Download Siemens SINUMERIK 802D sl Specifications

Transcript
06/2007
Overview of alarms
NCK alarms/ISO alarms
16946
Channel %1 start via START is not allowed
Parameters:
%1 = Channel ID
Definitions:
This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
The machine data $MC_DISABLE_PLC_START specifies which channel is generally started from the
PLC and which channel is only allowed to be started from another channel via the START part program command.
This alarm occurs if the channel was started via the START part programm command and
$MC_DISABLE_PLC_START==FALSE was set.
Reaction:
Alarm display.
Remedy:
Modify $MC_DISABLE_PLC_START of switch off "Group Serupro" (see $MC_SERUPRO_MODE).
Program Continuation:
Clear alarm with the Delete key or NC START.
16947
Channel %1 start via PLC is not allowed
Parameters:
%1 = Channel ID
Definitions:
This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
The machine data $MC_DISABLE_PLC_START specifies which channel is generally started from the
PLC and which channel is only allowed to be started from another channel via the START part program command.
This alarm occurs if the channel was started via the PLC and $MC_DISABLE_PLC_START==TRUE
was set.
Reaction:
Alarm display.
Remedy:
Modify $MC_DISABLE_PLC_START of switch off "Group Serupro" (see $MC_SERUPRO_MODE).
Program Continuation:
Clear alarm with the Delete key or NC START.
16948
Channel %1 dependent channel %2 still active
Parameters:
%1 = Channel ID
%2 = Channel ID
Definitions:
This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
A _dependent channel_ is a channel that had indirectly been started by the currently active channel.
The currently active channel was started via PLC.
This channel m_u_s_t be terminated (i.e. reached M30) before the current channel is terminated.
This alarm occurs if the currently active channel is terminated before the dependent channel.
Reaction:
Alarm display.
Remedy:
Switch off "Group Serupro" (see $MC_SERUPRO_MODE) or install WAITE.
Program Continuation:
Clear alarm with the Delete key or NC START.
16949
Correspondence between marker of channel %1 and channel %2 is
invalid.
Parameters:
%1 = Channel ID
%2 = Channel ID
Definitions:
This channel defines a WAIT marker with other channels, which on their part have no correspondence
with this wait marker.
This channel's WAIT marker has no explicit counterpart in the other channel; i.e. the channels do not
mutually wait.
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
2-193