Motorola MVME712AM Installation guide Download

Transcript
Installation Instructions
2
712M TRANSITION
MODULE
PORT 4
TXD
RXD
RTS
CTS
DTR
DCD
TO MODEM
J19
DB25
TXD
P2-A25
TXD4
P2-A26
RXD4
RXD
P2-A27
RTS4
RTS
P2-A29
CTS4
CTS
P2-A30
DTR4
DTR
P2-A31
DCD4
DCD
DSR
RTXC
P2-A32
RTXC4
TRXC P2-A28
TRXC4
TXC
TO TERMINAL
J18
CABLE
PIN 3
PIN 4
PIN 5
PIN 20
PIN 8
PIN 6
PIN 15
RXC
PIN 17
TXCO
P2
PIN 2
PIN 24
PIN 7
+12V
1.5K
J15
MVME712M EIA-232-D CONFIGURATION (TO TERMINAL)
NOTES:
1. WITH DTE MODULE AND MVME 712 JUMPERED AS TO TERMINAL,
THE CLOCKS (TXC AND RXC) ARE THE WRONG DIRECTION.
THE CLOCKS ARE BOTH INPUTS. THEY SHOULD BOTH BE OUTPUTS.
2. WITH DTE MODULE, THE RECEIVE CLOCK OF 85230 ON B INTERFACE
MUST BE PROGRAMMED AS INPUT TO PREVENT BUFFER CONTENTION.
SIM05
EIA-232-D DTE
Z85230
FRONT PANEL
DB25
B PORT
TXD
RXD
R
RTS
RTS
D
CTS
CTS
R
DTR
DTR
D
DCD
DCD
R
NC
TXC
RXC
TXD
D
RXD
3
4
1
2
DSR
TXC
R
+5V
J12
R
D
RXC
TXCO
PIN 2
PORT 2
PIN 3
PIN 4
PIN 5
PIN 20
PIN 8
PIN 6
MVME 162 EIA-232-D DTE CONFIGURATION
(TO MODEM)
PIN 15
PIN 17
PIN 24
PIN 7
10970.00 (5-6) 9405
Figure 2-3. MVME162 EIA-232-D Connection Diagram, MVME712M (Sheet 5 of 6)
MVME162IG/D2
2-17