Download Mitsubishi Heavy Industries SRK20ZG-S Specifications
Transcript
High Performance Air Conditioning SR series Residen t i a l A i r C o n d i t i o n e r s Wall Mounted type SRK COP 5.71 ( in theSRK20ZIX-S cooling operation ) 3D AUTO Programmed air distribution Sophisticated design Quiet operation Industry leading energy efficiency and reliability from our advanced technology. Floor Standing type ZIX series SRF COP 4.80 ( in theSRF25ZIX-S cooling operation ) Auto air outlet selection lower and upper outlets Sophisticated design Quiet operation High Efficiency The industry’s highest EER COP levels The ZIX, ZG and ZE series clear the 2010 MEPS. EER in Cooling COP in Heating 5.71 5.20 5.5 5.0 4.5 4.14 4.0 5.5 3.33 5.26 5.0 3.42 3.23 3.33 4.48 4.5 2.93 3.85 3.5 5.56 4.44 4.07 4.0 3.82 3.62 2.93 3.5 3.21 3.0 3.0 2.5 2.5 SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1 SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1 DC PAM inverter An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides higher performance. Time DC PAM INVERTER DC PowerActiveModule PAM INVERTER Room Temp. PAM PWM Set Temp. Even Temperature DC PAM INVERTER Rated Capacity ON Compressor (rps) Utmost comfort and energy efficiency achieved with large output power and control optimisation DC compressor motor Time CONVENTIONAL INVERTER Motor Efficiency(%) Magnet Motor Room Temp. Improving Set Temp. Improving CONVENTIONAL Induction Motor Low Revolution speed High ON Rated Capacity OFF Compressor (rps) Less advanced technology does not address the ON/OFF cycle issue. New Inverter Control (Vector control) New Inverter Control has applied the new advanced technology of Vector control enabling:• Smooth operation from low to high speed • Smooth Sine Voltage Wave form is achieved • Energy efficiency has improved in low speed range 3 OFF High Efficiency Our Latest Technologies New propeller fan Silicon-coated PCB The new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption. In synergy with the leaf shape grill has seen an improvement of energy efficiency by 5% and a decrease of sound level.(SRC50/60ZIX-S) The printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions. Energy saving leaf shape grill The leaf shape grill was developed in order to maximize natural air flow sent by the propeller fan along the grill. The airflow is very smooth with minimum air resistance. This has lead to a decreased fan motor load and improvement of energy efficiency. High efficiency scroll compressor. Low vibration and low sound revel By using a scroll compressor there has been an improvement of energy efficiency. Lower vibration and lower sound level have been achieved. Further improvement to efficiency was realized by use of a neodymium magnet applied in the compressor motor. (SRC50/60ZIX-S) ZAM steel sheet ZAM steel sheet is used on the base of the outdoor units. ZAM has superior corrosion resistance and scratch resistance properties compared to conventional materials. 1) ZAM is a registered trademark of Nissin Steel Co., Ltd. 2) ZAM is a coined name applied to hotdipped zinc-aluminum-magnesium-alloycoated steel sheet developed by Nissin Steel Co., Ltd. 4 photo is composite image Indoor unit Outdoor unit A combination of fin configuration and copper tube has enabled maximum air flow whille keeping the same size width of the indoor unit. Efficiency rate of heat exchanger has been drastically improved by 30% compared with previous models. The new fin design allows maximum air flow and saving energy simultaneously. Redesigned by changing the fin configuration from flat sheet to new M shape fin, efficiency has been improved by 10%. An optimum balance of heat transfer and air flow has been achieved. Airflow 3D AUTO Vertical + Horizontal AIR SCROLL 3 motors make 3 independent controls Programmed air distribution Applied models 3D AUTO 3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air flow controls. The airflow is uniform, quiet and reaches at long distance from the indoor unit. Programmed 3D AUTO Hi-Power (Quick) Cool Shower 1 SRK-ZIX, SRK-ZG, SKM-ZG SRK63/71ZE, Manual Setting only Manual Setting Floor Heating Vertical Swing Swing Wide Swing (Every Corner) Swing 2 Horizontal Air Scroll 8 Direction Swing Center (Long) 3 Swing 3 4 8 7 6 5 Cool Shower Floor Automatic control of air flow volume and air flow direction enables comfortable air conditioning of the entire room. In cooling operation, cooled air flows directly to the ceiling not directly onto the occupants of the room. The comfort cooled air flow comes down from the ceiling like a soft shower. In heating operation, warm air flows to the floor directly and spreads along the floor. The concentration of the warm air at floor level increases comfort. 5 2 Swing Wide-Air (Equal) 4 1 Swing Spot Wide Individual control of right and left louver enables air flow direction from the right and the left side of the unit, setting the most preferable air flow direction and determining whether direct air flow is required or not. At the same time, this minimises energy loss. High Efficiency Applied models All SRK, SKM Aircraft technology was used in the design of the air conditioner’s airflow system Jet Air Scroll Long Reach & Silent Air Flow We used the same aerodynamic analysis technology as used in developing jet engines. CFD (computational fluid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The airflow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The airflow is uniform, quiet and reaches a long distance from the indoor unit. Fast Slow Colors in the figure show the air speed. Applied models SRK50/60ZIX, SRK63/71/80ZE Long Reach Air Flow The jet technology enables powerful airflow ideal for large living areas and commercial premises, increasing your comfort. SRK50/60ZIX 15m Applied models SRK-ZIX, SRK-ZG, SKM-ZG Applied models SRK-ZIX SRK63/71/80ZE (in cooling operation) (in cooling operation) 17m Positioning of Installation You can set the left-right air flow directions when you install the air conditioner near the side wall by remote controller operation. New louver The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air flow volume, it has improved controllability of the right to left swing function. 80% increased previous New 6 powerful Clean Air Generates the same amount of negative ions as a forest environment Applied models All SRK, SKM 24-hour ION The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost. Keeping the indoor unit clean Applied models All SRK, SKM Self Clean operation The ‘self clean operation’ is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control. Stop run Normal operation Situation of mold after one week 2hrs Clean operation When you don’t execute “Self Clean Operation” Fungal mycelia expand. Fungal mycelia When you execute “Self Clean Operation” The spore of mold doesn't germinate. Spore of mold Shuts off automatically The air in your room is kept fresh Allergen Clear system Push ALLERGEN Mode Catching Allergen on the Filter 7 Spore of mold First in the world The ‘Allergen Clear system’ suppresses the influence of the allergen caught by the filter by controlling the temperature and humidity. 20 of Patent Pending Cooling Operation To make condensing water. Heating Operation To give moisture to the Filter to inactivate allergen AIR Purify Self-Clean Operation To dry up the indoor unit Applied models SRK-ZIX, SRK-ZG, SRK-ZE Clean Air This is the original and only technology to control the temperature and humidity for inactivating allergens Allergen Clear Filter Sterilization Mechanism Enzyme + Urea deactivates allergens and kills bacteria Urea H2N- Enzyme Slack of high order structure Reduction in a molecule -COOH Protein structure of allergen A molecule is decomposed Rate of inactivation against allergens collected on the filter 93.6% 100 The allergen clear filter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens but some bacteria, moulds and viruses. Even if allergen, mould, virus or bacteria fly off the filter they are deactivated so the air in your room is kept fresh. Inactivation rate(%) Virus i Virus p 50 0 House dust mite A species of mite *1 *1 Cedar pollen *2 Epithelium of cat *2 *3 *3 First in the world Natural Enzyme Filter Conventional Filter Analysis Zone The enzymes used in these filters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the filter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it. 99.0% 72.7% Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds (Cat hair, dust mite, pollen etc.) Enzyme filter 99.9% 83.5% 83.5% Enzyme Filter Airflow *1 Test method: ELISA colorimetric method / ELISA fluorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536 *2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536 *3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145 Analysis Zone Enzyme's sterilizing mechanism Bacterium Enzyme Enzyme Coupling Powerful sterilizing effect Cell wall Filter fiber The deodorizing ability of this filter can be easily restored simply by cleaning and exposing to the sunlight Photocatalytic Washable Deodorizing Filter This filter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This filter maintains its deodorizing effect even after many repeat uses. Used in models 8 Indoor Unit SRK-ZIX SRK-ZE SRK-ZG SRF-ZIX Allergen Clear Filter 1pc 1pc 1pc - - Natural Enzyme Filter - - - 1pc 1pc Photocatalytic Washable Deodorizing Filter 1pc 1pc 1pc 1pc 1pc Filter SKM-ZG Advanced Technology Anti-microbial specifications and design will deliver cleanliness and safety Applied models Anti-microbial indoor fan All SRK, SKM Anti-microbial treatment Anti-microbial indoor fan The indoor fan has undergone anti-microbial treatment Comparison of growth of bacteria and mold on fan surfaces to resist growth of mould and germs. Mould creating (microscopic image) odours which can occur when an air conditioner are not in operation are prevented. ·Intestinal bacteria (Escherichia coli IFO 3972) ·Staphylococcus aureus subsp. aureus IFO 12732 Testing Authority: Japan Food Analysis Center Test Results Issued: 2004-4-7. Test Report No.: 104034022-001 Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801 2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects: Test Methods for Plastic Products, etc. ·Apergillus niger IFO 6341 Testing Authority: Japan Food Analysis Center Test Results Issued: 2004-4-23. Test Report No.: 104034022-002 Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801 2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects: Test Methods for Plastic Products, etc. without with Anti-microbial Anti-microbial without with Anti-microbial Anti-microbial Aspergillus niger IFO 6341 Escherichia coli IFO 3972 In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab, 24 hrs after contact with bacteria, cultured on agar media. Live Bacteria Count on Measured Test Pieces Tested Contaminant Escherichia coli IFO 3972 coli Staphylococcus aureus Aspergillus niger Test Pieces Immediately after contact Not treated Measurement 1 1.9 x 105 After 24 hrs at 35°C Test piece 1 Not treated <10 3.8 x 106 <10 4.9 x 106 <10 7.2 x 106 Immediately after contact Not treated 1.4 x 105 1.6 x 105 1.3 x 105 After 24 hrs at 35°C Test piece 1 Not treated <10 8.6 x 105 <10 4.5 x 105 <10 3.6 x 105 Immediately after contact Not treated 1.5 x 104 2.2 x 104 1.6 x 104 After 24 hrs at 35°C Test piece 1 Not treated <10 1.0 x 104 <10 1.2 x 104 <10 2.5 x 104 Test Pieces 1) Products with Antimicrobial and Antifungal Treatment 9 Bacteria Count Per Test Piece Measurement 2 Measurement 3 5 x 1.6 10 1.3 x 105 Measurement Advanced Technology Applied models SRK-ZIX, SRK-ZE, SRK-ZG, SCM-ZG Wide Operation Range Heating and cooling operations are possible at an outdoor temperature as low as –15°C -15°C Our new advanced technology has improved the heating and cooling operation range. Units can be installed when heating or cooling operation -15°C is required at low ambient conditions down to -15°C. +46°C Cooling 40 30 20 10 0 -10 -20 +21°C Heating 50 For the capacities under low temperature conditions, refer to technical manual. High quality air long reach & silent flow Quiet operation This is the secret of quiet operation C Nor 60dB e Quiet offic 50dB 60dB 50dB 21dB a rary Late night in ea burban ar typical su In the lib 40dB 21dB 30dB SRK20ZIX-S 0dB SRK50/60ZIX, SRF-ZIX life ns ersatio mal conv 70dB The combination of the jet airflow system and serration 40dB stabilizer configuration ensures uniform breeze to every 30dB corner of the room. It also makes it possible to lower the dB 20 operation noise further by minimizing the interaction 10dB between airflow and the fan. Applied models r everyday ises in ou miliar no with fa omparison (In the Cooling Lo mode) Three sensors Control of room temperature and humidity is very important for people to live a comfortable life. Use of three sensors to control indoor temperature, indoor humidity and outdoor temperature enable the unit to obtain optimum air-conditioning. Sensor for indoor temperature Sensor for outdoor temperature Sensor for indoor humidity Applied models All SRK, SKM, SRF Applied models SRK50/60ZIX, SRK-ZE Washable filter and easy cleaning of air inlet panel Removing the air filter is quite easy. Keeping the air filter clean is an effective way to save energy and keep the original powerful performance of your unit. The air inlet panel is also removable and can be cleaned easily. Long piping length Piping length has been extended and design flexibility has been improved. Maximum pipe length 30m Maximum height difference 20m 10 Product line up R410A Model SRK-ZIX series SRF-ZIX series Floor Standing type 2.5 20ZIX-S 25ZIX-S 35ZIX-S 50ZIX-S 25ZIX-S 35ZIX-S 50ZIX-S 2.8 6.0 6.3 7.1 8.0 63ZE-S1 71ZE-S1 80ZS1-X NEW 60ZIX-S NEW HEAT PUMP DC INVERTER Capacity Range (kW : Rated cooling capacity) 3.5 4.0 5.0 5.6 2.0 SRK-ZE series SRK-ZG series 20ZG-S Model SKM 25ZG-S 35ZG-S 2.0 2.2 2.5 2.8 3.5 20ZG-S 22ZG-S 25ZG-S 28ZG-S 35ZG-S 4.0 4.5 4.8 5.0 5.6 6.0 6.3 7.1 8.0 50ZG-S Wall mounted type 60ZG-S 71ZG-S SRRM Ceiling Concealed type INVERTER Free-Multi 25ZF-S 35ZF-S 50ZF-S 60ZF-S 25ZF-S 35ZF-S 50ZF-S 60ZF-S STM 4way ceiling cassette type 600 x 600 Super Compact type 2 rooms OUTDOOR UNIT SCM 40ZG-S 45ZG-S 3 rooms 3 rooms 48ZG-S 60ZG-S 4 rooms 80ZG-S 11 Functions Filter Allergen Filter SUN Filter Allergen Clear Filter The filter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them. Enzyme Filter Photocatalytic Washable Deodorizing Filter Natural Enzyme Filter Enzymes used in the filter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the filter and destroy them. It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing to the sunlight. Comfortable Functions Fuzzy Auto Mode "HI POWER" Operation Automatically the unit determines its operating mode and temperature and setting based on a fuzzy calculation and adjusts the inverter frequency. The unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly. Sta The air conditioner automatically selects from heating, cooling or dry operation. r t Sp t ur Automatic Operation 3HOT K eep Three "Hot" System ‘Hot start’ enables the unit to begin operation immediately. ‘Hot spurt’ a fast heating system that works to increase the temperature setting by two degrees. ‘Hot keep’ used during the automatic defrost cycle to prevent cool air being circulated. These three operational control systems help ensure comfortable and efficient heating. Comfortable Air Flow Functions 3D Auto Auto You can choose the best heating or cooling pattern with the touch of a button. Auto Flap Auto Flap Mode COOLING & DRY Horizontal blowing The unit automatically selects the optimal angle whatever the operation mode. Air Scroll Air Scroll The swing of the flap causes the air flow to spiral and the breeze reach all corners of the room. HEATING Slant forward blowing COOLING & DRY Thick line : moves quickly Thin line : moves slowly HEATING Thick line Thin line Memory Memory Flap While the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts operation. UP/DOWN Up/Down Flap Swing SWING FLAP The Up/Down flap can be adjusted to Flap moves up and down continuously. the preferred angle anywhere between horizontal and perpendicular. Lateral Swing Lateral swing The louver swings from right to left automatically. Louver angle can be fixed in any desired position. Air outlet Air outlet selection selection Both lower and upper air outlets and upper air outlet can be selected. Positioning of Installation : moves quickly : moves slowly Positioning You can set the left-right air flow directions when you of installation installed the air conditioner near the side wall by remote controller operation. Convenience & Economy Functions 24-hour On/Off Programmable Timer On Timer On Timer This enables the operation to start a little earlier so that the room is near to set temperature at ON time. Economy Economy Mode The unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation. Dry Operation DRY The unit dehumidifies the room by intermittent cooling operation. 24h Timer By combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly. OFF Timer Off Timer The unit stops at the specified time. Sleep Sleep Mode The room temperature is automatically controlled during that set sleep mode period ensuring that the room temperature will not get too hot or cold. Maintenance & Prevention Functions MC Microcomputer-Operated Defrosting This function automatically eliminates frost and helps minimize excessive operation in other modes. Detachable Detachable Indoor Air Inlet Panel The air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed. Self-Diagnostic Function Self Diagnostic If the air conditioner malfunctions an internal microcomputer When removing the air inlet panel for internal cleaning or other reason, open the grill by 65 degrees and then pull it to the side. runs a self diagnosis. Inspection and repair should be performed by authorized dealers. Others Back-up Back-up Switch Switch On the indoor unit there is a back up on/off switch. The system will operate in the previous mode. Auto Auto Restart Function Restart Power blackout auto restart function records the operational status of the air conditioner immediately prior to being switched off by power supply interruption. The unit automatically resumes operations in that mode and temperature set point after the power has been restored. 12 24-hour ION 24h ION Luminous The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost. Luminous Button With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button. INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat SRK-ZIX series NEW R410A SRK20ZIX-S, SRK25ZIX-S, SRK35ZIX-S SRK50ZIX-S, SRK60ZIX-S SRC20ZIX-S, SRC25ZIX-S, SRC35ZIX-S SRC50ZIX-S, SRC60ZIX-S FUNCTION Allergen SUN Comfortable Functions Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Filter Filter On Timer 24h Timer DRY Others Back-up Auto Switch Restart Swing Auto Convenient & Economy Functions Economy OFF Timer Sleep Refrigerant pipe length Positioning of installation Maximum pipe length Maximum pipe length Maximum height difference Maximum height difference 15m Maintenance & Prevention Functions Self Detachable Diagnostic MC 30m 10m 20m SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S Luminous SRK50ZIX-S SRK60ZIX-S 24h ION ■ SPECIFICATIONS Model ope rat iona l da ta R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C o ol/Heat SRK20ZIX-S SRK25ZIX-S kW 2.0/2.4 2.55/3.00 3.5/4.2 5.0/6.0 6.0/6.8 kW/h 0.3 5/0.435 0.48/0.57 0.845/0.945 1.30/1.35 1.8 6 / 1 . 6 7 3. 2 3 / 4 . 0 7 E E R / C O P C o o l / Heat 5.71/5.52 5.21/5.26 4.14/4.44 3.85/4.44 6/6 6/6 6/6 6/6 4/5.5 C u r re n t C o o l / H e at (MAX) Amp 1.9/2.3 2.4/2.9 4.0/4.5 6.0/6.2 (10) 8.5 / 7 . 7 ( 1 2 ) 39/21 41/22 43/22 45/26 47/26 l/s 192/200 208/217 225/233 225/275 24 2 / 2 8 3 S o u n d P re s s u re Level Hi/Lo Fan A i r f l o w C o o l / H e at Hi Fan kW 3.2 3.4 3.9 6.3 7.0 kW/h 0.96 1.04 1.23 2.06 2.45 3.33 3.27 3.17 3.06 2.86 H2 COP D i m e n s i o n s ( h x wxd) i nd oor SRK 6 0 Z I X - S Stars H2 We i g h t mm kg Filters Drain Hose 309x890x220 15 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1 mm ø 16 P o w e r S o u rc e D i m e n s i o n s ( h x wxd) out door SRK50ZIX-S E n e r g y l a b e l C o ol/Heat H2 Power Input 13 SRK35ZIX-S We i g h t 1 Phase 240V 50Hz mm 590x780(62)x290 kg 38 S o u n d P re s s u re Level S o u n d P o w e r L e vel (AS/NZS1217.4) dB(A) C o m p re s s o r 640x800(71)x2 9 0 43 47 50 48 51 60 63 62 65 Rotary Scroll R e f r i g e r a n t R 4 1 0A kg 1.2 1.4 R e f r i g e r a n t P i p i ng mm ø 6.35/9.52 6.35/12.7 Inverter Heat Pump Model (High COP) Industry leading COP levels Our new models, SRK20/25/35ZIX-S have reached perhaps the highest level of COP (coefficient of performance) in the industry. There was a full model change both of indoor and outdoor units. Our advanced technologies have been applied to our larger models: SRK50/60ZIX-S. 6.0 5.5 5.71 5.41 5.45 5.56 6.0 5.5 6.0 5.00 5.20 5.08 5.26 5.0 5.0 5.0 4.5 4.5 4.5 4.0 4.0 4.0 3.5 3.5 SRK20ZIX-S CURRENT NEW 5.5 4.02 SRK35ZIX-S By applying a movable air inlet panel, minimization of air resistance and advanced design are achieved. Unification of indoor unit design All the ZIX series have the same design for indoor units with a sophisticated flat front panel. Remote control Operation section HI POWER/ECONO button TEMPERATURE button OFF TIMER button ON TIMER button SLEEP button CLEAN switch CANCEL button OPERATION MODE select button ON/OFF (luminous) button AIR FLOW (UP/DOWN) button AIR FLOW (LEFT/RIGHT) button Page 6 3D AUTO button Page 6 ALLERGEN CLEAR button RESET switch The above illustration shows all controls, but in practice only the relevant parts are shown. 14 4.20 3.5 SRK25ZIX-S Movable air inlet panel FAN SPEED button 4.14 4.48 INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat SRF-ZIX series SRC25ZIX-S, SRC35ZIX-S R410A SRC50ZIX-S NEW EER in Cooling The highest COP level in the industry 5.0 Our experience, research and development efforts with the floor standing series have enabled us to reach the highest COP level in the industry. All models clear the 2010 MEPS level by a wide margin. Indoor units are totally new design with optimum balance of air outlet direction and sufficient air flow volume. Enzyme SUN Filter Filter Convenient & Economy Functions Economy OFF Timer Sleep 24h Timer DRY Others Back-up Auto Switch Restart On Timer COP in Heating 4.8 5.0 3.33 4.5 3.9 4.0 FUNCTION Comfortable Functions SRF25ZIX-S, SRF35ZIX-S, SRF50ZIX-S 2.93 3.33 4.0 4.0 3.6 3.5 3.5 3.0 3.0 2.5 Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Air outlet selection 4.7 4.5 3.9 2.93 2.5 SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S Refrigerant pipe length Maintenance & Prevention Functions Self Detachable Diagnostic MC Maximum pipe length Maximum pipe length Maximum height difference Maximum height difference 15m 30m 10m Luminous 20m SRC25ZIX-S SRC35ZIX-S 24h ION SRC50ZIX-S ■ SPECIFICATIONS Model op erat i on al d at a R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C o o l/Heat SRF25ZIX-S SRF35ZIX-S SRF50ZIX - S kW 2.5/3.4 3.5/4.5 5.0/6.0 kW/h 0.521/0.723 0.980/1.124 1.390/1.5 4 0 Ite 4.80/4.70 3.93/4.00 3.60/3.9 0 Po Co He Co He Co He EE CO Co He So E E R / C O P C o o l / Heat E n e r g y l a b e l C o ol/Heat Stars 6/6 6/6 5.5/5.5 C u r re n t C o o l / H e at (MAX) Amp 2.6/3.6 4.1/5.2 6.4/7.1 38/26 39/28 35/30 l/s 150/175 153/178 192/200 S o u n d P re s s u re Level Hi/Lo Fan A i r f l o w C o o l / H e a t Hi Fan H2 H2 Power Input kW 3.6 3.9 6.2 kW/h 1.100 1,270 2.100 3.071 2.952 H2 COP in door D i m e n s i o n s ( h x w xd) We i g h t 3.273 mm kg 660x860x238 18 Filters Drain Hose 19 o ut door 15 We i g h t mm ø 16 Ex (HX 1 Phase 240V 50Hz mm 590x780(62)x290 kg S o u n d P re s s u re Level S o u n d P o w e r L e vel (AS/NZS1217.4) So Natural Enzyme x 1 Photocatalytic Washable x 1 P o w e r S o u rc e D i m e n s i o n s ( h x w xd) S dB(A) C o m p re s s o r Ne Re 640x800(71) x 2 9 0 38 43 47 50 48 60 63 62 Rotary Scroll Refrigerant R410A kg 1.2 1.4 Refrigerant Piping mm ø 6.35/9.52 6.35/12. 7 Re Cle The d Indi * Inverter Heat Pump Model (High COP) Sophisticated Design With a classy semi flat front panel in chic white, the new series fits in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, floor standing or behind gallery installation is available. Quiet Operation The optimum balance of air outlet direction and sufficient air flow volume means the sound level has been minimized. The level of SRF25ZIX-S in the cooling lo mode is 26dB(A) only. Auto air outlet selection Heating operation: Cooling operation: When both lower and upper outlets operation with Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at floor level. When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner. Installation workability Convenient to use operation Piping and drain hose connection can be selected out of 6-directions. Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air flow direction button. Further control can be arranged by a remote control. Right Rear Downward Left rear Left downward 16 Left Inverter Heat Pump Model (High COP) SRK-ZE series R410A SRK63ZE-S1, SRK71ZE-S1 SRK80ZE-S1 Refrigerant pipe length Maximum pipe length SRC63ZE-S1, SRC71ZE-S1 SRC80ZE-S1 30m FUNCTION Allergen SUN Maximum height difference 20m Comfortable Functions SRK63ZE-S1 SRK71ZE-S1 Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Convenient & Economy Functions Economy OFF Timer Sleep Swing On Timer 24h Timer DRY Maintenance & Prevention Functions Self Detachable Diagnostic Others Back-up Auto Switch Restart MC Luminous 24h ION ■ SPECIFICATIONS Model oper ati ona l da ta R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C ool/Heat SRK63ZEA-S1 kW 6.3/7.1 7.1/8.0 8.0/9. 0 1.84/1.86 2.21/2.21 2.84/2. 7 4 2.82/3. 2 9 3.4/3.8 3.2/3.6 E n e r g y l a b e l C ool/Heat Stars 5/5 4.5/4.5 3/3.5 C u r re n t C o o l / Heat (MAX) Amp 8.0/8.1 (12) 9.6/9.6 (14) 12.5/11.7 ( 1 6 ) 43/26 45/26 46/26 l/s 310/350 333/375 350/37 5 S o u n d P re s s u re Level Hi/ULo Fan A i r f l o w C o o l / H eat Hi Fan H2 Power Input kW 7.0 7.3 7.8 kW /h 2.39 2.69 2.98 2.7 2.6 H2 COP i nd oor D i m e n s i o n s ( h xwxd) We i g h t 2.9 mm kg Filters Drain Hose 318x1098x248 15 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1 mm ø 16 P o w e r S o u rc e D i m e n s i o n s ( h xwxd) ou td oor SRK80ZE A - S 1 kW /h E E R / C O P C o o l /Heat H2 17 SRK71ZEA-S1 We i g h t 1 Phase 240V 50Hz mm kg S o u n d P re s s u re Level S o u n d P o w e r Level (AS/NZS1217.4) dB(A) C o m p re s s o r 1 Phase 230 V 5 0 H z 750x880x340 59 47 56 58 58 67 69 Twin Rotary R e f r i g e r a n t R 4 10A kg 1.9 R e f r i g e r a n t P i ping mm ø 6.35/15.88 Inverter Heat Pump Model (High COP) SRK-ZG series R410A SRK20ZG-S, SRK25ZG-S SRK35ZG-S Refrigerant pipe length SRC20ZG-S, SRC25ZG-S SRC35ZG-S Maximum pipe length 15m Maximum height difference FUNCTION Allergen SUN 10m Comfortable Functions SRK20ZG-S, SRK25ZG-S SRK35ZG-S Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Swing Auto Positioning of installation Convenient & Economy Functions Economy OFF Timer Sleep On Timer 24h Timer DRY Maintenance & Prevention Functions Self Detachable Diagnostic MC Others Back-up Auto Switch Restart Luminous 24h ION ■ SPECIFICATIONS Model oper ati ona l da ta R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C o ol/Heat SRK20ZG-S SRK25ZGA-S kW 2.0/2.7 2.5/3.4 3.5/4.2 kW/h 0.44/0.62 0.62/0.93 1.05/1.14 3.33/3.68 4.55/4.35 4.03/3.66 E n e r g y l a b e l C o ol/Heat E E R / C O P C o o l / Heat Stars 6/6 6/5 5/5.5 C u r re n t C o o l / H e at (MAX) Amp 2.2/2.8 2.9/4.1 4.5/4.9 S o u n d P re s s u re Level Hi/Lo Fan A i r f l o w C o o l / H e at Hi Fan H2 H2 Power Input 35/21 l/s 36/22 127/145 kW 3.0 3.7 1.15 1.09 2.6 3.4 i nd oor P o w e r S o u rc e D i m e n s i o n s ( h x wxd) We i g h t Drain Hose We i g h t ou t door 1 Phase 240V 50Hz mm 8.5 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1 mm ø 16 mm 540x780x290 kg S o u n d P re s s u re Level S o u n d P o w e r L e vel (AS/NZS1217.4) 268x790x199 kg Filters D i m e n s i o n s ( h x wxd) 40/23 141/180 kW/h H2 COP 18 SRK35ZGA - S 35 47 dB(A ) 48 58 C o m p re s s o r 62 Rotary R e f r i g e r a n t R 4 1 0A kg R e f r i g e r a n t P i p i ng mm ø 0.9 1.2 6.35/9.52 Cool Only Wall Split System SRK-CHVA series SRK10CHVA Refrigerant pipe length Maximum pipe length 15m SRC10CHVA Maximum height difference 10m SRK10CHVA FUNCTION Comfortable Functions Enzyme SUN Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY Maintenance & Prevention Functions Self Detachable Diagnostic MC Others Back-up Auto Switch Restart 24h ION Luminous ■ SPECIFICATIONS Model o pera ti onal da ta R a t e d C a p a c i t y Cool Power Input Cool SRK10CHVA kW 2.65 kW/h 0.77 EER 3.44 E n e r g y L a b e l C o ol Stars 5 C u r re n t C o o l Amp 3.5 S o u n d P re s s u re Level Hi/Lo Fan Airflow Hi Fan 36/22 l/s o ut door i n door P o w e r S o u rc e Dimensions We i g h t mm kg Filters 268x790x224 8.5 Natural Enzyme x 1, Photocatalytic Washable Deodorising x 1 Drain Hose mm ø 16 Dimensions mm 540x780x290 kg 30 We i g h t S o u n d P o w e r L e vel (AS/NZS1217.4) dB(A ) C o m p re s s o r Refrigerant R22 Refrigerant Piping 19 166 1 Phase 240V 50Hz 58 Rotary kg 0.75 mm ø 6.35/9.52 Control option Wired remote control can be connected Wired remote control can be connected Model Interface SRK63/71/80ZE-S1 SKM60/71ZG-S SRRM, STM not required SRK20~50ZG-S SKM20~50ZG-S SRK20~60ZIX-S SRF25~50ZIX-S interface Remote Control RC-E1R SC-BIK1-E SC-BIKN-E RC-E3 Can be connected to SUPERLINK- II Model SRK20~60ZIX-S SRF25~50ZIX-S Interface SC-BIKN-E SC-ADN-E Remote Control RC-E3 RAC series RAC series (SRK20~60ZIX-S) SC-BIKN-E (SRF25/35/50ZIX-S) PAC VNV series SC-BIKN-E SC-SL2N-E RC-E3 RC-E3 RC-E3 SC-ADN-E SC-ADN-E SC-ADN-E CnT terminal is equipped CnT common output1 (run) output2 (heat) output3 (comp on) output4 (alarm) in put XR1 XR2 XR3 XR4 XR1 XR2 XR3 XR4 XR5 Power source XR5 XR1~4 : DC12v XR5 : 220~240V HOTEL HOTEL Remote surveillance system 20 36 Card key on-off Humidifier linkage Dimensions INDOOR UNIT Unit: mm Wall mounted type SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1 SRK80ZE-S1 881.9 4 21 19 (right,left)61.5 3 248 1098 3 Piping hole right (left) Piping hole right Terminal block 9 9 48 3.1 309 43.5 318 220 890 4 64 55 61.5 46.5 1098 51.2 55 60 60 46.5 61.5 26 Terminal block 122.1 SRK20ZG-S SRK25ZG-S SRK35ZG-S 788 60 27 60 45 45 17.5 199 790 3 9 60 268 Piping hole right(left) Terminal block 45 Floor standing type SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S 840 157.2 85.3 10 22.7 198 100 60 185 55 10 76.3 Screw point fasten the indoor unit(ø5) 804 25.5 238 600 860 6 Outlet for down piping (Refer to the above view) 21 12 60 Outlet for piping (on both side) 15 60 100 125 30.5 55 Dimensions OUTDOOR UNIT Unit: mm SRC20ZG-S SRC25ZG-S SRC35ZG-S Drain holes(ø20) 12 111.4 99.4 290 312.5 350 43.1 23.5 50 313.1 104.9 2-16x12 510 780 14 349.5 439.1 165.1 18.9 61.9 Terminal block Service valve (Liquid) 138.4 Flare connection ø6.35 (1/4'') 95.9 Service valve (Gas) Flare connection ø9.52 (3/8'') Drain holes (ø20.5) 14.8 69.4 327.3 390.6 111.6 510 158.4 89 17.9 780 50.6 12 2-R6 312.5 351.6 43.5 327.3 290 290 312.5 63.4 390.6 83.5 12 24.3 Drain holes(ø20) SRC50ZIX-S SRC60ZIX-S Anchor bolt hole (M10X4places) 351.6 50.6 24.3 SRC20ZIX-S SRC25ZIX-S SRC35ZIX-S 2-15.5 x 12 510 800 17.9 201 14.8 14 40 40 42.5 540 33.5 71.2 61.9 Terminal block Pipe/cable draw-out hole Terminal block 148.4 33.5 61 150 580 880 2-ø15 640 87.9 29.8 Terminal block Service valve(Liquid) 750 165.5 25.5 Flare fitting ø6.35(1/4'') 103.3 24.1 30 48.5 30 22 Service valve(Gas) Flare fitting ø15.88(5/8'') 93 42.5 25.8 150 19 61 418 380 19 Drain holes 12.4 97.7 15.8 532 15 340 47.5 223 60 SRC80ZE-S1 40° Flare connection ø9.52 40° Service valve(gas) Service valve (Liquid) Flare connection ø6.35 (1/4'') Check joint 42.5 Flare connection ø6.35 SRC63ZE-S1 SRC71ZE-S1 33.5 Service valve(liquid) 592.6 138.4 Service valve (Gas) Flare connection ø12.7 (1/2'') Other Products FD series - Inverter Packaged System FDTC FDE FDUM FDT FDC FDU KX6 M series - VRF Inverter Multi System FDCKXEN6 1ø 11.2, 14.0 & 15.5kW (heat pump only) FDCKXES6 3ø 22.4, 28.0 & 33.5kW • 11.2 to 136kW • 2 and 3 pipe VRF systems • Industry leading EER/COP • Reduced footprint outdoors • 69 indoor units available • Power cost distribution • Esolution design tool • 3 year warranty (conditional) • 1000m total pipe run • All compressors are inverter control • BAC net® LonWorks® interfaceWeb Gateway options • New SLA3 colour touch screen controls up to 128 indoors FDCKXES6 3ø 40.0 - 136.0kW 23 Before starting use Heating performance Refrigerant leakage Indication of sound values Use in snowy areas The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well. The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing. Use in oil atmosphere Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break. Use in acidic or alkaline atmosphere If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere. Use in places with high ceilings If the ceiling is high, install a circulator to improve the heat and air flow distribution when heating. The refrigerant (R410A) used for Air conditioner is non-toxic and inflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc. Take the following measures when installing the outdoor unit in snowy areas. ·Snow prevention Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit. ·Snow piling In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit. Automatic defrosting device If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The "Automatic defrosting device" will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again. Servicing the air-conditioner After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist. Safety Precautions Air-conditioner usage target The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur. Before use , Always read the "User s Manual" thoroughly before starting use. Installation Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base. Usage place Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires. ABN 92 133 980 275 National Contact Information: Phone: 1300 138 007 Fax: 1800 644 329 www.mhiaa.com.au Head Office-Sydney Melbourne Branch Brisbane Branch 9C Commercial Road Kingsgrove NSW 2208 PO Box 318 Kingsgrove NSW 1480 Tel: 1300 138 007 Fax: 1800 644 329 10 Derby Street, Collingwood VIC 3066 Tel: +61 3 9419 0699 Fax: +61 3 9419 0788 2/27 Kingtell Place Geebung QLD 4034 PO Box 124, Virginia QLD 4014 Tel: +61 7 3865 8788 Fax: +61 7 3865 6533 MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 ISO9001 ISO14001 Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps). Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the BIWAJIMA PLANT requirements of Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters ISO14001. Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 9001 Certificate number : JQA-0709 MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO., LTD. Certified ISO 9001 Certificate Number : 04100 1998 0813 Certified ISO 14001 Certificate number : JQA-EM0256 ISO 14001 Certificate 04104 1998 0813 E5 MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD. Certificate Number : 04104 1998 0813 E5 MHIAA143_RAC Cat AUG2009 BIWAJIMA PLANT Fax: +61 (0) 2 9600 8044 24 Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.