSVN1412 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Đại lyù phaân phoái: AIR CONDITIONING SYSTEM COOLING ONLY [50Hz] HEAT PUMP [50Hz] TRUNG TÂM DICH VU KHÁCH HÀNG Miễn phí cöôùc cuoäc goïi Specifications, designs and other content appearing in this brochure are current as of May 2014 but subject to change without notice. c All rights reserved 05/14 SS Daikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies. CEILING MOUNTED CASSETTE TYPE Round Flow COMPACT MULTI FLOW CEILING NG MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE 1 CEILING MOUNTED SLIM DUCT TYPE CEILING MOUNTED BUILT-IN TYPE DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE FLOOR STANDING TYPE 2 Product Lineup Series 25 Cooling only 35 50 60 71 100 125 140 FCQ71LUV1 RZR71LVVM FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 CEILING MOUNTED CASSETTE TYPE Page 9 Round Flow FCQ50LUV1V RZR50LUV1V NEW Indoor unit Outdoor unit FCQ60LUV1V RZR60LUV1V NEW RZR100LVVM RZR100LUY1 RZR125LVVM RZR125LUY1 RZR140LVVM RZR140LUY1 COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit Page 13 FFQ25BV1B RKS25AVMG FFQ35BV1B RKS35AVMG FFQ50BV1B RKS50AVMG FFQ60BV1B RKS60AVMG FHQ35BVV1B RKS35AVMG FHQ50BVV1V RZR50LUV1V FHQ60BVV1V RZR60LUV1V Pair CEILING SUSPENDED TYPE Page 15 Indoor unit Outdoor unit NEW NEW FHQ71BVV1B RZR71LVVM FHQ100BVV1B RZR100LVVM RZR100LUY1 FHQ125BVV1B RZR125LVVM RZR125LUY1 NEW FHQ140CAVEB RZR140LVVM DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Page 19 FBQ50DV1V RZR50LUV1V NEW Indoor unit Outdoor unit FBQ60DV1V RZR60LUV1V NEW FBQ71DV1 RZR71LVVM FBQ100DV1 RZR100LVVM RZR100LUY1 FBQ125DV1 RZR125LVVM RZR125LUY1 FBQ140DV1 RZR140LVVM RZR140LUY1 FLOOR STANDING TYPE Page 21 FVQ50CVE RZR50LVVM NEW Indoor unit Outdoor unit FVQ60CVE RZR60LVVM NEW FVQ71CVEB RZR71LVVM FVQ100CVEB RZR100LVVM RZR100LUY1 FVQ125CVEB RZR125LVVM RZR125LUY1 FVQ140CVEB RZR140LVVM RZR140LUY1 CEILING MOUNTED CASSETTE TYPE Page 9 Round Flow Indoor unit RZR125LVVM Outdoor unit Simultaneous Twin Multi FCQ60LUV1X2 NEW RZR125LUY1 NEW FCQ71LUV1X2 RZR140LVVM RZR140LUY1 CEILING SUSPENDED TYPE Page 15 NEW Indoor unit FHQ60BVV1GX2 RZR125LVVM Outdoor unit RZR125LUY1 NEW FHQ71BVV1BX2 RZR140LVVM RZR140LUY1 DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Page 19 NEW Indoor unit FBQ60DV1X2 RZR125LVVM Outdoor unit RZR125LUY1 NEW FBQ71DV1X2 RZR140LVVM RZR140LUY1 FLOOR STANDING TYPE Page 21 NEW Indoor unit FVQ60CVEX2 RZR125LVVM Outdoor unit RZR125LUY1 NEW FVQ71CVEBX2 RZR140LVVM RZR140LUY1 OUTDOOR UNIT Page 23 Outdoor unit NEW RZR50LUV1V/LVVM NEW RZR60LUV1V/LVVM NEW RZR71LVVM NEW RZR100LVVM RZR100LUY1 NEW RZR125LVVM RZR125LUY1 NEW RZR140LVVM RZR140LUY1 OUTDOOR UNIT Outdoor unit 3 RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG 4 Product Lineup Heat pump 25 Series 35 50 60 71 100 125 140 CEILING MOUNTED CASSETTE TYPE Round Flow Page 9 FCQ50LUV1V RZQ50KBV1V Indoor unit NEW Outdoor unit FCQ60LUV1V RZQ60KBV1V NEW FCQ71LUV1 RZQ71KCV4A FCQ100LUV1 RZQ100KCV4A RZQ100HAY4A FCQ125LUV1 RZQ125KCV4A RZQ125HAY4A FCQ140LUV1 RZQ140KCV4A RZQ140HAY4A COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit Page 13 FFQ25BV1B RXS25EBVMA NEW FFQ35BV1B RXS35EBVMA NEW FFQ50BV1B RXS50FVMA NEW FFQ60BV1B RXS60FVMA NEW CEILING SUSPENDED TYPE Page 15 FHQ35BVV1B RXS35EBVMA Indoor unit NEW Outdoor unit FHQ50BVV1V RZQ50KBV1V NEW FHQ60BVV1V RZQ60KBV1V NEW FHQ71BVV1B RZQ71KCV4A FHQ100BVV1B RZQ100KCV4A RZQ100HAY4A FHQ125BVV1B RZQ125KCV4A RZQ125HAY4A NEW FHQ140CAVEA RZQ140KCV4A RZQ140HAY4A Pair CEILING MOUNTED SLIM DUCT TYPE Page 17 Indoor unit Outdoor unit FDXS25CVMA RXS25EBVMA NEW FDXS35CVMA RXS35EBVMA NEW FDXS50CVMA RXS50FAVMA NEW FDXS60CVMA RXS60FVMA NEW CEILING MOUNTED BUILT-IN TYPE Page 18 FBQ50BV1A RXS50FAVMA Indoor unit Outdoor unit FBQ60BV1A RXS60FVMA FBQ71BV1A RXS71FVMA DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Page 19 FBQ50DV1V RZQ50KBV1V Indoor unit NEW Outdoor unit FBQ60DV1V RZQ60KBV1V NEW FBQ71DV1 RZQ71KCV4A FBQ100DV1 RZQ100KCV4A RZQ100HAY4A FBQ125DV1 RZQ125KCV4A RZQ125HAY4A FBQ140DV1 RZQ140KCV4A RZQ140HAY4A FLOOR STANDING TYPE Page 21 FVQ50CVE RZQ50KBV4A NEW Indoor unit Outdoor unit FVQ60CVE RZQ60KBV4A NEW FVQ71CVEB RZQ71KCV4A FVQ100CVEB RZQ100KCV4A RZQ100HAY4A FVQ125CVEB RZQ125KCV4A RZQ125HAY4A FVQ140CVEB RZQ140KCV4A RZQ140HAY4A OUTDOOR UNIT Page 23 Outdoor unit NEW RZQ50KBV1V/KBV4A NEW RZQ60KBV1V/KBV4A RZQ71KCV4A RXS60FVMA RXS71FVMA RZQ100KCV4A RZQ100HAY4A RZQ125KCV4A RZQ125HAY4A RZQ140KCV4A RZQ140HAY4A OUTDOOR UNIT Outdoor unit 5 RXS25EBVMA RXS35EBVMA RXS50FVMA/FAVMA 6 Energy saving Wider lineup of inverters Achieved higher COP Daikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies. COP 3.70 3.57 3.60 Total of 104 combinations! 3.40 25 COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE FCQ50LUV1V FCQ60LUV1V RZR50LUV1V RZR60LUV1V What is COP (Coefficient of Performance) CEILING MOUNTED CASSETTE TYPE Round Flow Note : *Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). : Cooling only 35 50 60 71 100 : Heat pump 125 140 1 Phase CEILING MOUNTED CASSETTE TYPE Round Flow 1 Phase CEILING SUSPENDED TYPE 1 Phase 3 Phase 3 Phase Pair Cooling* Cooling* Cooling* 2 Cooling* 2.85 Cooling* 3 3.84 Cooling* 4 FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance. CEILING MOUNTED SLIM DUCT TYPE 1 Phase CEILING MOUNTED BUILT-IN TYPE 1 Phase DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE 1 Phase FLOOR STANDING TYPE 1 Phase 3 Phase 3 Phase CEILING MOUNTED CASSETTE TYPE Round Flow New types of indoor units 3 Phase CEILING SUSPENDED TYPE NEW Twin NEW 1 Phase 1 Phase 3 Phase DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE 1 Phase FLOOR STANDING TYPE 1 Phase 3 Phase 3 Phase Ceiling mounted slim duct type 2.5-6.0 kW class Comfortable Comfortable currents of air are sent to every corner of the room. Refrigerant branch piping kit for Twin Multi operation 7 Page 28 For example, four indoor units are judiciously spaced in this wide single-floor restaurant to deliver comfortable currents of air to every corner of the room. Enhanced comfort with Inverter Inverter performs variable control of frequency, which determines air conditioner’s power performance. At startup, full power is used to achieve the set temperature quickly. Then, the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control resulting in a more stable room temperature. Non-inverter type air conditioners must be switched on and off repeatedly, causing large fluctuations of the room temperature. 2 sets of Twin Multi Cooling operation At startup, inverter raises frequency smoothly, eliminating the starting current spike. Non-inverter Current Simultaneous twin multi operation Running current Temp Inverter Starting current Time Current Ceiling suspended type 14.0 kW class Set temp Cools a room in less time Small temp. difference Time Inverter power control Non-inverter type air conditioner Running current Time 8 CEILING MOUNTED CASSETTE TYPE Round Flow Avoids uneven temperature and discomfort caused by drafts. Cassette air conditioner with 360° uniform airflow sets the standard Comfort enhanced by Round Flow! Cooling only / Heat pump FCQ50/60LUV1V FCQ60/71/100/125/140LUV1 360° airflow Air movement is gentle with Round Flow With uniform temperature distribution Enhanced Comfort 360° airflow can maintain comfort even if air discharge speed is lower. Airflow distribution Creates uniform comfort throughout the space If you raise the set temperature by 1 to 1.5°C,and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort. Greater comfort Improved energy saving Option Accessory required for indoor unit. Wired LCD remote controller Adapts easily to the installation space. BRC1C61 Note: Remote controller cable not included. Cables must be procured locally. Because air flows out from corner outlets, comfort spreads more widely. Typical flow patterns There are a total of 23 flow patterns. Navigation Remote Controller (Wired Remote Controller) All-round flow 3-way flow (E.g., installed in middle of ceiling) (E.g., installed near a wall) L-shaped 2-way flow Opposite 2-way flow BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. Wireless LCD remote controller Heat pump Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound increases when using 2-way or 3-way flow. BRC7F633F BRC7F632F Grime prevention and bactericidal coating: Make cleaning easier. Signal receiver unit (Installed type) External panels are treated with a coating that Treated Untreated repels dirt. surface surface Wireless remote controller and signal receiver unit are sold as a set. Features *1Applicable when wired remote controller is used *2For the outdoor units *3Applicable when BRC1E62 is used *4Applicable when BRC1C61 is used 9 • • • • • • *2 • • • • • • *2 Fresh air intake kit • • • • • • • • • • • • • • • • • • • • • • • • • --- Others Anti corrosion treated heat exchangers *4 High-efficiency filter *3 Ultra long-life filter *3 Interlock control *3 Options DIII-NET communication standard *3 Central remote control *2 Auto-restart • • *2 Auto-cooling/heating change-over Control by 2 remote controllers Group control by 1 remote controller External command control *1 *2 Control features Self-diagnosis function *4 Emergency operation *3 Low gas pressure detection *3 Ceiling soiling prevention *3 Filter sign On/Off timer *3 Long-life filter Off timer (programmed) *2 Pre charged for up to 30 m Weekly schedule timer --- Drain pump mechanism Setpoint range set --- Silver ion anti-bacterial drain pan Night quiet operation Setpoint auto reset *1 Work & Servicing Cleanliness Anti-bacterial air filter Year-round cooling applicable High ceiling application Programme "Dry" Draft prevention function (heating) Switchable fan speed (2 step) • • • • • • • • • • • Hot start (after defrost) Heat pump --- Remote controller Two selectable temperature-sensors Cooling only Swing pattern selection Auto swing Comfort (E.g., installed in a long room) 4-way flow also possible. A signal receiver must be added to the indoor unit. Cooling only (E.g., installed in a corner) *2 *2 To prevent dirt sticking to the external panels, they have been coated with a surface treatment. Resists soiling Grimy surface • Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space. Silver ion anti-bacterial drain pan Non-flocking flaps Filter has anti-mould and bactericidal treatment Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters. 10 CEILING MOUNTED CASSETTE TYPE Fine square panels Compact body and quiet operation mm 95 0m Same for all models m Indoor unit High Low 50LUV1V 60LUV1V/V1 71LUV1 100LUV1 125LUV1 140LUV1 35 35 35 43 44 44 28 28 28 32 34 36 Optimal comfort and convenience assured by air discharge modes Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller. Air direction Standard setting Setting to prevent soiling of ceiling* Desired situation Standard position to prevent draft. Recommended for shops with light coloured ceilings that must be kept spotless. Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Quick and easy to install 5-levels air direction setting Auto-swing between 15° and 60° Auto-swing between 25° and 60° Settable to 5 different levels between 25° and 60° Settable to 5 different levels between 15° and 60° The air direction is set automatically to the memorised position of the previous air direction. Auto air direction control *Closing of the corner discharge outlets is recommended. Suitable for high ceilings Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level. Criteria for ceiling height and number of air discharge outlets (Ceiling height is reference value) Number of air discharge outlets used Standard Ceiling High ceiling height High ceiling 50/60LUV1V, 60/71LUV1 100–140LUV1 All round 4-way 3-way 2-way flow flow flow flow All round 4-way 3-way 2-way flow flow flow flow 2.7 m 3.1 m 3.0 m 3.5 m 3.0 m 3.4 m 3.3 m 3.8 m 3.5 m 4.0 m 3.5 m - 3.2 m 3.4 m 3.6 m 4.2 m 3.6 m 3.9 m 4.0 m 4.2 m 4.2 m 4.5 m 4.2 m - The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille. 256 mm *1 266 mm *2 Easy height adjustment Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets. All models can be installed without using lifter because of the light weight. Installable in any direction Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. Drain pump is equipped as standard accessory with 850 mm lift. Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Switchable fan speed: High/Low High setting provides maximum reach while low setting minimises drafts. On/Off timer Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses. 11 Drain plug Options required for specific operating environments Ultra long-life filter Panel spacer Even in smoky environments where the air conditioning is on most of the time, the ultra long-life filter only has to be changed once a year. Use when only minimal space is available between drop ceilings and ceiling slabs. Smoky atmosphere: annual filter change *For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year 40mm Ordinary store or office: filter change every 4 years Panel spacer *For dust concentration of 0.15 mg/m3 4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit. High-efficiency filter Available in two types: 65% and 90% colorimetry. Sealing material of air discharge outlet Fresh air intake kit Using this kit, a duct can be fitted to increase the intake of outdoor air. Outside A round duct can be attached without the need for a chamber. Chamber type (without T-joint pipe and fan) 850 mm 175 mm Because the drain socket is transparent, after the drain piping has been installed, it is easy to check if the drain come out through the socket. A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole). The units can be installed in the following different ways. Chamber type (with T-joint pipe and without fan) KDDP55B160 Transparent drain socket Sealing material block air discharge openings not used in 2-way or 3-way blow. Branch duct (direct-connection round duct) Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending. Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting. Two selectable temperature-sensors e en th ! p o t e Jus ke grill inta With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years. Just 256 mm high. Installable in tight ceiling spaces (50/60LUV1V, 60/71LUV1) *1 298 mm high with 100–140LUV1 *2 308 mm high with 100–140LUV1 Auto-swing Easier to maintain dB(A) Panel size is same for all models, FCQ50/60LUV1V, 60-140LUV1. It is easy to maintain a neat appearance when multiple units are installed. 950 Round Flow KDDP55B160K Flexible duct (procured locally) Flexible duct T-joint pipe (procured locally) T-joint pipe Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Direct installation type KDDP55X160 Duct flange (with insulation material) Intake duct (procured locally) Note: Use of options will increase operating sound. Connection to a centralised control system is available without option Low gas pressure detection 12 CEILING MOUNTED CASSETTE TYPE COMPACT MULTI FLOW Quiet decor-blending form and easy installation in new or old buildings Compact Comfortable Sized to fit inside 600mm wide ceiling grids Designed for low draft performance 0° 575 mm Cooling only / Heat pump 286 Less draft can be felt tion Decolrais also e n pa ct. compa mm Consistent comfort throughout Auto-swing operation distributes conditioned air more evenly. 700 mm Fits without the need to cut T-bar grid Ceiling panel Standard setting T bar 600 mm (Set on site) The switch box is built in to the unit, so maintenance is possible by simply removing the grill. An inspection opening is not required even for modules other than 600 x 600. Setting to prevent soiling of ceiling (Set on site) BRC1E62 Quiet, small-diameter fan 3-way flow Quiet operation has been achieved even with a compact body and developed spiral hub cover that reduces the static pressure inside the indoor unit. 4 patterns Spiral hub cover Features *1Applicable when wired remote controller is used *2Applicable when outdoor temperature is from 10 to 46°CDB *3Applicable when BRC1E62 is used 13 • • • • • • *4Applicable when BRC1C61 is used *5For the outdoor units *5 *5 Option Others Anti corrosion treated heat exchangers Fresh air intake kit Interlock control Central remote control • • • • • • • • • • • • • • • • • • • • • • • --- Indoor unit High Low 25B 29.5 32 36 41 24.5 25 27 32 35B 50B External command control Group control by 1 remote controller Control by 2 remote controllers Auto-cooling/heating change-over • *4 Auto-restart *4 *3 Control features Self-diagnosis function *3 *3 Ceiling soiling prevention On/Off timer *3 *3 Filter sign Off timer (programmed) *3 *3 Long-life filter Weekly schedule timer *3 *2 Pre charged for up to 10 m Setpoint range set *2 Drain pump mechanism Setpoint auto reset --- *1 Mould-proof drain pan Year-round cooling applicable *1 Anti-bacterial air filter Hot start (after defrost) --- Two selectable temperature-sensors Programme "Dry" Switchable fan speed (2 step) Draft prevention function (heating) Swing pattern selection Auto swing • • • • • • • • • Settable to 5 different levels between 25° and 60° Air direction can be selected according to installation. Note: Operation sound increases when using 2-way or 3-way flow. Two selectable temperature-sensors dB(A) Heat pump 60° Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s). Wireless remote controller and signal receiver unit are sold as a set. Cooling only 25° Auto-swing between 25° and 60° " " denotes piping direction. Drain piping " " denotes sealing member for air discharge outlet (option) . BRC7E531W BRC7E530W Signal receiver unit (Installed type) Work & Servicing 60° Settable to 5 different levels between 0° and 35° 1 pattern A signal receiver must be added to the indoor unit. Cleanliness 25° 35° 2-way flow Wireless LCD remote controller Remote controller 35° 1 pattern Note: Remote controller cable not included. Cables must be procured locally. Comfort Settable to 5 different levels between 0° and 60° 0° Auto-swing between 0° and 35° 4-way flow Quiet (Wired Remote Controller) 60° 0° Multi-Flow System Navigation Remote Controller Heat pump 0° Auto-swing between 0° and 60° Note: This angle above is provided as a guide. It may differ depending on the installation site. Note: Remote controller cable not included. Cables must be procured locally. Cooling only Draft prevention setting 5-levels air direction setting 0° 60° 600 mm BRC1C61 Airfow angle can be adjusted in accordance with room conditions. Auto-swing 700 mm Wired LCD remote controller 0° 575 mm FFQ25/35/50/60BV1B Option Accessory required for indoor unit. Horizontal flow *5 *5 60B Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Hot start (after defrost) Uncomfortable cold air draft is avoided when heating operation starts or when switching to heat after defrosting. Switchable fan speed: High/Low High setting provides maximum reach while low setting minimises drafts. Drain pump is equipped as standard accessory with 750 mm lift. 750 mm 14 CEILING SUSPENDED TYPE Comfortable airflow travels throughout the room New 140 model provides greater capacity for large spaces Cooling only / Heat pump FHQ35BVV1B FHQ50/60BVV1V FHQ60BVV1G FHQ71/100/125BVV1B FHQ140CAVEB(A) The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation. FHQ71BV Flap neatly closes when not in use. NEW FHQ140CA Fresh white colour. Installable on ceilings 4.3 m high Option Accessory required for indoor unit. Wired LCD remote controller Connection to a centralised control system is available, without option. Note: Remote controller cable not included. Cables must be procured locally. Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Navigation Remote Controller (Wired Remote Controller) BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. Comfortable Wireless LCD remote controller A signal receiver must be added to the indoor unit. Cooling only 35-125BV BRC7EA66 Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room BRC7GA56 140CA 35-125BV BRC7EA63W Heat pump BRC7GA53 140CA 35-125BV Louver manually adjusts for straight or wide angle airflow 140CA Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set. Installable on ceilings 3.5 m high (FHQ35-125BV) Features 15 *7 *8 *8 *8 *8 *9 • • *10 *7 *12 • • • • *6 *7 *7 • • • • • • • • • • • • • • • --- *5When RXS35 is used, applicable when outdoor temperature is from 10 to 46°CDB *1FHQ35-125BV: 2 step, FHQ140CA: 3 step *2Installable on max. 3.5 m (35-125BV), 4.3 m (140CA) high ceiling *6Applicable to RZR outdoor units *8Applicable when BRC1E62 is used *3Applicable when wired remote controller is used *7Applicable to RZQ outdoor units *9Applicable when BRC1C61 is used *4Applicable to RKS outdoor units when outdoor temperature is from 10 to 46°CDB *10Option Anti corrosion treated heat exchangers *5 *6 Fresh air intake kit • *11 DIII-NET communication standard *3 *6 Options Others Interlock control *2 *10 Central remote control *9 Auto-cooling/heating change-over Control by 2 remote controllers Group control by 1 remote controller External command control *8 Auto-restart *8 Control features Self-diagnosis function *8 Emergency operation *8 Low gas pressure detection On/Off timer *6 Filter sign Weekly schedule timer Off timer (programmed) *4 Long-life filter Setpoint range set --- Pre charged for up to 30 m Pre charged for up to 10 m Setpoint auto reset *3 Drain pump mechanism Night quiet operation *2 Anti-bacterial air filter Year-round cooling applicable • • Hot start (after defrost) *1 Programme "Dry" Switchable fan speed *1 Two selectable temperature-sensors • • • --- High ceiling application Heat pump Draft prevention function (heating) Auto swing Cooling only Work & Servicing Two selectable temperature-sensors *13 *13 *14 --- --- *14 *11Applicable to RKS outdoor units *12Applicable to RXS outdoor units *13FHQ140CA only *14For the outdoor units Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Switchable fan speed: High/Low (FHQ35-125BV) dB(A) Indoor unit High Middle Low 35BVV1B 50/60BVV1V 60BVV1G 71BVV1B 100BVV1B 125BVV1B 140CA 37 39 39 39 42 44 46 ------------- 32 35 35 35 37 39 38 42 Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Uses quiet stream fan and other quiet technologies. (FHQ35-125BV) Turbulent flow is reduced Straightening plate Quiet stream fan Installation flexibility for freedom of design Flexible installation The unit fits more snugly into tight spaces. 30 mm 30 mm or more or more *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case. 3 fan speeds: High/Middle/Low BRC1C61 Remote controller Cleanliness Sound operation has been reduced on the exposed ceiling suspended type unit. High/Middle/Low : 46/42/38 dB(A) Sophisticated design Comfort Quiet operation Drain pump kit (option) can be easily incorporated Drain pipe connection can be done inside the unit. refrigerant and drain pipe outlets are at the same opening. 600 mm Drain pump kit (built inside main unit) All wiring and internal servicing can be done from under the unit Pipes more easily rigged Low gas pressure detection Easy maintenance Long-life filter lasts about 1 year* * For dust concentration of 0.15 mg/m3 Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign). Non-flocking flap Condensation does not easily form on and dirt does not cling to non-flocking flap. Non-flocking flap It is easy to clean. Easy-clean, flat surfaces Oil resistant grille Programme "Dry" Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments. Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments. 16 CEILING MOUNTED SLIM DUCT TYPE CEILING MOUNTED BUILT-IN TYPE Suitable for tight ceiling spaces spaces. Clever and compact mini ducted unit provides comfort and flexibility Option Heat pump FDXS25/35/50/60CVMA Option Heat pump Accessory required for indoor unit Wired LCD remote controller FBQ50/60/71BV1A Wired LCD remote controller Accessory required for indoor unit BRC1C61 BRC944B2 Note: 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary. Navigation Remote Controller (Wired Remote Controller) Standard BRC1E62 Wireless LCD remote controller A signal receiver must be added to the indoor unit. Heat pump ARC433B69 Wireless LCD remote controller Signal receiver unit (Separate type) A signal receiver must be added to the indoor unit. Wireless remote controller and signal receiver unit are equipped as a set. Heat pump Signal receiver unit (Separate type) Note: Refer to Engineering data for airflow and External static pressure characteristics. Wireless remote controller and signal receiver unit are sold as a set. Smooth Finish The only visible sign of these unobtrusive units is their discharge grilles. They fit completely inside the ceiling to maintain the original decor of a room. Each unit comes with its own wireless remote controller. Slim Profile All units share the same low height of just 200 mm. This means it is now possible to install a unit inside a shallow ceiling cavity with a height of just 240 mm. Comfortable Comfortable To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. At the same time, different types of architectural space can be kept comfortable. L-shaped space Indoor unit High Low 25C 35 35 37 38 31 31 33 34 50C 60C Long space dB(A) Indoor unit High Low 50B 60B 71B 33 34 34 29 30 30 The height of the unit is a mere 300 mm. It can be installed in a narrow 30 mm 300 ceiling space. (when access panel is used.) Access panel Provided with condensate drain pump, waking drain piping easier in 250 mm awkward spaces. Access panel External static pressure can be set depending on duct length, presence of high-efficiency filter, and other installation conditions. Compact External static pressure pattern Compact design of built-in type helps blend with interior decor. Height reduced to allow installation in confined spaces. Features (Pa) Indoor unit High Standard Low 50B–71B 88 49 20 External static pressure is set to standard when the unit is shipped from the factory. Features • • • • • • • Anti corrosion treated heat exchangers • Interlock control External command control • Others Central remote control Group control by 1 remote controller *5 Control by 2 remote controllers • Auto-cooling/heating change-over • Auto-restart *4 Self-diagnosis function *3 Control features Filter sign *3 *3Applicable when BRC1E62 is used *4Applicable when BRC1C61 is used Pre charged for up to 10 m *3 Drain pump mechanism *3 Work & Servicing Mould-proof drain pan *2 On/Off timer • Off timer (programmed) *1 *1Applicable when wired remote controller is used *2Applicable when outdoor temperature is from 10 to 46°CDB Cleanliness Weekly schedule timer • Setpoint range set • Setpoint auto reset Heat pump Year-round cooling applicable *2 Hot start (after defrost) • Remote controller Two selectable temperature-sensors • Programme "Dry" • Anti corrosion treated heat exchangers • Comfort Switchable fan speed (2 step) *2 Central remote control • Auto-cooling/heating change-over *1 Auto-restart Hot start (after defrost) • Others Control features Self-diagnosis function Programme "Dry" • Mould-proof air filter Auto airflow rate • Year-round cooling applicable Switchable fan speed (2 step) • *1Applicable when outdoor temperature is from 10 to 46°CDB *2For the outdoor units Pre charged for up to 10 m Cleanliness Work & Servicing Comfort 17 U-shaped space dB(A) 35C Heat pump Work & Servicing Flexibly adapts to shop interiors Quiet operation Quiet operation BRC4C62 *5 *5For the outdoor units 18 DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Enhance comfort using cleverly placed ducts Increased freedom of design thanks to variable control over external static pressure Cooling only / Heat pump Comfort airflow achieved in accordance with conditions such as duct length. FBQ50/60DV1V FBQ60/71/100/125/140DV1 When testing standard integrated ceiling units that employ duct work, much time used to be required to adjust airflow to the right level. Thanks to the ability provided by Daikin to automatically perform this troublesome adjustment using a remote controller, this step is now quick and easy. (Adjust by H tap .) Easier connection with the centralised control system Freely control external static pressure 200 Pa Set to low static pressure when ducts are short. Use remote controller to adjust airflow 1. Adjust to approximately ±10% of the rated H tap airflow. 2. Once actual operation has begun, adjustment of the rated airflow is not possible. Using a DC fan motor, the external static pressure can be controlled within a range of 50 Pa to 200 Pa. 50 Pa Reduced installation time Quiet operation Set to high static pressure for advanced needs such as when using dampers and long ducts. dB(A) 50/60/71D 100D 125/140D 37 32 38 33 40 36 High Low Option Thin, lightweight indoor unit makes delivery and installation easy. Accessory required for indoor unit. Wired LCD remote controller BRC1C61 Note: Remote controller cable not included. Cables must be procured locally. Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Easy maintenance Maintenance is easy because the drain pan can be removed. With a height of only 300 mm, installation is possible even in buildings with narrow ceiling spaces. Navigation Remote Controller (Wired Remote Controller) Clean Silver ion anti-bacterial drain pan BRC1E62 300mm Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Note: Remote controller cable not included. Cables must be procured locally. Indoor unit Wireless LCD remote controller A signal receiver must be added to the indoor unit. BRC4C64 BRC4C62 Cooling only Heat pump 50/60/71D Height (mm) Width (mm) Depth (mm) Machine weight (kg) 100D 125D 140D 300 1,000 Comfortable 1,400 700 36 Two selectable temperature-sensors 46 Drain pump is equipped as standard accessory with 700 mm lift. Signal receiver unit (Separate type) *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. 700 mm Wireless remote controller and signal receiver unit are sold as a set. Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. Features *1Applicable when wired remote controller is used *2For the outdoor units *3Applicable when BRC1E62 is used 19 • • • • • • *2 *2 • • • • • • • • • • • • • • • • • • • • • --- Anti corrosion treated heat exchangers High efficiency filter DIII-NET communication standard *5 Option Others Interlock control *5 *2 Central remote control *2 External command control • • *5 Group control by 1 remote controller *5 *4 Control by 2 remote controllers *4 *3 Auto-cooling/heating change-over Anti-bacterial air filter *3 *3 Auto-restart On/Off timer *3 *3 Control features Self-diagnosis function Off timer (programmed) *3 *3 Emergency operation Weekly schedule timer *3 *2 Low gas pressure detection Setpoint range set *2 Filter sign Setpoint auto reset --- Long-life filter Night quiet operation --- *1 Drain pump mechanism Year-round cooling applicable *1 Pre charged for up to 30 m Hot start (after defrost) • • • • Two selectable temperature-sensors Heat pump Programme "Dry" Switchable fan speed (2 step) Cooling only Work & Servicing Cleanliness Silver ion anti-bacterial drain pan Remote controller Comfort *2 *2 Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms. Door-installed ventilation grille Partitioning wall Wall-installed ventilation grille Under-door cutout Ventilates air through the partitioning wall. (See right) Ventilation grille Ventilation grille Under-door cutout Note: The under-door cutout method should be used only when there is a small volume of airflow. *4Applicable when BRC1C61 is used *5Option 20 Floor Standing Type New airflow control for more comfort New comfortable airflow control 1) Left and right directions (by remote controller) Auto swing direction is selectable from 3 patterns to suit the layout of the room. (Applicable when BRC1E62 is used.) Pattern 1 Cooling only / Heat pump Wide swing toward the front Pattern 2 Swing on the left side Pattern 3 Swing on the right side FVQ50/60CVE FVQ71/100/125/140CVEB When installed in the center of a wall. When installed in the corner of a room. 2) Up and down directions (by hand) Independent up-and-down airflow directions facilitate even room temperature and help save energy. BRC1E62 can be incorporated into the main unit. Freely select both up and down airflow direction with 8-louver (horizontal blade) operation. Example applications New unit Upper louver (1) Lower interlocking louvers (2) Lower louver (1) Each set of louvers to can be independently adjusted. (Manual adjustment) Comfortable fan speed control Option Accessory required for indoor unit. Wired LCD remote controller Switchable fan speed: High/Middle/Low and Auto BRC1C61 ("Auto" is applicable when BRC1E62 is used.) Note: Remote controller cable not included. Cables must be procured locally. (Wired Remote Controller) High fan speed mode (applicable for FVQ50-100) BRC1E62 To carry airflow to the far side of the room, airflow rate can be increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.) Note: Remote controller cable not included. Cables must be procured locally. Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Features *1 *1 *1 *1 *5 21 *4 *4 *4 Interlock control *4 *4For the outdoor units *5Applicable when BRC1C61 is used • • • • Others DIII-NET communication standard Anti corrosion treated heat exchangers • • *4 Central remote control *3 *1Applicable when BRC1E62 is used *2Applicable for FVQ50-100 *3Applicable when wired remote controller is used • • External command control *5 Auto-cooling/heating change-over Control by 2 remote controllers Group control by 1 remote controller *1 Auto-restart *1 Control features Self-diagnosis function *1 Emergency operation On/Off timer *1 Filter sign Off timer (programmed) *4 Low gas pressure detection Weekly schedule timer --- Long-life filter Setpoint range set --- Pre charged for up to 30 m Setpoint auto reset *3 Anti-bacterial air filter Night quiet operation *2 Year-round cooling applicable *1 • • Hot start (after defrost) *2 Two selectable temperature-sensors *1 Programme "Dry" High fan speed mode Switchable fan speed (3 step) • • • • • • Auto airflow rate Heat pump Independent up-and-down airflow Auto swing Cooling only Work & Servicing Cleanliness • • • • • • • • • • • • • • • • • • • --- Quiet operation dB(A) Indoor unit 50/60/71C 100C 125C 140C High 43 50 51 53 Middle 41 47 48 51 Low 38 44 46 48 Auto airflow rate is selectable. Navigation Remote Controller Remote controller Turning louvers and upward and leaving and horizontal will reduce uneven room temperature. Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature. Comfort When cooling Upper interlocking louvers (4) *4 *4 Energy saving A DC fan motor improves efficiency. Quick and easy installation and maintenance Lightweight indoor unit Enables smooth transport and installation of the indoor unit. Indoor unit 50/60/71C Weight 39 100C 125C (kg) 140C 47 Long-life filter lasts about 1year * maintenance not required * For dust concentration of 0.15 mg/ m3 Employs a safety lock function of suction grill. The grill will not open even upon impact. Easier connection with the centralised control system. 22 OUTDOOR UNIT Technology for energy efficiency Compact Outdoor unit The high efficiency compressor to achieve a high COP 1 Compressor equiped with Reluctance DC motor Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. RZQ50KBV1V/KBV4A RZQ60KBV1V/KBV4A RZQ71KCV4A RZR100LUY1 RZR125LVVM/LUY1 RZR140LVVM/LUY1 RZR100LVVM Easy installation and maintenance Pre charged for up to 30 metres 4-direction piping offers greater layout freedom If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. (not applicable for RZR50-71) Allowed refrigerant piping length and level difference RZR50-140LU/LV RZQ100-140KC RZQ50/60KB RZQ100-140HA RZQ71KC Pre charged1 Max. length (Refrigerant recovery function) A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified. 75 m 50 m (Equivalent length (Equivalent length 70m) 90m) Max. level difference (RZR50-71 only) Facilitates pump down 30 m 30 m Note : 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Cooling only Heat pump Rated2 Night Quiet Mode RZQ50/60KB 48 44 RZQ71KC 48 44 RZR100LU/LV RZQ100KC/HA 49 45 RZR125LU/LV RZQ125KC/HA 50 45 RZR140LU/LV RZQ140KC/HA 50 46 8 hours RZR71LV Note 23 :1 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 2 Value when cooling. Value will differ when heating. Load (%) Operation Sound3 (dB(A)) 50 RZR50/60LU/LV 0 49 0 60 Small load Low capacity 90 120 Large load High capacity RZR50/60LU/LV, RZR71/100LVVM RZQ50/60KB, RZQ71KC 2 Construction Swing bushing Refrigerant gas >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. Non-treated fin Aluminium Anti corrosion treated heat exchangers Hydrophilic film Aluminium Corrosion resistant acrylic resin Sine wave DC inverter RZR125/140LVVM, RZR100/125/140LUY1 RZQ100/125/140KC, RZQ100/125/140HA Suction >> Swing compressor >> The structural scroll Energy savings is realised, eliminating the friction and the leakage of refrigerant gas. Sucked gas is compressed in the scrolling part before the heated motor, so that the machine compress Discharge the non-expanded gas, resulting in high efficiency compression. Piston by incorporated blade and roller. Smooth Air Inlet Bell Mouth and Aero Spiral Fan (not applicable for RZR50-71) With the bent blade edge Scroll section Motor section Without the bent blade edge These two features work to reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. Demand Control Function The maximum capacity is maintained within a set level of power consumption, which makes it possible to keep comfort and effective demand control. 10 hours 30 Rotational speed (rps) Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. (RZR100-140 and RZQ only) 100 AC motor 3 DC fan motor Efficiency improved in all areas compared to AC motors, especially at low speeds. DC fan motor structure Limitation Power consumption 1 Capacity (%) Peak in outdoor temperature 70 50 Durability Heat exchange fins provided with anti-corrosion treatment The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Conventional DC motor More than 20% 60 Imitating the performance of the swan Low gas pressure detection function 1 80 *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts. Φ550 V-cut propeller fan 2 Reluctance DC motor Reluctance DC Motor 90 Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. As the bottom frame is subject to corrosion, corrosion-proof galvarium steel plate is adopted to enhance the durability. Night time quiet operation function Sound level (dB(A)) Through use of a V-cut propeller fan that imitates the efficiency of the swan, a migratory bird, airflow becomes smooth and loss is reduced. *Pump-down function is available for pre-charged refrigerant amount. Effective gas monitoring reduces the labor required for operation, maintenance, and repairs. Reducing noise will reduce capacity slightly. RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Energy saving The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installatio Separation n piping work. available Long piping length RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A Motor efficiency (%) RZR50LUV1V/LVVM RZR60LUV1V/LVVM RZR71LVVM 3 Rated 45 Quiet mode 8:00 12:00 16:00 20:00 Note : 3In case of RZR100 Quiet mode 0:00 4:00 8:00 8:00 12:00 16:00 * Required for KRP58M51 (Option) 20:00 Time 24 LCD REMOTE CONTROLLER Optional accessory Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. Remote controller options are shown on the page introducing each indoor unit model. Navigation Remote Controller (Wired Remote Controller BRC1E62) Wired LCD remote controller The rubber switch and the oil-resistant plastic casing are adopted for durability. This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller. NEW Wired remote controller has built-in temperature-sensor Easy to read because of large LCD screen. Only 17 mm thick. Can be installed either recessed or exposed. (Applies to wired remote controllers (BRC1C61/1E62)) Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.) Facilitates maintenance and repair All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting. BRC1C61 Setting contents: High ceiling use, air direction, filter type, address Clear Display Dot matrix display LCD wireless remote controller Backlight display A combination of fine dots enables various icons. Large text display is easy to see. The wireless remote controller is supplied in a set with a signal receiver. Signal receiver unit is contained inside decoration panel or indoor unit Shape of signal receiver unit differs according to the indoor unit. BRC7F633F Energy saving NEW Setpoint auto reset Restaurant sample Temperature is set to 27ºC Wireless remote controller NEW - Even if the set temperature is changed, it returns to the preset temperature after apreset period of time. - Period selectable from 30min/60min/90min/120min. Restaurant opened for centralised control (group control address is set automatically). Full tables at lunchtime Then is lowered to 24ºC for crowded room After 30 minutes* Automatically returns to preset temperature (27ºC) Setpoint range set - Saves energy by limiting the min. and max. set temperature. - Avoids excessive heating or cooling. - This function is convenient when the remote controller is installed at a place where any number of people may operate it. Signal receiver unit (For ceiling mounted cassette type) Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type. CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE Airflow / swing display - 5 actions per day can be scheduled for each day of the week. - The holiday function will disable schedule timer for the days that have been set as holiday. NEW - 3 independent schedules can be set. Easily adaptable to large-scale, high-function, centralised remote control systems. Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy. BRC7E530W BRC7EA66 BRC7EA63W 140CA BRC7GA56 BRC7GA53 ----- ARC433B69 (standard accessory) ----- BRC4C62 BRC4C64 BRC4C62 LCD panel shows operating status in letters, numbers, and motion. Convenience Weekly schedule Heat pump BRC7F632F BRC7E531W DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE - Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. - Period can be preset from 30 to 180 minutes in10-minute increments. Cooling only BRC7F633F 35-125BV COMPACT MULTI FLOW TYPE CEILING MOUNTED BUILT-IN TYPE Off timer (programmed) SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations. Wireless remote controller for each indoor unit type CEILING MOUNTED SLIM DUCT TYPE *Setting possible for after 30, 60, 90, and 120 minutes. Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction. (Applies to wired remote controller (BRC1E62)) Preset temperature / operation mode display Multilingual display Display is available in 11 languages. Programming time display Self-diagnosis function Displays auto-swing operating status and setting position of air discharge angle. Displays preset room temperature and operating status (fan, dry, cool). Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning. Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish). (e.g. summer, winter, mid-season) 25 26 Simultaneous operation system Simple system provides a diverse assortment LCD of control modes. REMOTE CONTROLLER Wireless remote controller (Basic system) Non-polar, double-core (max. wiring length 500 m) Control by 2 remote controllers Signal receiver unit installed on indoor unit Four new types of Multi series indoor units are now available! Control by 1 wireless remote controller and 1 wired remote controller (See note 2, 3) For control from 2 locations such as in room and control room, exits, etc. Signal receiver unit installed on indoor unit Connects 2 wired remote controllers (See note 1) Branch piping kit Group control For simultaneous control of up to 16 indoor units. Automatic address setting function Automatic address setting function Signal receiver unit installed on 1 indoor unit Control by external command Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. Optional wiring adaptor for electrical appendices is necessary Interlock control with Heat Reclaim Ventilator Interface adapter for SkyAir series (option) is required (See note 4) Interface adapter for SkyAir series (option) is required (See note 4) Heat Reclaim Ventilator Heat Reclaim Ventilator Can be operated simultaneously or independently by remote controller (set by ventilation mode) Can be operated simultaneously by remote controller (set by ventilation mode) Central remote controller (option) Zone link control by centralised control. Central remote controller (option) Heat Reclaim Ventilator Heat Reclaim Ventilator Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Can also be operated independently by remote controller. FHQ60BVV1G X2 FHQ71BVV1B X2 specifications Page 31 specifications Page 33 Branch piping kit Central remote controller (option) Centralised control of up to 64 indoor groups from remote location up to 1 kilometer away. Link by remote controller group control. FCQ60/71LUV1 X2 Optional wiring adaptor for electrical appendices is necessary Central remote controller (option) Centralised remote control Branch piping kit Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking FBQ60/71DV1 X2 specifications Page 34 specifications Page 35 Twin Multi for comfort and economy Lower installation cost than individual pair type Reduced outdoor unit installation space Distributed indoor units enhance comfort Central remote controller DCS302CA61 (Option) Unified on/off controller DST301BA61 (Option) Centralised control, with setting as simple as it is with a standard remote controller, of up to 64 groups (1,024 indoor units) is possible. Centralised control of on/off by group or all at once for up to 256 indoor units. Interface adaptor for SkyAir series Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system. DTA112BA51 (Option) Unified control of weekly schedule for up to 1,024 indoor units. Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time. Necessary for interface adaptor for SkyAir series with the central remote control units shown at above. 27 Piping guideline Schedule timer DCS301BA61 (Option) DCS601C51 (Option) With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways. The interface adaptor for the SkyAir series is optional except for the ceiling mounted cassette type <Round Flow>, ceiling suspended type (140CA only), duct connection middle and high static pressure type, and floor standing type. For example, four indoor units are judiciously spaced in this wide single-floor restaurant to deliver comfortable currents of air to every corner of the room. 2 sets of Twin Multi Note: 1BRC1E62 can connect to BRC1E62 only. 2 It is not possible to use two wireless remote controllers. 3 BRC1E62 cannot connect to wireless remote controller. 4 The ceiling mounted cassette type <Round Flow>, ceiling suspended type (140CA only), duct connection middle and high static pressure type, and floor standing type come standard with an interface adaptor for SkyAir series. Easily adaptable to large-scale, high-function, centralised remote control system. Branch piping kit FVQ60CVE X2 FVQ71CVEB X2 Outdoor unit RZR125/140LVVM RZR125/140LUY1 Max. piping length L0 One-way max. piping length (longest length of liquid piping or gas piping) L0 L1 50 m (In case of L1 L2) Max. branch piping length Max. difference of branch piping length L1 L2 Refrigerant branch piping kit for Twin Multi operation (option) Indoor unit 60 m Indoor unit L2 L1, L2 20 m Max. level difference between indoor units H1 0.5 m Max. level difference between outdoor unit and indoor units H 30 m Page 43 Branch piping Branch piping L1 L2 10 m (In case of L1 L2) KHRP58P216T H1 Control by 1 remote controller Wired remote controller H Control pattern Twin Multi operation L1 Main piping L0 Outdoor unit 28 Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Comfort High-ceiling application Auto-swing Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner. The air flow direction can be fixed at your desited angle by the remote controller. Swing pattern selection (standard, ceiling soiling prevention) Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings. You can freely set 2 air discharge setting by remote controller. (1) Air direction in standard setting (2) Air direction in ceiling soiling prevention setting Draft prevention function (heating) To prevent cold air drafts, automatically adjusts airflow to near horizontal position when heating initially starts or when the thermostat turns off. Independent up-and-down airflow Independently adjust (manually) the eight horizontal blade louvers in both up and down directions to achieve an airflow that reduces uneven room temperature. Switchable fan speed High setting provides maximum reach while low setting minimises drafts. Auto airflow rate Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature. High fan speed mode You can increase fan speed approximately 10% higher than the "high" setting. Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply. Two selectable temperature-sensors Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level. Use the temperature-sensor in the indoor unit when controlling air conditioning from another room. Note: Wireless remote controllers have no temperature-sensor. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Work and Servicing Drain pump mechanism Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. Pre charged for up to 30 metres If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. *Applicable to RZR/RZQ series. RKS/RXS series: 10 m Cold air flow is avoided when heating operation starts or when switching to heat after defrosting. Year-round cooling applicable Efficient cooling even in winter when the indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. Maintenance is not required for one year (two years when a ceiling mounted cassette type is used). Filter sign The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room. Night quiet operation The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. Auto cool/heat change-over (Heat pump only) Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly. Setpoint auto reset Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. Off timer (programmed) Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. Setpoint range set Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling. Control by 2 remote controllers Using 2 remote controllers you can operate the equipment locally or from a remote location. Note: When a wireless remote controller is used, remote control by two remote controllers is not possible. Group control by 1 remote controller Remote Controller On/Off timer Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses. High-efficiency filter unit Two types are available: 65% and 90% colorimetry. Ultra long-life filter Requires no maintenance for about 4 years* (10,000h) in stores and offices. Cleanliness Anti-bacterial air filter Mould-proof air filter Sanitary filter has mould-resistant treatment. 29 Silver ion anti-bacterial drain pan Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Mould-proof drain pan Mould-proof drain pan prevents growth of mould in highly humid conditions. If there is a malfunction elsewhere in the system, the fan or compressor can still be operated. Self diagnosis function The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates. External command control Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. *Required for KRP58M51 (Option) Central remote control Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away. Interlock control Enables interlocking control with external equipment such as Heat Reclaim Ventilator. DIII-NET communication standard Standardly equipped interface enables connection to centralised control system without need of an adaptor. Options *For dust concentration of 0.15 mg/m3 The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it. Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly. You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.) Weekly schedule timer Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature. Low gas pressure detection Control features Applicable for wall mounted type Programme "Dry" Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. Emergency operation Long-life filter Auto-restart Hot start (after defrost) Ceiling soiling prevention function Fresh-air intake kit You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending. Others Anti corrosion treated heat exchangers To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out. 30 SPECIFICATIONS CEILING MOUNTED CASSETTE TYPE Model Name Power supply Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Indoor unit 100 125 100 125 RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1 Cooling1 kW 5.0 (2.3-5.6) 5.8 (2.6-6.3) 1.30 3.84 1.57 3.70 1 Phase, 220–240 V, 50 Hz 10.0 7.1 (5.0-11.2) (3.2-8.0) 1.99 3.57 2.78 3.60 Unit Decoration panel Sound level (H/L)3 Unit Dimensions (HXWXD) Decoration panel Machine weight Unit Decoration panel Certified Operation range Cooling Colour Type Compressor Motor output Refrigerant charge (R-410A) Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Liquid (Flare) Piping connections Gas (Flare) Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference m3/min cfm dB(A) mm 21/13.5 741/477 35/28 256X840X840 mm kg kg 21 32/20 1,130/706 43/32 kg dB(A) dB(A) mm kg °CDB mm mm 14.0 (6.2-15.4) 3.68 3.40 ---------- 4.91 2.85 2.78 3.60 Fresh white 32/20 33/22.5 1,130/706 1,165/794 44/34 44/36 43/32 298X840X840 50X950X950 24 5.5 °CWB kW 12.5 (5.7-14.0) 3 Phase, 380–415 V, 50 Hz 12.5 10.0 14.0 (5.7-14.0) (5.0-11.2) (6.2-15.4) 3.68 3.40 4.91 2.85 Hermetically sealed swing type 1.35 1.76 3.15 (Charged for 30 m) 2.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48 44 595X845X300 43 49 50 49 50 45 1,170X900X320 92 97 46 97 21 to 46 o/ 9.5 o/ 15.9 mm mm m m VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping Heat insulation FFQ60BV1B Outdoor unit RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG Power supply Outdoor unit Power consumption Cooling1 35 1 Phase, 220–240 V, 50 Hz kW kW W/W COP Unit Decoration panel m3/min Airflow rate (H/L) 2.5 (1.2-3.0) 3.4 (1.2-3.7) 4.7 (1.7-5.6) 5.8 (1.7-6.0) 0.73 3.42 1.10 3.09 1.62 2.90 2.07 2.80 12/8 423/282 36/27 15/10 529/353 41/32 ---------White Colour cfm Outdoor unit 2.7 (Charged for 30 m) 46 FFQ50BV1B 3.1 1.6 (Charged for 30 m) 45 990X940X320 78 FFQ35BV1B 33/22.5 1,165/794 44/34 44/36 Hermetically sealed scroll type 1.8 2.4 3.1 2.4 2.03 60 FFQ25BV1B Indoor unit 14 to 25 Ivory white 1.12 50 Indoor unit Cooling capacity1 Rated (Min. - Max.) 25 Cooling only Model Name 140 Outdoor unit kW Sound level3 140 FCQ50LUV1V FCQ60LUV1V FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 W/W Drain 71 Indoor unit Airflow rate (H/L) Outdoor unit 60 Outdoor unit Colour COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE Cooling only 50 Sound level (H/L)2 Dimensions Unit (HXWXD) Decoration panel Machine weight Unit Decoration panel Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-410A) Sound level2 Dimensions (HXWXD) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation dB(A) mm mm kg kg °CWB 9/6.5 317/229 29.5/24.5 286X575X575 55X700X700 17.5 2.7 14 to 23 Ivory white Hermetically sealed swing type kW 0.6 1.0 (Charged for 10 m) kg dB(A) mm kg °CDB mm mm mm mm m m 10/6.5 353/229 32/25 46 1.1 1.5 (Charged for 10 m) 47 550X765X285 34 49 735X825X300 47 10 to 46 o/ 6.4 o/ 9.5 o/ 12.7 VP20 (I.D o/ 20XO.D o/ 26) o/ 18.0 (Hole) 20 15 30 20 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Twin Multi Model Name Power supply Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Indoor unit 125 140 125 140 Indoor unit FCQ60LUV1x2 FCQ71LUV1x2 FCQ60LUV1x2 FCQ71LUV1x2 Outdoor unit RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 Outdoor unit kW Cooling1 kW W/W Colour Sound level (H/L)3 Unit Dimensions (HXWXD) Decoration panel Machine weight Unit Decoration panel Certified Operation range Cooling Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound level3 Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 14.0 (6.2-15.4) 12.5 (5.7-14.0) 14.0 (6.2-15.4) 3.68 3.40 4.91 2.85 3.68 3.40 4.91 2.85 ---------m /min cfm dB(A) mm mm kg kg kW kg dB(A) dB(A) mm kg °CDB mm mm mm mm m m 3.1 3.7 (Charged for 30 m) 3.15 (Charged for 30 m) 50 45 46 45 1,170X900X320 97 21 to 46 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 31 Indoor unit Power supply Outdoor unit 46 FHQ35BVV1B Outdoor unit Power consumption Cooling COP Colour Indoor Airflow rate (H/L) unit 14 to 25 Ivory white Hermetically sealed scroll type 3.1 2.4 2.4 Model Name Cooling capacity1 Rated (Min. - Max.) Fresh white 21/13.5 741/477 35/28 256X840X840 50X950X950 21 5.5 3 Cooling only 35 12.5 (5.7-14.0) °CWB CEILING SUSPENDED TYPE 3 Phase, 380–415 V, 50 Hz Unit Decoration panel Airflow rate (H/L) Outdoor unit 1 Phase, 220–240 V, 50 Hz RKS35AVMG kW 1 Sound level (H/L)2 Dimensions (HXWXD) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-410A) Sound level2 Dimensions (HXWXD) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW W/W m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 1 Phase, 220–240 V, 50 Hz 3.4 (1.2-3.7) 1.05 3.24 White 13/10 458/353 37/32 195X960X680 24 14 to 23 Ivory white Hermetically sealed swing type 0.6 1.0 (Charged for 10 m) 47 550X765X285 34 10 to 46 o/ 6.4 o/ 9.5 VP20 (I.D o/ 20XO.D o/ 26) o/ 18.0 (Hole) 20 15 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 32 SPECIFICATIONS CEILING SUSPENDED TYPE Model Name Indoor unit Power supply Outdoor unit kW Cooling1 Power consumption COP Colour Indoor Airflow rate (H/M/L) unit Sound level (H/M/L)3 Outdoor unit Dimensions (HXWXD) Machine weight Certified operation range Colour Compressor Type Refrigerant charge (R-410A) Motor output Refrigerant charge (R-410A) 50 60 FHQ50BVV1V FHQ60BVV1V 71 100 100 140 125 125 kW W/W 5.0 (2.3-5.6) 1.60 3.13 m /min cfm dB(A) mm kg °CWB 3 kW kg Sound level3 Cooling dB(A) Night quiet mode dB(A) mm Dimensions (HXWXD) kg Machine weight Certified operation range °CDB mm Piping Liquid (Flare) connections mm Gas (Flare) mm Drain Indoor unit mm Outdoor unit m Max. interunit piping length m Max. installation level difference Heat insulation FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ140CAVEB FHQ100BVV1B FHQ125BVV1B 1.12 5.8 (2.6-6.3) 1.99 2.92 1 Phase, 220–240 V, 50 Hz 7.1 10.0 (3.2-8.0) (5.0-11.2) 2.50 2.84 White 12.5 (5.7-14.0) 3.51 2.85 13.3 (6.2-15.4) 3 Phase, 380–415 V, 50 Hz 10.0 12.5 (5.0-11.2) (5.7-14.0) 4.55 2.75 4.68 3.51 4.55 2.84 2.85 2.75 Fresh white White 17/-/14 24/-/20 30/-/25 34/29/24 24/-/20 30/-/25 600/-/494 847/-/706 1,059/-/883 1,200/1,024/847 847/-/706 1,059/-/883 39/-/35 42/-/37 44/-/39 42/-/37 44/-/39 46/42/38 195X1,160X680 195X1,400X680 195X1,590X680 235X1,590X690 195X1,400X680 195X1,590X680 38 35 27 32 32 35 14 to 25 Ivory white Hermetically sealed swing type Hermetically sealed scroll type 1.76 1.35 2.6 2.03 3.1 2.1 2.6 1.6 (Charged for 30 m) 2.7 (Charged for 30 m) 3.15 (Charged for 30 m) 48 44 595X845X300 43 49 50 45 990X940X320 78 21 to 46 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping 97 2.7 3.7 (Charged for 30 m) (Charged for 30 m) 49 46 1,170X900X320 92 Indoor unit Outdoor unit Power supply Cooling capacity1,2 Rated (Min. - Max.) Outdoor unit Cooling1 Power consumption COP Colour Indoor Airflow rate (H/L) unit Sound level (H/L)3 Dimensions (HXWXD) Machine weight Certified operation range Outdoor unit Colour Type Compressor Refrigerant charge (R-410A) Motor output Refrigerant charge (R-410A) Sound level3 Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified operation range Piping connections Liquid (Flare) Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation Model Name 50 kW kW W/W 140 125 140 FHQ60BVV1Gx2 FHQ71BVV1Bx2 RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 5.32 2.50 2.4 White 17/14 600/494 39/35 195X1,160X680 27 14 to 25 Ivory white Hermetically sealed scroll type 2.6 3.1 m3/min cfm dB(A) mm kg °CWB kW 3.15 (Charged for 30 m) kg dB(A) dB(A) mm kg °CDB mm mm mm mm m m 4.55 2.75 5.32 2.50 unit 5.0 (2.3-5.6) 5.8 (2.6-6.3) 7.1 (3.2-8.0) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4) Cooling1 kW W/W 1.39 3.60 1.63 3.56 2.22 3.20 2.82 3.55 3.73 3.35 ---------- 4.71 2.97 Cooling m3/min cfm Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 140 32/23 1,130/812 18/15 635/530 2.82 3.55 39/28 1,377/988 4.71 2.97 3.73 3.35 32/23 1,130/812 39/28 1,377/988 38/33 40/36 50-200 3 Pa dB(A) dB(A) mm kg 3 Phase, 380–415 V, 50 Hz 10.0 12.5 14.0 (5.0-11.2) (5.7-14.0) (6.2-15.4) 37/32 38/33 40/36 ---------- 5 300X1,000X700 36 300X1,400X700 46 14 to 25 Ivory white 1.12 Hermetically sealed swing type 1.76 1.35 2.03 Hermetically sealed scroll type 2.9 1.8 2.4 2.4 2.9 1.6 (Charged for 30 m) 2.7 (Charged for 30 m) 3.15 (Charged for 30 m) 2.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48 44 595X845X300 43 49 50 49 50 45 990X940X320 78 45 1,170X900X320 92 46 97 21 to 46 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping °CDB mm mm mm mm m m 46 97 125 140 125 140 FBQ60DV1x2 FBQ71DV1x2 FBQ60DV1x2 FBQ71DV1x2 Outdoor unit RZR125LVVM RZR140LVVM RZR125LUY1 RZR140LUY1 46 Outdoor unit 1 Phase, 220–240 V, 50 Hz Indoor unit Outdoor unit Fan Airflow rate (H/L) 1 Phase, 220–240 V, 50 Hz 12.5 (5.7-14.0) 14.0 (6.2-15.4) 12.5 (5.7-14.0) 14.0 (6.2-15.4) Cooling1 kW W/W 3.73 3.35 4.71 2.97 3.73 3.35 4.71 2.97 Cooling m3/min cfm Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Piping Liquid (Flare) connections Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation ---------18/15 635/530 50-200 3 Pa Sound level4 Cooling (H/L) dB(A) Air filter mm Dimensions (HXWXD) kg Machine weight Certified Operation range Cooling °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) Sound level4 3 Phase, 380–415 V, 50 Hz kW External static pressure (Middle-High) 2.9 45 125 Indoor unit Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Colour Indoor 1,170X900X320 97 21 to 46 o/ 9.5 o/ 15.9 VP20 (I.Do/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping 1 Phase, 220–240 V, 50 Hz 1 Phase, 220–240 V, 50 Hz Sound level4 Cooling (H/L) dB(A) Air filter mm Dimensions (HXWXD) kg Machine weight Certified Operation range Cooling °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) Power supply 3.7 (Charged for 30 m) 46 Airflow rate (H/L) Model Name 50 45 100 Twin Multi 3 Phase, 380–415 V, 50 Hz 12.5 13.3 (5.7-14.0) (6.2-15.4) 4.55 2.75 140 kW Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Piping Liquid (Flare) connections Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation FHQ71BVV1Bx2 Cooling only 125 RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1 Sound level4 125 100 Outdoor unit External static pressure (Middle-High) Outdoor unit 71 FBQ50DV1V FBQ60DV1V FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 Indoor unit Outdoor unit Fan unit 60 Indoor unit Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Colour Indoor 97 FHQ60BVV1Gx2 1 Phase, 220–240 V, 50 Hz 12.5 13.3 (5.7-14.0) (6.2-15.4) Power supply 45 Twin Multi Model Name 50 RZR50LUV1V RZR60LUV1V RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 Outdoor unit Cooling capacity1,2 Rated (Min. - Max.) DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Cooling only dB(A) dB(A) mm kg °CDB mm mm mm mm m m 37/32 ---------- 5 300X1,000X700 36 14 to 25 Ivory white Hermetically sealed scroll type 2.4 2.9 2.4 3.15 (Charged for 30 m) 50 45 2.9 3.7 (Charged for 30 m) 50 45 46 46 1,170X900X320 97 21 to 46 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Initial setting is standard. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more. 33 34 SPECIFICATIONS FLOOR STANDING TYPE CEILING MOUNTED CASSETTE TYPE Cooling only 50 Model Name Power supply Outdoor unit 100 125 140 100 125 Outdoor unit RZR50LVVM RZR60LVVM RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR100LUY1 RZR125LUY1 RZR140LUY1 1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz kW Airflow rate (H/M/L) Cooling1 kW W/W Cooling m3/min cfm dB(A) mm kg Sound level3 Cooling (H/M/L) Dimensions (HXWXD) Machine weight Certified Operation range Cooling °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) Sound level3 Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Piping Liquid (Flare) connections Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation dB(A) dB(A) mm kg 5.0 (2.3-5,6) 1.27 3.94 1.12 6.0 (2.6-6.3) 1.84 3.26 7.1 (3.2-8.0) 2.58 2.75 3 Phase, 380–415 V, 50 Hz 12.5 13.5 10.0 12.5 13.5 (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) 5.40 5.40 4.39 3.28 4.39 2.50 2.50 2.85 3.05 2.85 Fresh white 28/25/22 28/26/24 30/28/26 28/25/22 28/26/24 30/28/26 18/16/14 988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918 635/565/494 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48 1,850X600X270 1,850X600X350 39 47 14 to 25 Ivory white Hermetically sealed scroll type Hermetically sealed swing type 3.1 2.3 2.8 3.4 1.35 1.76 2.03 2.4 10.0 (5.0-11.2) 3.28 3.05 2.7 (Charged for 30 m) 49 45 990X940X320 78 1.6 (Charged for 30 m) 48 44 595X845X300 43 °CDB mm mm mm mm m m 3.15 (Charged for 30 m) 50 46 97 2.7 (Charged for 30 m) 49 45 1,170X900X320 92 21 to 46 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping Indoor unit Outdoor unit Power supply Outdoor unit Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Colour Indoor unit Outdoor unit Fan kW Cooling1 Airflow rate (H/M/L) Cooling kW W/W Sound Cooling Night quiet mode Dimensions (HXWXD) Machine weight Certified Operation range Cooling Piping Liquid (Flare) connections Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 140 125 140 FVQ71CVEBx2 FVQ60CVEx2 FVQ71CVEBx2 dB(A) dB(A) mm kg °CDB mm mm mm mm m m RZR125LUY1 1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz 12.5 13.5 (5.7-14.0) (6.2-15.4) 5.40 4.39 2.50 2.85 RZR140LUY1 3 Phase, 380–415 V, 50 Hz 12.5 13.5 (5.7-14.0) (6.2-15.4) 5.40 4.39 2.50 2.85 Fresh white 18/16/14 635/565/494 43/41/38 1,850X600X270 39 14 to 25 Ivory white Hermetically sealed scroll type 3.1 2.8 m3/min cfm dB(A) mm kg Sound level3 Cooling (H/M/L) Dimensions (HXWXD) Machine weight Certified Operation range Cooling °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) level3 125 RZR140LVVM 2.4 3.15 (Charged for 30 m) Cooling/Heating3 Night quiet mode Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 3.4 45 1,170X900X320 97 21 to 46 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 (Equivalent length 70) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 46 1 Phase, 220–240 V, 50 Hz 5.0 5.8 (2.5-5.6) (2.9-6.0) 140 100 125 140 7.1 (3.2-8.0) 1 Phase, 240 V, 50 Hz 10.0 12.5 (5.0-11.2) (5.7-14.0) 13.6 (6.2-15.4) 3 Phase, 415 V, 50 Hz 13.6 10.0 12.5 (6.2-15.4) (5.0-11.2) (5.7-14.0) 16.0 (6.2-18.0) 11.2 (5.1-12.8) kW 6.0 (3.5-7.0) 7.0 (3.5-8.0) 8.0 (3.5-9.0) 11.2 (5.1-12.8) kW kW W/W W/W 1.27 1.41 3.93 4.26 1.51 1.74 3.84 4.03 1.99 2.10 3.57 3.81 2.94 3.03 3.40 3.70 m3/min cfm dB(A) mm mm kg kg °CWB °CDB kW kg dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m 21/13.5 741/477 35/28 256X840X840 32/20 1,130/706 43/32 21 1.3 Hermetically sealed swing type 1.6 2.75 (Charged for 30 m) 48/50 44 X 770 900X320 68 4.02 4.54 2.94 3.83 4.80 3.03 3.11 3.00 3.40 3.66 3.33 3.70 ---------Fresh white 33/22.5 32/20 1,130/706 1,165/794 44/34 44/36 43/32 298X840X840 50X950X950 24 5.5 14 to 25 15 to 27 Ivory white Outdoor unit Sound level (H/L)3 Dimensions Unit (HXWXD) Decoration panel Machine Unit weight Decoration panel Cooling Certified Operation range Heating Colour Outdoor Type Compressor unit Motor output Refrigerant charge (R-410A) Sound level Cooling/Heating3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 3.77 3.83 3.32 3.66 4.39 4.80 3.10 3.33 33/22.5 1,165/794 44/34 44/36 1.7 49/51 2.2 4.3 (Charged for 30 m) 50/52 45 X X 1,345 900 320 108 2.9 46 Heat pump 25 35 50 60 FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B RXS25EBVMA RXS35EBVMA RXS50FVMA RXS60FVMA 1 Phase, 220–240 V, 50 Hz Outdoor unit Cooling1 Power consumption Heating2 Cooling COP Heating Unit Indoor Colour unit Decoration panel Airflow rate (H) 16.0 (6.2-18.0) 75 (Equivalent length 90) 30 Both liquid and gas piping m Indoor unit 14.0 (6.0-16.2) Hermetically sealed scroll type 3.1 2.4 3.7 (Charged for 30 m) 49/51 50/52 45 46 X X 1,170 900 320 98 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 1.9 1.7 50 (Equivalent length 70) 30 14.0 (6.0-16.2) COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) 3.7 (Charged for 30 m) 46 Outdoor unit (H/L)3 Unit Decoration panel Unit Machine weight Decoration panel Cooling Certified Operation range Heating Colour Type Compressor Model Name 50 45 kW Cooling1 Heating2 Cooling Heating Colour Unit Decoration panel Fan Airflow rate (H/L) Sound level Dimensions (HXWXD) 125 RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Power consumption Indoor unit 100 Outdoor unit Outdoor unit Heating capacity2 Rated (Min. - Max.) COP 71 FCQ50LUV1V FCQ60LUV1V FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 Sound level FVQ60CVEx2 RZR125LVVM Power supply Cooling capacity1 Rated (Min. - Max.) 60 Indoor unit Motor output Refrigerant charge (R-410A) Twin Multi Model Name Model Name 3.7 (Charged for 30 m) 50 46 97 Heat pump 50 140 FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB Outdoor unit Fan 71 Indoor unit Cooling capacity1,2 Rated (Min. - Max.) Power consumption COP Colour Indoor unit 60 kW 2.5 (1.2-3.0) 3.4 (1.2-3.7) 4.7 (1.7-5.6) 5.8 (1.7-6.0) kW 3.2 (1.2-4.5) 4.0 (1.2-5.0) 5.5 (1.7-7.0) 7.0 (1.7-8.0) kW kW W/W W/W 0.73 0.92 3.42 3.48 1.10 1.20 3.09 3.33 1.62 1.88 2.90 2.93 2.07 2.49 2.80 2.81 12/8 424/282 36/27 15/10 530/353 41/32 ---------White m3/min cfm dB(A) mm mm kg kg °CWB °CDB kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m 9/6.5 318/229 29.5/24.5 10/6.5 353/229 32/25 286X575X575 55X700X700 17.5 2.7 14 to 23 10 to 30 Ivory white Hermetically sealed swing type 1.1 1.5 (Charged for 10 m) 0.6 1.0 (Charged for 10 m) 46/47 47/48 49/49 735X825X300 48 550X765X285 34 10 to 46 -15 to 20 -15 to 18 o/ 6.4 o/ 12.7 o/ 9.5 VP20 (I.D o/ 20XO.D o/ 26) o/ 18.0 (Hole) 30 20 20 15 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 35 36 SPECIFICATIONS CEILING SUSPENDED TYPE CEILING MOUNTED SLIM DUCT TYPE Heat pump Indoor unit Model Name Outdoor unit Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption COP Indoor unit Outdoor unit FHQ35BVV1B RXS35EBVMA kW kW Colour Airflow rate (H/L) Sound level (H/L)3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound level Cooling/Heating3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption 1 Phase, 220–240 V, 50 Hz 3.4 (1.2-3.7) 4.0 (1.2-5.0) Outdoor unit Cooling1 Heating2 Cooling Heating Model Name kW kW W/W W/W 1.05 (0.3-1.23) 1.11 (0.29-1.61) 3.24 (4.00-3.01) 3.60 (4.14-3.11) White 13/10 459/353 37/32 195X960X680 24 14 to 23 10 to 30 Ivory white Hermetically sealed swing type 0.6 1.0 (Charged for 10 m) 47/48 550X765X285 34 10 to 46 -15 to 20 o/ 6.4 o/ 9.5 VP20 (I.D o/ 20XO.D o/ 26) o/ 18.0 (Hole) 20 15 Both liquid and gas piping m3/min cfm dB(A) mm kg °CWB °CDB kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m COP Indoor unit Heat pump 25 35 50 60 Indoor unit FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA Outdoor unit RXS25EBVMA RXS35EBVMA RXS50FAVMA RXS60FVMA 35 Outdoor unit 1 Phase, 220–240 V, 50 Hz kW kW Cooling1 Heating2 Cooling Heating Colour Airflow rate (H/M/L/SL) Fan External static pressure Sound level (H/M/L/SL)3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Outdoor Type Compressor unit Motor output Refrigerant charge (R-410A) 3 Cooling (H/L) Sound level Heating (H/L) Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW W/W W/W 2.4 (1.2-3.0) 3.2 (1.2-4.5) 0.69 (0.3-0.92) 0.91 (0.29-1.49) 3.48 (4.00-3.26) 3.52 (4.14-3.02) 3.4 (1.2-3.8) 4.0 (1.2-5.0) 1.09 (0.3-1.27) 1.18 (0.29-1.79) 3.12 (4.00-2.99) 3.39 (4.14-2.79) 9.5/8.8/8.0/6.7 335/311/282/237 10.0/9.3/8.5/7.0 353/328/300/247 5.0 (1.7-5.3) 5.8 (1.7-6.0) 1.65 (0.44-1.93) 1.92 (0.4-2.04) 3.03 (3.86-2.75) 3.02 (4.25-2.94) 6.0 (1.7-6.5) 7.0 (1.7-8.0) 2.13 (0.44-2.49) 2.32 (0.4-3.18) 2.82 (3.86-2.61) 3.02 (4.25-2.52) 12.0/11.0/10.0/8.4 424/388/353/297 16.0/14.8/13.5/11.2 565/523/477/395 37/35/33/31 38/36/34/32 200X1,100X620 30 ---------m3/min cfm Pa(mmH2O) dB(A) mm kg °CWB °CDB kW kg dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 40 35/33/31/29 200X900X620 25 27 14 to 23 10 to 30 Ivory white Hermetically sealed swing type 0.6 1.0 (Charged for 10 m) 1.1 1.5 (Charged for 10 m) 47/44 48/45 49/46 49/46 550X765X285 34 735X825X300 48 10 to 46 -15 to 18 -15 to 20 o/ 6.4 o/ 9.5 o/ 12.7 VP20 (I.D o/ 20XO.Do/ 26) o/ 18.0 (Hole) 20 15 30 20 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. CEILING SUSPENDED TYPE 50 Model Name Power supply Cooling capacity1 Rated (Min. - Max.) COP 71 100 125 140 100 125 Outdoor unit RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Outdoor unit 1 Phase, 220-240 V, 50 Hz 5.0 5.8 (2.5-5.6) (2.9-6.0) kW kW Cooling1 Heating2 Cooling Heating Colour Fan Airflow rate (H/M/L) Outdoor unit Sound level (H/M/L)3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Cooling/Heating3 Night quiet mode Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW W/W W/W 6.0 (3.5-7.0) 7.0 (3.5-8.0) 1.39 1.67 3.60 3.60 m3/min cfm dB(A) mm kg °CWB °CDB 1.63 2.05 3.56 3.42 5.8 (3.2-8.0) 1 Phase, 240 V, 50 Hz 9.2 11.2 (5.0-11.2) (5.7-14.0) 13.2 (6.2-15.4) 3 Phase, 415 V, 50 Hz 13.2 9.2 11.2 (6.2-15.4) (5.0-11.2) (5.7-14.0) 7.5 (3.5-9.0) 10.5 (5.1-12.8) 16.0 (6.2-18.0) 10.5 (5.1-12.8) 1.77 2.32 3.28 3.23 White 17/-/14 600/-/494 39/-/35 195X1,160X680 27 2.93 3.33 3.14 3.15 kg dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 1.3 1.6 2.75 (Charged for 30 m) 3.70 4.35 3.03 3.10 1.7 1.9 2.4 3.7 (Charged for 30 m) 3.1 49/51 50/52 45 46 1,170X900X320 98 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 (equivalent length 70) 2.3 49/51 2.7 4.3 (Charged for 30 m) 50/52 45 1,345X900X320 108 75 (equivalent length 90) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 37 16.0 (6.2-18.0) Hermetically sealed scroll type 48/50 44 770X900X320 68 30 13.5 (6.0-16.2) 4.40 2.85 3.55 4.33 5.00 3.26 4.35 4.93 3.00 3.23 3.15 3.04 3.20 3.22 3.10 3.24 Fresh white White Fresh white 34/29/24 24/-/20 30/-/25 34/29/24 24/-/20 30/-/25 847/-/706 1,059/-/883 1,200/1,024/847 847/-/706 1,059/-/883 1,200/1,024/847 46/42/38 42/-/37 44/-/39 46/42/38 42/-/37 44/-/39 195X1,400X680 195X1,590X680 235X1,590X690 195X1,400X680 195X1,590X680 235X1,590X690 38 38 32 35 32 35 14 to 25 15 to 27 Ivory white Hermetically sealed swing type kW 13.5 (6.0-16.2) 50 60 71 FBQ60BV1A FBQ71BV1A RXS50FAVMA RXS60FVMA RXS71FVMA kW kW W/W W/W 5.0 (1.7-5.6) 6.0 (1.7-7.0) 1.98 (0.44-2.25) 1.93 (0.4-2.52) 2.53 (3.86-2.49) 3.11 (4.25-2.78) 1 Phase, 220–240 V, 50 Hz 5.7 (1.7-7.0) 7.0 (1.7-8.0) 2.23 (0.44-2.83) 2.26 (0.4-2.94) 2.56 (3.86-2.47) 3.10 (4.25-2.72) ---------- 6.7 (2.3-8.0) 8.2 (2.3-10.0) 2.57 (0.57-3.26) 2.67 (0.45-3.85) 2.61 (4.04-2.45) 3.07 (5.11-2.60) m3/min cfm m3/min cfm 13/9 459/318 14/10 494/353 2.9 46 Indoor unit Model Name Outdoor unit Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption COP Indoor unit Heat pump FBQ50BV1A 140 FHQ50BVV1V FHQ60BVV1V FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA Indoor unit Sound level 60 Indoor unit Heating capacity2 Rated (Min. - Max.) Power consumption CEILING MOUNTED BUILT-IN TYPE Heat pump Outdoor unit kW kW Cooling1 Heating2 Cooling Heating Colour Fan Air flow rate Cooling (H/L) Heating External static pressure3 Pa (High-Standard-Low) Sound level (H/L)4 dB(A) mm Dimensions (HXWXD) kg Machine weight Cooling CWB Certified Operation range Heating CDB Colour Outdoor Type Compressor unit Motor output kW kg Refrigerant charge (R-410A) dB(A) Sound level4 Cooling/Heating mm Dimensions (HXWXD) kg Machine weight Cooling CDB Certified Operation range Heating CWB mm Piping Liquid connections mm Gas Indoor unit mm Drain Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation 18/13 636/459 19/14 671/494 88-49-20 33/29 300X700X800 34 34/30 300X1000X800 41 14 to 23 10 to 30 Ivory white Hermetically sealed swing type 1.1 1.5 (Charged for 10 m) 49/49 47/48 735X825X300 48 1.92 2.3 (Charged for 10 m) 52/52 770X900X320 71 10 to 46 -15 to 18 o/ 6.4 o/ 15.9 o/ 12.7 VP25 (I.D o/ 25XO.D o/ 32) o/ 18.0 30 20 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 2 Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Initial setting is standard. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 38 SPECIFICATIONS OPTIONS Indoor unit DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE 50 Model Name Cooling capacity1,3 Rated (Min. - Max.) Heating capacity2,3 Rated (Min. - Max.) Power consumption COP Indoor unit 71 100 CEILING MOUNTED CASSETTE TYPE Heat pump 125 140 100 125 Kit name 140 Indoor unit FBQ50DV1V FBQ60DV1V FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 Name of option Outdoor unit RZQ50KBV1V RZQ60KBV1V RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Decoration panel Sealing material of air discharge outlet Panel spacer Fresh air Chamber type intake kit1 Indoor unit Outdoor unit Power supply 60 kW kW Cooling1 Heating2 Cooling Heating Colour Fan Airflow rate (H/L) External static pressure (Middle-High) Sound level (H/L)5 Air filter Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Outdoor Colour unit Type Compressor Motor output Refrigerant charge (R-410A) Cooling/Heating5 Sound level Night quiet mode Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW W/W W/W 1 Phase, 220-240 V, 50 Hz 5.0 5.8 (2.5-5.6) (2.9-6.0) 6.0 7.0 (3.5-7.0) (3.5-8.0) 1.35 1.59 1.38 1.76 3.70 3.65 3.98 4.35 m3/min cfm 7.1 (3.2-8.0) 8.0 (3.5-9.0) 2.22 2.43 3.20 3.29 18/15 635/530 1 Phase, 220-240 V, 50 Hz 1 Phase, 240 V, 50 Hz 13.1 10.0 12.5 (6.2-15.4) (5.0-11.2) (5.7-14.0) 16.0 11.2 14.0 (6.2-18.0) (5.1-12.8) (6.0-16.2) 3.17 3.97 4.16 3.15 3.95 4.68 3.15 3.56 37/32 mm kg °CWB °CDB 300X1,000X700 36 dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm 3.42 39/28 1,377/988 3.56 3.54 3.42 32/23 1,130/812 39/28 1,377/988 38/33 40/36 50-200 4 dB(A) kg 3.54 ---------- 32/23 1,130/812 Pa kW 3 Phase, 415 V, 50 Hz 13.1 12.5 10.0 (6.2-15.4) (5.7-14.0) (5.0-11.2) 16.0 11.2 14.0 (6.2-18.0) (5.1-12.8) (6.0-16.2) 3.17 3.97 4.16 3.15 3.95 4.68 38/33 40/36 ---------- 6 300X1,400X700 46 14 to 25 15 to 27 Ivory white Hermetically sealed swing type 1.7 1.3 1.6 2.75 (Charged for 30 m) 48/50 44 770X900X320 68 m 50 (Equivalent length 70) 30 m Hermetically sealed scroll type 2.9 2.4 1.9 2.4 3.7 4.3 (Charged for 30 m) (Charged for 30 m) 49/51 50/52 49/51 50/52 45 46 45 1,345X900X320 1,170X900X320 98 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 75 (Equivalent length 90) 30 Both liquid and gas piping 1.9 2.9 46 Remark FCQ50LUV1V FCQ60LUV1V FCQ60LUV1 FCQ71LUV1 FCQ100LUV1 FCQ125LUV1 FCQ140LUV1 BYCP125K-W1 KDBH55K160F KDBP55H160FA KDDP55B160 KDDP55B160K KDDP55X160 KKSJ55KA160 Without T-joint pipe and fan With T-joint pipe, without fan Direct installation type 2 Chamber connection kit Insulation kit for high humidity (Colorimetric method 65%) High-efficiency filter (including chamber) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) Filter chamber Replacement long-life filter Ultra long-life filter Replacement ultra long-life filter Branch duct chamber Cooling only Wireless type Remote controller Heat pump Wired type3 Navigation Remote Controller Wired type3 Central remote controller4 Unified ON/OFF controller4 Schedule timer4 Touch Controller4 Adaptor for wiring5 Wiring adaptor for electrical appendices5 Installation box for adaptor PCB Remote sensor (for indoor temperature) KDTP55K160 KAFP556B160 KAFP557B160 KAFP552B160 KAFP553B160 KDTP55K80 KAFP556B80 KAFP557B80 KAFP552B80 KAFP553B80 KDDFP55B160 KAFP551K160 KAFP55B160 KAFP55H160H KDJP55B80 KDJP55B160 BRC7F633F BRC7F632F BRC1C61 BRC1E62 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1C63 KRP4AA53 KRP1H98 KRCS01-4B Note: 1Refer to page 12 for the details. 2 Required for installing high-efficiency filter or ultra long-life filter. 3 Wiring for wired remote controller to be procured locally. 4 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5 Installation box for adaptor PCB (KRP1H98) is necessary. Round flow type: List of optional parts required to achieve different flow patterns Note : Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Capacities are net, including a deduction for cooling for indoor fan motor heat. 4 Initial setting is standard. 5 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 6 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more. 1 For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. 2 All round flow 4-way flow FLOOR STANDING TYPE Heat pump 50 Model Name Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption COP Indoor unit Outdoor unit Optional accessory parts 60 71 100 125 140 100 125 Indoor unit FVQ50CVE Outdoor unit RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB Outdoor unit kW kW Cooling1 Heating2 Cooling Heating Colour Fan Airflow rate (H/M/L) Sound level (H/M/L)3 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Cooling/Heating3 Night quiet mode Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Sound level Max. installation level difference Heat insulation kW kW W/W W/W m3/min cfm dB(A) mm kg °CWB °CDB kW kg dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 1 Phase, 240 V, 50 Hz 7.1 10.0 (3.2-8.0) (5.0-11.2) 8.0 11.2 (3.5-9.0) (5.1-12.8) 2.33 3.28 2.61 3.67 3.05 3.07 3.05 3 Phase, 415 V, 50 Hz 12.5 10.0 13.5 (5.7-14.0) (5.0-11.2) (6.2-15.4) 14.0 11.2 16.0 (6.0-16.2) (5.1-12.8) (6.2-18.0) 3.28 4.39 5.40 3.67 4.26 5.28 3.05 2.85 2.50 3.05 3.29 3.03 12.5 13.5 (5.7-14.0) (6.2-15.4) 14.0 16.0 (6.0-16.2) (6.2-18.0) 4.39 5.40 4.26 5.28 2.85 2.50 3.29 3.03 Fresh white 18/16/14 28/25/22 28/26/24 30/28/26 28/25/22 28/26/24 30/28/26 635/565/494 988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48 1,850X600X270 1,850X600X350 39 47 14 to 25 15 to 27 Ivory white Hermetically sealed swing type Hermetically sealed scroll type 1.3 1.6 1.7 2.4 3.1 1.7 2.2 2.9 1.9 2.75 3.7 4.3 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 48/50 49/51 50/52 49/51 50/52 44 45 46 45 46 770X900X320 1,345X900X320 1,170X900X320 68 98 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 50 75 30 (Equivalent length 70) (Equivalent length 90) 30 Both liquid and gas piping 5.0 (3.2-5.6) 6.0 (3.5-7.0) 1.27 1.52 3.94 3.94 Independently installable optional parts 140 5.8 (3.2-6.0) 7.0 (3.5-8.0) 1.78 2.15 3.26 3.26 Panel/grille related Panel spacer Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related Panel spacer1 High-efficiency filter2 Ultra-long-life filter2 Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o 1 o o o x o o o o o o o o o x x o o o o x o o o High-humidity operation kit High-efficiency filter2 Ultra-long-life filter2 x o x o o o o o x o o o o x x x x x High-humidity operation kit High-efficiency filter2 x o x o x x x x x x x High-humidity operation kit High-efficiency filter2 Ultra-long-life filter2 x x x x x x o o o 3-way flow 2-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related Ultra-long-life filter2 Panel spacer1 Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o3 o3 o3 o3 x o3 o o o o o3 o x x o o3 o x o o Ultra-long-life filter2 o3 o o o x Branch duct connection Optional accessory parts Independently installable optional parts duct1 Branch (Chamber type) (Round duct type) 1-way branch / unit 3-way flow 2-way branch / unit 2-way flow 1-way branch / unit 2-way flow Panel spacer1 o x x Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o o o 4 4 4 1 In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. 2 Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position. 3 It is not possible to use panel spacers in a 2-way flow installation. 4 It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 39 40 OPTIONS Indoor unit Indoor unit CEILING MOUNTED BUILT-IN TYPE COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE Name of option Decoration panel Remote controller Kit name Remark Wireless type FFQ50BV1B FFQ35BV1B BYFQ60B8W1/BYFQ60B3W1 BRC7E531W BRC7E530W BRC1C61 BRC1E62 KRP1BA57 KRP4AA53 KRCS01-1B KRP1BA101 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 DTA112BA51 KAFQ441BA60 KDDQ44XA60 KDBH44BA60 KDBQ44BA60A FFQ25BV1B Cooling only Heat pump Wired type1 Wired type1 Navigation Remote Controller Adaptor for wiring2 Wiring adaptor for electrical appendices2 Remote sensor (for indoor temperature) Installation box for adaptor PCB Central remote controller3 Unified ON/OFF controller3 Schedule timer3 Touch Controller3 Interface adaptor for SkyAir series Replacement long-life filter Fresh air intake kit Direct installation type Sealing material of air discharge outlet Panel spacer FFQ60BV1B Name of option Remark Service panel Air discharge adaptor Remote controller Wireless type Wired type1 Navigation Remote Controller Wired type1 Adaptor for wiring (interlock for fresh air intake fan) Wiring adaptor for electrical appendices Interface adaptor for SkyAir series Central remote controller2 Unified ON/OFF controller2 Schedule timer2 Touch Controller2 Kit name FBQ60BV1A FBQ50BV1A KTB25KA56W KDAJ25K56A FBQ71BV1A KTB25KA80W KDAJ25K71A Heat pump BRC4C62 BRC1C61 BRC1E62 KRP1BA54 KRP4AA51 DTA112BA51 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 Note: 1Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA112BA51. Note: 1Wiring for wired remote controller to be procured locally. 2 Installation box for adaptor PCB (KRP1BA101) is necessary. 3 This optional accessory requires DTA112BA51. DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE Kit name Name of option CEILING SUSPENDED TYPE Name of option High-efficiency filter1 Remark Resin net Replacement long-life filter Fresh air intake kit Drain pump kit L-type piping kit (for upward direction) Remote controller Wireless type FHQ35BVV1B FHQ50BVV1V KAF501DA56 KDU50N60VE KHFP5MA35 Cooling only Heat pump Wired type1 Wired type1 Navigation Remote Controller Central remote controller Unified ON/OFF controller Schedule timer Touch Controller Adaptor for wiring Wiring adaptor for electrical appendices4 Interface adaptor for SkyAir series Installation box for adaptor PCB Remote sensor (for indoor temperature) Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) ---------------------------- Kit name FHQ60BVV1V FHQ140CAVEB FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ60BVV1G FHQ140CAVEA KAF501DA80 KAF501DA112 KAF501DA160 KAFP501A160 ---------KDDQ50A140 KDU50N125VE KDU50P140VE KHFP5MA160 KHFP5N160 BRC7EA66 BRC7GA56 BRC7EA63A BRC7GA53 BRC1C61 BRC1E62 DCS302CA613 DCS302CA612 DCS301BA612 DCS301BA613 DST301BA612 DST301BA613 DCS601C513 DCS601C512 KRP1BA54 KRP4AA52 ---------DTA112BA51 KRP1D93A KRP1CA93 KRCS01-4B KRCS01-1B KJB311AA KJB212AA Note: 1Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA112BA51. 3 FHQ140CA is equipped standardly with the interface adaptor for SkyAir series. DTA112BA51 is unnecessary. 4 Installation box for adaptor PCB is necessary. CEILING MOUNTED SLIM DUCT TYPE Name of option Remark 65% 90% Filter chamber Replacement long life filter Replacement long life filter chamber kit Service panel Air discharge adaptor Remote controller Wireless type FBQ60DV1V FBQ50DV1V FBQ60DV1 KAF372AA80 KAF373AA80 KDDF37AA80 KAF371AA80 KAF375AA80 KTB25KA80W KTBJ25K80F KTBJ25K80T KDAJ25K71A Cooling only Heat pump FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1 KAF372AA160 KAF373AA160 KDDF37AA160 KAF371AA160 KAF375AA160 KTB25KA160W KTBJ25K160F KTBJ25K160T KDAJ25K140A BRC4C64 BRC4C62 BRC1C61 BRC1E62 KRP1C64 KRP4AA51 KRCS01-4B KRP4A96 5,6 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 Wired type2 Navigation Remote Controller Wired type2 Adaptor for wiring (interlock for fresh air intake fan) Wiring adaptor for electrical appendices Remote sensor Mounting plate for adaptor PCB.4 Central remote controller3 Unified ON/OFF controller3 Schedule timer3 Touch Controller3 Note: 1If installing a high efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required. 2 Wiring for wired remote controller to be procured locally. 3 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 4 Mounting plate for adaptor PCB is necessary for each adaptor marked . 5 Up to 2 adaptors can be fixed for each mounting plate. 6 Only one mounting plate can be installed for each indoor unit. FLOOR STANDING TYPE Kit name FDXS25CVMA FDXS35CVMA controller1 Wired remote Wired remote controller code Remark FDXS60CVMA KDT25N50 Name of option Replacement long-life filter Remote controller Navigation Remote Controller Central remote controller2 Unified ON/OFF controller2 Schedule timer2 Touch Controller2 Adaptor for wiring3 Wiring adaptor for electrical appendices Installation box for adaptor PCB BRC944B2 BRCW901A03 BRCW901A08 KRC72A KRP413AB1S KKF917A4 KRP928BB2S DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KDGF19A45 Length 3 m (shielded wire) Length 8 m (shielded wire) 5-room centralised controller2 Adaptor PCB (normal open/normal open pulse contact)3 The remote controller loss prevention with the chain Interface adaptor for DIII-NET use Central remote controller4 Unified ON/OFF controller4 Schedule timer4 Touch Controller4 Suction grille Insulation kit for high humidity FDXS50CVMA KDT25N63 Remark FVQ50CVE Wired type1 Wired type1 FVQ60CVE Kit name FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB KAFJ95L160 BRC1C61 BRC1E62 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1BA57 KRP4AA52 KRP4AA95 Note: 1Wiring for wired remote controller to be procured locally. 2 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 3 Installation box for adaptor PCB (KRP4AA95) is necessary. Note: 13 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary . 2 Adaptor PCB (KRP413AB1S) is also required for each indoor unit. 3 Time clock and other devices should be obtained locally. 4 This optional accessory requires KRP928BB2S. 41 42 OPTIONS DIMENSIONS Outdoor unit CEILING MOUNTED CASSETTE TYPE Kit name Cooling only Remark RXS25EBVMA Air direction adjustment grille Drain plug RXS35EBVMA KPW937A4 One set includes 5 pieces for 5 units RXS71FVMA 167 160 67 950 29 95 93 160 124 95 110 B arrow view [FCQ50-71LU] Connection position of branch duct (square-shaped type) [FCQ100-140LU] 157 350 A 4 1 2 35 or less (Note 4) Connection position of branch duct (round shape type) 55 27-M4 Prepared hole 5 95 167 93 29 60 42 105 160 298 125 165 157 3 840 81 2x100=200 85 160 64 50 130 Connection position of branch duct (square-shaped type) 20 C/L 280 330 157 350 213 C/L 80 90 183 ø10 (kn 0 ock hole ) Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) C arrow view Required space 200mm or more 55 150 340 80 2x100=200 80 160 350 67 95 29 90 196 ø10 (kn 0 ock hole ) C arrow view [FCQ100-140LU] 55 840 2x100=200 80 25 160 2x100=200 25 213 80 Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) 160 90 35 or less (Note 4) Connection position of branch duct (square-shaped type) C/L 90 130 256 157 350 124 20-M4 Prepared hole 5 95 110 124 60 55 42 105 2 280 330 840 81 2x100=200 85 64 124 50 1500 or more (required space) 160 From the floor side 2500 or more For height installation 1 150 125 165 256 35 or less (Note 4) Connection position of branch duct (round shape type) 157 4 55 3 167 93 Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 80 [FCQ50-71LU] 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 160 124 109 95 Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 256 157 350 A 1500mm or more 1500mm or more 1500mm or more 200mm or more 1500mm or more The necessary space is 500mm or more when the air-outlet is blocked with the accessory. Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more. 35 or less (Note 4) Connection position of branch duct (square-shaped type) KPW945A4 KKP937A4 KKP945A4 Notes: 1 Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4 Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured. 5 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 43 16-M4 Hole 157 350 Connection position of branch duct (square-shaped type) 7 16-M4 Prepared hole 50 40 RXS60FVMA B arrow view 6 [FCQ100-140LU] Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) Connection position 85 of branch duct (round shape type) 2x100=200 160 C/L Drain Connection Side 95 110 124 850 Adjustable(0~675) 350 55 16-M4 Hole 157 350 1500 or more 67 (required space) 160 From the floor side 2500 or more For height installation Name of option 840 340 80 2x100=200 80 124 Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) Kit name Heat pump RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ71KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A KKPJ5F180 K-KYZP15C KPT-60B160 KRP58M51 Kit name Heat pump RXS50FVMA RXS50FAVMA C 81 A arrow view 20 C/L 160 288 10 Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor 8 Pipe Connection Side [FCQ50-71LU] 55 Note 2 [FCQ100-140LU] Connection position 85 of branch duct (round shape type) 2x100=200 124 C/L 81 420 KHRP58P216T RZQ60KBV1V RZQ60KBV4A [FCQ50-71LU] 950 780(Hanging bolt pitch) 9 860~910(Ceiling opening space) (Note 4) 710(Hanging bolt pitch) 420 RZR140LUY1 Kit name Cooling only RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG KPW937A4 KPW945A4 KKP937A4 RZQ50KBV1V RZQ50KBV4A 300 or less 95 167 Name of option KKPJ5F180 K-KYZP15C KPT-60B160 KRP58M51 KHRP58P216T 860~910(Ceiling opening space) (Note 4) KKPJ5G280 ---------KKTP5B112 850 Adjustable(0~675) One set includes 5 pieces for 5 units [FCQ50-140LU] B ---------- Remark [FCQ50-140LU] RZR140LVVM 175 RZR100LUY1 Name of option RZR125LVVM Kit name Cooling only RZR125LUY1 KKPJ5F180 K-KYZP15C KPT-60B160 KRP58M51 Name of option Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor Refrigerant branch piping kit For twin multi RZR100LVVM 175 29 Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor Refrigerant branch piping kit For twin multi RZR60LUV1V RZR71LVVM RZR60LVVM KKP014A4 ------------------------------------- 160 246 10 RZR50LUV1V RZR50LVVM 50 40 Name of option Air direction adjustment grille Drain plug (Unit: mm) 1 2 3 4 5 6 7 8 9 Liquid pipe connection Gas pipe connection Drain pipe connection Transmission wiring connection Remote controller wiring connection Air-outlet Suction grille Corner decoration cover Drain hose (accessory) 44 DIMENSIONS (Unit: mm) CEILING SUSPENDED TYPE 1500mm or more* 575 62.5 1500mm or more* 295 or more 196 4 A *When the discharge grill is closeout, the required space is 200mm or more. 57 13 30 or more (Service space) 1590 Obstacle Floor side 6 76 3 Drain pipe connection 4 Power supply connection 5 Remote control code and control wiring connection 6 Air discharge grille 7 Suction grille 8 Drain hose CEILING SUSPENDED TYPE 225 275 300 275 6 80 3 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 (Applies to FHQ35-71BV only) The remote control code is the standard <about 3 m outside the machine> attached. (0.5 mm2 2 wicks O.D. 5.4) (It is not attached to VRV.) 2 7 5 80 105 170 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 900 240 or more 20 or more 20 or more 5 (Required space) 300 1 130 63 20-M5 Holes (All around) Air discharge grille Air suction grille Air filter Gas pipe connection Liquid pipe connection Drain pipe connection Earth terminal (inside the electric components box)(M4) Suspension bracket Backward pipe and wiring connection opening lid Upward pipe and wiring connection opening lid Right side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in piping back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection 170 100 30 18-M4 Holes (All around) 10 100 160 180 90 50 20 10 2 860 4xP150=600 Liquid pipe connection Gas pipe connection Socket for drain Drain hose (Standard accessory) Control box Infrared receiver unit connection Power supply connection Suspension bracket Air filter (Standard accessory) Protection net Allow view A 880 90 1 2 3 4 5 6 7 8 9 10 Inspection door (ceiling opening) 90 57.5 80 Ceiling 14 Brand name plate (Note.2) The Front Obstacle Floor side 4 o/ 45 55 21 30 or more (Service space) 12.5 B 30 or more (Service space) Suspension bolt 4-M8~M10 153 6 80 11 90 155 55 300 or more 13 (Required space) 195 5 (All around) 22-o/ 4.7 Hple 8xP100=800 940 (Suspension bolt pitch) 8 Position : Hole of wall for taking out in piping back (View from the front) 400 or more (In case of bottom suction) A 《Service space》 47 1 40 5 (Required space) For height installation From the floor side 2500 or more 155 Hanging bolt 4-M8~M10 Drain pipe connection VP20 (For left piping) 45 15 500 (Suspension bolt pitch) 105 8 A (Hanging position) 680 4 620 60 10 620 127 200 170 1550 1590 65 60 Position slit hole for taking out in piping back (View from the front) 330 3 4 5 7 150 100 90 80 7xP100=700 780 800 820 《In case of back-suction》 9 20-M5 Holes (All around) 10 200 180 160 100 FHQ125BVV1B 50 10 20 50 1360 1400 83 105 156 300 or more (Service space) 900 115 60 1120 1160 FHQ100BVV1B 5 [FDXS25-50CVMA] 65 FHQ71BVV1B 7 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 5 135 (Required space) 1120 1160 2 Position : Hole of wall for taking out in piping back (View from the front) 145 60 135 1120 1160 FHQ60BVV1G 40 FHQ60BVV1V 9 12 85 102 160 185 192 36 1120 1160 210 FHQ50BVV1V 260 B 960 170 105 90 18 17 16 142 58 (Hanging position) A 920 3 14 CEILING MOUNTED SLIM DUCT TYPE [FHQ35-125BV] FHQ35BVV1B 220 103 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection 5 Liquid pipe connection 6 Drain pipe connection 7 Earth terminal (inside the control box) (M4) 8 Hanger 9 Rear piping penetration cover 10 Top panel penetration cover 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection 19 Power supply wiring and a unit wiring back connection 20 Power supply wiring and a unit wiring upper connection Brand name plate (Note.2) 1 Liquid pipe connection 2 Gas pipe connection 57 6 o/ 45 The Front Drain pipe connection VP20 (For left piping) Notes: 1 Sticking location for manufacture's label manufacture's label for indoor unit : on the bell mouth inside suction grille manufacture's label for decoration panel : on the inner frame inside suction grille 2 In case of using wireless remote controller, this position will be a signal receiver. refer to the drawing of wireless remote controller in detail. 3 When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4 Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured. 11 5 30 or more (Service space) 268 2 From the floor side 2500 or more 45 or less Note)4. 45 or less 1 1500 or more (Required space) Hanging bolt 4–M8 to M10 (180) 145 183 285 205 172 211 55 30 260 25 5 4 1 19 15 23 62.5 Hanging bolt 4-M8~M10 175 62.5 Position slit hole for taking out in piping back (View from the front) 1550 214 221 268 575 For height installation 62.5 63 134 59 91 131 197 1500mm or more* 3 12 (Hanging bolt pitch) 690 For height installation 750 Adjustable(0–545) Required space 1500mm or more* 51 60 10 157 63 210 260 320 116 235 B arrow view 7 A arrow view 9 8 300 or more (Required space) Outdoor air intake (Direct connection) 4–M4 Hole (Hanging bolt pitch) 89 100 5 (Required space) Piping connection side Ceiling B 150 533 (Hanging bolt pitch) 700 6 585–660 (Ceiling opening space) 210 Drain connection side Connection position of fresh air intake kit φ100(Knock out hole) 120 90 115 18 17 20 16 89 8 90 Note)2. From the floor side 2500 or more 197 700 210 156 105 102 131 57 40 300 or less 175 92 [FHQ140CAVEB(A)] 585–660 (Ceiling opening space) 533 (Hanging bolt pitch) 320 30 87 100 163 189 195 35 COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE 9 6 7xP100=700 780 800 820 130 100 90 80 Notes: 1 In case of back-suction, mount chamber cover to bottom side of the unit. In case of bottom-suction, mount chamber cover to back side of the unit. 2 Location of unit's Name Plate: control box cover. 3 Mount the air filter at the suction side. (Select its colorimethod (Gravity method) 50 % or more) It can not be equipped with air filter (accessory) when connecting duct to suction side. 4 Pipe specification FDXS25 FDXS35 《In case of bottom-suction》 FDXS50 o/ 9.5 (Flare connection) o/ 12.7 (Flare connection) 46 DIMENSIONS (Unit: mm) DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE CEILING MOUNTED SLIM DUCT TYPE [FBQ50/60DV1V, 60/71DV1] 300 CASE 1) 200 180 160 100 《In case of bottom-suction》 700 20 or more 200 or less 1000 200 or more or less 165 80 925 5 6 7 8 9 10 11 12 Liquid pipe connection Gas pipe connection Drain pipe connection Earth terminal (Terminal in Control box) Control box(Inside) Remote control wiring connection Power supply wiring and a transmission wiring Air discharge flange Air suction flange Hanger Socket (for maintenance) Drain hose(Accessory) A B C FBQ50BV1A 556 533 4X120=480 FBQ60/71BV1A 856 833 D A E 700 460 6X120=720 1000 760 F G 3X150=450 5X150=750 485 785 1 2 3 4 5 6 7 8 9 10 Liquid pipe connection Gas pipe connection Drain pipe connection Interunit wiring port Power wiring port Drain hole Discharge flange suction flange Switch box Inspection hole H I J 6X65=390 7X65=455 750 11X65=715 12X65=780 1050 Air outlet 2 6 Air inlet (Note.2) 5 169 11 290 28 7 4 700 Ceiling Control box 49 300 12 View (From the Air outlet) 713 or less 20-8X12 oblong hole (All around) Floor surface B Inspection Ceiling hatch 700 700 Inspection hatch 2 or more or more (SAME AS THE View B-1 View B-2 INDOOR UNIT SIZE OR MORE) 8X150=1200 1325 1350 (From the Air inlet) Notes: 1 Location of MANUFACTURE'S LABEL: Control box surface 2 Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more. 3 Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean. 4 Space for Service Works According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc. 1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A) 2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1) 3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2) 200 or less 200 or less 165 167 3 1 CASE 2),3) Inspection hatch 1 (450mmX450mm) Control box Inspection hatch 3 (SAME AS THE INDOOR UNIT SIZE +300 OR MORE) Control box 1700 or more 19X65=1235 1400 7X150=1050 700 or more (Service space) 300 195 46 Inspection hatch 450 or more 3X65=195 45 4 65 450 or more (Service space) B view 40 2X65=130 6 635 1185 3 65=195 2 (SAME AS THE INDOOR UNIT SIZE OR MORE) 20-8X12 oblong hole (All around) 1160 212 144 5 3 135 120 67 150 200 300 245 215 150 135 57 Service space 300 or more 6-M5 Hole (Circumference) 1 2 65=130 Suspension bolt 25 (467 or less) 50 65 800 440 315 Air inlet Fig.A 9 Fresh sir intake position 700 or less 232 Adjustable 25 60 Unit base Air outlet Air inlet 100 10 Inspection hatch Ceiling Control box 1400 or more 600 Control box 20 or more 160 P.C.D. 125 Inspection hatch 1 (450mmX450mm) 48- 4.7 Hole (All around) 300 or more (Note.4) 2500 or more (A case without the ceiling) H 160 228 I J (Suspension position) Air outlet CASE 1) 10 200 or less 631 (Hanging bolt pitch) 300 or more 27 9 300 Service space Note)2 View B-2 1 2 3 4 6X150=900 1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A) 2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1) 3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2) 40- 4.7 Hole (All around) (Knock hole) Notes: 1 Location of unit's Name Plate: Fan hosing surface. 2 If the ceiling is not removable, a 300 mm service space must be kept between the unit and the ceiling. 3 Mount the air filter at the suction side. (Select its colorimethod (Gravity method) 50 % or more) 700 or more [FBQ100/125/140DV1] 8 A view F G 513 80 630 (Suspension position) 27 47 3X65=195 7 4 28 12 300 300 or more (Note.4) 2500 or more (A case without the ceiling) 150 277 247 150 212 144 169 11 290 300 or less 245 215 150 145 C B Air inlet (Note.2) 5 8 E 300 or more 200 or less 65 2 6 Ceiling 700 Inspection hatch 2 or more (SAME AS THE INDOOR UNIT SIZE OR MORE) View B-1 18-8X12 oblong hole (All around) 150 277 247 150 7 150 208 1 B Inspection hatch According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc. A B 250 3 Control box Inspection hatch 3 (SAME AS THE INDOOR UNIT SIZE +300 OR MORE) Control box Control box DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE [FBQ50/60/71BV1A] D 1000 805 245 215 150 CEILING MOUNTED BUILT-IN TYPE 49 5X150=750 (From the Air outlet) 1205 16X65=1040 9 Notes: 1 In case of back-suction, mount chamber cover to bottom side of the unit. In case of bottom-suction, mount chamber cover to back side of the unit. 2 Location of unit's Name Plate: control box cover. 3 Mount the air filter at the suction side. (Select its colorimethod (Gravity method) 50 % or more) It can not be equipped with air filter (accessory) when connecting duct to suction side. Inspection hatch 1 (450mmX450mm) 950 Ceiling (From the Air inlet) Floor surface Notes: 1 Location of MANUFACTURE'S LABEL: Contro box surface 2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.) 3 Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean. 4 Space for Service Works 1438(Hanging bolt pitch) 10 20 50 6 130 100 90 80 Fig.A CASE 2),3) 700 or more (Service space) Air outlet 40 2X65=130 10 Air inlet Air outlet 785 167 24-M5 Holes (All around) 9xP100=900 980 1000 1020 450 or more (Service space) 59 Adjustable 9 (467 or less) 9xP100=900 980 1000 1020 《In case of back-suction》 Control box Unit base Inspection hatch Ceiling 760 Inspection hatch 450 or more 700 or less 100 100 160 180 150 100 90 80 7 5 3 16-8X12 oblong hole (All around) View 232 10 23 330 Air inlet Inspection hatch 1 (450mmX450mm) 9 50 20 10 24-M5 Holes (All around) 4 Control box 435 1 130 63 170 47 90 2 30 18-M4 Holes (All around) Air outlet Inspection door (ceiling opening) 1080 1060 6xP150=900 30- 4.7 Hole (All around) 8 1300 or more A 《Service space》 10 631 (Hanging bolt pitch) 11X65=715 1100 240 or more Ceiling Liquid pipe connection Gas pipe connection Socket for drain Drain hose (Standard accessory) Control box Infrared receiver unit connection Power supply connection Suspension bracket Air filter (Standard accessory) Protection net 1038(Hanging bolt pitch) 20 or more 20 or more 500 (Suspension bolt pitch) 57.5 1 2 3 4 5 6 7 8 9 10 Allow view A 80 12.5 21 Suspension bolt 4-M8~M10 27 30- 4.7 Hole (All around) 400 or more (In case of bottom suction) 60 620 (All around) 26-o/ 4.7 Hple 10xP100=1000 1140 (Suspension bolt pitch) 8 200 170 153 620 300 or more (Service space) 1100 13X65=845 [FDXS60CVMA] 1 2 3 4 5 6 7 8 9 10 11 12 Liquid pipe connection Gas pipe connection Drain pipe connection Earth terminal (Terminal in Control box) Control box(Inside) Remote control wiring connection Power supply wiring and a transmission wiring Air discharge flange Air suction flange Hanger Socket (for maintenance) Drain hose(Accessory) 48 DIMENSIONS (Unit: mm) FLOOR STANDING TYPE OUTDOOR UNIT // RKS50/60AVMG, RXS50FAVMA, RXS50/60FVMA [FVQ50/60CVE, 71/100/125/140CVEB] 825 260 In case of fixing it at the bottom In case vibration resistance is required, fix it at both the bottom and the rear. 330 Fixture (Accessory) re 1 0 50 or mo Required space 184 E 45 44 F 50 49 G H J K L 50 110 180 186 242 130 190 260 266 322 M 57 79 89 64 50 N P 144 149 202 229 50 50 OUTDOOR UNIT // RXS71FVMA 900 620 140 105.5 4–cuts for anchor bolts (M12) 376 30 320 350 (345-355) 380 117 102 71 13 29.5 30 45 191 Drain outlet (I. D o/ 25 hose for connection) Brand name label 765 12 Name plate 63 Gas stop valve Terminal strip with earth terminal Liquid stop valve Outdoor air thermistor Outdoor air thermistor Manufacture's Label Liquid stop valve ( 6.4CuT) Gas stop valve ( 9.5CuT) 104 90 30 67 Interconnecting piping and wiring inlet Gas pipe (o/ 15.9 single union) Liquid pipe (o/ 6.4 single union) 50 100 100 Wall height on air outlet side =less than 1200 Minimum space for air passage 350 150 50 50 50 100 50 350 50 300 100 126 50 105 165 78 108 100 Minimum space for air passage 22 350 Wall height on air outlet side =less than 1200 196 In case of removing stop valve cover 150 Indication label 410 770 550 Wiring inlet Service port 50 Gas stop valve (o/ 12.7 CuT) 490 Handle 8 18 30 100 Minimum space for air passage 4 - Holes for anchor bolts (M8 or M10) 574 Wall height on air outlet side =less than 1200 155 160 100 75 184 Liquid stop valve (o/ 6.4CuT) Service port 350 100 H J K L OUTDOOR UNIT // RKS25/35AVMG, RXS25/35EBVMA 285 Terminal strip with earth terminal 350 6 6 A B C D FVQ50/60CVE, 71CVEB 50 110 186 270 FVQ100/125/140CVEB 130 190 266 350 (I.D φ15.9 hose for connection) Outdoor air temperature thermistor Wiring inlet Brand name label 350 4 50 541 616 95 200 223 253 34 6 95 825 50 3 5 F Drain outlet In case of removing stop valve cover Name plate 100 G 598 311 mo 735 Full open position of suction grille Notes: 1 Sticking location for manufacturer’s label: on the surface of cover of switch box inside the suction grille. or 1 Suction grille 2 Air filter 3 Through hole for side piping (70x90 oblong slit hole) 4 Through hole for side piping ( 80 slit hole) 5 Through hole for side piping ( 27 slit hole) 6 Through hole for rear piping/wiring (80x130 oblong slit hole) 7 Through hole for bottom piping/wiring (126x130 square hole) 8 Liquid pipe connection 9 Gas pipe connection 10 Drain pipe connection 1 E 100 C 50 re 2-7X15 oblong hole (For wood screw) Approx.46 A B mo 4 –Holes for anchor bolts (M8 or M10) 2 9 10 580 re 740 or more (Pull out dimension of air-filter) 314 677 1850 8 or 300 D Pull out direction of air-filter 18 68 600 50 330 350 View 30 Detail (Two both sides) 124 Drain outlet (I.D. o/ 15.9 hose for connection) 25 130 N P 7 0.7 2 36 126 78 325 This model to be fixed with fixture as shown below. M Suction grille stopper 130 215 10 4- 14 Hole (For bolt) 49 50 DIMENSIONS (Unit: mm) OUTDOOR UNIT // RZR50/60LUV1V, RZR50/60/71LVVM OUTDOOR UNIT // RZR125/140LVVM, RZR100/125/140LUY1 131 573.5 320 43 300 61 78 350 (345~355) 845 30 Hole for anchor bolt 4-M12 Drain outlet I.D. 18 hose for connection 140 620 20 Hole for anchor bolts (M8 or M10) Name plate 140 900 30 7 30 300 326 342 41 94 4 3 Earth terminal in switch box Wiring inlet 2 1 5 89 55 53 19 19 142 8 71 Drain outlet 80 52 145 13 299 419 449 5 479 509 559 45 376 67 16 58 70 102 117 200 95 223 95 54 89 60 84 95 54 20 16 94 6 55 422 423 105 144 Service port 21 6 5 Gas stop valve ( 15.9CuT) Drain outlet 7 5 Liquid stop valve ( 9.5CuT) 272 112 163 269 Service port 7 6 60 595 1170 7 191 1 2 3 4 5 6 7 8 Gas pipe connection Liquid pipe connection Service port Earth terminal Refrigerant piping intake Power supply wiring intake Transmission wiring intake Drain outlet 1 2 3 4 5 6 7 8 Gas pipe connection Liquid pipe connection Service port Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake Control wiring intake Drain outlet OUTDOOR UNIT // RZQ50/60KBV1V, RZQ50/60KBV4A, RZQ71KCV4A OUTDOOR UNIT // RZR100LVVM Hole for anchor bolt 4-M12 320 91 160 41 140 3 94 140 620 900 30 3 4 2 1 7 6 5 4 7 6 5 6 5 416 595 51 55 19 13 71 8 67 1 2 3 4 5 6 7 8 Gas pipe connection Liquid pipe connection Service port Earth terminal Refrigerant piping intake Power supply wiring intake Transmission wiring intake Drain pipe connection 223 53 95 339 54 95 60 89 28 95 89 19 142 52 16 68 161 260 279 285 262 5 80 52 145 13 67 16 16 145 5 36 61 6 55 223 55 84 53 80 117 90 19 16 8 340 95 339 95 142 7 58 6 19 70 102 7 89 53 89 60 5 53 990 1 770 7 2 54 95 84 55 620 940 341 160 30 30 43 61 30 38 350 (345~355) 320 55 37 30 350 (345~355) 30 Hole for anchor bolt 4-M12 5 45 376 191 52 DIMENSIONS (Unit: mm) OUTDOOR UNIT // RZQ100/125/140KCV4A REMOTE CONTROLLER 30 Hole for anchor bolt 4-M12 Remote controller dimensions • CEILING MOUNTED CASSETTE TYPE <Round Flow> • Receiver installation procedure Transmitting part Refrigerant piping side 157 140 900 30 Drain piping side Refrigerant piping side 94 620 140 COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE • Receiver installation procedure Receiver 30 41 320 43 61 350 (345~355) Wireless type Receiver 3 4 Drain piping side 2 62 17.5 1 1170 Remote controller holder installation procedure <installation to wall surface> • 7 7 6 7 6 6 5 55 Remote controller holder 95 223 84 95 CEILING MOUNTED BUILT-IN TYPE DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE 53 54 54 (BYFQ60BW1) (BYFQ60B7W1) (BYFQ60B8W1) 55 423 422 95 60 89 89 • 19 19 80 52 145 13 CEILING SUSPENDED TYPE • Receiver installation procedure Receiver detail 2-5x9 Slot The Front 142 5 45 376 191 70 18 0.5 35 (Ceiling opening) Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain outlet 72 83.5 106 1 2 3 4 5 6 7 8 58 70 102 117 16 16 Receiver 67 120 71 8 Decoration panel • Receiver detail Liquid crystal remote controller (wireless) 5 5 Decoration panel • Receiver detail 49 • Receiver detail (Ceiling opening) Switch box (field Supplied parts) More than 90 (Srevice space) Service space for ceiling installation OUTDOOR UNIT // RZQ100/125/140HAY4A Note : Do not install more than 3 receivers in the vicinity of one another. With 4 or more units, there is always the possibility of malfunction Wired type • Remote controller dimensions BRC1C61 36 55 320 • Installation method 42 900 117 84 17 3 18 Cord outlet hole 23 28 (Between remote controller and control box) 17 16 58 71 102 117 5 53 191 Note) 1. Remote controller cord and staple are not attached. They are field supplied parts. B Embedded cord Staple Condit C Embedded cord (use switch box) 19 19 42 Top center outlet 84 84 40 95 84 95 2 40 55 500 m A Exposed cord Operation lamp (Green) Code outlet hole 120 19 5X7 oblong hole 80 52 145 13 1 2 3 4 5 6 7 8 28 23 46 5X15 oblong hole 48.5 48.5 Left outlet 19 Lower case portion Note)2 28 Through hole Switch box for one switch ( 8- 10) ex.) KJB111A (optional accessory) Lower case 67 8 376 0.75~1.25 mm 55 435 19 16 Size Total length Top left outlet 53 54 54 95 416 60 89 24 5 Shield wire (insulated thickness: 1 mm or more) • Installation method Lower case 6 6 5 Upper case 120 5 BRC1E62 7 7 6 223 1345 7 19 Control box Type 1 Through hole ( 12- 16) Specifications of cord 2 142 17 46 4 71 Remote controller 0~5 120 89 C Exposed body, embedded code Conduit 38 140 620 (Pitch of foundation bolt holes) 30 45 17 Remote controller Remote controller 120 91 140 B Exposed body, embedded cord Staple 30 38 A Exposed body, exposed cord 84 (Pitch of foundation bolt holes) 350 (345~355) 30 Hole for anchor bolt 4-M12 Gas pipe connection Liquid pipe connection Service port Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection Note) 1. Remote controller cord and staple are not attached. They are field supplied parts. Specifications of cord Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more) Size 0.75~1.25 mm2 Total length 500 m 46 0~5 Switch box for two switch (Between remote ex.) KJB211A controller and (optional accessory) control box) Switch box portion [field supplied part] 2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller. 54 Installation service space for outdoor unit For RZR50/60LU/LV, 70-140LVVM, RZR100-140LUY1 For RZQ50/60KBV1V/V4A, RZQ71-140KCV4A, RZQ100-140HAY4A 2.RZR100-140LVVM, RZR100-140LUY1 The values represent the case for the RZQ100-140KCV4A and RZQ100-140HAY4A. The dimensions in ( ) are for the RZQ50/60KB and RZQ71KCV4A (The unit values is mm. ) 2 When there is an obstruction on the outlet side 1) When the overhead space is open 1) When the overhead space is open 1. For single unit installation 1 2 re or mo 0 10 ore m or 1 25 0o ore 25 0o rm 10 ore 0o rm 10 0 1 or 0 10 ore m or mo re 0 00 or mo re 1 0 00 or mo re 100 ore or m 50 0 le or ss 1 An obstruction in the overhead space 50 0 le or 10 ore 0o rm 2 10 0 mo or re 10 0 mo or re When there are obstructions on both sides 10 00 0 30 ore m or 0o rm ore 50 r 0o mo re 50 0 m or 0o ore 0) 0( 0 50 m or 2. For multiple units installation (more than two units) 30 or 250 mo re 0o 0o rm ore 0o rm An obstruction in the overhead space ore 0 10 0o 0 rm 2) When there is an obstruction in the overhead space 0 10 ore m or 50 0 le or ss 2 rm When there is an obstruction on the inlet side ore 3 When there are obstructions on both the inlet and outlet sides (When the obstruction on the outlet side is higher than the unit itself) 1) When the overhead space is open ore 1. For single unit installation 1 1 or 000 mo re or 250 mo re 50 0 or s les An obstruction in the overhead space 0 20 ore m or r le re ss When there are obstructions on the inlet side and both sides An obstruction in the overhead space 50 150 or m 10 0o 0o r le 0o rm 1 or rm ss 0 00 or re mo e 3 When there are obstructions on both the inlet and outlet sides (When the obstruction on the outlet side is higher than the unit itself) 1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.) ore 150 e or rm 1. For single unit installation o 50 or m ore 1 2. For multiple units installation (more than two units) L 0o 1 H An obstruction in the overhead space 10 2 H 10 0 mo or re 50 0o r le 10 00 or mo or 200 mo re 0 30 ore m or 20 ore rm ore 00 10 ore m or 0 20 ore m or 55 Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book. L H 00 10 ore m or 0o ) 50 0 ( re 10 mo or 10 0 mo or re 10 0 mo or re rm ore rm 0o 2. For multiple units installation (more than two units) re 0o 25 ss 0 50 ore m or L When there are obstructions on the inlet side and both sides 1000 or more H L 50 s 1 or 000 mo re or 250 mo re L 0 10 ore m or 0 50 ore m or 2. For series installation (more than two units) s r le 1000 or more r 1000 or more An obstruction in the overhead space 2 0o mo 2 50 ore m 0 e or 0 5 or m or When there are obstructions on the inlet side and both lateral sides s les ss L 0 15 ore m or or 150 mo re 2. For series installation (more than two units) 1 r le ore 1. For single unit installation (There is no limit to the height of the obstruction on the outlet side.) or 150 mo re or 0o An obstruction in the overhead space L 15 0o ore 10 0 mo or re ss 10 ore in the overhead space 1000 or more 0o 50 25 50 2 le or H s s r le s 0 10 When there are obstructions on the inlet side and both lateral sides An obstruction 50 50 1000 or more 1000 or more 0o s 1000 or more m An obstruction in the overhead space les 1000 or more 10 r 0o 50 r 0o 1000 or more 2 1000 or more 0o 50 rm 1. For single unit installation 20 rm ore 1000 or more 50 1 s r le ore mo 20 20 When there is an obstruction on the inlet side or 150 mo re 50 ore 1. For single unit installation r le 0o re 2) When there is an obstruction in the overhead space 1 0 10 2. For series installation (more than two units) 1 rm An obstruction in the overhead space or 00 o 0 20 ore m or ss 0o 10 0 mo or re 10 0 mo or re ore 2. For multiple units installation (more than two units) ss ore or 250 mo re 2. For multiple units installation (more than two units) 2) When there is an obstruction in the overhead space rm or 250 mo re mo or or m 100 2 10 0 ) (50 10 2) When there is an obstruction in the overhead space When there are obstructions on both sides 1 50 re 1. For single unit installation 2. For series installation (more than two units) 1 or 000 mo re rm rm ore When there is an obstruction only on the inlet side ore When there are obstructions on both sides 0o ore rm 1000 or more ore 0o H rm 2 10 50 1. For single unit installation 2 1000 or more 0o 1. For single unit installation 2. For series installation (more than two units) When there are obstructions on both sides 1 1) When the overhead space is open 1) When the overhead space is open 2 0 50 ore m or 50 10 1 2 When there is an obstruction on the outlet side H When there is an obstruction only on the inlet side 1. For single unit installation 1 When there is an obstruction on the inlet side 1000 or more 1 When there is an obstruction on the inlet side 1000 or more 1.RZR50/60LU/LV, RZR71LVVM 0) 20 0 ( re 30 r mo o L H 0 30 ore m or 00 10 ore m or 0) 20 0 ( re 30 r mo o Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book. 56 MEMO 57 58