Download Siemens SINUMERIK 802D sl Specifications

Transcript
06/2007
Overview of alarms
NCK alarms/ISO alarms
17650
Channel %1 block %2 machine axis %3 not programmable
Parameters:
%1 = channel number
%2 = block number, label
%3 = axis name, spindle number
Definitions:
The machine axis cannot be used when a transformation is active. It might be possible to program the
function in a different coordinate system. The axis identifier is used to select the coordinate system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Deactivate the transformation or use another coordinate system.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
17800
Channel %1 block %2 illegally coded position programmed
Parameters:
%1 = channel number
%2 = block number, label
Definitions:
The position number n specified with the vocabulary word FP=n is not permissible. Two absolute axis
positions can be defined as fixed points via the axis-specific MD30 600 FIX_POINT_POS [n].
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program vocabulary word FP with machine fixed points 1 or 2.
Example:
Approach fixed point 2 with machine axes X1 and Z2.
N100 G75 FP=2 X1=0 Z2=0
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
17900
Channel %1 block %2 axis %3 is no machine axis
Parameters:
%1 = channel number
%2 = block number, label
%3 = axis name, spindle number
Definitions:
At this point, the block context calls for a machine axis. This is the case with:
• G74 (reference point approach)
• G75 (fixed point approach)
If a geometry or additional axis identifier is used, then it must also be allowed as machine axis identifier
(MD 10000 AXCONF_MACHAX_NAME_TAB).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use machine axis identifier when programming.
Program Continuation:
Clear alarm with the RESET key. Restart part program
18000
Channel %1 block %2 NCK-specific protection zone %3 wrong. Error
code %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of NCK protection zone
%4 = Error specification
Definitions:
There is an error in the definition of the protection zone. The error number gives the specific reason
for the alarm. The following meanings apply:
1: Incomplete or conflicting contour definition.
2: Contour encompasses more than one surface area.
3: Tool-related protection zone is not convex.
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
2-209