Overview of alarms
Cycle alarms
61269
Channel %1 block %2: External tool diameter too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Incorrect tool definition.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check angle and diameter of the tool used.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61270
Channel %1 block %2: Chamfer width too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Chamfer width selected too small.
Alarm triggered by the following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the chamfer width.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61271
Channel %1 block %2: Chamfer width > tool radius
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Chamfer width larger than tool radius.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a larger tool.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61272
Channel %1 block %2: Insertion depth too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Insertion depth on chamfering too small.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the insertion depth.
Program Continuation:
Clear alarm with the RESET key. Restart part program