Download Amperes MX2222 Specifications

Transcript
amperes electronics sdn bhd
Co No : 509025-X
CONTENTS
Amperes Electronics is now in its 10th year
since its inception in 1999 in Puchong,
Malaysia and has been a name
synonymous with Public Address System.
Product offer ...
Be it large or small scale installation,
Amperes has something to offer with the
best available solution to meet the
demanding requirements and cost factors.
We build to cater the needs with
contemporary design and stress highly on
the quality.
Continuous development ...
Expansion of product range, continuous
product improvements, emphasis on R & D
as
well
as
production
process
modernisation has been core thrust of
Amperes development, thus ensuring
products rolled out are of the latest
technology.
Global acceptance ...
Amperes now existed in various countries
such as Singapore, Thailand, UAE, Brunei,
Philippines, Vietnam and Indonesia. The
list shall be expanded further in our
continuous effort to make Amperes a global
brand.
20
99 ~ 09
9
1
10
th
PMX SYSTEM
Music Server Software
1
PAGING MICROPHONE / INPUTS
PM1000 Series
Analogue Desktop Paging Microphones
PD2400
24 Zone Digital Paging Microphone
PD2800
Digital Paging Microphone
EP1200
Emergency Paging Panel
TC122 / CB110 / GM Mic
Microphones
CM1400
Chime and Siren Tone Generator
2
3
4
5
6
6
DATA
TE6000
TD6801 / TD6240
12 Ch Switching Data Encoder
Switching Data Decoder
7
7
PRE-AMPLIFIERS
MX2222
DA2208
12 Input Pre-amplifier Mixer
2 Input 8 Output Distribution Amplifier
8
9
MATRIMIX PAGING SYSTEM
MxP2188
MatriMix Paging Controller
PD1160
MatriMix Paging Microphone
EX1102 / MS1103
MatriMix Paging Mic Extender / Splitter
RP1104 / 1105
MatriMix Remote Zone Control & Source Input Panel
ER1108
MatriMix Emergency Paging Overriding Panel
10
11
11
11
11
MIXER AMPLIFIERS
MA2000 Series
MB2100 Series
60 / 120 W Mixer Amplifier with Zone Selection
60 / 120 W Basic Mixer Amplifiers
12
12
AMPLIFIERS
PA300 Series
PA2000 Series
PX2000 Series
10 / 20 / 30 W Mini Amplifiers
120 / 240 / 360 / 480 W 100V Power Amplifiers
120 / 240 / 360 / 480 W 100V Power Amplifiers w AFS
13
14
15
16
17
18
19
19
20
Amperes
believes
in
customers’
satisfaction and their recognition had been
the fuel for its existence and growth. We
believe in close working relationship with
our valued partners, evaluating and react to
every constructive critics with the objective
of producing better and more reliable
products through our continuous product
improvement policy.
SELECTORS
ZS5601 / 5121
ZS5602
6 / 12 Ch Speaker Zone Selector
6 Ch Uninterrupted Paging Speaker Zone Selector
21
22
POWER SUPPLIES
BC9730
PS9400
SQ9715
24V DC Automatic Battery Charger
24V DC 4A Regulated Power Supply
7 Ch Sequential Power Switcher
23
23
24
In short, we listen and react, seek and
apply the shared knowledge to achieve a
brand name of “ The Emerging Preference ”.
VOLUME CONTROLLERS
VC7000 / 8000 Series
VR7600 Series
AV7200
VP7501 / 7810
5 / 10 / 30 / 50 / 100W 100V Line Volume Controllers
5 Zone Rack Mounted Volume Controllers
Automatic Volume Controller
Speaker Patch Panel
25
26
26
27
SPEAKERS
CS Series
BS / CH Series
FS / LA Series
HS / SP Series
Ceiling Speakers
Surface Mount / Column Speakers
Foreground Music / Array Speakers
Horn Speaker / Sound Projector
28
29
30
31
ry
FAULT CHANGEOVERS & MONITORING
AC3601
6 Duty / 1 Standby Manual Changeover
AX700
6 Duty / 1 Standby Changeover Panel
AX3700
6 Duty / 1 Standby Auto Changeover Panel
AM6000
6 Ch Amplifier Monitor Panel
AS4000
Amplifier Surveillance Unit
LS4600
6 Ch Speaker Line Surveillance
A nni versa
customer’s satisfaction
a member of :
Fed of Malaysian Manufacturer ( FMM )
ISO 9001 : 2000
Certified Company
Design & Manufacturing of
Public Address Equipment
cert : 16895
ACCESSORIES
NOTES & REFERENCE
32
33
pmx
Introducing the new Amperes PMX System, a software based product which
is a sort of integration of various hardware components such as
programmable timer, chime & siren tone generator, message recorder /
player, CD player, music bank and paging station.
With PMX System, a significant amount is saved from investing in hardwares,
less maintenance and moreover, it is easily upgraded from time to time,
making it a product that never obsolete.
It can be easily installed in any standard PC ( see requirement ), interface it
with USB to RS485 converter ( provided ) for zone selection capability, or use
it merely as a music bank, link the audio and control output to existing PA
installation, and you shall get an enhanced system.
It is suitable for offices, public transportation stations, shopping malls, hotels,
factories, schools etc, where daily repetitive announcement is required.
software based pa system
pmx system - music server
Among the
windows available
in PMX System :
Scheduling, Media
Player, Zone
Setup and Paging
Window.
features
MEDIA PLAYBACK
Plays audio CD, MP3, WAV and other formats compatible with Window
media player from stored files, USB or through CD.
MUSIC / MESSAGE / TONE STORAGE
Stores unlimited songs, messages, tones or chimes in PC HDD for
playback with just clicks away.
WEEKLY PROGRAMMABLE TIMER
Allows repetitive playback of tone or message such as chime for lunch
breaks, morning calls, welcome greeting for work shift, etc.
SCHEDULED ACTIVATION
Scheduled broadcast such as birthday song can be programmed with
zone assignment.
ZONE CONFIGURATION
Zones can be named and grouped and assignable as Normal or
Emergency zone for privacy and convenience of paging.
BROADCAST ZONE ASSIGNMENT
Schedule paging, music playback can be assigned to certain zones
instead of blanket ALL CALL broadcast.
CONVENIENT INTEGRATION TO EXISTING SYSTEM
PMX can be easily integrated to existing installation for system enhancement
interfacing schematics
SECURITY PROTECTION
Admin and user levels with password avoids unnecessary tampering to
the system setup.
PC pre-loaded with
PMX Software and
licenced dongle
UPGRADES
System upgrades and free downloads shall be available free. Future
upgrades includes interfacing with BAS system, etc.
PC Mic
PACKAGE INCLUDES :
- Software CD
- USB dongle as license for single user
- USB to RS485 converter for interfacing with Amperes TD6801
or TD6240 decoder for zone selector activation
- USB cable
HARDWARE REQUIREMENTS
PC with Window XP operating system ;
Pentium 4 and above, 512 MB RAM and Monitor
Other Inputs
data
Paging
Mic
( Opt )
audio
MX2222
Mixer
USB-RS485
Converter
Amp
data
FOR ZONE ACTIVATION
Amperes TD6240 or TD6801 decoder
Amperes ZS5601 / 5121 / 5602 zone selectors
TD6240
Zone Decoder
Zone
Selector
USB - RS485
converter
Speakers
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 1
PM1000
PM1060
PM1120
Desktop Paging Microphone
pm1000 analogue series
6 Ch Desktop Paging Microphone
12 Ch Desktop Paging Microphone
PM1000 series are available in three variants and had been
serving many installations faithfully since its creation. They are
avaialble as simple paging mic with chime to those with 6 or 12
zone selections. They are most suitable for simple and small size
installations of less than 12 zones in total.
Features
Condenser gooseneck microphone with illuminated ring
paging microphones
Pre and post announcement 4 tone chime
Adjustable chime and mic volume with balance mic / line
output level
Output level selection to mic or line signal to suit the input type
of the pre-amplifier mixer
Dry contact available when mic is active ( PM1000 only )
6 or 12 zone selection for PM1060 and PM1120
technical specifications
PM1000 : 24V DC adaptor
Power requirement
PM1060 / 1120 : 24V DC via D9 conn.
Pwr consumption
50 mA / 150 mA / 150 mA
Zone selection
PM1000 - ALL CALL
PM1060 / 1120 - 6 and 12 zones w ALL CALL
Microphone
Condenser mic ; cardioid
Output impedance
600 Ohm
Output level
1.2 V ( line output ) / balanced mic ( 775 mV )
Output dry contact
3 A normally open ( PM1000 only )
Output controls
Chime and mic level
Audio connection
1/4 " stereo phone jack
Switching connection
D15 connector ( PM1060 / 1120 only )
Operating distance
300 m ( recommended )
Chime
4 tone up and 4 tone down
Indicators
Mic ring, zone switch, ALL CALL
Frequency response
100 ~ 12 KHz ( +/- 3dB ; 0 dB out )
S / N ratio
> 60 dB
application schematic
PAGING MIC
Gooseneck mic length 400 mm
Dimensions (WxHxD)
150 x 62 x 186 mm
Weight ( kg )
780 / 810 / 850 gms
Audio : 2C screen
MIXER
OFF
CH1
CH2
CH3
CH4
CH5
CH6
SOURCE
TUNER
MAX
POWER
PM1000 via
adaptor,
PM1060/1120 via
D conn
MIN
MAX
SIG IN
MIN
MAX
MIN
SIG IN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
SIG IN
MAX
MIN
POWER
TONE CTRL
OFF
MIN
MIN
SIG IN
rear view of
PM1000
SELECT
MASTER
EXT INPUT
MX 2222
MAX
MAX
CHIME
MIN
I
CASS
CD
amperes
O
AUX
MAX
MIXER
TREBLE
BASS
SIG IN
MIN
MAX
SIG IN
MUSIC SOURCE
E/M PAGING
MIC
TEST
FIRE
SIREN ACTIVATE
AM 6000
POWER
amperes
POWER AMP
PA 2060
60 Watts
POWER
POWER
AM 6000
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
SIGNAL -40 dB
Zone Control :
PM1000 - 2C
for all call,
PM1060/1120
- N + 3 core
rear view of
PM1060 / PM1120
N= zone qty
packing information
ZONE SELECTOR
ZS 5121
amperes
OVERRIDE
1
2
3
4
5
6
7
SPEAKER ZONE SELECT
8
9
10
11
12
ALL
CALL
TO LINE SURVEILLANCE /
VOLUME CONTROLLER /
SPEAKERS
Qty per carton : 1 unit
W x H x D : 525 x 85 x 270 mm
Weight
: PM 1000 - 1.8 kg ( incl adaptor )
: PM 1060 - 1.15 kg
: PM 1120 - 1.2 kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 2
PD2400
pd2000 series
24 Zone Digital Paging Microphone
PD2400 is suitable for mid size installations of up to 24 zones. It can be located
away in a distance of around 500m which utilizes RS485 for data communication
whereas the audio by using balanced line signal.
Features
The unit has individual key for zone selection with 4 groups and ALL CALL. 4 tone
chime is incorporated and shall be activated prior and after a paging.
24 zone paging control with 4 fixed groups and ALL CALL
RS485 data transmission for long distance remote paging
It shall be used with Amperes TD6801 or TD6240 decoder unit before connected to
the speaker zone selector for zone activation.
Balanced line output for low noise audio connection
Multi point paging with priority level setting ; up to 3
PD2400 can be connected to a single TD6801 or TD6240
4 tone pre and post announcement chime
BGM muting at zone selector when mic is activated ;
bypassing zone selection at rack level
High sensitivity condenser microphone
12V or 24V DC powering, whichever convenient
application schematic
PD2400
Unit 2
PD2400
Unit 1
technical specifications
24V DC via D9 connector /
Power requirement
ext 12V DC pwr adaptor
Power consumption
170 mA
Zone selection
24 individual zone key
ac/dc
adaptor
A C /D C
A C /D C
ac/dc
adaptor
PD2400
Unit 3
2 pair screen
A C /D C
Amperes
TD6240
decoder
4 groups ( preset of 6 zones )
ALL CALL
C H1
C H2
C H3
C H4
C H5
C H6
S OURCE
E X T INPUT
T O N E CTRL
O FF
M A S TE R
MX 2122
Microphone
Condenser mic ; cardioid
Output impedance
600 Ohm
Output level
1.2 V ( line output )
Output controls
Chime and mic level
Data output
RS485 ; 19.2 KB / s
Data connection
D9 connector
Operating distance ( data )
Up to 1000 m
Audio distance
Typ 500 m ( up to cable size )
Chime
4 tone up and 4 tone down
Indicators
Mic ring, zone
Frequency response
100 ~ 12 KHz
S / N ratio
> 60 dB
Gooseneck mic length
400 mm
Dimensions (WxHxD)
292 x 62 x 186 mm
Weight ( kg )
1.2 kg ( excl. adaptor )
paging microphones
Chime and mic volume control
Control
Connection
via RJ45
S E L ECT
T UNER
O FF
M IN
M IN
S IG IN
MAX
M IN
S IG IN
MAX
M IN
S IG IN
MAX
M IN
S IG IN
MAX
M IN
S IG IN
MAX
M IN
MAX
S IG IN
M IN
S IG IN
MAX
MA X
C H IM E
M IN
P OWER
I
C ASS
CD
AUX
MA X
M IX ER
T R E BLE
B A SS
M IN
MAX
S IG IN
O
MX2222
M U S IC S OURCE
Audio Signal
Power
Amplifier
Speaker Cable
ZS5121
Zone 1 to 12
ZS5121
Zone 13 to 24
Add Volume
Controllers If
Required
Speaker Distributions
rear view
packing information
VOLUME ADJUST
PIN CONNECTIONS
S/N :
PIN 1 : GND
PIN 2 : +OUT
PIN 3 : -OUT
PIN 4 : B
PIN 5 : A
PIN 6 : -24V
PIN 7 : +24V
PIN 8-9 : NC
CHIME
MIC
LINE OUT BALANCE
DATA OUT
ON
DC 24V
PR2
PR1
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
Quality Product From
AMPERES ELECTRONICS
Qty per carton : 1 unit
W x H x D : 525 x 85 x 270 mm
Weight
: 2.0 kg
the emerging preference
Page 3
PD2800
pD2000 series
Digital Paging Microphone
PD2800 shall be suitable for large setup, offering wide range of
features with affordable pricing. Up to 108 zones can be stored
in the paging desk's memory and total capacity of zoning shall
be up to 256 zones. 9 groupings, each with 12 zones can be
programmed for paging convenience.
Multi point paging, connected in series using EX2800 would
form a large network of paging points. 3 circuits or loops are
allowed to be connected to TD6801 or TD6240 zone decoder
with priority setting.
paging microphones
Features
108 zone storage capacity with 9 programmable
groupings, each shall consist of 12 zones
Capable to page to 256 zones
One touch button for ALL CALL activation
RS485 data transmission for long distance remote paging,
decoding via TD6801 or TD6240 and zone selection via
Amperes zone selectors
Flexibility in cabling for large setup ; looping or star
Multi point paging setup with 3 priority lines
LCD display for ease of paging and programming
User selectable chime output tone
A
B
DATA IN
1
2
PR 2
G
Version :
B
DATA
A
DATA IN
PR 1
PRIORITY 2
+ -
LINE IN
G
A
B
DATA IN
ACTIVE
+ -
LINE IN
PRIORITY 1 ( HIGHEST )
G
+ -
MIC
LINE
MAINS OUTPUT
SELECT
MAINS OUTPUT
LINE / MIC
SW DIP-10
FROM
PD2800

24V DC
+
B
RS 485
24V DC
A
+
G
LINE
+
+ G
amperes

A
B
DATA IN
POWER
NORMAL
+ -
LINE IN
PR 2
G
FROM
PD2800
B
RS 485
24V DC
A
+
G
G
LINE
+
A
B
G
+ -
MIC
LINE
MAINS OUTPUT
SELECT
MAINS OUTPUT
LINE / MIC
TD6801
slave
TO
Z.SEL
Z13-24
in rack
FROM
PD2800
SW DIP-10
B
RS 485
24V DC
A
+
A
DATA IN
24V DC
B
ACTIVE
+ -
RS 485
LINE IN
G
LINE
G
PRIORITY 1 ( HIGHEST )
amperes
ACTIVE

Version :
B
+
RJ45
cable
(supplied)
+
DATA
A
+
DATA IN
A
PR 1
24V DC
B
PRIORITY 2
+ -

amperes
RS 485
LINE IN
G
LINE
max loop : 3
TD 6801
+
ACTIVE
EX2800
EX 2800
2009 : all rights reserved by amperes electronics sdn bhd
POWER
+
24V
PD2800
UNIT 4
www.ampereselectronics.com
TO
MIXER
EX2800
Size : 113 x 80 x 35 mm
Weight : 140 gms
Qty per carton : 1 unit
W x H x D : 525 x 85 x 270 mm
Weight
: 2.05 kg
NORMAL
PD2800
UNIT 3
LINE
Standard package :
1 x PD2800 paging desk
1 x EX2800 ext. connection unit
1 x 24 V DC power adaptor
1 x 1m Cat 5 cable RJ45 jack
+ -
A
LINE IN
24V DC
B
TO
Z.SEL
Z1 - 12
24V
EX 2800
packing information

amperes
RS 485
G
G
amperes
EX2800
EXT.CONNECTION UNIT
+
ACTIVE
LINE
24V DC
+
EX 2800
Loop :
normal
PR1
PR2
+ -
EX2800
TD 6801
24V
PD2800
UNIT 2
TD6801
master
3
A
4
24V DC
B
5

amperes
RS 485
6
G
7
+
ACTIVE
LINE
8
+
EX 2800
9
1300 gms ( excl. adaptor )
EX2800
12 11 10
Weight ( kg )
24V DC
PD2800
UNIT 1
TO SPEAKER ZONE SELECTOR ( REMOTE TRIGGER INPUT )
292 x 62 x 186 mm
PR ALL
400 mm
Dimensions (WxHxD)
1 2 4 8
Gooseneck mic length
in series
UNIT ADD
1 year ( internal battery )
1
Up to 1000m ( sub. to cable size )
Memory duration
2
Operating distance
application schematic
3
TD6801 / TD6240
4
RJ45 to EX2800 via Cat 5E / 6 cable
Compatible decoder
AMPERES ELECTRONICS
5
RS485 ; 19.2 KBs
Data connection
Quality Product From
MAX
6
> 60 dB at 1 KHz
Data output
MIN
7
100 ~ 12 KHz
S / N ratio
MAX
8
Frequency response
MIN
9
2 or 4 tones ; assignable
12 11 10
Chime
PD2800
Paging Microphone
TO SPEAKER ZONE SELECTOR ( REMOTE TRIGGER INPUT )
Chime and mic level
PR ALL
Line 1.2 V
Output controls
1 2 4 8
600 Ohm balanced
Output level
UNIT ADD
Output impedance
rear view
FROM
PD2800
9 groups ; each to store 12 zones
G
108
Grouping capacity
LINE
256
Zone storing capacity
A
Condenser microphone ; cardioid
Zoning capacity
B
0.42 A
Microphone
RS 485
24V DC 1A via adaptor to EX2800
Power consumption
+
Power requirement
Chime and mic volume control
24V DC
technical specifications
2 pr scr
cable
Install TD6801 and Zone Selectors
to required quantity based on
zoning size
TD6240 can be used instead of
TD6801 for 24 zone or above setup
the emerging preference
Page 4
EP1200
emergency paging panel
EP1200 is an essential paging tool for firemen during emergency, or when
direct paging to all zone is required at the equipment rack. It shall allow direct
access to the PA system which would bypass incoming BGM or other normal
paging in progress.
Its built in siren tone generator can be triggered manually via the front panel
switch or via external fire sensor or fire switch by providing a close contact to
the connector at the back of the unit.
Features
Built in siren tone generator ( constant signal )
Visual FIRE indicator
External voice message activation
Dual mode siren tone activation
Dry contact when paging mic is activated
Priority paging via front panel microphone, bypassing
technical specifications
all other audio sources
Output level controls for siren and message / paging
Power requirement
24V DC
Power consumption
3.5 W
microphone
paging microphones
Emergency Paging Mic Panel
MICROPHONE
Mic sensitivity
-72 dB Omni directional
Impedance
600 Ohm
Frequency response
300 ~ 8 KHz
application schematic
INPUTS
TRIGGER
SWITCH
SIREN
Siren frequency
Continuous at 8 KHz
Siren duration
Continuous when activated
Siren activation
Front test switch / remote contact
Input channel
Pre-amplifier output, message recorder
Output level
Balanced line out ( 1.2 V )
Priority sequence
Paging mic - siren - message - pre amp in
Indicators
Front FIRE with backlight illumination
Dimensions (WxHxD)
482 x 88 x 80 mm
Weight ( kg )
2.9 kg
OFF
CH1
CH2
CH3
CH4
CH5
CH6
SOURCE
SELECT
TONE CTRL
TUNER
OFF
MIN
MIN
SIG IN
MAX
MIN
MAX
SIG IN
MIN
MAX
MIN
SIG IN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
SIG IN
MAX
MIN
POWER
MASTER
EXT INPUT
MX 2222
MAX
MAX
CHIME
MIN
I
CASS
CD
O
AUX
MAX
MIXER
TREBLE
BASS
SIG IN
MIN
MAX
SIG IN
MUSIC SOURCE
contact
line out
MESSAGE
RECORDER
line
EP1200
MIC
TEST
FIRE
SIREN ACTIVATE
AM 6000
POWER
all call
activation
PA 2120
120 Watts
POWER AMP
POWER
PROTECT
CLIP
SIGNAL -10 dB
SIGNAL -40 dB
POWER
100V
SPEAKER
ZONE
SELECTORS
Another Quality Product From
EP1200
S/N :
MESSAGE IN
REMOTE TRIGGER
MESSAGE
SIREN
INPUT LEVEL
MESSAGE
MIN
SIREN
MAX MIN
MAX
PRE IN
ZS 5121
OVERRIDE
1
2
3
4
5
6
7
SPEAKER ZONE SELECT
8
9
10
11
12
ALL
CALL
24V
O/R
PRE OUT
VOLUME
CONTROLS
rear view
SPEAKERS
packing information
Qty per carton : 1 unit
W x H x D : 555 x 165 x 295 mm
Weight
: 3.7 kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 5
CM1400
chime unit
Chime and Siren Tone Generator
CM1400 offers 5 chimes and 2 siren tones with
selectable balanced and unbalanced line output.
Activation of chime shall be from front switches or
via remote triggering terminal, enabling the unit to
be linked to external sensors or triggering system
such as alarm panel, remote mic or emergency
switch. Siren has priority over chimes.
It is suitable for installation in schools, factories,
hazardous areas etc.
Features
application schematic
5 types of chimes and 2 siren
TIMER
Adjustable output volume
E/M SWITCH
input sources
Selectable output as balanced or unbalanced line
contact
NO
contact
CM 1400
Front panel switch activation or via remote trigger port
CM1400
POWER
CHIME
SIREN
chime input
OFF
CH1
CH2
CH3
CH4
CH5
CH6
SOURCE
SELECT
TONE CTRL
TUNER
OFF
MIN
MIN
SIG IN
MAX
MIN
SIG IN
MAX
MIN
MAX
SIG IN
MIN
SIG IN
MAX
MIN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
POWER
MASTER
EXT INPUT
MX 2122
MAX
MAX
CHIME
MIN
TREBLE
BASS
MIN
SIG IN
OTHER
INPUTS
I
CASS
CD
MAX
MIXER
SIG IN
AUX
O
MAX
MUSIC SOURCE
PRE-AMPLIFIER MIXER
technical specifications
line out
MIC
TEST
AM 6000
SIREN ACTIVATE
POWER
FIRE
E/M PANEL
Operating voltage
24V DC ; 0.5 A
Power consumption
0.3 A
Chime type
4 tone up, 4 tone down, 2 tone
Ringing bell, Westminster
TO POWER AMP, ZONE SEL, ETC
Constant siren 8 KHz
Siren type
Wavy siren
rear view
External activation
Dry contact
Output
Line 1 V
Output impedance
10 K unbalanced
Gain
+4 dB max
Dimensions (WxHxD)
482 x 44 x 90 mm
Weight ( kg )
1.6 kg
microphones
TC122
GM8
GM9
CB110
Condenser Tie Clip Mic
Condenser Gooseneck Mic
Condenser Gooseneck Mic
Handheld Mic
TC122
GM9
10m cable length with 3.5mm
lockable stereo jack
PP915
XLR Male base
Phantom Power Adaptor for TC122
GM8
Back electret condenser
Capsule
Dimension ( mm )
Weight ( gm )
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
300 - 8 KHz
-45 dB +/- 3 dB
Sensitivity
Power supply
Omni
50 ~ 16 KHz
Frequency response
Output impedance
Dynamic
Uni directional
Polar pattern
600 Ohm
CB110
-72 dB
1 K Ohm
600 Ohm
9 ~ 12V DC Phantom power supply
-
7.8 dia x 25
400
495
55 x 85
40
60
90
110
the emerging preference
Page 6
data encoder and decoder
TE6000 is used to convert analogue zone switching into RS485 data for long distance transmission of up to 1000 m. It shall also convert unbalanced signal to
balanced line output which is a preferred way of long distance audio cable run. This eliminates the need of large multicore cables which may not be economical,
inaccurate due to cable voltage drop and unwanted noise. Combination of multiple units of TE6000 shall enable large setup to be made.
TD6801 and TD6240 shall be the decoder at the receiving end for TE6000 encoder as well as Amperes PD2400 and PD2800 paging microphones. TD6801 has 12
switching outputs while its sibling TD6240 ( rack mounted ) has 24. Both accepts 3 input circuits, thus enabling multipoint paging configuration with different priority.
More than one TD6801 or TD6240 can be linked to form a large network.
Data Encoder
TE6000 :
Data Decoder
12 Ch Switching Data Encoder
12 Ch Switching Data Decoder
24 Ch Rack Mount Data Decoder
: TD6801
: TD6240
Features
Long distance switching data transmission over RS485
Converts unbalanced into balanced audio signal for minimal
noise interference in long distance cabling
Features
Expandable and addressable to cater for more zones
Priority setting for multi point paging setup
Compatible with most analogue paging microphones
Priority setting for mult point paging setup
application schematic
Selectable balanced audio output level
Compatible with most zone selectors with remote triggering port
Rack mounted or modular unit available
in rack
remote triggering port
Connect directly to ZS5601 / 5121 via remote triggering port
ZONE SELECTOR
selectors
Expandable and addressable to cater for more than 12 zone
application schematic
multi core cable
connection with PD paging mic
DIP sw. setting
for module address
to zone selector
in rack
multiply if more
zone required
TD6800
to mixer audio
input : mic/line
24V DC
2 pr scr
audio + data
<1000m
2 pr scr
TD6800
or
TD6801
priority 2
input
audio output to
mixer
24V DC
2 pr scr
TE6000
PAGING MIC
normal input
module address
setting
2 pair scr
(audio + data)
priority 1
input
2 pair scr
(audio + data)
MIC 3
priority 1
MIC 1
normal
REPEAT - PAGING MIC
If PD2400 paging mic is used,
TE6000 shall be excluded
MIC 2
priority 2
PD2400 / PD2800
paging mic
technical specifications
TE6000 / TD6801 / TD6240
Operating voltage
24V DC
AUDIO
Consumption
2.4W ( 100 mA )
Input impedance ( Ohm ) Mic : 600 ; Line : 10 K
Data protocol
RS485
Switching channels
12 / 12 / 24 with 1 priority
Output impedance
600 Ohm balanced
Baud rate
19.2 K bps
Cascade / max zones
15 / 15 / 8 ( max 192 zones )
Freq response
70 ~ 15 KHz
Input circuit
nil / 3 / 3
Audio input
Mic / Line
Output connection
Hardwired / Hardwired / RJ45
Max audio output
Line 1.1 V
DATA
Dim (W x H x D) 218 x 35 x 127 ( TE6000/6801 )
482 x 44 x 130 ( TD6240 )
Weight
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
550 g / 550 g / 1.6 kg
the emerging preference
Page 7
MX2222
pre-amplifier mixer
12 Input Pre-Amplifier Mixer
Features
12 inputs of mic, BGM sources, ext.chime and mixer link
Expandable to form more channels for larger setup
This compact 1 hu pre-amplifier mixer features 6 mic, 4 BGM
sources, chime and external line inputs and is suitable for any
application, such as meeting room, lecture theatre, hall of prayer
and definitely commercial fixed PA installation.
Auto mic muting with adjustable mixing level for mic Ch.1, 2,
ext.chime and mixer link
Priority muting with disable option for normal mixing mode
Switchable phantom power for mic channel 1 to 4
mixers / distributions
It dual output feature can be used for uninterrupted paging setup,
ie. BGM and paging announcement. Adjustable priority muting
level is available for paging announcement to override BGM and
other lower priority sources. Adjusting it to minimum and the unit
shall work like any other mixing unit and it comes with 12V
phantom power supply for mic input 1 to 4.
Dual output ; mixed line and BGM output for uninterrupted
paging setup
Independently adjustable BGM output level with balanced line
Built in daisy chain source selector with last selection memory
Bass and treble tone control
AC and DC operation for uninterrupted operation during power
failure
rear view
technical specifications
Operating voltage
230 / 240 V ac / 24 V DC
Power consumption
2.4W on 240 V ac / 100 mA on 24 V DC
Input channels
6 x mic ; 4 x BGM ; ext chime in ; mixer link
Input impedance
Mic : 600 Ohm
BGM : 47 K Ohm unbalanced
application schematic
PM1000
MIC
BGM SOURCE INPUTS
PM1060
MIC
MX2222
Chime input : 10 K Ohm unbalanced
OFF
CH1
CH2
CH3
CH4
CH5
CH6
SOURCE
Mixer link : 600 Ohm balanced
Sensitivity
Mic : 0.775 mV
TUNER
SIG IN
MAX
MIN
SIG IN
MAX
MIN
SIG IN
MAX
MIN
SIG IN
to ZS
remote trigger
MAX
MIN
SIG IN
MAX
MIN
MAX
SIG IN
MIN
MAX
Mixer : 0.7 V
Output level
MAX
CHIME
MIN
CASS
CD
amperes
AUX
MAX
MIXER
TREBLE
BASS
SIG IN
MIN
SIG IN
MAX
MUSIC SOURCE
line ou t
(mixed)
line out
(BGM)
MIC
TEST
AM 6000
POWER
TONE CTRL
OFF
MIN
MIN
BGM : 0.2 V
Chime : 0.7 V
SELECT
MASTER
EXT INPUT
MX 2222
SIREN ACTIVATE
POWER
FIRE
amperes
EP1200
1.2 V XLR balanced ( mixed output )
line
1.0 V phone jack balanced ( BGM output )
AMP - BGM
PA 2120
120 Watts
POWER
Output impedance
600 Ohm balanced
Controls
Mic channel ; chime ; mixer input
POWER
PA 2120
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
SIGNAL -40 dB
AMP- PAGING
Master mixed ; BGM ;
PA 2120
120 Watts
POWER
POWER
PA 2120
Bass and treble controls
Phantom power
12V DC switchable at mic 1 to 4
Frequency response
175 ~15 kHz ( +/- 3 dB at 1KHz) with low cut
S/N ratio
> 60 dB at 1 KHz
Dimensions (WxHxD)
482 x 44 x 180 mm
Weight ( kg )
2.55 kg
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
SIGNAL -40 dB
zone remote
trigger fr paging
mic
paging
ZONE SEL
ZS5602
BGM
ZS5602
amperes
ALL CALL
BACKGROUND MUSIC
PAGING ZONE SELECTION
TO SPEAKERS
illustration for uninterrupted paging system.
packing information
Qty per carton : 1 unit
W x H x D : 555 x 95 x 295 mm
Weight
: 3.2 Kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 8
DA2208
signal distribution amplifier
2 Input 8 Output Signal Distribution Amplifier
DA2208 consists of 2 sets of 1 in 4 out distribution amplifier with option to form 1 in 8 out unit. Each channel shall
has its own treble and bass control for better fine tuning the overall installation accordingly to type of speakers
used or the acoustic environment of the zone.
Features
Operates as dual channel 1 input 4 output or single
channel 1 input 8 output
mixers / distributions
Whenever an audio signal from pre-amplifiers are looped to too many amplifier inputs ( typically exceeding six ),
the fidelity of the original waveform would be distorted and installing a distribution amplifier shall be able to
overcome the problem.
Individual bass and treble control with volume adjustment
Direct input signal to output whenever DC power input not
application schematic
available or whenever power failure occurs
MX2222 Pre-Amplifier Mixer
technical specifications
Operating voltage
24 V DC
Power consumption
2.4W
Configuration
1 in x 8 out or 2 in x 4 out
Input level
Line : 1 V rms
Input impedance
10 K Ohm
Paging audio
signal ( Bal )
BGM audio
signal ( Bal )
DA2208 DISTRIBUTION AMPLIFIER
Balanced
output
PA 2120
1 20 W atts
Output gain
+ 4 dB
Output impedance
10 K Ohm
Controls
Bass, Treble, Channel volume
Frequency response
150 ~ 19 Khz (+\- 3dB at 1 KHz)
Dimensions (WxHxD)
4.82 x 44 x 180 mm
Amplifiers for signal
input 1 with output
from Ch 1 to 4,
Serves as Paging
amplifiers
POW ER
POW ER
PA 2120
I
PROTECT
O
S IG N A L -1 0 dB
C LIP
S IG N A L -4 0 dB
Paging Amplifiers
PA 2120
1 20 W atts
POW ER
Weight ( kg )
POW ER
PA 2120
I
PROTECT
O
S IG N A L -1 0 dB
C LIP
S IG N A L -4 0 dB
2.3
Amplifiers for signal
input 2 with output
from ch. 5 to 8
Serves as BGM
amplifiers
PA 2120
1 20 W atts
POW ER
POW ER
PA 2120
I
PROTECT
O
S IG N A L -1 0 dB
C LIP
S IG N A L -4 0 dB
BGM amplifiers
PA 2120
packing information
1 20 W atts
POW ER
POW ER
PA 2120
I
PROTECT
O
S IG N A L -1 0 dB
C LIP
S IG N A L -4 0 dB
Qty per carton : 1 unit
W x H x D : 555 x 95 x 295 mm
Weight
: 3.2 Kg
The above illustration is for Uninterrupted Paging setup. In normal setup with single input, use the link
switch to form 1 input 8 outputs configuration. Each output from DA2208 can be linked up to 6 power
amplifiers.
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 9
MxP2188
matrimix paging system
8 x 8 Matrix Paging Controller
Features
8 input and 8 output Matrix controller with inputs of either Mic
or BGM or fed from remote source panel
Individual channel setup for bass, treble and volume
Built in chime with selectable 2 or 4 tone output
Built in voice recorder of up to 60 seconds
Audio output monitor for every zone
Remote triggering port for message and siren
mixers / distributions
Priority override dry contact port whenever ALL CALL is
MxP2188 caters for a more delicate requirements of a PA
system where every zone shall have flexibility over choice
and taste of what should be listened to. It shall be able to
cater for small installations of up to 16 zones requiring full
matrix setup, such as office, club house, bungalow and
entertainment centre.
triggered
Microphone input for paging at rack
Remote paging desk connectivity to Amperes PD1160
While conventional matrix system only perform signal
routing, MxP2188 does more than that. Essential features
for a commercial PA system such as emergency overriding,
remote mic zone selection, audio monitoring, chime and
recording are available as an integral part of the unit.
rear view
application schematic
MIC
TEST
FIRE
AM 6000
PD1160 Matrix Paging Mic
EP1200
Emergency Paging Panel
EX1102 Mic Extender
F RO
M
PD
Power Amp Zone 1
1160
TO
M
IC
S PL
IT
M
A STER
TER
TO
SL
MxP2188
AVE
AX3700
C/Over
L IN E
DOWN
RP1104
Speakers
REM OTE CO NTRO L PANEL
R E M O TE S O U R C E P A N E L
L IN E
POWER
M IC
BUZZER
ON / OFF
MENU
AMP/LINE
FAULT
ALERT
UP
V O LU M E
DOWN
Amp
Zone 8
6
MENU
S/BY
UP
V O LU M E
PILOT TONE ACTIVE
M IC
Cat 5e/6
REM OTE CO NTRO L PANEL
R E M O TE S O U R C E P A N E L
M O N ITO R S P E A K E R
RP1105
Dyn Mic
3
4
5
Music Player
FAULT
NORMAL
AMP. NUMBER
AX 3700
ER1108
8 x8 M A T R IX M IX E R
M atrim ix P aging
CHANGEOVER
1
2
Mic at Controller
MxP 2188
REM OTE CO NTRO L PANEL
RP1104
REM OTE CO NTRO L PANEL
UP
MENU
UP
MENU
DOWN
REM OTE CO NTRO L PANEL
DOWN
UP
MENU
DOWN
ER1108
Matrix Overriding
Panel
Standby Amp
Cat 5e/6
Multiple unit looping
Equipment shown are for illustration of a full system.
Some items may not be required for simpler setup
technical specifications
Configuration
8 x 8 ; Cascade to 8 x 16
Output
8 x balanced line output
Power source
24V DC ; 2A via adaptor
Zone selection
Remote paging mic ( PD1160 ) ;
Inputs
8 local BGM - unbal. line or
Front panel with ALL CALL
8 remote BGM via RP1105
E/M override contact
3A dry contact
1 remote paging mic PD1160
Audio monitor
Source monitor with volume control
via 3W speaker
1 local mic input
Input connections
RJ45 (remote ) / RCA jack
Communication
RS485 ; 19.2 Kbps
XLR for local mic input
Remote triggering
Siren ( ALL CALL )
Input volume control
Manual adj. at each channel
Bass and treble control
+12 dB to -12 dB ; digital select
Dimensions (WxHxD)
482 x 88 x 300 mm
Phantom power
12V DC ( local mic in only )
Weight
6.0 kg
Priority input
Local page, E/M message
Chime
2 or 4 tone built in
Message recording
60 secs max in single bank
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
Message ( ALL CALL / individual )
packing information
Qty per carton : 1 unit
W x H x D : 555 x 165 x 295 mm
Weight
: 7.2 Kg
the emerging preference
Page 10
MxP2188 SYSTEM COMPONENTS
8 / 16 Zone Remote Paging Microphone
A dedicated remote paging desk with
8 / 16 channel zone selection,
connected directly to MxP2188
c o n t r o l l e r. To a c h i e v e m u l t i p o i n t
p a g i n g s e t u p , u s e E X 11 0 2 m i c
extender in series connection.
RP1104
800 mA
Communication
RS485 ; 19.2 kbps
Controls
Zone selection, ALL CALL
Indications
Power, signal, data, zone, busy
Mic
Condenser, cardioid
Output
Balance line output
Dimensions (WxHxD)
150 x 186 x 62 mm ( body only )
Weight
1.2 kg
Power source
24V DC via MxP2188
Power consumption
100 mA
Communication
RS485 ; 19.2 kbps
Controls
Volume, BGM source
Indications
Power, source, volume, busy
Cabling
Cat 5E / 6
Distance
Up to 1000m
Dimensions (WxH)
86 x 86 mm
Weight
100 g
Power source
24V DC via MxP2188
Power consumption
100 mA
Communication
RS485 ; 19.2 kbps
Controls
Volume
Inputs
Mic or Line (unbal.), mini jack
Cabling
Cat 5E / 6
Distance
Up to 500m
Dimensions (WxH)
86 x 86 mm
Weight
100 g
Remote Source Input Panel
RP1105 is also an upgraded version
of remote source input panel which is
t o b e u s e d t o g e t h e r w i t h R P 11 0 4 ,
installed side by side.
It allows mic or line level input source
with adjustable volume and shall be
bypassed if emergency paging is
activated at the controller.
EX1102
24V DC via MxP2188
Power consumption
Remote Zone Control Panel
RP1104 is an improved version of
remote zone controller with sensor
touch buttons and with LCD display. It
shall be installed at remote location at
individual zone and connected to the
MxP2188 controller via Cat5e / 6
cable. Each controller shall run
individually to each input port of the
respective zone.
RP1105
Power source
Paging Mic Extender
Matrix Overriding
mixers / distributions
PD1160
matrimix paging system
ER1108
When multipoint paging is required,
E X 11 0 2 s h a l l b e u s e d , w i t h e a c h
P D 11 6 0 c o n n e c t e d i n s e r i e s i n a
single circuit. The mic nearest to the
Matrix controller shall have priority
over its precedence.
MS1103
Paging Mic Splitter
EX1102 shall split incoming paging
microphone circuit into two, with one
output connected to the Master
controller while the other to the Slave
controller.
It is applicable whenever two
controllers are cascaded to form 16
channel matrix setup.
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
ER1108 is an 8 in / 8 out relay panel which would
override all individual audio signal from Matrix
controller and re-route the outputs to a single
emergency source such as EP1200 emergency
paging panel.
It is an optional item, and shall be installed after the
Matrix controller with outputs to individual amplifier
of each zone. EP1200 shall be used with
emergency trigger and audio output connected to
this unit
the emerging preference
Page 11
Ma / mb2000 SERIES MIXER AMPLIFIERS
MA2060 : 60 W 100V Mixer Amp with 3 Zone Output
MA2012 : 120 W 100V Mixer Amp with 3 Zone Output
MB2106 :
MB2112 :
60 W 100V Basic Mixer Amp
120 W 100V Basic Mixer Amp
power amplifiers
MA and MB Series of mixer amplifiers are suitable for small installations such as in showroom, small meeting hall, lecture theatre, etc. Both series are
available in 60W and 120W 100V lines, featuring 6 mic / line inputs, bass and treble controls.
MB2106 and MB2112 are basic version whereas MA2060 and MA2012 comes with 3 zone selection with remote triggering port and some additional
feature to offer greater flexibility in operation. Various protection features are incorporated in both version, such as thermal protection, short circuit cut
off and circuit breakers, providing a piece of mind in operating the unit.
Features
6 mic / line selectable input channels, with front mic jack, phantom power
6 inputs for mic and line with phantom power for input 1
Priority muting for mic input 1 with adjustable muting level
Tone and bass controls
3 zone speaker output with ALL CALL and remote triggering port
70 / 100V line output with 4 Ohm terminal with audio line output
100V line output with aux 4 ohm speaker terminal
Short circuit, thermal protections
Tone and bass controls
AC/DC operation for uninterrupted operation
AC / DC operation for fixed and uninterrupted operation
application schematic
BGM SOURCES
DYN.MIC
24V DC
B/UP SUPPLY

8 OHM SPEAKERS OR
100V SPEAKER WITH
MATCHING TRANS
REMOTE
MIC
22V
(4 ? )
COM
MAINS : 230V +/-10%
AC 50 / 60HZ
100V
(83 ? )
70V
(41 ? )
SPEAKER OUTPUT
+ 24V
+ 24V
- 24V
- 24V
DC INPUT
REC OUT
MODEL NO : MB2120
POWER OUTPUT
120W (RMS)
MA 2012
SPEAKER OUTPUT
1
2
3
ALL
CH6
CH5
LINE
LINE
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
AUDIO LEVEL
PROTECT
CH4
CH3
CH2
CH1
LINE
MIC
MIC
MIC
CH1
PHANTOM
POWER
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CH1
CH2
CH3
CH4
CH5
CH6
MASTER
BASS
MIC : 2.85mV/ 1.5K?
LINE: 285mV/ 35K?
POWER
PAGING
MIC
TREBLE
MIC
I
MIN
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
O
MAX
MAX
MIN
MAX
VOL CTRL
• • •• • • • • •
BGM SOURCES
Z1
.
FRONT INP
MICROPHONE
stereo
• • •• • • • • •
Z2
SPEAKERS
DYNAMIC / COND.
MICROPHONE
Z3
Line output to extend to
booster amplifier
technical specifications
MA2060
Rating
24V DC requirement
Current ( Load / Standby )
MB2106
Tone controls
120W 100V line
230 ~ 240V ac / 24V DC
5A
5A
8A
1.3A / 0.4A
2.2A / 0.4A
1.3A / 0.4A
2.2 / 0.4A
6 : 2 Mic ( XLR ), 4 Mic / line selectable ( RCA / phone jack )
Input sensitivity / impedance
MB2112
60W 100V line
3A
6 : 3 Mic, 1 Line ( phone jack ), 2 Line ( RCA )
Mic 1 and 2 ; 12V DC
Mic 1 switchable ; 12V DC
Mic : 2.45 mV / 2K Ohm balanced
Mic : 2.45 mV / 1.5K Ohm balanced
Line : 245 mV / 30K Ohm unbalanced
Line : 245 mV / 35K Ohm unbalanced
Input phantom power
RCA : 495mV unbalanced
RCA : 245 mV unbalanced
Bass ( 100 Hz ) ; Treble ( 10 KHz )
Bass ( 150 Hz ) ; Treble ( 10 KHz )
3 Zone 100V line, 4 Ohm
4 Ohm, 70 / 100V line
Outputs
Output selection
Frequency response
Protections
120W 100V line
230~240V ac / 24V DC
Operating Voltage
Input channel
MA2012
60W 100V line
Front and remote triggering
nil
175 ~ 18 KHz
175 ~ 15 KHz
Thermal, short circuit, AC and DC circuit breaker
Thermal, short circuit, ac fuse
AC mains, clip, protect, audio input level
AC mains, protect, audio input level
Dual speed fan with heat sensing
Dual speed fan with heat sensing
Indicators
Cooling system
Weight ( kg )
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
88 x 424 x 300 mm
88 x 424 x 300 mm
Dimensions (WxHxD)
9.9
12
8.4
the emerging preference
10.5
Page 12
PA310 :
PA320 :
PA330 :
10 W 4 Ohm Mini Amplifier
20 W 4 Ohm Mini Amplifier
30 W 100V Line Mini Amplifier
Amperes PA310 and 320 are mini amplifiers used to amplify BGM signal to a speaker of 4
or 8 Ohm, such as from TV output to a bathroom speaker in a hotel room. Amperes
VC7805 volume controller and VP7810 BGM-Speaker patch panel can be installed if
required to allow emergency paging to be announced at the speaker.
Features
Other applications include simple mic calling system at counters or as an amplifier module
to some other system which need to broadcast audio output to a speaker, ie. queue
management system or telephone intercom.
Available in 10 or 20W 4 Ohm rating or 30W 100V line
Adjustable volume control for volume preset
Compact size for easy installations
application schematic
power amplifiers
pa300 series mini amplifiers
24V DC
OVERRIDE
SIGNAL
(optional)
FROM
TV SOURCE
(line in)
8OHM
SPEAKER VOLUME
2
1
OFF
-
LINE IN
INPUT
POWER
amplifier module
amperes electronics
+
+
OUTPUT
PA305
 
VC7805
-
TO SPEAKER
VOLUME ADJ
4
5
OVERRIDE
AC INPUT
3
VP7810
8 OHM
SPEAKER
PA310
PA305 MINI AMP
PA320
PA330
Amperes PA330 has higher rating of 30W 100V line which
accepts unbalanced line input. It can be used as remote
amplifier in a decentralised PA system. Among applications
include classroom paging and paging for remote station.
Using TS6100 ( step down module ) shall allow PA330 to
accept 100V line input and thereby a very large network of
paging can be implemented in a wider area.
technical specifications
PA310
Rating
10W 4 Ohm
PA330
20W 4 Ohm
30W 100V Line
230~240V ac
Operating Voltage
Current consumption
PA320
0.06A
0.14A
40 mV
Input sensitivity
1.2 V
Max input
150 K Ohm
Input impedance
150 - 15 KHz
Input volume preset
Controls
Power LED
Indications
Weight ( kg )
10 K Ohm
100 - 18 KHz (+/- 3 dB)
Frequency response
Dimensions (WxHxD)
0.17A
Mono ; unbalanced line
Input signal
103 x 45 x 91
103 x 54 x 101
480 g
700 g
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
160 x 95 x 170
2.9 kg
no standard packing available
the emerging preference
Page 13
power amplifiers
pa2000 series power amplifiers
PA2120
PA2240
PA2360
PA2480
:
:
:
:
120W 100V
240W 100V
360W 100V
480W 100V
Amperes PA series of power amplifiers had been the workhorse of many
installations and are available in power ratings of 120W to 480W 70 / 100V line.
Various features had been added throughout the years since its inception and
these had enhanced their performance and reliability.
Amperes AS4000 / AX700 can be used alongside with PA series of amplifiers to
form an automatic amplifier fault changeover setup or to be much simpler,
Amperes AX3700 is recommended to serve the same purpose.
Features
Available in various ratings ; from 120W to 480W 70 or
100V line
4 Ohm speaker connection available with 25V output
Thermal protection by muting input signal ( typically 85
deg at heat sink )
Momentary short circuit protection
Temperature dependent dual speed cooling fan
Manual reset circuit breaker for AC mains and DC input
PP2240 / 2360 / 2480
Balanced input signal with gain control and selectable
grounding option
AC and DC operation for uninterrupted operation during
power failure
PP2120
technical specifications
PA2120 / PA2240 / PA2360 / PA2480
Power requirement
230 / 240 V ac ( 24V DC backup )
24V DC requirement
8A / 19A / 23A / 29A
Pwr consumption (load) ac
1.4A / 3A / 3.4A / 4.5A
Pwr consumption ( s/by )
0.4 A
Input sensitivity
1 V / 10 K Ohm
Input gain control
-15 dB ~ 0 dB
Input connection
XLR balanced line input
Rated output ( rms )
120W / 240W / 360W / 480W 100V line
Output voltage ( 4 Ohm )
22 / 31 / 38 / 44 V rms
Output imp ( 70 V line )
42 / 21 / 13 / 10.2
application schematic
24V DC
battery backup
Output to
speakers or
zone selectors
parallel to
next amplifier
TM
MODEL NO : PA2240
POWER AMPLIFIER
240W (RMS)
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
CAUTION
( 100 V line )
83 / 42 / 27.8 / 20.8
Frequency response
180 ~ 17 KHz (+/- 3dB at 1 KHz) with low cut
S / N ratio
> 60 dB ( @ 1KHz )
Protections
Thermal, momentary output short circuit, AC and
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
From pre-amplifier
Loop to next amp in.
DC circuit breaker, Input signal clip
Indicators
AC mains, Clip, Protect, Input level
Cooling system
Dual speed fan with heat sensing
Dimensions (WxHxD)
PA2120 : 88 x 482 x 300 mm
PA2240 / 2360 / 2480 : 133 x 482 x 300 mm
Weight ( kg )
rear view PA2240 / 2360 / 2480
11.0 / 20.5 / 21.2 / 25.1 kg
packing information
Qty per carton : 1 unit
W x H x D : PA2120 : 550 x 215 x 420 mm
PA2240 / 2360 / 2480 : 550 x 215 x 420 mm
Weight
: PA2120 - 12.2 kg
PA2240 - 21.8 kg
PA2360 - 22.5 kg
PA2480 - 26.4 kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
rear view PA2120
the emerging preference
Page 14
PX2100
PX2200
PX2300
PX2400
PX series of power amplifiers are equipped with AFS ( Auto Fault Sensor ) which
generate pilot tones internally and automatically diagnose and detect any faulty
condition that may occur at the output end. Pilot tones are generated at intervals
to avoid straining the power packs, and this shall prolong the life span of the units.
PX series of amplifiers shall be linked to Amperes AX700 changeover unit for
standby amplifier takeover in the event a duty unit fails, enabling automatic
amplifier fault changeover setup.
:
:
:
:
120W 100V
240W 100V
360W 100V
480W 100V
Features
Incorporating Auto Fault Sensing ( AFS ) circuitry for self
monitoring of its output
Pilot tone switchable for normal operation without AFS
power amplifiers
px2000 series power amplifiers with auto fault sensing
Interval PT generation to avoid continuous loading of the
amplifier
Thermal protection by muting input signal ( typically 85 deg
at heat sink )
Temperature dependent dual speed cooling fan
Manual reset circuit breaker for AC mains and DC input
Balanced input signal with gain control and selectable
grounding option
PX2200 / 2300 / 2400
AC and DC operation for uninterrupted operation during
power failure
technical specifications
application schematic
PX2100 / PX2200 / PX2300 / PX2400
Power requirement
230 / 240 V ac ( 24V DC backup )
24V DC requirement
8A / 19A / 23A / 29A
Pwr consumption (load) ac
1.4A / 3A / 3.4A / 4.5A
PX 2200S
PX SERIES
STANDBY
Pwr consumption ( s/by )
0.4 A
Input sensitivity
1 V / 10 K Ohm
Input gain control
-15 dB ~ 0 dB
Input connection
XLR balanced line input
Rated output ( rms )
120W / 240W / 360W / 480W 100V line
Output voltage ( 4 Ohm )
22 / 31 / 38 / 44 V rms
Output imp ( 70 V line )
42 / 21 / 13 / 10.2
240 Watts
POWER
POWER
AUTO FAULT SENSING
PROTECT
ON
CLIP
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
WITH AUTO FAULT SENSING
PX SERIES
DUTY 6
PX 2200S
240 Watts
POWER
POWER
AUTO FAULT SENSING
PROTECT
ON
CLIP
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
WITH AUTO FAULT SENSING
( 100 V line )
Frequency response
Trigger
Contact
83 / 42 / 27.8 / 20.8
180 ~ 17 KHz (+/- 3dB at 1 KHz) with low cut
Trigger
Contact
PX SERIES
DUTY 1
PX 2200S
240 Watts
S / N ratio
> 60 dB ( @ 1 Khz )
Protections
Thermal, momentary output short circuit, AC and
POWER
POWER
AUTO FAULT SENSING
PROTECT
ON
CLIP
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
100V
WITH AUTO FAULT SENSING
DC circuit breaker, Input signal clip
Indicators
AC mains, Clip, Protect, Input level, Pilot tone, Fault
Cooling system
Dual speed fan with heat sensing
100V
6
Cascade
link
FAULT DETECTION
10 seconds
100V
ZONE
SELECTOR
Detection response
15 - 25 seconds
Detection method
Internal Pilot Tone generated at 20 kHz
Failure recovery time
20 seconds max
Failure output
Dry contact ( NO at 3A rating )
Dimensions (WxHxD)
PX2100 : 88 x 482 x 300 mm
ZS 5121
OVERRIDE
1
2
4
5
6
7
SPEAKER ZONE SELECT
8
9
10
11
12
ALL
CALL
100V
TO VOL CTRL / SPEAKERS
100V
(42 ? )
COM
31V
(4 ? )
+ 24V
SPEAKER OUTPUT
- 24V
- 24V
DC INPUT
DO NOT BLOCK VENT
THIS EQUIPMENT REQUIRES
ADEQUATE VENTILATION
11.1 / 20.6 / 21.3 / 25.4 kg
70V
(21 ? )
PX2200 / 2300 / 2400 : 133 x 482 x 300 mm
Weight ( kg )
3
+ 24V
Detection interval
1
AX700
PRESS TO RESET
BREAKER
DC 15A
AC 5A
PX2200S
MAINS : 230V +/-10%
AC 50 / 60HZ
packing information
BALANCED INPUT
1V / 10K ?
INPUT
PILOT TONE
rear view : PX2200 / 2300 / 2400
ON
LINK
GROUND LIFT
OFF
FLOAT
FRAME
TO AX700
Qty per carton : 1 unit
W x H x D : PX2100 : 550 x 175 x 420 mm
PX2200 / 2300 / 2400 : 550 x 215 x 420 mm
Weight
: PX2100 - 12.3 kg
PX2200 - 21.9 kg
PX2300 - 22.6 kg
PX2400 - 26.7 kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
rear view : PX2100
the emerging preference
Page 15
AC3601
6 Duty / 1 Standby Amplifier Changeover Panel
manual amplifier changeover
Amperes AC3601 is a manual changeover panel for 6 duty with 1 standby amplifier and is
required for a standby unit to take over a failed duty amp to ensure uninterrupted and
continuous operation of a PA system. More than one AC3601 can be cascaded for a single
standby unit to cater for more than 6 duty packs.
amplifier changeover & monitoring
Protection circuitry is embedded that only allows one failed duty amplifier to be taken over by
standby unit to prevent overloading. Priority features shall ensure higher numbered failed unit
has preference for changeover.
application schematic
Features
Cater for 6 duty and 1 standby amplifier
Expandable for 1 standby to serve more than 6 duty units
Overload protection by allowing only a single take over
Prioritized changeover - unit with higher number is
preferred for changeover
Manual front panel changeover selection
technical specifications
Operating voltage
24V DC via PS9400 PSU
Power consumption
Standby : 82 mW, 3.4 A
Operating : 1.3 W, 50 mA
Zone load rating
400 W / 100V line per ch.
Amplifier inputs
6 duty / 1 standby
Changeover indication
Front switch LED
Switching mode
Via front panel switch
Cable connection
Plug in connectors
Cable size
2.5 mm sq
Dimensions (WxHxD)
482 x 44 x 130 mm
Weight
2.0 kg
rear view
packing information
Carton : 555 (W) x 95 (H) x 295 (D) mm
Weight : 2.60 kg
: 1 units / carton
Qty
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 16
AX700
auto amplifier changeover
6 Duty / 1 Standby Amplifier Changeover Panel
AX700 is a platform for standby amplifier to take over failed duty unit in an automated changeover setup. Each unit
caters for 6 duty and 1 standby amplifier but expandable to larger setup with a single standby power pack.
It shall be used with amplifiers with auto fault sensing ( AFS ) such as PX series and whereas normal amplifiers are
used, Amperes AS4000 shall be installed at every duty unit. In such case, we recommend that Amperes AX3700 to
be used instead.
Features
application schematic
Cater for 6 duty and 1 standby amplifier
Expandable for 1 standby to serve more than 6 duty units
Overload protection by allowing only a single take over
Application with AS4000 amplifier surveillance module
Prioritized changeover - unit with higher number is preferred
for changeover
FROM PRE-AMP MIXER
DUTY AMP 1
A+PT
PA 2120
120 Watts
POWER
trigger
AMP/ LINE FAULT
PROTECT
SIGNAL -10 dB
amperes
CLIP
PT TRANSMIT
DC24V +
DC24V -
SIGNAL -40 dB
AMP +
AMP RLY NO
RLY NC
RLY COM
SIG OUT SIG OUT +
GND
SIG IN +
SIG IN -
amperes electronics
100V
100V
A - Audio
PT - Pilot Tone
DUTY AMP 6
AS400 amplifier line surveillance module
PA 2120
trigger
WARNING :
To be used with PA amplifier of 70/100V line only
Use recommended power supply only
Ensure correct power polarity
120 Watts
POWER
POWER
PA 2120
AMP/ LINE FAULT
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
PT TRANSMIT
DC24V +
DC24V -
SIGNAL -40 dB
AMP +
AMP RLY NO
RLY NC
RLY COM
SIG OUT SIG OUT +
GND
SIG IN +
SIG IN -
amperes electronics
100V
AS400 amplifier line surveillance module
PA 2120
WARNING :
To be used with PA amplifier of 70/100V line only
Use recommended power supply only
Ensure correct power polarity
120 Watts
POWER
POWER
PA 2120
trigger
AMP/ LINE FAULT
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
PT TRANSMIT
SIGNAL -40 dB
DC24V +
DC24V -
TO ZONE SELECTOR, VC,
SPEAKERS
I
O
Compatible with most auto detection cards
AX700
AS400 amplifier line surveillance module
WARNING :
To be used with PA amplifier of 70/100V line only
Use recommended power supply only
Ensure correct power polarity
POWER
PA 2120
Fault alert with LED indicator and switchable buzzer
AS4000
technical specifications
Operating voltage
24V DC via PS9400 PSU
Power consumption
Standby : 82 mW, 3.4 A
Operating : 1.3 W, 50 mA
AMP +
AMP -
amperes electronics
STANDBY AMP
RLY NO
RLY NC
RLY COM
SIG OUT SIG OUT +
GND
SIG IN +
SIG IN -
AS4000 for standby
amp optional
amplifier changeover & monitoring
AX700 has protection features that only allow a single takeover to prevent overloading.
Zone load rating
400 W / 100V line per ch.
Amplifier inputs
6 duty / 1 standby
Indications
Red LED for takeover
Green - normal / non c/over
Switching mode
AS4000 / other contacts
PX AMPLIFIER 1
100V
PX 2100
amperes
120 Watts
PROTECT
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
amperes
ON
CLIP
trigger
CASS
SELECT
CD
MUSIC SOURCE
TUNER
OFF
MAX
MIN
MASTER
SIG IN
BASS
TONE CTRL
MAX
MIN
MAX
CHIME
EXT INPUT
MIXER
TREBLE
100V
SIG IN
PX 2100
120 Watts
POWER
MIN
MIN
CH2
MAX
MIN
CH3
MAX
MIN
SIG IN
CH4
MAX
SIG IN
CH5
MAX
SIG IN
CH6
MAX
MIN
SOURCE
AX700
SIG IN
MAX
MIN
audio input
PX 2100
AUTO FAULT SENSING
PROTECT
O
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
amperes
ON
CLIP
SIG IN
trigger
MX 2122
MIN
CH1
MAX
MIN
SIG IN
POWER
I
PX AMPLIFIER 6
MIXER
100V
PX 2100
TO ZONE SELECTOR, VC,
SPEAKERS
AUTO FAULT SENSING
I
O
AUX
I
O
POWER
PX 2100
OFF
Changeover alert
Buzzer, LED
Changeover section
Amplifier outputs only
Cable connection
Plug in connectors
Cable size
2.5 mm sq
Dimensions (WxHxD)
482 x 44 x 130 mm
Weight
2.0 kg
POWER
POWER
INPUTS
Dry contact activation by
120 Watts
POWER
POWER
PX 2100
AUTO FAULT SENSING
I
PROTECT
O
SIGNAL -10 dB
AMP FAULT
SIGNAL -40 dB
PILOT TONE
amperes
ON
CLIP
trigger
STANDBY AMP
packing information
cascade AX700 if required
Carton : 555 (W) x 95 (H) x 295 (D) mm
Weight : 2.60 kg
Qty
: 1 units / carton
Application using PX series of amplifiers with AFS
IN
PLEASE OBSERVE POLARITY
OUT
HOT
COM
HOT
COM
COM
HOT
HOT
HOT
COM
STANDBY
AMP INPUT
COM
HOT
COM
HOT
HOT
COM
HOT
COM
COM
COM
HOT
HOT
6
HOT
5
COM
4
COM
3
COM
2
S/BY
1
COM
+
DUTY AMPLIFIER INPUTS
HOT
AUTO AMP. CHANGEOVER
rear view
AMP.FAULT DETECT TRIGGER
DC 24V
0.5 A
DUTY AMP
S/BY AMP
IN
OUT
LINK TO AS400
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
TO
COM
AS400 1~6
AMP.IN
AMP.OUT
S/BY IN
TO ZONE SELECTOR
OR SPEAKERS
AX700 WIRING CONNECTIONS
AMP. IN - FR. AMP OUTPUTS
AMP. OUT - TO ZONE SELECTOR / SPEAKERS
MAX LOAD / CH - 400W / 100V LINE
LINK
Quality Product From
DETECT
AX700
AMPERES ELECTRONICS
the emerging preference
Page 17
AX3700
auto amplifier changeover
6 Duty / 1 Standby Auto Amplifier Changeover Panel
Amperes AX3700 offers a great flexibility and simplicity in cabling for auto amplifier fault changeover system with its combination of amplifier
fault sensor modules and changeover panel in a box. The internally generated Pilot Tone and sensory circuit shall detect any faulty duty
amplifier and would initiate a changeover process.
AX3700 has been optimised for faster fault detection and changeover as compared with AS4000 modules. Pilot tones are generated at
intervals to avoid constant loading of power amplifiers.
amplifier changeover & monitoring
Changeover are performed at both input and output sections, making it suitable for application in a matrix system. At any one time, only a
failed duty unit shall be replaced by a standby amp, to avoid overloading.
technical specifications
Features
Cater for 6 duty and 1 standby
Operating voltage
24V DC 1 A via PS9400 PSU
Expandable for 1 standby to cater for more than 6 duty amps.
Power consumption
7.2 W
Built in Pilot Tone generator, transmit at intervals and senses at
Input signal
6 ch. balanced line signal
sequence to protect amplifiers
Input impedance
10 K Ohm
Overloading protection by allowing only a single take over
Audio output gain
Unity
Prioritised changeover which higher numbered amplifier shall be
Pilot tone interval
10 secs / channel
preferred for take over if more than two units are down
Pilot tone frequency
20 KHz ( +/- 5% )
Shorter fault detection time from 10 to 25 seconds
Detection line
70 / 100 V line
Changeover at input and output section simultaneously ; suitable
Detection level
50 V rms
for matrix system installations
Failure detection time
10 ~ 25 seconds
Input link switch ; making connection of sources easier
Failure recovery time
20 seconds max
Channel isolation switch for unused or un-monitored channel
Zone load rating
400W / 100V line
Individual channel status indicators ; normal, fault and changeover
Status indications
Normal ; Fault ; Changeover
Changeover alert
Buzzer with switch
Changeover section
Input and Output simultaneously
Dimensions (WxHxD)
482 x 88 x 150 mm
Weight
3.4 kg
application schematic
INPUT SOURCES
OFF
MAX
MIN
MAX
SIG IN
MIN
CH6
MAX
MIN
SIG IN
SOURCE
MAX
SIG IN
MIN
SELECT
POWER
MASTER
MAX
CHIME
MAX
TONE CTRL
MIN
I
CASS
CD
O
AUX
MAX
MIXER
TREBLE
BASS
MIN
SIG IN
MUSIC SOURCE
24V DC
overriding
MIC
TEST
FIRE
SIREN ACTIVATE
AM 6000
POWER
audio
DUTY AMP
PROTECT
SIGNAL -10 dB
NORMAL
POWER
100V
AMP/LINE
FAULT
ALERT
PILOT TONE ACTIVE
FAULT
AX 3700
CLIP
6
7
SPEAKER ZONE SELECT
120 Watts
POWER
I
O
VOL
CTRL
1
AX3700
PA 2120
POWER
PA 2120
ZONE
SELECTOR
MAX
SIG IN
ALL
CALL
E/M
PANEL
MIN
SIG IN
12
CH5
TUNER
MAX
11
CH4
OFF
MIN
SIG IN
10
CH3
EXT INPUT
MAX
9
CH2
MIN
MIN
SIG IN
8
CH1
MX 2122
CHANGEOVER
AMP. NUMBER
1
2
3
4
5
6
S/BY
BUZZER
ON / OFF
4
5
SIGNAL -40 dB
OVERRIDE
1
2
3
1
100V
6
s/by
ZS 5121
6
audio +
PT
DUTY AMP
SPEAKERS
PA 2120
120 Watts
POWER
POWER
PA 2120
I
PROTECT
O
SIGNAL -10 dB
CLIP
24V DC
overriding
SIGNAL -40 dB
100V
packing information
PA 2120
120 Watts
POWER
POWER
PA 2120
I
PROTECT
O
SIGNAL -10 dB
CLIP
SIGNAL -40 dB
100V
STANDBY
AMP
rear view
Carton : 555 (W) x 165 (H) x 295 (D) mm
Weight : 4.2 kg
Qty
: 1 units / carton
AUDIO SIGNAL INPUTS / OUTPUTS
AX3700
AMP. AUTO
FAULT
CHANGE OVER
Cascade AX3700 is more than 6 duty
amps are installed
CHANNEL 6
+
-
SIGNAL
LINK
INPUT
OUTPUT
G
+
-
CHANNEL 5
-
G
+
CHANNEL 4
SIGNAL
LINK
INPUT
OUTPUT
LINK OPEN +
-
+
-
G
+
CHANNEL 3
SIGNAL
LINK
INPUT
OUTPUT
LINK OPEN
-
INPUT
OUTPUT
LINK OPEN
+
-
G
+
-
SIGNAL
LINK
CHANNEL 2
INPUT
OUTPUT
LINK OPEN +
-
G
+
-
SIGNAL
LINK
CHANNEL 1
OUTPUT
LINK OPEN +
-
INPUT
G
+
-
STANDBY FAULT
CONT.
OUTPUT
3A NO
MAX
+
- G
INPUT SIGNAL
DO NOT SWITCH TO LINK WHEN DIFFERENT AUDIO
SOURCES ARE USED FOR THE ADJACENT CHANNEL
CHAN. 1
ON
CHAN. 2
ON
CHAN. 3
ON
CHAN. 4
ON
CHAN. 5
ON
SWITCH TO OFF FOR UNUSED CHANNEL
AMPLIFIER 70/100V LINE INPUTS/OUTPUTS
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
CHANNEL / AMP. DETECTION SWITCHES
CHAN. 6
ON
HIGH
CASCADE RS 485
LOW
IN+
STANDBY
AMP
IN-
IN-
IN+
OUT+
CHANNEL 1
OUT-
IN-
IN+
OUT+
CHANNEL 2
OUT-
IN+
IN-
OUT+
CHANNEL 3
OUT-
IN -
OUT -
OUT +
IN+
CHANNEL 4
IN +
IN-
OUT+
CHANNEL 5
OUT-
IN+
IN-
OUT-
OUT+
CHANNEL 6
DC 24V
0.5 A
+
-
A
B
AMP CONNECTIONS
IN +/- --> FR. AMP OUTPUTS
OUT +/- --> TO ZONE SELECTOR / SPEAKERS
MAX LOAD / CH - 400W / 100V LINE
CASCADE
CONNECT ONLY ONE WIRE FOR CASCADE TO NEXT
UNIT
UNIT 1(LOW) --- UNIT 2(HIGH)
PLEASE OBSERVE POLARITY
the emerging preference
Page 18
AM6000
amplifier monitoring
6 Ch. Amplifier Monitor Panel
AM6000 shall be used to monitor the condition of amplifier outputs of 70 / 100V
line at the rack which is equipped with level meter, amplifier output LED and
speaker for audio monitoring. It can also be used as a tool to calibrate sound
output level of each amplifier from the rack.
Features
6 inputs for 70 / 100 V line amplifier outputs
Dual mode monitoring with continuous signal indicator
technical specifications
rear view
AMPLIFIER INPUTS
COM
COM
AMP 6
100V
COM
AMP 5
100V
COM
AMP 4
100V
AMP 3
100V
-
COM
+
AMP 2
COM
AMP 1
100V
24V,1A
100V
AM 6000
DC SUPPLY
Operating voltage
24V DC via PS9400 PSU
Power consumption
50 mW
Amplifier inputs
6 : 70 / 100V line
Monitoring mode
Audio : 1 W speaker with 5 presets
AMPLIFIER MONITOR PANEL WIRING DIAGRAM
Visual : 9 segment LED level meter
AMP IN - FROM AMPLIFIER OUTPUT
PLEASE OBSERVE LINE POLARITY
AMP IN 1
AM 6000
LED for all channels
AMP IN 6
AMP 1
CAUTION : PLEASE OBSERVE POLARITY
TO ZONE SELECTOR / SPK
AMP 6
Dimensions (WxHxD)
482 x 88 x 130 mm
Weight
2.3 kg
packing information
Carton : 555(W) x 165(H) x 295(D) mm
Weight : 3.1 kg
Qty
: 1 units / carton
AS4000
Amplifier Surveillance Module
amplifier changeover & monitoring
Audio monitoring with volume control
AS4000 is used to monitor the status of 70 / 100 V line power amplifiers
which do not have built in detection module. Every amplifier shall
employ one AS4000 and the dry contact output from the unit shall then
be connected to Amperes AX700. Repeating this link shall then form an
automatic amplifier fault changeover / surveillance system.
Features
technical specifications
Interval Pilot Tone injection ; reduces strain to amplifiers
Operating voltage
24V DC via PS9400 PSU
Works independently with or without availability of audio signal
Power consumption
200 mW nominal
Low distortion to original audio signal
Input impedance
10 K balanced
Status monitoring via LED ; Pilot Tone and amplifier fault
Output impedance
600 Ohm balanced
Compatible with most 70 / 100 V line amplifiers in the market
Max audio input
0.75 V
Max audio output
1.2 V
Transmit interval
10 seconds
Detection delay
20 seconds
Recovery time
30 seconds
Frequency response
20 - 20 KHz
Detection output
NO and NC dry contact
Dimensions (WxHxD)
120 x 96 x 28 mm
Weight
330 gms
application schematic
Please refer to schematic in AX700 ; “ Application
with AS4000 amplifier surveillance module “
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 19
6 Ch Speaker Line Surveillance
LS4600
Features
LS4600 monitors the condition of speaker line for faults such as ground
leakage, short circuit and open circuit. It employs impedance measurement
method with detection tone, and this would eliminate the use of blocking
capacitors and resistors in the speaker network. Upon detection of flaws, it
would provide fault alert via LED indications and buzzer.
6 channel speaker line monitoring and expandable
Basic and Advance level of detection setup
Detection of faulty cable and speaker in individual zone or circuit
Impedance measurement method - no capacitor coupling
required and cable branching allowed.
This improved LS4600 ( version 2 ) has wider detection range as compared to
its predecessor, from 10 Ohm to 10 KOhm. Other added features included are
two level of detection setup - basic and advance, circuit fault disconnection
option, improved accuracy and stability.
Faulty circuit disconnection option
Built in impedance meter, range within 10 Ohm to 10 KOhm
LCD display to facilitate system setup, measurement and
monitoring
Fault alert with LED indicators and switchable buzzer
Detection test interval setting from 1 min to 48 hours
technical specifications
Short burst test signal, minimizing interruption to PA operation
User setting for detection sensitivity for open, short and leakage
Operating voltage
24V DC via PS9400 PSU
Aux 24V DC output for volume controller overriding during
Power consumption
3.5 W
testing mode
Capacity
6 channel and expandable
Processor
PIC microcontroller with 12 bit ADC
Impedance detection range
10 to 10 K Ohm
Power measurement range
3 to 1000 W 100V line
Measurement accuracy
+/- 3% within range
Pilot tone injection frequency
1 KHz
Pilot tone signal output level
5V sine
Transmittal detection period
3 seconds per channel
Detection interval
User preset from 1 min to 48 hrs
Sensitivity setting
User preset at each channel
Indicators - LED
Normal, Fault, Buzzer, Auto run
Display LCD
2 x 16 characters sigh back light setting
Audible output signal
Continuous buzzer with Off option
Dry contact setting
3A
DC output in detection mode
24 V DC for individual channel
Dimensions (WxHxD)
482 x 44 x 130 mm
Weight
2.3 kg
amplifier changeover & monitoring
speaker line monitoring
rear view
application schematic
ZONE
SELECTOR
LS4600
SPEAKER
100V
1
2
3
10
4
5
6
11
12
1
2
3
4
5
6
ALL
CALL
240 Watts
PX 2200S
POWER AMP
4
3
2
1
6
7
SPEAKER ZONE SELECT
5
AMP FAULT
PILOT TONE
ON
SIGNAL -10 dB
AUTO FAULT SENSING
CLIP
5
6
8
9
PATCH
PANEL
SPEAKER
PATCH PANEL
4
SPEAKER VOLUME
3
4
3
5
2
OVERRIDE
OVERRIDE
1
SIGNAL -40 dB
WITH AUTO FAULT SENSING
PROTECT
POWER
2
1
OFF
E/M
OVERRIDE
POWER
VOL CTRL
SPEAKER VOLUME
VR 7000
ZS 5121
2
1
OFF
3
4
5
packing information
OVERRIDE
multiply LS4600
as required
VR7000
24V emergency
override signal
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
24V
24V O/RIDE
Carton : 555(W) x 165(H) x 295(D) mm
Weight : 2.9 kg
Qty
: 1 units / carton
the emerging preference
Page 20
speaker zone selector
6 Ch Speaker Zone Selector
12 Ch Speaker Zone Selector
: ZS5601
: ZS5121
ZS5601 and 5121 are trusted product for
speaker zone selection which had been
used for nearly a decade.
They provide direct zone switching for
single source PA setup via front panel
switches or through remote port
connected to Amperes PM Series paging
desk, or through Amperes TD decoders
when PD series of paging desks are
used. Other mades of paging consoles
are compatible with ZS provided they
have negative triggering switching ports.
A distinctive feature shall be the remote
override function which bypasses local
zone selection whenever a paging mic
connected to it is activated. The
individual input and output connections
make
it
flexible
for
amp-zone
configurations as well as for matrix setup.
Features
Available in 6 ( ZS5601 ) and 12 zone ( ZS5121 ) respectively with ALL CALL
Expandable to more zones as required
selectors
Remote zone triggering port via external paging microphone or console
Paging override by Amperes paging console with Priority override indicator
Emergency paging mic triggering port with dry contact for volume controller
overriding application
Flexible amplifier to zone configuration
technical specifications
Operating voltage
24V DC ; 0.5 A
Power consumption
ZS5601 : 3.5W , 0.14A w ALL CALL
application schematic
POWER AMPLIFIERS
(70/100V)
ZS5121 : 6.8W , 0.28A w ALL CALL
Max load / channel
400W at 100V line
Number of zones
6 ( ZS5601 ) ; 12 ( ZS5121 )
Amplifier inputs
6 ( ZS5601 ) ; 12 ( ZS5121 )
Zone selection
Front panel switch and remote
Cascade limitation
Unlimited
Remote triggering
- ve triggered ( common ground )
Indicators
Individual zone switch, Priority
Switching mode
Individual, ALL CALL
POWER AMPLIFIER
POWER
24V DC REG.
POWER
AC INPUT
DC OUTPUT
PROTECTION
PROFESSIONAL PA SYSTEM
E/M PANEL TRIGGER
OR OTHER
TRIGGERING
METHOD
P IN 1-Z 7
P IN 2-Z 8
P IN 3-Z 9
P IN 4 -Z 10
P IN 5 -Z 11
P IN 6 -Z 12
P IN 7-A C
P IN 8 -G N D
ZS5601
OR
ZS5121
MIC
TEST
AM 6000
P IN 1-Z 1
P IN 2-Z 2
P IN 3-Z 3
P IN 4-Z 4
P IN 5-Z 5
P IN 6-Z 6
P IN 7-A C
P IN 8-P R
SIREN ACTIVATE
POWER
FIRE
amperes
Local zone selection bypassed when
for E/M override
remote trigger is activated
Dimensions (WxHxD)
482 x 44 x 130 mm
Weight
1.8 kg ( ZS5601 ) ; 1.9 kg ( ZS5121 )
Dry contact for link to other
application / EM overriding
packing information
TO SPEAKERS ( VARIOUS
ZONES )
N+3 Multicore Cable
N= No of Zones
remote zone trigger
Carton Size : 555 (W) x 95 (H) x 295 (D) mm
Weight
: ZS5601 : 2.4 kg
: ZS5121 : 2.5 kg
Qty
: 1 units / carton
rear views
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
AMPERES PM1060 / 1120 REMOTE
PAGING
MICROPHONES ( OR OTHER BRANDS
WITH NEGATIVE TRIGGER )
PIN 1-Z1
PIN 2-Z2
PIN 3-Z3
PIN 4-Z4
PIN 5-Z5
PIN 6-Z6
PIN 7-AC
PIN 8-PR
PIN 1-Z7
PIN 2-Z8
PIN 3-Z9
PIN 4-Z10
PIN 5-Z11
PIN 6-Z12
PIN 7-AC
PIN 8-GND
the emerging preference
Page 21
speaker zone selector
ZS5602
6 Ch Uninterrupted Paging Speaker Zone Selector
ZS5602 shall be suitable for uninterrupted paging setup, ie. when
an announcement to a zone is made, other areas with BGM shall
not be interrupted.
This shall require two sets of amplifiers connected to the ZS5601,
thus the system shall consist of two sources, one being BGM and
the other as Paging.
Similarly to ZS5601 / 5121, paging zone can be remotely triggered
and each zone shall have separate amp input - zone output
terminals, thus making it flexible for amp-zone configuration.
application schematic
REMOTE PAGING
MICROPHONE
Features
BGM SOURCES
MIXER MX2222
Available in 6 zones for BGM and 6 for Paging with ALL CALL
OFF
CH1
CH2
CH3
CH4
CH5
CH6
SOURCE
SELECT
TONE CTRL
TUNER
OFF
MIN
MAX
CHIME
MIN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
MAX
SIG IN
Remote zone triggering port via external paging mic
MIN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
MAX
SIG IN
MIN
POWER
MASTER
EXT INPUT
MX 2122
Expandable or link multiple units to form more zones
MIN
I
CASS
CD
O
AUX
MAX
MIXER
TREBLE
BASS
MAX
MIN
SIG IN
MAX
SIG IN
MUSIC SOURCE
BGM
Emergency paging mic triggering port with dry contact for
Paging
PAGING AMPLIFIERS
BGM AMPLIFIERS
volume controller overriding application
PA 2060
PA 2060
60 Watts
60 Watts
POWER
POWER
POWER
AM 6000
I
PROTECT
O
SIGNAL -10 dB
POWER
AM 6000
CLIP
I
PROTECT
O
SIGNAL -10 dB
CLIP
SIGNAL -40 dB
Aux DC output for selected paging zone
SIGNAL -40 dB
Suitable for 3 or 4 wire system
Paging output
BGM output
Quality Product From
AMPERES ELECTRONICS
-VE TRIGGER
( OR 3 WIRE SYSTEM PRIORITY ZONE OUTPUTS )
PLEASE OBSERVE POLARITY WHEN CABLING
AMP6
ZON6
100V
100V
100V
COM
ZON5
COM
AMP5
COM
ZON4
COM
AMP4
COM
ZON3
COM
AMP 3
100V
ZON2
COM
AMP 2
COM
ZON1
100V
BGM AMPLIFIER INPUTS - NORMAL BGM OUTPUTS
AMP 1
100V
ZONE DC OUTPUTS
24 V
2 3 4 5 6
COM
1
100V
ZON6
COM
AMP 6
100V
ZON5
COM
AMP 5
100V
ZON4
COM
AMP 4
100V
ZON3
100V
AMP 3
COM
ZON2
COM
AMP 2
COM
ZON1
100V
AMP 1
COM
REMOTE SELECT
2 3 4 5 6 A
100V
PAGING AMPLIFIER INPUTS - ZONE OUTPUTS
1
100V
USE ONLY
RECOMMENDED
DC SUPPLY
24V 0.5A
COM
1.9 kg
+
100V
Weight
DC 24V
COM
482 x 44 x 130 mm
100V
Dimensions (WxHxD)
rear view
100V
24V DC ; 3A max / zone
Z6
SPEAKERS
100V
Zone LED
Aux output voltage
COM
Front panel switch, remote
Indicators
COM
Front panel switch
Zone selection - Paging
100V
6 BGM ; 6 Paging
Zone selection- BGM
COM
6
Amplifier inputs
Z1
COM
Number of zones
VOL CTRL
multiply ZS5602 for
more zones
100V
400W at 100V line
COM
0.5 dB max
Max load / channel
24V DC override
100V
100V
Insertion loss
ZS5602
COM
10W ; 0.42 A at ALL CALL
100V
24V DC ; 0.5 A
Power consumption
24V DC
100V
Operating voltage
zone control
100V
selectors
technical specifications
( 3 WIRE SYSTEM ONLY )
packing information
Carton Size : 555 (W) x 95 (H) x 295 (D) mm
: 2.5 kg
: 1 units / carton
SS6401 :
4 Input BGM Source Selector
Features
bgm source selector
SS6401 has 4 BGM source input via RCA jack with mono output suitable for
PA system. Its has line balancing circuitry which provide equal output level no
matter which input is selected, as different BGM source has different output
level. This avoids the trouble to adjust mixer volume whenever a different
source is changed.
4 input sources ; Cassette, CD, Tuner and Aux
Input level balancing circuit for constant output level for
different type of BGM source
technical specifications
Input voltage
24V DC ; 0.3 A
Consumption
0.15 A
Input level / Imp
CD
: 2V / 47 K Ohm
( max input )
Tuner
: 600 mV / 10 K Ohm
Cassette
: 500 mV / 10 K Ohm
Aux
: 1.25 V / 20 K Ohm
Input Connection
RCA mono
Output
RCA mono, 1V 600 Ohm
Gain ( max )
CD : -6 dB
/ Tuner : 4 dB
Cassette : 6 dB / Aux : -2 dB
Selection
Daisy chain
Dimensions ( W x H x D )
482 x 44 x 65 mm
Weight
1.6 kg
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
PAGING MIC
CD PLAYER
line out
TUNER
mic in
TO AMP
INPUT
CASSETTE
AUX
MIXER
SS6401
the emerging preference
Page 22
BC9730
power supply and distribution
24V DC Automatic Battery Charger
Features
BC9730 is a 24V DC current regulated battery charger with 3.3A
capacity, suitable for charging batteries of up to 100Ah. Charging
method is constant voltage with reducing current.
Constant DC voltage charging for 24V battery bank
3A initial charging current with reducing rate over charging time
Built in surge protection and resetable fuse
5 levels of protections are incorporated to prevent premature failure of
batteries, such as battery low voltage cut off, battery disconnect on
redundancy and reversed polarity protection circuitry.
Output short circuit protection
Thermal protection against overheating
Auto low battery disconnection with LED indication
Battery disconnect switch for disengaging battery from charger when
technical specifications
system not in used for a longer period
Battery reversed polarity protection
Input voltage
230 / 240V ac
Digital Volt and Ammeter
Charging voltage
27.3 ~ 27.8 V DC
Rear mains switch to avoid unnecessary switching off the unit
Charging current
3.3 A max with reducing current
No load consumption
30 mW
Max consumption
100 W
Protections
Resetable fuse
Built in surge suppression
Low battery auto disconnection
Thermal overheat protection
Short circuit protection
Indications
AC mains, charging and low batt.
Displays
Voltage and current
E/M back up rating
25 A max
Use ext. relay / contactor if reqd.
Terminals
Batt. inputs, EM load
Dimensions (WxHxD)
482 x 88 x 150 mm
Weight
4.1 kg
packing information
Carton Size : 555 (W) x 165 (H) x 295 (D) mm
Weight
: 4.9 kg
Qty
: 1 units / carton
PS9400 Regulated 24V DC Power Supply
PS9400 is a rack mounted 24V DC regulated power
pack designed uniquely for PA installations. It comes with
built in changeover relay which shall be connected to
back up 24V DC to allow continuous and uninterrupted
supply to the whole installation whenever the mains
failed.
application schematic
BC 9730
Features
LOAD PROTECTION
REV. POLARITY PROTECTION
PRESS TO RESET
PRESS TO RESET
+
24V DC 4A output switching power supply
MAINS : 220 - 240V
AC 50 / 60HZ
BACK UP
DC OUT
DC 30A
I
DC 5A
+
O
BC9730
BACK UP BATT.
O/P
Highly regulated output though mains fluctuates
WARNING !
OFF
ON
Built in surge and short circuit protection
Mains failure 24V DC output
to PS9400 or to load
BATTERY
BANK 24V
+
12V
Manual reset output circuit breaker protection
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
THIS UNIT MUST BE EARTHED
Back up battery overriding relay
+
E/M supply input
12V
24V DC output
TO EQUIPMENT USING 24V
DC (CONTINUOUS)
PS9400
technical specifications
Input ac voltage
220 ~ 240V ac
Output voltage
24V +/- 1%
Rating
4A nominal ; max 4.5A
No load consumption
50 mW
Efficiency
83%
Indicators
AC mains, battery input, DC output
Protections
Built in surge protection
Short circuit
CONTACTOR
Overload ( 105% ~ 150% )
TO EQUIPMENT / LOAD
WITH DC BACK UP
Note:
Using contactor is optional for loads exceeding 20A
packing information
Carton Size : 555 (W) x 95 (H) x 295 (D) mm
Weight
: 2.8 kg
Qty
: 1 units / carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
Over voltage ( 115% ~ 135% )
Output DC protection
Manual reset circuit breaker
Terminals
Batt input and load ; barrier connector
Dimensions (WxHxD)
482 x 44 x 150 mm
Weight
2.25 kg
the emerging preference
Page 23
SQ9715
power supply and distribution
When rules of switching On or Off the stack of AV or PA equipments
are neglected, it may cause damage to the component of the system,
such as speakers, amplifiers or video projectors.
Sequential Power Switcher
Features
7 channel with 6 A per channel ; total load 15 A maximum
SQ9715 offers a solution to the switching sequence by switching on in
sequence from channel 1 to 7 and vice versa during shutting down by
a push of a switch. Two units of SQ9715 can be linked to form 14
channels setup ; one being Master and the other as Slave.
Cascade two units to form 14 channel setup
Incremental switching from Ch. 1 to 7 ( or Ch. 1 to 14 in cascade mode )
Decremental switching from Ch. 7 to 1 ( or Ch. 14 to 1 in cascade mode )
Remote switching port via external noiseless contact
AC output via IEC connectors
Channel isolation via DIP switch
Ch. 7 with delay Off option for 2 min ; suitable for video projector powering
Lock mode to avoid incidental switching
Built in surge protection
technical specifications
Operating voltage
230 / 240V ac
Power consumption
50 mW ( without load )
Output voltage
230 / 240 V ac
Max load / channel
6A
Max total load
15 A
Output connection
IEC female socket
Max cascade
2 uts : total 14 channels
Surge protection
L-N, L-E, N-E.
Clamping voltage
870V ac
Turn on sequence
Step 1 to 7 incremental
Turn off sequence
Step 7 to 1 decremental
Step timing
2 seconds
Delay off option
Channel 7 via DIP switch
Delay off timer
2 minutes
Switch lock
Via front switch
Indicators
AC mains, Ch. on, Lock
Dimensions (WxHxD)
482 x 44 x 180 mm
Weight
2.7 kg excl. accessories
application schematic
ac output
ac
supply
CH.1 LOAD
:
:
:
:
CH.7 LOAD
SQ9715
MASTER
ac
supply
link cable
SQ9715
SLAVE
Units shown in cascade mode
with 14 channels in total.
Ch14 is last channel with delay
option
Control only at Master unit
CH.8 LOAD
:
:
:
CH.14 LOAD
rear view
packing information
Carton Size : 555 (W) x 165 (H) x 295 (D)
Weight
: 3.7 kg
Qty
: 1 units / carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 24
VC7000 / VC7000A / VC8000
VOLUME CONTROLLERS
They are suitable for 4 wire system installation with built in emergency overriding relay and
overriding LED indicator.
Features
Suitable for 4 wire system : 2 for 100V line , 2 for 24V DC overriding signal
2 plate mounting for better looks
Built in overriding relay to allow emergency signal to bypass volume attenuation
Overriding LED indicator whenever EM paging is activated
5 preset attenuation with OFF
Large cable terminal block for ease of termination
VC7000 SERIES (86 X 86 MM) :
VC7805 : 5W 8 OHM Resistive
VC7005 : 5W 100V Line Resistive
VC7010 : 10W 100V Line Auto Trans
VC7030 : 30W 100V Line Auto Trans
VC7050 : 50W 100V Line Auto Trans
VC7100 : 100W 100V Line Auto Trans
VC7150 : 150W 100V Line Auto Trans
VC7000A SERIES ( 70 X 120 MM ) :
VC7010A : 10W 100V Line Resistive
VC7030A : 30W 100V Line Auto Trans
VC7050A : 50W 100V Line Auto Trans
VC7100A : 1000W 100V Line Auto Trans
VC8000 SERIES ( 86 X 86 MM ) :
NOTE :
Wall concealed installation shall require back enclosure with depth of min 50 mm from
finishing surface for models with auto transformer. Normal electrical back enclosure
shall suffice for installation using resistive volume controllers. ie. VC7005 / 7010/8010
VC7000 series
VC8000 series
VARIANTS
VC8010 : 10W 100V Line Resistive
VC8030 : 30W 100V Line Auto Trans
VC8050 : 50W 100V Line Auto Trans
VC8100 : 100W 100V Line Auto Trans
VC7000A series
VOLUME CONTROLLER / PATCH
From contemporary to classic design, Amperes offers choices for the installation needs.
The variants are in three different designs and available in various ratings, ranging from 5
watts to 150 watts 100V line.
For 70 x 120 faceplate series :
Vertical and Horizontal version
available
application schematic
24V DC
OVERRIDE
VP7000 (OPTIONAL)
24V O/R
FR.
AMPLIFIER
localised area
100V
VC8000
100V
VC8000
100V
technical specifications
Power rating
Refer to variants
Overriding voltage
24V DC
Overriding current
15 mA per channel
Attenuation
6 steps incl. OFF
Attenuation / step
6 dB / step
Attenuation method
VC7005 / 7010 / 8010 - Resistive
Others - Auto transformer
SPEAKERS
SPEAKERS
Colour
White
Size ( W x H x D)
VC7000 / 8000 - 86 x 86 x 40 mm
VC7000A - 70 x 120 x 40 mm
Weight ( kg )
VC7805 / 7005 / 7010 - 100 gms
VC7010 / 7030 - 200 gms
loop to next speaker
loop to next speaker
VC7100 / 7150 - 330 gms
4 wire system installation
VC8010
- 200 gms
VC8030
- 220 gms
VC8050
- 235 gms
VC8100
- 345 gms
Optional item :
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
Conceal enclosure
77 x 77 x 60 mm
Surface enclosure
85 x 85 x 60 mm
the emerging preference
Page 25
VR7600 SERIES
rack mounted zone volume controllers
VARIANTS
VR7605 - 6 Zone X 50W 100V Line
VR7610 - 6 Zone X 100W 100V Line
VR7615 - 6 Zone X 150W 100V Line
application schematic
PA 2120
POWER
AMPLIFIERS
120 Watts
POWER
POWER
PA 2120
I
PROTECT
O
SIGNAL -10 dB
CLIP
SIGNAL -40 dB
volume controller / patch
VR series is available in three variants with 6 zones at each panel. It shall
be mounted at rack to enable volume of each zone to be controlled or set
at the control room.
Features
ZONE SELECTOR
6 zones with 50 / 100/ 150 W 100V line rating for each zone
ZS 5121
OVERRIDE
24V DC for
emergency
override
1
2
3
4
5
6
7
SPEAKER ZONE SELECT
8
9
10
11
12
ALL
CALL
Customised zone rating option available
VR7000 SERIES
Suitable for 4 wire system : 2 :100V audio & 2 :24V DC overriding
Built in overriding relay for emergency volume bypass
LINE SURV.
MENU
ENTER
PRE
NEXT
technical specifications
STATUS
CH1
CH2
CH3
CH4
CH5
CH6
BUZZER
AUTO
VR7605 / VR7610 / VR7615
NORMAL
FAULT
24V
100V
100V
VOLUME
CONTROLS
SPEAKERS
Power rating
50 / 100 / 150W 100V line / zone
Overriding voltage
24V DC
Overriding current
15 mA per channel
Attenuation
6 steps incl. OFF
Attenuation / step
6 dB / step
Attenuation method
Auto transformer
Size ( W x H x D)
482 x 88 x 60 mm
Weight ( kg )
3.4 / 4.5 / 4.8 kg
VR should be installed before LS4600 to avoid false fault detection
due to variation of impedance whenever volume is adjusted.
AV7200 :
auto volume controller
100W 100V Line Auto Volume Controller
preliminary information
A V 7 20 0
A U T O M A T IC V O L U M E C O N T R O LLE R
There is always a need to regulate the speaker volume in areas
which has significant variance of ambience noise level between
different time in a day, such as in public area ie. bus station,
airports, etc.
M IC
HI
AV7200 controls the speaker volume automatically by reducing or
increasing the 100V line output from amplifier to the localised area,
which the unit shall be located. Unlike most AVC, AV7200 controls
the 100V speaker line instead of audio signal prior to amplifier input.
LO
S E N S IT IV IT Y
1
2
3
4
5
6
O U T P U T LE V E L
O V E R R ID E
This would enable the unit to be applied to existing system without
having to run additional microphone cable to the main rack. It can
be installed next to the existing volume controller at the particular
area and powered by a 24V power adaptor. A significant cost saving
shall be achieved with this method.
application schematic
Features
Power Amplifier
PA 2120
120 Watts
Installation at localised area ( at existing volume controller ) without
POWER
POWER
PA 2120
I
PROTECT
O
SIGNAL -10 dB
amperes
CLIP
SIGNAL -40 dB
additional cable re-run ( easily retrofit to existing system )
24V DC for
overriding
100V speaker line control with 6 step attenuation
LS4600
( optional )
MENU
ENTER
PRE
NEXT
Adjustable noise sensing sensitivity
STATUS
CH1
CH2
CH3
CH4
CH5
CH6
BUZZER
Built in overriding relay for emergency volume bypass
AUTO
NORMAL
amperes
FAULT
100V Line
24V O/Ride
technical specifications
AV7200
AV7200
A U T O M A T IC V O L U M E C O N T R O LLE R
24V DC PSU
via adaptor
A U T O M A T IC V O L U M E C O N T R O LLE R
M IC
HI
M IC
LO
HI
2
3
4
5
O U T P U T LE V E L
S E N S IT IV IT Y
6
1
O V E R R ID E
2
3
4
5
O U T P U T LE V E L
6
O V E R R ID E
AV7200
AV7200
Zone Speakers
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
Power rating
100W 100V line
Operating voltage
24V DC : 40 mA
Attenuation
6 steps ; -6 dB per step
Emergency overriding
24V DC ; 0.15 A
Sensitivity adjustment
2 level
Size ( front panel )
172 x 86 mm
Weight ( excl. enclosure )
500 gms ( est )
LO
S E N S IT IV IT Y
1
Zone Speakers
the emerging preference
Page 26
VP7501 :
VP7810 :
Local Speaker Patch Panel
100V - 8 Ohm Speaker Patch Panel
localised speaker patch panel
VP7501 shall be used to isolate a group of speakers (meeting room, etc)
from central PA system to allow a separate PA amplifier to utilise those
local speakers, but shall be overrided by main system in the event a 24V
overriding signal is present.
Features
VP7501
Suitable for 4 wire system : 2 x audio, 2 x 24V DC overriding
Built in overriding relay for emergency bypass with LED indicator
application schematic
Also available with 70 x 120 mm front panel
24V DC
Override
from main
PA system
VOL.CONTROL
patch using
1/4" mono
jack
LOCAL SPEAKER PATCH IN
100V
SPEAKER VOLUME
2
3
4
1
OFF
100V
5
OVERRIDE
OVERRIDE
VOLUME CONTROLLER / PATCH
VP7810 works similarly but the local speaker is 8 Ohm, ie. setup in hotel
room speaker connected to TV audio output via a mini amplifier. In the
event of emergency, it shall allow the incoming 100V line to take over and
to match the speaker’s impedance.
VP7501
SPEAKER
C/W
TRANS
100V
audio inputs
VP7810
MIXER AMP (LOCALISED)
VP7501 application schematic
technical specifications
VP7501 / VP7810
Power rating
50W 100V line / 10W 8 Ohm
Overriding voltage
24V DC : 15 mA
Patch connection
VP7501 : 1/4" phone jack - front patch
audio in
from TV
etc
8 OHM OUT
MINI AMP
VP7810
VC7805
PA - TV BGM
EM OVERRIDE MODULE
SPEAKER VOLUME
2
1
OFF
3
4
5
OVERRIDE
OVERRIDE
VP7810 : hardwired
Cablings
4 wire system ( 2 audio ; 2 overriding )
Size ( front panel )
86 x 86 mm
70 x 120 mm available upon request
Weight ( excl. enclosure )
70 / 180 gms
Optional enclosure :
100V output from
central PA system
4 / 8 OHM
SPEAKER
24V DC Override
VP7810 application schematic
Concealed ( WxHxD )
77 x 77 x 60 mm
Surface ( WxHxD )
85 x 85 x 60 mm
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 27
ceiling speakers
Dual Cone Speaker ABS Enclosure
Dual Cone Speaker Metal Enclosure
Co-Axial Speaker ABS Enclosure
CS510 :
CS610 :
CS606 :
CS620 :
CS840 :
6” 6W 100V Line
6” 20W 100V Line
8” 40W 100V Line
speakers
5” 6W 100V Line
6” 6W 100V Line
Available in 5” and 6” of driver size complete
with matching transformer of three tappings ;
1, 3 or 6W. Back enclosure are supplied as
integral part of the speakers made from
quality ABS plastic. Installation is made easy
with its screw mounting mechanism
CS620 and 840 meets the requirement of hi fidelity
of sound reproduction in areas such as function
halls, restaurants and also for sound reinforcement
at hall balconies. They are available in 6” and 8”
version of speaker driver with tweeter and 100V
line matching transformer.
Available in 6” dual cone speaker with back
metal enclosure, grill and baffle and multi tap
matching transformer of 1, 3 and 6W 100V
line. This model shall be suitable for
installations that demand fire resistant
version of dome.
technical specifications
CS510
CS610
CS606
CS620
CS840
SPEAKER
6W 100V line nominal ( max 10W )
Power rating
5” (125mm )
Diameter
6” (150mm )
6W 100V line nominal
20W 100V
40W 100V
6” (150mm )
6.5” ( 160mm )
8” ( 200mm )
Cone type
Dual cone
Dual cone
Impedance
8 Ohm
8 Ohm
Freq response ( +/- 5dB )
SPL @ 1W / m ( +/- 3dB )1KHz
150 ~ 19 KHz
120 ~ 19 KHz
Co-axial
8 Ohm
150 ~ 16 KHz
80 ~ 18 KHz
90 ~ 19 KHz
93 dB
92 dB
91 dB
88 dB
90 dB
3 oz
5.3 oz
2 oz
10 oz
15 oz
40W 100V line
Magnet weight
TRANSFORMER
Tapping ( 100V line )
1 / 3 / 6 W 100V line input
1 .5 / 3 / 6 W 100V line input
20W 100V line
Primary impedance
10K / 3.3K / 1.6K Ohm
6.7 K / 3.3K / 1.6K Ohm
500 Ohm
8 Ohm
8 Ohm
Secondary impedance
250 Ohm
8 Ohm
MECHANICAL
White metal / ABS white
Grille / enclosure
Overall size ( dia x height ) mm
White metal / ABS white
175
165
177 x 130
230 x 102
200 x 100
240 x 145
950 g
2.4 kg
715 g
Weight
White metal
140
Cutting hole dim ( mm )
785 g
Off white
Colour
205
240
280 x 145
2.9 kg
Off white
Beige white
packing information
CS510 : 885 (W) x 363 (H) x 300 (D) mm
17.5 kg
20 uts per carton
CS610 : 683 (W) x 473 (H) x 360 (D) mm
21.6 kg
18 uts per carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
CS606 : 540 (W) x 215 (H) x 420 (D) mm
12.5 kg
10 uts per carton
CS840 : 305 (W) x 305 (D) x 175 (H) mm
2.6 kg
1 ut per carton
CS620 : 265 (W) x 265 (D) x 170 (D) mm
3.1 kg
1 ut per carton
the emerging preference
Page 28
surface mount & column
Surface Mount Speaker
Surface Mount Speaker
Column Speaker
BS410 :
DV410 :
CH720 : 20W 100V Line
CH730 : 30W 100V Line
CH730 : 40W 100V Line
4” 6W 100V Line
speakers
4” 10W 100V Line
It is constructed with high quality ABS plastic
with 4” dual cone speaker driver and multi
tapping matching transformer of 1 / 3 / 6 and
10W 100 V line. Suitable for wall and ceiling
installation with optional tilt mounting bracket.
Available in white colour.
A classic yet favourite model which is suitable
for installations in small enclosed areas such
as staircase, office, etc. Available in white
colour with multi tap matching transformer of
1 / 3/ and 6 W 100V line, fit for vertical or
horizontal installations.
Built ruggedly with aluminum die cast housing and
available in 3 power rating of 20 / 30 and 40W 100V
line with half or full power tapping. Suitable for
classrooms, hyper markets, mosques, etc.
technical specifications
BS410
DV410
CH720
CH730
CH740
20W 100V
30W 100V
40W 100V
2 x 4”
3 x 4”
4 x 4”
SPEAKER
10W 100V
Power rating
6W 100V
Diameter
4”
Cone type
Dual cone
Dual cone
8 Ohm
Impedance
8 Ohm
100 ~ 16 KHz
100 ~ 18 KHz
85 ~ 15 KHz
SPL @ 1W / m ( +/- 3dB )1KHz
92 dB
90 dB
91 dB
Magnet weight
7.5 oz
3.0 oz
Freq response ( +/- 5dB )
80 ~ 15 KHz
93 dB
75 ~ 15 KHz
95 dB
7.5 oz
TRANSFORMER
1 / 3 / 6 / 10W
Tapping ( 100V line )
Primary impedance ( Ohm )
1 / 3 / 6W
10K / 3.3K / 1.6K / 1K
10K / 3.3K / 1.6K
10 / 20W
15 / 30W
20 / 40W
1K / 500 Ohm
660 / 330 Ohm
500 / 230 Ohm
8 Ohm
Secondary impedance
8 Ohm
MECHANICAL
ABS with metal grille
Grille / enclosure
Overall size ( W x L x H ) mm
Aluminum / metal grille
185 x 215 x 90
220 x 190 x 100
400 x 100 x 145
495 x 100 x 145
605 x 100 x 145
1.1 kg
750 g
3.2 kg
3.7 kg
4.6 kg
Weight
White
Colour
Dark grey / front black grille
BS410
Carton
Weight
Qty
550 (W) X 215 (H) X 420 (D) mm
14.5 kg
12 ut per carton
CH720
Carton
Weight
Qty
510 (W) X 363 (H) X 300 (D) mm
7.8 kg
2 ut per carton
DV410
Carton
Weight
Qty
590 (W) X 400 (H) X 303 (D) mm
15.4 kg
18 ut per carton
CH730
Carton
Weight
Qty
683 (W) X 473 (H) X 306 (D) mm
9.0 kg
2 ut per carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
CH740
Carton
Weight
Qty
the emerging preference
802 (W) X 563 (H) X 389 (D) mm
11.0 kg
2 ut per carton
Page 29
music & array speakers
Foreground Music Speaker
Foreground Music Speaker
Cabinet Array Speaker
FS415 :
FS630 :
FS520 :
FS625 :
LA4100 :
5” 15W 100V Line
6” 25W 100V Line
4” 120W 100V Line
speakers
4” 10W 100V Line
6” 30W 100V Line
White and black colour available
Only black colour available
Only black colour available
Available in 4” and 6” of driver size complete
with matching transformer and mounting
bracket. They are suitable for foreground soft
music such as restaurants, shops and general
sound reinforcement in meeting room,
corridors, etc.
These models deliver wider frequency range
from bass to treble for satisfying a more
demanding audience. Among applications
includes bars, restaurants, function halls and
could easily complement any sound
reinforcement systems.
LS4100 is array speaker built with 4” driver
delivering a punch of 120W of output with
dispersion angle of H120 x V60 degree and high
SPL. Most suitable for application like mosques,
halls, public areas such as bus stations, airports,
etc where speech clarity is utmost important.
technical specifications
FS630
LA4100
10 W
30 W
120 W 100V
15 W
25 W
4” (100mm )
6” (150mm )
4“
5” (125mm )
6” (150mm )
FS415
FS520
FS625
SPEAKER
Power rating
Diameter
Speaker type
2 way speaker
Single cone
8 Ohm
8 Ohm
Impedance
Freq response ( +/- 5dB )
95 ~ 16 KHz
85 ~ 19 KHz
85 dB
SPL @ 1W / m ( +/- 3dB )1KHz
88 dB
2 way speaker
8 Ohm
130 ~ 18 KHz
85 ~ 16 KHz
96 dB
87 dB
80 ~ 15 KHz
89 dB
TRANSFORMER
Tapping ( 100V line )
10 W
30 W
60 / 120 W
15 W
25 W
Primary impedance
1 K Ohm
330 Ohm
167 / 83 Ohm
667 Ohm
400 Ohm
8 Ohm
Secondary impedance
8 Ohm
8 Ohm
MECHANICAL
ABS enclosure
Grille / enclosure
Overall size ( WxHxD ) mm
Polypropelyne (PP)
ABS enclosure
160 x 220 x 140
215 x 295 x 190
205 x 585 x 195
169 x 266 x 160
212 x 328 x 190
1.1 kg
2.8 kg
21 kg
2.1 kg
3.0 kg
Weight
White and Black available
Colour
Black
White and Black available
packing information
FS415 : 415 (W) x 380 (H) x 540 (D) mm
9.8 kg
8 uts per carton
FS630 : 640 (W) x 415 (H) x 495 (D) mm
25.5 kg
8 uts per carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
LA4100 : 485 (W) x 665 (H) x 275 (D) mm
21 kg
2 uts per carton
FS520 : 415 (W) x 380 (H) x 540 (D) mm
18.7 kg
8 ut per carton
FS625 : 640 (W) x 415 (H) x 495 (D) mm
26 kg
8 ut per carton
the emerging preference
Page 30
horn & projection speakers
Horn Speakers with Round Flare
Horn Speaker with Rect. Flare
Sound Projector
HS815 :
HS830 :
HS820 :
HS822 :
SP100 :
6” x 8” 15W 100V Line
8” x 11” 20W 100V Line
10W 100V Line
speakers
8” 15W 100V Line
12” 30W 100V Line
Both models are constructed using rounded
aluminum flare of 8” ( HS815 ) and 12” (
HS830 ) with multiple power selection via
rotary switch. Suitable for schools, mosques,
car parks, factories at indoor or under
shade installations and that requires omni
direction sound broadcast.
Constructed with high impact ABS flares of
different size to suit installation sites where
pattern of broadcast shall be controlled, such
as low level carparks, corridors, etc. Suitable
for indoor or outdoor sites with IP64 rating.
SP100 is used when a more directional sound
projection is required for areas such as at narrow
corridors, tunnels, walkways, etc. It has aluminum
body with metal grille and available with standard
power rating of 10W 100V line. Mounting position
can be either at wall or hanged from ceiling.
technical specifications
Power rating
HS815
HS830
SP100
HS820
HS822
15W 100V
30W 100V
10W 100V
15W 100V
20W 100V
Power tapping ( W )
1 / 3 / 5 / 10 / 15
Fixed
3 / 7.5 / 10 / 15 W
3 / 7.5 / 10 / 20 W
Impedance ( Ohm )
670
330
1 K Ohm
3.3 K
3.3 K
1K
670
-
1.3 K
1.3 K
2K
1K
-
1K
1K
3.3 K
2K
-
670 Ohm
500 Ohm
300 ~ 8 KHz
Frequency response ( +/-5 dB )
SPL ( 1 W/m @ 1KHz )
3 / 5 / 10 / 15 / 30
10 K
3.3 K
-
350 ~ 7 KHz
300 ~ 10 KHz
180 ~ 15 KHz
250 ~ 8 KHz
105 dB
88 dB
105 dB
103 dB
Aluminum
Flare material
Flare dimension
Overall size ( Dia x L ) mm
Weight
8” round
12” round
-
210 x 240
310 x 325
140 x 195
L : 240 mm
1.55 kg
1.85 kg
2 kg
1.5 kg
Beige
Colour
107 dB
ABS
Aluminum body
160 x 220 mm
205 x 280 mm
L : 280 mm
1.9 kg
White
White
packing information
HS815 : 695 (W) x 480 (H) x 520 (D) mm
23 kg
12 uts per carton
HS820 : 510 (W) x 250 (H) x 250 (D) mm
10.7 kg
6 uts per carton
HS830 : 665 (W) x 665 (H) x 355 (D) mm
10.6 kg
4 uts per carton
HS822 : 590 (W) x 300 (H) x 430 (D) mm
10.0 kg
4 uts per carton
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
SP100 : 75 (W) x 75 (D) x 255 (H) mm
2.1 kg 1 uts per box
the emerging preference
Page 31
enclosures
EC7012 :
ES7012 :
EC9090 :
ES9090 :
70 x 120 mm Back enclosure for concealed mounting
70 x 120 mm Back enclosure for surface mounting
86 x 86 mm Back enclosure for concealed mounting
86 x 86 mm Back enclosure for surface mounting
All models with 60 mm depth, suitable for volume controllers with
auto transformers. Enclosures are optional items and to be ordered
separately from volume controllers / patch panels.
patch panels
MR5000 :
MR1000 :
MP1000 :
MP2000 :
5 Way rack mounted female XLR patch panel
10 Way rack mounted female XLR patch panel
Single inlet wall mounted female XLR patch panel
Double inlet wall mounted female XLR patch panel
accessories / complementary products
Quality XLR connectors are used in the above series. Other brands of
inlets are available upon request.
rack panels
BP1000 :
BP2000 :
VP1000 :
VP2000 :
1 hu blank panel
2 hu blank panel
1 hu ventilation panel
2 hu ventillation panel
Available with standard Amperes mounting ears for harmonious look
with other amperes equipments.
Panels are available in black powder epoxy coating.
power supply
PS1205 :
PS2405 :
PS9000 :
12V 0.5A ac / dc regulated power adaptor
24V 0.5A ac / dc regulated power adaptor
24V 4.5A dc switching power supply
Regulated power adaptor for powering single unit of equipment.
Equipments are not supplied with power adaptor and are to be
ordered separately.
For larger system, we recommend that proper DC supply to be used
with relay changeover for DC back up supply. ie. Amperes PS9400.
sla batteries
122600
124000
126500
121000
:
:
:
:
12V 26 Ah Maintenance free SLA battery
12V 40 Ah Maintenance free SLA battery
12V 65 Ah Maintenance free SLA battery
12V 100 Ah Maintenance free SLA battery
SLA batteries are sold in blocks of 24V ( 2 x 12V block ). Above are
common ratings widely used. Other ratings are available upon
request.
We recommend that Constant Voltage with auto current reducing
charger to be used, ie. Amperes BC9730.
www.ampereselectronics.com
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
Page 32