Download Siemens SINUMERIK 802D sl Specifications

Transcript
2.2
61000
Cycle alarms
Channel %1 block %2: No tool offset active
Parameters:
Definitions:
Source (cycle):
SLOT1, SLOT2
POCKET3, POCKET4
CYCLE71
CYCLE72
CYCLE93 to CYCLE95
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
A tool must be programmed with corrections in the program called up.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61001
Channel %1 block %2: Thread lead incorrectly defined
Parameters:
Definitions:
Source (cycle):
CYCLE84
CYCLE840
CYCLE97
CYCLE376T
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameters for thread size and check pitch information (contradict each other)
Program Continuation:
Clear alarm with the RESET key. Restart part program
61002
Channel %1 block %2: Type of machining incorrectly defined
Parameters:
Definitions:
Source (cycle):
SLOT1, SLOT2
POCKET3, POCKET4
CYCLE71
CYCLE72
CYCLE93
CYCLE95
CYCLE97
Remedy:
The machining type parameter VARI has been set to the wrong value and needs to be altered.
Program Continuation:
Clear alarm with the RESET key. Restart part program
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition